Search NASA⌕ Search

SEARCH · Search NASA

Results for “FASTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Fast and slow crystal growth kinetics in glass-forming melts

Published values of crystal growth rates are compared for supercooled glass-forming liquids undergoing congruent freezing at a planar crystal-liquid interface. For the purposes of comparison pure metals are considered to be glass-forming systems, using data from molecular-dynamics simulations. For each system, the growth rate has a maximum value U{sub max} at a temperature T{sub max} that lies between the glass-transition temperature T{sub g} and the melting temperature T{sub m}. A classification is suggested, based on the lability (specifically, the propensity for fast crystallization), of the liquid. High-lability systems show “fast” growth characterized by a high U{sub max}, a low T{sub max} / T{sub m}, and a very broad peak in U vs. T / T{sub m}. In contrast, systems showing “slow” growth have a low U{sub max}, a high T{sub max} / T{sub m}, and a sharp peak in U vs. T / T{sub m}. Despite the difference of more than 11 orders of magnitude in U{sub max} seen in pure metals and in silica, the range of glass-forming systems surveyed fit into a common pattern in which the lability increases with lower reduced glass-transition temperature (T{sub g} / T{sub m}) and higher fragility of the liquid. A single parameter, a linear combination of T{sub g} / T{sub m} and fragility, can show a good correlation with U{sub max}. For all the systems, growth at U{sub max} is coupled to the atomic/molecular mobility in the liquid. It is found that, across the diversity of glass-forming systems, T{sub max} / T{sub g} = 1.48 ± 0.15.

36 MATERIALS SCIENCE↗

Ion-induced gamma-ray detection of fast ions escaping from fusion plasmas

A 12 × 12 pixel detector has been developed and used in a laboratory experiment for lost fast-ion diagnostics. With gamma rays in the MeV range originating from nuclear reactions {sup 9}Be(α, nγ){sup 12}C, {sup 9}Be(d, nγ){sup 12}C, and {sup 12}C(d, pγ){sup 13}C, a high purity germanium (HPGe) detector measured a fine-energy-resolved spectrum of gamma rays. The HPGe detector enables the survey of background-gamma rays and Doppler-shifted photo peak shapes. In the experiments, the pixel detector produces a gamma-ray image reconstructed from the energy spectrum obtained from total photon counts of irradiation passing through the detector's lead collimator. From gamma-ray image, diagnostics are able to produce an analysis of the fast ion loss onto the first wall in principle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual design of a fast-ion D-alpha diagnostic on experimental advanced superconducting tokamak

To investigate the fast ion behavior, a fast ion D-alpha (FIDA) diagnostic system has been planned and is presently under development on Experimental Advanced Superconducting Tokamak. The greatest challenges for the design of a FIDA diagnostic are its extremely low intensity levels, which are usually significantly below the continuum radiation level and several orders of magnitude below the bulk-ion thermal charge-exchange feature. Moreover, an overlaying Motional Stark Effect (MSE) feature in exactly the same wavelength range can interfere. The simulation of spectra code is used here to guide the design and evaluate the diagnostic performance. The details for the parameters of design and hardware are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wide dynamic range neutron flux monitor having fast time response for the Large Helical Device

A fast time response, wide dynamic range neutron flux monitor has been developed toward the LHD deuterium operation by using leading-edge signal processing technologies providing maximum counting rate up to ∼5 × 10{sup 9} counts/s. Because a maximum total neutron emission rate over 1 × 10{sup 16} n/s is predicted in neutral beam-heated LHD plasmas, fast response and wide dynamic range capabilities of the system are essential. Preliminary tests have demonstrated successful performance as a wide dynamic range monitor along the design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cost-effective and highly sensitive cholesterol microsensors with fast response based on the enzyme-induced conductivity change of polyaniline

In this study, a cost-effective and highly sensitive cholesterol microsensor, which is consisted of cholesterol oxidase (ChOx), horseradish peroxidase (HRP), and polyaniline (PANI), was developed based on the enzyme-induced conductivity change of PANI with fast response. Hydrogen peroxide is produced via the reaction between cholesterol and ChOx, which was immobilized in a dialysis membrane. The produced hydrogen peroxide can oxidize HRP, which can be reduced by oxidizing PANI, thus resulting in decreased conductivity of the polyaniline thin film. The reduced HRP can be oxidized again by hydrogen peroxide and the cycle of the oxidation/reduction continues until all hydrogen peroxide are reacted, leading to the high sensitivity of the sensor due to the signal contributed from all hydrogen peroxide molecules. Cholesterol was detected near the physiological concentrations ranging from 100 mg/dl to 400 mg/dl with the cholesterol microsensors. The results show linear relation between cholesterol concentration and the conductivity change of the PANI. The microsensor showed no response to cholesterol when the PANI was standalone without cholesterol oxidase immobilized, indicating that the enzymatic reaction is required for cholesterol detection. The simple process of the sensor fabrication allows the sensor to be cost-effective and disposable usage. This electronic cholesterol microsensor is promising for point-of-care health monitoring in cholesterol level with low cost and fast response.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Adaptive AFM scan speed control for high aspect ratio fast structure tracking

Improved imaging rates in Atomic Force Microscopes (AFM) are of high interest for disciplines such as life sciences and failure analysis of semiconductor wafers, where the sample topology shows high aspect ratios. Also, fast imaging is necessary to cover a large surface under investigation in reasonable times. Since AFMs are composed of mechanical components, they are associated with comparably low resonance frequencies that undermine the effort to increase the acquisition rates. In particular, high and steep structures are difficult to follow, which causes the cantilever to temporarily loose contact to or crash into the sample. Here, we report on a novel approach that does not affect the scanner dynamics, but adapts the lateral scanning speed of the scanner. The controller monitors the control error signal and, only when necessary, decreases the scan speed to allow the z-piezo more time to react to changes in the sample's topography. In this case, the overall imaging rate can be significantly increased, because a general scan speed trade-off decision is not needed and smooth areas are scanned fast. In contrast to methods trying to increase the z-piezo bandwidth, our method is a comparably simple approach that can be easily adapted to standard systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast, high-fidelity, all-optical and dynamically-controlled polarization gate using room-temperature atomic vapor

We demonstrate a fast, all-optical polarization gate in a room-temperature atomic medium. Using a Polarization-Selective-Kerr-Phase-Shift (PSKPS) technique, we selectively write a π phase shift to one circularly-polarized component of a linearly-polarized input signal field. The output signal field maintains its original strength but acquires a 90° linear polarization rotation, demonstrating fast, high-fidelity, dynamically-controlled polarization gate operation. The intensity of the polarization-switching field used in this PKSPK-based polarization gate operation is only 2 mW/cm{sup 2}, which would be equivalent to 0.5 nW of light power (λ = 800 nm) confined in a typical commercial photonic hollow-core fiber. This development opens a realm of possibilities for potential future extremely low light level telecommunication and information processing systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Collimated fast electron beam generation in critical density plasma

Significantly collimated fast electron beam with a divergence angle 10° (FWHM) is observed when an ultra-intense laser pulse (I = 10{sup 14 }W/cm{sup 2}, 300 fs) irradiates a uniform critical density plasma. The uniform plasma is created through the ionization of an ultra-low density (5 mg/c.c.) plastic foam by X-ray burst from the interaction of intense laser (I = 10{sup 14 }W/cm{sup 2}, 600 ps) with a thin Cu foil. 2D Particle-In-Cell (PIC) simulation well reproduces the collimated electron beam with a strong magnetic field in the region of the laser pulse propagation. To understand the physical mechanism of the collimation, we calculate energetic electron motion in the magnetic field obtained from the 2D PIC simulation. As the results, the strong magnetic field (300 MG) collimates electrons with energy over a few MeV. This collimation mechanism may attract attention in many applications such as electron acceleration, electron microscope and fast ignition of laser fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary study of slow and fast ultrasonic waves using MR images of trabecular bone phantom

Cancellous bone is a complex tissue that performs physiological and biomechanical functions in all vertebrates. It is made up of trabeculae that, from a simplified structural viewpoint, can be considered as plates and beams in a hyperstatic structure that change with time leading to osteoporosis. Several methods has been developed to study the trabecular bone microstructure among them is the Biot’s model which predicts the existence of two longitudinal waves in porous media; the slow and the fast waves, that can be related to porosity of the media. This paper is focused on the experimental detection of the two Biot’s waves of a trabecular bone phantom, consisting of a trabecular network of inorganic hydroxyapatite. Experimental measurements of both waves were performed using through transmission ultrasound. Results had shown clearly that the propagation of two waves propagation is transversal to the trabecular alignment. Otherwise the waves are overlapped and a single wave seems to be propagated. To validate these results, magnetic resonance images were acquired to assess the trabecular direction, and to assure that the pulses correspond to the slow and fast waves. This approach offers a methodology for non-invasive studies of trabecular bones.

60 APPLIED LIFE SCIENCES↗

Time-resolved spectroscopy using a chopper wheel as a fast shutter

Widely available, small form-factor, fiber-coupled spectrometers typically have a minimum exposure time measured in milliseconds, and thus cannot be used directly for time-resolved measurements at the microsecond level. Spectroscopy at these faster time scales is typically done with an intensified charge coupled device (CCD) system where the image intensifier acts as a “fast” electronic shutter for the slower CCD array. In this paper, we describe simple modifications to a commercially available chopper wheel system to allow it to be used as a “fast” mechanical shutter for gating a fiber-coupled spectrometer to achieve microsecond-scale time-resolved optical measurements of a periodically pulsed light source. With the chopper wheel synchronized to the pulsing of the light source, the time resolution can be set to a small fraction of the pulse period by using a chopper wheel with narrow slots separated by wide spokes. Different methods of synchronizing the chopper wheel and pulsing of the light sources are explored. The capability of the chopper wheel system is illustrated with time-resolved measurements of pulsed plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Level monitoring system with pulsating sensor—Application to online level monitoring of dashpots in a fast breeder reactor

An innovative continuous type liquid level monitoring system constructed by using a new class of sensor, viz., pulsating sensor, is presented. This device is of industrial grade and it is exclusively used for level monitoring of any non conducting liquid. This instrument of unique design is suitable for high resolution online monitoring of oil level in dashpots of a sodium-cooled fast breeder reactor. The sensing probe is of capacitance type robust probe consisting of a number of rectangular mirror polished stainless steel (SS-304) plates separated with uniform gaps. The performance of this novel instrument has been thoroughly investigated. The precision, sensitivity, response time, and the lowest detection limit in measurement using this device are <0.01 mm, ∼100 Hz/mm, ∼1 s, and ∼0.03 mm, respectively. The influence of temperature on liquid level is studied and the temperature compensation is provided in the instrument. The instrument qualified all recommended tests, such as environmental, electromagnetic interference and electromagnetic compatibility, and seismic tests prior to its deployment in nuclear reactor. With the evolution of this level measurement approach, it is possible to provide dashpot oil level sensors in fast breeder reactor for the first time for continuous measurement of oil level in dashpots of Control and Safety Rod Drive Mechanism during reactor operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast magnetic reconnection due to anisotropic electron pressure

A new regime of fast magnetic reconnection with an out-of-plane (guide) magnetic field is reported in which the key role is played by an electron pressure anisotropy described by the Chew-Goldberger-Low gyrotropic equations of state in the generalized Ohm's law, which even dominates the Hall term. A description of the physical cause of this behavior is provided and two-dimensional fluid simulations are used to confirm the results. The electron pressure anisotropy causes the out-of-plane magnetic field to develop a quadrupole structure of opposite polarity to the Hall magnetic field and gives rise to dispersive waves. In addition to being important for understanding what causes reconnection to be fast, this mechanism should dominate in plasmas with low plasma beta and a high in-plane plasma beta with electron temperature comparable to or larger than ion temperature, so it could be relevant in the solar wind and some tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pyrolytic oil of banana (Musa spp.) pseudo-stem via fast process

This study was an attempt to produce bio-oil from banana pseudo-stem, a waste of banana cultivation, using fast pyrolysis technology. The compositions were determined and the thermal degradation behaviour of the raw material was analyzed using Perkin-Elmer Simultaneous Thermal Analyzer (STA) 6000. A 300 g/h fluidized bed bench scale fast pyrolysis unit, assembled with double screw feeders and cyclones, operating at atmospheric pressure, was used to obtain the pyrolysis liquid. The study involves the impact of the following key variables; the reactor temperature in the range of 450–650 °C, and the residence time in the range of 1.00–3.00 s. The particle size was set at 224-400 µm. The properties of the liquid product were analyzed for calorific heating value, pH value, conductivity, water and char content. The basic functional groups of the compositions were also determined using FTIR. The properties of the liquid product were compared with other wood derived bio-oil. The pyrolysis liquids derived from banana pseudo-stem were found to be in an aqueous phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A fast and reliable readout method for quantitative analysis of surface-enhanced Raman scattering nanoprobes on chip surface

Surface-enhanced Raman scattering techniques have been widely used for bioanalysis due to its high sensitivity and multiplex capacity. However, the point-scanning method using a micro-Raman system, which is the most common method in the literature, has a disadvantage of extremely long measurement time for on-chip immunoassay adopting a large chip area of approximately 1-mm scale and confocal beam point of ca. 1-μm size. Alternative methods such as sampled spot scan with high confocality and large-area scan method with enlarged field of view and low confocality have been utilized in order to minimize the measurement time practically. In this study, we analyzed the two methods in respect of signal-to-noise ratio and sampling-led signal fluctuations to obtain insights into a fast and reliable readout strategy. On this basis, we proposed a methodology for fast and reliable quantitative measurement of the whole chip area. The proposed method adopted a raster scan covering a full area of 100 μm × 100 μm region as a proof-of-concept experiment while accumulating signals in the CCD detector for single spectrum per frame. One single scan with 10 s over 100 μm × 100 μm area yielded much higher sensitivity compared to sampled spot scanning measurements and no signal fluctuations attributed to sampled spot scan. This readout method is able to serve as one of key technologies that will bring quantitative multiplexed detection and analysis into practice.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of fast drifting electrons on electron temperature measurement with a triple Langmuir probe

Triple Langmuir Probe (TLP) is a widely used diagnostics for instantaneous measurement of electron temperature and density in low temperature laboratory plasmas as well as in edge region of fusion plasma devices. Presence of a moderately energetic flowing electron component, constituting only a small fraction of the bulk electrons, is also a generally observed scenario in plasma devices, where plasmas are produced by electron impact ionization of neutrals. A theoretical analysis of its effect on interpretation of the TLP data for bulk electron temperature measurement is presented here assuming electron velocity distribution is not deviating substantially from a Maxwellian. The study predicts conventional expression from standard TLP theory to give overestimated value of bulk electron temperature. Correction factor is significant and largely depends on population density, temperature, and energy of the fast component. Experimental verification of theoretical results is obtained in the magnetized plasma linear experimental device of Saha Institute of Nuclear Physics where plasma is produced by an electron cyclotron resonance method and known to have a fast flowing electron component.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interaction of fast magnetoacoustic solitons in dense plasmas

One dimensional propagation of fast magnetoacoustic solitary waves in dense plasmas with degenerate electrons is investigated in this paper in the small amplitude limit. In this regard, Korteweg deVries equation is derived and discussed using the plasma parameters that are typically found in white dwarf stars. The interaction of fast magnetoacoustic solitons is explored by using the Hirota bilinear formalism, which admits multi soliton solutions. It is observed that the values of the propagation vectors determine the interaction of solitary waves. It is further noted that the amplitude of the respective solitary waves remain unchanged after the interaction; however, they do experience a phase shift.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modeling of high harmonic fast wave current drive on EAST tokamak

High harmonic fast waves (HHFW) are among the candidates for non-inductive current drive (CD), which is essential for long-pulse or steady-state operation of tokamaks. Current driven with HHFW in EAST tokamak plasmas is numerically studied. The HHFW CD efficiency is found to increase non-monotonically with the wave frequency, and this phenomenon is attributed to the multi-pass absorption of HHFW. The sensitivity of CD efficiency to the value of the parallel refraction index of the launched wave is confirmed. The quasilinear effects, assessed as significant in HHFW current drive with the GENRAY/CQL3D package, cause a significant increase in CD efficiency as RF power is increased, which is very different from helicon current drive. Simulations for a range of toroidal dc electric fields, in combination with a range of fast wave powers, are also presented and indicate that the presence of the DC field can also enhance the CD efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast magnetic reconnection supported by sporadic small-scale Petschek-type shocks

Standard magnetohydrodynamic (MHD) theory predicts reconnection rate that is far too slow to account for a wide variety of reconnection events observed in space and laboratory plasmas. Therefore, it was commonly accepted that some non-MHD (kinetic) effects play a crucial role in fast reconnection. A recently renewed interest in simple MHD models is associated with the so-called plasmoid instability of reconnecting current sheets. Although it is now evident that this effect can significantly enhance the rate of reconnection, many details of the underlying multiple-plasmoid process still remain controversial. Here, we report results of a high-resolution computer simulation which demonstrate that fast albeit intermittent magnetic reconnection is sustained by numerous small-scale Petschek-type shocks spontaneously formed in the current sheet due to its plasmoid instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗