Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

3-Dimensional Magnetic Resonance Spectroscopic Imaging at 3 Tesla for Early Response Assessment of Glioblastoma Patients During External Beam Radiation Therapy

Purpose: To evaluate the utility of 3-dimensional magnetic resonance (3D-MR) proton spectroscopic imaging for treatment planning and its implications for early response assessment in glioblastoma multiforme. Methods and Materials: Eighteen patients with newly diagnosed, histologically confirmed glioblastoma had 3D-MR proton spectroscopic imaging (MRSI) along with T2 and T1 gadolinium-enhanced MR images at simulation and at boost treatment planning after 17 to 20 fractions of radiation therapy. All patients received standard radiation therapy (RT) with concurrent temozolomide followed by adjuvant temozolomide. Imaging for response assessment consisted of MR scans every 2 months. Progression-free survival was defined by the criteria of MacDonald et al. MRSI images obtained at initial simulation were analyzed for choline/N-acetylaspartate ratios (Cho/NAA) on a voxel-by-voxel basis with abnormal activity defined as Cho/NAA ≥2. These images were compared on anatomically matched MRSI data collected after 3 weeks of RT. Changes in Cho/NAA between pretherapy and third-week RT scans were tested using Wilcoxon matched-pairs signed rank tests and correlated with progression-free survival, radiation dose and location of recurrence using Cox proportional hazards regression. Results: After a median follow-up time of 8.6 months, 50% of patients had experienced progression based on imaging. Patients with a decreased or stable mean or median Cho/NAA values had less risk of progression (P<.01). Patients with an increase in mean or median Cho/NAA values at the third-week RT scan had a significantly greater chance of early progression (P<.01). An increased Cho/NAA at the third-week MRSI scan carried a hazard ratio of 2.72 (95% confidence interval, 1.10-6.71; P=.03). Most patients received the prescription dose of RT to the Cho/NAA ≥2 volume, where recurrence most often occurred. Conclusion: Change in mean and median Cho/NAA detected at 3 weeks was a significant predictor of early progression. The potential impact for risk-adaptive therapy based on early spectroscopic findings is suggested.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-18: A New Approach To Cancer Treatment

Purpose: To assess the correlation between mean lethal radiation doses (Do) with NMR water proton spin lattice relaxation time (T1) in different phases of Hela cells. Methods: Analysis of T1 with Do was assessed in M, G1, G2 and S-phase at energies of 220 kVp, 280 kVp and 1.25 MeV (Co-60). Results: T1 against Do in M, G1, G2, and S phase at 220 kVp yield a correlation of 0.80. At 280 kVp and 1.25 MeV the correlation is 0.77 and 0.82 respectively. Conclusion: It appears that T1 value decreases from M phase (1020 ± 84 ms) to S phase (534 ± 43 ms). The Do values increases from M phase to S phase. The variation in T1 and Do in different phases of the cell cycles provide a clue to time the mitotic phase at the radiation treatment time. It appears that T1 value decreases from M phase (1020 ± 84 ms) to S phase (534 ± 43 ms). The Do values increases from M phase to S phase. The variation in T1 and Do in different phases of the cell cycles provide a clue to time the mitotic phase at the radiation treatment time.

60 APPLIED LIFE SCIENCES↗

SU-G-BRC-04: Collimator Angle Optimization in Volumetric Modulated Arc Therapy

Purpose: Volumetric modulated arc therapy (VMAT) has revolutionized radiation treatment by decreasing treatment time and monitor units, thus reducing scattered and whole body radiation dose. As the collimator angle changes the apparent leaf gap becomes larger which can impact plan quality, organ at risk (OAR) sparing as well as IMRT QA passing rate which is investigated. Methods: Two sites (prostate and head and neck) that have maximum utilization of VMAT were investigated. Two previously treated VMAT patients were chosen. For each patient 10 plans were created by maintaining constant optimization constraints while varying collimator angles from 0-90 deg at an interval of 10 degrees for the first arc and the appropriate complimentary angle for the second arc. Plans were created with AAA algorithm using 6 MV beam on a Varian IX machine with Millennium 120 MLC. The dose-volume histogram (DVH) for each plan was exported and dosimetric parameters (D98, D95, D50, D2) as well homogeneity index (HI) and conformity index (CI) were computed. Each plan was validated for QA using ArcCheck with gamma index passing criteria of 2%/2 mm and 3%/3 mm. Additionally, normal tissue complication probability (NTCP) for each OAR was computed using Uzan-Nahum software. Results: The CI values for both sites had no impact as target volume coverage in every collimator angle were the same since it was optimized for adequate coverage. The HI which is representative of DVH gradient or dose uniformity in PTV showed a clear trend in both sites. The NTCP for OAR (brain and cochlea) in H&N plan and (bladder and rectum) in prostate plan showed a distinct superiority for collimator angles between 15-30 deg. The gamma passing rates were not correlated with angle. Conclusion: Based on CI, HI, NTCP and gamma passing index, it can be concluded that collimator angles should be maintained within 15–30 deg.

60 APPLIED LIFE SCIENCES↗

Cryogenic safety aspect of the low -$\beta$ magnest systems at the Large Hadron Collider (LHC)

The low-{beta} magnet systems are located in the LHC insertion regions around the four interaction points. They are the key elements in the beams focusing/defocusing process and will allow proton collisions at a luminosity of up to 10{sup 34}cm{sup -2}s{sup -1}. Large radiation dose deposited at the proximity of the beam collisions dictate stringent requirements for the design and operation of the systems. The hardware commissioning phase of the LHC was completed in the winter of 2010 and permitted to validate this system safe operation. This paper presents the analysis used to qualify and quantify the safe operation of the low-{beta} magnet systems in the Large Hadron Collider (LHC) for the first years of operation.

43 PARTICLE ACCELERATORS↗

Final Review of Safety Assessment Issues at Savannah River Site, August 2011

At the request of Savannah River Nuclear Solutions (SRNS) management, a review team composed of experts in atmospheric transport modeling for environmental radiation dose assessment convened at the Savannah River Site (SRS) on August 29-30, 2011. Though the meeting was prompted initially by suspected issues related to the treatment of surface roughness inherent in the SRS meteorological dataset and its treatment in the MELCOR Accident Consequence Code System Version 2 (MACCS2), various topical areas were discussed that are relevant to performing safety assessments at SRS; this final report addresses these topical areas.

54 ENVIRONMENTAL SCIENCES↗

Oxidative and Radiative Pretreatment of Lignocellulose Feedstock for Producing Biofuel

The oxidizabilities of the principal lignocellulose feedstock constituents (cellulose, lignin, xylan) and feedstock exposed to gamma-radiation are investigated. The oxidizability of wheat straw by hydrogen peroxide increases if the absorbed gamma-radiation dose is increased to 200-300 kGy and the feedstock particle size is reduced to 0.8-1.2 mm. Hemicelluloses are practically completely degraded by catalytic peroxide treatment (mass loss of ~95%) whereas lignin is destroyed much less (mass loss of ~27%) under the same conditions. Pretreatment of the feedstock increases the cellulose content in the lignocellulose feedstock and can be used to produce biofuels (EtOH or 2,5-dimethylfuran).

60 APPLIED LIFE SCIENCES↗

SU-E-QI-15: Single Point Dosimetry by Means of Cerenkov Radiation Energy Transfer (CRET)

Purpose: Cerenkov light is generated when a charged particles with energy greater then 250 keV, moves faster than the speed of light in a given medium. Both x-ray photons and electrons produce optical Cerenkov photons during the static megavoltage linear accelerator (LINAC) operational mode. Recently, Cerenkov radiation gained considerable interest as possible candidate as a new imaging modality. Optical signals generated by Cerenkov radiation may act as a surrogate for the absorbed superficial radiation dose. We demonstrated a novel single point dosimetry method for megavoltage photon and electron therapy utilizing down conversion of Cerenkov photons. Methods: The custom build signal characterization system was used: a sample holder (probe) with adjacent light tight compartments was connected via fiber-optic cables to a photon counting photomultiplier tube (PMT). One compartment contains a medium only while the other contains medium and red-shifting nano-particles (Q-dots, nanoclusters). By taking the difference between the two signals (Cerenkov photons and CRET photons) we obtain a measure of the down-converted light, which we expect to be proportional to dose as measured with an adjacent ion chamber. Experimental results are compared to Monte Carlo simulations performed using the GEANT4 code. Results: The signal correlation between CR signal, CRET readings and dose produced by LINAC at a single point were investigated. The experimental results were compared with simulations. The dose linearity, signal to noise ratio and dose rate dependence were tested with custom build CRET based probe. Conclusion: Performance characteristics of the proposed single point CRET based probe were evaluated. The direct use of the induced Cerenkov emission and CRET in an irradiated single point volume as an indirect surrogate for the imparted dose was investigated. We conclude that CRET is a promising optical based dosimetry method that offers advantages over those already proposed.

60 APPLIED LIFE SCIENCES↗

Outcome Prediction After Surgery and Chemoradiation of Squamous Cell Carcinoma in the Oral Cavity, Oropharynx, and Hypopharynx: Use of Baseline Perfusion CT Microcirculatory Parameters vs. Tumor Volume

Purpose: To assess whether pretreatment perfusion computed tomography (PCT) may predict outcome in chemoradiated patients with oral cavity, oropharynx, and hypopharynx squamous cell carcinoma (SCCA) after surgical excision. Materials and Methods: Twenty-one patients with SCCA were examined before treatment. The primary site was oral cavity in 6, oropharynx in 7, and hypopharynx in 8 patients; there were 11 T2, 6 T3, and 4 T4 tumors. PCT was performed at the level of largest tumor diameter based on standard neck CT. The data were processed to obtain blood flow (BF), blood volume (BV), mean transit time (MTT), and permeability surface area product (PS). Regions of interest were free-hand positioned on the lesions to obtain PCT measurements. Tumor volume was also calculated. Follow-up was performed with positron emission tomography (PET)/CT and endoscopy. Pearson correlation coefficient was used for comparison between the subgroups. A regression model was constructed to predict recurrence based on the following predictors: age, gender, tumor (T) and nodal (N) stage, tumor volume, and PCT parameters. Results: BF{sub mean}, BF{sub max}, BV{sub mean}, BV{sub max}, MTT{sub mean}, PS{sub mean}, and PS{sub max} were significantly different between patients with and without tumor recurrence (0.0001, p < 0.04). T stage, tumor volume, N stage, BF{sub max}, BV{sub max}, MTT{sub mean}, and radiation dose (p < 0.001) were independent predictors for recurrence. Cox proportional hazards model for tumor recurrence revealed significantly increased risk with high tumor volume (p = 0.00001, relative risk [RR] 7.4), low PS{sub mean} (p = 0.0001, RR 14.3), and low BF{sub max} (p = 0.002, RR 5.9). Conclusions: Our data suggest that PCT parameters have a prognostic role in patients with SCCA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Frameless Image-Guided Intracranial Stereotactic Radiosurgery: Clinical Outcomes for Brain Metastases

Purpose: After preclinical investigations confirming the accuracy of target localization by frameless image-guided radiosurgery, we report the clinical outcomes of patients with brain metastases who underwent frameless radiosurgery. Methods and Materials: Between 2005 and 2006, 53 patients underwent frameless stereotactic radiosurgery using a linear accelerator equipped with on-board image guidance for the treatment of 158 brain metastases. The radiation doses were delivered in a single fraction (dose range, 12-22 Gy; median, 18). Patients were followed with magnetic resonance imaging scans at 2-3-month intervals. Progression-free survival was the primary study endpoint. Results: With a median follow-up of 38 weeks (range, 14-112), the overall survival rate was 70% at 6 months, 44% at 1 year, 29% at 18 months, and 16% at 24 months. Local control was achieved in 90% of 168 treated lesions at 6 months, 80% at 12 months, 78% at 18 months, and 78% at 24 months. Local control tended to be improved in lesions treated with {>=}18 Gy and for lesions <0.2 cm{sup 3}. Adverse events occurred in 5 patients (9.6%). No evidence of imaging changes on post-stereotactic radiosurgery scans was found to suggest mistargeting of a radiation isocenter. Conclusion: The clinical outcomes after frameless stereotactic radiosurgery were comparable to those after frame-based radiosurgery techniques. Given its significant advantages in terms of patient comfort, ability to use fractionated treatment regimens, and convenience in scheduling of personnel and equipment resources, frameless radiosurgery will likely become a common technique for intracranial radiosurgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Technical Note: Improving the VMERGE treatment planning algorithm for rotational radiotherapy

Purpose: The authors revisit the VMERGE treatment planning algorithm by Craft et al. [“Multicriteria VMAT optimization,” Med. Phys. 39, 686–696 (2012)] for arc therapy planning and propose two changes to the method that are aimed at improving the achieved trade-off between treatment time and plan quality at little additional planning time cost, while retaining other desirable properties of the original algorithm. Methods: The original VMERGE algorithm first computes an “ideal,” high quality but also highly time consuming treatment plan that irradiates the patient from all possible angles in a fine angular grid with a highly modulated beam and then makes this plan deliverable within practical treatment time by an iterative fluence map merging and sequencing algorithm. We propose two changes to this method. First, we regularize the ideal plan obtained in the first step by adding an explicit constraint on treatment time. Second, we propose a different merging criterion that comprises of identifying and merging adjacent maps whose merging results in the least degradation of radiation dose. Results: The effect of both suggested modifications is evaluated individually and jointly on clinical prostate and paraspinal cases. Details of the two cases are reported. Conclusions: In the authors’ computational study they found that both proposed modifications, especially the regularization, yield noticeably improved treatment plans for the same treatment times than what can be obtained using the original VMERGE method. The resulting plans match the quality of 20-beam step-and-shoot IMRT plans with a delivery time of approximately 2 min.

60 APPLIED LIFE SCIENCES↗

Neurochemical Evidence of Potential Neurotoxicity After Prophylactic Cranial Irradiation

Purpose: To examine whether cerebrospinal fluid biomarkers for neuroaxonal damage, neuroglial activation, and amyloid β–related processes could characterize the neurochemical response to cranial radiation. Methods and Materials: Before prophylactic cranial irradiation (PCI) of patients with small cell lung cancer, each patient underwent magnetic resonance imaging of the brain, lumbar puncture, and Mini-Mental State Examination of cognitive function. These examinations were repeated at approximately 3 and 12 months after radiation. Results: The major findings were as follows. (1) Cerebrospinal fluid markers for neuronal and neuroglial injury were elevated during the subacute phase after PCI. Neurofilament and T-tau increased 120% and 50%, respectively, after PCI (P<.05). The same was seen for the neuroglial markers YKL-40 and glial fibrillary acidic protein, which increased 144% and 106%, respectively, after PCI (P<.05). (2) The levels of secreted amyloid precursor protein-α and -β were reduced 44% and 46%, respectively, 3 months after PCI, and the levels continued to decrease as long as 1 year after treatment (P<.05). (3) Mini-Mental State Examination did not reveal any cognitive decline, indicating that a more sensitive test should be used in future studies. Conclusion: In conclusion, we were able to detect radiation therapy–induced changes in several markers reflecting neuronal injury, inflammatory/astroglial activation, and altered amyloid precursor protein/amyloid β metabolism, despite the low number of patients and quite moderate radiation doses (20-30 Gy). These changes are hypothesis generating and could potentially be used to assess the individual risk of developing long-term symptoms of chronic encephalopathy after PCI. This has to be evaluated in large studies with extended clinical follow-up and more detailed neurocognitive assessments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Micro-Optical Ring Electrode: A Sensor for Multiple Actinide Ions Monitoring - 17586

We present on the development of the Micro-Optical Ring Electrode (MORE) for the analysis of trans-uranium elements in aqueous mixtures. The MORE is a photo-electrochemical device based on a ring microelectrode that uses the insulator interior to the ring as a light guide. This single device exploits the unique photophysical and electrochemical properties of multiple analytes present in mixtures to quantify them. Our study aims to develop a protocol for the analysis of ions of uranium, neptunium and plutonium, which are most relevant to the nuclear industry, especially in the areas of decommissioning and fuel reprocessing, where speedy and safe identification of radioactive contaminants is essential. The technique offers a number of advantages over traditional methods in the area of radiochemical analysis such as real time monitoring in-situ, reduced radiation dose impact to the analyst as a result of greatly reduced sample handling and preparation, improved analysis times allowing quick decision making, at a much reduced cost (e.g. compared to ICP-MS and Scintillation counting). Here we present results of our study on non-radioactive surrogates for the target elements and discuss the advantages the technique can deliver to the nuclear industry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Patient-based radiographic exposure factor selection: a systematic review

Digital technology has wider exposure latitude and post-processing algorithms which can mask the evidence of underexposure and overexposure. Underexposure produces noisy, grainy images which can impede diagnosis and overexposure results in a greater radiation dose to the patient. These exposure errors can result from inaccurate adjustment of exposure factors in response to changes in patient thickness. This study aims to identify all published radiographic exposure adaptation systems which have been, or are being, used in general radiography and discuss their applicability to digital systems. Studies in EMBASE, MEDLINE, CINAHL and SCOPUS were systematically reviewed. Some of the search terms used were exposure adaptation, exposure selection, exposure technique, 25% rule, 15% rule, DuPont™ Bit System and radiography. A manual journal-specific search was also conducted in The Radiographer and Radiologic Technology. Studies were included if they demonstrated a system of altering exposure factors to compensate for variations in patients for general radiography. Studies were excluded if they focused on finding optimal exposures for an ‘average’ patient or focused on the relationship between exposure factors and dose. The database search uncovered 11 articles and the journal-specific search uncovered 13 articles discussing systems of exposure adaptation. They can be categorised as simple one-step guidelines, comprehensive charts and computer programs. Only two papers assessed the efficacy of exposure adjustment systems. No literature compares the efficacy of exposure adaptations system for film/screen radiography with digital radiography technology nor is there literature on a digital specific exposure adaptation system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Arterial Phase CTA Replacement by a Virtual Arterial Phase Reconstruction from a Venous Phase CTA: Preliminary Results Using Detector-Based Spectral CT

Objective: To assess the feasibility of creating virtual monoenergetic arterial images from venous phase CTA obtained on a detector-based spectral CT scanner and quantitatively compare the signal-to-noise (SNR) and contrast-to-noise (CNR) ratios of the major arteries to those on polyenergetic true arterial phase images. Methods: In this retrospective study, 23 patients (15 men and 8 women, median age 68 years) who underwent triple-phase CTA on a spectral CT scanner for aortic endograft surveillance were included. The venous phase CTA of each study was reconstructed to generate virtual monoenergetic images at various keV, which were compared to true arterial phase CTA images. SNR and CNR of the aortoiliac arteries were evaluated by testing the differences in means and non-inferiority of virtual arterial images to true arterial images. Effective radiation dose was calculated for standard triple-phase studies in comparison with dual-phase and single-phase spectral CT examinations. Results: Virtual monoenergetic images demonstrated non-inferior (P < 0.05) arterial SNR and CNR compared to true arterial images at 40 keV for all arteries, at 45–50 keV for the thoracic and suprarenal aorta, and at 45–55 keV for the infrarenal aorta and iliac arteries. Significantly higher (P < 0.05) arterial attenuation was obtained at 40 keV for the aortoiliac arteries. Mean effective dose for conventional triple-phase studies was 32.5 mSv in comparison with 21.3 mSv for dual-phase non-contrast/venous scans and 11.3 mSv for single-phase venous scans. Conclusions: Detector-based spectral CT enables creation of virtual monoenergetic arterial images from venous phase CTA with equivalent and in some cases significantly higher SNR/CNR of major arteries compared to images from true arterial phase polyenergetic CTA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging the Breast in Pregnant or Lactating Women

Purpose of Review: To describe the imaging evaluation of common benign and malignant breast lesions encountered in pregnant or lactating women. Recent Findings: There is increasing prevalence of pregnancy-associated breast cancer as the age of women during pregnancy increases. Women in the first 10 years following pregnancy demonstrate an elevated risk for breast cancer compared to the average population. MRI has been shown to be more sensitive for evaluating the extent of disease in lactating patients than mammography or ultrasound. Summary: The hormonal effects of pregnancy and lactation on the breast lead to distinct physiologic changes and pathologic lesions, which can manifest in unique imaging appearances. Most patients will undergo ultrasound for primary diagnostic evaluation. While mammography is not routinely utilized, it is not contraindicated even in pregnancy given the negligible radiation dose to the fetus. While most detected lesions are benign, pregnancy-associated breast cancer (PABC) is a rare diagnosis that must always be excluded. Women with PABC have a worse prognosis than age-matched controls partly due to delay in diagnosis. Thus prompt and accurate work-up of PABC is critical to improve outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-A-BRF-09: Integration of High-Resolution MRSI Into Glioblastoma Treatment Planning

Purpose: Identification of a metabolite signature that shows significant tumor cell infiltration into normal brain in regions that do not appear abnormal on standard MRI scans would be extremely useful for radiation oncologists to choose optimal regions of brain to treat, and to quantify response beyond the MacDonald criteria. We report on integration of high-resolution magnetic resonance spectroscopic imaging (HR-MRSI) with radiation dose escalation treatment planning to define and target regions at high risk for recurrence. Methods: We propose to supplement standard MRI with a special technique performed on an MRI scanner to measure the metabolite levels within defined volumes. Metabolite imaging was acquired using an advanced MRSI technique combining 3D echo-planar spectroscopic imaging (EPSI) with parallel acquisition (GRAPPA) using a multichannel head coil that allows acquisition of whole brain metabolite maps with 108 μl resolution in 12 minutes implemented on a 3T MR scanner. Elevation in the ratio of two metabolites, choline (Cho, elevated in proliferating high-grade gliomas) and N-acetyl aspartate (NAA, a normal neuronal metabolite), was used to image infiltrating high-grade glioma cells in vivo. Results: The metabolite images were co-registered with standard contrast-enhanced T1-weighted MR images using in-house registration software and imported into the treatment-planning system. Regions with tumor infiltration are identified on the metabolic images and used to create adaptive IMRT plans that deliver a standard dose of 60 Gy to the standard target volume and an escalated dose of 75 Gy (or higher) to the most suspicious regions, identified as areas with elevated Cho/NAA ratio. Conclusion: We have implemented a state-of-the-art HR-MRSI technology that can generate metabolite maps of the entire brain in a clinically acceptable scan time, coupled with introduction of an imaging co-registration/ analysis program that combines MRSI data with standard imaging studies in a clinically useful fashion.

60 APPLIED LIFE SCIENCES↗

Intensity-Modulated Radiotherapy is Associated With Improved Global Quality of Life Among Long-term Survivors of Head-and-Neck Cancer

Purpose: To compare the long-term quality of life among patients treated with and without intensity-modulated radiotherapy (IMRT) for head-and-neck cancer. Methods and Materials: University of Washington Quality of Life instrument scores were reviewed for 155 patients previously treated with radiation therapy for locally advanced head-and-neck cancer. All patients were disease free and had at least 2 years of follow-up. Eighty-four patients (54%) were treated with IMRT. The remaining 71 patients (46%) were treated with three-dimensional conformal radiotherapy (3D CRT) by use of initial opposed lateral fields matched to a low anterior neck field. Results: The mean global quality of life scores were 67.5 and 80.1 for the IMRT patients at 1 and 2 years, respectively, compared with 55.4 and 57.0 for the 3D CRT patients, respectively (p < 0.001). At 1 year after the completion of radiation therapy, the proportion of patients who rated their global quality of life as 'very good' or 'outstanding' was 51% and 41% among patients treated by IMRT and 3DCRT, respectively (p = 0.11). At 2 years, the corresponding percentages increased to 73% and 49%, respectively (p < 0.001). On multivariate analysis accounting for sex, age, radiation intent (definitive vs. postoperative), radiation dose, T stage, primary site, use of concurrent chemotherapy, and neck dissection, the use of IMRT was the only variable independently associated with improved quality of life (p = 0.01). Conclusion: The early quality of life improvements associated with IMRT not only are maintained but apparently become more magnified over time. These data provide powerful evidence attesting to the long-term benefits of IMRT for head-and-neck cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Examining the Effect of Plume Rise on Radiological Consequences of Nuclear Accidents

A nuclear accident could cause release of radioactive material outside containment. This material will eventually disperse into the surrounding environment, and could pose a serious threat to public safety, and environment. Mitigation of radiological consequences of such an accident is highly desirable, and since Fukushima accident, there has been a growing focus on nuclear utilities to develop capabilities for this purpose. Undoubtedly, suppression of radioactive material release and dispersion is the primary mean for mitigating radiological consequences nevertheless alternative methods should also be explored to broaden the spectrum of choices for actual circumstances. As we know that, dispersion of radioactive material and subsequent radiological consequences are affected by plume rise. Plume rise is an important factor in determining ground level contamination since it can increase effective release height appreciably provided that effluent discharge speed and temperature is high enough. Under most circumstances, one can expect reduction in radiological consequences due to lower levels of radiation dose and ground contamination in the presence of adequate plume rise. Nevertheless, the effect of plume rise is usually ignored in radiological consequence studies for the sake of conservatism, and lack of information. However, this particular attribute of plume rise interested us to investigate the effect of plume rise in the scope of consequence mitigation and how this advantage could be utilized during an accident progression to minimize the impact of radioactivity release to the environment. In this work, we examine the effect of plume rise on radiological consequences of a nuclear accident for plume rise contributions much larger ({approx}500 m) than usually achievable in normal circumstances. The effect of plume rise on radiological consequences is quantified in this study as decontamination credit (DCC) achievable corresponding to maximum annual dose. This analysis is performed for a number of release heights and atmospheric conditions. We discuss available results in the scope of radiological consequence mitigation, devising a strategy for utilizing plume rise phenomenon with the help of an external propelling device like a jet engine for radiological consequence management. This study is continuation of our efforts for devising systems and strategies to mitigate consequences of radioactivity release accidents like Fukushima. We have proposed several ideas for suppressing/preventing the dispersion of released radioactive material to the environment using offsite equipment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗