Analysis of Lobe Power Calculator and Indication System with Physics and Cycle Based Models

The Advanced Test Reactor (ATR) at INL measures reactor power through various methods, two of them being thermal and Nitrogen-16 (N-16) activity. Water power calculator (WPC) is a thermal power system that measures flow and temperature to determine thermal quadrant powers. The N-16 system utilizes a beta detector that outputs Nitrogen activation levels to calculate lobe power through an algorithm called Lobe Power Calculation and Indication system (LPCIS). The LPCIS utilizes the N-16 system and the WPC system to determine reactor core power levels. The WPC provides accurate calculations of quadrant and total reactor thermal power. With the use of WPC measurements, thermal-to-N-16 (T2N) power ratios are produced to determine if the two indication systems agree on core power. Relative magnitude equations are used to utilize N-16 coefficients and multipliers to improve the indications of the LPCIS. These correct indications are crucial for maintaining safety limits because operators rely on this information for decision making. Currently, the LPCIS system uses linear equations and matrices to calculate lobe power through multipliers and coefficients. Advancements in technology and system upgrades have increased the accuracy of power readings by making the system more dynamic. The new proposed coefficient and multiplier method implements a cycle specific and physics-based model intended for changing coefficients during operation. This calibration experiment focused on power splitting, outer shim and neck shim, as well as fuel burning into the reactor digital acquisition system (RDAS) weighting factors. Results demonstrated that the physics learning method yields a smaller error margin inside of the desired power range for the data set 166-A. Continuing to improve the physics-based model will help improve the power accuracy of the LPCIS system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Accurate prediction of core-level spectra of radicals at density functional theory cost via square gradient minimization and recoupling of mixed configurations

State-specific orbital optimized approaches are more accurate at predicting core-level spectra than traditional linear-response protocols, but their utility had been restricted due to the risk of "variational collapse" down to the ground state. We employ the recently developed square gradient minimization algorithm to reliably avoid variational collapse and study the effectiveness of orbital optimized density functional theory (DFT) at predicting second period element 1s core-level spectra of open-shell systems. Several density functionals (including SCAN, B3LYP, and ωB97X-D3) are found to predict excitation energies from the core to singly occupied levels with high accuracy (≤0.3 eV RMS error) against available experimental data. Higher excited states are, however, more challenging by virtue of being intrinsically multiconfigurational. We thus present a configuration interaction inspired route to self-consistently recouple single determinant mixed configurations obtained from DFT, in order to obtain approximate doublet states. This recoupling scheme is used to predict the C K-edge spectra of the allyl radical, the O K-edge spectra of CO + , and the N K-edge of NO 2 with high accuracy relative to experiment, indicating substantial promise in using this approach for the computation of core-level spectra for doublet species [vs more traditional time dependent DFT, equation of motion coupled cluster singles and doubles (EOM-CCSD), or using unrecoupled mixed configurations]. Finally, we also present general guidelines for computing core-excited states from orbital optimized DFT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photo-z outlier self-calibration in weak lensing surveys

Calibrating photometric redshift errors in weak lensing surveys with external data is extremely challenging. In this work, we show that both Gaussian and outlier photo-z parameters can be self-calibrated from the data alone. This comes at no cost for the neutrino masses, curvature and dark energy equation of state w0, but with a 65% degradation when both w0 and wa are varied. We perform a realistic forecast for the Vera Rubin Observatory (VRO) Legacy Survey of Space and Time (LSST) 3× 2 analysis, combining cosmic shear, projected galaxy clustering and galaxy - galaxy lensing. We confirm the importance of marginalizing over photo-z outliers. We examine a subset of internal cross-correlations, dubbed "null correlations", which are usually ignored in 3× 2 analyses. Despite contributing only ~ 10% of the total signal-to-noise, these null correlations improve the constraints on photo-z parameters by up to an order of magnitude. Using the same galaxy sample as sources and lenses dramatically improves the photo-z uncertainties too. Together, these methods add robustness to any claim of detected new Physics, and reduce the statistical errors on cosmology by 15% and 10% respectively. Finally, including CMB lensing from an experiment like Simons Observatory or CMB-S4 improves the cosmological and photo-z posterior constraints by about 10%, and further improves the robustness to systematics. To give intuition on the Fisher forecasts, we examine in detail several toy models that explain the origin of the photo-z self-calibration. Our Fisher code LaSSI (Large-Scale Structure Information), which includes the effect of Gaussian and outlier photo-z, shear multiplicative bias, linear galaxy bias, and extensions to LCDM, is publicly available at \href{https://github.com/EmmanuelSchaan/LaSSI}{https://github.com/EmmanuelSchaan/LaSSI}.

79 ASTRONOMY AND ASTROPHYSICS↗

Theoretical Systematics of Future Baryon Acoustic Oscillation Surveys

Future Baryon Acoustic Oscillation surveys aim at observing galaxy clustering over a wide range of redshift and galaxy populations at great precision, reaching tenths of a percent, in order to detect any deviation of dark energy from the lambda cold dark matter ( ΛCDM ) model. We utilize a set of paired quasi- N -body FastPM simulations that were designed to mitigate the sample variance effect on the BAO feature and evaluated the BAO systematics as precisely as ~0.01 percent. We report anisotropic BAO scale shifts before and after density field reconstruction in the presence of redshift-space distortions over a wide range of redshift, galaxy/halo biases, and shot noise levels. We test different reconstruction schemes and different smoothing filter scales, and introduce physically motivated BAO fitting models. For the first time, we derive a Galilean-invariant infrared resummed model for halos in real and redshift space. We test these models from the perspective of robust BAO measurements and non-BAO information such as growth rate and non-linear bias. We find that pre-reconstruction BAO scale has moderate fitting-model dependence at the level of 0.1–0.2 percent for matter while the dependence is substantially reduced to less than 0.07 percent for halos. We find that post-reconstruction BAO shifts are generally reduced to below 0.1 percent in the presence of galaxy/halo bias and show much smaller fitting model dependence. Different reconstruction conventions can potentially make a much larger difference on the line-of-sight BAO scale, upto 0.3 percent. Furthermore, the precision (error) of the BAO measurements is quite consistent regardless of the choice of the fitting model or reconstruction convention.

(cosmology:) cosmological parameters↗

TH-CD-207A-07: Prediction of High Dimensional State Subject to Respiratory Motion: A Manifold Learning Approach

Purpose: The development of high dimensional imaging systems (e.g. volumetric MRI, CBCT, photogrammetry systems) in image-guided radiotherapy provides important pathways to the ultimate goal of real-time volumetric/surface motion monitoring. This study aims to develop a prediction method for the high dimensional state subject to respiratory motion. Compared to conventional linear dimension reduction based approaches, our method utilizes manifold learning to construct a descriptive feature submanifold, where more efficient and accurate prediction can be performed. Methods: We developed a prediction framework for high-dimensional state subject to respiratory motion. The proposed method performs dimension reduction in a nonlinear setting to permit more descriptive features compared to its linear counterparts (e.g., classic PCA). Specifically, a kernel PCA is used to construct a proper low-dimensional feature manifold, where low-dimensional prediction is performed. A fixed-point iterative pre-image estimation method is applied subsequently to recover the predicted value in the original state space. We evaluated and compared the proposed method with PCA-based method on 200 level-set surfaces reconstructed from surface point clouds captured by the VisionRT system. The prediction accuracy was evaluated with respect to root-mean-squared-error (RMSE) for both 200ms and 600ms lookahead lengths. Results: The proposed method outperformed PCA-based approach with statistically higher prediction accuracy. In one-dimensional feature subspace, our method achieved mean prediction accuracy of 0.86mm and 0.89mm for 200ms and 600ms lookahead lengths respectively, compared to 0.95mm and 1.04mm from PCA-based method. The paired t-tests further demonstrated the statistical significance of the superiority of our method, with p-values of 6.33e-3 and 5.78e-5, respectively. Conclusion: The proposed approach benefits from the descriptiveness of a nonlinear manifold and the prediction reliability in such low dimensional manifold. The fixed-point iterative approach turns out to work well practically for the pre-image recovery. Our approach is particularly suitable to facilitate managing respiratory motion in image-guide radiotherapy. This work is supported in part by NIH grant R01 CA169102-02.

60 APPLIED LIFE SCIENCES↗

Scalable line and plane relaxation in a parallel structured multigrid solver

The efficient solution of sparse, linear systems that arise through the discretization of partial differential equations remains a key challenge for a range of high performance scientific simulations. One approach for reducing data movement and improving performance is by exposing and exploiting structure in a problem through the use of robust structured multilevel solvers. By choosing coarsening that preserves the structure of the problem, these methods maintain efficient structured computation and communication throughout the multigrid hierarchy. However, when coarsening is not permitted to be dependent on the operator, anisotropy must be addressed by the smoother — producing error compatible for coarse-grid correction with structured coarsening. Here, the components required in a scalable parallel structured solver are described with a focus on memory and communication efficiency of robust smoothers. While the implementation of communication and memory reduction techniques in smoothers integrated in a complete 3D solver present a significant engineering challenge, a novel approach is proposed that addresses these challenges systematically through a change to the solver’s execution model. Enabled by user-level threading paired with a set of data and communication abstractions, this approach permits seamless aggregation of communication in plane smoothers — directly reusing code for a 2D distributed multilevel cycle. Results show an effective reduction in communication costs for coarse-grid problems, and result in a speedup of 8.7x in smoothing routines shown in Fig. 12 using this approach. This produces a significant improvement to strong scalability while maintaining favorable weak scaling behavior. Finally, a parallel scaling study using a series of refined meshes is included that demonstrates the effectiveness of this approach in an application of interest.

97 MATHEMATICS AND COMPUTING↗

Efficient linear-scaling second-order Møller-Plesset perturbation theory: The divide–expand–consolidate RI-MP2 model

The Resolution of the Identity second-order Møller-Plesset perturbation theory (RI-MP2) method is implemented within the linear-scaling Divide-Expand-Consolidate (DEC) framework. In a DEC calculation, the full molecular correlated calculation is replaced by a set of independent fragment calculations each using a subset of the total orbital space. The number of independent fragment calculations scales linearly with the system size, rendering the method linear-scaling and massively parallel. The DEC-RI-MP2 method can be viewed as an approximation to the DEC-MP2 method where the RI approximation is utilized in each fragment calculation. The individual fragment calculations scale with the fifth power of the fragment size for both methods. However, the DEC-RI-MP2 method has a reduced prefactor compared to DEC-MP2 and is well-suited for implementation on massively parallel supercomputers, as demonstrated by test calculations on a set of medium-sized molecules. The DEC error control ensures that the standard RI-MP2 energy can be obtained to the predefined precision. The errors associated with the RI and DEC approximations are compared, and it is shown that the DEC-RI-MP2 method can be applied to systems far beyond the ones that can be treated with a conventional RI-MP2 implementation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation asymmetry during shattered pellet and massive gas injection in DIII-D

Infrared thermography of the first wall in DIII-D is used to show the toroidal peaking of plasma radiation during mitigated disruptions with shattered pellet injection (SPI) and with massive gas injection (MGI). During MGI, the radiation peak location is shown to be due to the n = 1 magnetohydrodynamic (MHD) activity and continuously variable in toroidal phase based on externally applied error fields, consistent with previous experimental results. Furthermore, the measured toroidal peaking factor (TPF) is in agreement with the previous estimates based on radiometry, with a total TPF of 1.07 ± 0.05 when integrated over the entire duration of the disruption, and a value of 1.3 ± 0.1 during the thermal quench (TQ). For SPI, the location of the radiation peak is found to be determined predominantly by the particle source location, and thus can be varied on DIII-D by injecting from either of two toroidally separated injectors. 3D non-linear MHD simulations with the NIMROD code support this picture. The localized SPI particle source leads to higher peaking than for MGI, with a total TPF of 1.3 ± 0.1 over the full disruption and a TQ TPF of 1.9 +0.5/−0.3, a value also consistent with the NIMROD simulations. This TQ value is close to or potentially exceeding the allowable limit for the previously planned Be first wall in ITER, pointing to the importance of radiation asymmetries depending on the choice of first wall material.

Physics - Plasma physics↗

Life-cycle environmental impacts of single-junction and tandem perovskite PVs: a critical review and future perspectives

For new technologies, such as perovskite solar cells (PSC), life cycle analysis (LCA) offers a fundamental framework for examining potential environmental, energy and health impacts and mitigation options before large-scale commercialization and for guiding improvements in development and production that further reduce their environmental footprint. However, credible LCA studies require actual process-based material, energy and emissions data, which may not exist before the technologies are commercially produced. Thus, the perovskite LCA literature is based on linear extrapolations of laboratory data. In this paper we critically reviewed the PSC LCA literature, explain the reasoning for a wide divergence of results, and determined which data apply to scalable industrial production, materials and processes. Our investigation probed into the formulation of each layer of a PSC device, and its potential for industrial scale fabrication. We found that electricity use is the main contributor to reported LCA results, explaining the large difference, ranging from 7.78 kWh to 1,460 kWh/m –2 , among various studies. Subsequently, we identified and discuss methodological errors in some of these estimates. In terms of life-cycle toxicity most of the reviewed LCA studies do not attribute any major overall toxicity impact to the presence of lead in the PSC devices. We also reviewed and critiqued studies describing “worst-case” scenarios of accidental release of lead into the environment, and, in spite of statements in those studies, we found them to be inconclusive. Lastly, we discussed end-of-life (EoL) management options for resource recovery and for minimizing environmental impacts.

14 SOLAR ENERGY↗

The impact of the fiducial cosmology assumption on BAO distance scale measurements

ABSTRACT Standard analysis pipelines for measurements of Baryon Acoustic Oscillations (BAO) in galaxy surveys make use of a fiducial cosmological model to guide the data compression required to transform from observed redshifts and angles to the measured angular and radial BAO peak positions. In order to remove any dependence on the fiducial cosmology from the results, all models compared to the data should mimic the compression and its dependence on the fiducial model. In practice, approximations are made when testing models: (1) There is assumed to be no residual dependence on the fiducial cosmology after reconstruction, (2) differences in the distance–redshift relationship are assumed to match a linear scaling, and (3) differences in clustering between true and fiducial models are assumed to be removed by the free parameters used to null the non-BAO signal. We test these approximations using the current standard measurement procedure with a set of halo catalogues from the aemulus suite of N-body simulations, which span a range of wCDM cosmological models. We focus on reconstruction of the primordial BAO and locating the BAO. For the range of wCDM cosmologies covered by the aemulus suite, we find no evidence for systematic errors in the measured BAO shift parameters α∥ and α⊥ to $\lt 0.1\%$. However, the measured errors $\sigma _{\alpha _{\parallel }}$ and $\sigma _{\alpha _{\bot }}$ show a notable absolute increase by up to +0.001 and +0.002, respectively, in the case that the fiducial cosmology does not match the truth. These effects on the inferred BAO scale will be important, given the precision of measurements expected from future surveys including DESI, Euclid, and WFIRST.

79 ASTRONOMY AND ASTROPHYSICS↗

Lithium-Ion Battery Diagnostics Using Electrochemical Impedance via Machine-Learning

Diagnosing battery states such as health, state-of-charge, or temperature is crucial for ensuring the safety and reliability of electrochemical energy storage systems. While some states, such as temperature, may be measured using cheap sensors, accurate diagnosis of battery health metrics usually requires time-consuming performance measurements, making them infeasible for use in real-world operation. These health metrics can be measured during lab-testing and then estimated on-line using predictive life models or via state observer algorithms such as Kalman filters, but these predictive methods should be supplemented by actual measurement of battery health whenever possible to ensure reliability. Rapid measurement of battery health may be done by various types of fast diagnostic techniques such as electrochemical impedance spectroscopy (EIS), which can be performed in only a few minutes and require only a fraction of the energy and power needed for a full charge and discharge measurement. But there is a substantial challenge for estimating battery health using EIS data, as EIS is sensitive to cell temperature, state-of-charge, current, and resting time in addition to health. Thus, utilizing EIS data to predict battery capacity requires correcting for all these additional variables, a task that is extremely difficult to handle analytically. This talk utilizes machine-learning methods to estimate the effectiveness of battery capacity prediction from EIS data, leveraging a data set of hundreds of EIS measurements recorded at varying temperature and state-of-charge throughout a 500-day aging study of 32 commercial, large-format NMC-Graphite lithium-ion batteries. Using EIS as input to machine-learning models is complicated by the nonlinear response of impedance to battery health, temperature, and state-of-charge, as well as the collinearity between the impedance response at neighboring frequencies, which can easily lead to overfit models. To train robust models, features from EIS data need to be extracted from the data or some subset of critical frequencies selected. Many approaches for extracting and selecting features from EIS data from electrochemical analysis and machine-learning fields were identified for analysis: using the entire raw spectra; selection of one, two, or many frequencies from the entire spectra; selecting interesting points from the EIS measurement using domain knowledge; fitting EIS with an equivalent-circuit model; calculating statistics on the raw impedance values; and reducing the dimensionality of the data using unsupervised linear (principal component analysis) and non-linear (uniform manifold approximation and projection) methods. These approaches were rigorously compared using a machine-learning pipeline approach, training linear, Gaussian process, and random forest regression models and quantifying performance using cross-validation as well as a held-out test set. An artificial neural network model trained on the raw spectra was also tested. Promising pipelines were fine-tuned via Bayesian hyperparameter optimization using cross-validation loss and training with class-specific weights to counter data set imbalance. The most reliable method for utilizing impedance in this work was the selection of two optimal frequencies through an exhaustive search, resulting in about 2% mean absolute error on test data for both Gaussian process and random forest model architectures. Interrogation of a variety of models reveals critical frequencies of 100 Hz and 103 Hz for this data set, though the optimal set of frequencies is not necessarily intuitive, i.e., the best performing models are not simply those that use impedance at frequencies that have the highest correlation to the relative discharge capacity. The best performing model is an ensemble model, which is able to predict battery capacity with 1.9% mean absolute error for unseen cells using impedance recorded at a variety of temperatures and states-of-charge.

battery↗

Data-Driven Model Predictive Control for Temperature Management of Heat Pipe Microreactor

To enable the self-regulating capability of heat pipe (HP) microreactors, an anticipatory control strategy through model predictive control (MPC) could proactively respond to potential disturbances and deviations in operating setpoints. However, a key factor prohibiting the widespread adoption of MPCs in nuclear applications is the effort and computational costs associated with learning and calibrating first-principles-based process models when the target system is complex and when there are gaps between modeled and target reactor systems. In this paper, we demonstrate data-driven MPC using three approaches for modeling the system dynamics, including a linear state-space model, feedforward neural network, and recurrent neural networks long short-term memory. We present the development and validation process of each model and compare the performance of data-driven MPCs in controlling the temperatures of selected HPs at the evaporator and condenser regions in a 37-HP-monolith system. Our results show that, qualitatively, all data-driven MPCs are producing similar control actions, while quantitatively, with artificial neural nets (especially feedforward neural nets), MPC can better follow drastic changes in setpoints with smallest errors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Daily QA of linear accelerators using only EPID and OBI

Purpose: As treatment delivery becomes more complex, there is a pressing need for robust quality assurance (QA) tools to improve efficiency and comprehensiveness while simultaneously maintaining high accuracy and sensitivity. This work aims to present the hardware and software tools developed for comprehensive QA of linear accelerator (LINAC) using only electronic portal imaging devices (EPIDs) and kV flat panel detectors. Methods: A daily QA phantom, which includes two orthogonally positioned phantoms for QA of MV-beams and kV onboard imaging (OBI) is suspended from the gantry accessory holder to test both geometric and dosimetric components of a LINAC and an OBI. The MV component consists of a 0.5 cm water-equivalent plastic sheet incorporating 11 circular steel plugs for transmission measurements through multiple thicknesses and one resolution plug for MV-image quality testing. The kV-phantom consists of a Leeds phantom (TOR-18 FG phantom supplied by Varian) for testing low and high contrast resolutions. In the developed process, the existing LINAC tools were used to automate daily acquisition of MV and kV images and software tools were developed for simultaneous analysis of these images. A method was developed to derive and evaluate traditional QA parameters from these images [output, flatness, symmetry, uniformity, TPR{sub 20/10}, and positional accuracy of the jaws and multileaf collimators (MLCs)]. The EPID-based daily QA tools were validated by performing measurements on a detuned 6 MV beam to test its effectiveness in detecting errors in output, symmetry, energy, and MLC positions. The developed QA process was clinically commissioned, implemented, and evaluated on a Varian TrueBeam LINAC (Varian Medical System, Palo Alto, CA) over a period of three months. Results: Machine output constancy measured with an EPID (as compared against a calibrated ion-chamber) is shown to be within ±0.5%. Beam symmetry and flatness deviations measured using an EPID and a 2D ion-chamber array agree within ±0.5% and ±1.2% for crossline and inline profiles, respectively. MLC position errors of 0.5 mm can be detected using a picket fence test. The field size and phantom positioning accuracy can be determined within 0.5 mm. The entire daily QA process takes ∼15 min to perform tests for 5 photon beams, MLC tests, and imaging checks. Conclusions: The exclusive use of EPID-based QA tools, including a QA phantom and simultaneous analysis software tools, has been demonstrated as a viable, efficient, and comprehensive process for daily evaluation of LINAC performance.

60 APPLIED LIFE SCIENCES↗

Application of Failure Mode and Effects Analysis to Intraoperative Radiation Therapy Using Mobile Electron Linear Accelerators

Purpose: Failure mode and effects analysis (FMEA) represents a prospective approach for risk assessment. A multidisciplinary working group of the Italian Association for Medical Physics applied FMEA to electron beam intraoperative radiation therapy (IORT) delivered using mobile linear accelerators, aiming at preventing accidental exposures to the patient. Methods and Materials: FMEA was applied to the IORT process, for the stages of the treatment delivery and verification, and consisted of three steps: 1) identification of the involved subprocesses; 2) identification and ranking of the potential failure modes, together with their causes and effects, using the risk probability number (RPN) scoring system, based on the product of three parameters (severity, frequency of occurrence and detectability, each ranging from 1 to 10); 3) identification of additional safety measures to be proposed for process quality and safety improvement. RPN upper threshold for little concern of risk was set at 125. Results: Twenty-four subprocesses were identified. Ten potential failure modes were found and scored, in terms of RPN, in the range of 42-216. The most critical failure modes consisted of internal shield misalignment, wrong Monitor Unit calculation and incorrect data entry at treatment console. Potential causes of failure included shield displacement, human errors, such as underestimation of CTV extension, mainly because of lack of adequate training and time pressures, failure in the communication between operators, and machine malfunctioning. The main effects of failure were represented by CTV underdose, wrong dose distribution and/or delivery, unintended normal tissue irradiation. As additional safety measures, the utilization of a dedicated staff for IORT, double-checking of MU calculation and data entry and finally implementation of in vivo dosimetry were suggested. Conclusions: FMEA appeared as a useful tool for prospective evaluation of patient safety in radiotherapy. The application of this method to IORT lead to identify three safety measures for risk mitigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Molecular dipole moment learning via rotationally equivariant derivative kernels in molecular-orbital-based machine learning

This study extends the accurate and transferable molecular-orbital-based machine learning (MOB-ML) approach to modeling the contribution of electron correlation to dipole moments at the cost of Hartree–Fock computations. A MOB pairwise decomposition of the correlation part of the dipole moment is applied, and these pair dipole moments could be further regressed as a universal function of MOs. The dipole MOB features consist of the energy MOB features and their responses to electric fields. An interpretable and rotationally equivariant derivative kernel for Gaussian process regression (GPR) is introduced to learn the dipole moment more efficiently. The proposed problem setup, feature design, and ML algorithm are shown to provide highly accurate models for both dipole moments and energies on water and 14 small molecules. To demonstrate the ability of MOB-ML to function as generalized density-matrix functionals for molecular dipole moments and energies of organic molecules, we further apply the proposed MOB-ML approach to train and test the molecules from the QM9 dataset. The application of local scalable GPR with Gaussian mixture model unsupervised clustering GPR scales up MOB-ML to a large-data regime while retaining the prediction accuracy. In addition, compared with the literature results, MOB-ML provides the best test mean absolute errors of 4.21 mD and 0.045 kcal/mol for dipole moment and energy models, respectively, when training on 110 000 QM9 molecules. The excellent transferability of the resulting QM9 models is also illustrated by the accurate predictions for four different series of peptides.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Commissioning a Vibrating Wire System for Quadrupole Fiducialization

Quadrupoles will be placed between the undulator segments in LCLS to keep the electron beam focused as it passes through. The quadrupoles will be assembled with their respective undulator segments prior to being placed into the tunnel. Beam alignment will be used to center the quadrupoles, along with the corresponding undulators, on the beam. If there is any displacement between the undulator and the quadrupole axes in the assemblies, the beam will deviate from the undulator axis. If it deviates by more than 80{micro}m in vertical or 140{micro}m in horizontal directions, the undulator will not perform as required by LCLS. This error is divided between three sources: undulator axis fiducialization, quadrupole magnetic axis fiducialization, and assembly of the two parts. In particular, it was calculated that the quadrupole needs to be fiducialized to within 25{micro}m in both vertical and horizontal directions. A previous study suggested using a vibrating wire system for finding the magnetic axis of the quadrupoles. The study showed that the method has high sensitivity (up to 1{micro}m) and laid out guidelines for constructing such a system. There are 3 steps in fiducializing the quadrupole with the vibrating wire system. They are positioning the wire at the magnet center (step 1), finding the wire with position detectors (step 2), and finding the quadrupole tooling ball positions relative to the position detector tooling balls (step 3). A previous study investigated the error associated with each step by using a permanent quadrupole magnet on an optical mover system. The study reported an error of 11{micro}m for step 1 and a repeatability of 4{micro}m for step 2. However, the set up used a FARO arm to measure tooling balls and didn't allow to accurately check step 2 for errors; an uncertainty of 100{micro}m was reported. Therefore, even though the repeatability was good, there was no way to check that the error in step 2 was small. Following the recommendations of that study, we used a CMM (Coordinate Measuring Machine) instead of the FARO arm for measuring the tooling balls. In addition, a roller cam positioner system replaced the optical movers for moving the quadrupole. With the exception of the quadrupole itself, the system was identical to what will be used in fiducializing the undulator quadrupoles. In this study, we investigate the new vibrating wire set up, including the error associated with each step of fiducialization. A vibrating wire system was constructed to fiducialize the quadrupoles between undulator segments in the LCLS. This note is a continuation of previous work to study the ability of the system to fulfill the fiducialization requirements.

43 PARTICLE ACCELERATORS↗

FACET Tolerances for Static and Dynamic Misalignments

The Facility for AdvancedAccelerator and Experimental Tests (FACET) at the SLAC National Accelerator Laboratory is designed to deliver a beam with a transverse spot size on the order of 10 {micro}m x 10 {micro}m in a new beamline constructed at the two kilometer point of the SLAC linac. Commissioning the beamline requires mitigating alignment errors and their effects, which can be significant and result in spot sizes orders of magnitude larger. Sextupole and quadrupole alignment errors in particular can introduce errors in focusing, steering, and dispersion which can result in spot size growth, beta mismatch, and waist movement. Alignment errors due to static misalignments, mechanical jitter, energy jitter, and other physical processes can be analyzed to determine the level of accuracy and precision that the beamline requires. It is important to recognize these effects and their tolerances in order to deliver a beam as designed.

43 PARTICLE ACCELERATORS↗

A heterogeneous stochastic FEM framework for elliptic PDEs

We introduce a new concept of sparsity for the stochastic elliptic operator −div(a(x,ω)∇(⋅)), which reflects the compactness of its inverse operator in the stochastic direction and allows for spatially heterogeneous stochastic structure. This new concept of sparsity motivates a heterogeneous stochastic finite element method (HSFEM) framework for linear elliptic equations, which discretizes the equations using the heterogeneous coupling of spatial basis with local stochastic basis to exploit the local stochastic structure of the solution space. We also provide a sampling method to construct the local stochastic basis for this framework using the randomized range finding techniques. The resulting HSFEM involves two stages and suits the multi-query setting: in the offline stage, the local stochastic structure of the solution space is identified; in the online stage, the equation can be efficiently solved for multiple forcing functions. An online error estimation and correction procedure through Monte Carlo sampling is given. Numerical results for several problems with high dimensional stochastic input are presented to demonstrate the efficiency of the HSFEM in the online stage.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗