Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Development of ion specific media to treat Sr-contaminated water at Fukushima Daiichi Nuclear Power Plant - 15486

Since April of 2011, Kurion, Inc. contracted with the Tokyo Electric Power Company (TEPCO) to remediate cooling water using Ion Specific Media targeting cesium (Cs). The effluent of the Cs-sorption systems routed into a reverse osmosis (RO) system. While the RO permeate was recirculated into the cooling loop, the RO reject was captured in carbon-steel tanks. However, the cesium-extracted tank water at Fukushima Daiichi also has a high strontium (Sr) activity (∼4 x 10{sup 5} Bq/mL) and needs to be reduced to lower the onsite and boundary doses. To treat this highly contaminated water, Kurion developed the Kurion Mobile Processing System (KMPS). The KMPS uses a powder batch-contact addition step in concert with a series of ion exchange vessels to decontaminate the high Sr-activity water. Kurion tested and developed several ion specific media to treat the water. Several inorganic media were evaluated in the down-select for the system. Equilibrium batch tests, shortened contact time batch tests and column tests were performed to assess the media depending on water conditions. Two media were selected for KMPS: FAS-P (a powdered zeolite) to reduce Ca{sup 2+} and Sr{sup 2+} concentrations and TS-G (a synthetic titanosilicate) to polish the Sr{sup 2+} downstream. The results of these laboratory tests and their performance in the field will be discussed. The operation of the system has led to the continued reduction of dose at the Fukushima Daiichi nuclear power plant. This system and these media can be applied to other difficult wastewater solutions involving high levels of contaminants and salinity. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High Angle Remediation of Legacy Mercury Contaminated Soil at LANL - 16276

Mercury contaminated soil was left behind by The Manhattan Project and early Cold War era operations at Los Alamos National Laboratory (LANL) in Los Alamos, NM. TerranearPMC (TPMC) was the subcontractor that successfully completed this high-angle, legacy cleanup project on a steep, difficult-to-access canyon wall in Upper Los Alamos Canyon Aggregate Area south of a busy shopping center parking lot. A Menzi Muck (spider excavator) was used in concert with a high capacity telescoping crane to remove approximately 158 cubic yards of contaminated rock and soil from the steep slope. The crane was also used to safely move personnel and equipment into and off of the site, as well as to retrieve packaged waste. All soil excavated from the site was containerised in soft-sided 1.77 cubic yard IP-1 containers and shipped to an approved, licensed, off-site disposal facility. Once excavation was completed, sampling confirmed that human health concerns and environmental risk issues had been mitigated. This proven technical approach will become the preferred method for cleaning up other similar, difficult-to access/steep legacy waste sites across the Upper Los Alamos Canyon Aggregate Area. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extremely Highly Volume Reduction of r-Cs Contaminated Wastes by Using Ion Exchanging Chromatography - 18248

Calcination or melting processes remove radio-Cs from contaminated soil and incineration ashes when appropriate amounts of CaO and CaCl{sub 2} are added. The byproducts from the heat treatment system are concentrated water-soluble alkali chlorides, mainly composed of KCl with small amounts of CsCl contaminated with radio-Cs. These methods may effectively reduce the volume of wastes to as much as 1/100. the initial volume in the best condition. Further volume reduction from the concentrated salts is investigated by using ion-exchange chromatography of transitional metal ferrocyanides. Copper ferrocyanide (CuFeCN) is chosen as the optimum salt as it has a high ion selectivity coefficient of 2.75 x 10{sup 4} and ion-exchange capacity of 0.29 mmol/g. This CuFeCN is supported by porous silica gel carrier and is used in the ion-exchange column. A solution containing 1.34 M of KCl and 1.34 mM of CsCl labelled with Cs-137 is flowed through the column. A maximum of 80% absorbing capacity of CuFeCN and 99.9% removal efficiency of radio-Cs are achieved. Because the used adsorbent contains a high concentration of radio-Cs, it must be solidified and scattering or leaching out must be prevented. Therefore, 10 g of the used adsorbent is mixed with 20 g of meta-kaolin, 7 g of NaOH, and 18 g of water and the 'geopolymer' mixture is solidified under room temperature. No ratio-Cs release is detected from this solidified material when it is immersed in sea water or pure water for a month at 40 deg. C. Using the proposed method, the final volume of the waste could be reduced to approximately 1/10,000. the initial volume. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Development of Legacy Waste Scaling Factors for Radioactively Contaminated Soils at Chalk River Laboratories - 19333

The Chalk River Laboratories (CRL) began nuclear operations in 1947. Beginning in 1952 after the NRX accident, the management of excess contaminated liquids from the accident, and later in 1953, other waste liquids, were intermittently dispersed to trenches and pits in the local sand. The local sands proved effective at immobilization of actinides, and most activation and fission products. However there was very limited retention of some more commonly mobile radionuclides. Sand filtration performance and radionuclide migration was studied beginning in 1952. Monitoring data indicated slow migration of most radioactive contaminants away from the trenches and pits due to the adsorbing capacity of the sand substrate. The radionuclide migration continues to be studied today in frequent plume monitoring studies. Because many hard-to measure (HTM) radionuclides may also present as long term dose contributors in post remediation scenarios, or in disposal site performance assessments, the quantification of these HTM radionuclides is important. The use of scaling factors between HTM radionuclides and easy-to-measure (ETM) radionuclides (gamma emitters) for packaged soil wastes would alleviate significant effort in sampling individual waste containers. As part of plume monitoring studies and the environmental remediation process, significant characterization of soils have been performed at the site. The soil sample data from multiple historic waste management areas across site is combined and relationships between HTM radionuclides and ETM or key radionuclides are examined. Additional (secondary) relationships between ETM key nuclides are also explored to evaluate secondary scaling relationships between ETM key radionuclides (e.g., Co- 60/Cs-137), because of the significant decay of the activation product key radionuclide Co-60, (predominantly 10-20 half-lives). The evaluation is yielding consistent scaling factors for legacy soil wastes in the historic waste management areas. Given the hydrogeology of the site, a sandy shallow unconfined aquifer, and the annual precipitation of about 0.85 m/a, this evaluation reveals some expected relationships between fission products and actinides and some unanticipated relationships between more mobile radionuclides and key gamma emitters. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Geochemical Reactions Controlling Contaminant Transport in Groundwater at a Former Uranium Mill Site - 19576

The historical operation of a uranium mill near Tuba City, Arizona, contaminated the underlying groundwater. Initial characterization led to a compliance strategy using groundwater extraction and treatment, which operated from 2002 through 2014. Remediation progress was inhibited primarily by aquifer productivity. Geochemical testing was undertaken to better understand future potential for contaminant plume migration. Results indicated the presence of solid-phase uranium in the subsurface, which can continue to feed the groundwater plume, along with limited uranium sorption on uncontaminated material. Future transport modeling will incorporate the laboratory-quantified geochemical reactions and be used to evaluate site compliance strategies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced Monte Carlo Simulation of the Voxel Phantom Lattice Submersed in a Contaminated Air Environment

External dose coefficient calculations reported for submersions in semi-infinite clouds, as in the Environmental Protection Agency: Federal Guidance Report 12, assume a person standing on the ground submerged in a radioactive cloud. In the scope of the work presented here, Oak Ridge National Laboratory's Center for Radiation Protection Knowledge has computed dose coefficients for monoenergetic photons, electrons, and positrons for worker exposures in three rooms of finite sizes representing an office, laboratory, and warehouse. In the process of simulating these exposures, International Commission on Radiological Protection (ICRP) Publication 110 reference adult male and female voxel phantom lattices were placed in the rooms filled with contaminated air. It was apparent that additional simulations were need to treat the non-tissue voxels surrounding the phantoms as containing the contaminated air. Dose coefficients for three room sizes representing an office, laboratory, and warehouse were computed. The coefficients for electrons exhibit little dependence on room size for most energies. However, for organs within the range of electron transport, the dose from source activity within the non-tissue voxels of the lattice surrounding the phantom becomes increasingly important. The photon dose coefficients vary based on room size because of longer mean free paths. It is important to include the air surrounding the voxel phantom within the voxel lattice in the calculations, when simulating a voxel phantom submersed in air for source particle energies below 200-300 keV, otherwise, the organ dose coefficient would be underestimated. Organ and effective dose coefficients for each gender, energy, and room size will be tabulated on the Oak Ridge National Laboratory - Center for Radiation Protection Knowledge website: http://ornl.gov/crpk.

61 RADIATION PROTECTION AND DOSIMETRY↗

Method for removing contaminants from plastic resin

A method for removing contaminants from synthetic resin material containers using a first organic solvent system and a second carbon dioxide system. The organic solvent is utilized for removing the contaminants from the synthetic resin material and the carbon dioxide is used to separate any residual organic solvent from the synthetic resin material.

Bohnert, George W↗

Electrodic voltages accompanying stimulated bioremediation of a uranium-contaminated aquifer

The inability to track the products of subsurface microbial activity during stimulated bioremediation has limited its implementation. We used spatiotemporal changes in electrodic potentials (EP) to track the onset and persistence of stimulated sulfate-reducing bacteria in a uranium-contaminated aquifer undergoing acetate amendment. Following acetate injection, anomalous voltages approaching -900 mV were measured between copper electrodes within the aquifer sediments and a single reference electrode at the ground surface. Onset of EP anomalies correlated in time with both the accumulation of dissolved sulfide and the removal of uranium from groundwater. The anomalies persisted for 45 days after halting acetate injection. Current-voltage and current-power relationships between measurement and reference electrodes exhibited a galvanic response, with a maximum power density of 10 mW/m{sup 2} during sulfate reduction. We infer that the EP anomalies resulted from electrochemical differences between geochemically reduced regions and areas having higher oxidation potential. Following the period of sulfate reduction, EP values ranged from -500 to -600 mV and were associated with elevated concentrations of ferrous iron. Within 10 days of the voltage decrease, uranium concentrations rebounded from 0.2 to 0.8 {mu}M, a level still below the background value of 1.5 {mu}M. These findings demonstrate that EP measurements provide an inexpensive and minimally invasive means for monitoring the products of stimulated microbial activity within aquifer sediments and are capable of verifying maintenance of redox conditions favorable for the stability of bioreduced contaminants, such as uranium.

54 ENVIRONMENTAL SCIENCES↗

Feed gas contaminant removal in ion transport membrane systems

Method for gas purification comprising (a) obtaining a feed gas stream containing one or more contaminants selected from the group consisting of volatile metal oxy-hydroxides, volatile metal oxides, and volatile silicon hydroxide; (b) contacting the feed gas stream with a reactive solid material in a guard bed and reacting at least a portion of the contaminants with the reactive solid material to form a solid reaction product in the guard bed; and (c) withdrawing from the guard bed a purified gas stream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method for removing contaminants from plastic resin

A resin recycling method that produces essentially contaminant-free synthetic resin material in an environmentally safe and economical manner. The method includes receiving the resin in container form. The containers are then ground into resin particles. The particles are exposed to a solvent, the solvent contacting the resin particles and substantially removing contaminants on the resin particles. After separating the particles and the resin, a solvent removing agent is used to remove any residual solvent remaining on the resin particles after separation.

36 MATERIALS SCIENCE↗

Method of removing contaminants from plastic resins

A method for removing contaminants from synthetic resin material containers using a first organic solvent system and a second carbon dioxide system. The organic solvent is utilized for removing the contaminants from the synthetic resin material and the carbon dioxide is used to separate any residual organic solvent from the synthetic resin material.

42 ENGINEERING↗

Monolayer organic thin films as particle-contamination–resistant coatings

Abstract Three organic monolayers coatings were developed and tested for their effectiveness to increase cleaning efficiency of attached microscale particles by air flows. The experiments were performed using silica substrates coated with these organic thin films and subsequently exposed to stainless-steel and silica microparticles as a model of contamination. Laser-induced–damage tests confirmed that the coatings do not affect the laser-induced–damage threshold values. The particle exposure results suggest that although the accumulation of particles is not significantly affected under the experimental conditions used in this work, the coated substrates exhibit significantly improved cleaning efficiency with a gas flow. A size-distribution analysis was conducted to study the adsorption and cleaning efficiency of particles of different sizes. It was observed that larger size (> 5-μm) particles can be removed from coated substrates with almost 100% efficiency. It was also determined that the coatings improve the cleaning efficiency of the smaller particles (≤ 5 μm) by 17% to 30% for the stainless steel metal and 19% to 38% for the silica particles.

36 MATERIALS SCIENCE↗

Determinants of the use of alternatives to arsenic-contaminated shallow groundwater: an exploratory study in rural West Bengal, India

Shallow groundwater containing toxic concentrations of arsenic is the primary source of drinking water for millions of households in rural West Bengal, India. Often, this water also contains unpleasant levels of iron and non-negligible fecal contamination. Alternatives to shallow groundwater are increasingly available, including government-built deep tubewells, water purchased from independent providers, municipal piped water, and household filters. We conducted a survey of 501 households in Murshidabad district in 2014 to explore what influenced the use of available alternatives. Socioeconomic status and the perceived likelihood of gastrointestinal (GI) illness (which was associated with dissatisfaction with iron in groundwater) were the primary determinants of the use of alternatives. Arsenic knowledge was limited. The choice amongst alternatives was influenced by economic, social, and aesthetic factors, but not by health risk perceptions. The use of purchased water was rarely exclusive and was strongly associated with socioeconomic status, suggesting that this form of market-based water provision does not ensure universal access. Demand for purchased water appeared to decrease significantly shortly after free piped water became available at public taps. Finally, our results suggest that arsenic mitigation interventions that also address co-occurring water problems (iron, GI illness) could be more effective than a focus on arsenic alone.

54 ENVIRONMENTAL SCIENCES↗

Contamination Impact of Station Brush Fire on Cleanroom Facilities

Brush and forest fires, both naturally occurring and anthropogenic in origin, in proximity to space flight hardware processing facilities raise concerns about the threat of contamination resulting from airborne particulate and molecular components of smoke. Perceptions of the severity of the threat are possibly heightened by the high sensitivity of the human sense of smell to some components present in the smoke of burning vegetation.On August 26th, 2009, a brushfire broke out north of Pasadena, California, two miles from the Jet Propulsion Laboratory. The Station Fire destroyed over 160,000 acres, coming within a few hundred yards of JPL. Smoke concentrations on Lab were very heavy over several days. All Lab operations were halted, and measures were taken to protect personnel, critical hardware, and facilities. Evaluation of real-time cleanroom monitoring data, visualinspection of facilities, filter systems, and analysis of surface cleanliness samples revealed facility environments andhardware were minimally effected.Outside air quality easily exceeded Class Ten Million. Prefilters captured most large ash and soot; multi-stage filtration greatly minimized the impact on the HEPA/ULPA filters. Air quality in HEPA filtered spacecraft assembly cleanrooms remained within Class 10,000 specification throughout. Surface cleanliness was inimally affected, as large particles were effectively removed from the airstream, and sub-micron particles have extremely long settling rates. Approximate particulate fallout within facilities was 0.00011% area coverage/day compared to 0.00038% area coverage/day during normal operations. Deposition of condensable airborne components, as measured in real time, peaked at approximately1.0 ng/cm2/day compared to 0.05 ng/cm2/day nominal.

airborne particulate contamination↗

Performance of Flight Compatible Microlith® Catalytic Oxidizer for Exploration Trace Contaminant Control

Precision Combustion, Inc. (PCI) and NASA Marshall Space Flight Center have been developing, characterizing, and optimizing prototype high temperature catalytic oxidizers based on PCI’s patented Microlith® technology and long-term endurance test data to meet the requirements of future spaceflight exploration missions. Based on the demonstrated performance (20,000+ hours) of a subscale prototype, a next-generation prototype was designed to meet exploration contaminant load control demands while upgrading the prototype form and fit to match flight-compatible interfaces. Prototype design considerations intended to minimize power consumption, impacting process thermal and hydraulic performance, are discussed herein. We also report on performance characteristics of the catalytic oxidizer and future efforts for component packaging and light-weighting.

Trace Contaminants↗