Search NASA⌕ Search

SEARCH · Search NASA

Results for “Life Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Graphical method for predicting life of a rocket thrust chamber with half-hard zirconium-copper liner and electroformed nickel closeout

A method for estimating the life of a regeneratively cooled rocket thrust chamber was developed and is based on the hot-gas wall temperature and the temperature difference between the hot-gas wall and the outside surface of the closeout. This method permits a quick estimate of the life of a thrust chamber when design changes or test-cycle variations are considered. Strain range and life are presented graphically as functions of these temperature parameters for a typical high-performance rocket thrust chamber with a half-hard zirconium-copper liner and an electroformed nickel closeout.

Kasper, H. J.↗

Investigation of Problems Associated with the Use of Alloyed Molybdenum Sheet in Structures at Elevated Temperatures

The results of an experimental study to explore the capabilities and limitations of thin Mo-0.5Ti molybdenum-alloy sheet for structural applications at high temperatures are presented. Evaluation tests at temperatures ranging from room temperature,to 3000 F were made on resistance-welded corrugated-core sandwiches that were coated with a commercially available oxidation resistant coating known as W-2 and on coated oxidation and tensile specimens. The performance of the corrugated-core sandwiches in compressive strength and static oxidation tests, tensile properties of the coated molybdenum sheet, and the life of the coated specimens in static oxidation tests are given. A description of the equipment and procedures utilized in performing the evaluation tests is included.

Mathauser, Eldon E.↗

Design, Manufacturing, Assembly, Testing, and Lessons Learned of the Prototype 650 MHz Couplers

Six 650 MHz high-power couplers will be integrated into the prototype High Beta 650 MHz (HB650) cryomodule for the PIP-II project at Fermilab. The design of the coupler is described, including design optimizations from the previous generation. This paper then describes the coupler life-cycle, including manufacturing, assembly, testing, conditioning and the lessons learned at each stage.

43 PARTICLE ACCELERATORS↗

Calorimetric thermal-vacuum performance characterization of the BAe 80 K space cryocooler

A comprehensive characterization program is underway at JPL to generate test data on long-life, miniature Stirling-cycle cryocoolers for space application. The key focus of this paper is on the thermal performance of the British Aerospace (BAe) 80 K split-Stirling-cycle cryocooler as measured in a unique calorimetric thermal-vacuum test chamber that accurately simulates the heat-transfer interfaces of space. Two separate cooling fluid loops provide precise individual control of the compressor and displacer heatsink temperatures. In addition, heatflow transducers enable calorimetric measurements of the heat rejected separately by the compressor and displacer. Cooler thermal performance has been mapped for coldtip temperatures ranging from below 45 K to above 150 K, for heatsink temperatures ranging from 280 K to 320 K, and for a wide variety of operational variables including compressor-displacer phase, compressor-displacer stroke, drive frequency, and piston-displacer dc offset.

Kotsubo, V. Y.↗

Statistical fatigue of unnotched composite laminates

A general analytical, phenomenological model is developed for characterizing fatigue damage accumulation in unnotched composite laminates, and experimental results are used to evaluate the model. The fatigue model, which is developed for various types of cyclic loadings, is based on the assumption that the residual strength reduction is a monotonically decreasing function of the fatigue life. Parameters are determined from baseline test data consisting of one set of residual strength data, one set of static strength data, and one set of constant amplitude fatigue life data. Once the parameters are determined, the model is able to predict: (1) the statistical distribution of the fatigue life, and the residual strength under constant and variable amplitude loads, and (2) the effect of periodic proof tests, without any additional experimental data. Experimental test results show that predictions made from the present model agree quite well with the experimental results. The model is also applicable to fatigue of bonded or bolted composite joints.

Yang, J. N.↗

Design and Testing of the Primary and Secondary Oxygen Regulators for the Flexible Portable Life Support System (FlexPLSS)

The next generation space suit requires additional capabilities for controlling and adjusting internal pressure compared to that of historical designs. Although the general configuration of the oxygen systems for the next generation space suit is similar or derived from the Apollo and Shuttle Extravehicular Mobility Unit (EMU) with Primary closed loop life support operation and Secondary sourced open loop life support operations, nearly everything else has evolved with new available technologies. For the case of the primary and secondary regulators, the design has gone away from purely mechanical systems actuated with pull-cords or "bicycle cables" to electro-mechanical hybrids that provide the best of both worlds with respect to power draw, reliability, and versatility. This paper discusses the development and testing of a Secondary Oxygen Regulator bench-top prototype along with comparisons of operation with the various prototypes for the Primary Oxygen Regulator.

Campbell, Colin↗

Results and Interpretation of the WFRD ELS Distillation Down-Select Test Data

Testing of the Wiped-film Rotating-disk (WFRD) evaporator was conducted in support of the Exploration Life Support Distillation Down-Select Test. The WFRD was constructed at NASA Ames Research Center (ARC) and tested at NASA Marshall Space Flight Center (MSFC). The WFRD was delivered to MSFC in September 2009, and testing of solution #1 and solution #2 immediately following. Solution #1 was composed of humidity condensate and urine, including flush water and pretreatment chemicals. Solution #2 was composed of hygiene water, humidity condensate, and urine, including flush water and pretreatment chemicals. During the testing, the operational parameters of the WFRD were recorded and samples of the feed, brine, and product were collected and analyzed. The steady-state results of processing 414L of feed solution #1 and 1283L of feed solution #2 demonstrated that running the WFRD at a brine temperature of 50 C gave an average production rate of 16.7 L/hr. The specific energy consumption was 80.5W-hr/L. Data Analysis shows that the water recovery rates were 94% and 91%, respectively. The total mass of the WFRD as delivered to MSFC was 300 Kg. The volume of the tests stand rack was 1m width x 0.7m depth x 1.9m height or 1.5 cu m of which about half of the total volume is occupied by equipment. Chemical analysis of the distillate showed an average TOC of 20ppm, a pH of 3.5, and a conductivity of 98 mho/cm. The conductivity of the distillate, compared to the feed, decreased by 98.9%., the total ion concentration decreased by 99.6%, the total organics decreased 98.6%, and the metals were at or below detection limits

Delzeit, Lance Dean↗

Phase VI Glove Durability Testing

The current state-of-the-art space suit gloves, the Phase VI gloves, have an operational life of 25 - 8 hour Extravehicular Activities (EVAs) in a clean, controlled ISS environment. Future planetary outpost missions create the need for space suit gloves which can endure up to 90 - 8 hour traditional EVAs or 576 - 45 minute suit port-based EVAs in a dirty, uncontrolled planetary environment. Prior to developing improved space suit gloves for use in planetary environments, it is necessary to understand how the current state-of-the-art performs in these environments. The Phase VI glove operational life has traditionally been certified through cycle testing consisting of ISS-based tasks in a clean environment, and glove durability while performing planetary EVA tasks in a dirty environment has not previously been characterized. Testing was performed in the spring of 2010 by the NASA Johnson Space Center Crew and Thermal Systems Division to characterize the durability of the Phase VI Glove and identify areas of the glove design which need improvement to meet the requirements of future NASA missions. Lunar simulant was used in this test to help replicate the dirty lunar environment, and generic planetary surface EVA tasks were performed during testing. A total of 50 manned, pressurized test sessions were completed in the Extravehicular Mobility Unit (EMU) using one pair of Phase VI gloves as the test article. The 50 test sessions were designed to mimic the total amount of pressurized cycling the gloves would experience over a 6 month planetary outpost mission. The gloves were inspected at periodic intervals throughout testing, to assess their condition at various stages in the test and to monitor the gloves for failures. Additionally, motion capture and force data were collected during 18 of the 50 test sessions to assess the accuracy of the cycle model predictions used in testing and to feed into the development of improved cycle model tables. This paper provides a detailed description of the test hardware and methodology, shares the results of the testing, and provides recommendations for future work.

Mitchell, Kathryn C.↗

Phase VI Glove Durability Testing

The current state-of-the-art space suit gloves, the Phase VI gloves, have an operational life of 25 -- 8 hour Extravehicular Activities (EVAs) in a dust free, manufactured microgravity EVA environment. Future planetary outpost missions create the need for space suit gloves which can endure up to 90 -- 8 hour traditional EVAs or 576 -- 45 minute suit port-based EVAs in a dirty, uncontrolled planetary environment. Prior to developing improved space suit gloves for use in planetary environments, it is necessary to understand how the current state-of-the-art performs in these environments. The Phase VI glove operational life has traditionally been certified through cycle testing consisting of International Space Station (ISS)-based EVA tasks in a clean environment, and glove durability while performing planetary EVA tasks in a dirty environment has not previously been characterized. Testing was performed in the spring of 2010 by the NASA Johnson Space Center (JSC) Crew and Thermal Systems Division (CTSD) to characterize the durability of the Phase VI Glove and identify areas of the glove design which need improvement to meet the requirements of future NASA missions. Lunar simulant was used in this test to help replicate the dirty lunar environment, and generic planetary surface EVA tasks were performed during testing. A total of 50 manned, pressurized test sessions were completed in the Extravehicular Mobility Unit (EMU) using one pair of Phase VI gloves as the test article. The 50 test sessions were designed to mimic the total amount of pressurized cycling the gloves would experience over a 6 month planetary outpost mission. The gloves were inspected periodically throughout testing, to assess their condition at various stages in the test and to monitor the gloves for failures. Additionally, motion capture and force data were collected during 18 of the 50 test sessions to assess the accuracy of the cycle model predictions used in testing and to feed into the development of improved cycle model tables. This paper provides a detailed description of the test hardware and methodology, shares the results of the testing, and provides recommendations for future work.

Mitchell, Kathryn↗

Atacama Rover Astrobiology Drilling Studies Project: Final Year

The Atacama Rover Astrobiology Drilling Studies (ARADS) project, a simulated Mars rover biomarker detection mission, was iteratively developed over four years from 2015 -2019, including three NASA centers, the Centro de Astrobiologia, Johns Hopkins University, Honeybee Robotics, Maxar and the University of Antofagasta. The final (4th) ARADS field season, in 2019, tested an integrated mobile life-prospecting platform loosely inspired by the 2000’s Astrobiology Field Laboratory concept, with a 1m rotary-percussive drill and sample transfer robot arm that fed three astrobiology instruments operating in-situ on the KREX2 medium rover prototype. A fourth instrument was field tested earlier in 2019 due to flight mission requirements. In the final ARADS field deployment in September 2019, the project conducted a remote mission operation simulation (Stoker 2022)demonstrating sample drilling, acquisition and transfer into the rover instruments (while minimizing cross-contamination), performing in-situ analysis of the samples, and returning the results to a remote science operations team(which commanded the daily science goals and uploaded operations sequences).

astrobiology↗

Testing of a Neon Loop Heat Pipe for Large Area Cryocooling

Cryocooling of large areas such as optics, detector arrays, and cryogenic propellant tanks is required for future NASA missions. A cryogenic loop heat pipe (CLHP) can provide a closed-loop cooling system for this purpose and has many advantages over other devices in terms of reduced mass, reduced vibration, high reliability, and long life. A neon CLHP was tested extensively in a thermal vacuum chamber using a cryopump as the heat sink to characterize its transient and steady performance and verify its ability to cool large areas or components. Tests conducted included loop cool-down from the ambient temperature, startup, power cycle, heat removal capability, loop capillary limit and recovery from a dry-out, low power operation, and long duration steady state operation. The neon CLHP demonstrated robust operation. The loop could be cooled from the ambient temperature to subcritical temperatures very effectively, and could start successfully by applying power to both the pump and evaporator without any pre-conditioning. It could adapt to changes in the pump power andor evaporator power, and reach a new steady state very quickly. The evaporator could remove heat loads between 0.25W and 4W. When the pump capillary limit was exceeded, the loop could resume its normal function by reducing the pump power. Steady state operations were demonstrated for up to 6 hours. The ability of the neon loop to cool large areas was therefore successfully verified.

Cryogenics↗

NASA's Biomass Production Chamber: a testbed for bioregenerative life support studies

The Biomass Production Chamber (BPC) located at Kennedy Space Center, FL, USA provides a large (20 m2 area, 113 m3 vol.), closed environment for crop growth tests for NASA's Controlled Ecological Life Support System (CELSS) program. Since the summer of 1988, the chamber has operated on a near-continuous basis (over 1200 days) without any major failures (excluding temporary power losses). During this time, five crops of wheat (64-86 days each), three crops of soybean (90 to 97 days), five crops of lettuce (28-30 days), and four crops of potato (90 to 105 days were grown, producing 481 kg of dry plant biomass, 196 kg edible biomass, 540 kg of oxygen, 94,700 kg of condensed water, and fixing 739 kg of carbon dioxide. Results indicate that total biomass yields were close to expected values for the given light input, but edible biomass yields and harvest indices were slightly lower than expected. Stand photosynthesis, respiration, transpiration, and nutrient uptake rates were monitored throughout growth and development of the different crops, along with the build-up of ethylene and other volatile organic compounds in the atmosphere. Data were also gathered on system hardware maintenance and repair, as well as person-hours required for chamber operation. Future tests will include long-term crop production studies, tests in which nutrients from waste treatment systems will be used to grow new crops, and multi-species tests.

NASA Center KSC↗

CFD analysis to optimize a design modification of BSMT

The Bearings, Seals and Materials Tester (BSMT) is a test article being used at MSFC to evaluate the performance of conventional rolling contact bearings. Pressure differentials between the BSMT inlet and exit cavities are found to cause large parasitic axial loads on the bearing-carrier walls. These parasitic loads, besides being detrimental to the life of bearings, make the testing and evaluation of bearing performance very difficult, and need to be eliminated if at all possible. The objectives of this study are to estimate the hydrodynamic loads on the bearings and to recommend feasible design modifications for BSMT to eliminate the parasitic loads. Three-dimensional computational analyses of inlet and exit cavities in their baseline configuration were performed with REFLEQS which is an advanced finite-volume Navier-Stokes code. Computations were performed with and without a 1/4 inch diameter temperature probe included in each of the cavities. The results of the analyses indicate that the temperature probes substantially alter the flow field and reduce the pressure drop/rise in the cavities. The overall pressure drop across the tester compares quite well with the measurements.

Ratcliff, Mark↗

Probabilistic Analysis for Comparing Fatigue Data Based on Johnson-Weibull Parameters

Leonard Johnson published a methodology for establishing the confidence that two populations of data are different. Johnson's methodology is dependent on limited combinations of test parameters (Weibull slope, mean life ratio, and degrees of freedom) and a set of complex mathematical equations. In this report, a simplified algebraic equation for confidence numbers is derived based on the original work of Johnson. The confidence numbers calculated with this equation are compared to those obtained graphically by Johnson. Using the ratios of mean life, the resultant values of confidence numbers at the 99 percent level deviate less than 1 percent from those of Johnson. At a 90 percent confidence level, the calculated values differ between +2 and 4 percent. The simplified equation is used to rank the experimental lives of three aluminum alloys (AL 2024, AL 6061, and AL 7075), each tested at three stress levels in rotating beam fatigue, analyzed using the Johnson- Weibull method, and compared to the ASTM Standard (E739 91) method of comparison. The ASTM Standard did not statistically distinguish between AL 6061 and AL 7075. However, it is possible to rank the fatigue lives of different materials with a reasonable degree of statistical certainty based on combined confidence numbers using the Johnson- Weibull analysis. AL 2024 was found to have the longest fatigue life, followed by AL 7075, and then AL 6061. The ASTM Standard and the Johnson-Weibull analysis result in the same stress-life exponent p for each of the three aluminum alloys at the median, or L(sub 50), lives

Vlcek, Brian L.↗

ECLSS regenerative systems comparative testing and subsystem selection

In support of Space Station Freedom Phase C/D Environmental Control and Life Support Systems (ECLSS) regenerative systems development, comparative testing was performed on predevelopment hardware of competing technologies for each regenerative function. The purpose of the test program was to collect data on latest generation hardware in order to make final technology selections for each subassembly in the oxygen recovery and water reclamation strings. This paper discusses the testing performed, test results, and evaluation of these results relative to subsystem selections for CO2 reduction, O2 generation, potable water processing, hygiene water processing, and urine processing.

Carasquillo, Robyn L.↗

International Space Station (ISS) Low Pressure Intramodule Quick Disconnect Failures

A failure of an ISS intermodule Quick Disconnect (QD) during protoflight vibration testing of ISS regenerative Environmental Control and Life Support (ECLS) hardware led to the discovery of QD design, manufacturing, and test flaws which can yield the male QD susceptible to failure of the secondary housing seal and inadequate housing assembly locking mechanisms. Discovery of this failure had large implications when considering that currently there are 399 similar units on orbit and approximately 1100 units on the ground integrated into flight hardware. Discovery of the nature of the failure required testing and analysis and implementation of a recovery plan requiring part screening and review of element level and project hazard analysis to determine if secondary seals are required. Implementation also involves coordination with the Nodes and MPLM project offices, Regenerative ECLS Project, ISS Payloads, JAXA, ESA, and ISS Logistics and Maintenance.

Lewis, John F.↗

Detection of microbes in the subsurface

The search for evidence of microbial life in the deep subsurface of Earth has implications for the Mars Rover Sampling Return Missions program. If suitably protected environments can be found on Mars then the instrumentation to detect biomarkers could be used to examine the molecular details. Finding a lipid in Martian soil would represent possibly the simplest test for extant or extinct life. A device that could do a rapid extraction possibly using the supercritical fluid technology under development now with a detection of the carbon content would clearly indicate a sample to be returned.

White, David C.↗

Effect of Environment on Stress-Rupture Behavior of a Carbon Fiber-Reinforced Silicon Carbide (C/SiC) Ceramic Matrix Composite

Stress-rupture tests were conducted in air, vacuum, and steam-containing environments to identify the failure modes and degradation mechanisms of a carbon fiber-reinforced silicon carbide (C/SiC) composite at two temperatures, 600 and 1200 C. Stress-rupture lives in air and steam containing environments (50 - 80% steam with argon) are similar for a composite stress of 69 MPa at 1200 C. Lives of specimens tested in a 20% steam/argon environment were about twice as long. For tests conducted at 600 C, composite life in 20% steam/argon was 20 times longer than life in air. Thermogravimetric analysis of the carbon fibers was conducted under similar conditions to the stress-rupture tests. The oxidation rate of the fibers in the various environments correlated with the composite stress-rupture lives. Examination of the failed specimens indicated that oxidation of the carbon fibers was the primary damage mode for specimens tested in air and steam environments at both temperatures.

Verrilli, Michael J.↗