Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

The development of optical microscopy techniques for the advancement of single-particle studies

Single particle orientation and rotational tracking (SPORT) has recently become a powerful optical microscopy tool that can expose many molecular motions. Unfortunately, there is not yet a single microscopy technique that can decipher all particle motions in all environmental conditions, thus there are limitations to current technologies. Within, the two powerful microscopy tools of total internal reflection and interferometry are advanced to determine the position, orientation, and optical properties of metallic nanoparticles in a variety of environments. Total internal reflection is an optical phenomenon that has been applied to microscopy to produce either fluorescent or scattered light. The non-invasive far-field imaging technique is coupled with a near-field illumination scheme that allows for better axial resolution than confocal microscopy and epi-fluorescence microscopy. By controlling the incident illumination angle using total internal reflection fluorescence (TIRF) microscopy, a new type of imaging probe called “non-blinking” quantum dots (NBQDs) were super-localized in the axial direction to sub-10-nm precision. These particles were also used to study the rotational motion of microtubules being propelled by the motor protein kinesin across the substrate surface. The same instrument was modified to function under total internal reflection scattering (TIRS) microscopy to study metallic anisotropic nanoparticles and their dynamic interactions with synthetic lipid bilayers. Utilizing two illumination lasers with opposite polarization directions at wavelengths corresponding to the short and long axis surface plasmon resonance (SPR) of the nanoparticles, both the in-plane and out-of-plane movements of many particles could be tracked simultaneously. When combined with Gaussian point spread function (PSF) fitting for particle super-localization, the binding status and rotational movement could be resolved without degeneracy. TIRS microscopy was also used to find the 3D orientation of stationary metallic anisotropic nanoparticles utilizing only long-axis SPR enhancement. The polarization direction of the illuminating light was rotated causing the relative intensity of p-polarized and s-polarized light within the evanescent field to change. The interaction of the evanescent field with the particles is dependent on the orientation of the particle producing an intensity curve. This curve and the in-plane angle can be compared with simulations to accurately determine the 3D orientation. Differential interference contrast (DIC) microscopy is another non-invasive far-field technique based upon interferometry that does not rely on staining or other contrast enhancing techniques. In addition, high numerical aperture condensers and objectives can be used to give a very narrow depth of field allowing for the optical tomography of samples, which makes it an ideal candidate to study biological systems. DIC microscopy has also proven itself in determining the orientation of gold nanorods in both engineered environments and within cells. Many types of nanoparticles and nanostructures have been synthesized using lithographic techniques on silicon wafer substrates. Traditionally, reflective mode DIC microscopes have been developed and applied to the topographical study of reflective substrates and the imaging of chips on silicon wafers. Herein, a laser-illuminated reflected-mode DIC was developed for studying nanoparticles on reflective surfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-situ Electrochemical Testing of Uranium Oxide Alteration under Anoxic Conditions

Prediction of the corrosion behavior of spent uranium oxide (UO 2 ) fuel is needed for developing predictive performance assessment models for a geologic repository. Currently, the Fuel Matrix Dissolution Model (FMDM) is being used for modeling UO 2 chemistry in the Engineered Barrier System (EBS) and includes the effects of oxidants, oxygen and hydrogen peroxide generated from radiolysis of the fuel in contact with water, as well as the role of hydrogen on limiting corrosion. In this report, efforts to validate the FMDM model using in-situ liquid cells in the scanning electron microscopy (SEM) are described. The System for Analysis at the Liquid Vacuum Interface (SALVI), was invented at the Pacific Northwest National Laboratory (PNNL) and is a device that enables the investigation of solid-solution systems within the electron microscope. Initial efforts have concentrated on building the testing system for radioactive materials and exploring the use of the SALVI cell on UO 2 particles.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Morphology and mixing of black carbon particles collected in central California during the CARES field study

Aerosol absorption is strongly dependent on the internal heterogeneity (mixing state) and morphology of individual particles containing black carbon (BC) and other non-absorbing species. Here, we examine an extensive microscopic data set collected in the California Central Valley during the CARES 2010 field campaign. During a period of high photochemical activity and pollution buildup, the particle mixing state and morphology were characterized using scanning transmission X-ray microscopy (STXM) at the carbon K-edge. Observations of compacted BC core morphologies and thick organic coatings at both urban and rural sites provide evidence of the aged nature of particles, highlighting the importance of highly aged particles at urban sites during periods of high photochemical activity. Based on the observation of thick coatings and more convex BC inclusion morphology, either the aging was rapid or the contribution of fresh BC emissions at the urban site was relatively small compared to background concentrations. Most particles were observed to have the BC inclusion close to the center of the host. However, host particles containing inorganic rich inclusions had the BC inclusion closer to the edge of the particle. Furthermore, these measurements of BC morphology and mixing state provide important constraints for the morphological effects on BC optical properties expected in aged urban plumes.

54 ENVIRONMENTAL SCIENCES↗

Improved microstructure of cement-based composites through the addition of rock wool particles

Rock wool is an inorganic fibrous substance produced by steam blasting and cooling molten glass. As with other industrial by-products, rock wool particles can be used as cementitious materials or ultra fine fillers in cement-based composites. This study investigated the microstructure of mortar specimens produced with cement-based composites that include various forms of rock wool particles. It conducted compressive strength testing, rapid chloride penetration tests, X-ray diffraction analysis, thermo-gravimetric analysis, and scanning electronic microscopy to evaluate the macro- and micro-properties of the cement-based composites. Test results indicate that inclusion of rock wool particles in composites improved compressive strength and reduced chloride ion penetration at the age of 91 days due to the reduction of calcium hydroxide content. Microscopic analysis confirms that the use of rock wool particles contributed to the formation of a denser, more compact microstructure within the hardened paste. In addition, X-ray diffraction analysis shows few changes in formation of pozzolanic reaction products and no new hydrations are formed with incorporating rock wool particles. - Highlights: • We report the microstructural characterization of cement-based composites. • Different mixes produced with various rock wool particles have been tested. • The influence of different mixes on macro and micro properties has been discussed. • The macro properties are included compressive strength and permeability. • XRD and SEM observations confirm the pozzolanic reaction in the resulting pastes.

36 MATERIALS SCIENCE↗

WE-H-207A-01: Computational Evaluation of High-Resolution 18F Positron Imaging Using Radioluminescence Microscopy with Lu2O3: Eu Thin-Film Scintillator

Purpose: Radioluminescence microscopy, an emerging and powerful tool for high resolution beta imaging, has been applied to molecular imaging of cellular metabolism to understand tumor biology. A novel thin-film (10 µm thickness) scintillator made of Lu{sub 2}O{sub 3}: Eu has been developed to enhance the system performance. However the advances of radioluminescence imaging with Lu{sub 2}O{sub 3}scintillator compared with that using conventional scintillator have not been explored theoretically to date. To validate the advantages of the thin-film scintillator, this study uses a novel computational simulation framework to evaluate the performance of radioluminescence microscopy using both conventional and thin-film scintillators. Methods: Numerical models for different stages of positron imaging are established. Positron from {sup 18}F passing through the scintillator and its neighbor structures are modeled by Monte-Carlo simulation using Geant4. The propagation and focus of photons by the microscope are modeled by convolution with a depth-varying point spread function generated by the Gibson-Lanni model. Photons focused on the detector plane are then captured and converted into electronic signals by an electron multiplication (EM) CCD camera, which is described by a photosensor model considering various noises and charge amplification. Results: The performance metrics of radioluminescence imaging with a thin-film Lu{sub 2}O{sub 3} and conventional CdWO{sub 4} scintillator are compared, including spatial resolution, sensitivity, positron track area and intensity. The spatial resolution of Lu{sub 2}O{sub 3} system can achieve 10 µm maximally, a 12 µm enhancement from that obtained from CdWO{sub 4} system. Meanwhile, the system with Lu{sub 2}O{sub 3} scintillator can provide a higher mean sensitivity: 40% compared with that (21.5%) obtained from CdWO{sub 4} system. Moreover, the simulation results are in good agreement with previous experimental measurements. Conclusion: This study provides a new theoretical understanding of our imaging system and has the potential to promote the development of radioluminescence microscopy for more reliable and robust application on the functional imaging of delicate biological structures. The authors acknowledge funding from NIH grant R01CA186275 and SBIR grant 1R43GM110888-01.

60 APPLIED LIFE SCIENCES↗

Fast Time-Resolved Aerosol Collector: Proof of Concept

Atmospheric particles can be collected in the field on substrates for subsequent laboratory analysis via chemically sensitive single particle methods such as scanning electron microscopy with energy dispersed x-ray analysis. With moving substrates one can achieve time resolution of seconds to minutes. We demonstrate how to increase the time resolution to a few milliseconds to provide real-time information in this paper. Our fast time-resolved aerosol collector (“Fast-TRAC”) microscopically observes the particle collection on substrate and record an on-line video. Particle arrivals are resolved to within a single frame (17 to 4 ms in this setup), and the spatial locations are matched to the subsequent single particle analysis. This approach provides real-time information on particle size and number concentration. Applications are expected in airborne studies of cloud microstructure, pollution plumes, and long term site monitoring.

54 ENVIRONMENTAL SCIENCES↗

Highlights from the Postirradiation Examination of AFC-3A and AFC-3B

Highlights from the postirradiation examination of the AFC-3A and AFC-3B irradiation test are presented. Baseline non-destructive and destructive examinations of these tests have been completed at this time. Results from visual examination, neutron radiography, gamma spectrometry, dimensional inspection, fission gas release, chemical burnup analysis, and optical microscopy have been collected. All the rodlets from these irradiations appear to have performed well during irradiation. Baseline PIE has been completed on rodlets from AFC- 3A, and AFC-3B. This includes visual exams, neutron radiography, gamma spectrometry. dimensional inspection, fission gas release evaluation, optical microscopy. microhardness evaluation. and chemical analysis. The results compiled here are a sampling of the full results. Baseline PIE provides an engineering or macroscopic scale evaluation of fuel performance and prepares samples for a more detailed phenomenological study of observed performance. Advanced PIE techniques are desired to obtain microscopic elemental and structural information both in the fuel, in the cladding, and in the interface where the composition of the FCCI layer is of great interest. The AFC-3 tests do appear to have performed roughly as designed during the irradiation. The FCCI behavior of Mo alloy metallic fuel versus Zr alloy metallic fuel has been confirmed. Results from this irradiation such as the FCCI observed in AFC-3A R1 and AFC-3A R2 can be used to eliminate Mo alloys as a choice in future irradiations where ultra-high burnup is a stated goal. Annular fuels are a preferred method for many high burnup core designs. The redistribution behavior of the annular U-Zr alloys should be studied further to better understand how this might impact high burnup annular fuel performance. The thermal bonding between annular fuel and cladding should also be studied further as there appear to be localized areas of FCCI forming in both AFC-3A R4 and AFC-3B R2, while no FCCI was observed in the Zr-based Na-bonded or Mo-based low smear density Na-bonded fuel. The performance of the low smear density. solid fuels is less clear. The neutron radiography and optical microscopy cross sections suggest the fuel is not forming a radially symmetric structure which may be causing undesirable localized temperature variations. Further study both by electron microscopy and by simulation to evaluate the implications of the non-symmetric fuel form are needed to better understand whether this fuel form merits further study under irradiation. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

p{sup +}-doping analysis of laser fired contacts for silicon solar cells by Kelvin probe force microscopy

Local rear contacts for silicon passivated emitter and rear contact solar cells can be established by point-wise treating an Al layer with laser radiation and thereby establishing an electrical contact between Al and Si bulk through the dielectric passivation layer. In this laser fired contacts (LFC) process, Al can establish a few μm thick p{sup +}-doped Si region below the metal/Si interface and forms in this way a local back surface field which reduces carrier recombination at the contacts. In this work, the applicability of Kelvin probe force microscopy (KPFM) to the investigation of LFCs considering the p{sup +}-doping distribution is demonstrated. The method is based on atomic force microscopy and enables the evaluation of the lateral 2D Fermi-level characteristics at sub-micrometer resolution. The distribution of the electrical potential and therefore the local hole concentration in and around the laser fired region can be measured. KPFM is performed on mechanically polished cross-sections of p{sup +}-doped Si regions formed by the LFC process. The sample preparation is of great importance because the KPFM signal is very surface sensitive. Furthermore, the measurement is responsive to sample illumination and the height of the applied voltage between tip and sample. With other measurement techniques like micro-Raman spectroscopy, electrochemical capacitance-voltage, and energy dispersive X-ray analysis, a high local hole concentration in the range of 10{sup 19 }cm{sup −3} is demonstrated in the laser fired region. This provides, in combination with the high spatial resolution of the doping distribution measured by KPFM, a promising approach for microscopic understanding and further optimization of the LFC process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhanced electron field emission from plasma-nitrogenated carbon nanotips

Nitrogenated carbon nanotips (NCNTPs) are synthesized by plasma-enhanced hot filament chemical vapor deposition from the hydrogen, methane, and nitrogen gas mixtures with different flow rate ratios of hydrogen to nitrogen. The morphological, structural, compositional, and electron field emission (EFE) properties of the NCNTPs were investigated by field emission scanning electron microscopy, Raman spectroscopy, x ray photoelectron spectroscopy, and EFE high-vacuum system. It is shown that the NCNTPs deposited at an intermediate flow rate ratio of hydrogen to nitrogen feature the best size/shape and pattern uniformity, the highest nanotip density, the highest nitrogen concentration, as well as the best electron field emission performance. Several factors that come into play along with the nitrogen incorporation, such as the combined effect of the plasma sputtering and etching, the transition of sp{sup 3} carbon clusters to sp{sup 2} carbon clusters, the increase of the size of the sp{sup 2} clusters, as well as the reduction of the work function, have been examined to interpret these experimental findings. Our results are highly relevant to the development of the next generation electron field emitters, flat panel displays, atomic force microscope probes, and several other advanced applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Chemical Distribution and Bonding of Lithium in Intercalated Graphite: Identification with Optimized Electron Energy Loss Spectroscopy

Direct mapping of the lithium spatial distribution and the chemical state provides critical information on structure-correlated lithium transport in electrode materials for lithium batteries. Nevertheless, probing lithium, the lightest solid element in the periodic table, poses an extreme challenge with traditional X-ray or electron scattering techniques due to its weak scattering power and vulnerability to radiation damage. Here, we report nanoscale maps of the lithium spatial distribution in electrochemically lithiated graphite using electron energy loss spectroscopy in the transmission electron microscope under optimized experimental conditions. The electronic structure of the discharged graphite was obtained from the near-edge fine structure of the Li and C K-edges and ab initio calculations. A 2.7 eV chemical shift of the Li K-edge, along with changes in the density of states, reveals the ionic nature of the intercalated lithium with significant charge transfer to the graphene sheets. Direct mapping of lithium in graphite revealed nanoscale inhomogeneities (nonstoichiometric regions), which are correlated with local phase separation and structural disorder (i.e., lattice distortion and dislocations) as observed by high-resolution transmission electron microscopy. The surface solid-electrolyte interphase (SEI) layer was also imaged and determined to have a thickness of 10-50 nm, covering both edge and basal planes with LiF as its primary inorganic component. The Li K-edge spectroscopy and mapping, combined with electron microscopy-based structural analysis provide a comprehensive view of the structure-correlated lithium intercalation in graphite and of the formation of the SEI layer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Probing Metastable Domain Dynamics via Automated Experimentation in Piezoresponse Force Microscopy

The dynamics of complex topological defects in ferroelectric materials is explored using automated experimentation in piezoresponse force microscopy. Specifically, a complex trigger system (i.e., “FerroBot”) is employed to study metastable domain-wall dynamics in Pb 0.6 Sr 0.4 TiO 3 thin films. Several regimes of superdomain wall dynamics have been identified, including smooth domain-wall motion and significant reconfiguration of the domain structures. We have further demonstrated that microscopic mechanisms of the domain-wall dynamics can be identified; i.e., domain-wall bending can be separated from irreversible domain reconfiguration regimes. In conjunction, phase-field modeling was used to corroborate the observed mechanisms. As such, the observed superdomain dynamics can provide a model system for classical ferroelectric dynamics, much like how colloidal crystals provide a model system for atomic and molecular systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

JOINT APPOINTEE: Evolution of ferroelectric properties in SmxBi1-xFeO3 via automated Piezoresponse Force Microscopy across combinatorial spread libraries

Combinatorial spread libraries offer a innovative approach to explore the evolution of material properties over broad concentration, temperature, and growth parameter spaces. However, traditional limitation of this approach is the requirement for the read-out of functional properties across the library. Here we develop automated Piezoresponse Force Microscopy (PFM) for the exploration of combinatorial spread libraries and demonstrate its application in the SmxBi1-xFeO3 system with the ferroelectric-antiferroelectric morphotropic phase boundary. This approach relies on the synergy of the quantitative nature of PFM and the implementation of automated experiments that allow PFM-based sampling over macroscopic samples. The concentration dependence of pertinent ferroelectric parameters has been determined and used to develop the mathematical framework based on Ginzburg-Landau theory describing the evolution of these properties across the concentration space. We pose that a combination of automated scanning probe microscope and combinatorial spread library approach will emerge as an efficient research paradigm to close the characterization gap in the high-throughput materials discovery. We make the data sets open to the community and hope that this will stimulate other efforts to interpret and understand the physics of these systems.

Automated Microscopy, Combinatorial Library, Ferro↗

Effects of radiation upon the light-sensing elements of the retina as characterized by scanning electron microscopy

A model system using Necturus maculosus, the common mudpuppy, was established for evaluating effects of radiation upon the light-sensing elements of the retina. Accelerated heavy ions of helium and neon from the Berkeley Bevalac were used. A number of criteria were chosen to characterize radiation damage by observing morphological changes with the scanning electron microscope. The studies indicated retina sensitivity to high-LET (neon) particles at radiation levels below 10 rads (7 particles per visual element) whereas no significant effects were seen from fast helium ions below 50 rads.

Malachowski, M. J.↗

Imaging Carbon Nanotubes in High Performance Polymer Composites via Magnetic Force Microscope

Application of carbon nanotubes as reinforcement in structural composites is dependent on the efficient dispersion of the nanotubes in a high performance polymer matrix. The characterization of such dispersion is limited by the lack of available tools to visualize the quality of the matrix/carbon nanotube interaction. The work reported herein demonstrates the use of magnetic force microscopy (MFM) as a promising technique for characterizing the dispersion of nanotubes in a high performance polymer matrix.

Lillehei, Peter T.↗

Corrosion Resistance of an AlCeMg/Stainless-Steel Reactive Bond

A major issue for metal components in many industries is corrosion as it can substantially reduce their lifetime. This issue is especially problematic for materials used in heat exchanger applications. Al–Ce–Mg alloys, which exhibit corrosion resistance and can reactively bond with other metals, may be a viable solution to this problem. This investigation studied the corrosion behavior of Al–2Ce–6Mg (atomic percent)/stainless-steel (SS) reactive bond interfaces after full immersion in nitric, sulfuric, formic, and mixed acid for 267 h. This particular Al–Ce–Mg alloy was chosen due to its good castability. The results of scanning electron microscope characterization showed that reactive bond formations repeatedly occurred throughout the length of the casting in the as-cut samples and that these formations maintained a secure bonding between the alloy and the stainless-steel tubes. Transmission electron microscopy results showed that there was a clear compositional and microstructural transition across the reactive bond. The results of the immersion tests indicated that the nitric, sulfuric, and the mixed acid did not have an observably negative effect on the reactive bond structure. As for the sample exposed to formic acid only, noticable changes were seen in both the microstructural appearance and the elemental profile across the bond, suggesting that oxide formation occurred.

Brechtl, Jamieson [ORNL] (ORCID:0000000217394283)↗

A compact multipurpose nanomanipulator for use inside a scanning electron microscope

A compact, two-stage nanomanipulator was designed and built for use inside a scanning electron microscope. It consists of a fine stage employing piezostacks that provide a 15 {mu}m range in three dimensions and a coarse stage based on commercially available stick-slip motors. Besides the fabrication of enhanced probes for scanning probe microscopy and the enhancement of electron field emitters, other novel manipulation processes were developed, such as locating, picking up, and positioning small nanostructures with an accuracy of {approx}10 nm. In combination with in situ I-V experiments, welding, and etching, this results in a multipurpose nanofactory, enabling a new range of experiments.

36 MATERIALS SCIENCE↗

Epitaxial ferromagnetic Fe{sub 3}Si on GaAs(111)A with atomically smooth surface and interface

Single crystal ferromagnetic Fe{sub 3}Si(111) films were grown epitaxially on GaAs(111)A by molecular beam epitaxy. These hetero-structures possess extremely low surface roughness of 1.3 Å and interfacial roughness of 1.9 Å, measured by in-situ scanning tunneling microscope and X-ray reflectivity analyses, respectively, showing superior film quality, comparing to those attained on GaAs(001) in previous publications. The atomically smooth interface was revealed by the atomic-resolution Z (atomic number)-contrast scanning transmission electron microscopy (STEM) images using the correction of spherical aberration (Cs)-corrected electron probe. Excellent crystallinity and perfect lattice match were both confirmed by high resolution x-ray diffraction. Measurements of magnetic property for the Fe{sub 3}Si/GaAs(111) yielded a saturation moment of 990 emu/cm{sup 3} with a small coercive field ≤1 Oe at room temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of the Durability of PEM FC Membrane Electrode Assemblies in Automotive Applications through the Fundamental Understanding of Membrane and MEA Degradation Pathways

The Project focused on mitigation of degradation processes on membrane electrode assemblies. The approach was to develop a model to improve understanding of the mechanisms, and to use it to focus mitigation strategies. The detailed effects of various accelerated stress tests (ASTs) were evaluated to determine the best subset to use in model development. A combination of ASTs developed by the Fuel Cell Commercialization Conference of Japan and the Fuel Cell Tech Team were selected for use. The ASTs were compared by measuring effects on performance, running in-situ diagnostics, and performing microscopic analyses of the membrane electrode assemblies after the stress tests were complete. Nissan ran FCCJ AST protocols and performed in situ and ex-situ electrochemical testing. DuPont ran FCTT and USFCC AST protocols, performed scanning and transmission electron microscopy and ran in-situ electrochemical tests. Other ex-situ testing was performed by IIT, along with much of the data analysis and model development. These tests were then modified to generate time-dependent data of the degradation mechanisms. Three different catalyst types and four membrane variants were then used to generate data for a theoretically-based degradation model. An important part of the approach was to use commercially available materials in the electrodes and membranes made in scalable semiworks processes rather than lab-based materials. This constraint ensured all materials would be practicable for full-scale testing. The initial model for the electrode layer was tested for internal consistency and agreement with the data. A Java-based computer application was developed to analyze the time-dependent AST data using polarization curves with four different cathode gas feeds and generate model parameters. Data showed very good reproducibility and good consistency as cathode catalyst loadings were varied. At the point of termination of the project, a basic electrode model was in hand with several areas identified for improvement. Time dependence and the membrane portion of the model were not addressed due to cancellation of Phase 2 of the Project.

08 HYDROGEN↗