Radiation Dose and Subsequent Risk for Stomach Cancer in Long-term Survivors of Cervical Cancer

Purpose: To assess the dose–response relationship for stomach cancer after radiation therapy for cervical cancer. Methods and Materials: We conducted a nested, matched case–control study of 201 cases and 378 controls among 53,547 5-year survivors of cervical cancer diagnosed from 1943 to 1995, from 5 international, population-based cancer registries. We estimated individual radiation doses to the site of the stomach cancer for all cases and to corresponding sites for the matched controls (overall mean stomach tumor dose, 2.56 Gy, range 0.03-46.1 and after parallel opposed pelvic fields, 1.63 Gy, range 0.12-6.3). Results: More than 90% of women received radiation therapy, mostly with external beam therapy in combination with brachytherapy. Stomach cancer risk was nonsignificantly increased (odds ratio 1.27-2.28) for women receiving between 0.5 and 4.9 Gy to the stomach cancer site and significantly increased at doses ≥5 Gy (odds ratio 4.20, 95% confidence interval 1.41-13.4, P{sub trend}=.047) compared with nonirradiated women. A highly significant radiation dose–response relationship was evident when analyses were restricted to the 131 cases (251 controls) whose stomach cancer was located in the middle and lower portions of the stomach (P{sub trend}=.003), whereas there was no indication of increasing risk with increasing dose for 30 cases (57 controls) whose cancer was located in the upper stomach (P{sub trend}=.23). Conclusions: Our findings show for the first time a significant linear dose–response relationship for risk of stomach cancer in long-term survivors of cervical cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Comparison of 3-Dimensional Planning Techniques Using an Intravaginal Multichannel Balloon Applicator for High-Dose-Rate Gynecologic Brachytherapy

Purpose: To study the dosimetric differences of various channel combinations of the Capri vaginal applicator. Methods and Materials: The Capri consists of a single central channel (R1), an inner array of 6 channels (R2), and an outer array of 6 channels (R3). Three-dimensional plans were simulated for 6 channel arrangements (R1, R2, R12, R13, R23, and R123). Treatment plans were optimized to the applicator surface or 5-mm depth while minimizing dose to organs at risk (OARs: bladder, rectum, sigmoid, and urethra). The clinical target volume (CTV) was defined as a 5-mm circumferential shell extending 4 cm in length around the applicator. Clinical target volume coverage (D{sub mean}, D{sub 90}, V{sub 100}, and V{sub 150}) and OAR doses (D{sub 0.1} {sub cm{sup 3}}, D{sub 1} {sub cm{sup 3}}, D{sub 2} {sub cm{sup 3}}, and D{sub mean}) were compared. A comparison between the Capri (R123) and a conventional single-channel applicator was also done. Statistical significance (P value <.05) was evaluated with a 2-tailed t test. Results: When prescribing to 5-mm depth, CTV coverage using all 13 channels (R123) versus a single channel (R1) was similar; however, when prescribing to the surface there were differences (P<.0001) in all CTV metrics except for the V{sub 150}. The R1 plans had higher doses to all OARs compared with R123 plans (P<.007). Doses to OARs were not significantly different between R23 and R123 plans (P=.05-.95), and CTV coverage differences were on the order of 1%. Capri R123 plans provided slightly lower CTV D{sub 90} and D{sub mean} but equivalent OAR doses with smaller standard deviations compared with conventional cylinder plans for both prescriptions. Conclusions: The Capri multichannel applicator provides equivalent target coverage at 5-mm depth, with significantly reduced dose to OARs relative to using a single channel. Optimal plans can be achieved using R12 (lowest V{sub 150}) or R123 or R23 (lowest OAR doses)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose and Extended-Field Intensity Modulated Radiation Therapy for Early-Stage NK/T-Cell Lymphoma of Waldeyer's Ring: Dosimetric Analysis and Clinical Outcome

Purpose: To assess the dosimetric benefit, treatment outcome, and toxicity of high-dose and extended-field intensity modulated radiation therapy (IMRT) in patients with early-stage NK/T-cell lymphoma of Waldeyer's ring (WR-NKTCL). Methods and Materials: Thirty patients with early-stage WR-NKTCL who received extended-field IMRT were retrospectively reviewed. The prescribed dose was 50 Gy to the primary involved regions and positive cervical lymph nodes (planning target volume requiring radical irradiation [PTV{sub 50}]) and 40 Gy to the negative cervical nodes (PTV{sub 40}). Dosimetric parameters for the target volume and critical normal structures were evaluated. Locoregional control (LRC), overall survival (OS), and progression-free survival (PFS) were calculated using the Kaplan-Meier method. Results: The median mean doses to the PTV{sub 50} and PTV{sub 40} were 53.2 Gy and 43.0 Gy, respectively. Only 1.4% of the PTV{sub 50} and 0.9% of the PTV{sub 40} received less than 95% of the prescribed dose, indicating excellent target coverage. The average mean doses to the left and right parotid glands were 27.7 and 28.4 Gy, respectively. The 2-year OS, PFS, and LRC rates were 71.2%, 57.4%, and 87.8%. Most acute toxicities were grade 1 to 2, except for grade ≥3 dysphagia and mucositis. The most common late toxicity was grade 1-2 xerostomia, and no patient developed any ≥grade 3 late toxicities. A correlation between the mean dose to the parotid glands and the degree of late xerostomia was observed. Conclusions: IMRT achieves excellent target coverage and dose conformity, as well as favorable survival and locoregional control rates with acceptable toxicities in patients with WR-NKTCL.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is Intermediate Radiation Dose Escalation With Concurrent Chemotherapy for Stage III Non–Small-Cell Lung Cancer Beneficial? A Multi-Institutional Propensity Score Matched Analysis

Purpose: The clinical benefits and risks of dose escalation (DE) for stage III non–small-cell lung cancer (NSCLC) remain uncertain despite the results from Radiation Therapy Oncology Group (RTOG) protocol 0617. There is significant heterogeneity of practice, with many clinicians prescribing intermediate dose levels between the 0617 study arms of 60 and 74 Gy. This study investigated whether this strategy is associated with any survival benefits/risks by analyzing a large multi-institutional database. Methods and Materials: An individual patient database of stage III NSCLC patients treated with radical intent concurrent chemoradiation therapy was created (13 institutions, n=1274 patients). Patients were divided into 2 groups based on tumor Biological Effective Dose at 10 Gy (BED 10): those receiving standard dose (SD; n=552), consisting of 72Gy ≤ BED 10 ≤ 76.8 Gy (eg 60-64 Gy/30-32 fractions [fr]), and those receiving intermediate dose (ID; n=497), consisting of 76.8Gy < BED 10 < 100.8 Gy (eg >64 Gy/32 fr and <74 Gy/37 fr), with lower-dose patients (n=225) excluded from consideration. Patients were then matched using propensity scores, leading to 2 matched groups of 196 patients. Outcomes were compared using various statistics including interquartile range (IQR), Kaplan-Meier curves, and adjusted Cox regression analysis. Results: Matched groups were found to be balanced except for N stage (more N3 disease in SD), median treatment year (SD in 2003; ID in 2007), platinum and taxane chemotherapy (SD in 28%; ID in 39%), and median follow-up (SD were 89 months; ID were 40 months). Median dose fractionation was 60 Gy/30 fr in SD (BED 10 IQR: 72.0-75.5 Gy) and 66 Gy/33 fr (BED 10 IQR: 78.6-79.2 Gy) in ID. Survival curves for SD and ID matched cohorts were statistically similar (P=.27); however, a nonstatistically significant trend toward better survival for ID was observed after 15 months (median survival SD: 19.3 months; ID: 21.0 months). There was an increase in grades III to V lung toxicity associated with ID (13.0% vs 4.9%, respectively). Conclusions: No significant overall survival benefits were found with intermediate DE; however, more grade III or greater lung toxicity was observed. The separation of survival curves after 15 months of follow-up suggests that a small overall survival improvement associated with intermediate DE cannot be excluded.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Increasing Radiation Therapy Dose Is Associated With Improved Survival in Patients Undergoing Stereotactic Body Radiation Therapy for Stage I Non–Small-Cell Lung Cancer

Purpose: To determine the comparative effectiveness of different stereotactic body radiation therapy (SBRT) dosing regimens for early-stage non–small-cell lung cancer, using a large national database, focusing on the relative impact of dose as a function of tumor stage. Methods and Materials: The study included patients in the National Cancer Database from 2003 to 2006 with T1-T2N0M0 inoperable lung cancer (n=498). The biologically effective dose (BED) was calculated according to the linear quadratic formula using an α/β ratio of 10. High versus lower-dose (HD vs LD) SBRT was defined as a calculated BED above or below 150 Gy. Overall survival was estimated using Kaplan-Meier methods and Cox proportional hazard regression. Results: The 5 most common dose fractionation schemes (percentage of cohort) used were 20 Gy × 3 (34%), 12 Gy × 4 (16%), 18 Gy × 3 (10%), 15 Gy × 3 (10%), and 16 Gy × 3 (4%). The median calculated BED was 150 Gy (interquartile range 106-166 Gy). The 3-year overall survival (OS) for patients who received HD versus LD was 55% versus 46% (log–rank P=.03). On subset analysis of the T1 cohort there was no association between calculated BED and 3-year OS (61% vs 60% with HD vs LD, P=.9). Among the T2 cohort, patients receiving HD experienced superior 3-year OS (37% vs 24%, P=.01). On multivariable analysis, factors independently prognostic for mortality were female gender (hazard ratio [HR] 0.76, P=.01), T2 tumor (HR 1.99, P=.0001), and HD (HR 0.68, P=.001). Conclusions: This comparative effectiveness analysis of SBRT dose for patients with stage I non–small-cell lung cancer suggests that higher doses (>150 Gy BED) are associated with a significant survival benefit in patients with T2 tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing Dose Uncertainty for Spot-Scanning Proton Beam Therapy of Moving Tumors by Optimizing the Spot Delivery Sequence

Purpose: To develop and validate a novel delivery strategy for reducing the respiratory motion–induced dose uncertainty of spot-scanning proton therapy. Methods and Materials: The spot delivery sequence was optimized to reduce dose uncertainty. The effectiveness of the delivery sequence optimization was evaluated using measurements and patient simulation. One hundred ninety-one 2-dimensional measurements using different delivery sequences of a single-layer uniform pattern were obtained with a detector array on a 1-dimensional moving platform. Intensity modulated proton therapy plans were generated for 10 lung cancer patients, and dose uncertainties for different delivery sequences were evaluated by simulation. Results: Without delivery sequence optimization, the maximum absolute dose error can be up to 97.2% in a single measurement, whereas the optimized delivery sequence results in a maximum absolute dose error of ≤11.8%. In patient simulation, the optimized delivery sequence reduces the mean of fractional maximum absolute dose error compared with the regular delivery sequence by 3.3% to 10.6% (32.5-68.0% relative reduction) for different patients. Conclusions: Optimizing the delivery sequence can reduce dose uncertainty due to respiratory motion in spot-scanning proton therapy, assuming the 4-dimensional CT is a true representation of the patients' breathing patterns.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Dependent Cortical Thinning After Partial Brain Irradiation in High-Grade Glioma

Purpose: Radiation-induced cognitive deficits may be mediated by tissue damage to cortical regions. Volumetric changes in cortex can be reliably measured using high-resolution magnetic resonance imaging (MRI). We used these methods to study the association between radiation therapy (RT) dose and change in cortical thickness in high-grade glioma (HGG) patients. Methods and Materials: We performed a voxel-wise analysis of MRI from 15 HGG patients who underwent fractionated partial brain RT. Three-dimensional MRI was acquired pre- and 1 year post RT. Cortex was parceled with well-validated segmentation software. Surgical cavities were censored. Each cortical voxel was assigned a change in cortical thickness between time points, RT dose value, and neuroanatomic label by lobe. Effects of dose, neuroanatomic location, age, and chemotherapy on cortical thickness were tested using linear mixed effects (LME) modeling. Results: Cortical atrophy was seen after 1 year post RT with greater effects at higher doses. Estimates from LME modeling showed that cortical thickness decreased by −0.0033 mm (P<.001) for every 1-Gy increase in RT dose. Temporal and limbic cortex exhibited the largest changes in cortical thickness per Gy compared to that in other regions (P<.001). Age and chemotherapy were not significantly associated with change in cortical thickness. Conclusions: We found dose-dependent thinning of the cerebral cortex, with varying neuroanatomical regional sensitivity, 1 year after fractionated partial brain RT. The magnitude of thinning parallels 1-year atrophy rates seen in neurodegenerative diseases and may contribute to cognitive decline following high-dose RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigating the Implications of a Variable RBE on Proton Dose Fractionation Across a Clinical Pencil Beam Scanned Spread-Out Bragg Peak

Purpose: To investigate the clinical implications of a variable relative biological effectiveness (RBE) on proton dose fractionation. Using acute exposures, the current clinical adoption of a generic, constant cell killing RBE has been shown to underestimate the effect of the sharp increase in linear energy transfer (LET) in the distal regions of the spread-out Bragg peak (SOBP). However, experimental data for the impact of dose fractionation in such scenarios are still limited. Methods and Materials: Human fibroblasts (AG01522) at 4 key depth positions on a clinical SOBP of maximum energy 219.65 MeV were subjected to various fractionation regimens with an interfraction period of 24 hours at Proton Therapy Center in Prague, Czech Republic. Cell killing RBE variations were measured using standard clonogenic assays and were further validated using Monte Carlo simulations and parameterized using a linear quadratic formalism. Results: Significant variations in the cell killing RBE for fractionated exposures along the proton dose profile were observed. RBE increased sharply toward the distal position, corresponding to a reduction in cell sparing effectiveness of fractionated proton exposures at higher LET. The effect was more pronounced at smaller doses per fraction. Experimental survival fractions were adequately predicted using a linear quadratic formalism assuming full repair between fractions. Data were also used to validate a parameterized variable RBE model based on linear α parameter response with LET that showed considerable deviations from clinically predicted isoeffective fractionation regimens. Conclusions: The RBE-weighted absorbed dose calculated using the clinically adopted generic RBE of 1.1 significantly underestimates the biological effective dose from variable RBE, particularly in fractionation regimens with low doses per fraction. Coupled with an increase in effective range in fractionated exposures, our study provides an RBE dataset that can be used by the modeling community for the optimization of fractionated proton therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Implementation of a Model-Based In Vivo Dose Verification System for Stereotactic Body Radiation Therapy–Volumetric Modulated Arc Therapy Treatments Using the Electronic Portal Imaging Device

Purpose: To report findings from an in vivo dosimetry program implemented for all stereotactic body radiation therapy patients over a 31-month period and discuss the value and challenges of utilizing in vivo electronic portal imaging device (EPID) dosimetry clinically. Methods and Materials: From December 2013 to July 2016, 117 stereotactic body radiation therapy–volumetric modulated arc therapy patients (100 lung, 15 spine, and 2 liver) underwent 602 EPID-based in vivo dose verification events. A developed model-based dose reconstruction algorithm calculates the 3-dimensional dose distribution to the patient by back-projecting the primary fluence measured by the EPID during treatment. The EPID frame-averaging was optimized in June 2015. For each treatment, a 3%/3-mm γ comparison between our EPID-derived dose and the Eclipse AcurosXB–predicted dose to the planning target volume (PTV) and the ≥20% isodose volume were performed. Alert levels were defined as γ pass rates <85% (lung and liver) and <80% (spine). Investigations were carried out for all fractions exceeding the alert level and were classified as follows: EPID-related, algorithmic, patient setup, anatomic change, or unknown/unidentified errors. Results: The percentages of fractions exceeding the alert levels were 22.6% for lung before frame-average optimization and 8.0% for lung, 20.0% for spine, and 10.0% for liver after frame-average optimization. Overall, mean (± standard deviation) planning target volume γ pass rates were 90.7% ± 9.2%, 87.0% ± 9.3%, and 91.2% ± 3.4% for the lung, spine, and liver patients, respectively. Conclusions: Results from the clinical implementation of our model-based in vivo dose verification method using on-treatment EPID images is reported. The method is demonstrated to be valuable for routine clinical use for verifying delivered dose as well as for detecting errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatial and temporal prediction of radiation dose rates near Fukushima Daiichi Nuclear Power Plant

In this paper, we have developed a methodology to estimate the spatiotemporal distribution of radiation air dose rates around the Fukushima Daiichi Nuclear Power Plant (FDNPP). In our exploratory data analysis, we found that (1) the temporal evolution of dose rates is composed of a log-linear decay trend and fluctuations of air dose rates that are spatially correlated among adjacent monitoring posts; and (2) the slope of the log-linear environmental decay trend can be represented as a function of the apparent initial dose rates, coordinate position, land-use type, and soil type. From these observations, we first estimated the log-linear decay trend at each location based on these predictors, using the random forest method. We then developed a modified Kalman filter coupled with a Gaussian process model to estimate the dose-rate time series at a given location and time. We applied this method to the Fukushima evacuation zone (as of March 2017), which included 17 monitoring post locations (with monitoring datasets collected between 2014 and 2018) and generated a time series of dose-rate maps. Our results show that this approach allows us to produce accurate spatial and temporal predictions of radiation dose-rate maps using limited spatiotemporal measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cone Beam Computed Tomography: The Challenges and Strategies in Its Application for Dose Accumulation

Online image guidance using cone beam computed tomography (CBCT) has greatly improved the geometric precision of radiotherapy. Changes in anatomy are common during a course of fractionated treatment, resulting in dose deviation from the planned distribution. There is increased interest in performing dose accumulation to compute the actual delivered dose and to adapt the treatment when necessary. This can be achieved by delineating the volume of interest and by generating “dose of the day” through dose computation on the CBCT. However, the image quality and the accuracy of the CT number of CBCT are deemed to be inferior to fan beam CT, which increases the uncertainty associated in this process. A review of literature was conducted to assess the reliability of and to examine strategies for overcoming the challenges in using CBCT for volume delineation and dose computation. The review demonstrates that the uncertainty varies across body sites, and different strategies have been recommended to generate comparable results to images from CT simulators. This facilitates a better understanding of the potential and the limitation of using CBCT for dose accumulation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of structural properties of pristine and gamma irradiated single-wall carbon nanotubes: Effects of medium and irradiation dose

A systematic study of the gamma irradiation effects on single wall carbon nanotube (SWCNT) structure was conducted. Nanotubes were exposed to different doses of gamma irradiation in three media. Irradiation was carried out in air, water and aqueous ammonia. Thermogravimetric analysis (TGA), Fourier transform infrared spectroscopy (FTIR), elemental analysis (EA) and Raman spectroscopy confirmed the changes in the SWCNT structure. TGA measurements showed the highest percentage of introduced groups for the SWCNTs irradiated with 100 kGy. FTIR spectroscopy provided evidence for the attachment of hydroxyl, carboxyl and nitrile functional groups to the SWCNT sidewalls. Those groups were confirmed by EA. All irradiated SWCNTs had hydroxyl and carboxyl groups irrelevant to media used for irradiation, but nitrile functional groups were only identified in SWCNTs irradiated in aqueous ammonia. Raman spectroscopy indicated that the degree of disorder in the carbon nanotube structure correlates with the irradiation dose. For the nanotubes irradiated with the dose of 100 kGy, the Raman I{sub D}/I{sub G} ratio was three times higher than for the pristine ones. Atomic force microscopy showed a 50% decrease in nanotube length at a radiation dose of 100 kGy. Scanning and transmission electron microscopies showed significant changes in the morphology and structure of gamma irradiated SWCNTs. - Highlights: Black-Right-Pointing-Pointer Gamma irradiation causes SWCNT covalent functionalization. Black-Right-Pointing-Pointer Type of covalently attached groups to SWCNT surface depends on irradiation medium. Black-Right-Pointing-Pointer The SWCNT shortening level increases with applied irradiation dose. Black-Right-Pointing-Pointer The average length of carbon nanotubes decreased by 50% at the highest dose. Black-Right-Pointing-Pointer The diameter of SWCNT bundles becomes small as irradiation dose rises.

36 MATERIALS SCIENCE↗

Characteristics of Movement-Induced Dose Reduction in Target Volume: A Comparison Between Photon and Proton Beam Treatment

We compared the main characteristics of movement-induced dose reduction during photon and proton beam treatment, based on an analysis of dose-volume histograms. To simulate target movement, a target contour was delineated in a scanned phantom and displaced by 3 to 20 mm. Although the dose reductions to the target in the 2 treatment systems were similar for transverse (perpendicular to beam direction) target motion, they were completely different for longitudinal (parallel to beam direction) target motion. While both modalities showed a relationship between the degree of target shift and the reduction in dose coverage, dose reduction showed a strong directional dependence in proton beam treatment. Clinical simulation of target movement for a prostate cancer patient showed that, although coverage and conformity indices for a 6-mm lateral movement of the prostate were reduced by 9% and 16%, respectively, for proton beam treatment, they were reduced by only 1% and 7%, respectively, for photon treatment. This difference was greater for a 15-mm target movement in the lateral direction, which lowered the coverage and conformity indices by 34% and 54%, respectively, for proton beam treatment, but changed little during photon treatment. In addition, we found that the equivalent uniform dose (EUD) and homogeneity index show similar characteristics during target movement. These results suggest that movement-induced dose reduction differs significantly between photon and proton beam treatment. Attention should be paid to the target margin in proton beam treatment due to the distinct characteristics of heavy ion beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Effect of Significant Tumor Reduction on the Dose Distribution in Intensity Modulated Radiation Therapy for Head-And-Neck Cancer: A Case Study

We present a unique case in which a patient with significant tissue loss was monitored for dosimetric changes using weekly cone beam computed tomography (CBCT) scans. A previously treated nasopharynx patient presented with a large, exophytic, recurrent left neck mass. The patient underwent re-irradiation to 70 Gy using intensity modulated radiation therapy (IMRT) with shielding blocks over the spinal cord and brain stem. Weekly CBCT scans were acquired during treatment. Target contours and treatment fields were then transferred from the original treatment planning computed tomography (CT) to the CBCT scans and dose calculations were performed on all CBCT scans and compared to the planning doses. In addition, a 'research' treatment plan was created that assumed the patient had not been previously treated, and the above analysis was repeated. Finally, to remove the effects of setup error, the outer contours of 2 CBCT scans with significant tumor reductions were transferred to the planning scan and dose in the planning scan was recalculated. Planning treatment volume (PTV) decreased 45% during treatment. Spinal cord D05 differed from the planned value by 3.5 {+-} 9.8% (average + standard deviation). Mean dose to the oral cavity and D05 of the mandible differed from the planned value by 0.9 {+-} 2.1% and 0.6 {+-} 1.5%, respectively. Results for the research plan were comparable. Target coverage did not change appreciably (-0.2 {+-} 2.5%). When the planning scan was recalculated with the reduced outer contour from the CBCT, spinal cord D05 decreased slightly due to the reduction in scattered dose. Weekly imaging provided us the unique opportunity to use different methods to examine the dosimetric effects of an unusually large loss of tissue. We did not see that tissue loss alone resulted in a significant effect on the dose delivered to the spinal cord for this case, as most fluctuation was due to setup error. In the IGRT era, delivered dose distributions can be more readily determined during treatment, and this information can be useful in deciding whether replanning is necessary.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dependences of mucosal dose on photon beams in head-and-neck intensity-modulated radiation therapy: a Monte Carlo study

Dependences of mucosal dose in the oral or nasal cavity on the beam energy, beam angle, multibeam configuration, and mucosal thickness were studied for small photon fields using Monte Carlo simulations (EGSnrc-based code), which were validated by measurements. Cylindrical mucosa phantoms (mucosal thickness = 1, 2, and 3 mm) with and without the bone and air inhomogeneities were irradiated by the 6- and 18-MV photon beams (field size = 1 Multiplication-Sign 1 cm{sup 2}) with gantry angles equal to 0 Degree-Sign , 90 Degree-Sign , and 180 Degree-Sign , and multibeam configurations using 2, 4, and 8 photon beams in different orientations around the phantom. Doses along the central beam axis in the mucosal tissue were calculated. The mucosal surface doses were found to decrease slightly (1% for the 6-MV photon beam and 3% for the 18-MV beam) with an increase of mucosal thickness from 1-3 mm, when the beam angle is 0 Degree-Sign . The variation of mucosal surface dose with its thickness became insignificant when the beam angle was changed to 180 Degree-Sign , but the dose at the bone-mucosa interface was found to increase (28% for the 6-MV photon beam and 20% for the 18-MV beam) with the mucosal thickness. For different multibeam configurations, the dependence of mucosal dose on its thickness became insignificant when the number of photon beams around the mucosal tissue was increased. The mucosal dose with bone was varied with the beam energy, beam angle, multibeam configuration and mucosal thickness for a small segmental photon field. These dosimetric variations are important to consider improving the treatment strategy, so the mucosal complications in head-and-neck intensity-modulated radiation therapy can be minimized.

61 RADIATION PROTECTION AND DOSIMETRY↗

Circumferential or sectored beam arrangements for stereotactic body radiation therapy (SBRT) of primary lung tumors: Effect on target and normal-structure dose-volume metrics

To compare 2 beam arrangements, sectored (beam entry over ipsilateral hemithorax) vs circumferential (beam entry over both ipsilateral and contralateral lungs), for static-gantry intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) delivery techniques with respect to target and organs-at-risk (OAR) dose-volume metrics, as well as treatment delivery efficiency. Data from 60 consecutive patients treated using stereotactic body radiation therapy (SBRT) for primary non–small-cell lung cancer (NSCLC) formed the basis of this study. Four treatment plans were generated per data set: IMRT/VMAT plans using sectored (-s) and circumferential (-c) configurations. The prescribed dose (PD) was 60 Gy in 5 fractions to 95% of the planning target volume (PTV) (maximum PTV dose ∼ 150% PD) for a 6-MV photon beam. Plan conformality, R{sub 50} (ratio of volume circumscribed by the 50% isodose line and the PTV), and D{sub 2} {sub cm} (D{sub max} at a distance ≥2 cm beyond the PTV) were evaluated. For lungs, mean doses (mean lung dose [MLD]) and percent V{sub 30}/V{sub 20}/V{sub 10}/V{sub 5} Gy were assessed. Spinal cord and esophagus D{sub max} and D{sub 5}/D{sub 50} were computed. Chest wall (CW) D{sub max} and absolute V{sub 30}/V{sub 20}/V{sub 10}/V{sub 5} {sub Gy} were reported. Sectored SBRT planning resulted in significant decrease in contralateral MLD and V{sub 10}/V{sub 5} {sub Gy}, as well as contralateral CW D{sub max} and V{sub 10}/V{sub 5} {sub Gy} (all p < 0.001). Nominal reductions of D{sub max} and D{sub 5}/D{sub 50} for the spinal cord with sectored planning did not reach statistical significance for static-gantry IMRT, although VMAT metrics did show a statistically significant decrease (all p < 0.001). The respective measures for esophageal doses were significantly lower with sectored planning (p < 0.001). Despite comparable dose conformality, irrespective of planning configuration, R{sub 50} significantly improved with IMRT-s/VMAT-c (p < 0.001/p = 0.008), whereas D{sub 2} {sub cm} significantly improved with VMAT-c (p < 0.001). Plan delivery efficiency improved with sectored technique (p < 0.001); mean monitor unit (MU)/cGy of PD decreased from 5.8 ± 1.9 vs 5.3 ± 1.7 (IMRT) and 2.7 ± 0.4 vs 2.4 ± 0.3 (VMAT). The sectored configuration achieves unambiguous dosimetric advantages over circumferential arrangement in terms of esophageal, contralateral CW, and contralateral lung sparing, in addition to being more efficient at delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluating proton stereotactic body radiotherapy to reduce chest wall dose in the treatment of lung cancer

Stereotactic body radiotherapy (SBRT) can produce excellent local control of several types of solid tumor; however, toxicity to nearby critical structures is a concern. We found previously that in SBRT for lung cancer, the chest wall (CW) volume receiving 20, 30, or 40 Gy (V{sub 20}, V{sub 30}, or V{sub 40}) was linked with the development of neuropathy. Here we sought to determine whether the dosimetric advantages of protons could produce lower CW doses than traditional photon-based SBRT. We searched an institutional database to identify patients treated with photon SBRT for lung cancer with tumors within < 2.5 cm of the CW. We found 260 cases; of these, chronic grade ≥ 2 CW pain was identified in 23 patients. We then selected 10 representative patients from this group and generated proton SBRT treatment plans, using the identical dose of 50 Gy in 4 fractions, and assessed potential differences in CW dose between the 2 plans. The proton SBRT plans reduced the CW doses at all dose levels measured. The median CW V{sub 20} was 364.0 cm{sup 3} and 160.0 cm{sup 3} (p < 0.0001), V{sub 30} was 144.6 cm{sup 3}vs 77.0 cm{sup 3} (p = 0.0012), V{sub 35} was 93.9 cm{sup 3}vs 57.9 cm{sup 3} (p = 0.005), V{sub 40} was 66.5 cm{sup 3}vs 45.4 cm{sup 3} (p = 0.0112), and mean lung dose was 5.9 Gy vs 3.8 Gy (p = 0.0001) for photons and protons, respectively. Coverage of the planning target volume (PTV) was comparable between the 2 sets of plans (96.4% for photons and 97% for protons). From a dosimetric standpoint, proton SBRT can achieve the same coverage of the PTV while significantly reducing the dose to the CW and lung relative to photon SBRT and therefore may be beneficial for the treatment of lesions closer to critical structures.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dynamics of the vaginal wall dose in HDR interstitial brachytherapy for gynecological cancer: Systematic analysis of phantom vs patient case

This study aimed to investigate the dynamics of the vaginal wall dose for interstitial brachytherapy (ISBT). A patient undergoing ISBT was selected as the patient case. The phantom case was generated to simulate the patient case in all regards with the exception of parallel needle positions. The vaginal wall was contoured as a 0.5-cm expansion around the vaginal surface of the obturator. The prescribed ISBT dose was 20 Gy in 4 fractions. Six treatment plans were generated by modifying relative dwell times and needle positions (DTNP). The volume of the vaginal wall receiving > 150% of prescription dose (V{sub > 150%}) and D{sub 2cc} of the vaginal wall were compared among plans. The V{sub > 150%} was much larger in the patient case (49.3%) due to unparallel needles compared with the phantom case (14.3%) without modification (plan 1). Among the 6 plans, reduced dwell time (plan 3) and no dwell time (plans 5 and 6) on the vaginal surface needles had the lowest vaginal wall doses with the use of a central obturator needle in both cases. In comparison of patient case plans 1, 3, 5, and 6, V{sub 150%} was 49.2%, 19.0%, 21.3%, and 28.7%, respectively, and D{sub 2cc} was 41.15 Gy, 33.10 Gy, 36.51 Gy, and 34.37 Gy, respectively, which was limited around each loaded needle. Modification of DTNP is able to reduce the vaginal wall volume exceeding 150% of the prescription dose in the patient case. Understanding these dynamics of the vaginal wall dose will improve dose optimization of ISBT and may reduce vaginal morbidities.