Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image analysis.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Localized Strain Analysis of Ce- and Mg-Treated Cast Iron under Uniaxial Compression

Cast iron exhibits a wide range of mechanical properties, depending on its microstructural features. The microstructure of cast iron consists of several microconstituents with different elastic-plastic behavior, making the strain non-uniform across the bulk material. To understand the individual effects of these microconstituents on the overall mechanical behavior, local strain analysis using digital image correlation analysis was carried out. Samples with two different compositions (varying cerium, magnesium and silicon) were processed at different solidification velocities in a Bridgman furnace. Sections of the directionally solidified samples were loaded under uniaxial compression to measure global and local strain behavior. Despite the variability of the microstructure, the stress–strain curves obtained by digital image correlation (DIC) were found to react in a well-controlled way to changes in solidification velocity. It was observed that high-strain failure (greater than 15%) was accompanied by local straining of the softer ferritic phase, but during low-strain failure, local straining was not prominent. Higher nodularities, due to higher solidification velocities, raised the compressive strength without affecting the toughness significantly. Higher percentages of carbides led to higher compressive strengths with corresponding losses in ductility. The continuity of the matrix was also found to play an important role in the behavior during compression.

ductile failure↗

Image Guider Subsystem Analysis for the GHAPS Project

The Gondola for High-Altitude Planetary Science (GHAPS) project is a balloon-borne astronomical observatory designed operate in the UV, Visible, and near-mid IR spectral region. The GHAPS Optical Telescope Assembly (OTA) is designed around a one meter aperture narrow field-of-view telescope with near-diffraction-limited performance. GHAPS will utilize Wallops Arc-Second Pointing System (WASP) for pointing the OTA with an accuracy of 1 arc second or better. WASP relies heavily on a self-contained star tracker assembly to determine the OTA line of sight. Preliminary structural analysis indicates that potential misalignments could be present between the OTA line of sight and the star tracker FOV center during the expected flight conditions that could compromise GHAPS pointing accuracy. In response the GHAPS project undertook a trade study to resolve the following issues: (1) estimate the worst case long-term (or bias) pointing misalignments for the GHAPS opto-mechanical configuration, (2) examine the need for additional hardware to correct pointing errors, and (3) determine the best hardware and software implementation to do so. Quantitative comparisons of performance and qualitative estimates of other factors such as mass, volume, power consumption, and cost are combined into an overall assessment of potential solutions. Results are discussed and a recommended implementation is given that is optimized to best achieve pointing performance goals, while minimizing impact to the design, cost, and resources of the GHAPS project.

Star Tracker↗

Imaging and structure analysis of ferroelectric domains, domain walls, and vortices by scanning electron diffraction

Direct electron detectors in scanning transmission electron microscopy give unprecedented possibilities for structure analysis at the nanoscale. In electronic and quantum materials, this new capability gives access to, for example, emergent chiral structures and symmetry-breaking distortions that underpin functional properties. Quantifying nanoscale structural features with statistical significance, however, is complicated by the subtleties of dynamic diffraction and coexisting contrast mechanisms, which often results in a low signal-to-noise ratio and the superposition of multiple signals that are challenging to deconvolute. Here we apply scanning electron diffraction to explore local polar distortions in the uniaxial ferroelectric Er(Mn,Ti)O 3 . Using a custom-designed convolutional autoencoder with bespoke regularization, we demonstrate that subtle variations in the scattering signatures of ferroelectric domains, domain walls, and vortex textures can readily be disentangled with statistical significance and separated from extrinsic contributions due to, e.g., variations in specimen thickness or bending. The work demonstrates a pathway to quantitatively measure symmetry-breaking distortions across large areas, mapping structural changes at interfaces and topological structures with nanoscale spatial resolution.

36 MATERIALS SCIENCE↗

Exploring thermal runaway propagation in Li-ion batteries through high-speed X-ray imaging and thermal analysis: Impact of cell chemistry and electrical connections

Battery safety design is important to consider from the individual Li-ion cell to the level of the macro-system. On the macro-level, failure in one single cell can lead to propagation of the thermal runaway and rapidly set a whole battery pack on fire. Factors that can impact the propagation outcome, such as cell model/chemistry and electrical connection are here investigated using a combination of measurements. Several abusive tests were conducted, combining two different cell models (Molicel P42A and LG M50, both 21700s) in series and parallel connections (16 tests per configuration). Overall, a propagation outcome of 56% was measured from the 32 conducted tests, a minimum temperature of 150 °C was required to initiate propagation, and the fastest propagation occurred in 123 s. Temperature measurements were higher in series connected cells, initiating the discussion of cell chemistry and internal resistance on this effect. The difference in current-flow during thermal runaway in series and parallel connections, and how this can affect the temperature evolution is further discussed. Spatio-temporal mapping of X-ray radiography allowed us to derive the speed of thermal runaway evolution inside the battery and has shown that series connected cells, in particular P42A, occur faster. It was further observed that deviant sidewall behaviors such as temperature-induced breaches and pressure-induced ruptures occurred in P42As only respective nail-penetrated cells only.

25 ENERGY STORAGE↗

AI Model Benchmarking for Nonproliferation Applications: Steel Thread Benchmarking Task Force Technical Report (Rev. 2)

Steel Thread is a NA-22 venture that seeks to build trustworthy, reliable AI models that can be used in a wide variety of nonproliferation tasks. A key aspect of building these models is developing appropriate benchmarks and evaluation methods, which will enable the venture to identify and adapt models to provide the most value in the nonproliferation domain. Benchmarks must be relevant to key tasks in this domain, such as question answering, information retrieval, document summarization and classification, consensus analysis, and image and data analysis. This report 1) provides an overview of benchmark design, evaluation, and challenges; 2) reviews a variety of open benchmarks, with a focus on language models and tasks; and 3) identifies benchmarks that are most relevant to Steel Thread. This report is intended to serve as a basis for further efforts to classify and evaluate benchmarks and their correlation with success on nonproliferation-specific tasks. The Steel Thread venture has defined benchmarks to be a particular combination of a dataset (or datasets) and a metric (or metrics) conceptualized as representing one or more specific tasks or sets of abilities for a specific modality. It is adopted by a research community as a shared framework for comparing methods.1 It includes 1) Data: Labeled (a designated subset not used for training, which could be all the data), 2) Metric: A way to quantify performance, 3) Task/Ability: What the benchmark is testing, 4) Protocol: A structured and repeatable evaluation process, 5) Baseline/Reference Model: For comparison; could be statistical, rule-based, SME-derived, or another model, and 6) Maintenance Plan: to update with new information over time; important for long-term utility. For further clarity, the definition includes what a benchmark, in this context, is not. It is not a corpus of training data, specific to a model (it is intended to apply to a range of models), a universal evaluation of performance, a guarantee that the ‘top’ model on the leaderboard will be the best fit for every specific use case, an all-encompassing proof of a model’s universal quality, nor is it a one-size-fits-all measure of success. It does not cover every real-world constraint (like operational, ethical, or cost considerations), a systems integration test, or a unit test. This definition was inspired by and resulted from discussions within the Steel Thread Benchmarking Task Force. This group was formed to define what we would mean as a benchmark within Steel Thread but persisted as the need to develop a thorough understanding of the large and expanding existing benchmarking space. This technical report is a result of the group’s divide and conquer approach to exploring this space. The release of benchmarks might not be progressing as quickly as model development, but it is moving very fast, as many benchmarks quickly become saturated, when state-of-the-art models score so close to the benchmark’s ceiling that their results are virtually indistinguishable. At that point, the test no longer differentiates between new systems, so researchers usually stop reporting scores as the benchmark no longer informs about improvements from the next generation of models. In the OpenAI announcement of GPT-5, they reported results on six flagship public benchmarks (AIME 2025, SWE-bench Verified, Aider Polyglot, MMMU, HealthBench Hard, GPQA) but the full system-card covers roughly thirty-five separate evaluations, comprising hundreds of test task items in total. There have been some efforts to summarize benchmarks in specific fields, like for text-to-image generation, but these surveys have had a narrow methodology scope. Therefore, a comprehensive survey of all benchmarks or even all benchmarks that could be relevant to Steel Thread is outside of the scope of this report. We chose some specific benchmarks to investigate in detail.

97 MATHEMATICS AND COMPUTING↗

Characterization of red mud-epoxy intumescent char using surface imaging and micro analysis

In this study, red mud (RM), an oxide waste was proposed as reinforcing, synergistic filler for the traditional epoxy intumescent coating (IC). 5.5 wt% of acid-modified and unmodified red mud were introduced into the basic intumescent formulation of ammonium polyphosphate (APP), pentaerythritol (PER) and melamine (MEL). In order to predict effect of modification on its suitability, Field emission electron scanning microscopy and Fourier transform infra red were used to obtain detailed characteristics such as the cell size, pore distribution, homogeneity and chemical composition of the red mud-epoxy carbonaceous char. Both acid-modified and unmodified RM-filled ICs produced chars with smaller and more closely packed cells compared to chars from the unfilled coating. Both coating types had hard carbonaceous metal phosphate coverings that could act as heat barriers. The unmodified red mud was found to be antagonistic to the intumescent action with an expansion of only 2 times the initial thickness. The leached, low iron-red mud produced an expansion of 15 times the initial thickness, but possessed a hollow interior. From these findings, it may be deduced that while acid leaching of red mud may improve intumescent expansion, it would be necessary to optimize the percent filler loading to improve residual mass.

36 MATERIALS SCIENCE↗

Online quantitative analysis of multispectral images of human body tissues

A method is developed for online monitoring of structural and morphological parameters of biological tissues (haemoglobin concentration, degree of blood oxygenation, average diameter of capillaries and the parameter characterising the average size of tissue scatterers), which involves multispectral tissue imaging, image normalisation to one of its spectral layers and determination of unknown parameters based on their stable regression relation with the spectral characteristics of the normalised image. Regression is obtained by simulating numerically the diffuse reflectance spectrum of the tissue by the Monte Carlo method at a wide variation of model parameters. The correctness of the model calculations is confirmed by the good agreement with the experimental data. The error of the method is estimated under conditions of general variability of structural and morphological parameters of the tissue. The method developed is compared with the traditional methods of interpretation of multispectral images of biological tissues, based on the solution of the inverse problem for each pixel of the image in the approximation of different analytical models. (biomedical optics)

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analysis of contour images using optics of spiral beams

An approach is outlined to the recognition of contour images using computer technology based on coherent optics principles. A mathematical description of the recognition process algorithm and the results of numerical modelling are presented. The developed approach to the recognition of contour images using optics of spiral beams is described and justified. (image recognition)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

HUBBLE SPACE TELESCOPE IMAGING AND SPECTRAL ANALYSIS OF TWO BROWN DWARF BINARIES AT THE L DWARF/T DWARF TRANSITION

We present a detailed examination of the brown dwarf multiples 2MASS J08503593+1057156 and 2MASS J17281150+3948593, both suspected of harboring components that straddle the L dwarf/T dwarf transition. Resolved photometry from Hubble Space Telescope/NICMOS shows opposite trends in the relative colors of the components, with the secondary of 2MASS J0850+1057 being redder than its primary, while that of 2MASS J1728+3948 is bluer. We determine near-infrared component types by matching combined-light, near-infrared spectral data to binary templates, with component spectra scaled to resolved NICMOS and K{sub p} photometry. Combinations of L7 + L6 for 2MASS J0850+1057 and L5 + L6.5 for 2MASS J1728+3948 are inferred. Remarkably, the primary of 2MASS J0850+1057 appears to have a later-type classification compared to its secondary, despite being 0.8-1.2 mag brighter in the near-infrared, while the primary of 2MASS J1728+3948 is unusually early for its combined-light optical classification. Comparison to absolute magnitude/spectral type trends also distinguishes these components, with 2MASS J0850+1057A being {approx}1 mag brighter and 2MASS J1728+3948A {approx} 0.5 mag fainter than equivalently classified field counterparts. We deduce that thick condensate clouds are likely responsible for the unusual properties of 2MASS J1728+3948A, while 2MASS J0850+1057A is either an inflated young brown dwarf or a tight unresolved binary, making it potentially part of a wide, low-mass, hierarchical quintuple system.

79 ASTRONOMY AND ASTROPHYSICS↗

Shapes of rotating superfluid helium nanodroplets

Rotating superfluid He droplets of approximately 1 μm in diameter were obtained in a free nozzle beam expansion of liquid He in vacuum and were studied by single-shot coherent diffractive imaging using an x-ray free electron laser. The formation of strongly deformed droplets is evidenced by large anisotropies and intensity anomalies (streaks) in the obtained diffraction images. The analysis of the images shows that in addition to previously described axially symmetric oblate shapes, some droplets exhibit prolate shapes. Forward modeling of the diffraction images indicates that the shapes of rotating superfluid droplets are very similar to their classical counterparts, giving direct access to the droplet angular momenta and angular velocities. Here, the analyses of the radial intensity distribution and appearance statistics of the anisotropic images confirm the existence of oblate metastable superfluid droplets with large angular momenta beyond the classical bifurcation threshold.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of a Fluorochlorozirconate Glass-Ceramic Storage Phosphor Plate for Gamma-Ray Computed Radiography

In this paper, a fluorochlorozirconate (FCZ) glass-ceramic containing orthorhombic barium chloride crystals doped with divalent europium was evaluated for use as a storage phosphor in gamma-ray imaging. X-ray diffraction and phosphorimetry of the glass-ceramic sample showed the presence of a significant amount of orthorhombic barium chloride crystals in the glass matrix. Transmission electron microscopy and scanning electron microscopy were used to identify crystal size, structure, and morphology. The size of the orthorhombic barium chloride crystals in the FCZ glass matrix was very large, ~0.5–0.7 μm, which can limit image resolution. The FCZ glass-ceramic sample was exposed to 1 MeV gamma rays to determine its photostimulated emission characteristics at high energies, which were found to be suitable for imaging applications. Test images were made at 2 MeV energies using gap and step wedge phantoms. Gaps as small as 101.6 μm in a 440 stainless steel phantom were imaged using the sample imaging plate. Analysis of an image created using a depleted uranium step wedge phantom showed that emission is proportional to incident energy at the sample and the estimated absorbed dose. Finally, the results showed that the sample imaging plate has potential for gamma-ray-computed radiography and dosimetry applications.

36 MATERIALS SCIENCE↗

Analysis of deformable image registration accuracy using computational modeling

Computer aided modeling of anatomic deformation, allowing various techniques and protocols in radiation therapy to be systematically verified and studied, has become increasingly attractive. In this study the potential issues in deformable image registration (DIR) were analyzed based on two numerical phantoms: One, a synthesized, low intensity gradient prostate image, and the other a lung patient's CT image data set. Each phantom was modeled with region-specific material parameters with its deformation solved using a finite element method. The resultant displacements were used to construct a benchmark to quantify the displacement errors of the Demons and B-Spline-based registrations. The results show that the accuracy of these registration algorithms depends on the chosen parameters, the selection of which is closely associated with the intensity gradients of the underlying images. For the Demons algorithm, both single resolution (SR) and multiresolution (MR) registrations required approximately 300 iterations to reach an accuracy of 1.4 mm mean error in the lung patient's CT image (and 0.7 mm mean error averaged in the lung only). For the low gradient prostate phantom, these algorithms (both SR and MR) required at least 1600 iterations to reduce their mean errors to 2 mm. For the B-Spline algorithms, best performance (mean errors of 1.9 mm for SR and 1.6 mm for MR, respectively) on the low gradient prostate was achieved using five grid nodes in each direction. Adding more grid nodes resulted in larger errors. For the lung patient's CT data set, the B-Spline registrations required ten grid nodes in each direction for highest accuracy (1.4 mm for SR and 1.5 mm for MR). The numbers of iterations or grid nodes required for optimal registrations depended on the intensity gradients of the underlying images. In summary, the performance of the Demons and B-Spline registrations have been quantitatively evaluated using numerical phantoms. The results show that parameter selection for optimal accuracy is closely related to the intensity gradients of the underlying images. Also, the result that the DIR algorithms produce much lower errors in heterogeneous lung regions relative to homogeneous (low intensity gradient) regions, suggests that feature-based evaluation of deformable image registration accuracy must be viewed cautiously.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-159: Analysis of Total Imaging Uncertainty in Respiratory-Gated Radiotherapy

Purpose: In respiratory-gated radiotherapy, the gating phase during treatment delivery needs to coincide with the corresponding phase determined during the treatment plan. However, because radiotherapy is performed based on the image obtained for the treatment plan, the time delay, motion artifact, volume effect, and resolution in the images are uncertain. Thus, imaging uncertainty is the most basic factor that affects the localization accuracy. Therefore, these uncertainties should be analyzed. This study aims to analyze the total imaging uncertainty in respiratory-gated radiotherapy. Methods: Two factors of imaging uncertainties related to respiratory-gated radiotherapy were analyzed. First, CT image was used to determine the target volume and 4D treatment planning for the Varian Realtime Position Management (RPM) system. Second, an X-ray image was acquired for image-guided radiotherapy (IGRT) for the BrainLAB ExacTrac system. These factors were measured using a respiratory gating phantom. The conditions applied during phantom operation were as follows: respiratory wave form, sine curve; respiratory cycle, 4 s; phantom target motion amplitude, 10, 20, and 29 mm (which is maximum phantom longitudinal motion). The target and cylindrical marker implanted in the phantom coverage of the CT images was measured and compared with the theoretically calculated coverage from the phantom motion. The theoretical position of the cylindrical marker implanted in the phantom was compared with that acquired from the X-ray image. The total imaging uncertainty was analyzed from these two factors. Results: In the CT image, the uncertainty between the target and cylindrical marker’s actual coverage and the coverage of CT images was 1.19 mm and 2.50mm, respectively. In the Xray image, the uncertainty was 0.39 mm. The total imaging uncertainty from the two factors was 1.62mm. Conclusion: The total imaging uncertainty in respiratory-gated radiotherapy was clinically acceptable. However, an internal margin should be added to account for the total imaging uncertainty.

60 APPLIED LIFE SCIENCES↗

SU-F-BRB-01: How Effective Is Abdominal Compression at Reducing Lung Motion? An Analysis Using Deformable Image Registration Within Different Sub-Regions of the Lung

Purpose: To investigate the effectiveness of employing abdominal compression (AC) in reducing motion for the target region and sub-regions of the lung as part of the planning process for radiation therapy. Methods: Fourteen patients with early lung cancer were scanned with 4DCT and it was determined that target motion exceeded our institutional limit of > 8 mm motion and received a repeat 4DCT with AC. For each 4DCT, deformable image registration (DIR) was used to map the max inhale to the max exhale phase to determine the deformation vector fields (DVF). DIR was performed with Morphons and Demons algorithms. The mean DVF was used to represent that sub-region for each patient. The magnitudes of the mean DVF were quantified for the target and 12 sub-regions in the AP, LR SI directions. The sub-regions were contoured on each lung as (add prefix R or L for lung): Upper-Anterior (UA), Upper-Posterior (UP), Mid-Anterior (MA), Mid-Posterior (MP), Lower-Anterior (LA) and Lower-Posterior (LP). Results: The min/max SI motion for the target on the uncompressed 4DCT was 8mm/24.5 mm. The magnitude of decrease in SI was greatest in the RLP region (3.7±4.0mm) followed by target region (3.3±2.2mm) and finally the LLP region (3.0±3.5mm). The magnitude of decrease in 3D vector followed the same trend; RLP (3.5±2.2mm) then GTV (3.5±2.6mm) then LLP (2.7±3.8mm). 79% of the cases had a SI decrease of >12.5%, 43% had a SI decrease of >25% and 21% had a SI decrease of >50% as compared to the motion on the uncompressed 4DCT. Conclusion: AC is useful in reducing motion with the largest decreases observed in the lower posterior regions of the lungs. However, it should be noted that AC will not greatly decrease motion for all cases as 21% of cases did not reduce SI motion more than 12.5% of initial motion.

60 APPLIED LIFE SCIENCES↗