Determination of two elastic constants of platelike bodies
Bending tests with plate strip in pure bending and square plate in pure shearing stress, and determination of moduli of elasticity and plate rigidity
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Bending tests with plate strip in pure bending and square plate in pure shearing stress, and determination of moduli of elasticity and plate rigidity
Explore the source record for details and available documents.
In support of an effort on damage prognosis, the viscoelastic behavior of Ti-6Al-4V (Ti-6-4) was investigated. This report documents the experimental characterization of this titanium alloy. Various uniaxial tests were conducted to low load levels over the temperature range of 20 to 538 C to define tensile, creep, and relaxation behavior. A range of strain rates (6x10(exp -7) to 0.001/s) were used to document rate effects. All tests were designed to include an unloading portion, followed by a hold time at temperature to allow recovery to occur either at zero stress or strain. The titanium alloy was found to exhibit viscoelastic behavior below the "yield" point and over the entire range of temperatures (although at lower temperatures the magnitude is extremely small). These experimental data will be used for future characterization of a viscoelastic model.
Recent developments in global seismic tomography provide three-dimensional views of S-wave structure throughout the mantle.
The through-thickness or flatwise strength of a uniaxial polymer matrix composite was investigated with several test specimen geometries and starting plate thicknesses. The use of thinner plates is desirable to save material and lower costs during materials development programs. The various configurations gave similar results with the exception of thin, straight-sided specimens. Thin specimens tended to provide invalid results per ASTM International D7291; however, the addition of a large, shallow radius improved the results. The Weibull distribution provided a good fit to the combined data.