Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Solid-phase extraction microfluidic devices for matrix removal in trace element assay of actinide materials

Advances in sample nebulization and injection technology have significantly reduced the volume of solution required for trace impurity analysis in plutonium and uranium materials. Correspondingly, we have designed and tested a novel chip-based microfluidic platform, containing a 100-µL or 20-µL solid-phase microextraction column, packed by centrifugation, which supports nuclear material mass and solution volume reductions of 90% or more compared to standard methods. Quantitative recovery of 28 trace elements in uranium was demonstrated using a UTEVA chromatographic resin column, and trace element recovery from thorium (a surrogate for plutonium) was similarly demonstrated using anion exchange resin AG MP-1. Of nine materials tested, compatibility of polyvinyl chloride (PVC), polypropylene (PP), and polytetrafluoroethylene (PTFE) chips with the strong nitric acid media was highest. Finally, the microcolumns can be incorporated into a variety of devices and systems, and can be loaded with other solid-phase resins for trace element assay in high-purity metals.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Integrated Flame Spray Process for Low Cost Production of Battery Materials for Lithium Ion Batteries and Beyond

The overall objective of this project was to develop an advanced manufacturing technology for Li-ion battery materials production at low cost and in a green chemical process using glycerol as solvent to replace water. It was aimed at developing a prototype pilot production line to reduce production cost by at least 25% to the baseline. During the course of this project, research was conducted to understand spray drying and combustion of eutectic solvent precursors of glycerol and metal salts (acetates) in the formation of mixed metal oxide powders. Reactor design and optimization were done to facilitate spray drying and combustion in powder formation and processing. Various cathode materials powders were produced, including lithium nickel-cobalt-manganese oxide (NCM) and lithium nickel-cobalt-aluminum oxide (NCA). These cathode materials powders were tested in half coin cells for their performances, with materials performances of 160 mAh/g for NCM111 and 200 mAh/g for NCA. NCA powders were also produced using a slurry spray-drying process and tested in full pouch cells. A pilot scale flame assisted spray drying reactor was constructed and demonstrated for its production rate exceeding the target of production rate of four metric tons per year. The work performed in this project has been documented in 9 peer reviewed journal publications, 8 conference presentations, and two IP disclosures/patent applications.

25 ENERGY STORAGE↗

Photo-catalytic Degradation and Sorption of Radio-cobalt from EDTA-Co Complexes Using Manganese Oxide Materials - 12220

The synthesised cryptomelane-type α-MnO{sub 2} was tested for its Co-57 uptake properties in UV-photo-reactor filled with 10 μM Co-EDTA solution with a background of 10 mM NaNO{sub 3}. High cobalt uptake of 96% was observed after 1 hour of UV irradiation. As for comparison, a well-known TiO{sub 2} (Degussa P25) was tested as reference material that showed about 92% cobalt uptake after six hours of irradiation in identical experiment conditions. It was also noted that the cobalt uptake on cryptomelane with out UV irradiation was modest, only about 10%. Decreasing the pH of the Co-EDTA solution had severe effects on the cobalt uptake mainly due to the rather high point of zero charge of the MnO{sub 2} surface (pzc at pH ∼4.5). Modifying the synthesis procedure we were able to produce a material that functioned well even in solution of pH 3 giving cobalt uptake of almost 99%. The known properties, catalytic and ion exchange, of manganese oxides were simultaneously used for the separation of EDTA complexed Co-57. Tunnel structured cryptomelane -type showed very fast and efficient Co uptake properties outperforming the well known and widely used Degussa P25 TiO{sub 2} in both counts. The layered structured manganese oxide, birnessite, reached also as high Co removal level as the reference material Degussa did but the reaction rate was considerably faster. Since the decontamination solutions are typically slightly acidic and the point of zero charge of the manganese oxides are rather high > pH 4.5 the material had to be modified. This modified material had tolerance to acidic solutions and it's Co uptake performance remained high in the solutions of lower pH (pH 3). Increasing the ion concentration of test solutions, background concentration, didn't affect the final Co uptake level; however, some changes in the uptake kinetics could be seen. The increase in EDTA/MoMO ratio was clearly reflected in the Co uptake curves. The obtained results of manganese oxide were very promising for the treatment of EDTA complexed Co solutions. The better performance values and cheaper production cost of manganese oxide, compared to titanium dioxide, is so big driving force that further studies on the material are evident. The possibilities for continuous treatment, instead of the fluidized bed -type batch experiment are investigated and the effects of other compounds affecting the de-complexation of Co-EDTA are further studied. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Findings On Minor Actinide And Lanthanide Separations Using Ion Exchange

This project seeks to determine if inorganic or hybrid inorganic ion-exchange materials can be exploited to provide effective americium and curium separations. Specifically, we seek to understand the fundamental structural and chemical factors responsible for the selectivity of the tested ion-exchange materials for actinide and lanthanide ions. During FY13, experimental work focused in the following areas: (1) investigating methods to oxidize americium in dilute nitric acid with subsequent ion-exchange performance measurements of ion exchangers with the oxidized americium and (2) synthesis, characterization and testing of ion-exchange materials. Ion-exchange materials tested included alkali titanates, alkali titanosilicates, carbon nanotubes and group(IV) metal phosphonates. Americium oxidation testing sought to determine the influence that other redox active components may have on the oxidation of Am(III).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Environmental Degradation in Advanced Reactor Environments

The Advanced Materials and Manufacturing Technologies (AMMT) program operating under the Department of Energy Office of Nuclear Energy is accelerating the qualification and deployment of additively manufactured materials in advanced reactor environments. Laser powder bed fusion (LPBF) has emerged as a promising additive manufacturing technique to fabricate complex components with the potential of tailored material properties. In the nuclear industry, metal additive manufacturing can offer numerous advantages, such as reduced lead times, streamlined quality assurance, and cost-effective low-volume production of new and replacement components with conventional or novel materials and geometries. The rapid and effective qualification of the effect of processing variability on the performance and degradation of additively manufactured materials is essential for the deployment of these components into advanced reactor environments. This talk presents an overview of the Environmental Effects area activities within AMMT. AMMT is performing irradiation and corrosion testing of several materials built by LPBF, including 316L and 316H stainless steels. Our irradiation efforts encompass neutron irradiation testing and ion irradiation testing to provide a robust technical basis for understanding the effect of process variability on materials degradation. We develop focused irradiation test plans that align well with risk-informed and technologically inclusive approaches to licensing. We will also discuss our plans and specific concerns for corrosion testing additively manufactured material, with a primary focus on molten salt and liquid sodium environments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of thermal aging and ionizing radiation on sPVC and aromatic polyether urethane used to store nuclear materials

In this work, we tested the degradation of two polymeric materials under conditions routinely encountered in nuclear applications. Polymers in the form of plastic bags are commonly used along with metal containers to store and transport nuclear materials. The role of the bag, also known as bag-out bag, is to prevent contamination in case the metal containers are breached. Polymeric materials of interest are sPVC and aromatic polyether urethane (APU-ether), which in this study were exposed to alpha, gamma and thermal conditions. These conditions were specifically chosen to simulate the harsh environments normally encountered in the storage of nuclear materials. The physical, chemical and mechanical properties of these materials were investigated by a series of characterization methods before and after exposures. Our results highlight the superior stability of APU-ether under thermal aging and ionizing radiation and provide new insights into the durability of polymeric materials used in nuclear applications. In conclusion, these findings will serve as the foundation for a rational selection of new bag-out bag materials to be considered in the nuclear industry.

36 MATERIALS SCIENCE↗

Evaluation of a Combined Cyclone and Gas Filtration System for Particulate Removal in the Gasification Process

The Wabash gasification facility, owned and operated by sgSolutions LLC, is one of the largest single train solid fuel gasification facilities in the world capable of transforming 2,000 tons per day of petroleum coke or 2,600 tons per day of bituminous coal into synthetic gas for electrical power generation. The Wabash plant utilizes Phillips66 proprietary E-Gas™ Gasification Process to convert solid fuels such as petroleum coke or coal into synthetic gas that is fed to a combined cycle combustion turbine power generation facility. During plant startup in 1995, reliability issues were realized in the gas filtration portion of the gasification process. To address these issues, a slipstream test unit was constructed at the Wabash facility to test various filter designs, materials and process conditions for potential reliability improvement. The char filtration slipstream unit provided a way of testing new materials, maintenance procedures, and process changes without the risk of stopping commercial production in the facility. It also greatly reduced maintenance expenditures associated with full scale testing in the commercial plant. This char filtration slipstream unit was installed with assistance from the United States Department of Energy (built under DOE Contract No. DE-FC26-97FT34158) and began initial testing in November of 1997. It has proven to be extremely beneficial in the advancement of the E-Gas™ char removal technology by accurately predicting filter behavior and potential failure mechanisms that would occur in the commercial process. After completing four (4) years of testing various filter types and configurations on numerous gasification feed stocks, a decision was made to investigate the economic and reliability effects of using a particulate removal gas cyclone upstream of the current gas filtration unit. A paper study had indicated that there was a real potential to lower both installed capital and operating costs by implementing a char cyclone-filtration hybrid unit in the E-Gas™ gasification process. These reductions would help to keep the E-Gas™ technology competitive among other coal-fired power generation technologies. The Wabash combined cyclone and gas filtration slipstream test program was developed to provide design information, equipment specification and process control parameters of a hybrid cyclone and candle filter particulate removal system in the E-Gas™ gasification process that would provide the optimum performance and reliability for future commercial use. The test program objectives were as follows: 1. Evaluate the use of various cyclone materials of construction; 2. Establish the optimal cyclone efficiency that provides stable long term gas filter operation; 3. Determine the particle size distribution of the char separated by both the cyclone and candle filters. This will provide insight into cyclone efficiency and potential future plant design; 4. Determine the optimum filter media size requirements for the cyclone-filtration hybrid unit; 5. Determine the appropriate char transfer rates for both the cyclone and filtration portions of the hybrid unit; 6. Develop operating procedures for the cyclone-filtration hybrid unit; and, 7. Compare the installed capital cost of a scaled-up commercial cyclone-filtration hybrid unit to the current gas filtration design without a cyclone unit, such as currently exists at the Wabash facility.

01 COAL, LIGNITE, AND PEAT↗

An Evaluation of Frangible Materials as Veneers on Vented Structural Member Designs

Literature shows there has been extensive research and testing done in the area of wall panels and frangible materials. There is evidence from past research that shows it is possible to vent a structure that has had an accidental internal explosion [1]. The reviewed literature shows that most designs vent the entire wall panel versus a frangible material attached to the wall panel. The frangible material attachment points are important to determine the overall loading of the wall panel structure [2]. The materials used in the reviewed literature were securely attached as well as strong enough to remain intact during the pressure loading to move the entire wall panel. Since the vented wall panel was the weakest part of the overall structure, the other walls of the structure were substantially larger. The structure was usually built from concrete and large amounts of steel with dirt and sand over the top of the structure.The study will be conducted at Sandia National Laboratories located in Albuquerque New Mexico. The skeletal structural design for evaluation is a rectangular frame with a square grid pattern constructed from steel. The skeletal structure has been given to the researcher as a design requirement. The grid pattern will be evaluated strictly on plastic deformation and the loading that is applied from the frangible material. The frangible material tested will either fit into the grid or will be a veneer lightly attached to the structure frame. The frangible material may be required on both sides of the structure to adequately represent the application.

36 MATERIALS SCIENCE↗

An Accelerated Testing and Analysis Framework for Qualification of Battery Materials Part I: A Case Study with LFP Cathodes

The growing demand for batteries used within automotive, aviation, and grid applications has exacerbated the need to supplement critical battery material feedstocks, such as those for anode and cathode active materials. New or supplementary material sources, however, universally comprise unique properties that can affect the lifetime and performance of resultant batteries. Even minor differences between new sources and established supplies can delay qualification, making it difficult for new suppliers to commercialize and resulting in a less resilient supply chain. Accordingly, the influence of composition, microstructure, and morphology on electrochemical performance should be characterized quickly and accurately to accelerate commercialization of new sources. This work introduces a tiered framework to assess new material viability and understand the influence of physicochemical properties on battery performance. The Tier 1 testing described here is rapid and low-effort to recognize materials with fundamental flaws and potentially disqualify them. Later testing would require more effort but provide higher-fidelity information with a goal of application-based validation. A case study examining commercial sources of LiFePO4 (LFP) is presented, using Tier 1 of the protocol to identify rapid electrochemical and physicochemical signals that correlate with performance and provide early go/no-go decisions for LFP materials without requiring long-term cycling.

25 ENERGY STORAGE↗

Cladding burst behavior of Fe-based alloys under LOCA

Burst behavior of austenitic and ferritic Fe-based alloy tubes has been examined under a simulated large break loss of coolant accident. Specifically, type 304 stainless steel (304SS) and oxidation resistant FeCrAl tubes were studied alongside Zircaloy-2 and Zircaloy-4 that are considered reference fuel cladding materials. Following the burst test, characterization of the cladding materials was carried out to gain insights regarding the integral burst behavior. Given the widespread availability of a comprehensive set of thermo-mechanical data at elevated temperatures for 304SS, a modeling framework was implemented to simulate the various processes that affect burst behavior in this Fe-based alloy. The most important conclusion is that cladding ballooning due to creep is negligible for Fe-based alloys. Thus, unlike Zr-based alloys, cladding cross-sectional area remains largely unchanged up to the point of burst. Furthermore, for a given rod internal pressure, the temperature onset of burst in Fe-based alloys appears to be simply a function of the alloy's ultimate tensile strength, particularly at high rod internal pressures.

42 ENGINEERING↗

A biosensor system using nickel ferrite nanoparticles

NiFe{sub 2}O{sub 4} ferrite nanoparticles were synthesized by chemical co-precipitation method and the structural characteristics were investigated using X-ray diffraction technique, where single cubic phase formation of nanoparticles was confirmed. The average particle size of NiFe{sub 2}O{sub 4} was found to be 4.9 nm. Nanoscale magnetic materials are an important source of labels for biosensing due to their strong magnetic properties which are not found in biological systems. This property of the material was exploited and the fabrication of the NiFe{sub 2}O{sub 4} nanoparticle based biosensor was done in the form of a capacitor system, with NiFe{sub 2}O{sub 4} as the dielectric material. The biosensor system was tested towards different biological materials with the help of electrochemical workstation and the same was analysed through Cole-Cole plot of NiFe{sub 2}O{sub 4}. The performance of the sensor was determined based on its sensitivity, response time and recovery time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crack Growth Rate and Fracture Toughness Tests on Irradiated Ex-Plant Materials

The performance of structural materials is critical for the safe and economic operation of light water reactors. Exposed to neutron irradiation during service, the reactor core internal materials can undergo significant microstructural and microchemical changes, leading to irradiation hardening and embrittlement. To ensure the structural integrity and functionality of nuclear reactor components during long-term operation, material degradation and damage mechanisms must be understood and managed adequately. In this work, irradiated materials harvested from the decommissioned Zorita reactor were studied for their cracking susceptibility and fracture resistance as a function of irradiation dose up to 47 displacement per atom (dpa). The material is a Type 304 stainless steel sectioned from the baffle plates of this pressurized water reactor with 38 years of service. Crack growth rate and fracture toughness J-resistance (J-R) curve tests were performed in low-corrosion-potential environments at ~315°C. All samples behaved similarly under cyclic loading, and no deteriorated corrosion-fatigue behavior was observed in the test environments. Under constant stress intensity factors, most samples did not show elevated crack growth rates, suggesting an adequate stress corrosion cracking resistance in the test environments. However, an unstable cracking behavior was observed in a 47-dpa sample, resulting in significantly higher crack growth rates than expected at high stress intensity factors. Crack instability was also observed in a 0.06-dpa sample but did not lead to a sustained high crack growth rate. The impact of neutron irradiation was more evident in the fracture toughness J-R curve tests. As the dose increased, the J-R curve declined considerably and became very shallow at high doses. A fully intergranular fracture morphology was also observed among the high-dose samples ruptured in an air atmosphere at room temperature. This brittle fracture mode in the absence of high temperature water environment confirmed a high degree of embrittlement of this material resulting from its service exposure to neutron irradiation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Filtration Performance Results: Sierra Peaks Material No. 4

Sandia National Laboratories (SNL) assessed the filtration performance of materials from Sierra Peaks to identify alternatives which may perform similarly to materials used in FDA-approved N95 respirators. This work is meant to characterize the aerosol performance of materials to give Sierra Peaks information for them to determine if they elect to submit masks made using these materials for follow-on N95 certification testing at an accredited facility. The R&D testbed used is a large-scale filtration system designed to test commercial filter boxes. System modifications were performed to simulate, where possible, parameters defined by the National Institute for Occupational Safety and Health (NIOSH) for certification of filter materials for N95 respirators (NIOSH 2019). The system is a pull-through design. Air enters through a Laminar Flow Element (LFE) and the volumetric flow is measured based on the pressure drop across the LFE. Pressure is measured via a Pressure Transducer (PT). The air then passes through a High Efficiency Particulate Air (HEPA) filter to purge the air of ambient airborne particulates. Test aerosol is injected into the flow shortly after and mixing is induced via a coarse mesh. The airflow is allowed to fully develop prior to arriving at the test section. The aerosol then passes through the test material mounted in a box in the test section. Pressure drop across the test article is measured and aerosol sampling probes measure the aerosol concentrations upstream and downstream of the sample. The air passes through a second HEPA filter prior to being exhausted to ambient by a blower. A Topas aerosol generator is used to produce the test aerosol from Sodium Chloride (NaC1) dissolved in deionized (DI) water. Generated aerosol passes through a heated mixing chamber and a desiccant dryer to produce nanosized solid-state particulates. A dilution loop allows for the aerosol concentration to be regulated. The aerosol sampling probes upstream and downstream of the test section are aligned with the flow path. These are ducted directly to the aerosol sizing and counting instruments. A Laser Aerosol Spectrometer (LAS) was used for data collection in the original configuration of the system and was also used for initial testing in this project. Because the lower measurement range for the LAS is 90 nanometers (nm), the LAS was switched out for a more complicated Scanning Mobility Particle Sizer (SMPS) spectrometer system. The SMPS is comprised of an Electrostatic Classifier (EC), Differential Mobility Analyzer (DMA), and a Condensation Particle Counter (CPC). This enabled data collection at 75 nm, the particle size called out in the NIOSH guidelines.

36 MATERIALS SCIENCE↗

Ultrasonic Transducer Irradiation Test Results

Ultrasonic technologies offer the potential for high-accuracy and -resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other ongoing efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. For this reason, the Pennsylvania State University (PSU) was awarded an ATR NSUF project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 10 21 n/cm 2 . The goal of this research is to characterize and demonstrate magnetostrictive and piezoelectric transducer operation during irradiation, enabling the development of novel radiation-tolerant ultrasonic sensors for use in Material Testing Reactors (MTRs). As such, this test is an instrumented lead test and real-time transducer performance data is collected along with temperature and neutron and gamma flux data. The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers. To date, one piezoelectric transducer and two magnetostrictive transducers have demonstrated reliable operation under irradiation. The irradiation is ongoing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Novel Contact Materials for Improved Performance CdTe Solar Cells Final Report

This program has explored a number of novel materials for contacts to CdTe solar cells in order to reduce the back contact Schottky barrier to zero and produce an ohmic contact. The project tested a wide range of potential contact materials including TiN, ZrN, CuInSe 2 :N, a-Si:H and alloys with C, and FeS2. Improved contacts were achieved with FeS 2 . As part of understanding the operation of the devices and controlling the deposition processes, a number of other important results were obtained. In the process of this project and following its conclusion it led to research that resulted in seven journal articles, nine conference publications, 13 talks presented at conferences, and training of eight graduate students. The seven journal articles were published in 2015, 2016, and 2017 and have been cited, as of March 2018, 52 times (one cited 19 times and two cited 11 times). We demonstrated high levels of doping of CIS with N but electrical activity of the resulting N was not high and the results were difficult to reproduce. Furthermore, even with high doping the contacts were not good. Annealing did not improve the contacts. A-Si:H was found to produce acceptable but unstable contacts, degrading even over a day or two, apparently due to H incorporation into the CdTe. Alloying with C did not improve the contacts or stability. The transition metal nitrides produced Schottky type contacts for all materials tested. While these contacts were found to be unsatisfactory, we investigated FeS 2 and found this material to be effective and comparable to the best contacts currently available. The contacts were found to be chemically stable under heat treatment and preferable to Cu doped contacts. Thus, we demonstrated an improved contact material in the course of this project. In addition, we developed new ways of controlling the deposition of CdTe and other materials, demonstrated the nature of defects in CdTe, and studied the distribution of conductivity and carrier type in CdTe devices. We demonstrated the conduction mechanism by which CdTe polycrystals improve the performance of the devices relative to single crystal devices. The mechanism shows that grain boundaries are conduction pathways for photogenerated electrons and that the corresponding holes are confined to the grains and therefore do not contribute to recombination.

14 SOLAR ENERGY↗

Summary of Gas Generation Behavior Observed in 3013 Surveillance and Monitoring Program Shelf-Life Experiments

Gas generation experiments have been conducted in small- and full-scale test containers at Los Alamos National Laboratory on samples of plutonium oxide material collected from plutonium processes across the DOE complex and tested at the bounding conditions for the Department of Energy 3013 Standard. The gas composition and pressures in the sealed experimental containers were measured over periods of months to years. These experiments have provided results for the formation and consumption of hydrogen and other gases. The conditions supporting the formation of flammable gas mixtures of hydrogen and oxygen in flammable gas mixtures were also determined. Different behaviors were observed between the materials tested based on their compositions, the stabilization performed on the material, and the post stabilization handling of the material. Many of the experiments are still ongoing. This report summarizes the results obtained for the gas generation behavior for high-purity plutonium oxides and salt-bearing impure plutonium oxides in sealed containers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary study of nuclear fuel element testing based on coded source neutron imaging

Neutron radiography (NR) is one of the most important nondestructive testing methods, which is sensitive to low density materials. Especially, Neutron transfer imaging method could be used to test radioactivity materials refraining from γ effect, but it is difficult to realize tomography. Coded source neutron imaging (CSNI) is a newly NR method developed fast in the last several years. The distance between object and detector is much longer than traditional NR, which could be used to test radioactivity materials. With pre-reconstruction process from fold-cover projections, CSNI could easily realize tomography. This thesis carries out preliminary study on the nuclear fuel element testing by coded source neutron imaging. We calculate different enrichment, flaws and activity in nuclear fuel elements tested by CSNI with Monte-Carlo simulation. The results show that CSNI could be a useful testing method for nuclear fuel element testing. (authors)

42 ENGINEERING↗

Reference Materials for Laser and Xenon Flash Thermal Diffusivity Systems

This report presents the status of current standard reference materials for thermal diffusivity testing. In most thermal properties testing systems, it is common to use standard reference materials to show the reproducibility of the tests and certify the instrument is producing results within expected uncertainty range. The definition of reference materials or standards vary depending on the quality control protocols of the project. For thermal diffusivity, although there were standards available by the National Bureau of Standards (NBS) 40 years ago, there has been no recent NIST standard reference material (SRM). There are only a few sources that produce and provide traceable reference standards for thermal diffusivity. The certificate typically expires in 5 years and only applies to the specific lot of materials. Other reference materials are provided by the testing systems manufacturers. They are mostly well-known reference materials or materials used by the equipment manufacturers with historic data. However, most these reference materials no longer carry valid certificates. Various reference materials will be discussed along with the industry practice when only secondary standards are available.

36 MATERIALS SCIENCE↗