Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Dynamic characterization and performance evaluation of a 10-kW power take-off with mechanical motion rectifier for wave energy conversion

The power take-off (PTO) is a key component for wave energy converters. In this paper, a compact PTO with mechanical motion rectification rated at 10 kW is designed and prototyped, and characterized. A piecewise nonlinear dynamic model is established to describe its unique dynamic property. A linear hydraulic actuator is adopted in lab testing to drive the prototype and the unknown parameters of the dynamic model are identified. Further verification shows that the model can predict the dynamic performance of the PTO well. The test results show that the mechanical motion rectifier-based PTO can achieve overall energy transfer efficiency as high as 65% in regular waves even when the generator is working below the rated electric load and speed. In the irregular wave test, the PTO achieved the overall energy transfer efficiency of 54%, and the peak-to-average ratio acquired during the test is 12.5.

16 TIDAL AND WAVE POWER↗

Fundamental Limitations Of Passive Power Dividers

Report presents novel theoretical analysis of performance of passive, multiport power dividers like those used to distribute power to radiating elements of array antennas. Typically, unit cell of power-divider network is three- or four-port subnetwork with one port terminated, and subnetworks of network cascaded in multiple layers, so that insertion losses are of major concern.

Antsos, Dimitrios↗

Impedance Matching a Quarter Wave Resonant Receiver to Improve Efficiency in Unipolar Capacitive Wireless Power Transfer

Impedance matching techniques to achieve high performance in conventional wireless power transfer (WPT) systems are well established. These WPT systems are modelled as a lumped circuit, where the voltages/currents are approximately uniform and mostly unaffected by parasitic elements. However, a group of WPT techniques exist that utilize parasitic elements to form a highly resonant power transfer condition at high quality factors, exploiting a distributed circuit operation that can be modeled as a mutually coupled transmission line. A calculated matching network typically becomes unmatched when connected to the transmission line, as it changes the electrical structure of the coupled transmission line. This is particularly true for WPT systems that use quarter wave (QWR) or half wave resonators (HWR) for the receiver. Here we present one technique of matching to a mutually coupled transmission line where a parallel path is formed that improves the power transfer efficiency without severely altering the transmission line characteristics.

Wireless↗

Dynamic Characterization and Performance Evaluation of a 10-kw Power Take-Off with Mechanical Motion Rectifier for Wave Energy Conversion

The power take-off (PTO) is a key component for wave energy converters (WECs). The dynamic properties of the PTO influence the response of the WEC and should be considered when designing the WEC and not oversimplified. In addition, the efficiency as well as the reliability can play an important role on whether the PTO can be suitable for real-world applications. In this paper, a novel compact PTO rated at 10 kW is designed and prototyped, and a comprehensive nonlinear dynamic model is established for the PTO. Through bench testing, the unknown parameters of the dynamic model are characterized and determined. Further verification shows that the model can predict the dynamic performance of the PTO well. In addition, the test results show that the mechanical motion rectifier PTO can achieve good energy transfer efficiency, especially for low-load and low-speed conditions.

bench test↗

Scaling magnetized liner inertial fusion on Z and future pulsed-power accelerators

The MagLIF (Magnetized Liner Inertial Fusion) concept [S. A. Slutz et al., Phys. Plasmas 17, 056303 (2010)] has demonstrated fusion–relevant plasma conditions [M. R. Gomez et al., Phys. Rev. Lett. 113, 155003 (2014)] on the Z accelerator with a peak drive current of about 18 MA. We present 2D numerical simulations of the scaling of MagLIF on Z as a function of drive current, preheat energy, and applied magnetic field. The results indicate that deuterium-tritium (DT) fusion yields greater than 100 kJ could be possible on Z when all of these parameters are at the optimum values: i.e., peak current = 25 MA, deposited preheat energy = 5 kJ, and B{sub z} = 30 T. Much higher yields have been predicted [S. A. Slutz and R. A. Vesey, Phys. Rev. Lett. 108, 025003 (2012)] for MagLIF driven with larger peak currents. Two high performance pulsed-power accelerators (Z300 and Z800) based on linear-transformer-driver technology have been designed [W. A. Stygar et al., Phys. Rev. ST Accel. Beams 18, 110401 (2015)]. The Z300 design would provide 48 MA to a MagLIF load, while Z800 would provide 65 MA. Parameterized Thevenin-equivalent circuits were used to drive a series of 1D and 2D numerical MagLIF simulations with currents ranging from what Z can deliver now to what could be achieved by these conceptual future pulsed-power accelerators. 2D simulations of simple MagLIF targets containing just gaseous DT have yields of 18 MJ for Z300 and 440 MJ for Z800. The 2D simulated yield for Z800 is increased to 7 GJ by adding a layer of frozen DT ice to the inside of the liner.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Situational Awareness of Grid Anomalies (SAGA) for Visual Analytics—Near-Real-Time Cyber-Physical Resiliency Through Machine Learning

The Situational Awareness of Grid Anomalies (SAGA) project built upon foundational power system tools developed at the National Renewable Energy Laboratory (NREL) integrated with an ever-increasing set of Gridmetrics data extracted from the cable television (CATV) broadband network infrastructure while assimilating other time-series geospatial data and information, such as weather and cyber-physical phenomena, to demonstrate a disruptive technology for power system data analytics relying on existing infrastructure. Three research thrusts supported (1) visual analytics, (2) cyber-physical power system simulation, and (3) anomaly detection. SAGA created technology that leverages, couples, and fortifies two vastly different realms - power and broadband - to increase the resiliency of the power grid in the face of increasing cyberattacks and operational challenges related to integrating DERs. The exploration of potential synergies of broadband-enabled grids resulted in identifying a mutually beneficial symbiosis that can increase the resiliency of both power and broadband services. Broadband networks perform better with reliable power and are good at providing real-time measurements that identify where the grid is under attack, is failing, or is weak. Likewise, sensor-starved distribution grids perform better and can be more reliable when their operation is buttressed with observations of broadband-detected anomalies. Future research can explore broadband's contribution to continuing to improve grid resiliency, reliability, and cost-effective operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Testing of an Integrated Magnetic Power Take-Off

A wave energy converter (WEC) and the power take-off (PTO) generator system can be represented by using a mass-spring-dampener model. By incorporating a negative stiffness spring within the PTO, the overall stiffness of the PTO can be lowered allowing the impedance of the PTO to be more closely matched with the WEC. By designing for impedance matching the WEC can greatly enhance its power generation capability. This project has involved the design, fabrication and testing of a new type of linear-stroke length and rotary stroke length adjustable negative stiffness magnetic springs for use within a wave energy converter (WEC). The magnetic springs were studied by using 3-D finite element analysis with the objective of creating high energy density and a long linear stroke length. After the construction and testing of both a proof-of-principle adjustable linear and rotary magnetic spring prototype the rotary (torsional) magnetic spring was selected for scaling up analysis. The selected scaled-up proof-of-principle magnetic spring had a peak torque of 850 Nm with a ±45 degree stroke length. By translating the inner rotor relative to the outer rotor, the stiffness could be adjusted to be either negative or positive stiffness. During this project a magnetic lead screw was also studied, and it was shown that by combining the magnetic lead screw with a linearly translating magnetic spring a very long rotary stroke length could be attained. However, as the magnetic lead screw increased complexity and reduced overall energy density relative to a rotary (torsional) spring, this design approach was not further pursed. Dynamometer testing of the variable stiffness magnetic springs was first completed by Portland State University and following this the magnetic spring performance was independently verified by Sandia National Laboratory (Sandia). A WEC analysis when using a variable stiffness magnetic spring was completed by using the WecOptTool. WecOptTool is an open-source WEC optimization software developed by Sandia that supports efficient power take-off (PTO) and control optimization. Wave condition data from the Oregon PacWave test-site was used in this study. The analysis showed that a WEC with a tunable stiffness value could consistently achieve about 80% of its maximum theoretical power production. The use of a tunable stiffness WEC, rather than zero-stiffness or a constant stiffness WEC was also shown to lead to a smaller maximum PTO force requirement. The variable stiffness magnetic spring was integrated into an experimental WEC developed by Sandia, called a Wave-Bot. Sandia successfully completed water-tank testing of the Wave-Bot at the Navy’s Carderock, Maryland, wave-basin test site. The wave-basin testing helped to experimentally demonstrate the operating capabilities and increased power generation capability of a WEC containing an integrated variable stiffness magnetic spring. A WEC capacity factor analysis was also completed. The capacity factor was defined as the ratio of annual average WEC generator power to the maximum (RMS) generated power. This capacity factor provided a means of identifying the ratio of potential revenue to cost. It was calculated that if a tunable variable stiffness magnetic spring has RMS constraints it could operate with a capacity factor above 30%. This is comparable to a wind turbine’s capacity factor.

16 TIDAL AND WAVE POWER↗

In Space Nuclear Power as an Enabling Technology for Deep Space Exploration

Deep Space Exploration missions, both for scientific and Human Exploration and Development (HEDS), appear to be as weight limited today as they would have been 35 years ago. Right behind the weight constraints is the nearly equally important mission limitation of cost. Launch vehicles, upper stages and in-space propulsion systems also cost about the same today with the same efficiency as they have had for many years (excluding impact of inflation). Both these dual mission constraints combine to force either very expensive, mega systems missions or very light weight, but high risk/low margin planetary spacecraft designs, such as the recent unsuccessful attempts for an extremely low cost mission to Mars during the 1998-99 opportunity (i.e., Mars Climate Orbiter and the Mars Polar Lander). When one considers spacecraft missions to the outer heliopause or even the outer planets, the enormous weight and cost constraints will impose even more daunting concerns for mission cost, risk and the ability to establish adequate mission margins for success. This paper will discuss the benefits of using a safe in-space nuclear reactor as the basis for providing both sufficient electric power and high performance space propulsion that will greatly reduce mission risk and significantly increase weight (IMLEO) and cost margins. Weight and cost margins are increased by enabling much higher payload fractions and redundant design features for a given launch vehicle (higher payload fraction of IMLEO). The paper will also discuss and summarize the recent advances in nuclear reactor technology and safety of modern reactor designs and operating practice and experience, as well as advances in reactor coupled power generation and high performance nuclear thermal and electric propulsion technologies. It will be shown that these nuclear power and propulsion technologies are major enabling capabilities for higher reliability, higher margin and lower cost deep space missions design to reliably reach the outer planets for scientific exploration.

Sackheim, Robert L.↗

A Double-side Cooled SiC MOSFET Power Module with Sintered-silver Interposers: I. Design, Simulation, Fabrication, and Performance Characterization

Planar, double-side cooled power modules are emerging in electric-drive inverters because of their low profile, better heat extraction, and lower package parasitic inductances. However, there is still concern about their reliability due to the rigid interconnection between the device chips and two substrates of the power module. In this paper, a porous interposer made of low-temperature sintered silver is introduced to reduce the thermo-mechanical stresses in the module. A double-side cooled half-bridge module consisting of two 1200 V, 149 A SiC MOSFETs was designed, fabricated, and characterized. By using the sintered-Ag instead of solid copper interposers, our simulation results showed that at a total power loss of 200 W, the thermo-mechanical stress at the most vulnerable interfaces (interposer-attach layer) was reduced by 42 % and in the SiC MOSFET by 50 % with a trade-off of only 3.6 % increase in junction temperature. The sintered-Ag interposers were readily fabricated into desired dimensions without post-machining and did not require any surface finishing for die-bonding and substrate interconnection by silver sintering. Here, the porous interposers were also deformable under a low force or pressure, which helped to accommodate chip thickness and/or substrate-to-substrate gap variations in the planar module structure, thus simplifying module fabrication. Experimental results on the electrical performance of the fabricated SiC modules validated the success of using the porous silver interposers for fabricating planar, double-side cooled power modules.

42 ENGINEERING↗

Design and Off-design Performance of 100 Kwe-class Brayton Power Conversion Systems

The NASA Glenn Research Center in-house computer model Closed Cycle Engine Program (CCEP) was used to explore the design trade space and off-design performance characteristics of 100 kWe-class recuperated Closed Brayton Cycle (CBC) power conversion systems. Input variables for a potential design point included the number of operating units (1, 2, 4), cycle peak pressure (0.5, 1, 2 MPa), and turbo-alternator shaft speed (30, 45, 60 kRPM). The design point analysis assumed a fixed turbine inlet temperature (1150 K), compressor inlet temperature (400 K), working-fluid molecular weight (40 g/mol), compressor pressure ratio (2.0), recuperator effectiveness (0.95), and a Sodium-Potassium (NaK) pumped-loop radiator. The design point options were compared on the basis of thermal input power, radiator area, and mass. For a nominal design point with defined Brayton components and radiator area, off-design cases were examined by reducing turbine inlet temperature (as low as 900 K), reducing shaft speed (as low as 50% of nominal), and circulating a percentage (up to 20%) of the compressor exit flow back to the gas cooler. The off-design examination sought approaches to reduce thermal input power without freezing the radiator.

Johnson, Paul K.↗

Design and Off-Design Performance of 100 kWe-Class Brayton Power Conversion Systems

The NASA Glenn Research Center in-house computer model Closed Cycle Engine Program (CCEP) was used to explore the design trade space and off-design performance characteristics of 100 kWe-class recuperated Closed Brayton Cycle (CBC) power conversion systems. Input variables for a potential design point included the number of operating units (1, 2, 4), cycle peak pressure (0.5, 1, 2 MPa), and turbo-alternator shaft speed (30, 45, 60 kRPM). The design point analysis assumed a fixed turbine inlet temperature (1150 K), compressor inlet temperature (400 K), helium-xenon working-fluid molecular weight (40 g/mol), compressor pressure ratio (2.0), recuperator effectiveness (0.95), and a Sodium-Potassium (NaK) pumped-loop radiator. The design point options were compared on the basis of thermal input power, radiator area, and mass. For a nominal design point with defined Brayton components and radiator area, off-design cases were examined by reducing turbine inlet temperature (as low as 900 K), reducing shaft speed (as low as 50 percent of nominal), and circulating a percentage (up to 20 percent) of the compressor exit flow back to the gas cooler. The off-design examination sought approaches to reduce thermal input power without freezing the radiator.

Johnson, Paul K.↗

Hybrid Power Management-Based Vehicle Architecture

Hybrid Power Management (HPM) is the integration of diverse, state-of-the-art power devices in an optimal configuration for space and terrestrial applications (s ee figure). The appropriate application and control of the various power devices significantly improves overall system performance and efficiency. The basic vehicle architecture consists of a primary power source, and possibly other power sources, that provides all power to a common energy storage system that is used to power the drive motors and vehicle accessory systems. This architecture also provides power as an emergency power system. Each component is independent, permitting it to be optimized for its intended purpose. The key element of HPM is the energy storage system. All generated power is sent to the energy storage system, and all loads derive their power from that system. This can significantly reduce the power requirement of the primary power source, while increasing the vehicle reliability. Ultracapacitors are ideal for an HPM-based energy storage system due to their exceptionally long cycle life, high reliability, high efficiency, high power density, and excellent low-temperature performance. Multiple power sources and multiple loads are easily incorporated into an HPM-based vehicle. A gas turbine is a good primary power source because of its high efficiency, high power density, long life, high reliability, and ability to operate on a wide range of fuels. An HPM controller maintains optimal control over each vehicle component. This flexible operating system can be applied to all vehicles to considerably improve vehicle efficiency, reliability, safety, security, and performance. The HPM-based vehicle architecture has many advantages over conventional vehicle architectures. Ultracapacitors have a much longer cycle life than batteries, which greatly improves system reliability, reduces life-of-system costs, and reduces environmental impact as ultracapacitors will probably never need to be replaced and disposed of. The environmentally safe ultracapacitor components reduce disposal concerns, and their recyclable nature reduces the environmental impact. High ultracapacitor power density provides high power during surges, and the ability to absorb high power during recharging. Ultracapacitors are extremely efficient in capturing recharging energy, are rugged, reliable, maintenance-free, have excellent lowtemperature characteristic, provide consistent performance over time, and promote safety as they can be left indefinitely in a safe, discharged state whereas batteries cannot.

Eichenberg, Dennis J.↗

Controlled impact demonstration on-board (interior) photographic system

Langley Research Center (LaRC) was responsible for the design, manufacture, and integration of all hardware required for the photographic system used to film the interior of the controlled impact demonstration (CID) B-720 aircraft during actual crash conditions. Four independent power supplies were constructed to operate the ten high-speed 16 mm cameras and twenty-four floodlights. An up-link command system, furnished by Ames Dryden Flight Research Facility (ADFRF), was necessary to activate the power supplies and start the cameras. These events were accomplished by initiation of relays located on each of the photo power pallets. The photographic system performed beyond expectations. All four power distribution pallets with their 20 year old Minuteman batteries performed flawlessly. All 24 lamps worked. All ten on-board high speed (400 fps) 16 mm cameras containing good resolution film data were recovered.

May, C. J.↗

Preliminary Cost and Performance Results for a Natural Gas-Fired Direct sCO2 Power Plant

<p class="cs5F0F80D8"><span>This study reports on a cost and performance baseline developed at NETL for a natural gas-fueled direct sCO2 plant, which holds promise as an efficient, cost-effective method of power production with carbon capture and storage (CCS).&nbsp; The steady state plant model includes turbine cooling flows based on a semi-empirical cooling model, and thermal integration with the air separation unit and oxygen compression train.&nbsp; Discussion of the performance of the baseline plant design is followed by details on the costing methodology, overall plant capital cost, and resulting cost of electricity (COE).&nbsp; Performance results yield a baseline sCO2 plant thermal efficiency of 48.2% (HHV) with 98.2% carbon capture, an improvement over the reference NGCC plant with CCS (45.7% and 90.7% carbon capture).&nbsp; Cost analyses yield a 5% reduction in COE versus the NGCC plant, albeit with significant uncertainty.&nbsp; Finally, the effects of incomplete combustion on the overall plant performance are assessed.</span>

White, Chuck↗

Preliminary Cost and Performance Results for a Natural Gas-Fired Direct sCO2 Power Plant

<span>This study reports on a cost and performance baseline developed at NETL for a natural gas-fueled direct sCO2 plant, which holds promise as an efficient, cost-effective method of power production with carbon capture and storage (CCS).&nbsp; The steady state plant model includes turbine cooling flows based on a semi-empirical cooling model, and thermal integration with the air separation unit and oxygen compression train.&nbsp; Discussion of the performance of the baseline plant design is followed by details on the costing methodology, overall plant capital cost, and resulting cost of electricity (COE).&nbsp; Performance results yield a baseline sCO2 plant thermal efficiency of 48.2% (HHV) with 98.2% carbon capture, an improvement over the reference NGCC plant with CCS (45.7% and 90.7% carbon capture).&nbsp; Cost analyses yield a 5% reduction in COE versus the NGCC plant, albeit with significant uncertainty.&nbsp; Finally, the effects of incomplete combustion on the overall plant performance are assessed.</span>

Weiland, Nathan↗

Carbon-Nanotube-Based Electrochemical Double-Layer Capacitor Technologies for Spaceflight Applications

Electrochemical double-layer capacitors, or supercapacitors, have tremendous potential as high-power energy sources for use in low-weight hybrid systems for space exploration. Electrodes based on single-wall carbon nanotubes (SWCNTs) offer exceptional power and energy performance due to the high surface area, high conductivity, and the ability to functionalize the SWCNTs to optimize capacitor properties. This paper will report on the preparation of electrochemical capacitors incorporating SWCNT electrodes and their performance compared with existing commercial technology. Preliminary results indicate that substantial increases in power and energy density are possible. The effects of nanotube growth and processing methods on electrochemical capacitor performance is also presented. The compatibility of different SWCNTs and electrolytes was studied by varying the type of electrolyte ions that accumulate on the high-surface-area electrodes.

Arepalli, S.↗

Multimegawatt nuclear electric propulsion - First order system design and performance evaluation

The development of space nuclear power supplies capable of delivering high levels of power (1 to 10 MWe) for long life (5 to 10 years) is being considered. An important potential application of these systems will be to provide power for advanced electric propulsion devices such as ion thrusters or Magneto-Plasma-Dynamic (MPD) thrusters. High-powered Nuclear Electric Propulsion (NEP) concepts based on both ion and MPD thrusters are reviewed. To allow for mission performance evaluation, power supply, power processing, and thruster subsystems are characterized for both ion and MPD propulsion systems designed for operation in the 1 to 10 MWe power range. Several proposed missions which are significantly enhanced by the performance potential of these devices are investigated. Studied missions include near-earth orbit raising, cis-lunar cargo transportation, and planetary exploration. If developed, these 1 to 10 MWe NEP systems may provide a technological base for the development of even larger propulsion systems with power levels of up to hundreds of megawatts. The potential performance and technologies associated with such ultra-high-powered NEP systems is explored.

Sercel, J. C.↗