Search NASA⌕ Search

SEARCH · Search NASA

Results for “Absorption columns”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Retrieval and Analysis of Stratospheric NO2 from GOME

In this paper we describe the retrieval of stratospheric NO2 from the GOME (Global Ozone Monitoring Experiment) spectrometer. For this retrieval the Differential Optical Absorption Spectroscopy (DOAS) is used and we describe the influence of the instrument s characteristics on this measurement technique. This analysis led to an improved version of the DOAS algorithm resulting in results with lower systematic errors. Subsequently these results were used to separate the tropospheric and stratospheric fraction of the measured NO;! in the atmosphere. This paper is focusing on the annual variations of the stratospheric distribution of nitrogen oxides. For this examination the satellite data from beginning of 1996 to the end of 2001 was used and has been visualized in a plot zonal means versus time of the year, a visualization which proved to be very useful for Ozone. Additionally the so called "Noxon Cliff", a drop of NO2 column densities Noxon measured in 1975-77 while traveling northwards towards the pole in Canada, is shown. Also its southern equivalent could be discovered in the GOME data.

Wenig, M.↗

Effects of gas–wall partitioning in Teflon tubing and instrumentation on time-resolved measurements of gas-phase organic compounds

Recent studies have demonstrated that organic compounds can partition from the gas phase to the walls in Teflon environmental chambers and that the process can be modeled as absorptive partitioning. Here these studies were extended to investigate gas–wall partitioning of organic compounds in Teflon tubing and inside a proton-transfer-reaction mass spectrometer (PTR-MS) used to monitor compound concentrations. Rapid partitioning of C 8 –C 14 2-ketones and C 11 –C 16 1-alkenes was observed for compounds with saturation concentrations ( c * ) in the range of 3 × 10 4 to 1 × 10 7 µg m -3 , causing delays in instrument response to step-function changes in the concentration of compounds being measured. These delays vary proportionally with tubing length and diameter and inversely with flow rate and c * . The gas–wall partitioning process that occurs in tubing is similar to what occurs in a gas chromatography column, and the measured delay times (analogous to retention times) were accurately described using a linear chromatography model where the walls were treated as an equivalent absorbing mass that is consistent with values determined for Teflon environmental chambers. The effect of PTR-MS surfaces on delay times was also quantified and incorporated into the model. The model predicts delays of an hour or more for semivolatile compounds measured under commonly employed conditions. These results and the model can enable better quantitative design of sampling systems, in particular when fast response is needed, such as for rapid transients, aircraft, or eddy covariance measurements. They may also allow estimation of c * values for unidentified organic compounds detected by mass spectrometry and could be employed to introduce differences in time series of compounds for use with factor analysis methods. Best practices are suggested for sampling organic compounds through Teflon tubing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

OPTICALLY THICK H I DOMINANT IN THE LOCAL INTERSTELLAR MEDIUM: AN ALTERNATIVE INTERPRETATION TO ''DARK GAS''

Dark gas in the interstellar medium (ISM) is believed to not be detectable either in CO or H I radio emission, but it is detectable by other means including γ rays, dust emission, and extinction traced outside the Galactic plane at |b| > 5°. In these analyses, the 21 cm H I emission is usually assumed to be completely optically thin. We have reanalyzed the H I emission from the whole sky at |b| > 15° by considering temperature stratification in the ISM inferred from the Planck/IRAS analysis of the dust properties. The results indicate that the H I emission is saturated with an optical depth ranging from 0.5 to 3 for 85% of the local H I gas. This optically thick H I is characterized by spin temperature in the range 10 K-60 K, significantly lower than previously postulated in the literature, whereas such low temperature is consistent with emission/absorption measurements of the cool H I toward radio continuum sources. The distribution and the column density of the H I are consistent with those of the dark gas suggested by γ rays, and it is possible that the dark gas in the Galaxy is dominated by optically thick cold H I gas. This result implies that the average density of H I is 2-2.5 times higher than that derived on the optically thin assumption in the local ISM.

79 ASTRONOMY AND ASTROPHYSICS↗

CO 2 Capture with Ionic Liquids Involving Phase Change (Final Report)

Coal-fired power plants provide nearly 50% of all electricity in the U.S. While coal is a cheap and abundant natural resource, its continued use contributes to rising carbon dioxide (CO 2 ) levels in the atmosphere. Capturing and storing this CO 2 would reduce atmospheric greenhouse gas levels while allowing power plants to continue using inexpensive coal. Carbon capture and storage represents a significant cost to power plants that must retrofit their existing facilities to accommodate new technologies. Reducing these costs is the primary objective of ARPA-E's carbon capture program. Researchers at the University of Notre Dame and their partners at Matric developed a new CO 2 capture process that uses materials that we call Phase Change Ionic Liquids (PCILs). PCILs are solid at the temperature of the CO 2 absorption but change to liquid when they bind with CO 2 . The PCILs have a high capacity for CO 2 at post-combustion flue gas pressures and temperatures because of a chemical reaction between the CO 2 and the PCIL. Upon heating, the CO 2 is released, and the PCILs re-solidify. The heat released in the solidification process reduces the amount of external heat that must be added. As with conventional CO 2 capture processes, the PCIL process has an absorber and a regenerator. Computer simulation of the process enabled calculation of viable process conditions and power needs. The main concepts of the process were demonstrated using lab-scale apparatus. Capture of CO 2 was carried out using a sieve tray column in continuous mode. Desorption of the CO 2 in the regenerator occurred while the liquid droplets solidified. The key to making this process viable was the use of a mixture of the complexed liquid with the unreacted solid particles in the absorber. This mixture formed a well-behaved slurry that flowed readily. Therefore, handling of solid particles is avoided in the process. Parasitic power was decreased by 55% from the amount required by the monoethanolamine (MEA) process. For the PCIL process, parasitic power is only 23% of the net power generated by the plant, which is remarkably close to the 19% DOE target. The capital cost for the CO 2 capture unit is higher for the PCIL process than the MEA process. Nonetheless, the overall increase in the cost of electricity (COE) is dramatically lower - only 4.1¢/kWh for the PCIL process compared with 5.7¢/kWh for the MEA process. The cost of CO 2 avoided is $48/ton of CO 2 . As a result, we conclude that CO 2 capture with phase change ionic liquids is an exceedingly promising technology.

01 COAL, LIGNITE, AND PEAT↗

COSMIC ORIGINS SPECTROGRAPH AND FUSE OBSERVATIONS OF T {approx} 10{sup 5} K GAS IN A NEARBY GALAXY FILAMENT

We present a clear detection of a broad Ly{alpha} absorber (BLA) with a matching O VI line in the nearby universe. The BLA is detected at z(Ly{alpha})=0.01028 in the high signal-to-noise ratio spectrum of Mrk 290 obtained using the Cosmic Origins Spectrograph. The Ly{alpha} absorption has two components, with b(H i) = 55{+-}1 km s{sup -1} and b(H i) = 33{+-}1 km s{sup -1}, separated in velocity by v {approx} 115 km s{sup -1}. The O VI, detected by the Far-Ultraviolet Spectroscopic Explorer at z(O vi) = 0.01027, has a b(O vi) = 29{+-}3 km s{sup -1} and is kinematically well aligned with the broader H I component. The non-detection of other ions such as C II, Si II, Fe II, C III, Si III, C IV, Si IV, and N V at the same velocity as the BLA and the O VI implies that the absorber is tracing highly ionized gas. The different line widths of the BLA and O VI suggest a temperature of T = 1.4 x 10{sup 5} K in the absorber. Photoionization, collisional ionization equilibrium as well as non-equilibrium collisional ionization models do not explain the ion ratios at this temperature. The observed line strength ratios and line widths favor an ionization scenario in which both ion-electron collisions and UV photons contribute to the ionization in the gas. Such a model requires a low metallicity of {approx}-1.7 dex, ionization parameter of log U {approx} -1.4, a large total hydrogen column density of N(H) {approx} 4 x 10{sup 19} cm{sup -2}, and a path length of {approx}400 kpc. The line of sight to Mrk 290 intercepts at the redshift of the absorber, a megaparsec scale filamentary structure extending over {approx}20{sup 0} in the sky, with several luminous galaxies distributed within {approx}1.5 h {sup -1} Mpc projected distance from the absorber. The collisionally ionized gas phase of this absorber is most likely tracing a shock-heated gaseous structure, consistent with a few different scenarios for the origin including an overdense region of the warm-hot intergalactic medium in the galaxy filament or highly ionized gas in the extended halo of one of the galaxies in the filament. In general, BLAs with metals provide an efficient means to study T {approx} 10{sup 5}-10{sup 6} K gas in galaxy halos and in the intergalactic medium. A substantial fraction of the baryons missing from the present universe is predicted to be in such environments in the form of highly ionized plasma.

79 ASTRONOMY AND ASTROPHYSICS↗

Absorption in Extended Inhomogeneous Clouds

The launch of several different sensors, including CloudSat, into the A-train constellation of satellites allows us for the first time to compute absorption that can occur in realistic vertically inhomogeneous clouds including multiple cloud decks. CloudSat data show that these situations are common. Therefore, understanding vertically inhomogeneous clouds is important from both climate and satellite atmospheric composition remote sensing perspectives. Satellite passive sensors that operate from the near IR to the UV often rely on radiative cloud pressures derived from absorption in oxygen bands (A, B, gamma, or O2-O2 bands) or from rotational-Raman scattering in order to retrieve information about atmospheric trace gases. The radiative cloud pressure is distinct from the physical cloud top derived from thermal infrared measurements. Therefore, the combination of information from different passive sensors yields some information about the cloud vertical profile. When either or both the clouds or atmospheric absorbers (trace gases and aerosols) are vertically inhomogeneous, the use of an effective cloud pressure derived from these approaches may lead to errors. Here, we focus on several scenarios (deep convective clouds and distinct two layer clouds) based on realistic cloud optical depth vertical profiles derived from the CloudSatfMODIS combination. We focus on implications for trace-gas column amount retrievals (specifically ozone and NO2) and derived surface UV irradiance from the Ozone Monitoring Instrument (OMI) on the Atrain Aura platform.

Joiner, Joanna↗

Characterization of Aerosols over the Indochina Peninsula from Satellite-Surface Observations During Biomass Burning Pre-Monsoon Season

This paper presents characterization of aerosols over the Indochina peninsular regions of Southeast Asia during pre-monsoon season from satellite and ground-based radiometric observations. Our analysis focuses on the seasonal peak period in aerosol loading and biomass burning, prior to the onset of the Asian summer monsoon, as observed in the inter-annual variations of Aerosol Optical Depth (AOD) and fire count data from MODIS. Multi-year (2007-2011) analysis of spaceborne lidar measurements, from CALIOP, indicates presence of aerosols mostly within boundary layer, however extending to elevated altitudes to approx. 4 km over northern regions of Indochina, encompassing Myanmar, northern Thailand and southern China. In addition, a strong gradient in aerosol loading and vertical distribution is observed from the relatively clean equatorial conditions to heavy smoke-laden northern regions (greater aerosol extinction and smaller depolarization ratio). Based on column-integrated ground-based measurements from four AERONET locations distributed over Thailand, the regional aerosol loading is found to be significantly absorbing with spectral single scattering albedo (SSA) below 0.91+/-0.02 in the 440-1020 nm range, with lowest seasonal mean SSA (most absorbing aerosol) over the northern location of Chiang Mai (SSA approx. 0.85) during pre-monsoon season. The smoke-laden aerosol loading is found to exhibit a significant diurnal pattern with higher AOD departures during early morning observations relative to late afternoon conditions (peak difference of more than 15% amplitude). Finally, satellite-based aerosol radiative impact is assessed using CERES shortwave Top-of-Atmosphere flux, in conjunction with MODIS AOD. Overall, a consistency in the aerosol-induced solar absorption characteristic is found among selected regions from ground-based sunphotometer-derived spectral SSA retrievals and satellite-based radiative forcing analysis.

Indochina↗

Profiling the SO2 Plume from Volcan Turrialba: Ticosonde Balloon Measurements Compared with OMI and OMPS Retrievals

The summit of Volcan Turrialba (elev. 3340 m) lies less than 50 km upstream in the prevailing easterlies from the Ticosonde balloon launch site at San Jose, Costa Rica, where ECC ozone sondes have been launched regularly since 2005. In 2006 we began to see telltale notches in the ozone profiles in the altitude range between 2 and 6 km. Given the proximity of Turrialba, it seemed likely that SO2 in the volcano's plume was interfering in the chemical reaction in the ECC ozone sonde used to detect ozone. In early 2010, fumarolic activity in the Turrialba crater increased strongly, and the profile notches in our soundings increased in frequency as well, consistent with this hypothesis. In February 2012 we tested a dual ECC sonde system, where an additional sonde is flown on the same payload using a selective SO2 filter. The difference of the measurements in the dual sonde is a direct measure of the amount of SO2 encountered. This first dual sonde passed through the plume, and the data indicated a tropospheric SO2 column of 1.4 DU, comparing favorably with a total column of 1.7 DU in the OMI 3-km linear fit (LF) product at the sonde profile location and at nearly the same time. We are now launching dual sondes on a regular basis with 18 launches in the first 12 months through July 2014; 11 of these have detectable SO2 signals. These soundings have great potential for validation of the Aura OMI and the Suomi-NPP OMPS retrievals of SO2. Here we present the sonde measurements and compare them with two satellite datasets: the Aura OMI Linear Fit (LF) product and the Suomi-NPP OMPS Principal Components Analysis (PCA) boundary layer product. The PCA algorithm reduces retrieval noise and artifacts by more accurately accounting for various interferences in SO2 retrievals such as O3 absorption and rotational Raman scattering. The comparisons with the in situ observations indicate a significant improvement of the PCA algorithm in capturing relatively weak volcanic SO2 signals.

sondes↗

Insights on the dusty torus and neutral torus from optical and X-ray obscuration in a complete volume limited hard X-ray AGN sample

We describe a complete volume limited sample of nearby active galaxies selected by their 14–195 keV luminosity, and outline its rationale for studying the mechanisms regulating gas inflow and outflow. We also describe a complementary sample of inactive galaxies, selected to match the host galaxy properties. The active sample appears to have no bias in terms of active galactic nucleus (AGN) type, the only difference being the neutral absorbing column, which is two orders of magnitude greater for the Seyfert 2s. In the luminosity range spanned by the sample, logL{sub 14−195 keV}[erg s{sup −1}]=42.4–43.7, the optically obscured and X-ray absorbed fractions are 50%–65%. The similarity of these fractions to more distant spectroscopic AGN samples, although over a limited luminosity range, suggests that the torus does not strongly evolve with redshift. Our sample confirms that X-ray unabsorbed Seyfert 2s are rare, comprising not more than a few percent of the Seyfert 2 population. At higher luminosities, the optically obscured fraction decreases (as expected for the increasing dust sublimation radius), but the X-ray absorbed fraction changes little. We argue that the cold X-ray absorption in these Seyfert 1s can be accounted for by neutral gas in clouds that also contribute to the broad-line region (BLR) emission, and suggest that a geometrically thick neutral gas torus co-exists with the BLR and bridges the gap to the dusty torus.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining Cometary Crystal Shapes from IR Spectral Features

A major challenge in deriving the silicate mineralogy of comets is ascertaining how the anisotropic nature of forsterite crystals affects the spectral features' wavelength, relative intensity, and asymmetry. Forsterite features are identified in cometary comae near 10, 11.05-11.2, 16, 19, 23.5, 27.5 and 33 microns [1-10], so accurate models for forsterite's absorption efficiency (Qabs) are a primary requirement to compute IR spectral energy distributions (SEDs, lambdaF lambda vs. lambda) and constrain the silicate mineralogy of comets. Forsterite is an anisotropic crystal, with three crystallographic axes with distinct indices of refraction for the a-, b-, and c-axis. The shape of a forsterite crystal significantly affects its spectral features [13-16]. We need models that account for crystal shape. The IR absorption efficiencies of forsterite are computed using the discrete dipole approximation (DDA) code DDSCAT [11,12]. Starting from a fiducial crystal shape of a cube, we systematically elongate/reduce one of the crystallographic axes. Also, we elongate/reduce one axis while the lengths of the other two axes are slightly asymmetric (0.8:1.2). The most significant grain shape characteristic that affects the crystalline spectral features is the relative lengths of the crystallographic axes. The second significant grain shape characteristic is breaking the symmetry of all three axes [17]. Synthetic spectral energy distributions using seven crystal shape classes [17] are fit to the observed SED of comet C/1995 O1 (Hale-Bopp). The Hale-Bopp crystalline residual better matches equant, b-platelets, c-platelets, and b-columns spectral shape classes, while a-platelets, a-columns and c-columns worsen the spectral fits. Forsterite condensation and partial evaporation experiments demonstrate that environmental temperature and grain shape are connected [18-20]. Thus, grain shape is a potential probe for protoplanetary disk temperatures where the cometary crystalline forsterite formed. The forsterite crystal shapes (equant, b-platelets, c-platelets, b-columns - excluding a- and c-columns) derived from our modeling [17] of comet Hale- Bopp, compared to laboratory synthesis experiments [18], suggests that these crystals are high temperature condensates. By observing and modeling the crystalline features in comet ISON, we may constrain forsterite crystal shape(s) and link to their formation temperature(s) and environment(s).

anisotropic crystal↗

Evaluating a New Homogeneous Total Ozone Climate Data Record from GOME/ERS-2, SCIAMACHY/Envisat, and GOME-2/MetOp-A

The European Space Agency's Ozone Climate Change Initiative (O3-CCI) project aims at producing and validating a number of high-quality ozone data products generated from different satellite sensors. For total ozone, the O3-CCI approach consists of minimizing sources of bias and systematic uncertainties by applying a common retrieval algorithm to all level 1 data sets, in order to enhance the consistency between the level 2 data sets from individual sensors. Here we present the evaluation of the total ozone products from the European sensors Global Ozone Monitoring Experiment (GOME)/ERS-2, SCIAMACHY/Envisat, and GOME-2/MetOp-A produced with the GOME-type Direct FITting (GODFIT) algorithm v3. Measurements from the three sensors span more than 16 years, from 1996 to 2012. In this work, we present the latest O3-CCI total ozone validation results using as reference ground-based measurements from Brewer and Dobson spectrophotometers archived at the World Ozone and UV Data Centre of the World Meteorological Organization as well as from UV-visible differential optical absorption spectroscopy (DOAS)/Système D′Analyse par Observations Zénithales (SAOZ) instruments from the Network for the Detection of Atmospheric Composition Change. In particular, we investigate possible dependencies in these new GODFIT v3 total ozone data sets with respect to latitude, season, solar zenith angle, and different cloud parameters, using the most adequate type of ground-based instrument. We show that these three O3-CCI total ozone data products behave very similarly and are less sensitive to instrumental degradation, mainly as a result of the new reflectance soft-calibration scheme. The mean bias to the ground-based observations is found to be within the 1 plus or minus 1 percent level for all three sensors while the near-zero decadal stability of the total ozone columns (TOCs) provided by the three European instruments falls well within the 1-3 percent requirement of the European Space Agency's Ozone Climate Change Initiative project.

Satellite sensors↗

NASA TROPOMI Aerosol Products: Algorithmic Upgrades and Preliminary Evaluation

This poster presentation describes an expanded NASA TROPOMI (Tropospheric Monitoring Instrument)aerosol algorithm (N-TROPOMAER) that takes advantage of TROPOMI observations in the ultraviolet and visible spectral regions. The availability of the Oxygen B-band observations, and the unprecedentedly high spatial resolution (3.5 km X 5.5 km) for a hyper-spectral sensor are significant improvements for aerosol properties retrieval. The heritage N-TROPOMAER aerosol algorithm uses near-ultraviolet radiances at 354 nm and 388 nm from Sentinel 5 Precursor-TROPOMI for simultaneously retrieving aerosol optical depth (AOD), single-scattering albedo (SSA), aerosol absorption optical depth (AAOD), and above-cloud aerosol optical depth(ACAOD) at 388 nm, along with the qualitative UV aerosol index (UVAI). We have expanded the inversion capability beyond the UV, to retrieve AOD at 466 nm and 680 nm. Surface reflectance effects at466 nm are accounted for using a recently developed geometry-dependent surface Lambertian-equivalent reflectivity (GLER) product, which is derived from the top-of-atmosphere radiance computed with Rayleigh scattering and surface bidirectional reflectance distribution function (BRDF) for the exact viewing geometry at the sensor’s spatial resolution. Aerosol layer height (ALH) and 680 nm AOD are simultaneously derived from observations at 680 nm and at the Oxygen-B band (688 nm). Another important upgrade is the use of time averaged total column carbon monoxide from the NASA GEOS-CF(Global Earth Observing System Composition Forecast) as a tracer of carbonaceous aerosols.

TROPOMI↗

The Coordination Chemistry and Stoichiometry of Extracted Diglycolamide Complexes of Lanthanides in Extraction Chromatography Materials

Industrial rare earth element (REE) separations predominantly utilize solvent extraction processes tailored toward conventional resources such as bastnäsite, monazite, and ion adsorption clays. Advances in diglycolamide (DGA) chemistry have shown effective extraction characteristics for REE separations. However, limitations associated with traditional DGA solvent extraction techniques, such as third-phase formation and gelling, have hindered commercial viability. By supporting DGA extractants on porous resins such as polystyrene divinyl benzene (PS-DVB), the desirable combination of solvent extraction selectivity and ease of operation of sorbent columns can be achieved. To design a low-cost model for such solid-supported DGAs, extraction characteristics as influenced by the underlying coordination chemistry must be explored to achieve efficient functional systems. Within this study, we report novel DGA resin materials, each incorporating one of the DGAs N,N,N’,N’-tetra-(1-octyl)-3-oxapentane-1,5-diamide (TODGA), N,N'-dimethyl-N,N'-dioctyl-3-oxapentane-1,5-diamide (DMDODGA), and 2,2'-oxybis(1-(3-(((2-ethylhexyl)thio)methyl)-4-methylpyrrolidin-1-yl)ethan-1-one) (DEHPDGA). The affinity of DGAs across the lanthanide (Ln) series was evaluated for both hydrochloric acid and nitric acid media with varying Ln feed concentrations to study distribution ratios and loading characteristics. Focusing on dysprosium, extended X-Ray Absorption Fine Structure (EXAFS) and density functional theory (DFT) calculations were also utilized to explore coordination chemistry and their effects on ligand performance. The general trend for both acid media resulted in DMDODGA having the highest extraction strength of all three DGAs at varying acid concentrations. Coordination-chemistry analysis supported by loading data, DFT calculations, and EXAFS results under forced loading conditions posited less than the expected 3:1 ligand-to-metal coordination.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X ray emission from Wolf-Rayet stars with recurrent dust formation

We were granted a ROSAT observation of the Wolf-Rayet star WR 137 (equals HD 192641) to test a proposed mechanism for producing the infrared variability reported by Williams et al. (1987). These studies showed one clear infrared outburst preceded by what may be the dimming of a previous outburst. The recurrent dust formation model was put forward by Williams et al. (1990) to account for similar variability seen in WR 140, which varies in both the infrared and X-ray bands. The detected X-ray flux from WR 140 was observed to decrease from its normally high (for Wolf-Rayet stars) level as the infrared flux increased. Observation of two apparently-periodic infrared outbursts led to the hypothesis that WR 140 had an O star companion in an eccentric orbit, and that the increase in infrared flux came from a dust formation episode triggered by the compression of the O star and Wolf-Rayet star winds. The absorption of the X-rays by the increased material explained the decrease in flux at those wavelengths. If the infrared variability in WR 137 were caused by a similar interaction of the Wolf-Rayet star with a companion, we might expect that WR 137 would show corresponding X-ray variability and an X-ray luminosity somewhat higher than typical WC stars, as well as a phase-dependent non-thermal X-ray spectrum. Our goals in this study were to obtain luminosity estimates from our counting rates for comparison with previous observations of WR 137 and other WC class stars, especially WR 140; to compare the luminosity with the IR lightcurve; and to characterize the spectral shape of the X-ray emission, including the column density.

Rawley, Gayle L.↗

ORION’S VEIL. IV. H{sub 2} EXCITATION AND GEOMETRY

The foreground Veil of material that lies in front of the Orion Nebula is the best studied sample of the interstellar medium because we know where it is located, how it is illuminated, and the balance of thermal and magnetic energy. In this work, we present high-resolution STIS observations toward the Trapezium, with the goal of better understanding the chemistry and geometry of the two primary Veil layers, along with ionized gas along the line of sight. The most complete characterization of the rotational/vibrational column densities of H{sub 2} in the almost purely atomic components of the Veil are presented, including updates to the Cloudy model for H{sub 2} formation on grain surfaces. The observed H{sub 2} is found to correlate almost exclusively with Component B. The observed H{sub 2}, observations of CI, CI*, and CI**, and theoretical calculations using Cloudy allow us to place the tightest constraints yet on the distance, density, temperature, and other physical characteristics for each cloud component. We find the H{sub 2} excitation spectrum observed in the Veil is incompatible with a recent study that argued that the Veil was quite close to the Trapezium. The nature of a layer of ionized gas lying between the Veil and the Trapezium is characterized through the emission and absorption lines it produces, which we find to be the blueshifted component observed in S iii and P iii absorption. We deduce that, within the next 30–60 thousand years, the blueshifted ionized layer and Component B will merge, which will subsequently merge with Component A in the next one million years.

79 ASTRONOMY AND ASTROPHYSICS↗

pwv_kpno: A Python Package for Modeling the Atmospheric Transmission Function Due to Precipitable Water Vapor

In this work, we present a Python package, pwv_kpno, which provides models for the atmospheric transmission due to precipitable water vapor (PWV) at user-specified sites. Using the package, ground-based photometric observations taken between 3000 and 12,000 Å can be corrected for atmospheric effects due to PWV. Atmospheric transmission in the optical and near-infrared is highly dependent on the PWV column density along the line of sight. By measuring the delay of dual-band GPS signals through the atmosphere, the SuomiNet project provides accurate PWV measurements for hundreds of locations around the world. The pwv_kpno package uses published SuomiNet data in conjunction with MODTRAN models to determine the modeled, time-dependent atmospheric transmission. A dual-band GPS system was installed at Kitt Peak National Observatory (KPNO) in the spring of 2015. Using measurements from this receiver we demonstrate that we can successfully predict the PWV at KPNO from nearby dual-band GPS stations on the surrounding desert floor. The pwv_kpno package can thus provide atmospheric transmission functions for observations taken before the KPNO receiver was installed. Using PWV measurements from the desert floor, we correctly model PWV absorption features present in spectra taken at KPNO. Finally, we also demonstrate how to configure the package for use at other observatories.

79 ASTRONOMY AND ASTROPHYSICS↗

Twenty-two emission-line AGNs from the HEAO-1 X-ray survey

We report 22 emission-line AGN as bright, hard X-ray sources. All of them appear to be new classifications with the exception of one peculiar IRAS source which is a known quasar and has no published spectrum. This sample exhibits a rich diversity in optical spectral properties and luminosities, ranging from a powerful broad-absorption-line quasar to a weak nucleus embedded in a nearby NGC galaxy. Two cases confer X-ray luminosities in excess of 10 exp 47 erg/s. However, there is a degree of uncertainty in the X-ray identification for the AGN fainter than V about 16.5. Optically, several AGN exhibit very strong Fe II emission. One Seyfert galaxy with substantial radio flux is an exception to the common association of strong Fe II emission and radio-quiet AGN. The previously recognized IRAS quasar shows extreme velocities in the profiles of the forbidden lines; the 0 III pair is broadened to the point that the lines are blended. Several of these AGN show evidence of intrinsic obscuration, illustrating the effectiveness of hard X-ray surveys in locating AGN through high column density.

Remillard, R. A.↗