Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image processing.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Machine vision for real time orbital operations

Machine vision for automation and robotic operation of Space Station era systems has the potential for increasing the efficiency of orbital servicing, repair, assembly and docking tasks. A machine vision research project is described in which a TV camera is used for inputing visual data to a computer so that image processing may be achieved for real time control of these orbital operations. A technique has resulted from this research which reduces computer memory requirements and greatly increases typical computational speed such that it has the potential for development into a real time orbital machine vision system. This technique is called AI BOSS (Analysis of Images by Box Scan and Syntax).

Vinz, Frank L.↗

Dispersed Fringe Sensing Analysis - DFSA

Dispersed Fringe Sensing (DFS) is a technique for measuring and phasing segmented telescope mirrors using a dispersed broadband light image. DFS is capable of breaking the monochromatic light ambiguity, measuring absolute piston errors between segments of large segmented primary mirrors to tens of nanometers accuracy over a range of 100 micrometers or more. The DFSA software tool analyzes DFS images to extract DFS encoded segment piston errors, which can be used to measure piston distances between primary mirror segments of ground and space telescopes. This information is necessary to control mirror segments to establish a smooth, continuous primary figure needed to achieve high optical quality. The DFSA tool is versatile, allowing precise piston measurements from a variety of different optical configurations. DFSA technology may be used for measuring wavefront pistons from sub-apertures defined by adjacent segments (such as Keck Telescope), or from separated sub-apertures used for testing large optical systems (such as sub-aperture wavefront testing for large primary mirrors using auto-collimating flats). An experimental demonstration of the coarse-phasing technology with verification of DFSA was performed at the Keck Telescope. DFSA includes image processing, wavelength and source spectral calibration, fringe extraction line determination, dispersed fringe analysis, and wavefront piston sign determination. The code is robust against internal optical system aberrations and against spectral variations of the source. In addition to the DFSA tool, the software package contains a simple but sophisticated MATLAB model to generate dispersed fringe images of optical system configurations in order to quickly estimate the coarse phasing performance given the optical and operational design requirements. Combining MATLAB (a high-level language and interactive environment developed by MathWorks), MACOS (JPL s software package for Modeling and Analysis for Controlled Optical Systems), and DFSA provides a unique optical development, modeling and analysis package to study current and future approaches to coarse phasing controlled segmented optical systems.

Sigrist, Norbert↗

Precision Pointing Improvements for the Lunar Reconnaissance Orbiter Camera

The Lunar Reconnaissance Orbiter (LRO) was launched in 2009 and, with its seven science instruments, continues to make remarkable discoveries of the Moon. LRO is in a slightly elliptical, polar lunar orbit and nominally maintains a nadir orientation. In early 2018, the Miniature Inertial Measurement Unit (MIMU) was powered off following a fairly rapid decline in the laser intensity on the X axis. An algorithm combining star tracker quaternion differentiated rates and integrated control torque commands in a complementary filter, now provides the onboard rate estimate, replacing the MIMU. One of the science instruments, the LRO Camera(LROC) system, contains a Wide Angle Camera (WAC) and two Narrow Angle Cameras (NAC). The NACs suffer from larger attitude drifts during imaging of the Moon for stereo image processing, resulting from pointing stability degradation of the star tracker derived rates. The controller gains and structural filter were redesigned to attenuate the new disturbances while also maintaining adequate stability and modal suppression. This paper documents the development, testing, and operational implementation of the revised control system parameters, specifically targeted for use during LROC imaging. The new parameters improved pointing performance for LROC.

Julie Halverson↗

Automatic terrain elevation mapping and registration

Optimum radar illumination geometries for stereoscopic analysis of surface topography are determined. Correlation and image processing experiments on synthetic aperture radar (SAR) data for improved information extraction are conducted. Model of the geometry of the multiple SIR-B views of the Earth are developed the sensitivity of the derived terrain altitude data to the various system parameters is established. The limits of accuracy of terrain data achievable with shuttle imaging radar (SIR-B) are derived. Algorithms for matching multiple SIR-B images to generate digital terrain maps are developed. Finally, the use of such terrain maps in geometric correction and registration of SIR-B and LANDSAT Thematic Mapper data is demonstrated.

Ramapriyan, H. K.↗

Low cost, microcomputer-based interactive analysis system for direct-reception and archived remote sensing data

A hardware/software system has been developed for use in meteorological field experiments and by developing countries which need low-cost remote sensing data analysis capabilities. The system can directly receive satellite transmissions of the AVHRR, TOVS, Argos, GOES, GMS, and Meteosat systems. Also, the system can process computer tapes from Landsat. Received data are ingested directly into the computer's disk storage, eliminating the need for a wide-band analog tape drive. Data may be interpreted in terms of cloud imagery, cloudtop temperature, sea surface temperature, vegetation index, and temperature/humidity profiles with overlays of geographic boundaries and latitude/longitude grids. The image processing, enhancement functions, and modeling capabilities of the system are discussed.

Vermillion, Charles H.↗

Milli-Arcsecond (MAS) Imaging with SmallSat Enabled Super-resolution

The objective of this project is to demonstrate a new imaging technology with unprecedented capabilities for scientific exploration. This technology innovation will enable extremely high-resolution imaging capability, otherwise unattainable with conventional approaches. It is based on a unique combination of novel diffractive optical sensing (photon sieve), advanced image processing, and small satellite formation flying. The spatial resolution of current solar instruments are more than 100 times coarser than the size of energy dissipation features in coronal heating (<100 km) since conventional optics cannot be figured to near diffraction-limited accuracy at extreme ultraviolet (EUV) wavelengths. This project will demonstrate the feasibility of imaging of a few milli-arcseconds (MAS) to study the structure and development of these dissipation regions.

Farzad Kamalabadi↗

A Noncontact Measurement Technique for the Density and Thermal Expansion Coefficient of Solid and Liquid Materials

A noncontact measurement technique for the density and the thermal expansion refractory materials in their molten as well as solid phases is presented. This technique is based on the video image processing of a levitated sample. Experiments were performed using the high-temperature electrostatic levitator (HTESL) at the Jet Propulsion Laboratory in which 2-3 mm diameter samples can be levitated, melted, and radiatively cooled in a vacuum. Due to the axisymmetric nature of the molten samples when levitated in the HTESL, a rather simple digital image analysis can be employed to accurately measure the volumetric change as a function of temperature. Density and the thermal expansion coefficient measurements were made on a pure nickel sample to test the accuracy of the technique in the temperature range of 1045-1565 C. The result for the liquid phase density can be expressed by p = 8.848 + (6.730 x 10(exp -4)) x T (degC) g/cu cm within 0.8% accuracy, and the corresponding thermal expansion coefficient can be expressed by Beta=(9.419 x 10(exp -5)) - (7.165 x 10(exp -9) x T (degC)/K within 0.2% accuracy.

Chung, Sang K.↗

Improvements for Image Compression Using Adaptive Principal Component Extraction (APEX)

The issues of image compression and pattern classification have been a primary focus of researchers among a variety of fields including signal and image processing, pattern recognition, data classification, etc. These issues depend on finding an efficient representation of the source data. In this paper we collate our earlier results where we introduced the application of the. Hilbe.rt scan to a principal component algorithm (PCA) with Adaptive Principal Component Extraction (APEX) neural network model. We apply these technique to medical imaging, particularly image representation and compression. We apply the Hilbert scan to the APEX algorithm to improve results

Ziyad, Nigel A.↗

Low Latency DESDynI Data Products for Disaster Response, Resource Management and Other Applications

We are developing onboard processor technology targeted at the L-band SAR instrument onboard the planned DESDynI mission to enable formation of SAR images onboard opening possibilities for near-real-time data products to augment full data streams. Several image processing and/or interpretation techniques are being explored as possible direct-broadcast products for use by agencies in need of low-latency data, responsible for disaster mitigation and assessment, resource management, agricultural development, shipping, etc. Data collected through UAVSAR (L-band) serves as surrogate to the future DESDynI instrument. We have explored surface water extent as a tool for flooding response, and disturbance images on polarimetric backscatter of repeat pass imagery potentially useful for structural collapse (earthquake), mud/land/debris-slides etc. We have also explored building vegetation and snow/ice classifiers, via support vector machines utilizing quad-pol backscatter, cross-pol phase, and a number of derivatives (radar vegetation index, dielectric estimates, etc.). We share our qualitative and quantitative results thus far.

applications↗

Bubble-Size Evolution during Polyurethane Foam Expansion

We are developing computational models to elucidate the expansion and dynamic filling process of a polyurethane (PMDI) foam used to encapsulate electronic components or to produce lightweight structural parts. The polyurethane of interest is a chemically blown foam, where carbon dioxide is produced via the reaction of water, a blowing agent, and isocyanate. Here, we take a careful look at the evolution of the bubble sizes during blowing. This information will help the development of subgrid models to predict bubble formation, growth, coalescence and collapse, drainage, and, hence, eventually the development of engineering models to predict foam expansion into a mold. Close-up views of bubbles at a transparent wall of a narrow, temperature-controlled channel are recorded during the foaming reaction and analyzed with image processing. Because these bubbles are pressed against the wall, the bubble sizes in the last frames after the expansion has stopped are compared to scanning electron microscope (SEM) images of the interior of some of the cured samples to determine if the presence of the wall significantly changes the bubble sizes. In addition, diffusing wave spectroscopy (DWS) is used to determine the average bubble sizes across the width of a similar channel as the bubbles change with time. DWS also gives information about microstructural changes as bubbles rearrange upon bubble collapse or coalescence. In this paper we conclude qualitatively that the bubble size distribution is heavily dependent on the formulation of foam being tested, temperature, the height in the foam bar, the proximity to a wall, and the degree of over-packing.

36 MATERIALS SCIENCE↗

MO-B-201-00: Motion Management in Current Stereotactic Body Radiation Therapy (SBRT) Practice

The motion management in stereotactic body radiation therapy (SBRT) is a key to success for a SBRT program, and still an on-going challenging task. A major factor is that moving structures behave differently than standing structures when examined by imaging modalities, and thus require special considerations and employments. Understanding the motion effects to these different imaging processes is a prerequisite for a decent motion management program. The commonly used motion control techniques to physically restrict tumor motion, if adopted correctly, effectively increase the conformity and accuracy of hypofractionated treatment. The effective application of such requires one to understand the mechanics of the application and the related physiology especially related to respiration. The image-guided radiation beam control, or tumor tracking, further realized the endeavor for precision-targeting. During tumor tracking, the respiratory motion is often constantly monitored by non-ionizing beam sources using the body surface as its surrogate. This then has to synchronize with the actual internal tumor motion. The latter is often accomplished by stereo X-ray imaging or similar techniques. With these advanced technologies, one may drastically reduce the treated volume and increase the clinicians’ confidence for a high fractional ablative radiation dose. However, the challenges in implementing the motion management may not be trivial and is dependent on each clinic case. This session of presentations is intended to provide an overview of the current techniques used in managing the tumor motion in SBRT, specifically for routine lung SBRT, proton based treatments, and newly-developed MR guided RT. Learning Objectives: Through this presentation, the audience will understand basic roles of commonly used imaging modalities for lung cancer studies; familiarize the major advantages and limitations of each discussed motion control methods; familiarize the major advantages and limitations of each discussed radiation beam control methodology and tumor tacking method; understand the key points in motion management for a high quality SBRT program.

60 APPLIED LIFE SCIENCES↗

MO-B-201-01: Overcoming the Challenges of Motion Management in Current Lung SBRT Practice

The motion management in stereotactic body radiation therapy (SBRT) is a key to success for a SBRT program, and still an on-going challenging task. A major factor is that moving structures behave differently than standing structures when examined by imaging modalities, and thus require special considerations and employments. Understanding the motion effects to these different imaging processes is a prerequisite for a decent motion management program. The commonly used motion control techniques to physically restrict tumor motion, if adopted correctly, effectively increase the conformity and accuracy of hypofractionated treatment. The effective application of such requires one to understand the mechanics of the application and the related physiology especially related to respiration. The image-guided radiation beam control, or tumor tracking, further realized the endeavor for precision-targeting. During tumor tracking, the respiratory motion is often constantly monitored by non-ionizing beam sources using the body surface as its surrogate. This then has to synchronize with the actual internal tumor motion. The latter is often accomplished by stereo X-ray imaging or similar techniques. With these advanced technologies, one may drastically reduce the treated volume and increase the clinicians’ confidence for a high fractional ablative radiation dose. However, the challenges in implementing the motion management may not be trivial and is dependent on each clinic case. This session of presentations is intended to provide an overview of the current techniques used in managing the tumor motion in SBRT, specifically for routine lung SBRT, proton based treatments, and newly-developed MR guided RT. Learning Objectives: Through this presentation, the audience will understand basic roles of commonly used imaging modalities for lung cancer studies; familiarize the major advantages and limitations of each discussed motion control methods; familiarize the major advantages and limitations of each discussed radiation beam control methodology and tumor tacking method; understand the key points in motion management for a high quality SBRT program.

60 APPLIED LIFE SCIENCES↗

MO-B-201-02: Motion Management for Proton Lung SBR

The motion management in stereotactic body radiation therapy (SBRT) is a key to success for a SBRT program, and still an on-going challenging task. A major factor is that moving structures behave differently than standing structures when examined by imaging modalities, and thus require special considerations and employments. Understanding the motion effects to these different imaging processes is a prerequisite for a decent motion management program. The commonly used motion control techniques to physically restrict tumor motion, if adopted correctly, effectively increase the conformity and accuracy of hypofractionated treatment. The effective application of such requires one to understand the mechanics of the application and the related physiology especially related to respiration. The image-guided radiation beam control, or tumor tracking, further realized the endeavor for precision-targeting. During tumor tracking, the respiratory motion is often constantly monitored by non-ionizing beam sources using the body surface as its surrogate. This then has to synchronize with the actual internal tumor motion. The latter is often accomplished by stereo X-ray imaging or similar techniques. With these advanced technologies, one may drastically reduce the treated volume and increase the clinicians’ confidence for a high fractional ablative radiation dose. However, the challenges in implementing the motion management may not be trivial and is dependent on each clinic case. This session of presentations is intended to provide an overview of the current techniques used in managing the tumor motion in SBRT, specifically for routine lung SBRT, proton based treatments, and newly-developed MR guided RT. Learning Objectives: Through this presentation, the audience will understand basic roles of commonly used imaging modalities for lung cancer studies; familiarize the major advantages and limitations of each discussed motion control methods; familiarize the major advantages and limitations of each discussed radiation beam control methodology and tumor tacking method; understand the key points in motion management for a high quality SBRT program.

60 APPLIED LIFE SCIENCES↗

MO-B-201-03: MRI-Guided Tracking and Gating

The motion management in stereotactic body radiation therapy (SBRT) is a key to success for a SBRT program, and still an on-going challenging task. A major factor is that moving structures behave differently than standing structures when examined by imaging modalities, and thus require special considerations and employments. Understanding the motion effects to these different imaging processes is a prerequisite for a decent motion management program. The commonly used motion control techniques to physically restrict tumor motion, if adopted correctly, effectively increase the conformity and accuracy of hypofractionated treatment. The effective application of such requires one to understand the mechanics of the application and the related physiology especially related to respiration. The image-guided radiation beam control, or tumor tracking, further realized the endeavor for precision-targeting. During tumor tracking, the respiratory motion is often constantly monitored by non-ionizing beam sources using the body surface as its surrogate. This then has to synchronize with the actual internal tumor motion. The latter is often accomplished by stereo X-ray imaging or similar techniques. With these advanced technologies, one may drastically reduce the treated volume and increase the clinicians’ confidence for a high fractional ablative radiation dose. However, the challenges in implementing the motion management may not be trivial and is dependent on each clinic case. This session of presentations is intended to provide an overview of the current techniques used in managing the tumor motion in SBRT, specifically for routine lung SBRT, proton based treatments, and newly-developed MR guided RT. Learning Objectives: Through this presentation, the audience will understand basic roles of commonly used imaging modalities for lung cancer studies; familiarize the major advantages and limitations of each discussed motion control methods; familiarize the major advantages and limitations of each discussed radiation beam control methodology and tumor tacking method; understand the key points in motion management for a high quality SBRT program.

60 APPLIED LIFE SCIENCES↗

Design optimization of MAPS-based detectors using a data-driven fast simulation approach

A parametric simulation tool for pixel sensors is presented. A realistic pixel response is simulated purely based on measurement input, without requiring detailed knowledge of the underlying manufacturing process. As such, it provides an efficient alternative to the use of Technology Computer-Aided Design simulations, which typically depend on proprietary process information. Due to its parametric approach, the package is fast and thus particularly useful for larger detector systems and high hit rate environments. This work presents measurements, simulation and its validation for the MALTA2 sensor. It is a small collection electrode monolithic active pixel sensor produced in the Tower 180 nm complementary metal-oxide-semiconductor imaging process. Modifications to the sensor’s periphery, mainly in the hit merger, are studied in order to optimize the performance for tracking and calorimetry. This optimization is of special interest as part of the MALTA3 sensor redesign in the 65 nm Tower Partners Semiconductor Co. process.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Temperature Effects on Droplet Oscillation Decay with Application to Fuel Property Measurement

Observation of oscillation decay in droplets has been shown to be an effective approach in determining physical properties such as viscosity and surface tension for emerging biofuels using μl quantities. Herein this work extends the approach to higher temperatures relevant to fuel injection conditions for internal combustion engines. Experiments are conducted that use high-resolution strobed imaging of moving, heated, μm-sized, fuel droplets to capture shape oscillation decay through image processing and analysis. Two fuels are investigated, iso-butanol and a primary reference fuel (PRF 84), which is a mixture of iso-octane and n-heptane. A piezoelectric droplet generator is used to generate a continuous train of single droplets, which are given an initial perturbation and subsequently undergo damped oscillations, captured using strobed imaging. Surface tension and viscosity calculated at four different temperatures ranging from 30°C-55°C using the frequency and decay time associated with the fundamental mode are found to be within ~ 10% of reference values obtained from the literature. Complementary numerical simulations are performed that utilize a volume-of-fluid approach to track transient droplet oscillation phenomena along with heat and mass transfer in a 2D axisymmetric domain. Simulations, where droplet size and temperature can be independently varied, capture an expected decrease in oscillation frequency and increase in decay time, with increase in fuel temperature. The simulations are further used to study the relative contribution to deviations in surface tension and viscosity predictions due to heat and mass transfer from the droplet, as well as viscous effects violating the inviscid flow assumption in the droplet oscillation theory. Mass loss effects are found to be negligible. Temperature change due to heat transfer is found to have the next highest sensitivity, particularly for the more volatile PRF 84, which has a lower viscosity and associated Ohnesorge number. For isobutanol, which has a higher viscosity and Ohnesorge number, viscous effects contribute the most to deviation in fuel property predictions.

09 BIOMASS FUELS↗

Sky camera geometric calibration using solar observations

A camera model and associated automated calibration procedure for stationary daytime sky imaging cameras is presented. The specific modeling and calibration needs are motivated by remotely deployed cameras used to forecast solar power production where cameras point skyward and use 180° fisheye lenses. Sun position in the sky and on the image plane provides a simple and automated approach to calibration; special equipment or calibration patterns are not required. Sun position in the sky is modeled using a solar position algorithm (requiring latitude, longitude, altitude and time as inputs). Sun position on the image plane is detected using a simple image processing algorithm. The performance evaluation focuses on the calibration of a camera employing a fisheye lens with an equisolid angle projection, but the camera model is general enough to treat most fixed focal length, central, dioptric camera systems with a photo objective lens. Calibration errors scale with the noise level of the sun position measurement in the image plane, but the calibration is robust across a large range of noise in the sun position. In conclusion, calibration performance on clear days ranged from 0.94 to 1.24 pixels root mean square error.

54 ENVIRONMENTAL SCIENCES↗

Adapting the Reconfigurable SpaceCube Processing System for Multiple Mission Applications

This paper will detail the use of SpaceCube in multiple space flight applications including the Hubble Space Telescope Servicing Mission 4 (HST-SM4), an International Space Station (ISS) radiation test bed experiment, and the main avionics subsystem for two separate ISS attached payloads. Each mission has had varying degrees of data processing complexities, performance requirements, and external interfaces. We will show the methodology used to minimize the changes required to the physical hardware, FPGA designs, embedded software interfaces, and testing.This paper will summarize significant results as they apply to each mission application. In the HST-SM4 application we utilized the FPGA resources to accelerate portions of the image processing algorithms more than 25 times faster than a standard space processor in order to meet computational speed requirements. For the ISS radiation on-orbit demonstration, the main goal is to show that we can rely on the commercial FPGAs and processors in a space environment. We describe our FPGA and processor radiation mitigation strategies that have resulted in our eight PowerPCs being available and error free for more than 99.99 of the time over the period of four years. This positive data and proven reliability of the SpaceCube on ISS resulted in the Department of Defense (DoD) selecting SpaceCube, which is replacing an older and slower computer currently used on ISS, as the main avionics for two upcoming ISS experiment campaigns. This paper will show how we quickly reconfigured the SpaceCube system to meet the more stringent reliability requirements

SpaceCube↗