Search NASA⌕ Search

SEARCH · Search NASA

Results for “Calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

The structure of evaporating and combusting sprays: Measurements and predictions

An apparatus developed, to allow observations of monodisperse sprays, consists of a methane-fueled turbulent jet diffusion flame with monodisperse methanol drops injected at the burner exit. Mean and fluctuating-phase velocities, drop sizes, drop-mass fluxes and mean-gas temperatures were measured. Initial drop diameters of 100 and 180 microns are being considered in order to vary drop penetration in the flow and effects of turbulent dispersion. Baseline tests of the burner flame with no drops present were also conducted. Calibration tests, needed to establish methods for predicting drop transport, involve drops supported in the post-flame region of a flat-flame burner operated at various mixture ratios. Spray models which are being evaluated include: (1) locally homogeneous flow (LFH) analysis, (2) deterministic separated flow (DSF) analysis and (3) stochastic separated flow (SSF) analysis.

Shuen, J. S.↗

Uncertainties in hot-wire measurements of compressible turbulent flows implied by comparisons with laser-induced fluorescence

A hot-wire anemometer and a new nonintrusive laser-induced fluorescence (LIF) technique are used to survey a Mach 2 turbulent boundary layer. The hot-wire anemometer's ability to accurately measure mass flux, temperature, and density fluctuations in a compressible flow is examined by comparing its results with those obtained using LIF. Several methods of hot-wire calibration are used, and the uncertainties in their measurements of various fluctuating flow parameters are determined. The results show that although a hot-wire operated at high overheat can measure mass flux fluctuations, temperature and density fluctuations are not determined accurately from such measurements. However, a hot-wire operated at multiple overheats can be used to measure static and total temperature fluctuations. The presence of pressure fluctuations and their correlation with density can prevent the use of hot-wire data to determine density fluctuations.

Mckenzie, R. L.↗

Estimating electric field enhancement factors on an aircraft utilizing a small scale model: A method evaluation

A method for obtaining field enhancement factors at specific points on an aircraft utilizing a small scale model was evaluated by measuring several canonical shapes. Comparison of the form factors obtained by analytical means with measurements indicate that the experimental method has serious flaws. Errors of 200 to 300 percent were found between analytical values and measured values. As a result of the study, the analytical method is not recommended for calibration of field meters located on aircraft, and should not be relied upon in any application where the local spatial derivatives of the electric field on the model are large over the dimensions of the sensing probe.

Easterbrook, Calvin C.↗

Development of a numerical solution to the time dependent kinetic equation

A numerical solution was developed for the time dependent Fokker-Planck equation for arbitrary distributions of electrons injected into a magnetized plasma. The code which includes energy loss and pitch angle scattering due to Coulomb collisions and changes in pitch angle due to inhomogeneous magnetic fields was calibrated and tested. The numerical method is versatile so that other scattering or radiation terms can be easily included. Using this code many processes associated with the impulsive phase of solar flares will be investigated.

Hamilton, Russell J.↗

Precision engineering and optomechanics; Proceedings of the Meeting, San Diego, CA, Aug. 10, 11, 1989

Various papers on precision engineering and optomechanics are presented. Individual topics addressed include: performance optimization of an IR sensor optical system, design and development of a rugged airborne scanning optical assembly for a calibrated IR imaging radiometer, numerical method for Cassegrain telescope baffle design, precision alignment of an IR imaging system, optical alignment of a pupil imaging spectrometer, optical alignment equipment and methods for visible and IR imaging meteorological radiometer. Also addressed are: vibration-design aspects of an IR-scanning earth sensor, chopping secondary mirror for the Kuiper Airborne Observatory, advanced flexure suspension systems, subminiature IR detector translation stage, thermal/optical test setup for the Geostationary Operational Environmental Satellite Telescope, design of the GOES telescope secondary mirror mounting.

Vukobratovich, Daniel↗

Cryogenic far-infrared Fabry-Perot etalon

A small cryogenic Fabry-Perot etalon was fabricated for the far-infrared region. The design used freestanding metal meshes for the reflecting elements. Using a combination of gold-coated copper mesh on stainless steel. The spacing is reproduced to 1 part in 10 exp 6 with repeated cooling. The properties and methods used for alignment and calibration are presented.

Peterson, D. B.↗

Quantitative investigations of geologic surfaces utilizing airborne visible/infrared imaging spectrometer (AVIRIS) and polarimetric radar (AIRSAR) data for Death Valley, California

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) and polarimetric radar (AIRSAR) data were collected over Death Valley, California, USA, in September 1989. These two data sets were used to quantitatively characterize both the mineralogy and surface structure of the valley floor. Field mapping and characterization of the salt flats across the valley identified 16 separate units. The AVIRIS data were calibrated using the 'empirical line' method, and spectra extracted for the 16 units. A water vapor map was generated from the AVIRIS data and showed spatial variations in its distribution due to evaporation of surface water. Unmixing of the 16 spectral units produced maps of endmember abundance.

Kierein-Young, Kathryn S.↗

Direct current electrical potential measurement of the growth of small cracks

The analytical and experimental aspects of the direct-current electrical potential difference (dcEPD) method for continuous monitoring of the growth kinetics of short (50 to 500 microns) fatigue cracks are reviewed, and successful applications of the deEPD method to study fatigue crack propagation in a variety of metallic alloys exposed to various environments are described. Particular attention is given to the principle of the dcEPD method, the analytical electrical potential calibration relationships, and the experimental procedures and equipment.

Gangloff, Richard P.↗

Millimeter-wavelength observations of minor planets

Bolometer observations at 250 GHz of fifteen minor planets have shown that the emissivity of these objects is close to unity. This results in an independent method to determine the absolute calibration scale of radio observations at mm wavelengths: Applying our results to Mars, the prime calibrator at this wavelength, gives a mean absolute disk temperature at mean solar distance of approximately 210 K. Further, the diameters of circularly symmetric asteroids can be determined or the surface area of asteroids can be estimated assuming some geometric constraints on their shape.

Altenhoff, W. J.↗

High Energy Electron and Gamma - Ray Detection with ATIC

The Advanced Thin Ionization Calorimeter (ATIC) balloon borne ionization calorimeter is well suited to record and identify high energy cosmic ray electrons, and at very high energies gamma-ray photons as well. We have simulated the performance of the instrument, and compare the simulations with actual high energy electron exposures at the CERN accelerator. Simulations and measurements do not compare exactly, in detail, but overall the simulations have predicted actual measured behavior quite well. ATIC has had its first 16 day balloon flight at the turn of the year over Antarctica, and first results obtained using the analysis methods derived from simulations and calibrations will be reported.

Chang, J.↗

Material Characterization for Ductile Fracture Prediction

The research summarized in this document provides valuable information for structural health evaluation of NASA infrastructure. Specifically, material properties are reported which will enable calibration of ductile fracture prediction methods for three high-toughness metallic materials and one aluminum alloy which can be found in various NASA facilities. The task of investigating these materials has also served to validate an overall methodology for ductile fracture prediction is currently being employed at NASA. In facilitating the ability to incorporate various materials into the prediction scheme, we have provided data to enable demonstration of the overall generality of the approach.

Hill, Michael R.↗

Polar Balloon Experiment for Astrophysics Research (Polar BEAR)

A new balloon experiment is proposed for a long duration flight around the North Pole. The primary objective of the experiment is to measure the elemental energy spectra of high-energy cosmic rays in the region up to 10(exp 15) eV. The proposed instrument involves the combination of a large collecting area (approximately 1 x 1 square m) KLEM (Kinematic Lightweight Energy Meter) device with an ionization calorimeter having a smaller collecting area (approximately 0.5 x 0.5 square m) and integrated beneath the KLEM apparatus. This combination has several important advantages. Due to the large aperture (greater than 2 square m sr) of the KLEM device a large exposure factor can be achieved with a long duration balloon flight (2-4 weeks). The calorimeter will collect about 10% of the events already registered by KLEM and provide effective cross-calibration for both energy measurement methods. Details of the experiment and its astrophysical significance will be presented.

Bashindzhagyan, G.↗

Suborbital Science Program: Dryden Flight Research Center

This viewgraph presentation reviews the suborbital science program at NASA Dryden Flight Research Center. The Program Objectives are given in various areas: (1) Satellite Calibration and Validation (Cal/val)--Provide methods to perform the cal/val requirements for Earth Observing System satellites; (2) New Sensor Development -- Provide methods to reduce risk for new sensor concepts and algorithm development prior to committing sensors to operations; (3) Process Studies -- Facilitate the acquisition of high spatial/temporal resolution focused measurements that are required to understand small atmospheric and surface structures which generate powerful Earth system effects; and (4) Airborne Networking -- Develop disruption-tolerant networking to enable integrated multiple scale measurements of critical environmental features. Dryden supports the NASA Airborne Science Program and the nation in several elements: ER-2, G-3, DC-8, Ikhana (Predator B) & Global Hawk and Reveal. These are reviewed in detail in the presentation.

DelFrate, John↗

The Mid-infrared Spectrum of the Transiting Exoplanet HD 209458b

We report the spectroscopic detection of mid-infrared emission from the transiting exoplanet HD 209458b. Using archive data taken with the Spitzer IRS instrument, we have determined the spectrum of HD 209458b between 7.46 and 15.25 micrometers. We have used two independent methods to determine the planet spectrum, one differential in wavelength and one absolute, and find the results are in good agreement. Over much of this spectral range, the planet spectrum is consistent with featureless thermal emission. Between 7.5 and 8.5 m, we find evidence for an unidentified spectral feature. If this spectral modulation is due to absorption, it implies that the dayside vertical temperature profile of the planetary atmosphere is not entirely isothermal. Using the IRS data, we have determined the broadband eclipse depth to be 0:00315 +/- 0:000315, implying significant redistribution of heat from the dayside to the nightside. This work required the development of improved methods for Spitzer IRS data calibration that increase the achievable absolute calibration precision and dynamic range for observations of bright point sources.

data analysis↗

Electric Field Reconstruction in the Image Plane of a High-Contrast Coronagraph Using a Set of Pinholes around the Lyot Plane

In a setup similar to the self coherent camera, we have added a set of pinholes in the diffraction ring of the Lyot plane in a high-contrast stellar Lyot coronagraph. We describe a novel complex electric field reconstruction from image plane intensity measurements consisting of light in the coronagraph's dark hole interfering with light from the pinholes. The image plane field is modified by letting light through one pinhole at a time. In addition to estimation of the field at the science camera, this method allows for self-calibration of the probes by letting light through the pinholes in various permutations while blocking the main Lyot opening. We present results of estimation and calibration from the High Contrast Imaging Testbed along with a comparison to the pair-wise deformable mirror diversity based estimation technique. Tests are carried out in narrow-band light and over a composite 10% bandpass.

coronagraphs↗

Optical Alignment of the Global Precipitation Measurement (GPM) Star Trackers

The optical alignment of the star trackers on the Global Precipitation Measurement (GPM) core spacecraft at NASA Goddard Space Flight Center (GSFC) was challenging due to the layout and structural design of the GPM Lower Bus Structure (LBS) in which the star trackers are mounted as well as the presence of the star tracker shades that blocked line-of-sight to the primary star tracker optical references. The initial solution was to negotiate minor changes in the original LBS design to allow for the installation of a removable item of ground support equipment (GSE) that could be installed whenever measurements of the star tracker optical references were needed. However, this GSE could only be used to measure secondary optical reference cube faces not used by the star tracker vendor to obtain the relationship information and matrix transformations necessary to determine star tracker alignment. Unfortunately, due to unexpectedly large orthogonality errors between the measured secondary adjacent cube faces and the lack of cube calibration data, we required a method that could be used to measure the same reference cube faces as originally measured by the vendor. We describe an alternative technique to theodolite auto-collimation for measurement of an optical reference mirror pointing direction when normal incidence measurements are not possible. This technique was used to successfully align the GPM star trackers and has been used on a number of other NASA flight projects. We also discuss alignment theory as well as a GSFC-developed theodolite data analysis package used to analyze angular metrology data.

Hetherington, Samuel↗

Variational Asymptotic Homogenization of Finitely Deformed Viscoelastic-Viscoplastic Composites

The objective of this paper is to develop a constitutive model for finitely deformed viscoelastic-viscoplastic materials and a micromechanics approach to homogenizing composites consisting of such materials. The development of the constitutive model involves establishing a thermodynamic framework based on finite strain theory, developing a viscoelasticity and a viscoplasticity model based on the thermodynamic framework, developing a radial return algorithm based on a classic framework, and deriving a closed-from incremental constitutive relation in the spatial configuration. The development of the micromechanics approach involves pulling-back the above constitutive relation to the material configuration, formulating a variational statement with the resulting constitutive relation, discretizing variational statement in a finite-dimensional space, and solving the discretized variational statement using an Euler–Newton predictor–corrector method. The constitutive model is calibrated via monotonic uniaxial compression tests on a polymer, and the calibrated model is validated by comparing its predictions with the cyclic test data. It is shown capable of characterizing viscoelasticity, viscoplasticity, and complex loading paths. The micromechanics approach’s capabilities are demonstrated through homogenizing a unidirectional fiber-reinforced composite, subjected to uniaxial, biaxial, and shear loading, at different strain rates. It is demonstrated to be capable of handling rate dependence and complex loading paths. The present framework can be further improved by implementing more sophisticated viscoelasticity and viscoplasticity models in future work.

Finite element analysis↗

Additively Printed Flexible Temperature Sensor for Wearable Applications

The flexible sensor has the capability to be mounted on any curved surfaces of applications and be used for portable devices. Additively printed sensors have received attention owing to their compact design and ability of application to non-planar surfaces. Wearable applications require capability of integration into a variety of surfaces with ability to flex, fold, twist and stretch under the stresses of daily motion. There is scarcity of data on the interaction of the process parameters with the realized performance. In addition, there is need for data focused on sensor accuracy, repeatability, and reliability. In this study, experimental analysis on function of the fabricated sensing board is conducted. The temperature sensors are made by direct write printing method with nScrypt printer. A calibration of the sensors has been conducted to confirm that resistance is well related to actual temperature and find TCR (temperature coefficient to resistance). The evolution of resistance has been correlated with the environmental temperature. The sensor hysteresis has been quantified using upswing and downswing of the environmental temperature. In addition, the effect of humidity on the temperature sensor accuracy and performance has been quantified. The effect of a polymide coat on the sensor to prevent humidity effects has also been quantified.

Pradeep Lall↗