Search NASA⌕ Search

SEARCH · Search NASA

Results for “DETECTOR PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Searches for leptoquark production and compositeness at the Tevatron

Recent searches for leptoquark production and compositeness in p{bar p} collisions at {radical}s = 1.96TeV are presented using data samples with integrated luminosities up to 4fb{sup -1} recorded with the D0 and CDF detectors at the Tevatron collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A New Inelastic Neutron Spectrometer HODACA

In this study, a new multiplex-type inelastic neutron scattering spectrometer, HOrizontally Defocusing Analyzer Concurrent data Acquisition spectrometer (HODACA), was recently developed and built at the C1-1 cold neutron beam port in the neutron source reactor JRR-3 at Japan Atomic Energy Agency. The spectrometer is suitable for dynamics measurements in the energy range of -1 meV ≲ ℏω ≲ 7 meV, catering to a broad array of research fields in physics and material science. HODACA combines 24 detectors and 132 pieces of analyzer crystals and has an estimated measurement efficiency that is 70 times greater than the existing conventional triple-axis spectrometer at the C1-1 beam port. The concept, design, specification, and results of commissioning experiments are described.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Participation of JINR in the CDF Experiment

Participation of a Joint Institute for Nuclear Research (JINR) team in the research program at the Tevatron at Fermilab is described. In their work on the upgraded CDF Run II detector, the emphasis was placed on top quark physics. The JINR team was fully engaged in the data analysis of the CDF experiment, particularly, in measuring the top quark mass in the dilepton and lepton-jet modes, in measuring the top quark charge, and in searching for the Higgs boson. The JINR team made a decisive contribution to the operation of the scintillation counter subsystem of the CDF muon trigger, to the trigger based on the vertex silicon detector for selection of events with secondary vertices and to the preshower detector of the electromagnetic calorimeter. The team was involved in the construction, upgrading, and operation of the system of scintillation counters and developed a system for the online monitoring of their parameters to ensure their effective operation in Run II. The work of the JINR researchers was highly appreciated by the international CDF collaboration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

Novel Materials and Devices for Solid-State Neutron Detection

There is a need in many fields, such as nuclear medicine, non-proliferation, energy exploration, national security, homeland security, nuclear energy, etc, for miniature, thermal neutron detectors. Until recently, thermal neutron detection has required physically large devices to provide sufficient neutron interaction and transduction signal. Miniaturization would allow broader use in the fields just mentioned and open up other applications potentially. Recent research shows promise in creating smaller neutron detectors through the combination of high-neutron-cross-section converter materials and solid-state devices. Yet, till recently it is difficult to measure low neutron fluxes by solidstate means given the need for optimized converter materials (purity, chemical composition and thickness) and a lack of designs capable of efficient transduction of the neutron conversion products (x-rays, electrons, gamma rays). Gadolinium-based semiconductor heterojunctions have detected electrons produced by Gd-neutron reactions but only at high neutron fluxes. One of the main limitations to this type of approach is the use of thin converter layers and the inability to utilize all the conversion products. In this LDRD we have optimized the converter material thickness and chemical composition to improve capture of conversion electrons and have detected thermal neutrons with high fidelity at low flux. We are also examining different semiconductor materials and converter materials to attempt to capture a greater percentage of the conversion electrons, both low and higher energy varieties. We have studied detector size and bias scaling, and cross-sensitivity to xrays and shown that we can detect low fluxes of thermal neutrons in less than 30 minutes with high selectivity by our approach. We are currently studying improvements in performance with direct placement of the Gd converter on the detector. The advancement of sensitive, miniature neutron detectors will have benefits in energy production, nonproliferation and medicine.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A practical guide to unbinned unfolding

Unfolding, in the context of high-energy particle physics, refers to the process of removing detector distortions in experimental data. The resulting unfolded measurements are straightforward to use for direct comparisons between experiments and a wide variety of theoretical predictions. For decades, popular unfolding strategies were designed to operate on data formatted as one or more binned histograms. In recent years, new strategies have emerged that use machine learning to unfold datasets in an unbinned manner, allowing for higher-dimensional analyses and more flexibility for current and future users of the unfolded data. This guide comprises recommendations and practical considerations from researchers across a number of major particle physics experiments who have recently put these techniques into practice on real data.

Canelli, Florencia [Univ. of Zurich (Switzerland)]↗

Sci—Fri PM: Dosimetry—05: Megavoltage electron backscatter: EGSnrc results versus 21 experiments

The accuracy of electron backscatter calculations at megavoltage energies is important for many medical physics applications. In this study, EGSnrc calculations of megavoltage electron backscatter (1–22 MeV) are performed and compared to the data from 21 experiments published between 1954 and 1993 for 25 single elements with atomic numbers from 3 to 92. Typical experimental uncertainties are 15%. For EGSnrc simulations, an ideal detector is assumed, and the most accurate electron physics options are employed, for a combined statistical and systematic uncertainty of 3%. The quantities compared are the backscatter coefficient and the energy spectra (in the backward hemisphere and at specific detector locations). For the backscatter coefficient, the overall agreement is within ±2% in the absolute value of the backscatter coefficient (in per cent), and within 11% of the individual backscatter values. EGSnrc results are systematically on the higher end of the spread of the experimental data, which could be partially from systematic experimental errors discussed in the literature. For the energy spectra, reasonable agreement between simulations and experiments is observed, although there are significant variations in the experimental data. At the lower end of the spectra, simulations are higher than some experimental data, which could be due to reduced experimental sensitivity to lower energy electrons and/or over-estimation by EGSnrc for backscattered secondary electrons. In conclusion, overall good agreement is observed between EGSnrc backscatter calculations and experimental measurements for megavoltage electrons. There is a need for high quality experimental data for the energy spectra of backscattered electrons.

60 APPLIED LIFE SCIENCES↗

Underlying Event Studies at ATLAS and CDF

Improving our understanding and modeling of the underlying event in high energy collider environment is important for more precise measurements at the LHC. CDF Run II data for the underlying event associated with Drell-Yan lepton pair production and early ATLAS data measuring underlying event activity with respect to the leading transverse momentum track are presented. The data are compared with several QCD Monte Carlo models. It is seen that no current standard Monte Carlo tune adequately describes all the early ATLAS data and CDF data simultaneously. The underlying event observables presented here are particularly important for constraining the energy evolution of multiple parton interaction models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-I-55: Performance Evaluation of Digital PET/CT: Medical Physics Basis for the Clinical Applications

Purpose: Replacement of conventional PMT-based detector with next generation digital photon counting (DPC) detector is a technology leap for PET imaging. This study evaluated the performance and characteristics of the DPC system and its stability within a 1 year time window following its installation focusing on the medical physics basis for clinical applications. Methods: A digital PET/CT scanner using 1:1 coupling of 23,040 crystal: detector elements was introduced and became operational at OSU. We tested and evaluated system performance and characteristics using NEMA NU2-2012. System stabilities in timing resolution, energy resolution, detector temperature and humidity (T&H) were monitored over 1-yr. Timing, energy and spatial resolution were characterized across clinically relevant count rate range. CQIE uniformity PET and NEMA IEC-Body PET with hot spheres varying with sizes and contrasts were performed. PET reconstructed in standard(4mm), High(2mm) and Ultra-High(1mm) definitions were evaluated. Results: NEMA results showed PET spatial resolution (mm-FWHM) from 4.01&4.14 at 1cm to 5.82&6.17 at 20cm in transverse & axial. 322±3ps timing and 11.0% energy resolution were measured. 5.7kcps/MBq system sensitivity with 24kcps/MBq effective sensitivity was obtained. The peak-NECR was ∼171kcps with the effective peak-NECR >650kcps@50kBq/mL. Scatter fraction was ∼30%, and the maximum trues was >900kcps. NEMA IQ demonstrated hot sphere contrast ranging from ∼62%±2%(10mm) to ∼88%±2%(22mm), cold sphere contrast of ∼86%±2%(28mm) and ∼89%±3%(37mm) and excellent uniformity. Monitoring 1-yr stability, it revealed ∼1% change in timing, ±0.4% change in energy resolution, and <10% variations in T&H. CQIE PET gave <3% SUV variances in axial. 60%–100% recovery coefficients across sphere sizes and contrast levels were achieved. Conclusion: Characteristics and stability of the next generation DPC PET detector system over an 1-yr time window was excellent and better than prior experiences. It demonstrated improved and robust system characteristics and performance in spatial resolution, sensitivity, timing and energy resolution, count rate and image quality. Michael Miller is an employee of Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

The hobbyist phenomenon in physical security.

Pro-Ams (professional amateurs) are groups of people who work on a problem as amateurs or unpaid persons in a given field at professional levels of competence. Astronomy is a good example of Pro-Am activity. At Galaxy Zoo, Pro-Ams evaluate data generated by professional observatories and are able to evaluate the millions of galaxies that have been observed but not classified, and report their findings at professional levels for fun. To allow the archiving of millions of galaxies that have been observed but not classified, the website has been engineered so that the public can view and classify galaxies even if they are not professional astronomers. In this endeavor, it has been found that amateurs can easily outperform automated vision systems. Today in the world of physical security, Pro-Ams are playing an ever-increasing role. Traditionally, locksmiths, corporations, and government organizations have been largely responsible for developing standards, uncovering vulnerabilities, and devising best security practices. Increasingly, however, nonprofit sporting organizations and clubs are doing this. They can be found all over the world, from Europe to the US and now South East Asia. Examples include TOOOL (The Open Organization of Lockpickers), the Longhorn Lockpicking Club, Sportsfreunde der Sperrtechnik - Deustcheland e.V., though there are many others. Members of these groups have been getting together weekly to discuss many elements of security, with some groups specializing in specific areas of security. When members are asked why they participate in these hobbyist groups, they usually reply (with gusto) that they do it for fun, and that they view defeating locks and other security devices as an interesting and entertaining puzzle. A lot of what happens at these clubs would not be possible if it weren't for 'Super Abundance', the ability to easily acquire (at little or no cost) the products, security tools, technologies, and intellectual resources traditionally limited to corporations, government organizations, or wealthy individuals. With this new access comes new discoveries. For example, hobbyist sport lockpicking groups discovered - and publicized - a number of new vulnerabilities between 2004 and 2009 that resulted in the majority of high-security lock manufacturers having to make changes and improvements to their products. A decade ago, amateur physical security discoveries were rare, at least those discussed publicly. In the interim, Internet sites such as lockpicking.org, lockpicking101.com and others have provided an online meeting place for people to trade tips, find friends with similar interests, and develop tools. The open, public discussion of software vulnerabilities, in contrast, has been going on for a long time. These two industries, physical security and software, have very different upgrade mechanisms. With software, a patch can typically be deployed quickly to fix a serious vulnerability, whereas a hardware fix for a physical security device or system can take upwards of months to implement in the field, especially if (as is often the case) hardware integrators are involved. Even when responding to publicly announced security vulnerabilities, manufacturers of physical security devices such as locks, intrusion detectors, or access control devices rarely view hobbyists as a positive resource. This is most unfortunate. In the field of software, it is common to speak of Open Source versus Closed Source. An Open Source software company may choose to distribute their software with a particular license, and give it away openly, with full details and all the lines of source code made available. Linux is a very popular example of this. A Close Source company, in contrast, chooses not to reveal its source code and will license its software products in a restrictive manor. Slowly, the idea of Open Source is now coming to the world of physical security. In the case of locks, it provides an alternative to the traditional Closed Source world of locksmiths. Now locks are physical objects, and can therefore be disassembled. As such, they have always been Open Source in a limited sense. Secrecy, in fact, is very difficult to maintain for a lock that is widely distributed. Having direct access to the lock design provides the hobbyist with a very open environment for finding security flaws, even if the lock manufacturer attempts to follow a Close Source model. It is clear that the field of physical security is going the digital route with companies such as Medeco, Mul-T-Lock, and Abloy manufacturing electromechanical locks. Various companies have already begun to add microcontrollers, cryptographic chip sets, solid-state sensors, and a number of other high-tech improvements to their product lineup in an effort to thwart people from defeating their security products.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for lepton-flavour-violating decays of the $Z$ boson into a $\tau$-lepton and a light lepton with the ATLAS detector

Lepton flavour violation in the charged lepton sector is an unambiguous signal of physics beyond the Standard Model. Searches for lepton flavour violation in decays of the Z Z boson with the ATLAS detector is reported, focusing on decays into an electron or muon and a hadronically decaying \tau τ -lepton, using pp p p collisions data with a centre-of-mass energy of 13 TeV. Upper limits on the branching ratios of lepton-flavor-violating decays are set at the 95% confidence level: \mathcal{B}(Z\to e\tau) < 5.8\times10^{-5} ℬ ( Z → e τ ) < 5.8 × 10 − 5 and \mathcal{B}(Z\to \mu\tau) < 2.4\times10^{-5} ℬ ( Z → μ τ ) < 2.4 × 10 − 5 . When combined with a previous ATLAS result based on pp p p collisions data with a centre-of-mass energy of 8 TeV, an upper limit of \mathcal{B}(Z\to \mu\tau) < 1.3\times10^{-5} ℬ ( Z → μ τ ) < 1.3 × 10 − 5 is obtained.

Chan, Wing Sheung↗

New opportunities at the next-generation neutrino experiments I: BSM neutrino physics and dark matter

The combination of the high intensity proton beam facilities and massive detectors for precision measurements of neutrino oscillation parameters including the charge-parity violating (CPV) phase will open the door to help make beyond the standard model (BSM) physics reachable even in low energy regimes in the accelerator-based experiments. Large-mass detectors with highly precise tracking and energy measurements, excellent timing resolution, and low energy thresholds will enable the searches for BSM phenomena from cosmogenic origin, as well. Therefore, it is also conceivable that BSM topics in the next-generation neutrino experiments could be the dominant physics topics in the foreseeable future, as the precision of the neutrino oscillation parameter and CPV measurements continue to improve. This paper reviews the current landscape of BSM theory in neutrino experiments in two selected areas of the BSM topics-dark matter and neutrino related BSM-and summarizes the current results from existing neutrino experiments to set benchmarks for both theory and experiment. This paper then provides a review of upcoming neutrino experiments throughout the next 10 to 15 year time scale and their capabilities to set the foundation for potential reach in BSM physics in the two aforementioned themes. An important outcome of this paper is to ensure theoretical and simulation tools exist to carry out studies of these new areas of physics, from the first day of the experiments, such as Deep Underground Neutrino Experiment in the U.S. and Hyper-Kamiokande Experiment in Japan.

dark sector↗

Characterization of spatially resolved high resolution x-ray spectrometers for high energy density physics and light source experiments

A high resolution 1D imaging x-ray spectrometer concept comprising a spherically bent crystal and a 2D pixelated detector is being optimized for diagnostics of small sources such as high energy density physics (HEDP) and synchrotron radiation or x-ray free electron laser experiments. This instrument is used on tokamak experiments for Doppler measurements of ion temperature and plasma flow velocity profiles. Laboratory measurements demonstrate a resolving power, E/ΔE of order 10 000 and spatial resolution better than 10 μm. Initial tests of the high resolution instrument on HEDP plasmas are being performed.

43 PARTICLE ACCELERATORS↗

Upgrading FLIR NanoRaider with the next Generation of CdZnTe Detectors. Goal - Integrate VFG detectors into FLIR R200. Advanced Virtual Grid ASIC (AVG-ASIC).

This document presents motivations, goals and the current status of this project; development (fabrication, performance) of position-sensitive virtual Frisch-grid detectors proposed for nanoRaider, an instrument commonly used by nuclear inspectors; ASIC developments for CZT detectors; and the electronics development for the detector prototype..

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity of Seismically Cued Antineutrino Detectors to Nuclear Explosions

Here, we evaluate the sensitivity of large gadolinium-doped water detectors to antineutrinos released by nuclear-fission explosions, using updated signal and background models and taking advantage of the capacity for seismic observations to provide an analysis trigger. Under certain realistic conditions, the antineutrino signature of a 250-kton pure-fission explosion could be identified several hundred kilometers away, in a detector about the size of the largest module currently proposed for a basic physics experiment. In principle, such an observation could provide rapid confirmation that the seismic signal coincided with a fission event, possibly useful for international monitoring of nuclear-weapon tests. We discuss the limited potential for seismically cued antineutrino observations to constrain fission yield, differentiate pure fission from fusion-enhanced weapon tests, indicate that the seismic evidence of an explosion had been intentionally masked, or verify the absence of explosive testing in a targeted area. We conclude that advances in seismic monitoring and neutrino physics have made the detection of explosion-derived antineutrinos more conceivable than previously asserted, but the size and cost of sufficiently sensitive detectors continue to limit applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the Muon Neutrino Magnetic Moment in the NOvA Near Detector

Measuring an enhanced neutrino magnetic moment would be a clear indication of physics beyond the Standard Model, shedding light on the correct beyond Standard Model theory or the potential Majorana nature of neutrinos. It would manifest in the NOvA near detector as an excess of neutrino-on-electron elastic scattering interactions at low electron recoil energies. Leveraging an intense and highly pure muon neutrino beam, along with a finely segmented liquid scintillator detector technology specifically designed for electromagnetic shower separation, enables NOvA to achieve a potentially world-leading sensitivity in probing the effective muon neutrino magnetic moment. This analysis, based on neutrino data collected between 2014 and 2021, corresponding to an exposure of $13.8\times10^{20}$ protons-on-target, yields a result consistent with the Standard Model-only hypothesis with a p-value of 0.31. An upper limit on the effective muon neutrino magnetic moment is set at $\mu_{\nu_\mu}<19.1\times 10^{-10}\mu_B$ at $90\%$ confidence level. Despite facing statistical limitations stemming from low cross section of the signal process, systematic uncertainties have a significant impact on this result. To address these challenges, the NOvA Test Beam experiment focuses on mitigating some of the largest systematic uncertainties within NOvA by investigating particle interactions and energy deposition in a small-scale replica NOvA detector. This thesis describes the calibration of the NOvA Test Beam detector, which is a crucial step in analysing the Test Beam data before they can be utilised to reduce NOvA systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A search for new physics in dijet mass and angular distributions in pp collisions at $\sqrt{s}$=7 TeV measured with the ATLAS detector

A search for new interactions and resonances produced in LHC proton-proton ( pp ) collisions at a centre-of-mass energy $\sqrt{s}$= 7 TeV has been performed with the ATLAS detector. Using a data set with an integrated luminosity of 36 pb -1 dijet mass and angular distributions have been measured up to dijet masses of ~3.5 TeV and found to be in good agreement with Standard Model predictions. This analysis sets limits at 95% C.L. on various models for new physics: an excited quark is excluded with mass between 0.60 and 2.64 TeV, an axigluon hypothesis is excluded for axigluon masses between 0.60 and 2.10 TeV and Randall-Meade quantum black holes are excluded in models with six extra space-time dimensions for quantum gravity scales between 0.75 and 3.67 TeV. Production cross section limits as a function of dijet mass are set using a simplified Gaussian signal model to facilitate comparisons with other hypotheses. In conclusion, analysis of the dijet angular distribution using a novel technique 18 simultaneously employing the dijet mass excludes quark contact interactions with a compositeness scale ${\Lambda}$ below 9.5 TeV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗