Search NASA⌕ Search

SEARCH · Search NASA

Results for “threshold based”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,675 records · Page 93

Systems and methods for designing new materials for superlubricity

A method for designing new materials for superlubricity comprises developing, on a computational system, a computational supercell comprising x unit cells of a base material, each unit cell comprising y atoms of the base material. The computational system replaces randomly chosen z atoms of the base material with an impurity atom of an impurity material to form a candidate material. The computational system determines volumetric strain of the candidate material. In response to the volumetric strain exceeding a predetermined threshold, the computational system determines that the candidate material has superlubricity. The computational system displays the candidate material to a user if the candidate material has superlubricity.

Narayanan, Badri↗

Ne 21 energy levels approaching the α -particle threshold

Nuclei around Ne 20 exhibit an interplay of different excitations caused by different aspects of nuclear structure, including single-particle and multiparticle configurations and collective rotations. One-nucleon transfer reactions selectively probe single-particle structures in these nuclei. These nuclei are also important to astrophysics, with a number of important reactions proceeding through this mass region. Energy levels approaching the α -particle threshold in Ne 21 are of importance to nuclear structure. The Ne 20 ( d , p ) Ne 21 reaction was measured and the corresponding spectroscopic nuclear information was extracted. States in Ne 21 were populated using the Ne 20 ( d , p ) Ne 21 reaction in forward kinematics. Protons were identified in the Triangle Universities Nuclear Laboratory (TUNL) Enge split-pole spectrograph and angular distributions were extracted. Spin-party assignments were made and neutron partial widths were determined based on distorted-wave Born approximation (DWBA) analysis. Several new energy levels were observed at energies of 7176, 7235, 7250, and 7337 keV, and spin-parities are reported which generally agree with previous results where literature was available. Spin and parity assignments are reported for several energy levels along with estimated neutron widths for those states above the neutron threshold ( S n = 6761 keV ). Results from this study are placed in context with a review of the available literature on all known states in this energy region of Ne 21 . Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of On-Board kV Cone Beam Computed Tomography–Based Dose Calculation With Deformable Image Registration Using Hounsfield Unit Modifications

Purpose: The purpose of this study was to estimate the accuracy of the dose calculation of On-Board Imager (Varian, Palo Alto, CA) cone beam computed tomography (CBCT) with deformable image registration (DIR), using the multilevel-threshold (MLT) algorithm and histogram matching (HM) algorithm in pelvic radiation therapy. Methods and Materials: One pelvis phantom and 10 patients with prostate cancer treated with intensity modulated radiation therapy were studied. To minimize the effect of organ deformation and different Hounsfield unit values between planning CT (PCT) and CBCT, we modified CBCT (mCBCT) with DIR by using the MLT (mCBCT{sub MLT}) and HM (mCBCT{sub HM}) algorithms. To evaluate the accuracy of the dose calculation, we compared dose differences in dosimetric parameters (mean dose [D{sub mean}], minimum dose [D{sub min}], and maximum dose [D{sub max}]) for planning target volume, rectum, and bladder between PCT (reference) and CBCTs or mCBCTs. Furthermore, we investigated the effect of organ deformation compared with DIR and rigid registration (RR). We determined whether dose differences between PCT and mCBCTs were significantly lower than in CBCT by using Student t test. Results: For patients, the average dose differences in all dosimetric parameters of CBCT with DIR were smaller than those of CBCT with RR (eg, rectum; 0.54% for DIR vs 1.24% for RR). For the mCBCTs with DIR, the average dose differences in all dosimetric parameters were less than 1.0%. Conclusions: We evaluated the accuracy of the dose calculation in CBCT, mCBCT{sub MLT}, and mCBCT{sub HM} with DIR for 10 patients. The results showed that dose differences in D{sub mean}, D{sub min}, and D{sub max} in mCBCTs were within 1%, which were significantly better than those in CBCT, especially for the rectum (P<.05). Our results indicate that the mCBCT{sub MLT} and mCBCT{sub HM} can be useful for improving the dose calculation for adaptive radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-infrared InAs-based quantum cascade lasers operating at 291 K (λ=19 μm) with metal-metal resonators

We demonstrate quantum cascade lasers in the InAs/AlSb material system emitting at wavelengths of λ = 19 μm and λ = 21 μm. The maximum operating temperatures are 291 K and 250 K, and the threshold current densities at 78 K are as low as 0.6 kA/cm{sup 2} and 1.3 kA/cm{sup 2} for the lasers emitting at λ = 19 μm and λ = 21 μm, respectively. These values represent the best performance to date for quantum cascade lasers operating above λ = 16 μm. Although the devices employ metal-metal waveguide geometries, the diffraction effects which typically hinder the output beam of THz devices are not observed.

36 MATERIALS SCIENCE↗

Ultrafast and ultrasensitive hydrogen sensors based on self-assembly monolayer promoted 2-dimensional palladium nanoclusters

A device and method of making same. The device or hydrogen detector has a non-conducting substrate with a metal film capable of absorbing hydrogen to form a stable metal hydride. The metal film is on the threshold of percolation and is connected to mechanism for sensing a change in electrical resistance in response to the presence of hydrogen in contact with the metal film which causes an increase in conductivity.

47 OTHER INSTRUMENTATION↗

Search for lightly ionizing particles in superCDMS and simulation of neutron backgrounds

The Super Cryogenic Dark Matter Search (SuperCDMS) is a direct-detection dark matter search experiment that primarily aims to search for Weakly Interacting Massive Particles (WIMPs) using state-of-the-art solid-state detection technology. During its operation at the Soudan underground laboratory, germanium detectors were operated with high bias voltage mode known as the CDMS low ionization threshold experiment (CDMSlite) to achieve below-keV thresholds. CDMSlite, for being able to measure small energy depositions in detectors, also provides sensitivity to Lightly Ionizing Particles (LIPs) with very small fractional charges. This thesis will discuss an analysis to search LIPs with the data acquired in CDMSlite mode. An important component for LIPs search is the expected energy-deposition distributions for LIPs falling on the CDMSlite detector. In this thesis, a simulation framework to calculate the energy-deposition distributions is developed. This thesis presents first direct-detection limits on the intensity of cosmogenic LIPs with electric charges smaller than e/(3 × 105) as well as the strongest limits for charges ≤ e/160, with a minimum intensity of 1.36 × 10-7 cm-2s-1sr-1 at charge e/160.In any rare-event search experiment, understanding background is crucial. Neutrons capable of mimicking dark matter signals are a major background for any dark matter search experiment. A simulationmore » study to estimate the neutron background for an India based dark matter search experiment at Jaduguda Underground Science Laboratory (JUSL) is performed. The experiment at JUSL will be the first phase of a proposed Dark matter search at India-based Neutrino Observatory (DINO). It will be a direct detection experiment with primary aims to search for WIMPs as dark matter candidates. In this thesis, we discuss the methodology of estimating neutron flux at JUSL and report the results. The total neutron flux reaching the laboratory above 1 MeV energy threshold is found to be 5.76(±0.69) × 10-6 cm-2s-1. The impact of neutron background on the sensitivity of the experiment to detect dark matter at JUSL is also discussed. The thesis is organized as follows. Chapter 1 provides a brief introduction to the Lightly Ionizing Particle (LIPs). The analysis to search LIPs in SuperCDMS is briefly outlined in the chapter. This chapter also discusses the importance of neutron background estimates in a dark matter search experiment, more specifically, in the context of a proposed India-based dark matter search experiment at Jaduguda Underground Science Laboratory. In Chapter 2, the SuperCDMS experiment is introduced. In Chapter 3, the framework developed to perform simulations for Lightly Ionizing Particles is presented. In Chapter 4, the LIPs search analysis with the CDMSlite data and the results are discussed. In Chapter 5, the simulation of neutron background and the feasibility of dark-matter search at JUSL is discussed. Finally, conclusions from all the results discussed in this thesis are presented in Chapter 6.« less

Banik, Samir↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Search for Lightly Ionizing Particles in SuperCDMS and simulation of neutron backgrounds

The Super Cryogenic Dark Matter Search (SuperCDMS) is a direct-detection dark matter search experiment that primarily aims to search for Weakly Interacting Massive Particles (WIMPs) using state-of-the-art solid-state detection technology. During its operation at the Soudan underground laboratory, germanium detectors were operated with high bias voltage mode known as the CDMS low ionization threshold experiment (CDMSlite) to achieve below-keV thresholds. CDMSlite, for being able to measure small energy depositions in detectors, also provides sensitivity to Lightly Ionizing Particles (LIPs) with very small fractional charges. This thesis will discuss an analysis to search LIPs with the data acquired in CDMSlite mode. An important component for LIPs search is the expected energy-deposition distributions for LIPs falling on the CDMSlite detector. In this thesis, a simulation framework to calculate the energy-deposition distributions is developed. This thesis presents first direct-detection limits on the intensity of cosmogenic LIPs with electric charges smaller than e /(3 × 10 5 ) as well as the strongest limits for charges ≤ e /160, with a minimum intensity of 1.36 × 10 -7 cm -2 s -1 sr -1 at charge e /160.In any rare-event search experiment, understanding background is crucial. Neutrons capable of mimicking dark matter signals are a major background for any dark matter search experiment. A simulation study to estimate the neutron background for an India based dark matter search experiment at Jaduguda Underground Science Laboratory (JUSL) is performed. The experiment at JUSL will be the first phase of a proposed Dark matter search at India-based Neutrino Observatory (DINO). It will be a direct detection experiment with primary aims to search for WIMPs as dark matter candidates. In this thesis, we discuss the methodology of estimating neutron flux at JUSL and report the results. The total neutron flux reaching the laboratory above 1 MeV energy threshold is found to be 5.76(±0.69) × 10 -6 cm -2 s -1 . The impact of neutron background on the sensitivity of the experiment to detect dark matter at JUSL is also discussed. The thesis is organized as follows. Chapter 1 provides a brief introduction to the Lightly Ionizing Particle (LIPs). The analysis to search LIPs in SuperCDMS is briefly outlined in the chapter. This chapter also discusses the importance of neutron background estimates in a dark matter search experiment, more specifically, in the context of a proposed India-based dark matter search experiment at Jaduguda Underground Science Laboratory. In Chapter 2, the SuperCDMS experiment is introduced. In Chapter 3, the framework developed to perform simulations for Lightly Ionizing Particles is presented. In Chapter 4, the LIPs search analysis with the CDMSlite data and the results are discussed. In Chapter 5, the simulation of neutron background and the feasibility of dark-matter search at JUSL is discussed. Finally, conclusions from all the results discussed in this thesis are presented in Chapter 6.

Banik, Samir↗

Study of carbonaceous nanoparticles in premixed C{sub 2}H{sub 4}-air flames and behind a spark ignition engine

Nanoparticle size distributions and their concentrations were studied in atmospheric premixed ethylene/air flames using photo ionization mass spectrometry (PIMS) and total organic carbon (TOC) calibration supplemented by differential mobility analysis (DMA). Focus of this study is the evolution of nanoparticles as a function of height above burner (HAB) and of the C/O ratio of the unburned gases. It was found that especially particles of the cluster type exhibit a sharp concentration drop by more than two orders of magnitude within a narrow C/O window which is close to the sooting threshold. Using DMA a decline by two orders of magnitude was found. These results suggest that at best only small concentrations of nanoparticles should be formed significantly below the sooting threshold. As these conditions prevail in a homogeneously charged IC engine no or only very small nanoparticle emissions are expected in the exhaust gas. This was indeed found for a small Otto engine driving a power generator unit. Using flame nanoparticle profiles as standard, absolute concentrations for their emissions could be deduced. These data were supported by additional DMA measurements. The calibration using TOC did not completely match the one based on the condensation particle counter of the DMA apparatus. (author)

33 ADVANCED PROPULSION SYSTEMS↗

Phosphodiesterase (PDE5) inhibition assay for rapid detection of erectile dysfunction drugs and analogs in sexual enhancement products

Abstract Products marketed as dietary supplements for sexual enhancement are frequently adulterated with phosphodiesterase‐5 (PDE5) inhibitors, which are erectile dysfunction drugs or their analogs that can cause adverse health effects. Due to widespread adulteration, a rapid screening assay was developed to detect PDE5 inhibitors in adulterated products. The assay employs fluorescence detection and is based on measuring inhibition of PDE5 activity, the pharmacological mechanism shared among the adulterants. Initially, the assay reaction scheme was established and characterized, followed by analysis of 9 representative PDE5 inhibitors ( IC 50 , 0.4–4.0 ng mL –1 ), demonstrating sensitive detection in matrix‐free solutions. Next, dietary supplements serving as matrix blanks ( n = 25) were analyzed to determine matrix interference and establish a threshold value; there were no false positives. Finally, matrix blanks were spiked with 9 individual PDE5 inhibitors, along with several mixtures. All 9 adulterants were successfully detected (≤ 5 % false negative rate; n = 20) at a concentration of 1.00 mg g –1 , which is over 5 times lower than concentrations commonly encountered in adulterated products. A major distinction of the PDE5 inhibition assay is the ability to detect adulterants without prior knowledge of their chemical structures, demonstrating a broad‐based detection capability that can address a continuously evolving threat of new adulterants. The PDE5 inhibition assay can analyze over 40 samples simultaneously within 15 minutes and involves a single incubation step and simple data analysis, all of which are advantageous for combating the widespread adulteration of sex‐enhancement products.

Santillo, Michael F.↗

Health impact assessment in planning: Development of the design for health HIA tools

How can planners more systematically incorporate health concerns into practical planning processes? This paper describes a suite of health impact assessment tools (HIAs) developed specifically for planning practice. Taking an evidence-based approach the tools are designed to fit into existing planning activities. The tools include: a short audit tool, the Preliminary Checklist; a structured participatory workshop, the Rapid HIA; an intermediate health impact assessment, the Threshold Analysis; and a set of Plan Review Checklists. This description provides a basis for future work including assessing tool validity, refining specific tools, and creating alternatives.

20 FOSSIL-FUELED POWER PLANTS↗

Estimating Black Carbon Aging Time-Scales with a Particle-Resolved Aerosol Model

Understanding the aging process of aerosol particles is important for assessing their chemical reactivity, cloud condensation nuclei activity, radiative properties and health impacts. In this study we investigate the aging of black carbon containing particles in an idealized urban plume using a new approach, the particleresolved aerosol model PartMC-MOSAIC. We present a method to estimate aging time-scales using an aging criterion based on cloud condensation nuclei activation. The results show a separation into a daytime regime where condensation dominates and a nighttime regime where coagulation dominates. For the chosen urban plume scenario, depending on the supersaturation threshold, the values for the aging timescales vary between 0.06 hours and 10 hours during the day, and between 6 hours and 20 hours during the night.

54 ENVIRONMENTAL SCIENCES↗

A Risk-Based Sensor Placement Methodology

A risk-based sensor placement methodology is proposed to solve the problem of optimal location of sensors or detectors to protect population against the exposure to and effects of known and/or postulated chemical, biological, and/or radiological threats. Risk is calculated as a quantitative value representing population at risk from exposure against standard exposure levels. Historical meteorological data are used to characterize weather conditions as the frequency of wind speed and direction pairs. The meteorological data drive atmospheric transport and dispersion modeling of the threats, the results of which are used to calculate risk values. Sensor locations are determined via an iterative dynamic programming algorithm whereby threats captured or detected by sensors placed in prior stages are removed from consideration in subsequent stages. In addition to the risk-based placement algorithm, the proposed methodology provides a quantification of the marginal utility of each additional sensor or detector. Thus, the criterion for halting the iterative process can be the number of detectors available, a threshold marginal utility value, or the cumulative detection of a minimum factor of the total risk value represented by all threats. The methodology quantifies the effect of threat reduction measures, such as reduced probability of one or more threats due to administrative and/or engineering controls.

sensor placement risk↗

Magnetic and X-ray Diagnostics for Plasma Position Measurements in the Ignition Experiment Ignitor

The ignition experiment Ignitor will produce high performance plasma regimes with neutron fluxes at the first wall comparable to those expected in power generating reactors (10{sup 15} n/ cm{sup 2}/ s at the first wall). An appreciable degradation of the inorganic insulators surrounding the conductors is expected and the measurement of basic plasma parameters, such as plasma current and position, by electromagnetic diagnostics can become problematic. Thus an R and D program, aimed at the development of effective and affordable devices for electromagnetic diagnostics with higher damage threshold, is being carried out. Prototype diagnostic coils of different shapes have been manufactured, in collaboration with SALENTEC and Universita di Lecce. At the same time, an alternative plasma position control method is being explored, based on the diffraction and detection of the soft X-ray radiation emitted, mostly by Molybdenum impurities, near the top or bottom of the plasma column, where the distance of the plasma last closed magnetic surface from the wall is only few millimeters. The underlying principles and general layout of the new system is essentially an adaptation of a 2-dimensional curved crystal spectrometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy window stochastic density functional theory

We report that linear scaling density functional theory is important for understanding electronic structure properties of nanometer scale systems. Recently developed stochastic density functional theory can achieve linear or even sublinear scaling for various electronic properties without relying on the sparsity of the density matrix. The basic idea relies on projecting stochastic orbitals onto the occupied space by expanding the Fermi-Dirac operator and repeating this for N χ stochastic orbitals. Often, a large number of stochastic orbitals are required to reduce the statistical fluctuations (which scale as N$-1/2\atop{χ}$) below a tolerable threshold. In this work, we introduce a new stochastic density functional theory that can efficiently reduce the statistical fluctuations for certain observable and can also be integrated with an embedded fragmentation scheme. The approach is based on dividing the occupied space into energy windows and projecting the stochastic orbitals with a single expansion onto all windows simultaneously. This allows for a significant reduction of the noise as illustrated for bulk silicon with a large supercell. Finally, we also provide theoretical analysis to rationalize why the noise can be reduced only for a certain class of ground state properties, such as the forces and electron density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pulsed electron-beam-pumped laser based on AlGaN/InGaN/GaN quantum-well heterostructure

The parameters of pulsed blue-violet (λ ≈ 430 nm at T = 300 K) lasers based on an AlGaN/InGaN/GaN structure with five InGaN quantum wells and transverse electron-beam pumping are studied. At room temperature of the active element, the minimum electron energy was 9 keV and the minimum threshold electron beam current density was 8 A cm{sup -2} at an electron energy of 18 keV. (lasers)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser adaptive holographic hydroacoustic intensimeter

A new type of a vector hydrophone, a laser adaptive hydroacoustic intensimeter, is investigated. Two identical, spatially separated coil-type sensors are used as a primary receiver of the acoustic signal. The signals received at the sensor output are phase demodulated in a two-channel adaptive holographic interferometer based on two dynamic holograms multiplexed in a CdTe photorefractive crystal. Using a laser intensimeter, the acoustic field formed in a limited volume is studied. The performance characteristics of the intensimeter are determined experimentally; its threshold sensitivity, according to the acoustic field intensity, constitutes 0.1 × 10{sup −13} W m{sup −2}. (laser applications)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗