Evaluating the Impact of Price-Responsive Load on Power Systems Using Integrated T&D Simulation

This paper explores the differences between simulating price-responsive load (PRL) interactions with power systems using integrated transmission and distribution (T&D) models and transmission-only (T-only) models. This analysis uses the Integrated Grid Modeling System (IGMS) software to capture 'ISO-to-appliance' simulations using a synthetic T&D model built on the PJM 5-Bus transmission network with multiple full-scale taxonomy feeders that include physics-based models of thousands of customers and PRLs. The results show important differences in the impacts of PRLs between integrated T&D and T-only models. Experiments with the synthetic integrated T&D dataset demonstrated that integrated T&D simulation revealed notably larger differences between the PRL and no-PRL cases for load, and prices compared to T-only simulation. Similarly, differences are observed between the price response of individual buildings and distribution feeders and the corresponding transmission bus in the integrated T&D simulations, which are difficult to capture in traditional T-only simulations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization and Optimization of Building Blocks for Specialized Computing Platforms

As noise limits the performance of quantum processors, the ability to characterize this noise and develop methods to overcome it is essential for the future of quantum computing. In this report, we develop a complete set of tools for improving quantum processor performance at the application level, including low-level physical models of quantum gates, a numerically efficient method of producing process matrices that span a wide range of model parameters, and full-channel quantum simulations. We then provide a few examples of how to use these tools to study the effects of noise on quantum circuits.

42 ENGINEERING↗

Final Report: TIP-337 Home Battery System for Cybersecure Energy Efficiency and Demand Response

Many challenges related to energy use and grid participation face the residential building sector and utilities that serve our homes today. To reduce energy consumption, increase grid service participation, and improve homeowner benefits, a solution is needed that can adapt itself to each home and homeowner/occupant, that can deliver both building and grid services with reliability and high availability, that can automate these operations to minimize cost and complexity of deployment, and that can provide both home data privacy and grid cybersecurity. We hypothesize that customer-oriented home automation can mutually satisfy home occupant/owner needs, reduce energy consumption, and deliver reliable grid services. This project seeks to develop innovative technology solutions that prove this hypothesis. The Home Battery System (HBS) is a technology package comprised of connected 'smart' appliances, rooftop solar photovoltaics, a home battery, and a coordinating smart controller. This system is envisioned, developed and demonstrated by the National Renewable Energy Laboratory (NREL), Bosch, ESCRYPT and Colorado State University (CSU). It is the result of three years of research by our diverse team. NREL developed the home automation controller, and performed simulation and laboratory evaluations of the HBS. Bosch developed and delivered most of the connected appliances used in the project, and provided technical and commercialization guidance. ESCRYPT led cybersecurity analysis and developed the cybersecurity layer. CSU provided leadership on preference elicitation methodologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling Slag Penetration and Refractory Degradation Using the Finite Element Method

Refractory degradation due to slag penetration can significantly reduce the service life of gasifier refractory linings. This paper describes a modeling approach that was developed to predict refractory spalling as a function of operating temperature, coal feedstock and refractory type. The model simulates the coupled thermal, diffusion, and mechanical interactions of coal slag with refractory ceramics. The heat transfer and slag diffusion solutions are directly coupled through a temperature-dependent effective diffusivity for slag penetration. The effective diffusivity is defined from slag penetration tests conducted in our laboratories on specific coal slag and refractory combinations. Chemically-induced swelling of the refractory and the build-up of mechanical stresses are functions of the slag penetration. The model results are compared with analytical spalling models and validated by experimental data in order to develop an efficient refractory degradation model for implementation in a systems level gasifier model. The ultimate goal of our research is to provide a tool that will help optimize gasifier performance by balancing conversion efficiency with refractory life.

01 COAL, LIGNITE, AND PEAT↗

Seasonal performance evaluation of zero-superheat active refrigerant charge control for variable-speed heat pumps

Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.

Guo, Fangzhou↗

Building fault detection data to aid diagnostic algorithm creation and performance testing

It is estimated that approximately 4-5% of national energy consumption can be saved through corrections to existing commercial building controls infrastructure and resulting improvements to efficiency. Correspondingly, automated fault detection and diagnostics (FDD) algorithms are designed to identify the presence of operational faults and their root causes. A diversity of techniques is used for FDD spanning physical models, black box, and rule-based approaches. A persistent challenge has been the lack of common datasets and test methods to benchmark their performance accuracy. This article presents a first of its kind public dataset with ground-truth data on the presence and absence of building faults. This dataset spans a range of seasons and operational conditions and encompasses multiple building system types. It contains information on fault severity, as well as data points reflective of the measurements in building control systems that FDD algorithms typically have access to. The data were created using simulation models as well as experimental test facilities, and will be expanded over time.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Status Report on the Component Models Developed in the Modelica Framework: Reverse Osmosis Desalination Plant & Thermal Energy Storage

This report has been prepared as part of an effort to design and build a Modeling and Simulation (M&S) framework to assess the economic viability of a Nuclear-Renewable Hybrid Energy System (N-R HES). In order to facilitate dynamic M&S of such an integrated system, research groups in multiple national laboratories and universities have been developing various subsystems as dynamic physics-based components using the Modelica programming language. In Fiscal Years (FYs) 2015, Idaho National Laboratory (INL) performed a dynamic analysis of two region-specific N-R HES configurations, including the gas-to-liquid (natural gas to Fischer-Tropsch synthetic fuel) and brackish water Reverse Osmosis (RO) desalination plants as industrial processes. In FYs 2016–2017, INL developed two additional subsystems in the Modelica framework: (1) a high-temperature steam electrolysis plant as a high priority industrial plant to be integrated with a light water reactor within an N-R HES and (2) a gas turbine power plant as a secondary energy supply. In FY 2018, the RO desalination system model developed in FY 2015 has been updated such that the model is compatible with the most recent version of the ThermoPower library. Special attention has been given to the controller settings based on process models, aiming to improve process dynamics and controllability. A dynamic performance analysis of the updated RO desalination plant was carried out to evaluate the technical feasibility (load-following capability) of such a system operating under highly variable conditions requiring flexible output. Simulation results involving several case studies show that the suggested control scheme could maintain the controlled variables (including the variable electrical load and RO feed pressure) within desired limits under various plant operating conditions. The results also indicate that the proposed RO plant could provide operational flexibility to participate in energy management at the utility scale by dynamically optimizing the use of excess plant capacity within an N-R HES. For a small-scale energy storage system, a sensible Thermal Energy Storage (TES) model has been developed in the Modelica Framework in FY 2018.

25 ENERGY STORAGE↗

Empirical Validation of Multi-Zone HVAC System Model: Evaluation of Existing Infiltration Models used in Building Energy Simulation

Infiltration can have a significant impact on building loads. Studies have shown that infiltration can account for 15-40% of annual space conditioning needs in commercial buildings (Emmerich et al. 2019; Younes et al. 2012). The driving force of infiltration is the pressure difference across the building envelope caused by wind, the stack effect (known as buoyancy effect), and the operation of ventilation equipment. Wind pressure is governed by wind direction, speed, building shape, and other structures around the building. The stack effect is a function of the building height and air density differences of ambient air (Han, 2015). The effect of wind is dominant in low-rise residential buildings, and the stack effect is dominant in highrise buildings (ASHRAE 2017). In building energy simulation programs (e.g., EnergyPlus), various empirical infiltration models (e.g., the effective leakage area model, the flow coefficient model) are available to simulate infiltration rates. To help users in selecting a proper infiltration model for modeling of the two-story Flexible Research Platform (FRP), the team evaluates the existing infiltration models in EnergyPlus based on field measurements from the FRP. The blower door and tracer gas decay tests were performed in the FRP. The blower door test result was used to estimate input parameters required in the infiltration models. The actual infiltration rates were estimated with the tracer gas decay test results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulating Operations at a Spaceport

SPACESIM is a computer program for detailed simulation of operations at a spaceport. SPACESIM is being developed to greatly improve existing spaceports and to aid in designing, building, and operating future spaceports, given that there is a worldwide trend in spaceport operations from very expensive, research- oriented launches to more frequent commercial launches. From an operational perspective, future spaceports are expected to resemble current airports and seaports, for which it is necessary to resolve issues of safety, security, efficient movement of machinery and people, cost effectiveness, timeliness, and maximizing effectiveness in utilization of resources. Simulations can be performed, for example, to (1) simultaneously analyze launches of reusable and expendable rockets and identify bottlenecks arising from competition for limited resources or (2) perform what-if scenario analyses to identify optimal scenarios prior to making large capital investments. SPACESIM includes an object-oriented discrete-event-simulation engine. (Discrete- event simulation has been used to assess processes at modern seaports.) The simulation engine is built upon the Java programming language for maximum portability. Extensible Markup Language (XML) is used for storage of data to enable industry-standard interchange of data with other software. A graphical user interface facilitates creation of scenarios and analysis of data.

Nevins, Michael R.↗

Modern Design of Resonant Edge-Slot Array Antennas

Resonant edge-slot (slotted-waveguide) array antennas can now be designed very accurately following a modern computational approach like that followed for some other microwave components. This modern approach makes it possible to design superior antennas at lower cost than was previously possible. Heretofore, the physical and engineering knowledge of resonant edge-slot array antennas had remained immature since they were introduced during World War II. This is because despite their mechanical simplicity, high reliability, and potential for operation with high efficiency, the electromagnetic behavior of resonant edge-slot antennas is very complex. Because engineering design formulas and curves for such antennas are not available in the open literature, designers have been forced to implement iterative processes of fabricating and testing multiple prototypes to derive design databases, each unique for a specific combination of operating frequency and set of waveguide tube dimensions. The expensive, time-consuming nature of these processes has inhibited the use of resonant edge-slot antennas. The present modern approach reduces costs by making it unnecessary to build and test multiple prototypes. As an additional benefit, this approach affords a capability to design an array of slots having different dimensions to taper the antenna illumination to reduce the amplitudes of unwanted side lobes. The heart of the modern approach is the use of the latest commercially available microwave-design software, which implements finite-element models of electromagnetic fields in and around waveguides, antenna elements, and similar components. Instead of building and testing prototypes, one builds a database and constructs design curves from the results of computational simulations for sets of design parameters. The figure shows a resonant edge-slot antenna designed following this approach. Intended for use as part of a radiometer operating at a frequency of 10.7 GHz, this antenna was fabricated from dimensions defined exclusively by results of computational simulations. The final design was found to be well optimized and to yield performance exceeding that initially required.

Gosselin, R. B.↗

26th Space Simulation Conference Proceedings. Environmental Testing: The Path Forward

Topics covered include: A Multifunctional Space Environment Simulation Facility for Accelerated Spacecraft Materials Testing; Exposure of Spacecraft Surface Coatings in a Simulated GEO Radiation Environment; Gravity-Offloading System for Large-Displacement Ground Testing of Spacecraft Mechanisms; Microscopic Shutters Controlled by cRIO in Sounding Rocket; Application of a Physics-Based Stabilization Criterion to Flight System Thermal Testing; Upgrade of a Thermal Vacuum Chamber for 20 Kelvin Operations; A New Approach to Improve the Uniformity of Solar Simulator; A Perfect Space Simulation Storm; A Planetary Environmental Simulator/Test Facility; Collimation Mirror Segment Refurbishment inside ESA s Large Space; Space Simulation of the CBERS 3 and 4 Satellite Thermal Model in the New Brazilian 6x8m Thermal Vacuum Chamber; The Certification of Environmental Chambers for Testing Flight Hardware; Space Systems Environmental Test Facility Database (SSETFD), Website Development Status; Wallops Flight Facility: Current and Future Test Capabilities for Suborbital and Orbital Projects; Force Limited Vibration Testing of JWST NIRSpec Instrument Using Strain Gages; Investigation of Acoustic Field Uniformity in Direct Field Acoustic Testing; Recent Developments in Direct Field Acoustic Testing; Assembly, Integration and Test Centre in Malaysia: Integration between Building Construction Works and Equipment Installation; Complex Ground Support Equipment for Satellite Thermal Vacuum Test; Effect of Charging Electron Exposure on 1064nm Transmission through Bare Sapphire Optics and SiO2 over HfO2 AR-Coated Sapphire Optics; Environmental Testing Activities and Capabilities for Turkish Space Industry; Integrated Circuit Reliability Simulation in Space Environments; Micrometeoroid Impacts and Optical Scatter in Space Environment; Overcoming Unintended Consequences of Ambient Pressure Thermal Cycling Environmental Tests; Performance and Functionality Improvements to Next Generation Thermal Vacuum Control System; Robotic Lunar Lander Development Project: Three-Dimensional Dynamic Stability Testing and Analysis; Thermal Physical Properties of Thermal Coatings for Spacecraft in Wide Range of Environmental Conditions: Experimental and Theoretical Study; Molecular Contamination Generated in Thermal Vacuum Chambers; Preventing Cross Contamination of Hardware in Thermal Vacuum Chambers; Towards Validation of Particulate Transport Code; Updated Trends in Materials' Outgassing Technology; Electrical Power and Data Acquisition Setup for the CBER 3 and 4 Satellite TBT; Method of Obtaining High Resolution Intrinsic Wire Boom Damping Parameters for Multi-Body Dynamics Simulations; and Thermal Vacuum Testing with Scalable Software Developed In-House.

Packard, Edward A.↗

Aerospace Cognitive Engineering Laboratory (ACELAB) Simulator for Electric Vertical Takeoff and Landing (eVOTL) Research and Development

A new generation of aerospace innovators are looking for ways to quickly and efficiently transport people in a safe and environmentally friendly manner. In the not-too-distant future, passengers and goods are expected to routinely fly aboard a new breed of cleaner, smarter air vehicles. This represents a new and significant challenge to the Federal Aviation Agency (FAA) which is responsible for aircraft certification, pilot licensing, operating approval and airspace integration. To help streamline this process, NASA has formulated its Advanced Air Mobility (AAM) project to provide research capabilities for development and evaluation of these new concepts and an environment where industry and regulators can work together to understand the requirements and work toward consensus standards for the new market. This paper will describe the development of the Aerospace Cognitive Engineering Lab Rapid Automation Test (ACELeRATE) simulator. ACELeRATE is an adaptable fixed-base aircraft simulator focused on the investigation of the performance and interaction of pilots and increasingly automated aircraft systems. ACELeRATE can be re-configured to support various simulation environments. The simulator includes a simple reconfigurable cockpit placed within a 10-foot spherical dome with a cluster of real-time image generators, high-resolution displays and highly realistic scenery with the surrounding digital terrain and required cultural area details (e.g., hangars, runways, ramp areas, taxiways, test range apparatus, buildings with designated rooftop landing areas, and other man-made 3D structures). This paper will also describe the various hardware and software tools employed in the ACELeRATE simulator, including engineering tools used by NASA for electric Vertical Takeoff and Landing (eVTOL) vehicle equations of motion, wind-model simulation in an urban environment, as well as the various modeling techniques and tools used to quickly generate highly realistic 3D terrain models for low level flight including urban terrain and obstacle depictions.

AAM Simulation Cockpit↗

Characterizing Fit Factor of a One Size Fits-Most Emergency Mask using Subjects with Smaller Neck Circumferences

The Emergency Mask (EM) is an integral part of fire response on ISS, Orion and Gateway. The EM is a hood type protection respirator sealing around the subject’s neck, with an additional nose cup covering the subject’s oral nasal region. When integrated with a pair of Fire Cartridges (FCs), this system can be used to provide safe breathing air in a post-fire environment. The initial EM was certified as a ‘one size fits most’, however a recent requirements scrub discovered that the neck circumferences of the smallest possible crew population were not included in the initial requirement set. The test described in this paper uses the same slightly modified industry standard respirator test called a ‘Fit Factor’ used to certify the existing EM for larger subjects. Tests were performed on eight test subjects with neck circumference smaller than the initial EM requirement to determine if the current EM provided adequate protection during post-fire scenarios. The test included subjects donning an EM and then performing a number of head movements in a tent filled with approximately 50,000 particles/cm3 of smoke particulate. During these motions, particulate measurements were obtained from within the EM and compared with particulate measurements in the surrounding environment to determine the protection the EM provided in a simulated post-fire environment. This paper provides descriptions of the test hardware, methodology and results, which have provided rationale to design and build an EM to accommodate subjects with smaller necks.

Respirator↗

The Dark Energy Survey Camera (DECam)

The Dark Energy Survey (DES) is a next generation optical survey aimed at understanding the expansion rate of the Universe using four complementary methods: weak gravitational lensing, galaxy cluster counts, baryon acoustic oscillations, and Type Ia supernovae. To perform the survey, the DES Collaboration is building the Dark Energy Camera (DECam), a 3 square degree, 570 Megapixel CCD camera that will be mounted at the prime focus of the Blanco 4-meter telescope at the Cerro Tololo Inter-American Observatory. CCD production has finished, yielding roughly twice the required 62 2k x 4k detectors. The construction of DECam is nearly finished. Integration and commissioning on a 'telescope simulator' of the major hardware and software components, except for the optics, recently concluded at Fermilab. Final assembly of the optical corrector has started at University College, London. Some components have already been received at CTIO. 'First-light' will be sometime in 2012. This oral presentation concentrates on the technical challenges involved in building DECam (and how we overcame them), and the present status of the instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Taking a fresh look at boiling heat transfer on the road to improved nuclear economics and efficiency

Here, in the effort to reinvigorate innovation in the way we design, build, and operate the nuclear power generating stations of today and tomorrow, nothing can be taken for granted. Not even the seemingly familiar physics of boiling water. The Consortium for the Advanced Simulation of Light Water Reactors, or CASL, is focused on the deployment of advanced modeling and simulation capabilities to enable the nuclear industry to reduce uncertainties in the prediction of multi-physics phenomena and continue to improve the performance of today’s Light Water Reactors and their fuel. An important part of the CASL mission is the development of a next generation thermal hydraulics simulation capability, integrating the history of engineering models based on experimental experience with the computing technology of the future.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

How to Safely Build 100-plus Kilograms of Weapons-Grade Plutonium

The goal of the EUCLID (Experiments Underpinned by Computational Learning for Improvements in Nuclear Data) project was to reduce compensating errors by utilizing machine learning to both help determine which reactions contain compensating errors as well as optimizing an experiment which can be used to maximally reduce these errors. Compensating errors can adversely impact the predictive power of application simulations, and therefore it’s useful to further constrain nuclear data and reduce these errors. The EUCLID project included building two configurations at the National Criticality Experiments Research Center (NCERC). These two configurations had very different geometries (one was cube-like and one was slab-like). Previous works focus on selection of the target experiment(s), radiation transport capabilities developed in the project, the experiment optimization, and the performance of the experiments. This work will focus only on the safety aspects of performing this experiment, which utilized over 100 kg of weapons-grade plutonium.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Minimizing User Burden in Building Energy Analysis

Infrared (IR) imagery can provide valuable data to building energy auditors and the developers of Building Energy Models (BEM). IR by itself is not a panacea to the challenges facing energy auditors and modelers, but when combined with other techniques and Open Studio software, IR can play an important role in the minimization of the burden of creating building energy models and the diagnosing of building energy problems. While IR can be used to detect and quantify many aspects of a building’s thermal and energy performance, in Phase I we focused on a single capability: determining the R value of exterior walls. Two key attributes of using IR methods for R value determination is that IR methods measure the actual, installed performance in-situ – as opposed to relying on manufacturer or handbook values – and they can integrate performance over a wide area and thus can accurately account for thermal bridging and spatial anomalies such as “spotty” insulation installation. There is a trade between user burden and accuracy when using IR to determine a wall’s R value. The least burdensome approach is computing R values from a single IR snapshot. The most burdensome method we considered was to combine IR images with thermocouple and heat flux sensor (HFS) measurements made over the course of several days. The more effort users expend in making the measurements, the more accurate and robust the method becomes. Through a series of field tests at the ThermoAnalytics Inc. (TAI) HQ at Calumet, MI and a simulation of a 1980s era office building in Flagstaff, AZ we investigated methods to compute the R value of exterior walls using data from IR cameras, thermocouples and heat flux sensors. To compute R values the heat flux through the wall, along with temperatures on either side of the wall, must be known, modeled, or estimated – and the temperature difference through the wall should be at least 10 C. If only outdoor IR images are used in the method, the inside ambient air temperature must be estimated, and a simulation model created to predict heat fluxes and the indoor wall temperature. The accuracy of the resulting R value depends on the accuracy of the simulation and the assumptions it employs. Applying thermocouple sensors, either as iButtons or as part of a wireless sensor network, to the walls allows for the acquisition of temperatures over time. The longer the duration of the measurements, the more accurate and robust the method will be. Even with this level of measurement effort, modeling is still required to calculate the heat flux through the wall. The addition of a heat flux sensor alleviates the need for any modeling, and that results in improved accuracy. Driving the accuracy of the methods are several factors that can be quantified. How well are the wall surface temperatures known? Modeling the heat flux through walls requires knowing the details of the surrounding radiant environment and the heat transfer due to convection. How well are these boundary conditions known? Even when the heat flux is measured, error can arise when some of the measured heat is not conducted through the wall but rather goes into the thermal mass of the wall. Thermal mass effects occur when conditions and the heat flux values are fluctuating. A technique that is not robust will suffer in accuracy when these fluctuations occur. The R value determination method must be incorporated into the Open Studio process. In our proposed process, IR images and other measured sensor data are input into a module that would send R value estimates to a building library developed by team member Skidmore, Owings, & Merrill (SOM). This library of parameterized building models would use these R values along with information about the building’s age, type, and location to query the Open Studio BCL to identify the most likely constructions for walls, roof, and windows. Being based on the IMF feature of Energyplus, the SOM building library can quickly produce Energyplus models of buildings based on a limited number of user inputs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the Performance, Application, and Cost of Retrofit Wall Systems for Residential Buildings

The Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and the University of Minnesota have been conducting a three-year study of residential retrofit wall systems. The researchers have identified, tested, and verified the hygrothermal performance of 16 wall assemblies in retrofit applications. The approach to this study includes a comprehensive literature review, the involvement of an advisory group of thermal enclosure experts, smallscale experimental in situ testing of the wall assemblies at the University of Minnesota’s Cloquet Residential Research Facility, and energy and hygrothermal simulation of wall assemblies using EnergyPlus, THERM, and WUFI. Simulation and experimental results are then combined with an economic analysis to produce a techno-economic study of residential wall systems for deep energy retrofits.This presentation summarizes the findings of this research project and is intended to guide architects and designers on how to retrofit existing wall assemblies without creating durability issues.

Desjarlais, Andre Omer↗