Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Hot Topics in BaBar

The authors present recent results concerning the searches for light Higgs-like particles in the decay {Upsilon}(3S) {yields} {gamma}A{sup 0},A{sup 0} {yields} {mu}{sup +}{mu}{sup -} as well as for the lepton flavor violation in the decays {Upsilon}(3S) {yields} e{sup {+-}}{tau}{sup {-+}}, {mu}{sup {+-}}{tau}{sup {-+}} and {tau} {yields} 3l (l = e, {mu}) with the BABAR experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Collaborative Research: Equipment for and Running of the PSI MUSE Experiment

The R&D funding from this award has been a significant tool to move the Muon Scattering Experiment (MUSE) at the Paul Scherrer Institute in Switzerland forward to the stage of realization. Specifically, this award has enabled Dr. Michael Kohl and his working group at Hampton University to achieve substantial progress toward the goal of providing beam particle tracking with Gas Electron Multiplier (GEM) detectors for MUSE experiment. Establishing a particle detection system that is capable of operating in a high-intensity environment, with a data acquisition system capable of running at several kHz, combined with robust tracking software providing high efficiency for track reconstruction in the presence of noise and backgrounds will have immediate application in many other experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct optical monitoring of flow generated by bacterial flagellar rotation

We report on a highly sensitive approach to measure and quantify the time dependent changes of the flow generated by the flagella bundle rotation of single bacterial cells. This is achieved by observing the interactions between a silica particle and a bacterium, which are both trapped next to each other in a dual beam optical tweezer. In this configuration, the particle serves as a sensitive detector where the fast-Fourier analysis of the particle trajectory renders, it possible to access information about changes of bacterial activity.

60 APPLIED LIFE SCIENCES↗

Event-by-event mean p T fluctuations in pp and Pb–Pb collisions at the LHC

Event-by-event fluctuations of the mean transverse momentum of charged particles produced in pp collisions at √s = 0.9, 2.76 and 7 TeV, and Pb–Pb collisions at √ s NN = 2.76 TeV are studied as a function of the charged-particle multiplicity using the ALICE detector at the LHC. Dynamical fluctuations indicative of correlated particle emission are observed in all systems. The results in pp collisions show little dependence on collision energy. The Monte Carlo event generators PYTHIA and PHOJET are in qualitative agreement with the data. Peripheral Pb–Pb data exhibit a similar multiplicity dependence as that observed in pp. In central Pb–Pb, the results deviate from this trend, featuring a significant reduction of the fluctuation strength. The results in Pb–Pb are in qualitative agreement with previous measurements in Au–Au at lower collision energies and with expectations from models that incorporate collective phenomena.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monte Carlo Simulations of the Response of the MARIE Instrument

The MARIE instrument aboard Mars Odyssey functions as a telescope for the detection of charged, energetic, nuclei. The directionality that leads to the telescope description is achieved by requiring coincident signals in two designated detectors in MARIE s silicon detector stack for the instrument to trigger. Because of this, MARIE is actually a bi directional telescope. Triggering particles can enter the detector stack by passing through the lightly shielded front of the instrument, but can also enter the back of the instrument by passing through the bulk of Odyssey. Because of this, understanding how to relate the signals recorded by MARIE to astrophysically important quantities such as particle fluxes or spectra exterior to the spacecraft clearly requires detailed modeling of the physical interactions that occur as the particles pass through the spacecraft and the instrument itself. In order to facilitate in the calibration of the MARIE data, we have begun a program to simulate the response of MARIE using the FLUKA [1] [2] Monte Carlo radiation transport code.

Andersen, V.↗

Calibration of the electron-proton spectrometer

The principal function of the sensor used in the electron-proton spectrometer is to provide a signal which can be used to determine the energy and indicate the type of an incident particle. Two techniques are employed to resolve the particle intensity in different energy regions. The first employs a moderator surrounding each detector to provide a nominal lower limit to the energy of a particle which can be detected. The second technique utilizes a pulse height discriminator to identify those particles entering a detector whose energy is (1) sufficiently high that it exceeds the discriminator level if the particle is stopped in the detector, or (2) sufficiently low that the ionization rate causes the discrimination level to be exceeded for paths through the detector shorter than the particle range.

Cash, B. L.↗

Impact of electron lifetime on electromagnetic shower separation : Impacto do tempo de vida médio dos elétrons na separação de chuveiros eletromagnéticos

Neutrinos are superabundant particles in the universe but rarely interact with matter. Previous experiments noticed an excess of neutrinos in the low energy range that could be connected to the existence of a fourth type of neutrino: the sterile neutrino. This excess could be because of the new neutrino or just because of the incapacity of previous experiments on distinguishing electromagnetic showers initiated by electrons and photons. So, new experiments using liquid argon are being developed and bet on the liquid argon time projection chambers (LArTPCs) to find answers for these and other still open questions about these mysterious particles. LArTPCs represent today the future for neutrinos research. They have high spatial resolution and great calorimetric capacity. Many experiments are being planned using this technique; consequently, it is necessary to understand the particle’s interactions in liquid argon completely. The LArIAT experiment was created to help in the char acterization of this kind of detector’s response to charged particles that are expected to come out of neutrino interactions. The detector is exposed to a charged particle beam and receives a high number of electrons, making this a perfect experiment to help in the study of electromagnetic shower separation. To correctly identify the interactions and to collect the maximum information about them, the liquid argon that is utilized has to be ultra-pure. In this thesis, the process used on LArIAT to monitor the argon’s purity using cosmic muons is described, as well as the impact of this measurement on the separation of electromagnetic showers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A search for the higgs boson and a search for dark-matter particle with jets and missing transverse energy at collider detector at Fermilab

Finding the standard model Higgs boson and discovering beyond-standard model physics phenomena have been the most important goals for the high-energy physics in the last decades. In this thesis, we present two such searches. First is the search for the low mass standard model Higgs boson produced in association with a vector boson; second is the rst search for a dark-matter candidate (D) produced in association with a top quark (t) in particle colliders. We search in events with energetic jets and large missing transverse energy { a signature characterized by complicated backgrounds { in data collected by the CDF detector with proton-antiproton collisions at p s = 1:96 TeV. We discuss the techniques that have been developed for background modeling, for discriminating signal from background, and for reducing background resulting from detector e ects. In the Higgs search, we report the 95% con dence level upper limits on the pro- duction cross section across masses of 90 to 150 GeV/c2. The expected limits are improved by an average of 14% relative to the previous analysis. The Large Hadron Collider experiments reported a Higgs-like particle with mass of 125 GeV/c2 by study- ing the data collected in year 2011/12. At a Higgs boson mass of 125 GeV/c2, our observed (expected) limit is 3.06 (3.33) times the standard model prediction, corre- sponding to one of the most sensitive searches to date in this nal state. In the dark matter search, we nd the data are consistent with the standard model prediction, thus set 95% con dence level upper limits on the cross section of the process p p ! t + D as a function of the mass of the dark-matter candidate. The xviii upper limits are approximately 0.5 pb for a dark-matter particle with masses in the range of 0 􀀀 150 GeV/c2.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deep-Learning based Reconstruction of the Shower Maximum $X_{\mathrm{max}}$ using the Water-Cherenkov Detectors of the Pierre Auger Observatory

The atmospheric depth of the air shower maximum X max is an observable commonly used for the determination of the nuclear mass composition of ultra-high energy cosmic rays. Direct measurements of X max are performed using observations of the longitudinal shower development with fluorescence telescopes. At the same time, several methods have been proposed for an indirect estimation of X max from the characteristics of the shower particles registered with surface detector arrays. In this paper, we present a deep neural network (DNN) for the estimation of X max . The reconstruction relies on the signals induced by shower particles in the ground based water-Cherenkov detectors of the Pierre Auger Observatory. The network architecture features recurrent long short-term memory layers to process the temporal structure of signals and hexagonal convolutions to exploit the symmetry of the surface detector array. We evaluate the performance of the network using air showers simulated with three different hadronic interaction models. Thereafter, we account for long-term detector effects and calibrate the reconstructed X max using fluorescence measurements. Finally, we show that the event-by-event resolution in the reconstruction of the shower maximum improves with increasing shower energy and reaches less than 25 g/cm 2 at energies above 2 × 10 19 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First-ever deployment of a SiPM-on-tile calorimeter in a collider: a parasitic test with 200 GeV p p collisions at RHIC.

We describe the testing of a prototype SiPM-on-tile iron-scintillator calorimeter at the Relativistic Heavy Ion Collider (RHIC) during its 200 GeV p p run in 2024. The prototype, measuring 20 × 20 cm 2 and 24 radiation lengths in depth, was positioned in the STAR experimental hall, approximately 8 m from the interaction point and 65 cm from the beam line, covering a pseudorapidity range of about 3.1 < η < 3.4. By using the dark current of a reference SiPM as a radiation monitor, we estimate that the prototype was exposed to a fluence of about 10 10 1-MeV n eq /cm 2 . Channel-by-channel calibration was performed in a data-driven way with the signature from minimum-ionizing particles during beam-on conditions. AGeant4 detector simulation, with inputs from thePythia8 event generator, describes measurements of energy spectra and hit multiplicities reasonably well. These results mark the first deployment, commissioning, calibration, and long-term operation of a SiPM-on-tile calorimeter in a collider environment. This experimental campaign will guide detector designs and operational strategies for the ePIC detector at the future EIC, as well as other applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for heavy particles decaying into top-quark pairs using lepton-plus-jets events in proton–proton collisions at $\sqrt{s} = 13$ $\text {TeV}$ with the ATLAS detector

Here, a search for new heavy particles that decay into top-quark pairs is performed using data collected from proton–proton collisions at a centre-of-mass energy of 13 TeV by the ATLAS detector at the Large Hadron Collider. The integrated luminosity of the data sample is 36.1 fb –1 . Events consistent with top-quark pair production are selected by requiring a single isolated charged lepton, missing transverse momentum and jet activity compatible with a hadronic top-quark decay. Jets identified as likely to contain b-hadrons are required to reduce the background from other Standard Model processes. The invariant mass spectrum of the candidate top-quark pairs is examined for local excesses above the background expectation. No significant deviations from the Standard Model predictions are found. Exclusion limits are set on the production cross-section times branching ratio for hypothetical Z' bosons, Kaluza–Kein gluons and Kaluza–Klein gravitons that decay into top-quark pairs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for long-lived, massive particles in events with displaced vertices and missing transverse momentum in s = 13 TeV p p collisions with the ATLAS detector

A search for long-lived, massive particles predicted by many theories beyond the Standard Model is presented. Here, the search targets final states with large missing transverse momentum and at least one high-mass displaced vertex with five or more tracks, and uses 32.8 fb -1 of $\sqrt s = 13$ TeV pp collision data collected by the ATLAS detector at the LHC. The observed yield is consistent with the expected background. The results are used to extract 95% C.L. exclusion limits on the production of long-lived gluinos with masses up to 2.37 TeV and lifetimes of O (10 - 2 ) - O (10) ns in a simplified model inspired by split supersymmetry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searching for Sterile Neutrinos In the NOvA Experiment and Measurements of Hadronic Energy Response with NOvA Test Beam Data

The NOvA (NuMI Off-Axis electron neutrino Appearance) experiment is a long-baseline neutrino oscillation experiment composed of two functionally identical detectors: a 300-ton Near Detector and a 14-kton Far Detector, separated by 809 km and placed 14 mrad off the axis of the NuMI neutrino beam created at Fermilab. This configuration enables NOvA’s rich neutrino physics program, which includes measuring neutrino mixing parameters, determining the neutrino mass hierarchy, probing CP violation in the leptonic sector, studying neutrino cross sections, searching for sterile neutrinos, and more.\\ In this thesis I will present two independent analyses developed within the NOvA experiment. The first is a search for light sterile neutrino oscillations in the 3+1 framework using $\nu_\mu$-CC and NC samples from the NOvA Near and Far Detectors. Light sterile neutrinos are hypothetical neutral leptons that do not participate in the weak interactions but can mix with the three known active neutrinos: $\nu_e$, $\nu_\mu$, and $\nu_\tau$. Anomalous results, such as $\nu_e$/$\bar{\nu}e$ appearance in a $\nu_\mu$ ($\bar{\nu}_\mu$) beam observed by the MiniBooNE and LSND experiments, can be explained by the existence of sterile neutrinos. Thus, proving the existence of this type of neutrino is essential. The latest results of these searches in the NOvA experiment, along with contributions to this effort, will be presented.\\ The second is the first measurement of the pion energy response using data from the NOvA Test Beam experiment. The NOvA Test Beam experiment, deployed at Fermilab, uses a scaled-down 30-ton NOvA detector to analyze tagged beamline particles. The beamline can select and identify electrons, muons, pions, kaons, and protons with momenta ranging from 0.4 to 1.4 GeV/c. Pions are an important component of the hadronic system in neutrino interactions, and understanding how the detector responds to these particles is crucial for the validation of the simulation and the reduction of detector calibration uncertainties, which remain one of the largest systematic uncertainties in NOvA analyses.

Dueñas Tonguino, David Francisco [Cincinnati U.] (↗

Charged-particle multiplicities in p p interactions at s = 900 GeV measured with the ATLAS detector at the LHC

CERN-LHC. Measurement of the charged particle mulitplicity and its depenedence on pseudorapidity and transverse momentum in P P collisions at a centre-of-mass energy of 900 GeV. The data were taken during the period December 2009 with an approximate total integrated luminosity of 9 mub-1 and cover the pseudorapidity range -2.5 to 2.5 with charged particle transverse momenta > 0.5 GeV. Numerical values supplied by G. Brandt.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for new particles in events with a hadronically decaying W or Z boson and large missing transverse momentum at $\sqrt{s}$ = 13 TeV using the ATLAS detector

A search is presented for new particles produced in proton-proton collisions at a centre-of-mass energy of 13 TeV that result in final states comprising a massive vector ( W or Z ) boson that decays hadronically and large missing transverse momentum. The data sample was collected with the ATLAS experiment at the Large Hadron Collider from 2015 to 2018 and corresponds to an integrated luminosity of 140 fb - 1 . No significant excess over the Standard Model expectation is observed. Model-independent 95% confidence-level limits on the visible cross-section that range from 0.3 fb to 79.5 fb are obtained for non-Standard-Model processes. Exclusion limits are also presented for models with axion-like particles, for two-Higgs-doublet models with a pseudo-scalar mediator between the Standard Model and the dark sector, for the invisible decay of the Higgs boson and for pair-produced weakly interacting dark matter candidates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-shot ionization-based monitor for pulsed electron beams

In this work, we present an experimental demonstration of a single-shot, nondestructive electron beam diagnostic based on the ionization of a low-density pulsed gas jet. In our study, 7 MeV electron bunches from a radio-frequency photoinjector, carrying up to 100 pC of charge, traversed a localized distribution of nitrogen gas (N 2 ). The interaction of the electron bunches with the N 2 gas generated a correlated signature in the ionized particle distribution, which was spatially magnified using a series of electrostatic lenses and recorded with a microchannel-plate detector. Various modalities, including point-to-point imaging and velocity mapping, are investigated. A temporal trace of the detector current enabled the identification of single- and double-ionization events. The characteristics of the ionization distribution, dependence on gas density, total bunch charge, and other parameters, are described. Approaches to scaling to higher electron bunch density and energy are suggested. Additionally, the instrument proves useful for comprehensive studies of the ionization process itself.

47 OTHER INSTRUMENTATION↗