Search NASA⌕ Search

SEARCH · Search NASA

Results for “Composite testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Fabrication and Testing of Durable Redundant and Fluted-Core Joints for Composite Sandwich Structures

The development of durable bonded joint technology for assembling composite structures is an essential component of future space technologies. While NASA is working toward providing an entirely new capability for human space exploration beyond low Earth orbit, the objective of this project is to design, fabricate, analyze, and test a NASA patented durable redundant joint (DRJ) and a NASA/Boeing co-designed fluted-core joint (FCJ). The potential applications include a wide range of sandwich structures for NASA's future launch vehicles. Three types of joints were studied -- splice joint (SJ, as baseline), DRJ, and FCJ. Tests included tension, after-impact tension, and compression. Teflon strips were used at the joint area to increase failure strength by shifting stress concentration to a less sensitive area. Test results were compared to those of pristine coupons fabricated utilizing the same methods. Tensile test results indicated that the DRJ design was stiffer, stronger, and more impact resistant than other designs. The drawbacks of the DRJ design were extra mass and complex fabrication processes. The FCJ was lighter than the DRJ but less impact resistant. With barely visible but detectable impact damages, all three joints showed no sign of tensile strength reduction. No compression test was conducted on any impact-damaged sample due to limited scope and resource. Failure modes and damage propagation were also studied to support progressive damage modeling of the SJ and the DRJ.

Lin, Shih-Yung↗

Development of a Testbed for Pipeline Flushing - 19409

Pipelines which carry radioactive waste within the DOE complex should be properly flushed, particularly in the cases where stationary or moving beds of solid sediment occur, or lines are prone to hydrogen gas buildup. Present guidelines establish a minimum for the amount of water used for post-transfer flushing operations to achieve satisfactory cleaning of pipelines. However, further studies are needed to limit the amount of water used for flushing operations, thus minimizing the consequent downstream waste. These efforts are significantly helpful to DOE waste remediation sites by preserving tank storage, preventing additional waste processing, and minimizing dilution and changes in waste chemistry. An experimental pipe loop designed for study of non-Newtonian slurry flushing is currently being developed at the Florida International University (FIU). The testbed is designed to investigate parameters that effect the efficiency of flushing operations. The objective is to find flush velocity values/modes which lead to satisfactory cleaning of transport lines with a minimum amount of water usage. The developed methodologies will be streamlined according to the demands from both Hanford and Savannah River sites. A test matrix containing parameters such as pipeline length, flow rate, and simulant composition (solid concentration, rheology, particle size and density) has been developed. In the initial phase of testing, material composition and loop length will be fixed to a mixture of 17 wt% kaolin in water (to attain density, viscosity, and yield stress in the applicable range to operations at Savannah River and Hanford sites) and 165 feet, respectively. This matrix provides a parametric study on the flush velocity. Prescribed velocities in this test matrix comply with the maximum and minimum recommended flush velocity values by the flushing guidelines for Hanford waste (RPP-RPT-59600, Rev. 0, SRNL-STI-2015-00014, TFC-ENG-STD-26, REV C-1). Efforts will focus on creating repeatable sediment beds inside the pipeline in both fully-flooded and gravity-drained systems. Bed characterization (i.e., measurement of sediment height, solids concentration, and rheology) will be conducted to ensure consistency of initial conditions between tests. A combination of Pulse-Echo technique, Coriolis meter, and optical inspections will be used to accomplish initial bed characterization (ensuring consistency between tests), control/monitor density variations (initial bed creation, flush velocity control, and post-flush evaluations), and serve as reference (validation of PulseEcho and pipe surface cleanness evaluation), respectively. This paper will present the details of the development of the test loop and the test matrix. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Material Total Mass Loss in Vacuum Obtained From Various Outgassing Systems

Several instruments including the Cahn Microbalance, the Knudsen Cell, the micro-CVCM, and the vacuum Thermogravimetric Analyzer (TGA) were used in the testing of a graphite/epoxy (GR/EP) composite that is proposed for use as a rigidizing element of an inflatable deployment system. This GR/EP will be cured in situ. The purpose of this testing is to estimate the gaseous production resulting from the curing of the GR/EP composite, to predict the resulting pressure, and to calculate the required venting. Every test was conducted under vacuum at 125 degrees C for 24 hours. Upon comparison of the results, the ASTM E-595 was noted to have given readings that were consistently lower than those obtained using the other instruments, which otherwise provided similar results. The GR/EP was tested using several different geometric arrangements. This paper describes the analysis evaluating the molecular and continuum flow of the outgassing products issuing from the exit port of the ASTM E-595 system. The effective flow conductance provided by the physical dimensions of the vent passage of the ASTM E-595 system and that of the material sample among other factors were investigated to explain the reduced amount of outgassing released during the 24-hour test period.

Scialdone, John↗

Design, Manufacture and Test of Cryotank Components

On the composite cryotank technology development (CCTD) project, the Boeing Company built two cryotanks as a means of advancing technology and manufacturing readiness levels (TRL and MRL) and lowering the risk of fabricating full-scale fuel containment vessels.1 CCTD focused on upper stage extended duration applications where long term storage of propellants is required. The project involved the design, analysis, fabrication, and test of manufacturing demonstration units (MDU), a 2.4 m (precursor) and a 5.5 m composite cryotank. Key design features included one-piece wall construction to minimize overall weight (eliminating the need for a bellyband joint), 3-dimensionally (3D) reinforced y-joint material to alleviate stress concentrations at the tank to skirt interface and a purge-able fluted core skirt to carry high axial launch loads. The tanks were made with OoA curing pre-impregnated (prepreg) carbon/epoxy (C/E) slit-tape tow (STT) that contained thin micro-crack resistant plies in the tank wall center to impede permeation. The tanks were fabricated at Boeing's Seattle-based Advanced Development Center (ADC) using RAFP and multipiece break-down tooling. The tooling was designed and built by Janicki Industries (JI) at Sedro Woolley, Washington. Tank assemblage consisted of co-bonded dome covers, one-piece fluted core skirts and mechanical fastened cover/sump. Ultrasonic inspection was performed after every cure or bond and a structural health monitoring system (SHMS) was installed to identify potential impact damage events (in-process and/or during transportation). The tanks were low temperature tested at NASA's George C. Marshall Space Flight Center (MSFC) in Huntsville, Alabama. The testing, which consisted of a sequence of fill/drain pressure and thermal cycles using LH2, was successfully concluded in 2012 on the 2.4 m tank and in 2014 on the 5.5 m tank. Structural, thermal, and permeation performance data was obtained. 2 Critical design features and manufacturing advancements, which helped to validate 25% weight and 30% cost reduction projections, were matured. These advancements will help to guide future composite tank integration activities on next generation long duration aircraft and space launch vehicles. Because CCTD addressed innovative design features, heavy lift size scale-up, multipiece captured tooling, new generation automated material placement (AMP) equipment and OoA materials, this chapter should be of interest to educators, students and manufacturers of composite hardware and flight vehicles.

McCarville, Douglas A.↗

Composite Overwrapped Pressure Vessel (COPV) Damage Tolerance Life Analysis Methodology and Test Best Practices

The NASA Engineering and Safety Center (NESC) Deputy Director requested an independent assessment to develop data to understand the limitations of linear elastic fracture mechanics (LEFM) computational methods used to predict fatigue crack growth rate (da/dN) behavior of small detectable cracks in thin metal liners for composite overwrapped pressure vessels (COPVs). The NESC assessment team was also requested to demonstrate a test-based methodology for validating damage tolerance requirements for COPVs with elastically responding metal liners where LEFM methods are not appropriate. This report contains the outcome of the NESC assessment.

Composite Overwrapped Pressure Vessels; Linear Ela↗

Degradation in interfacial shear strength of carbon fiber/ vinyl ester composites due to long-term exposure to seawater using push-out tests

Here, in this study, single fiber (~7-μm diameter) push-out tests are conducted to evaluate hygrothermal effects on the interfacial shear strength (IFSS) of carbon fiber/vinyl ester (CF/VE) composites. Hygrothermal conditioning is achieved by saturating samples in simulated seawater at 40 °C for two years. An investigation has been conducted on the preparation, validity, and interpretation of the push-out test results. First, the authors present a polishing methodology that results in thin films of CF/VE composites in the thickness range of 15–120 μm and produces an average 41.2% drop in IFSS due to long-term hygrothermal exposure. Using scanning electron microscopy (SEM), we show that during the push-out tests, the failure initiates locally at the zone of minimum bond strength at the bottom (away from the indenter), then propagates along the length of the interface. The influence of radial tensile stresses originating due to bending is found to be negligible. Using the SEM imaging of the pushed-out fibers, we validate the failure of the interface to be the primary source of failure. The associated results are found to depend on the thickness of the interface. We then reevaluate the results using the Weibull distribution, knowing that the failure mechanism is analogous to the weakest link theory. The results show a 25.5% drop in the IFSS of the CFVE composite, measured at an infinitesimal scale due to long-term to hygrothermal conditioning at 40 °C. A significant drop in IFSS was observed after reheating above glass transition temperature (T g ) and cooling.

36 MATERIALS SCIENCE↗

IACMI Project 4.2: Thermoplastic Composite Development for Wind Turbine Blades

(Section 5.1) Composites made from Arkema’s Elium® thermoplastic resin and Johns Manville fiberglass were researched during this project for applications in wind blade manufacturing. A techno-economic model was developed to model this wind blade manufacturing process using these materials in place of traditional composites made with thermoset resin. This model was based on manufacturing a 61.5-meter wind blade, which showed a 4.7% reduction in wind blade cost as compared traditional thermoset materials. These cost savings were not from the thermoplastic material costing less than traditional thermoset materials, but rather from decreased capital costs, faster cycle times and reduced energy requirements and labor costs. (Section 5.2) An infusion and curing model was developed for thermoplastic composite wind blades using PAM-RTM. The primary goal was to demonstrate the infusion simulation for the Elium® resin system on a 13-meter wind blade. Additionally, the exotherm temperature was predicted and compared to measurements, which showed model results within 10% of actual measurements. (Section 5.3) Composite laminate panels and composite sandwich panels with a balsa core were produced; specimens were cut and characterized. Similar composite specimens were made with Elium® thermoplastic resin and Hexion thermoset epoxy (RIMR135/RIMH1366) to enable comparisons between these resin systems. The static test methods included: tensile, compression, in-plane shear, interlaminar shear, flexural, sandwich core shear flexure, and single cantilever beam tests for sandwich beams. Fatigue testing at room temperature was completed to composite laminate panels at a stress ratio of R=0.1 and R=10. In addition, fatigue testing to laminate panels was completed at -30°C, and at room temperature after conditioning specimens at 70°C and 90% relative humidity. Overall, mechanical test results from Elium® composites are similar to epoxy composites. (Section 5.4) Elium composite panels were produced with intentional defects such as voids and nonwetting of fibers to begin to understand performance sensitivity to defects. A thermal digital image correlation (TDIC) method provides high spatial resolution strain field at elevated temperatures and can be used to identify defective regions within composite panels. Flexural modulus differences of 21% were seen between defect and non-defect panels. Other Elium® composite panels were forced to be defective by boiling the resin after infusion, which created voids throughout the composite laminate. X-ray computed tomography scanning was used to view the internal structure of the defect panels. Defect panels had a significant reduction in fatigue life as compared to baseline panels produced without intentional defects. (Section 5.5) Lap shear specimens were fabricated to compare the lap shear strength of an off-the-shelf adhesive (Plexus MA590) and two new adhesives developed by Arkema (Bostik SAF30 90 and Bostik SAF30 120). ISO standard 4587:2003 was used to standardize the testing method and sample fabrication. Lap shear specimens were made at 1mm, 3mm, and 10mm thicknesses. The Bostik adhesive lap shear test results were similar to Plexus for all thicknesses. (Section 5.6) Fiber-reinforced polymer (FRP) composites are typically used in high-performance applications (e.g., aerospace), and their expansion into high-volume industries (e.g. consumer automotive and wind turbine blade manufacturer or similar) is hindered by their cost and a lack of efficient manufacturing techniques. Monitoring the curing process of these composites during manufacturing can improve the efficiency of the process, and therefore reduce the manufacturing cost. Cure monitoring techniques were developed that use probabilistic estimation methods and surface temperature measurements made using infrared cameras. These techniques enable real-time monitoring of the infusion process to locate manufacturing flaws, and they can, potentially, estimate residual stresses in the part. Their commercialization will help facilitate expansion of FRP composites in high-volume industries. (Section 5.7) A 13-meter composite wind blade was produced with Elium® resin and Johns Manville fiberglass; this blade was made with VARTM processing similar to how megawatt-scale wind blades are currently manufactured, but no post-mold heating was used for this thermoplastic composite blade. The wind blade underwent full-scale validation for static loading (4-different load orientations) and flapwise fatigue loading to simulate 20-years of operational loads. The thermoplastic composite wind blade withstood the loading without any noted issues and performed similar to results from a previous full-scale validation to an equivalent epoxy composite wind blade produced with the same blade molds. (Section 5.8) A study was conducted to determine the feasibility of recycling composite wind turbine blade components fabricated with glass fiber reinforced Elium® thermoplastic resin. Dissolution, which is a process unique to thermoplastic matrices, allows recovery of both the polymer matrix and full-length glass fibers, while maintaining their stiffness and strength throughout the recovery process. The economics of recycling is favorable if 50% of the glass fiber is recovered and resold for a process of $\$$ 0.28/kg, and 90% of the resin is recovered and resold at a price of $\$$ 2.50/kg.(Section 10) Recommendations are outlined for commercializing thermoplastic resin for composite wind blade production, in addition to recommended areas for future research.

17 WIND ENERGY↗

Using Tabulated Experimental Data to Drive an Orthotropic Elasto-Plastic Three-Dimensional Model for Impact Analysis

An orthotropic elasto-plastic-damage three-dimensional model with tabulated input has been developed to analyze the impact response of composite materials. The theory has been implemented as MAT 213 into a tailored version of LS-DYNA being developed under a joint effort of the FAA and NASA and has the following features: (a) the theory addresses any composite architecture that can be experimentally characterized as an orthotropic material and includes rate and temperature sensitivities, (b) the formulation is applicable for solid as well as shell element implementations and utilizes input data in a tabulated form directly from processed experimental data, (c) deformation and damage mechanics are both accounted for within the material model, (d) failure criteria are established that are functions of strain and damage parameters, and mesh size dependence is included, and (e) the theory can be efficiently implemented into a commercial code for both sequential and parallel executions. The salient features of the theory as implemented in LS-DYNA are illustrated using a widely used composite - the T800S/3900-2B[P2352W-19] BMS8-276 Rev-H-Unitape fiber/resin unidirectional composite. First, the experimental tests to characterize the deformation, damage and failure parameters in the material behavior are discussed. Second, the MAT213 input model and implementation details are presented with particular attention given to procedures that have been incorporated to ensure that the yield surfaces in the rate and temperature dependent plasticity model are convex. Finally, the paper concludes with a validation test designed to test the stability, accuracy and efficiency of the implemented model.

Polymer Matrix Composites↗

Composite Overwrapped Pressure Vessel (COPV) Damage Tolerance Life Analysis Methodology and Test Best Practices: Appendices

The NASA Engineering and Safety Center (NESC) Deputy Director requested an independent assessment to develop data to understand the limitations of linear elastic fracture mechanics (LEFM) computational methods used to predict fatigue crack growth rate (da/dN) behavior of small detectable cracks in thin metal liners for composite overwrapped pressure vessels (COPVs). The NESC assessment team was also requested to demonstrate a test-based methodology for validating damage tolerance requirements for COPVs with elastically responding metal liners where LEFM methods are not appropriate. This document contains the appendices to the main report.

Composite Overwrapped Pressure Vessels; Linear Ela↗

Effect of rolling on the high temperature tensile and stress-rupture properties of tungsten fiber-superalloy composites

An investigation was conducted to determine the effects of mechanical working on the 1093 C (2000 F) tensile and stress-rupture strength of tungsten alloy/superalloy composites. Hot pressed composites containing either conventional tungsten lamp filament wire or tungsten-1% ThO2 wire and a nickel base alloy matrix were hot rolled at 1093 C (2000 F). The hot pressed and rolled composite specimens were then tested in tension and stress-rupture at 1093 C (2000 F). Rolling decreased the degree of fiber-matrix reaction as a function of time of exposure at 1093 C (2000 F). The stress-rupture properties of the rolled composites were superior to hot pressed composites containing equivalent diameter fibers. Rolling did not appreciably affect the 1093 C (2000 F) ultimate tensile strength of the composites.

Petrasek, D. W.↗

Creep and creep rupture of strongly reinforced metallic composites

A creep and creep damage theory is presented for metallic composites with strong fibers. Application is to reinforced structures in which the fiber orientation may vary throughout but a distinct fiber direction can be identified locally (local transverse isotropy). The creep deformation model follows earlier work and is based on a flow potential function that depends on invariants reflecting stress and the material symmetry. As the focus is on the interaction of creep and damage, primary creep is ignored. The creep rupture model is an extension of continuum damage mechanics and includes an isochronous damage function that depends on invariants specifying the local maximum transverse tension and the maximum longitudinal shear stress. It is posited that at high temperature and low stress, appropriate to engineering practice, these stress components damage the fiber/matrix interface through diffusion controlled void growth, eventually causing creep rupture. Experiments are outlined for characterizing a composite through creep rupture tests under transverse tension and longitudinal shear. Application is made to a thin-walled pressure vessel with reinforcing fibers at an arbitrary helical angle. The results illustrate the usefulness of the model as a means of achieving optimal designs of composite structures where creep and creep rupture are life limiting.

Robinson, D. N.↗

IMPACT OF SMALL COLUMN ION EXCHANGE STREAMS ON DWPF GLASS FORMULATION MELT RATE STUDIES

This study was undertaken to evaluate the potential impacts of the Small Column Ion Exchange (SCIX) streams - particularly the addition of Monosodium Titanate (MST) and Crystalline Silicotitanate (CST) - on the melt rate of simulated feed for the Defense Waste Processing Facility (DWPF). Additional MST was added to account for contributions from the Salt Waste Processing Facility (SWPF). The Savannah River National Laboratory (SRNL) Melt Rate Furnace (MRF) was used to evaluate four melter feed compositions: two with simulated SCIX and SWPF material and two without. The Slurry-fed Melt Rate Furnace (SMRF) was then used to compare two different feeds: one with and one without bounding concentrations of simulated SCIX and SWPF material. Analyses of the melter feed materials confirmed that they met their targeted compositions. Four feeds were tested in triplicate in the MRF. The linear melt rates were determined by using X-ray computed tomography to measure the height of the glass formed along the bottom of the beakers. The addition of the SCIX and SWPF material reduced the average measured melt rate by about 10% in MRF testing, although there was significant scatter in the data. Two feeds were tested in the SMRF. It was noted that the ground CST alone (ground CST with liquid in a bucket) was extremely difficult to resuspend during preparation of the feed with material from SCIX and SWPF. This feed was also more difficult to pump than the material without MST and CST due to settling occurring in the melter feed line, although the yield stress of both feeds was high relative to the DWPF design basis. Steady state feeding conditions were maintained for about five hours for each feed. There was a reduction in the feed and pour rates of approximately 15% when CST and MST were added to the feed, although there was significant scatter in the data. Analysis of samples collected from the SMRF pour stream showed that the composition of the glass changed as expected when MST and CST were added to the feed. These reductions in melt rate are consistent with previous studies that showed a negative impact of increased TiO{sub 2} concentrations on the rate of melting. The impact of agitating the melt pool via bubbling was not studied as part of this work, but may be of interest for further testing. It is recommended that additional melt rate testing be performed should a potential reduction in melt rate of 10-15% be considered an issue of concern, or should the anticipated composition of the glass with the addition of material from salt waste processing be modified significantly from the current projections, either due to changes in sludge batch preparation or changes in the composition or volume of SCIX and SWPF material.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Task 60 test report, evaluation of IRIG-A 21 channel constant bandwith FM multiplexer for shuttle development flight instrumentation

A frequency modulated (FM) multiplexer, consisting of 21 IRIG-A constant bandwidth (CBW) voltage-controlled oscillators (VCO's) was tested to determine its suitability for use in multiplexing 21 data signals which have frequency ranges of dc to 2 kHz. Tests were preformed with the composite signal, consisting of the mixed outputs of the 21 VCO's connected directly to a set of subcarrier discriminators, with the signal recorded on magnetic tape and played back through the discriminators and with the signal transmitted by a frequency-modulated FM S-band radio frequency RF transmitter to a FM receiver and through the subcarrier discriminators. Tape speed flutter was induced to determine the reduction in flutter noise which can be obtained by the tape speed compensation equipment. The RF transmission test included transmitting the composite signal at a nominal RF received signal of -73 dbm and at RF levels of -83 and -86 dbm.

Haddick, C. M.↗

Lifetimes of fiber composites under sustained tensile loading

A description is presented of the test techniques which have been used to apply sustained uniaxial tensile loading to fiber/epoxy composites. The fiber types used include S-glass, aramid, graphite, and beryllium wire. The applied load vs lifetime data for four composite materials are presented in graphs. Attention is given to a statistical analysis of data, a performance comparison of various composites, the age effect on the strength of composites, the applicability of the lifetime data to complex composites, and aspects of accelerated test method development. It is found that the lifetime of a composite under a sustained load varies widely. Depending on the composite system, the minimum life typically differs from the maximum life by a factor of 100 to 1000. It is in this connection recommended that a use of average life data should be avoided in serious design calculations.

Chiao, T. T.↗

An All-Ceramic, Anisotropic, and Flexible Aerogel Insulation Material

To exploit the high-temperature superinsulation potential of anisotropic thermal management materials, the incorporation of ceramic aerogel into the aligned structural networks is indispensable. Yet, the long-standing obstacle to exploring ultralight superinsulation ceramic aerogels is the inaccessibility of its mechanical elasticity, stability, and anisotropic thermal insulation. Here, we report a recoverable, flexible ceramic fiber-aerogel composite with anisotropic lamellar structure, where the interfacial cross-linking between ceramic fiber and aerogel is important in its superinsulation performance. The resulting ultralight aerogel composite exhibits a density of 0.05 g/cm 3 , large strain recovery (over 50%), and low thermal conductivity (0.0224 W m –1 K –1 ), while its hydrophobicity is achieved by in situ trichlorosilane coating with the water contact angle of 135°. The hygroscopic tests of such aerogel composites demonstrate a reversible thermal insulation. The mechanical elasticity and stability of the anisotropic composites, with its soundproof performance, shed light on the low-cost superelastic aerogel manufacturing with scalability for energy saving building applications.

36 MATERIALS SCIENCE↗

Creep/Stress Rupture Behavior of 3D Woven SiC/SiC Composites with Sylramic-iBN, Super Sylramic-iBN and Hi-Nicalon-S Fibers at 2700F in Air

To determine the influence of fiber types on creep durability, 3D SiC/SiC CMCs were fabricated with Sylramic-iBN, super Sylramic-iBN and Hi-Nicalon-S fibers and the composite specimens were then tested under isothermal tensile creep at 14820C at 69, 103 and 138 MPa for up to 300hrs in air. The failed specimens were examined by scanning electron microscopy (SEM) and computed tomography (CT) for fracture mode analysis. The creep data of these composites are compared with those of other SiC/SiC composites in the literature. The results of this study will be presented.

failure modes↗

Creep and Cyclic Fatigue Durability of 3D Woven SiC/SiC Composites with (CVI+PIP) Hybrid Matrix

SiC-SiC composites are potential candidate materials for turbine components such as combustor liners, nozzle vanes and blades because of their low density, high temperature capability, and tailorable mechanical properties. The first generation of SiC-SiC composites fabricated by melt infiltration are being introduced in current engines. These materials are limited to 1315 degrees Centigrade applications because of the presence of residual silicon in the SiC matrix. Currently there is an increasing interest in developing SiC-SiC composites without silicon for structural aerospace applications above 1315 degrees Centigrade. The developmental 3D woven SiC-SiC composites with Chemical Vapor Infiltration plus Polymer Impregnation and Pyrolysis (CVI+PIP) hybrid matrix show potential for 1482 degrees Centigrade applications. In this study 3D woven SiC-SiC composite specimens were creep tested at 1482 degrees Centigrade at different stress levels until failure or for 1000 hours without failure. The failed specimens were analyzed for under a scanning electron microscope to assess the damage mechanisms. The creep data of 3D woven SiC-SiC composites with (CVI+PIP) hybrid matrix were compared with those of full CVI SiC-SiC composites and sintered SiC from the literature. The potential benefits limitations and durability of 3D woven SiC-SiC composites for turbine applications will be discussed.

creep durability↗