Search NASA⌕ Search

SEARCH · Search NASA

Results for “RELIABLE OPERATION PERFORMANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Experimental Investigation of a Novel High Energy Density Mobile Sorption–based Thermal Battery

Around 20% of the total primary energy use in the United States is for thermal demands of buildings, such as space cooling, dehumidification, and space heating. Low-grade geothermal energy is abundant and could effectively satisfy these thermal demands. However, low-grade geothermal energy is underused because geothermal fluids have an energy density too low to justify transportation between the existing resources and buildings. The mobile sorption-based thermal battery (MSTB) system was thus developed to store the low-temperature heat using three-phase (vapor-liquid solution-solid crystal) sorption technology with a much higher energy density than a geothermal fluid provides. The energy density of an MSTB is over 6 times that of conventional hot water, enabling economical long-distance transport of low-temperature heat for thermal end uses. This can alleviate peak demand on the electricity grid by offsetting space-conditioning loads, improving the reliability and resilience of US energy systems. High energy density, fast crystallization, and crystal dissolution of the sorption material are critical to the viability and performance of the MSTB system. Therefore, the design and operation of MSTB systems must ensure effective generation and dissolution of the salt crystals inside the MSTB. To achieve this target, this study developed a prototype MSTB and its testing apparatus, and experimentally investigated the prototype MSTB. The crystallization and dissolution performance were also theoretically defined and quantified. The experimental results showed that the prototype MSTB was able to achieve an energy storage density of 903.0 kJ/kg and a maximum discharge rate of 1.3 kW. This study proves the feasibility and high performance of the MSTB concept, which is helpful to further study and development of the MSTB system.

Wang, Lingshi↗

Revenue Opportunities through Ancillary Services for Nuclear Power Plants with Integrated Firebrick Resistance- Heated Energy Storage (FIRES)

Deregulation of electricity markets has brought about major changes in the ways investments in and operation of power plants are planned and optimized. Although many NPPs have seen reduced revenue in recent years as power purchase agreement end and wholesale market electricity prices have remained low, there are opportunities to expand the technical capabilities of NPPs, participate in additional market services and increase revenue. This transaction summarizes the opportunities provided by participation in ancillary services markets potentially made possible by integration of thermal energy storage capacity, specifically the Firebrick Resistance-heated Energy Storage System (FIRES), into future nuclear power plants with high-temperature reactors and Nuclear Air-Brayton combined cycle (NACC) power conversion. The restructuring, or deregulation, of electric power systems in most of Europe and North America has had a substantial impact on the economic performance of currently operating nuclear power plants (NPPs) and the prospects for new builds. Owners of NPPs in some markets have expressed concern that low wholesale electricity market prices and insufficient compensation for capacity, reliability, and other services are threatening the financial viability of their plants. However, both current and future NPPs have the potential to increase their competitiveness by increasing the flexibility of their electricity output. Flexible output has previously only been possible in water-cooled reactors through load-following operation, which requires core power maneuvers and operation of the steam turbine at reduced efficiency. Integration of thermal energy storage systems (TESS) provides an alternative, providing the plant the option to either output electricity or store heat for greater later electric output. The plant owner may thus increase sales of electricity during hours when it is most valuable. Even more, some TESS technologies have the potential to greatly increase the net ramp rate capability of the plant. The ability to rapidly change net power output to the grid may make it possible for NPPs to secure additional revenue by providing additional minute-by-minute balancing services to the grid. FIRES is only one technology out of many that might provide additional technical capabilities at NPPs, and this discussion has only highlighted the opportunities in a single market. Analysis of other options, include steam accumulator systems, nitrate salt TESS, phase change material TESS, and opportunities in other markets are subjects of ongoing work. Deregulation of electricity markets has brought about major changes in the ways investments in and operation of power plants are planned and optimized. Although many NPPs have seen reduced revenue in recent years as power purchase agreements end and wholesale market electricity prices have remained low, there are opportunities to expand the technical capabilities of NPPs, participate in additional market services, and increase revenue. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FORCE Regression Testing

Via programs including the Light Water Reactor Sustainability and Integrated Energy Systems, the U.S. Department of Energy has invested in the Framework for Optimization of ResourCes and Economics (FORCE) software framework (Idaho National Laboratory 2024a) for the technical and economic analysis of nuclear-integrated energy systems (IES). Nuclear IES expand the use of nuclear from traditional baseload electricity generation to a flexible and adaptive source of combined heat and power. Nuclear heat can be used in the production of a variety of energy currencies such as hydrogen and ammonia as well as other heat applications including water desalination and district heating. FORCE is designed with the intent to provide interconnected analysis tools that enable the accurate technical and economic assessment of specific nuclear IES configurations for individual energy markets. FORCE consists of three main analysis pathways: HYBRID (Idaho National Laboratory 2024b), which contains high-resolution physical models for IES; Holistic Energy Resource Optimization Network (HERON) (Idaho National Laboratory 2024c), which analyzes IES long-term economic viability; and Optimization of Real-time Capacity Allocation (ORCA) (Idaho National Laboratory 2024d), designed for real-time control of IES via digital twins and optimal decision making, including autonomous and remote operation research. Development of the FORCE ecosystem is guided by three pillars: capability, which assures that the computational requirements of IES analysis are met by the software tools; reliability, which provides for consistent code performance and expected behaviors; and accessibility, which lowers the barrier to entry for using the software and accelerates analysis by users beyond the FORCE primary developers. Reliability of the FORCE ecosystem is established according to the American Nuclear Society?s Nuclear Quality Assurance (NQA-1) program [American Society of Mechanical Engineers 1982], with specific levels of software quality assurance (SQA) within NQA-1 applied to each software tool in FORCE. As the tools within FORCE have matured, some integration algorithms to accurately connect the software tools for holistic analysis have been developed and deployed within the FORCE software repository. In accordance with NQA-1 standards, regression tests are required to guarantee the software performs consistently even when new capabilities are added to the software. In this report, we document the deployment of both unit tests, which test the consistent behavior of small pieces of the FORCE code base, as well as integration tests, which test the consistent performance of full use cases for the FORCE integration algorithms. We further document the encapsulation of these tests within a test harness, which collectively checks for each successful test completion on demand. Finally, we document the automation of the test harness using GitHub Actions [GitHub 2024], which require all tests succeed before any new capability or other changes can be added to the FORCE integration software

97 MATHEMATICS AND COMPUTING↗

Impact of Hydrological Data on Power System Operational Studies: Preprint

Hydropower is expected to play an important role in maintaining grid reliability and flexibility as the share of of variable renewable energy increases. While the current hydropower operational models have been studied and used widely, they haven't been updated for decades to meet new performance standards. For example, current steady state and dynamic models often neglect hydrological conditions, which may lead to unrealistic expectations when relying on hydropower for energy and ancillary services. To study this impact, a multi-timescale hydrological model was created by leveraging the National Renewable Energy Laboratory-developed Multi-timescale Integrated Dynamics and Scheduling (MIDAS) tool. Using MIDAS, we compare the impact of considering hydrological conditions in a day-ahead unit commitment (DAUC) schedule on the reduced 240-bus Western Interconnect (WI) test system under winter and summer case studies. We show that neglecting current hydrological conditions of hydropower plants in power system models can lead to an overestimation of hydropower capabilities, which could lead to power balancing issues. For example, power system DAUC simulation results of our reduced test system show that in the case where hydrological conditions are not considered in the model, an approximate 31% overestimation of hydropower capabilities occurs in the summer case and approximately 60% occurs in the winter case compared to what is available. Additionally, results show an underestimation of WI day-ahead power system generation costs by approximately $54M - $80M in the weekly summer scenario and $116M - $126M in the weekly winter scenario. This analysis helps to underscore the importance of considering hydrological data in power system operational studies.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

A high performance microcomputer for space applications

This paper presents a description of a high-performance single board LSI microprocessor (the ATAC-16MS), which forms the core of the attitude and articulation control system of the Galileo spacecraft. The requirements of high speed, low power (20 watts), high reliability and radiation immunity are discussed in terms of the resulting implementation and trade-offs. The problems involved in the transition of a currently operational, fully-militarized processor into a space-qualified processor are summarized. System considerations for the effective use of the ATAC-16MS are also discussed, including the dual block-redundant architecture, the selective application of power for fault isolation and the trade-offs between low power dissipation and high performance of the peripheral circuitry for space applications.

Jack, L.↗

Development of a Thin Film Primary Surface Heat Exchanger for Advanced Power Cycles

This project objective is to develop a high-temperature design upgrade for an existing primary surface heat exchanger so that the redesigned hardware is capable of operation in CO 2 at temperatures up to 1,510°F (821°C) and pressure differentials up to 130 psi (9 bar). The heat exchanger is proposed for use as a recuperator in an advanced low-pressure oxy-fuel Brayton cycle that is predicted to achieve over 50% thermodynamic efficiency, although the heat exchanger could also be used in other high-temperature, low-differential pressure cycles. This report describes the progress to date, which includes continuing work performed to select and test new candidate materials for the recuperator redesign, final mechanical and thermal performance analysis results of various redesign concepts, and the preliminary design of a test loop for the redesigned recuperator including a budgetary estimate for detailed test loop design, procurement, and test operation. A materials search was performed in order to investigate high-temperature properties of many candidate materials, including high-temperature strength and nickel content. These properties were used to rank the candidate materials, resulting in a reduced list of nine materials for corrosion testing. Multiple test rigs were considered and analyzed for short-term corrosion testing and Thermal Gravimetric Analysis (TGA) was selected as the most cost-effective option for evaluating corrosion resistance of the candidate materials. In addition, tantalum, niobium, and chromium coatings were identified as potential options for increased corrosion resistance. The test results show that many materials exhibit relatively low weight gain rates, and that niobium and tantalum coatings may improve corrosion resistance for many materials, while chromium coatings appear to oxidize and debond quickly. Metallurgical analysis of alloys was also performed, showing evidence of intergranular attack in 282 that may cause long-term reliability problems in CO 2 service at these temperatures. However, long-term testing in a flowing environment is recommended in order to understand accurately the severity of the attack. Detailed economic modeling of the existing air cycle recuperator and CO 2 cycle recuperator options was also completed, including costs for material, fabrication, fuel, maintenance, and operation. The analysis results show that the increased capital cost for high-temperature materials may be offset by higher cycle efficiencies, decreasing the overall lifetime cost of the system. The economic analysis also examines costs associated with increased pressure drop and material changes for two redesign options. These results show that, even with slightly reduced performance and/or higher material costs, the lifetime cost per energy production may still be reduced by over 12%. The existing recuperator design information was provided by Solar Turbines, Inc. via several models, drawings, and design handoff meetings. Multiple fluid/thermal and structural models were created in order to analyze critical recuperator performance and mechanical strength in critical areas throughout the redesign process. These models were analyzed for a baseline condition (consistent with current Mercury 50 operation) for validation purposes. Results are presented for heat transfer coefficients and pressure drops, matching well with the existing operational data. Simulation of higher-temperature CO 2 conditions was also performed, showing a slight expected increase in both heat transfer and pressure drop. Mechanical analysis results for critical areas on the cross-flow and counter-flow sheets have also been obtained for air and CO 2 cases. These results show similar stresses in both cases but significantly reduced safety factors for the CO 2 case due to reduced yield and creep rupture strengths of alloy 625 at the higher temperatures. A concept brainstorm session and initial down-selection were completed in order to identify promising redesign options for further analysis. Detailed analysis of all promising redesign options was performed via finite element and computational fluid dynamic simulations in order to characterize mechanical and thermal-fluid performance of each option. These options included material change, various sheet thickness configurations, pitch and phasing of cross-flow and counter-flow sheets, and separator sheets. The analysis results have identified two viable redesign options that maintain existing safety margins optimally through a material change to Haynes 282 and (A) sheet thickness increases of 40% on the counter-flow sheet and 75% on the hot side cross-flow corrugation sheet or (B) addition of a separator sheet in the counter-flow section while maintaining the original counter-flow sheet thickness and increasing the cross-flow corrugation sheet thickness by 90% to account for the increase in cell height. While both options satisfy mechanical stress constraints, the separator sheet design has a higher part count, slightly reduced heat transfer, and slightly higher pressure drop than the first option and is not preferred. Finally, several test loop concepts have been developed for different full-scale and reduced-scale recuperator testing options. For each option, various loop components, such as heat exchangers, valves, heaters, and compressors, were evaluated in an effort to maximize utilization of existing resources. All concepts utilize an existing 3-MW CO 2 compressor, heater, and loop coolers, but the concepts vary by incorporating different amounts of new equipment for achieving various flow rates (all concepts operate at design pressure and temperature). The third concept achieves a 1 kg/s test without purchasing any costly equipment (coolers, heaters, blowers, etc.). Since the stacked cell design of the recuperator results in the same flow conditions at each core cell (even for a reduced-scale test). Thus, test loop Concept #3 was selected for the preliminary design. This loop design is detailed within the report, culminating in a budgetary estimate of $1,013,000.00 for the detailed design, construction, commissioning, and operation of a high-temperature recuperator test loop.

03 NATURAL GAS↗

An Efficient Approach for the Reliability Analysis of Phased-Mission Systems with Dependent Failures

We consider the reliability analysis of phased-mission systems with common-cause failures in this paper. Phased-mission systems (PMS) are systems supporting missions characterized by multiple, consecutive, and nonoverlapping phases of operation. System components may be subject to different stresses as well as different reliability requirements throughout the course of the mission. As a result, component behavior and relationships may need to be modeled differently from phase to phase when performing a system-level reliability analysis. This consideration poses unique challenges to existing analysis methods. The challenges increase when common-cause failures (CCF) are incorporated in the model. CCF are multiple dependent component failures within a system that are a direct result of a shared root cause, such as sabotage, flood, earthquake, power outage, or human errors. It has been shown by many reliability studies that CCF tend to increase a system's joint failure probabilities and thus contribute significantly to the overall unreliability of systems subject to CCF.We propose a separable phase-modular approach to the reliability analysis of phased-mission systems with dependent common-cause failures as one way to meet the above challenges in an efficient and elegant manner. Our methodology is twofold: first, we separate the effects of CCF from the PMS analysis using the total probability theorem and the common-cause event space developed based on the elementary common-causes; next, we apply an efficient phase-modular approach to analyze the reliability of the PMS. The phase-modular approach employs both combinatorial binary decision diagram and Markov-chain solution methods as appropriate. We provide an example of a reliability analysis of a PMS with both static and dynamic phases as well as CCF as an illustration of our proposed approach. The example is based on information extracted from a Mars orbiter project. The reliability model for this orbiter considers the various phases of Launch, Cruise, Mars Orbit Insertion, and Orbit. Some of the CCF for the orbiter in this mission include environmental effects, such as micrometeoroids, human operator errors, and software errors.

reliability analysis↗

A Report on Simulation-Driven Reliability and Failure Analysis of Large-Scale Storage Systems

High-performance computing (HPC) storage systems provide data availability and reliability using various hardware and software fault tolerance techniques. Usually, reliability and availability are calculated at the subsystem or component level using limited metrics such as, mean time to failure (MTTF) or mean time to data loss (MTTDL). This often means settling on simple and disconnected failure models (such as exponential failure rate) to achieve tractable and close-formed solutions. However, such models have been shown to be insufficient in assessing end-to-end storage system reliability and availability. We propose a generic simulation framework aimed at analyzing the reliability and availability of storage systems at scale, and investigating what-if scenarios. The framework is designed for an end-to-end storage system, accommodating the various components and subsystems, their interconnections, failure patterns and propagation, and performs dependency analysis to capture a wide-range of failure cases. We evaluate the framework against a large-scale storage system that is in production and analyze its failure projections toward and beyond the end of lifecycle. We also examine the potential operational impact by studying how different types of components affect the overall system reliability and availability, and present the preliminary results

97 MATHEMATICS AND COMPUTING↗

Modeling Framework to Analyze Performance and Structural Reliability of Solid Oxide Electrolysis Cells

Solid oxide electrolysis cells (SOEC) have been receiving significant attention recently because of their high energy efficiency and fast hydrogen production. In this study a multi-physics model to simulate the SOEC performance and structural reliability of a state-of-the-art planar SOEC design was developed. The electrochemical reactions, fluid dynamics, species transport, electron transfer, and heat transfer were modeled in the commercial computational fluid dynamics (CFD) software STAR-CCM+. The thermomechanical analysis and the associated structural reliability evaluations were conducted using the commercial finite element analysis software ANSYS. The electrochemistry model was validated by using the experimentally obtained current-voltage (I-V) characteristics of the electrode-supported SOECs. The reliability analysis using a risk-of-rupture approach showed low failure probabilities under standard operating conditions considered in this study. For cells operated at voltages well above a thermoneutral voltage, the reliability evaluations indicated a potential risk of cell failure, but the damage was concentrated locally in specific areas of the cell which typically do not lead to total loss of cell function. The presented approach provides insights for evaluating representative cell and stack performances and structural reliability without intensive testing and for developing optimally performing and structurally reliable SOECs for efficient hydrogen generation.

25 ENERGY STORAGE↗

Measuring Unique Contextual Factors: Group Living Skills

BACKGROUND The Human Factors and Behavioral Performance Exploration Measures (HFBP-EM) suite is a set of standardized measures used to assess behavioral health and performance risks related to future exploration-class space missions. During the HFBP-EM suite development, the importance of assessing unique contextual factors to understand the drivers of team dynamics was identified. Group living skills are a unique workplace skill which applies to those coworkers who live and work together. As mission lengths become longer, the line between work and non-work life may blur. Extreme living conditions such as spaceflight can result in increased stress over time, negatively impact mood and well-being, decrease team cohesion and increase conflict, deteriorate task performance, and potentially reduce mission success [1]. With no breaks in their isolated and confined environment possible, living with a messy, inconsiderate crewmember can add to the stress. Alternatively, crews with good group living skills may support one another, mitigating the negative effects of the extreme environment. There was no direct measure of group living skills. This work sought to fill this measurement gap and collect data related to group living in isolated, confined, extreme (ICE) environments. METHODS Group living skills as an astronaut competency area were developed with the input of experts familiar with ICE environments. Distinct aspects of this competency were reviewed and discussed by a NASA-invited group of spaceflight experts in 2015 to identify individual and team behavioral health and performance measures for operational environments. This work resulted in a 5-item measure focused on group living experiences with each crewmember (or the crew as a whole). A 6th item asks whether an individual would go on another mission with a particular crewmember or crew as a measure of future-oriented group living, or team viability. The measure was deployed in 24 teams living and working together in isolated and confined environments (e.g., International Space Station, space mission simulation analogs). RESULTS & DISCUSSION In this presentation, we will summarize results which indicate the Group Living Skills (GLS) Survey is a reliable, valid, and operationally feasible measure. Reliability was evaluated in several ways. Two-way multilevel mixed models revealed strong repeated measures reliability (ICC2 = .902, Omega between = .954). Reliability of change within teams was strong (Rc = .81). Factor analysis showed a consistent two-factor structure when individuals rated either the whole crew, all individuals, just peers, or a focal roommate. The latter used a sociometric approach to rating the GLS of the roommates. The two factors were tidiness and being considerate of others. We assessed the criterion-related validity of GLS, by examining GLS operationalized as the team-level aggregated GLS Survey scores as a predictor of team viability, team cohesion, and team performance. We used generalized mixed models to account for the repeated measures and longitudinal data. The marginal R2 change was used to determine the extent to which GLS were related to the team outcomes while controlling for mission day and campaign. Results suggested GLS was strongly related to team viability (marginal R2 change = .40), team cohesion (marginal R2 change = 0.28), social cohesion (marginal R2 change = 0.25), and moderately related to task cohesion (marginal R2 change = 0.18). GLS scores had a small relationship with team performance (marginal R2 change = .08). Results support GLS as a measure that can be used to capture group living skills of crews who live and work together in ICE. Because the items were written to be broadly applicable, less extreme environments with teams living and working together for some length of time also benefit from this measure (e.g., college roommates, camps). See Landon et al. (2024) for full results [2]. SUMMARY We report reliability and validity evidence for a new measure that assesses the Group Living Skills for teams that live and work in operational environments such as spaceflight.

J C W Miller↗

Performance of Gas-Engine Driven Heat Pump Unit

Air-conditioning (cooling) for buildings is the single largest use of electricity in the United States (U.S.). This drives summer peak electric demand in much of the U.S. Improved air-conditioning technology thus has the greatest potential impact on the electric grid compared to other technologies that use electricity. Thermally-activated technologies (TAT), such as natural gas engine-driven heat pumps (GHP), can provide overall peak load reduction and electric grid relief for summer peak demand. GHP offers an attractive opportunity for commercial building owners to reduce electric demand charges and operating expenses. Engine-driven systems have several potential advantages over conventional single-speed or single-capacity electric motor-driven units. Among them are variable speed operation, high part load efficiency, high temperature waste heat recovery from the engine, and reduced annual operating costs (SCGC 1998). Although gas engine-driven systems have been in use since the 1960s, current research is resulting in better performance, lower maintenance requirements, and longer operating lifetimes. Gas engine-driven systems are typically more expensive to purchase than comparable electric motor-driven systems, but they typically cost less to operate, especially for commercial building applications. Operating cost savings for commercial applications are primarily driven by electric demand charges. GHP operating costs are dominated by fuel costs, but also include maintenance costs. The reliability of gas cooling equipment has improved in the last few years and maintenance requirements have decreased (SCGC 1998, Yahagi et al. 2006). Another advantage of the GHP over electric motor-driven is the ability to use the heat rejected from the engine during heating operation. The recovered heat can be used to supplement the vapor compression cycle during heating or to supply other process loads, such as water heating. The use of the engine waste heat results in greater operating efficiency compared to conventional electric motor-driven units (SCGC 1998). In Japan, many hundreds of thousands of natural gas-driven heat pumps have been sold (typically 40,000 systems annually) (Yahagi et al. 2006). The goal of this program is to develop dependable and energy efficient GHPs suitable for U.S. commercial rooftop applications (the single largest commercial product segment). This study describes the laboratory performance evaluation of an integrated 10-ton GHP rooftop unit (a 900cc Daihatsu-Aisin natural gas engine) which uses R410A as the refrigerant (GEDAC No.23). ORNL Thermally-Activated Heat Pump (TAHP) Environmental Chambers were used to evaluate this unit in a controlled laboratory environment.

03 NATURAL GAS↗

Encapsulation and backsheet adhesion metrology for photovoltaic modules

Photovoltaic modules are designed to operate for decades in terrestrial environments. However, mechanical stress, moisture, and ultraviolet radiation eventually degrade protective materials in modules, particularly their adhesion properties, eventually leading to reduced solar cell performance. Despite the significance of interfacial adhesion to module durability, currently there is no reliable technique for characterizing module adhesion properties. We present a simple and reproducible metrology for characterizing adhesion in photovoltaic modules that is grounded in fundamental concepts of beam and fracture mechanics. Using width-tapered cantilever beam fracture specimens, interfacial adhesion was evaluated on relevant interfaces of encapsulation and backsheet structures of new and 27-year-old historic modules. The adhesion energy, Gc [J/m 2 ], was calculated from the critical value of the strain energy release rate, G, using G = βP 2 , where β (a mechanical and geometric parameter of the fracture specimen) and P (the experimentally measured critical load) are constants. Under some circumstances where testing may result in cracking of brittle layers in the test specimen, measurement of the delamination length in addition to the critical load was necessary to determine G. Relative to new module materials, backsheet adhesion was 95% and 98% lower for historic modules that were exposed (operated in the field) and unexposed (stored on-site, but out of direct sunlight), respectively. Encapsulation adhesion was 87-94% lower in the exposed modules and 31% lower in the unexposed module. As a result, the metrology presented here can be used to improve module materials and assess long-term reliability.

14 SOLAR ENERGY↗

Design and Implementation of Replicated Object Layer

One of the widely used techniques for construction of fault tolerant applications is the replication of resources so that if one copy fails sufficient copies may still remain operational to allow the application to continue to function. This thesis involves the design and implementation of an object oriented framework for replicating data on multiple sites and across different platforms. Our approach, called the Replicated Object Layer (ROL) provides a mechanism for consistent replication of data over dynamic networks. ROL uses the Reliable Multicast Protocol (RMP) as a communication protocol that provides for reliable delivery, serialization and fault tolerance. Besides providing type registration, this layer facilitates distributed atomic transactions on replicated data. A novel algorithm called the RMP Commit Protocol, which commits transactions efficiently in reliable multicast environment is presented. ROL provides recovery procedures to ensure that site and communication failures do not corrupt persistent data, and male the system fault tolerant to network partitions. ROL will facilitate building distributed fault tolerant applications by performing the burdensome details of replica consistency operations, and making it completely transparent to the application.Replicated databases are a major class of applications which could be built on top of ROL.

Koka, Sudhir↗

RHIC stochastic cooling motion control

Relativistic Heavy Ion Collider (RHIC) beams are subject to Intra-Beam Scattering (IBS) that causes an emittance growth in all three-phase space planes. The only way to increase integrated luminosity is to counteract IBS with cooling during RHIC stores. A stochastic cooling system for this purpose has been developed, it includes moveable pick-ups and kickers in the collider that require precise motion control mechanics, drives and controllers. Since these moving parts can limit the beam path aperture, accuracy and reliability is important. Servo, stepper, and DC motors are used to provide actuation solutions for position control. The choice of motion stage, drive motor type, and controls are based on needs defined by the variety of mechanical specifications, the unique performance requirements, and the special needs required for remote operations in an accelerator environment. In this report we will describe the remote motion control related beam line hardware, position transducers, rack electronics, and software developed for the RHIC stochastic cooling pick-ups and kickers.

43 PARTICLE ACCELERATORS↗

Improving the performance of stainless-steel DC high voltage photoelectron gun cathode electrodes via gas conditioning with helium or krypton

Gas conditioning was shown to eliminate field emission from cathode electrodes used inside DC high voltage photoelectron guns, thus providing a reliable means to operate photoguns at higher voltages and field strengths. Measurements and simulation results indicate that gas conditioning eliminates field emission from cathode electrodes via two mechanisms: sputtering and implantation, with the benefits of implantation reversed by heating the electrode. We have studied five stainless steel electrodes (304L and 316LN) that were polished to approximately 20 nm surface roughness using diamond grit, and evaluated inside a high voltage apparatus to determine the onset of field emission as a function of voltage and field strength. The field emission characteristics of each electrode varied significantly upon the initial application of voltage but improved to nearly the same level after gas conditioning using either helium or krypton, exhibiting less than 10 pA field emission at -225 kV bias voltage with a 50 mm cathode/anode gap, corresponding to a field strength of ~13 MV/m. Finally, field emission could be reduced with either gas, but there were conditions related to gas choice, voltage and field strength that were more favorable than others.

BastaniNejad, M.↗

Validation of fault-free behavior of a reliable multiprocessor system - FTMP: A case study

A program of experiments has been conducted at NASA-Langley to test the fault-free performance of a Fault-Tolerant Multiprocessor (FTMP) avionics system for next-generation aircraft. Baseline measurements of an operating FTMP system were obtained with respect to the following parameters: instruction execution time, frame size, and the variation of clock ticks. The mechanisms of frame stretching were also investigated. The experimental results are summarized in a table. Areas of interest for future tests are identified, with emphasis given to the implementation of a synthetic workload generation mechanism on FTMP.

Clune, E.↗

Improving Reliability of High Power Quasi-CW Laser Diode Arrays Operating in Long Pulse Mode

Operating high power laser diode arrays in long pulse regime of about 1 msec, which is required for pumping 2-micron thulium and holmium-based lasers, greatly limits their useful lifetime. This paper describes performance of laser diode arrays operating in long pulse mode and presents experimental data of the active region temperature and pulse-to-pulse thermal cycling that are the primary cause of their premature failure and rapid degradation. This paper will then offer a viable approach for determining the optimum design and operational parameters leading to the maximum attainable lifetime.

Amzajerdian, Farzin↗

Promoting Robust Design of Diode Lasers for Space: A National Initiative

The Diode-laser Array Working Group (DAWG) is a national-level consumer/provider forum for discussion of engineering and manufacturing issues which influence the reliability and survivability of high-power broad-area laser diode devices in space, with an emphasis on laser diode arrays (LDAs) for optical pumping of solid-state laser media. The goals of the group are to formulate and validate standardized test and qualification protocols, operational control recommendations, and consensus manufacturing and certification standards. The group is using reliability and lifetime data collected by laser diode manufacturers and the user community to develop a set of standardized guidelines for specifying and qualifying laser diodes for long-duration operation in space, the ultimate goal being to promote an informed U.S. Government investment and procurement strategy for assuring the availability and durability of space-qualified LDAs. The group is also working to establish effective implementation of statistical design techniques at the supplier design, development, and manufacturing levels to help reduce product performance variability and improve product reliability for diodes employed in space applications

Tratt, David M.↗