Benchmark of FDNS CFD Code For Direct Connect RBCC Test Data

Computational Fluid Dynamics (CFD) analysis results are compared with experimental data from the Pennsylvania State University's (PSU) Propulsion Engineering Research Center (PERC) rocket based combined cycle (RBCC) rocket-ejector experiments. The PERC RBCC experimental hardware was in a direct-connect configuration in diffusion and afterburning (DAB) operation. The objective of the present work was to validate the Finite Difference Navier Stokes (FDNS) CFD code for the rocket-ejector mode internal fluid mechanics and combustion phenomena. A second objective was determine the best application procedures to use FDNS as a predictive/engineering tool. Three-dimensional CFD analysis was performed. Solution methodology and grid requirements are discussed. CFD results are compared to experimental data for static pressure, Raman Spectroscopy species distribution data and RBCC net thrust and specified impulse.

Ruf, J. H.↗

Overview of High-Power Wireless Charging Systems and Analysis of Polyphase Wireless Charging System Phase Winding and Resonant Tuning Network Connection Configurations

In spite of the high energy efficiency and environmental benefits of electric vehicles (EVs), adoption rates are increasing at a relatively slow pace, primarily because of EVs’ limited range and long charging durations. To reduce EV charging times to be comparable to refueling times of conventional vehicles, extreme fast charging systems are required. Such charging systems would reduce drivers’ range anxiety and enable long-distance interstate travel with EVs. Here, this substantial target in charging rates with 15–20 minutes of recharging times, requires research and development from grid to batteries with advanced charging systems. Wireless power transfer systems for EV charging applications are flexible, convenient, and highly efficient, and they allow automated charging. This paper reviews the power electronics and winding and resonant tuning network configurations for polyphase wireless power transfer systems for high-power wireless charging applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review on Protection Challenges of Transmission Lines Connected to Inverter-Based Resources

Utilities, university researchers, research institutes, and relay manufacturers have performed studies to investigate different aspects of high IBR penetration. Almost all studies support 1) creating international and national standards to regulate the IBRs, 2) revising engineering tools to address shortcomings, and 3) adjusting the protective relay settings to resolve protection problems. This paper summarizes the studies and research conducted in recent years to quantify the impact of IBR penetration on transmission line protection and to identify potential solutions to improve the dependability and reliability of grid protection systems.

14 SOLAR ENERGY↗

Approximate boundary condition procedure for the two-dimensional numerical solution of vortex wakes

Research on efficient computational methods for general vorticity fields has been conducted in connection with a need for basic research on vortex-dominated flows. The present investigation is concerned with the evolution of vortex wakes behind aircraft wings. An efficient procedure is presented for the calculation of the boundary values used in the numerical solution of the unsteady, incompressible, two-dimensional Navier-Stokes equations for an unbounded flow field. The extent of the computational grid can be reduced compared to methods utilizing standard boundary conditions, without loss of accuracy. The efficiencies realized make it feasible to calculate the vortex wake development for realistic wing configurations, including the merging of multiple vortices, for Reynolds numbers of about 10,000 based on wing chord.

Weston, R. P.↗

A MIMD implementation of a parallel Euler solver for unstructured grids

A mesh-vertex finite volume scheme for solving the Euler equations on triangular unstructured meshes is implemented on a MIMD (multiple instruction/multiple data stream) parallel computer. Three partitioning strategies for distributing the work load onto the processors are discussed. Issues pertaining to the communication costs are also addressed. We find that the spectral bisection strategy yields the best performance. The performance of this unstructured computation on the Intel iPSC/860 compares very favorably with that on a one-processor CRAY Y-MP/1 and an earlier implementation on the Connection Machine.

Venkatakrishnan, V.↗

One network metric datastore to track them all: the OSG network metric service

The Open Science Grid (OSG) relies upon the network as a critical part of the distributed infrastructures it enables. In 2012, OSG added a new focus area in networking with a goal of becoming the primary source of network information for its members and collaborators. This includes gathering, organizing, and providing network metrics to guarantee effective network usage and prompt detection and resolution of any network issues, including connection failures, congestion, and traffic routing. In September of 2015, this service was deployed into the OSG production environment. We will report on the creation, implementation, testing, and deployment of the OSG Networking Service. Starting from organizing the deployment of perfSONAR toolkits within OSG and its partners, to the challenges of orchestrating regular testing between sites, to reliably gathering the resulting network metrics and making them available for users, virtual organizations, and higher level services, all aspects of implementation will be reviewed. In particular, several higher-level services were developed to bring the OSG network service to its full potential. These include a web-based mesh configuration system, which allows central scheduling and management of all the network tests performed by the instances; a set of probes to continually gather metrics from the remote instances and publish it to different sources; a central network datastore (esmond), which provides interfaces to access the network monitoring information in close to real time and historically (up to a year) giving the state of the tests; and a perfSONAR infrastructure monitor system, ensuring the current perfSONAR instances are correctly configured and operating as intended. We will also describe the challenges we encountered in ongoing operations of the network service and how we have evolved our procedures to address those challenges. Finally we will describe our plans for future extensions and improvements to the service.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Black hole entropy and finite geometry

It is shown that the E{sub 6(6)} symmetric entropy formula describing black holes and black strings in D=5 is intimately tied to the geometry of the generalized quadrangle GQ(2, 4) with automorphism group the Weyl group W(E{sub 6}). The 27 charges correspond to the points and the 45 terms in the entropy formula to the lines of GQ(2, 4). Different truncations with 15, 11 and 9 charges are represented by three distinguished subconfigurations of GQ(2, 4), well known to finite geometers; these are the 'doily'[i.e. GQ(2, 2)] with 15, the 'perp set' of a point with 11, and the 'grid'[i.e. GQ(2, 1)] with nine points, respectively. In order to obtain the correct signs for the terms in the entropy formula, we use a noncommutative labeling for the points of GQ(2, 4). For the 40 different possible truncations with nine charges this labeling yields 120 Mermin squares--objects well known from studies concerning Bell-Kochen-Specker-like theorems. These results are connected to our previous ones obtained for the E{sub 7(7)} symmetric entropy formula in D=4 by observing that the structure of GQ(2, 4) is linked to a particular kind of geometric hyperplane of the split Cayley hexagon of order 2, featuring 27 points located on nine pairwise disjoint lines (a distance-3-spread). We conjecture that the different possibilities of describing the D=5 entropy formula using Jordan algebras, qubits and/or qutrits correspond to employing different coordinates for an underlying noncommutative geometric structure based on GQ(2, 4)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A multigrid solver for the semiconductor equations

We present a multigrid solver for the exponential fitting method. The solver is applied to the current continuity equations of semiconductor device simulation in two dimensions. The exponential fitting method is based on a mixed finite element discretization using the lowest-order Raviart-Thomas triangular element. This discretization method yields a good approximation of front layers and guarantees current conservation. The corresponding stiffness matrix is an M-matrix. 'Standard' multigrid solvers, however, cannot be applied to the resulting system, as this is dominated by an unsymmetric part, which is due to the presence of strong convection in part of the domain. To overcome this difficulty, we explore the connection between Raviart-Thomas mixed methods and the nonconforming Crouzeix-Raviart finite element discretization. In this way we can construct nonstandard prolongation and restriction operators using easily computable weighted L(exp 2)-projections based on suitable quadrature rules and the upwind effects of the discretization. The resulting multigrid algorithm shows very good results, even for real-world problems and for locally refined grids.

Bachmann, Bernhard↗

Investigation into Sizing Photovoltaic with Energy Storage for Off-Grid Transactive Scenarios

In this study, a novel sizing methodology was developed for centralized and interconnected operating strategies of transactive microgrids and several variables were investigated including starting month, initial charge of battery, load variability, unit cost of solar panels and energy storage, number of systems, climate, and required reliability to determine their effect on total cost. The centralized strategy improved cost by seven to ten percent compared to the isolated strategy in every case. The interconnected strategy saved an incremental amount of money consistently compared to the isolated standard. The number of connected systems was not a strong effect. It was thought that increasing the number of systems would increase the benefit of energy sharing. Climate zones studied (“Cold”; “Hot-Dry/Mixed Dry”; “Mixed Humid”; and “Cold but with lower solar irradiation”) showed a large variation on cost with the Hot-Dry/Mixed Dry being the least expensive and Cold, with lower solar irradiation being the most expensive. Cost sensitivity analysis was performed showing that the unit cost of solar has a greater effect on the total cost. Required reliability of power, measured in outage hours, exhibited an inverse relation with cost.

14 SOLAR ENERGY↗

Detection of False Data Injection Attacks in Battery Stacks Using Input Noise-Aware Nonlinear State Estimation and Cumulative Sum Algorithms

Grid-scale battery energy storage systems (BESSs) are vulnerable to false data injection attacks (FDIAs), which could be used to disrupt state of charge (SoC) estimation. Inaccurate SoC estimation has negative impacts on system availability, reliability, safety, and the cost of operation. In this article a combination of a Cumulative Sum (CUSUM) algorithm and an improved input noise-aware extended Kalman filter (INAEKF) is proposed for the detection and identification of FDIAs in the voltage and current sensors of a battery stack. The series-connected stack is represented by equivalent circuit models, the SoC is modeled with a charge reservoir model and the states are estimated using the INAEKF. Further, the root mean squared error of the states’ estimation by the modified INAEKF was found to be superior to the traditional EKF. By employing the INAEKF, this article addresses the research gap that many state estimators make asymmetrical assumptions about the noise corrupting the system. Additionally, the INAEKF estimates the input allowing for the identification of FDIA, which many alternative methods are unable to achieve. The proposed algorithm was able to detect attacks in the voltage and current sensors in 99.16% of test cases, with no false positives. Utilizing the INAEKF compared to the standard EKF allowed for the identification of FDIA in the input of the system in 98.43% of test cases.

25 ENERGY STORAGE↗

Optimal Electrification Using Renewable Energies: Microgrid Installation Model with Combined Mixture k-Means Clustering Algorithm, Mixed Integer Linear Programming, and Onsset Method

Optimal planning and design of microgrids are priorities in the electrification of off-grid areas. Indeed, in one of the Sustainable Development Goals (SDG 7), the UN recommends universal access to electricity for all at the lowest cost. Several optimization methods with different strategies have been proposed in the literature as ways to achieve this goal. This paper proposes a microgrid installation and planning model based on a combination of several techniques. The programming language Python 3.10 was used in conjunction with machine learning techniques such as unsupervised learning based on K-means clustering and deterministic optimization methods based on mixed linear programming. These methods were complemented by the open-source spatial method for optimal electrification planning: onsset. Four levels of study were carried out. The first level consisted of simulating the model obtained with a cluster, which is considered based on the elbow and k-means clustering method as a case study. The second level involved sizing the microgrid with a capacity of 40 kW and optimizing all the resources available on site. The example of the different resources in the Togo case was considered. At the third level, the work consisted of proposing an optimal connection model for the microgrid based on voltage stability constraints and considering, above all, the capacity limit of the source substation. Finally, the fourth level involved a planning study of electrification strategies based mainly on microgrids according to the study scenario. The results of the first level of study enabled us to obtain an optimal location for the centroid of the cluster under consideration, according to the different load positions of this cluster. Then, the results of the second level of study were used to highlight the optimal resources obtained and proposed by the optimization model formulated based on the various technology costs, such as investment, maintenance, and operating costs, which were based on the technical limits of the various technologies. In these results, solar systems account for 80% of the maximum load considered, compared to 7.5% for wind systems and 12.5% for battery systems. Next, an optimal microgrid connection model was proposed based on the constraints of a voltage stability limit estimated to be 10% of the maximum voltage drop. The results obtained for the third level of study enabled us to present selective results for load nodes in relation to the source station node. Finally, the last results made it possible to plan electrification using different network technologies and systems in the short and long term. The case study of Togo was taken into account. The various results obtained from the different techniques provide the necessary leads for a feasibility study for optimal electrification of off-grid areas using microgrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sandia's Current Energy Conversion module for Flexible-Mesh Delft3D flow solver v. 1.0

The DOE has funded Sandia National Labs (SNL) to develop an open-source modeling tool to guide the design and layout of marine hydrokinetic (MHK) arrays to maximize power production while minimizing environmental effects. This modeling framework simulates flows through and around a MHK arrays while quantifying environmental responses. As an augmented version of the Dutch company, Deltares’s, environmental hydrodynamics code, Delft3D, SNL-Delft3D-CEC-FM includes a new module that simulates energy conversion (momentum withdrawal) by MHK current energy conversion devices with commensurate changes in the turbulent kinetic energy and its dissipation rate. SNL-Delft3D-CEC-FM modified the Delft3D flexible mesh flow solver, DFlowFM. The Following is a description of Deltares’s open-source code Delft3D from which Delft3D-CEC is built upon. “Delft3D is a world leading 3D modeling suite to investigate hydrodynamics, sediment transport and morphology and water quality for fluvial, estuarine and coastal environments. As per 1 January 2011, the Delft3D flow (FLOW), morphology (MOR) and waves (WAVE) modules are available in open source. The software is used and has proven his capabilities on many places around the world, like the Netherlands, USA, Hong Kong, Singapore, Australia, Venice, etc. The software is continuously improved and developed with innovating advanced modelling techniques as consequence of the research work of our institute and to stay world leading. The FLOW module is the heart of Delft3D and is a multi-dimensional (2D or 3D) hydrodynamic (and transport) simulation program which calculates non-steady flow and transport phenomena resulting from tidal and meteorological forcing on a curvilinear, boundary fitted grid or spherical coordinates. In 3D simulations, the vertical grid is defined following the so-called sigma coordinate approach or Z-layer approach. The MOR module computes sediment transport (both suspended and bed total load) and morphological changes for an arbitrary number of cohesive and non-cohesive fractions. Both currents and waves act as driving forces and a wide variety of transport formulae have been incorporated. For the suspended load this module connects to the 2D or 3D advection-diffusion solver of the FLOW module; density effects may be taken into account. An essential feature of the MOR module is the dynamic feedback with the FLOW and WAVE modules, which allow the flows and waves to adjust themselves to the local bathymetry and allows for simulations on any time scale from days (storm impact) to centuries (system dynamics). It can keep track of the bed composition to build up a stratigraphic record. The MOR module may be extended to include extensive features to simulate dredging and dumping scenarios. For over 30 years Deltares has been in the forefront of these types of combined morphological simulation techniques.”

Chartand, Chris↗

Charting a Path for Research and Development of Reliability and Resilience in South Asia's Power Sector

The power sector in South Asia faces several trends with the potential to impact its reliability and resilience. Rapidly increasing demand, coupled with an increasing reliance on variable renewable resources and the circular linkages with climate change points to an increasing need to understand the extent of climate impacts on both the electricity load and the electricity generation. These larger shifts are also coupled with opportunities near the grid edge that could have a large impact on system planning and operations, such as electrification of the transport sector, increased reliance on buildings to serve a broader set of loads and be flexible resources for utilities, more efficient use of industrial and agricultural loads, and growth in distributed energy resources such as rooftop solar and batteries. It is critical that as this transformation takes place that expectations for reliability and resilience of the grid continue to increase in the region. The South Asia Group for Energy (SAGE), composed of USAID, the US Department of Energy, and three national laboratories, has been tasked with providing an overview of the research and development resources necessary to understand the upcoming challenges for the power system as it pertains to reliability and resilience. This discussion paper identifies some of the key trends and connections that are important for power sector reliability and resilience and provides a starting point for eliciting feedback from power sector stakeholders about their experiences and needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Navier-Stokes Simulation of Airconditioning Facility of a Large Modem Computer Room

NASA recently assembled one of the world's fastest operational supercomputers to meet the agency's new high performance computing needs. This large-scale system, named Columbia, consists of 20 interconnected SGI Altix 512-processor systems, for a total of 10,240 Intel Itanium-2 processors. High-fidelity CFD simulations were performed for the NASA Advanced Supercomputing (NAS) computer room at Ames Research Center. The purpose of the simulations was to assess the adequacy of the existing air handling and conditioning system and make recommendations for changes in the design of the system if needed. The simulations were performed with NASA's OVERFLOW-2 CFD code which utilizes overset structured grids. A new set of boundary conditions were developed and added to the flow solver for modeling the roomls air-conditioning and proper cooling of the equipment. Boundary condition parameters for the flow solver are based on cooler CFM (flow rate) ratings and some reasonable assumptions of flow and heat transfer data for the floor and central processing units (CPU) . The geometry modeling from blue prints and grid generation were handled by the NASA Ames software package Chimera Grid Tools (CGT). This geometric model was developed as a CGT-scripted template, which can be easily modified to accommodate any changes in shape and size of the room, locations and dimensions of the CPU racks, disk racks, coolers, power distribution units, and mass-storage system. The compute nodes are grouped in pairs of racks with an aisle in the middle. High-speed connection cables connect the racks with overhead cable trays. The cool air from the cooling units is pumped into the computer room from a sub-floor through perforated floor tiles. The CPU cooling fans draw cool air from the floor tiles, which run along the outside length of each rack, and eject warm air into the center isle between the racks. This warm air is eventually drawn into the cooling units located near the walls of the room. One major concern is that the hot air ejected to the middle isle might recirculate back into the cool rack side and cause thermal short-cycling. The simulations analyzed and addressed the following important elements of the computer room: 1) High-temperature build-up in certain regions of the room; 2) Areas of low air circulation in the room; 3) Potential short-cycling of the computer rack cooling system; 4) Effectiveness of the perforated cooling floor tiles; 5) Effect of changes in various aspects of the cooling units. Detailed flow visualization is performed to show temperature distribution, air-flow streamlines and velocities in the computer room.

Source record↗

A Siamese CNN + KNN-Based Classification Framework for Non-intrusive Load Monitoring

Through the development of smart grids, programs such as demand side response, have been presented as auxiliary services to the real-time operation of distributed networks. In order to provide consumers information on their energy consumption, so that a modulation in consumption is possible, non-intrusive load monitoring has been introduced as an solution to this pattern recognition problem. Non-intrusive load monitoring enables the modeling of electrical loads connected to the low-voltage system, considering only a single measurement point. Presented state-of-the-art solutions though, consider availability of data as well as representation of all possible classes of the environment. This is of course a most conservative hypothesis, since in real-life applications availability of such data is much difficult, as well as the dynamic behavior of models is implicitly evolving in time. Here, a framework that uses neural Siamese networks with k-nearest neighbor clustering is presented toward non-intrusive load monitoring. Online learning feature is implemented, which relaxes the hypothesis of data requirements as well addresses the evolving nature of load profile. k-nearest clustering allows nonlinear characteristic space modelling. Test results using synthetics and real-life data show that the solution, besides obtaining a good generalizability in the classification, also obtained results with an accuracy of 95.77%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of renewable energy generation and storage systems for emissions reduction in an islanded campus microgrid

Microgrid connected building communities are projected to play an integral part in the clean energy transition. These types of systems, when integrated with distributed energy resources (DERs) such as combined heat and power (CHP), district heating and cooling, renewable generation, and energy storage, can provide clean, reliable power to critical facilities and vulnerable communities. The intermittent nature of renewable generation is a challenge when integrating renewables into any grid system, but particularly in islanded microgrids. The University of Texas at Austin (UT) operates an islanded microgrid powered by a CHP plant, while also utilizing district heating and cooling systems and thermal energy storage (TES). High fidelity operating data was used to develop a validated reduced order model of UT’s integrated campus energy systems to serve as a testbed for use in a case study. Hypothetical renewable energy installations on land owned by UT in west Texas were modeled and integrated into the validated campus models along with battery energy storage (BES). Simulations showed that a combination of renewable energy from wind, and optimally controlled 24-hour thermal and battery storage systems could reduce carbon dioxide emissions on campus by 45.4%. The additional retrofit of burner systems to utilize hydrogen natural gas blends resulted in an overall annual emissions reduction of 54.7%. Carbon capture and storage eliminated the majority of the remaining emissions with increased plant energy expenditure. The presented simulations display the practical limitations of a CHP system complemented by renewable generation and short-term storage in eliminating emissions. Furthermore, results highlight the need for further research and development in long duration storage technologies and hydrogen fueled turbines to increase penetration of renewable energy and reduce emissions.

CHP↗

Control voltage and power fluctuations when connecting wind farms

Voltage, frequency, active power and reactive power are very important parameters in terms of power quality. These parameters are followed when connecting any power plant, the more the connection of wind farms. Connecting wind farms to the electricity system must not cause interference outside the limits set by regulations. Modern solutions for fast and automatic voltage control and power fluctuations using electronic control systems of reactive power flows. FACTS (Flexible Alternating Current Transmision System) systems, established on the basis of power electronic circuits ensure control of electrical status quantities to achieve the necessary transfer of power to the power grid. FACTS devices can quickly control parameters and sizes of state power lines, such as impedance line voltages and phase angles of the voltages of the two ends of the line. Their use can lead to improvement in power system operation by increasing the transmission capacity of power lines, power flow control lines, improved static and transient stability reserve.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NASA's Unsteady Pressure-Sensitive Paint Research and Operational Capability Developments

In the last three years, several advancements have been made to produce a new state-of-the-art capability in the field of Aerosciences. NASA’s Aerosciences Evaluations and Test Capabilities (AETC) Portfolio Office has funded a multi-year project to produce the unsteady Pressure-Sensitive Paint (uPSP) technology as an operational capability in key ground test facilities at NASA. The research and development has primarily been conducted at NASA Ames Research Center’s (ARC) Unitary Plan Wind Tunnel (UPWT) 11-by 11-ft Transonic Wind Tunnel (TWT). The NASA ARC UPWT is one of the ground test facilities under NASA AETC’s Portfolio Office. AETC’s goals are to provide the tools to deliver the technology innovations and breakthroughs necessary to address increasingly complex research and development challenges. AETC’s integrated approach will consider the complimentary high-end compute capabilities necessary to advance analysis in conjunction with ground experimental capabilities. The uPSP Capability Challenge Project is a demonstration of several different technologies: 1) the unsteady Pressure-Sensitive Paint (uPSP) technology, and 2) Project: Red Rover, establishing a secure, reliable, fast connection between experimental and computation facilities, leveraging NASA’s computational resources within the High-End Compute Capability (HECC) Project for processing, storing, and sharing data efficiently. This project demonstrates the technical diversity and technical inclusion need to advance the field of Aerosciences. The approach to combine subject matter experts in experimental methods, optical methods, production wind tunnel testing, network engineering, high-end computing, signal processing, grid generation, and visualization while establishing the required infrastructure for subject matter experts to have access to the data while the wind tunnel test is being conducted. The most recent advancements for the uPSP technology have focused on three key areas: development of data products, robust processing pipeline, operational efficiencies and uncertainty quantification.

buffet↗