Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Model, Design, and Control for Power Conversion in Wave Energy Converter System

Wave energy, if all been harvested along the U.S. coastline, can power around 65% of the energy consumption in U.S.. Comparing to other renewable energy sources like solar or wind, ocean wave can provide up to 90% of steady uptime. With the high energy density (2-3 kW/m 2 ), it can produce more energy with the same amount of installation area comparing to the energy density of wind turbine (0.6 kW/m 2 ) and solar panel(0.2 kW/m 2 ). The predictability of wave provides advantages like planning installation, power dispatching, and maintenance activities. Although with all these advantages, wave energy converter system is still in the research stage due to its high system cost per electricity production. One of the challenges that need to be solved is the irregularity from the wave motion that leads to high instantaneous peak power into the wave energy converter, which usually reaches up to 10 - 20 times of the average power. The high peak power will not only bring high mechanical/electrical stress but also result in an overrating design of the components in the system. Another obstacle that prevents the wave energy system from moving forward is the high testing cost from the validations in wave-energy-test sites or tank-test sites. A high-fidelity multi-disciplinary system model, including hydrodynamics, mechanical dynamics, electromagnetics, and power electronics, is needed to predict the behavior of the system and reduce the cost of design validation.

16 TIDAL AND WAVE POWER↗

Parareal in time 3D numerical solver for the LWR Benchmark neutron diffusion transient model

In this paper we present a time-parallel algorithm for the 3D neutrons calculation of a transient model in a nuclear reactor core. The neutrons calculation consists in numerically solving the time dependent diffusion approximation equation, which is a simplified transport equation. The numerical resolution is done with finite elements method based on a tetrahedral meshing of the computational domain, representing the reactor core, and time discretization is achieved using a θ-scheme. The transient model presents moving control rods during the time of the reaction. Therefore, cross-sections (piecewise constants) are taken into account by interpolations with respect to the velocity of the control rods. The parallelism across the time is achieved by an adequate use of the parareal in time algorithm to the handled problem. This parallel method is a predictor corrector scheme that iteratively combines the use of two kinds of numerical propagators, one coarse and one fine. Our method is made efficient by means of a coarse solver defined with large time step and fixed position control rods model, while the fine propagator is assumed to be a high order numerical approximation of the full model. The parallel implementation of our method provides a good scalability of the algorithm. Numerical results show the efficiency of the parareal method on large light water reactor transient model corresponding to the Langenbuch–Maurer–Werner benchmark.

97 MATHEMATICS AND COMPUTING↗

Digital flight control design using implicit model following.

A design procedure for determining the control gains of a discrete-time ('digital') control system is presented. The method is separable into four distinct steps: (1) the definition of closed-loop response criteria, (2) the choice of a discrete-time model which provides the desired response, (3) the determination of control gains which implicitly force the actual system to follow the desired response, and (4) the reduction of the measurement state by the introduction of an 'observer' (a form of integral-differential compensation). It is shown that a single desired response does not completely define the 'ideal' system. The response criterion generally leaves some parameters of the model unspecified, allowing two courses for improving the model: (1) definition of additional response criteria, or (2) redefinition of the discrete-time model for improved implicit model-following with the actual closed-loop system.

Stengel, R. F.↗

Power System Frequency Dynamics Modeling, State Estimation, and Control using Neural Ordinary Differential Equations (NODEs) and Soft Actor-Critic (SAC) Machine Learning Approaches

With the global energy transition of the electric power system, grid control, supervision, and protection is becoming more challenging. With the increasing integration of renewable energy sources (RES), the system dynamics are changing, causing traditional power system dynamic modeling with swing equation-based modeling approaches to fail. Additionally, the converter-dominated power grid is decreasing the system inertia, making the power system more fragile to the frequency swings. This paper first investigates and compares the application of a model-based Kalman filter state estimation approach with (i) a model-free machine learning approach --- neural ordinary differential equations (NODEs) --- and (ii) a data-driven system identification (SysId) approach to model and infer critical state values of the power system frequency dynamics. Then a model predictive control (MPC) framework is compared to a model-free Soft Actor-Critic (SAC) reinforcement learning (RL) control algorithm in providing efficient fast frequency response (FFR) to the power system frequency dynamics. The approaches are compared in terms of their performance goals as well as their per-timestep computational efficiency. Furthermore, the comparative study for state estimation shows that for the model-free requirement, both NODEs and SysId can provide accurate state estimates; however, with increasing model complexity, NODEs can be a better choice for model identification. Similarly, the results from the FFR comparative study show that the SAC RL-based FFR, once trained, outperforms MPC with better control signals and faster computation time, making the SAC RL-based FFR better option for providing FFR to the power system.

97 MATHEMATICS AND COMPUTING↗

Model Identification of Inverter Nonlinear Control Dynamics

To comprehensively predict in silico potential disruptive dynamic performance of converter-based generation and develop solutions, the application of electromagnetic transient programs is desirable. However, these accurate simulations highly depend on inverter models of actual field implementations, which are often unavailable because they are proprietary. To address this problem, we propose a time-domain model identification method that can be used to determine the control models of inverters in continuous time from multiple experimental studies. The focus is on identifying the dynamic representation of controls because they dominate the dynamic response of renewable assets. To illustrate the applicability of the technique, we consider a subclass of inverter controllers for autonomous grid applications that rely on nonlinear oscillators.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparative Study and Accommodation of Biodiesel in Diesel‐Electric Hybrid Vehicles Coupled with Aftertreatment Systems

Abstract Biodiesel is a promising renewable alternative fuel, which can be used in diesel‐electric hybrid vehicles to potentially bring one kind of clean vehicle on the road. However, the fuel property variation can cause impacts to the powertrain and aftertreatment systems. In this paper, biodiesel's influence on post‐injection effects is studied. Experimental results are obtained to demonstrate the differences between diesel and biodiesel, and to build up fuel‐dependent maps of engine torque, temperature, and emissions. Utilizing those maps, an aftertreatment warm‐up approach compatible with both fuels is developed by strategically enabling double post injections. Finally, a supervisory controller based on model predictive control method is designed to optimize and balance the tradeoff between hybrid vehicle fuel economy and tailpipe emissions. Simulations are conducted for both fuels with or without the proposed control strategy. The validation results show that for both fuels, the controller can significantly reduce tailpipe emissions by successfully regulating the catalyst temperature to the desired range sacrificing fuel economy. And for biodiesel, additional fuel cost is required in order to realize the tradeoff.

Zhao, Junfeng↗

Equation-based object-oriented modeling and simulation of data center cooling systems

In this paper, we introduce a newly developed open source data center package in the Modelica Buildings library to support modeling and simulation of cooling and control systems of data centers. The data center package contains major thermal and control component models, such as Computer Room Air Handler, Computer Room Air Conditioner, models of different subsystem configurations such as chillers with differently configured waterside economizers, as well as templates for different systems. Two case studies based on this package are performed to investigate the performances of the cooling and electrical system under normal conditions and emergency situations such as a blackout: one is for a data center powered by conventional energy, and the other is for a data center powered by renewable energy. Simulation results show that the dynamic modeling and multi-domain simulation in the Modelica-based tool make it convenient for users to investigate both normal and emergent operations for conventional and renewable data centers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Recovery of lithium and cobalt from waste lithium ion batteries of mobile phone

Graphical abstract: Recovery of valuable metals from scrap batteries of mobile phone. - Highlights: • Recovery of Co and Li from spent LIBs was performed by hydrometallurgical route. • Under the optimum condition, 99.1% of lithium and 70.0% of cobalt were leached. • The mechanism of the dissolution of lithium and cobalt was studied. • Activation energy for lithium and cobalt were found to be 32.4 kJ/mol and 59.81 kJ/mol, respectively. • After metal recovery, residue was washed before disposal to the environment. - Abstract: In view of the stringent environmental regulations, availability of limited natural resources and ever increasing need of alternative energy critical elements, an environmental eco-friendly leaching process is reported for the recovery of lithium and cobalt from the cathode active materials of spent lithium-ion batteries of mobile phones. The experiments were carried out to optimize the process parameters for the recovery of lithium and cobalt by varying the concentration of leachant, pulp density, reductant volume and temperature. Leaching with 2 M sulfuric acid with the addition of 5% H{sub 2}O{sub 2} (v/v) at a pulp density of 100 g/L and 75 °C resulted in the recovery of 99.1% lithium and 70.0% cobalt in 60 min. H{sub 2}O{sub 2} in sulfuric acid solution acts as an effective reducing agent, which enhance the percentage leaching of metals. Leaching kinetics of lithium in sulfuric acid fitted well to the chemical controlled reaction model i.e. 1 − (1 − X){sup 1/3} = k{sub c}t. Leaching kinetics of cobalt fitted well to the model ‘ash diffusion control dense constant sizes spherical particles’ i.e. 1 − 3(1 − X){sup 2/3} + 2(1 − X) = k{sub c}t. Metals could subsequently be separated selectively from the leach liquor by solvent extraction process to produce their salts by crystallization process from the purified solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗