Search NASA⌕ Search

SEARCH · Search NASA

Results for “Factor Analysis, Statistical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Quantifying the impact of operating temperature on cracking in battery electrodes, using super-resolution of microscopy images and stereology

There are numerous factors that can have an impact on the degradation behavior of batteries, such as the number of recharge cycles or the charge rate. Here, we investigate the influence of operating temperature on the structural degradation of the microstructure in lithium-ion positive electrodes. For that purpose, the microstructure is characterized for cathodes which have been cycled for 200 cycles under 6C (10-minute) charging at different operating temperatures, namely, 20°C, 30°C, 40°C, and 50°C. For each operating condition scanning electron microscopy (SEM) images of cross-sectioned Li x Ni 0.5 Mn 0.3 Co 0.2 O 2 (NMC532) electrodes have been analyzed, to determine structural descriptors such as global particle porosity, crack size/length/width distribution, and porosity and specific surface area distribution of individual particles. Additionally, a stereological method has been deployed to investigate the local particle porosity as a function of distance to the particle center. Results show that particle porosity increases with increasing cycling temperature. Particle porosity is greatest at the particle center and decreases along the particle radius to the exterior. Particle surface area is similar across the four cycling-temperature aging conditions.

25 ENERGY STORAGE↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Easy Tool to Predict Survival in Patients Receiving Radiation Therapy for Painful Bone Metastases

Purpose: Patients with bone metastases have a widely varying survival. A reliable estimation of survival is needed for appropriate treatment strategies. Our goal was to assess the value of simple prognostic factors, namely, patient and tumor characteristics, Karnofsky performance status (KPS), and patient-reported scores of pain and quality of life, to predict survival in patients with painful bone metastases. Methods and Materials: In the Dutch Bone Metastasis Study, 1157 patients were treated with radiation therapy for painful bone metastases. At randomization, physicians determined the KPS; patients rated general health on a visual analogue scale (VAS-gh), valuation of life on a verbal rating scale (VRS-vl) and pain intensity. To assess the predictive value of the variables, we used multivariate Cox proportional hazard analyses and C-statistics for discriminative value. Of the final model, calibration was assessed. External validation was performed on a dataset of 934 patients who were treated with radiation therapy for vertebral metastases. Results: Patients had mainly breast (39%), prostate (23%), or lung cancer (25%). After a maximum of 142 weeks' follow-up, 74% of patients had died. The best predictive model included sex, primary tumor, visceral metastases, KPS, VAS-gh, and VRS-vl (C-statistic = 0.72, 95% CI = 0.70-0.74). A reduced model, with only KPS and primary tumor, showed comparable discriminative capacity (C-statistic = 0.71, 95% CI = 0.69-0.72). External validation showed a C-statistic of 0.72 (95% CI = 0.70-0.73). Calibration of the derivation and the validation dataset showed underestimation of survival. Conclusion: In predicting survival in patients with painful bone metastases, KPS combined with primary tumor was comparable to a more complex model. Considering the amount of variables in complex models and the additional burden on patients, the simple model is preferred for daily use. In addition, a risk table for survival is provided.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiotherapy in the Treatment of Patients With Unresectable Extrahepatic Cholangiocarcinoma

Purpose: Extrahepatic cholangiocarcinoma is an uncommon but lethal malignancy. We analyzed the role of definitive chemoradiotherapy for patients with nonmetastatic, locally advanced extrahepatic cholangiocarcinoma treated at a single institution. Methods and Materials: This retrospective analysis included 37 patients who underwent external beam radiation therapy (EBRT) with concurrent chemotherapy and/or brachytherapy (BT) for locally advanced extrahepatic cholangiocarcinoma. Local control (LC) and overall survival (OS) were assessed, and univariate regression analysis was used to evaluate the effects of patient- and treatment-related factors on clinical outcomes. Results: Twenty-three patients received EBRT alone, 8 patients received EBRT plus BT, and 6 patients received BT alone (median follow-up of 14 months). Two patients were alive without evidence of recurrence at the time of analysis. Actuarial OS and LC rates at 1 year were 59% and 90%, respectively, and 22% and 71%, respectively, at 2 years. Two patients lived beyond 5 years without evidence of recurrence. On univariate analysis, EBRT with or without BT improved LC compared to BT alone (97% vs. 56% at 1 year; 75% vs. 56% at 2 years; p = 0.096). Patients who received EBRT alone vs. BT alone also had improved LC (96% vs. 56% at 1 year; 80% vs. 56% at 2 years; p = 0.113). Age, gender, tumor location (proximal vs. distal), histologic differentiation, EBRT dose ({<=} or >50 Gy), EBRT planning method (two-dimensional vs. three-dimensional), and chemotherapy were not associated with patient outcomes. Conclusions: Patients with locally advanced extrahepatic cholangiocarcinoma have poor survival. Long-term survival is rare. The majority of patients treated with EBRT had local control at the time of death, suggesting that symptoms due to the local tumor effect might be effectively controlled with radiation therapy, and EBRT is an important element of treatment. Novel treatment approaches are indicated in the therapy for this disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Climate-Related Trends of Within-Storm Intensities Using Dimensionless Temporal-Storm Distributions

Huff curves are probabilistic time distributions of rainfall expressed as dimensionless cumulative percentages of storm depth and duration. Previous studies have documented development factors, spatial robustness, and the utility of Huff curves in practical applications. However, the effects of trending rainfall on Huff curve intensity patterns have not yet been studied. As such, the goal of this paper is to fill this gap by studying Huff curve patterns in a watershed with demonstrated increasing trends of temperature and precipitation, with the intention that it can be generalized to other areas in the US and the world. To achieve this goal, the high temporal resolution precipitation data collected from a high spatial density, 72-year precipitation-gauge network on the 4.25-km 2 North Appalachian Experimental Watershed in east-central Ohio were used. Seasonal storm pattern trends from 1939 to 2010 were investigated using dimensionless depth (with the frequency of 50%, $d_{50}$) and the curve variability $(V = d_{80} - d_{20})$ at three dimensionless within-storms time periods (three verticals). The Spearman rank correlation procedure (correlation coefficient, ρ and significance probability, p) was used to statistically determine trends over time using 8 periods of 4-season sets of Huff curves over the 72 years. Two averages of ρ and p were computed: (1) by averaging the individual ρ and p obtained from 10 gauges (AvgI); and (2) by grouped averaging of all individual gauge values of $d_{50}$ and V and then computing ρ and p (AvgG). The test results of individual gauges showed that 4 cases for $d_{50}$ and 23 cases for V were significant for all seasons and verticals (total of 120 cases for each variable). The test results of AvgI for $d_{50}$ and V and AvgG for $d_{50}$ showed no significant trends in all seasons and verticals. Only the AvgG for V led to a significant trend for V in spring and fall at different times within storm patterns. The data do not provide sufficient evidence at the p=0.05 significance level to reject the null hypothesis of unchanging position of the dimensionless depth of the 50% Huff curves for individual or averages for all seasons and verticals. Also, there is insufficient evidence to reject the null hypothesis of unchanging variability, V, using the average ρ of individual gauges (AvgI for V) for all seasons and verticals. AvgG results showed a significant trend in V; however, this analysis may be affected by the nonindependence of storm data. The results suggest that it is likely that there is little if any effect of trending climate over approximately 70 years on Huff curve patterns. The results of this study add to the robustness characteristics of Huff curves and to their potential use in hydrological practice as design storms, as the foundation of stochastic storm generation, and for storm disaggregation, and they deserve further investigation. These different forms of inputs to watershed models have the potential to improve runoff estimation. The results suggest that, if verified in other studies, they have applicability to provide useful stationary precipitation patterns across the US and other areas of the world in areas of nonstationary climate. Also, individual rain gauge data may not be representative of trends even over small areas, and seasonal differences were noticeable as found in other studies. Recommendations are provided.

54 ENVIRONMENTAL SCIENCES↗

Towards application of a neutron cross-section uncertainty propagation capability in the criticality safety methodology - 14434

At the Paul Scherrer Institute (PSI) the methodology for criticality safety evaluations (CSE) used for Swiss applications is focused, following common practice, on establishing an upper subcriticality limit (USL) for the effective neutron multiplication factor (k{sub eff}), based on a statistical evaluation of the obtained validation results in terms of the calculated-to-benchmark k{sub eff} values. Recently, a new computational tool referred to as NUSS (Nuclear data Uncertainty Stochastic Sampling) was developed in order to propagate neutron-nuclear data (ND) uncertainties in calculations with Monte Carlo transport codes in combination with general-purpose ND libraries in ACE format. Thereby, this tool should now allow for a quantification of ND data uncertainties in CSE and to introduce these into the CSE criteria definition. This paper concerns an application of the NUSS methodology for criticality validation studies. Calculated k{sub eff} uncertainty estimations were obtained for the current PSI validation suite including in total 149 critical benchmark configurations for which in-house MCNP(X) models were developed, covering both uranium and mixed uranium-plutonium oxide fuels. The MCNPX-2.7.0 code was used together with the ENDF/B-VII.1 ND library while the ND variance-covariance matrixes (VCM) were taken from both SCALE-6.0 44-group libraries and also from ENDF/B-VII.1 files. Based on the newly obtained information on the uncertainties, a re-assessment of the lower tolerance bound (LTB) for k{sub eff} using the total uncertainties as weighting factors is proposed as means for the present PSI CSE methodology upgrade and some possible directions of further methodology enhancements are discussed next. (authors)

42 ENGINEERING↗

Shielding analysis and design of the KIPT experimental neutron source facility of Ukraine.

Argonne National Laboratory (ANL) of USA and Kharkov Institute of Physics and Technology (KIPT) of Ukraine have been collaborating on the conceptual design development of an experimental neutron source facility based on the use of an electron accelerator driven subcritical (ADS) facility [1]. The facility uses the existing electron accelerators of KIPT in Ukraine. The neutron source of the sub-critical assembly is generated from the interaction of 100 KW electron beam with a natural uranium target. The electron beam has a uniform spatial distribution and the electron energy in the range of 100 to 200 MeV, [2]. The main functions of the facility are the production of medical isotopes and the support of the Ukraine nuclear power industry. Reactor physics experiments and material performance characterization will also be carried out. The subcritical assembly is driven by neutrons generated by the electron beam interactions with the target material. A fraction of these neutrons has an energy above 50 MeV generated through the photo nuclear interactions. This neutron fraction is very small and it has an insignificant contribution to the subcritical assembly performance. However, these high energy neutrons are difficult to shield and they can be slowed down only through the inelastic scattering with heavy isotopes. Therefore the shielding design of this facility is more challenging relative to fission reactors. To attenuate these high energy neutrons, heavy metals (tungsten, iron, etc.) should be used. To reduce the construction cost, heavy concrete with 4.8 g/cm{sup 3} density is selected as a shielding material. The iron weight fraction in this concrete is about 0.6. The shape and thickness of the heavy concrete shield are defined to reduce the biological dose equivalent outside the shield to an acceptable level during operation. At the same time, special attention was give to reduce the total shield mass to reduce the construction cost. The shield design is configured to maintain the biological dose equivalent during operation {le} 0.5 mrem/h inside the subcritical hall, which is five times less than the allowable dose for working forty hours per week for 50 weeks per year. This study analyzed and designed the thickness and the shape of the radial and top shields of the neutron source based on the biological dose equivalent requirements inside the subcritical hall during operation. The Monte Carlo code MCNPX is selected because of its capabilities for transporting electrons, photons, and neutrons. Mesh based weight windows variance reduction technique is utilized to estimate the biological dose outside the shield with good statistics. A significant effort dedicated to the accurate prediction of the biological dose equivalent outside the shield boundary as a function of the shield thickness without geometrical approximations or material homogenization. The building wall was designed with ordinary concrete to reduce the biological dose equivalent to the public with a safety factor in the range of 5 to 20.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Stereotactic Radiosurgery for Patients With Brain Metastases From Small Cell Lung Cancer

Background: Patients with small-cell lung cancer have a high likelihood of developing brain metastases. Many of these patients will have prophylactic cranial irradiation (PCI) or eventually undergo whole brain radiation therapy (WBRT). Despite these treatments, a large number of these patients will have progression of their intracranial disease and require additional local therapy. Stereotactic radiosurgery (SRS) is an important treatment option for such patients. Methods: We retrospectively reviewed the charts of 44 patients with brain metastases from small-cell lung cancer treated with gamma knife SRS. Multivariate analysis was used to determine significant prognostic factors influencing survival. Results: The median follow-up from SRS in this patient population was 9 months (1-49 months). The median overall survival (OS) was 9 months after SRS. Karnofsky performance status (KPS) and combined treatment involving WBRT and SRS within 4 weeks were the two factors identified as being significant predictors of increased OS (p = 0.033 and 0.040, respectively). When comparing all patients, patients treated with a combined approach had a median OS of 14 months compared to 6 months if SRS was delivered alone. We also compared the OS times from the first definitive radiation: WBRT, WBRT and SRS if combined therapy was used, and SRS if the patient never received WBRT. The median survival for those groups was 12, 14, and 13 months, respectively, p = 0.19. Seventy percent of patients had follow-up magnetic resonance imaging available for review. Actuarial local control at 6 months and 12 months was 90% and 86%, respectively. Only 1 patient (2.2%) had symptomatic intracranial swelling related to treatment, which responded to a short course of steroids. New brain metastases outside of the treated area developed in 61% of patients at a median time of 7 months; 81% of these patients had received previous WBRT. Conclusions: Stereotactic radiosurgery for small-cell lung carcinoma brain metastases provided safe and effective local tumor control in the majority of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose-Rate Brachytherapy for Non-Small-Cell Lung Carcinoma: A Retrospective Study of 226 Patients

Purpose: To evaluate the efficacy and toxicity of high-dose-rate (HDR) brachytherapy in patients with inoperable endobronchial carcinoma. Methods and Materials: We retrospectively reviewed the records (April 1991-May 2004) of patients with non-small-cell carcinoma, with no extrabronchial spread on computed tomography scans, who underwent HDR brachytherapy because of contraindications to surgery and external beam radiation therapy. Kaplan-Meier survival curves were compared by the log-rank test. Prognostic factors were analyzed by multivariate analysis. Results: 226 patients (223 men, 3 women, mean age: 62.2 years (range, 40-84)) were included. Of those, 217 (97%) had squamous cell carcinoma (Tis/T1/T2/Tx: 60/153/9/4). Dose was prescribed at 1 cm from the radius (24-35 Gy in 4-6 fractions). Mean follow-up was 30.4 months (range, 9-116). Complete endoscopic response rate was 93.6% at 3 months. One hundred twenty-eight patients (56%) died of intercurrent disease (n = 45), local failure (n = 36), metastasis (n = 10), local failure and metastasis (n = 11), complications (n = 13), and other causes (n = 12). The 2-year and 5-year survival rates were, respectively, 57% and 29% (overall) (median, 28.6 months), 81% and 56% (cancer-specific), and 68% and 50% (local disease-free). Acute toxicity included pneumothorax (1.5%) and mucosal inflammation (10%). Late complications were hemoptysis (6.6% with 5% of fatalities), bronchitis (19.5%), and necrosis (3.5%). In multivariate analysis, a distal tumor location and the use of two catheters were associated with improved local disease-free survival (p = 0.003 and p = 0.007, respectively) and a distal tumor location with improved overall survival (p = 0.0001). Conclusions: This large retrospective study confirms that HDR brachytherapy is an efficient and safe treatment in patients with inoperable endobronchial carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Differences in serum concentrations of organochlorine compounds by occupational social class in pancreatic cancer

Background: The relationships between social factors and body concentrations of environmental chemical agents are unknown in many human populations. Some chemical compounds may play an etiopathogenic role in pancreatic cancer. Objective: To analyze the relationships between occupational social class and serum concentrations of seven selected organochlorine compounds (OCs) in exocrine pancreatic cancer: dichlorodiphenyltrichloroethane (p,p'-DDT), dichlorodiphenyldichloroethene (p,p'-DDE), 3 polychlorinated biphenyls (PCBs), hexachlorobenzene, and {beta}-hexachlorocyclohexane. Methods: Incident cases of exocrine pancreatic cancer were prospectively identified, and interviewed face-to-face during hospital admission (n=135). Serum concentrations of OCs were analyzed by high-resolution gas chromatography with electron-capture detection. Social class was classified according to occupation. Results: Multivariate-adjusted concentrations of all seven compounds were higher in occupational social classes IV-V (the less affluent) than in classes I-II; they were higher as well in class III than in classes I-II for four compounds. Concentrations of six OCs were higher in manual workers than in non-manual workers (p<0.05 for PCBs). Social class explained statistically between 3.7% and 5.7% of the variability in concentrations of PCBs, and 2% or less variability in the other OCs. Conclusions: Concentrations of most OCs were higher in the less affluent occupational social classes. In pancreatic cancer the putative causal role of these persistent organic pollutants may not be independent of social class. There is a need to integrate evidence on the contribution of different social processes and environmental chemical exposures to the etiology of pancreatic and other cancers.

60 APPLIED LIFE SCIENCES↗

A Bayesian Analysis of SDSS J0914+0853, a Low-mass Dual AGN Candidate

We present the first results from Bayesian AnalYsis of Multiple AGN in X-rays (BAYMAX), a tool that uses a Bayesian framework to quantitatively evaluate whether a given Chandra observation is more likely a single or dual point source. Although the most robust method of determining the presence of dual active galactic nuclei (AGNs) is to use X-ray observations, only sources that are widely separated relative to the instrumentʼs point-spread function are easy to identify. It becomes increasingly difficult to distinguish dual AGNs from single AGNs when the separation is on the order of Chandraʼs angular resolution (<1″). Using likelihood models for single and dual point sources, BAYMAX quantitatively evaluates the likelihood of an AGN for a given source. Specifically, we present results from BAYMAX analyzing the lowest-mass dual AGN candidate to date, SDSS J0914+0853, where archival Chandra data shows a possible secondary AGN ∼ 0"3 from the primary. Analyzing a new 50 ks Chandra observation, results from BAYMAX shows that SDSS J0914+0853 is most likely a single AGN with a Bayes factor of 13.5 in favor of a single point source model. Further, posterior distributions from the dual point source model are consistent with emission from a single AGN. We find a very low probability of SDSS J0914+0853 being a dual AGN system with a flux ratio f>0.3 and separation r>0"3. Overall, BAYMAX will be an important tool for correctly classifying candidate dual AGNs in the literature, as well as studying the dual AGN population where past spatial resolution limits have prevented systematic analyses.

Active galaxies↗

Invariant discovery of features across multiple length scales: Applications in microscopy and autonomous materials characterization

Physical imaging is a foundational characterization method in areas from condensed matter physics and chemistry to astronomy and spans length scales from atomic to universe. Images encapsulate crucial data regarding atomic bonding, materials microstructures, and dynamic phenomena such as microstructural evolution and turbulence, among other phenomena. The challenge lies in effectively extracting and interpreting this information. Variational Autoencoders (VAEs) have emerged as powerful tools for identifying the underlying factors of variation in image data, providing a systematic approach to distilling meaningful patterns from complex data sets. However, a significant hurdle in their application is the definition and selection of appropriate descriptors reflecting local structures. Here, we introduce the scale-invariant VAE approach (SI-VAE) based on the progressive training of the VAE with the descriptors sampled at different length scales. The SI-VAE allows the discovery of the length scale-dependent factors of variation in the system. Here, we illustrate this approach using the ferroelectric domain images and generalize it to the movies of the electron-beam induced phenomena in graphene and topography evolution across combinatorial libraries. This approach can further be used to initialize the decision making in automated experiments including structure–property discovery and can be applied across a broad range of imaging methods. This approach is universal and can be applied to any spatially resolved data including both experimental imaging studies and simulations, and can be particularly useful for exploration of phenomena such as turbulence and scale-invariant transformation fronts.

36 MATERIALS SCIENCE↗

A comparative study of two-way and offline coupled WRF v3.4 and CMAQ v5.0.2 over the contiguous US: performance evaluation and impacts of chemistry–meteorology feedbacks on air quality

The two-way coupled Weather Research and Forecasting and Community Multiscale Air Quality (WRF-CMAQ) model has been developed to more realistically represent the atmosphere by accounting for complex chemistry–meteorology feedbacks. In this study, we present a comparative analysis of two-way (with consideration of both aerosol direct and indirect effects) and offline coupled WRF v3.4 and CMAQ v5.0.2 over the contiguous US. Long-term (5 years from 2008 to 2012) simulations using WRF-CMAQ with both offline and two-way coupling modes are carried out with anthropogenic emissions based on multiple years of the U.S. National Emission Inventory and chemical initial and boundary conditions derived from an advanced Earth system model (i.e., a modified version of the Community Earth System Model/Community Atmospheric Model). The comprehensive model evaluations show that both two-way WRF-CMAQ and WRF-only simulations perform well for major meteorological variables such as temperature at 2 m, relative humidity at 2 m, wind speed at 10 m, precipitation (except for against the National Climatic Data Center data), and shortwave and longwave radiation. Both two-way and offline CMAQ also show good performance for ozone (O3) and fine particulate matter (PM 2.5 ). Due to the consideration of aerosol direct and indirect effects, two-way WRF-CMAQ shows improved performance over offline coupled WRF and CMAQ in terms of spatiotemporal distributions and statistics, especially for radiation, cloud forcing, O 3 , sulfate, nitrate, ammonium, elemental carbon, tropospheric O 3 residual, and column nitrogen dioxide (NO 2 ). For example, the mean biases have been reduced by more than 10 W m –2 for shortwave radiation and cloud radiative forcing and by more than 2 ppb for max 8 h O 3 . However, relatively large biases still exist for cloud predictions, some PM 2.5 species, and PM 10 that warrant follow-up studies to better understand those issues. The impacts of chemistry–meteorological feedbacks are found to play important roles in affecting regional air quality in the US by reducing domain-average concentrations of carbon monoxide (CO), O 3 , nitrogen oxide (NO x ), volatile organic compounds (VOCs), and PM 2.5 by 3.1 % (up to 27.8 %), 4.2 % (up to 16.2 %), 6.6 % (up to 50.9 %), 5.8 % (up to 46.6 %), and 8.6 % (up to 49.1 %), respectively, mainly due to reduced radiation, temperature, and wind speed. The overall performance of the two-way coupled WRF-CMAQ model achieved in this work is generally good or satisfactory and the improved performance for two-way coupled WRF-CMAQ should be considered along with other factors in developing future model applications to inform policy making.

58 GEOSCIENCES↗

Bayesian network ensemble as a multivariate strategy to predict radiation pneumonitis risk

Purpose: Prediction of radiation pneumonitis (RP) has been shown to be challenging due to the involvement of a variety of factors including dose–volume metrics and radiosensitivity biomarkers. Some of these factors are highly correlated and might affect prediction results when combined. Bayesian network (BN) provides a probabilistic framework to represent variable dependencies in a directed acyclic graph. The aim of this study is to integrate the BN framework and a systems’ biology approach to detect possible interactions among RP risk factors and exploit these relationships to enhance both the understanding and prediction of RP. Methods: The authors studied 54 nonsmall-cell lung cancer patients who received curative 3D-conformal radiotherapy. Nineteen RP events were observed (common toxicity criteria for adverse events grade 2 or higher). Serum concentration of the following four candidate biomarkers were measured at baseline and midtreatment: alpha-2-macroglobulin, angiotensin converting enzyme (ACE), transforming growth factor, interleukin-6. Dose-volumetric and clinical parameters were also included as covariates. Feature selection was performed using a Markov blanket approach based on the Koller–Sahami filter. The Markov chain Monte Carlo technique estimated the posterior distribution of BN graphs built from the observed data of the selected variables and causality constraints. RP probability was estimated using a limited number of high posterior graphs (ensemble) and was averaged for the final RP estimate using Bayes’ rule. A resampling method based on bootstrapping was applied to model training and validation in order to control under- and overfit pitfalls. Results: RP prediction power of the BN ensemble approach reached its optimum at a size of 200. The optimized performance of the BN model recorded an area under the receiver operating characteristic curve (AUC) of 0.83, which was significantly higher than multivariate logistic regression (0.77), mean heart dose (0.69), and a pre-to-midtreatment change in ACE (0.66). When RP prediction was made only with pretreatment information, the AUC ranged from 0.76 to 0.81 depending on the ensemble size. Bootstrap validation of graph features in the ensemble quantified confidence of association between variables in the graphs where ten interactions were statistically significant. Conclusions: The presented BN methodology provides the flexibility to model hierarchical interactions between RP covariates, which is applied to probabilistic inference on RP. The authors’ preliminary results demonstrate that such framework combined with an ensemble method can possibly improve prediction of RP under real-life clinical circumstances such as missing data or treatment plan adaptation.

60 APPLIED LIFE SCIENCES↗

Pelvic Lymph Node Status Assessed by 18F-Fluorodeoxyglucose Positron Emission Tomography Predicts Low-Risk Group for Distant Recurrence in Locally Advanced Cervical Cancer: A Prospective Study

Purpose: To develop a prediction model to identify a low-risk group for distant recurrence in patients with locally advanced cervical cancer treated by concurrent chemoradiation. Methods and Materials: Prospectively, 62 patients with locally advanced cervical cancer were recruited as a training cohort. Clinical variables and parameters obtained from positron emission tomography (PET) and magnetic resonance imaging were analyzed by logistic regression. For the test set, 54 patients were recruited independently. To identify the low-risk group, negative likelihood ratio (LR) less than 0.2 was set to be a cutoff. Results: Among the training cohort, multivariate logistic analysis revealed that advanced International Federation of Gynecology and Obstetrics (FIGO) stage and a high serum squamous cancer cell (SCC) antigen level were significant risk factors (p = 0.015 and 0.025, respectively). Using the two parameters, criteria to determine a low-risk subset for distant recurrence were postulated: (1) FIGO Stage IIB or less and (2) pretreatment SCC < 2.4 (Model A). Positive pelvic node on PET completely predicted all cases with distant recurrence and thus was considered as another prediction model (Model B). In the test cohort, although Model A did not showed diagnostic performance, Model B completely predicted all cases with distant recurrence and showed a sensitivity of 100% with negative LR of 0. Across the training and test cohort (n = 116), the false negative rate was 0 (95% confidence interval 0%-7.6%). Conclusions: Positive pelvic node on PET is a useful marker in prediction of distant recurrence in patients with locally advanced cervical cancer who are treated with concurrent chemoradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Protective effect of N-acetyl-L-cysteine against disulfiram-induced oxidative stress and apoptosis in V79 cells

This work investigated the effect of N-acetyl-L-cysteine (NAC) on disulfiram (DSF) induced oxidative stress in Chinese hamster fibroblast cells (V79). An increase in oxidative stress induced by DSF was observed up to a 200 {mu}M concentration. It was evidenced by a statistically significant increase of both GSH{sub t} and GSSG levels, as well as elevated protein carbonyl (PC) content. There was no increase in lipid peroxidation (measured as TBARS). DSF increased CAT activity, but did not change SOD1 and SOD2 activities. Analysis of GSH related enzymes showed that DSF significantly increased GR activity, did not change Se-dependent GPx, but statistically significantly decreased non-Se-dependent GPx activity. DSF showed also pro-apoptotic activity. NAC alone did not produce any significant changes, besides an increase of GSH{sub t} level, in any of the variables measured. However, pre-treatment of cells with NAC ameliorated DSF-induced changes. NAC pre-treatment restored the viability of DSF-treated cells evaluated by Trypan blue exclusion assay and MTT test, GSSG level, and protein carbonyl content to the control values as well as it reduced pro-apoptotic activity of DSF. The increase of CAT and GR activity was not reversed. Activity of both GPx was significantly increased compared to their values after DSF treatment. In conclusion, oxidative properties are at least partially attributable to the cellular effects of disulfiram and mechanisms induced by NAC pre-treatment may lower or even abolish the observed effects. These observations illustrate the importance of the initial cellular redox state in terms of cell response to disulfiram exposure. -- Research Highlights: {yields}This report explores biological properties of disulfiram under a condition of modulated intra-cellular GSH level. It shows a protective role of N-acetyl-L-cysteine in V79 cells exposed to disulfiram (in GSH metabolism as well as in changes of antioxidant enzyme activity).

60 APPLIED LIFE SCIENCES↗

Estimation of breast percent density in raw and processed full field digital mammography images via adaptive fuzzy c-means clustering and support vector machine segmentation

Purpose: The amount of fibroglandular tissue content in the breast as estimated mammographically, commonly referred to as breast percent density (PD%), is one of the most significant risk factors for developing breast cancer. Approaches to quantify breast density commonly focus on either semiautomated methods or visual assessment, both of which are highly subjective. Furthermore, most studies published to date investigating computer-aided assessment of breast PD% have been performed using digitized screen-film mammograms, while digital mammography is increasingly replacing screen-film mammography in breast cancer screening protocols. Digital mammography imaging generates two types of images for analysis, raw (i.e., 'FOR PROCESSING') and vendor postprocessed (i.e., 'FOR PRESENTATION'), of which postprocessed images are commonly used in clinical practice. Development of an algorithm which effectively estimates breast PD% in both raw and postprocessed digital mammography images would be beneficial in terms of direct clinical application and retrospective analysis. Methods: This work proposes a new algorithm for fully automated quantification of breast PD% based on adaptive multiclass fuzzy c-means (FCM) clustering and support vector machine (SVM) classification, optimized for the imaging characteristics of both raw and processed digital mammography images as well as for individual patient and image characteristics. Our algorithm first delineates the breast region within the mammogram via an automated thresholding scheme to identify background air followed by a straight line Hough transform to extract the pectoral muscle region. The algorithm then applies adaptive FCM clustering based on an optimal number of clusters derived from image properties of the specific mammogram to subdivide the breast into regions of similar gray-level intensity. Finally, a SVM classifier is trained to identify which clusters within the breast tissue are likely fibroglandular, which are then aggregated into a final dense tissue segmentation that is used to compute breast PD%. Our method is validated on a group of 81 women for whom bilateral, mediolateral oblique, raw and processed screening digital mammograms were available, and agreement is assessed with both continuous and categorical density estimates made by a trained breast-imaging radiologist. Results: Strong association between algorithm-estimated and radiologist-provided breast PD% was detected for both raw (r= 0.82, p < 0.001) and processed (r= 0.85, p < 0.001) digital mammograms on a per-breast basis. Stronger agreement was found when overall breast density was assessed on a per-woman basis for both raw (r= 0.85, p < 0.001) and processed (0.89, p < 0.001) mammograms. Strong agreement between categorical density estimates was also seen (weighted Cohen's {kappa}{>=} 0.79). Repeated measures analysis of variance demonstrated no statistically significant differences between the PD% estimates (p > 0.1) due to either presentation of the image (raw vs processed) or method of PD% assessment (radiologist vs algorithm). Conclusions: The proposed fully automated algorithm was successful in estimating breast percent density from both raw and processed digital mammographic images. Accurate assessment of a woman's breast density is critical in order for the estimate to be incorporated into risk assessment models. These results show promise for the clinical application of the algorithm in quantifying breast density in a repeatable manner, both at time of imaging as well as in retrospective studies.

60 APPLIED LIFE SCIENCES↗

Robo-AO Kepler Survey. IV. The Effect of Nearby Stars on 3857 Planetary Candidate Systems

We present the overall statistical results from the Robo-AO Kepler planetary candidate survey, comprising of 3857 high-angular resolution observations of planetary candidate systems with Robo-AO, an automated laser adaptive optics system. These observations reveal previously unknown nearby stars blended with the planetary candidate host stars that alter the derived planetary radii or may be the source of an astrophysical false positive transit signal. In the first three papers in the survey, we detected 440 nearby stars around 3313 planetary candidate host stars. In this paper, we present observations of 532 planetary candidate host stars, detecting 94 companions around 88 stars; 84 of these companions have not previously been observed in high resolution. We also report 50 more-widely separated companions near 715 targets previously observed by Robo-AO. We derive corrected planetary radius estimates for the 814 planetary candidates in systems with a detected nearby star. If planetary candidates are equally likely to orbit the primary or secondary star, the radius estimates for planetary candidates in systems with likely bound nearby stars increase by a factor of 1.54, on average. We find that 35 previously believed rocky planet candidates are likely not rocky due to the presence of nearby stars. From the combined data sets from the complete Robo-AO KOI survey, we find that 14.5 ± 0.5% of planetary candidate hosts have a nearby star with 4″, while 1.2% have two nearby stars, and 0.08% have three. We find that 16% of Earth-sized, 13% of Neptune-sized, 14% of Saturn-sized, and 19% of Jupiter-sized planet candidates have detected nearby stars.

79 ASTRONOMY AND ASTROPHYSICS↗