Search NASA⌕ Search

SEARCH · Search NASA

Results for “Retrofitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Applying the Transactive Systems Business Value Model to IRP

As part of the Transactive Systems Program at Pacific Northwest National Laboratory, a value modeling system was developed to support the evaluation of transactive systems. The technique is general enough to be applied outside transactive systems and to demonstrate this capability, a project was undertaken to use this value modeling technique as a means for modeling the valuation process undertaken by vertically integrated utilities when undergoing integrated resource planning (IRP). IRP is the process by which vertically integrated utilities (those that both serve customers directly as well as manage and run generation assets to do so) regularly go through to demonstrate to their regulators that they have a plan to meet the expected future load of their customers in a least cost and compliant manner. Traditionally this has been primarily an issue of how many and of which types of power plants to build but increasingly has included alternative measures such as demand response programs. Increasingly, environmental regulations play a significant role in both determine what types of power plants can be built under current regulations as well as what retrofits or upgrades need to be made to existing plants to allow them to continue to operate. Two use-case diagrams were constructed, one showing the showing the process by which IRP is carried out and another showing how a vertically integrated utility procures the resources it requires to meet load now and in the future. These diagrams help clarify the difference and provide a high-level outline of the two processes. A class diagram was constructed to clearly define the types of actors that would be considered in this model and the relationships between them. This diagram tacitly indicates which types of actors are and are not included in the model which provides significant guidance in defining the scope of the model. The relationship between the classes/actors provides further indication of what areas of the model have higher levels of detail and by implication bear more significance in modeling the system. Using the classes/actors defined in the class diagram, a business value diagram was constructed that defines the key value streams exchanged between the actors. This diagram provides a clear expression of the business case of the vertically integrated utility and who its counterparties are during the process of meeting load. These value streams have not only to do with meeting the load but doing so in a manner that meets environmental regulations. Increasingly, IRPs have three key metrics to evaluate a given plant to meet load: net present value of revenue required, emissions, and renewable energy credits. From this business value diagram, more detailed activity diagrams were formed that focus on a few of the key value stream exchanges, showing the process by which each party accrues value. These diagrams provide insight into the timing and sequence of the interactions in a way that the business value diagrams did not. The transactive value model was found to be highly compatible with IRP and provided a clear, simple model of the analysis done during IRP and key metrics driving IRP decisions. In particular it highlighted a few key items that may or may not have been as clear prior to the development of the model. Specifically, the role of the environmental regulations has become increasingly important and two of the three key metrics by which IRPs are typically evaluated are environmentally focused. Additionally, though generally not acknowledged, the role of the investor was included in this model as they are an essential source of capital in building new power plants and cannot be ignored when defining the business case of the vertically integrated utility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NRT Design Verification Test Plan

The National Rotor Testbed (NRT) design verification experiment is the first test of the new NRT blades retrofitted to the existing Vestas V27 hub and nacelle operated at the Sandia Scaled Wind Farm Technology (SWiFT) facility. This document lays out a plan for pre-assembly, ground assembly, installation, commissioning, and flight testing the NRT rotor. Its performance will be quantified. Adjustments to torque constant and collective blade pitch will be made to ensure that the tip-speed-ratio and span-wise loading are as close to the NRT design as possible. This will ensure that the NRT creates a scaled wake of the GE 1.5sle turbine. Upon completion of this test, the NRT will be in an operational state, ready for future experiments.

17 WIND ENERGY↗

Low-Cost Multi-Modal Wireless Sensor Platform for Smart Buildings

Buildings consume 73% of the energy produced in the United States [1, 2]. Advanced sensors, controls, and communications have the potential to reduce the energy consumption of buildings by 20–40% [3, 4]. Currently, installation and wiring costs for sensors are quite high, making it cost-prohibitive for building managers to deploy large quantities of advanced sensors [5]. Wireless sensors have recently been deployed in buildings to provide the information necessary for optimal control of heating, ventilation, and air-conditioning and lighting systems [6, 7]. Wireless sensors have the unique advantage of being suitable for easily retrofitting existing buildings at a minimal labor cost, and the flexibility to be placed at optimal, observable locations. However, current commercially available wireless sensors are still very expensive ($150–300/node). Thus, revolutionary technological improvements in wireless sensors are required to promote inherently low-cost manufacturing for building applications to successfully exploit the energy efficiency opportunities in buildings.In this report, we present the efforts carried out at Oak Ridge National Laboratory and Molex Inc. toward exploring the design, implementation, and performance evaluation of low-cost, self-powered wireless sensors—including temperature, relative humidity, occupancy, and indoor air quality sensors—to enable advanced control applications that reduce energy consumption in buildings. Our focus is to demonstrate a novel multifunctional sensor platform that will evolve with advances in materials technology, low-cost printing techniques, nano-antennas, and co-integration of monitoring, control, and communication circuitry. We also present a low-power and bandwidth-efficient wireless communication technology that can be driven by energy harvesting in self-powered wireless sensors. It is based on code-phase-shift keying (CPSK) spread-spectrum signaling that improves both transmitter range and power consumption. The objective is to minimize the number of components within the wireless transceiver and reduce power consumption to allow sensor networks powered by energy harvesting, thus eliminating the expense and effort of periodically replacing the sensor batteries. Current state-of-the-art radio technologies have demonstrated 25–30 mA current consumption for the transmitter. Our prototype demonstrations lowered the consumption to 4 mA using spread-spectrum-based CPSK so that solar cells can be used with indoor lighting to recharge a battery indefinitely. Therefore, the system can run with no attention or maintenance for the life of the components, which is expected to be 20 years. The developed technology has the potential to generate fully printable wireless sensors with costs on the order of $1–10/node.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficiency-Optimized Dual Fuel Engine with In-Cylinder Gasoline/CNG Blending

The objective of the proposed project is to demonstrate targeted blending of gasoline and natural gas as a means to reduce petroleum consumption of light-duty spark-ignition engine vehicles by at least 50%. This goal will be achieved through petroleum displacement with natural gas (NG) combined with a relative engine efficiency improvement in excess of 10% while meeting retrofitability requirements with an anticipated payback period of less than 36 months. Further through NG direct injection (DI) a 10% improvement in power density over the PFI baseline will be demonstrated. The proposed project employs a sound R&D approach and combines experimental work with state-of-the-art computational modeling to be able to demonstrate the ambitious project goals. The project spans a 30 month period and is divided in 3 phases with the initial phase focused on experimental characterization of the gaseous jet structure of the high-pressure NG DI injector which is used to validate the 3D-CFD simulation tool. The phase also includes an experimental demonstration of the fundamental feasibility of the proposed dual-fuel approach on an automotive single-cylinder research engine. The scope of the second phase includes optimization of the combustion system by means of virtual design combined with 3D-CFD analysis. The resulting optimized combustion system will be built and experimentally evaluated by the end of the 12 month period. The third and final phase expands the scope by integrating the engine results in a vehicle level simulation tool with the objective of developing an optimized engine control strategy that maximizes the efficiency benefits attainable with the limited on-board NG supplies. A detailed cost analysis to verify that the 36 month amortization period requirement is met will conclude the proposed effort.

42 ENGINEERING↗

Coatings and Process Development for Reduced Energy Automotive OEM Manufacturing Final Technical Report

The project team successfully developed a new low-temperature coating system that achieves performance, durability, and appearance requirements for an Automotive Original Equipment Manufacturer paint system. This coating system is compatible with current OEM manufacturing paint lines, allowing application to existing manufacturing locations. The new coating system can also save capital expenses for new lines or renovations of existing lines. The new paint system enable energy savings and operational expense savings. DURR has designed a reference system that can serve as the starting point for new or retrofit paint line upgrades to this low temperature coating system. NDSU has developed and demonstrated the value of high-throughput screening for polymers and cure performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CO 2 Capture with Ionic Liquids Involving Phase Change (Final Report)

Coal-fired power plants provide nearly 50% of all electricity in the U.S. While coal is a cheap and abundant natural resource, its continued use contributes to rising carbon dioxide (CO 2 ) levels in the atmosphere. Capturing and storing this CO 2 would reduce atmospheric greenhouse gas levels while allowing power plants to continue using inexpensive coal. Carbon capture and storage represents a significant cost to power plants that must retrofit their existing facilities to accommodate new technologies. Reducing these costs is the primary objective of ARPA-E's carbon capture program. Researchers at the University of Notre Dame and their partners at Matric developed a new CO 2 capture process that uses materials that we call Phase Change Ionic Liquids (PCILs). PCILs are solid at the temperature of the CO 2 absorption but change to liquid when they bind with CO 2 . The PCILs have a high capacity for CO 2 at post-combustion flue gas pressures and temperatures because of a chemical reaction between the CO 2 and the PCIL. Upon heating, the CO 2 is released, and the PCILs re-solidify. The heat released in the solidification process reduces the amount of external heat that must be added. As with conventional CO 2 capture processes, the PCIL process has an absorber and a regenerator. Computer simulation of the process enabled calculation of viable process conditions and power needs. The main concepts of the process were demonstrated using lab-scale apparatus. Capture of CO 2 was carried out using a sieve tray column in continuous mode. Desorption of the CO 2 in the regenerator occurred while the liquid droplets solidified. The key to making this process viable was the use of a mixture of the complexed liquid with the unreacted solid particles in the absorber. This mixture formed a well-behaved slurry that flowed readily. Therefore, handling of solid particles is avoided in the process. Parasitic power was decreased by 55% from the amount required by the monoethanolamine (MEA) process. For the PCIL process, parasitic power is only 23% of the net power generated by the plant, which is remarkably close to the 19% DOE target. The capital cost for the CO 2 capture unit is higher for the PCIL process than the MEA process. Nonetheless, the overall increase in the cost of electricity (COE) is dramatically lower - only 4.1¢/kWh for the PCIL process compared with 5.7¢/kWh for the MEA process. The cost of CO 2 avoided is $48/ton of CO 2 . As a result, we conclude that CO 2 capture with phase change ionic liquids is an exceedingly promising technology.

01 COAL, LIGNITE, AND PEAT↗

Experimental and numerical evaluations of the energy savings potential of thermally anisotropic composites

Previous numerical studies conducted in FY 17 showed that the application of thermally anisotropic composites (TACs) coupled with a heat sink/source can re-direct and reduce unwanted heat flows through exterior building walls, with associated reductions in envelope-generated heating and cooling loads in buildings. The numerical analyses included two-dimensional finite element models (FEM) of wall assemblies and whole-building modeling to estimate the annual reductions in wall-generated heating and cooling loads, and associated energy consumption. The FY17 study used combined FEM and EnergyPlus (E+) simulations of a typical two-story, single-family DOE prototype residential building model.1 We studied performance of several configurations of walls containing exterior continuous insulation and thermally anisotropic composites on the wall exterior. The study showed that annual energy cost savings of up to $270 are possible under Phoenix and Baltimore weather conditions, by retrofitting a baseline wall with an anisotropic composite. In the cases considered, the TAC consisted of three layers of aluminum foil-faced foam boards. In general, it was found that the anisotropic composites were effective in reducing cooling loads; more investigation on heating loads is needed. During FY 18, ORNL performed a series of laboratory tests of anisotropic composites and appropriate heat sink/source, validated the FEMs used for the FY17 numerical study using experimental data, and revisited the whole-building modeling. Wall prototypes were created and tested in ORNL’s large scale climate simulator (LSCS) under variable conditions approximating summer and winter time periods.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Commercial Carbon Capture and Storage (CCS) Prefeasibility Study at Rock Springs Uplift, Wyoming (Final Report)

To establish the potential of safe, long-term commercial-scale carbon capture & storage (CCS) in southwestern Wyoming, the University of Wyoming formed a CCS coordination team (CCT) to complete a Phase I CarbonSAFE pre-feasibility study adjacent to the region’s largest coal-fired power plant, the Jim Bridger Plant (JBP). The study’s primary objective was to evaluate the potential of storing 50+ million metric tons of anthropogenic carbon dioxide (CO 2 ) in stacked reservoirs over a period of 25 years. In addition, this integrated study evaluated related aspects of carbon capture utilization & storage (CCUS) at the study site, including: (1) the CO 2 character of post-combustion flue gas from JBP and the technical capacity for retrofitting proven commercial-scale CO 2 capture technology relative to CO 2 source character and technological constraints; (2) utilization of the existing CO 2 pipeline network in the immediate vicinity of JBP for enhanced oil recovery (CO 2 -EOR) and utilizing that network as part of a regional hub for CO 2 storage from other anthropogenic sources; (3) assessment of the challenges and benefits of meeting all of CarbonSAFE programmatic Phase I goals relative to Wyoming’s carbon management regulatory framework; and (4) assessment of the community and environmental factors that may impact CCS at JBP. With respect to storage, we analyzed the potential of stacked Mesozoic reservoirs at the study site, focusing on the Entrada and Nugget sandstones. The reservoir response to injection simulations varied greatly between formations, though they both were capable of CO 2 storage. The Entrada Sandstone is relative thin (~40’) and heterogeneous; storage using one injection and production well was limited to 1.2 Mt over 25 years at the study site. The Nugget Sandstone is much thicker (> 400’) and generally homogeneous; storage using one injection and production well approached 15.0 Mt over 25 years; this scenario suggests that the storage potential in the Nugget Sandstone is close to the estimated P90 calculation of 9.6 Mt/mi 2 as models indicate a storage potential of 8.3 Mt/mi 2 at saturation. Both reservoirs’ storage capacity benefited greatly from coupling an injection well with an offset production well; total storage capacity increased and reservoir pressure stayed below critical thresholds. This indicates that implementing a pressure management strategy at the study site would optimize storage and decrease risk. Seals associated with the targeted reservoirs were shown to be capable of retaining the potential storage volumes, and the site benefits from multiple seal redundancies (i.e. > 7,000’ of seal formations). Furthermore, assessment of different reservoir variables (e.g., fluid composition, pressure, etc.) indicates all reservoirs at the study site are isolated. Storage assessments from Mesozoic reservoirs were coupled with simulations from the site’s Paleozoic reservoirs (the Weber Sandstone and Madison Limestone), which were the focus of previous study. The fully integrated stacked reservoir pre-feasibility studies suggest that the Nugget and Madison formations alone could safely store 50 million metric tons of CO 2 within the study site. Furthermore, both formations are true saline reservoirs near JBP, making them ideal target reservoirs for CO 2 sequestration. Analysis of Wyoming’s laws and regulations confirm that the State has a favorable policy environment for CCS/CCUS. The project’s economic models estimated that the following revenues collectively are sufficient to finance the project over its lifespan if CO 2 utilization is coupled with CCS via the following strategies: (1) sales of CO 2 for EOR (approximately $69 million/year); (2) use of CO 2 tax credits such as amended §45Q and §48A (approximately $484 million total); and (3) sales of low-carbon electricity and marketable carbon offset/credits into carbon-constrained markets (approximately $11-$17 million/year) to West Coast consumers. These revenue estimates are broadly consistent with other studies that concluded arbitrage in JBP retail electricity sales between California and Wyoming could help to support the cost of deploying CCS at JBP. The models also indicate that maintaining a successful business case for long-term CCS -- wherein associated capture, transportation and operational costs are fully addressed at JBP -- is reliant on numerous external factors that complicate predictions. This study suggests that this site meets the CarbonSAFE program’s requirements of being able to feasibly store 50+ million metric tons of CO 2 over 25 years within the site’s stacked reservoirs, especially if coupled with pressure management strategies. This study suggests that the Nugget Sandstone and the Madison Limestone are two of the best reservoirs in the State with respect to overall storage capacity. In addition, the site’s proximity to existing CO 2 transportation networks, CO 2 -EOR opportunities, ability to sell to markets that value low-carbon electricity, Wyoming’s existing carbon regulatory framework, and a public that is well-educated with respect to energy markets and issues collectively increase the potential for implementing commercial-scale CCS adjacent to the JBP. With respect to the available technical and non-technical site data, and the reservoir quality at the study site, we suggest that this site is capable of moving directly into Phase III of the CarbonSAFE program.

01 COAL, LIGNITE, AND PEAT↗

Weatherization Crew Leader Job Task Analysis

The US Department of Energy's Guidelines for Home Energy Professionals project maintains job task analyses for jobs in the Weatherization Assistance Program and home performance industry. One of those jobs is Crew Leader, defined as: 'A Crew Leader is responsible for supervising and assisting in the retrofitting activities specified in the scope of work. He or she is responsible for interacting with the client plus managing personnel and materials on the job site in a safe and effective manner. The Crew Leader is responsible for quality control, testing procedures, documentation, and conducting a walk through in preparation that all work is completed in a satisfactory manner.' This document is an updated version of the Crew Leader job task analysis.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Making Coal Relevant for Small Scale Applications: Modular Gasification for Syngas/Engine CHP Applications in Challenging Environments

This Front-End Engineering Design (FEED) study is funded by the US Department of Energy (DOE), and managed by the National Energy Technology Laboratory (NETL) through a Cooperative Agreement awarded to the University of Alaska Fairbanks (UAF) to perform a technical and cost study for the design and installation of a Hamilton-Maurer International (HMI) gasifier for generating a clean syngas for firing in reciprocating engines. An existing diesel engine generator (DEG) and a commercially available spark ignition engine are used to generate electricity with the low-Btu syngas. Other than the HMI gasifier, only commercially available technologies were assumed for this study. An important objective of this design study was to estimate capital and operating costs of small modular coal and coal/biomass fired generating units to provide wind regulation services. Although this study is based on retrofitting an existing coal fired power plant with the HMI gasifier, sufficient data was developed to characterize greenfield units. The original concept was to provide clean syngas and tars/oils from the gasification process to the existing Colt-Pielstick PC2.6B diesel engine generator (9.6 MWe) installed at the UAF Atkinson Power Plant. The intent was to convert the diesel engine to operate in a dual fuel mode, firing both syngas and tars/oils. As the project progressed, Fairbanks Morse Engine (FME), current licensee for the Colt-Pielstick engine line, was not able to develop a modification package for the engine to allow for syngas firing. Although this type of modification is available for firing natural gas, the capability does not extend to syngas. Western Energy Systems, distributor for Innio Jenbacher, was able to offer the Jenbacher Model JMS620 engine. After review of available options, the project team selected a design configuration using two Jenbacher engines rated at 1965 kWe each to fire the syngas, with the oils/tars directed to the Colt Pielstick diesel to be blended with ultra-low sulfur diesel oil (ULSD). The Jenbacher engines are expected to operate at continuous base load, with some load-following ability, while the existing diesel engine will operate in grid support service, with loads varying from a nominal 25% to 100%. An annual capacity factor for the diesel engine is projected to be between 50% and 60%. The overall gasifier and gas clean-up system is sized to produce enough syngas to adequately fuel three Jenbacher Engines for a nominal power output of 5.9 MWe, but this study assumes that only two Jenbacher engines will be installed due to space constraints in the Atkinson Power Plant, and because of expected air emission permit limitations. There is still potential that the excess syngas capacity equivalent to about 2 MWe could be used as supplemental fuel for the DEG. The exhaust from the Jenbacher engines is passed through heat recovery units to generate low pressure steam, thereby providing a significant portion of the steam required for operating the gasifier. The overall performance of the HMI gasifier/engine configuration is summarized as follows: 1) Overall electric efficiency, Jenbacher and diesel engines, based on gasifier fuel production (syngas and pyrolysis liquids) is 35.2% LHV, 2) Overall cogenerating efficiency (electricity plus steam), based on gasifier fuel production (syngas and pyrolysis liquids) is 54.8% LHV, 3) Overall electric efficiency, Jenbacher and diesel engines, based on coal input, is 29.6% LHV, and 4) Overall cogenerating efficiency, electricity plus steam, based on coal input is 46.0%. This project is estimated to have a Bare Erected Cost (BEC) of $\$$ 33.4 million and a Total Plant Cost (TPC) of $\$$ 45.7 million. Based on the original scope, sending both the clean syngas and the oils and tars to the existing diesel engine, the BEC and TPC values would have been $\$$ 23.3 million and $\$$ 32.1 million, respectively. A variable Cost of Electricity (COE) is calculated to reflect only those costs that will be incurred by incremental operation of the system for the HMI gasifier/Jenbacher engine combination. Operation of the diesel engine is determined separately. The variable COE values are: Case 1: 100% Usibelli Coal: (a) HMI gasifier/Jenbacher Engines -- 8.3 cents/kWh; (b) Diesel Engine -- 20.2 cents/kWh, and Case 2: 80% Usibelli Coal + 20% wood chips (proportion based on Btu input, LHV basis): (a) HMI Gasifier/Jenbacher -- 13.7 cents/kWh; (b) Diesel Engine -- 20.2 cents/kWh. The incremental cost of operating the gasifier/Jenbacher system increases with co-firing of wood chips due to the high cost of this material, over five times as costly as Usibelli coal delivered to the Atkinson Power building. The diesel cost is constant as the oils and tars are priced at the same value as the ULSD for the purposes of fueling the diesel engine. Section 8 of this report provides details of the O&M costs. The overall power system is configured to be modular and scalable to provide a wide range of generating capacity using the same components. This allows for reduction in cost, risk, schedule time to engineer and construct, and provides some degree of repeatability for air permitting.

01 COAL, LIGNITE, AND PEAT↗

An Assessment of Hydropower Environmental Mitigation Costs

This report provides an assessment of environmental mitigation costs for hydropower projects across the United States (U.S.) based on data extracted from Environmental Assessments (EA) submitted to the Federal Energy Regulatory Commission (FERC). EAs are required by the Federal Power Act (FPA) for hydropower license and relicense applications to weigh the “power” and “non-power” (i.e. environmental) benefits of their development and operation. For this analysis, we collected data from 184 EA documents reviewed by FERC between 1996 and 2018, and created a database of environmental protection, mitigation, and enhancement (PM&E) measures with their associated economic information. The data cover two hydropower relicense categories—103 Relicensed Conventional Hydropower Dams (RCHD) and 6 Relicensed Pumped Storage Hydropower (RPSH) projects—and three new development categories—57 hydropower retrofits at Non-Powered Dams (NPD), 11 New Stream-Reach Development (NSD) projects and 6 Pumped Storage Hydropower (NPSH) projects. For the analysis, we classify the PM&E measures into 11 Tier 1 categories. We evaluated capital and operations & maintenance (O&M) costs of PM&E measures on a $\$$/kW basis by project type and mitigation category, as well as their share in the total project levelized cost of energy (LCOE).

13 HYDRO ENERGY↗

Ultra Efficient Light Duty Powertrain with Gasoline Low Temperature Combustion (Final Report)

This document details the work completed during Project DE-EE0006839 ‘Ultra Efficient Light Duty Powertrain with Gasoline Low Temperature Combustion’. All tasks from the project’s Statement of Project Objectives are discussed. Final demonstration data is also presented and discussed. Further project details can be found in the Quarterly Technicial Reports that were submitted during the course of the project and are stored on the EERE Project Management Center Website. The goal of this project was to develop, implement and demonstrate a low temperature combustion approach called Gasoline Direct Injection Compression Ignition (GDCI) that provides high thermal efficiency with low NOx and PM emissions. The project target was to demonstrate a 35% fuel economy improvement over the baseline vehicle while meeting Tier 3 emissions levels. At the start of this project, GDCI was a moderately mature combustion technology, due in large part to advances made during a Delphi Technologies program funded through an earlier Department of Energy Advanced Technology Powertrains (ATP) opportunity; under that earlier contract, DE-EE0003258, Delphi Technologies assembled a team with complementary industrial and academic experience, and led this team to advance the technology from the original fundamental work to the state of art embodied by a first-generation (Gen 1) multi-cylinder GDCI engine. Key activities during that project centered on engine and combustion chamber design, and development of fuel injection equipment, valvetrain and advanced controls. Performance results with the Gen 1 engine in a development vehicle demonstrated that GDCI had the capability to operate using Low Temperature Combustion (LTC) over a broad speed-load range. Based on benchmarking work, efficiency for the Gen 1 GDCI engine compared favorably overall to production light-duty diesel engines. The second DOE funded project, DE-EE0006839, focused on a number of technical risks and issues that were left to be resolved for GDCI to become a production-viable technology. These risks were:GDCI combustion system refinement to achieve near-ideal air/fuel mixture preparation for high efficiency and low HC and CO emissions; Transient control development for low temperature combustion with high EGR levels during real-world transient driving maneuvers and over a broader range of ambient conditions; Aftertreatment system design that is effective in dealing with the low-temperature challenges of a highly efficient engine. The project was executed in two phases. Phase 1 leveraged the development vehicle from the Advanced Technologies Powertrain 1 (ATP1) project, DE-EE0003258. That vehicle was used as an initial test bed in the development of a high performance low temperature exhaust aftertreatment system. The vehicle was also used to develop calibration refinements for improved exhaust emissions and fuel efficiency. Samples of a new GDCI development level engine, called Gen2 GDCI (and developed outside of the first DOE funded project), were also used during Phase 1 to develop refined controller hardware and control algorithms, as well as improved sensors and actuators. The Gen2 engine was then retrofitted into the development vehicle from the ATP1 project and used for controls refinement and calibration of GDCI to achieve improved cold start, drivability and robustness to real world environments and fuel variations. During Phase 2 of the project, Gen3 versions of the GDCI engine were designed and built specifically for this project based on experience from the earlier engines. These engines were designed to be production-like in construction and, when combined with refined control systems and project specific low temperature exhaust aftertreatment, were intended to support the goal of meeting Tier 3 emissions levels at a vehicle level. Though great progress had been made advancing the GDCI combustion process, and despite extensive presentations of our work on the technology at various conferences and in direct meetings with automotive companies, none of the US domestic automotive OEMs had shown an interest in adopting this combustion process as part of their technology planning as the project approached the Go/No-Go point at the end of Budget Period 3. As a result of this low-level of interest both the US Department of Energy and Delphi Technologies received in this technology from domestic auto manufactures, Delphi Technologies elected a ‘No-Go’ status for the gate between Budget Period 3 and Budget Period 4 which terminated the project without spending any Budget Period 4 funds. The project team concluded that the dynamometer mapping of the most recent level of hardware, combined with the vehicle level simulation by Argonne National Laboratory, was sufficient to document the capabilities and potential of the combustion process without spending the time and money to do the controls development and full calibration necessary for a demonstration vehicle.

33 ADVANCED PROPULSION SYSTEMS↗

Techno-Economic Analysis and Evaluation of Wet FGD Wastewater Treatment Processes at Existing Plants

The United States Environmental Protection Agency (EPA) issued updated effluent limitation guidelines (ELGs) and standards for the steam electric power generation point source category in November 2015 to strengthen controls on wastewater discharges. Many of the public comments discussed concerns about reliability, and whether Best Available Technology Economically Achievable (BAT) has been adequately demonstrated under a variety of conditions; however, discussion of the cost of electricity (COE) impact of installing the technology on existing coal units was limited. To address the COE impact of installing processes to achieve compliance for wet flue gas desulfurization (FGD) wastewater at existing pulverized coal (PC) plants, this study focused on developing cost and performance estimates of multiple commercial technologies in various configurations, including alternative (non-BAT) compliance processes (e.g., zero valent iron) and overcompliance processes (e.g., brine concentration with fly ash conditioning). Exhibit ES-1 provides the net plant efficiency (η) and COE estimated for each of the selected process configurations in this study. Case 0 is the reference subcritical PC plant, which represents an existing unit discharging wet FGD wastewater to surface water. It is assumed that all existing capital assets are fully depreciated, such that any capital costs reflect only the cost of the wet FGD wastewater treatment systems and plant upgrades required to accommodate the retrofits.

54 ENVIRONMENTAL SCIENCES↗

Final Report on the Viability of Acoustic Techniques for Density and Mass Flow in Enrichment Plants

The primary purpose of this research is to study the viability of acoustic signatures and sensors that could support accurate, noninvasive, and unattended measurement of uranium hexafluoride (UF6) gas density and mass flow rate in situations representative of gaseous centrifuge enrichment plants (GCEP) under safeguards by the International Atomic Energy Agency. The measurement method under development can be readily retrofitted to the exterior of piping in existing systems, potentially facilitating acceptance by facility operators. The findings from the demonstration of a preliminary prototype design and first-generation analysis algorithms in this project will inform the safeguards community as to whether continued acoustic instrument and methods development are warranted. This project conducted two types of measurements, depending on the flow conditions of the gas. For static measurements, the focus is on understanding the acoustic properties at low pressure for non-flowing UF6. For flow measurements, the focus is on understanding the performance of the acoustic system in a simulation of a GCEP pipe using a surrogate gas under fully developed flow conditions. Testing with flowing UF6 was not considered because the cost of building a flowing UF6 system with flow similar to a GCEP was considerably greater than allocated project resources. This document summarizes the results of research conducted over the course of the project. Based on the results to date, the approach is seen to be promising with non-invasive acoustic measurements shown to be possible at the desired pressures. The project has demonstrated • 5% uncertainty of the UF6 gas density for static measurements at pressures relevant to GCEP operations over a 5-minute measurement window with a clear path forward to achieving considerably lower uncertainties over a two-hour period, • Measurements of flowing surrogate gases at pressures relevant to GCEP operations. However, additional research remains to be done to further develop the measurement approach and transition the technology for field use. These development needs include: • Understand the impact of flowing gas on gas density measurements, • Adding sensors and improving the measurement procedure, • Augmenting the data analysis methods by leveraging machine learning approaches, • Reevaluating uncertainty requirements for density and mass flow given observed Online Enrichment Monitor (OLEM) measurement uncertainties, • Designing a robust instrumentation package for field-testing, and • Evaluating measurement results to understand the potential impact on mass balance calculations within GCEP facilities.

42 ENGINEERING↗

Evaluation of Hydrogen Production Feasibility for a Light Water Reactor in the Midwest

Increased electricity production from renewable energy resources coupled with low natural gas prices has caused existing light-water reactor (LWRs) to experience ever diminishing returns from the electricity market. Via partnership among Idaho National Laboratory (INL), The National Renewable Energy Laboratory (NREL), Argonne National Laboratory (ANL), Exelon, and Fuel Cell Energy a techno-economic analysis on the viability of retrofitting existing pressurized water reactors (PWRs) to produce hydrogen (H2) via high temperature steam electrolysis (HTSE) has been conducted. Such integration would allow nuclear facilities to expand into additional markets that may be more profitable in the long-term. To accommodate such an integration, a detailed analysis of HTSE process operation, requirements, and flexibility was conducted. Technical analysis includes proposed nuclear system control scheme modifications to allow dynamic operation of the HTSE via both thermal and electrical connection to the nuclear plant. High fidelity Modelica simulations showcase the viability of such control schemes. However, due to limited knowledge of solid oxide fuel cell (SOFC) stack degradation due to thermal gradients; thermal cycling of the HTSE was not included. Therefore, the control schemes proposed are only utilized to re-distribute steam at startup and only the portion of electricity utilized in the electrolyzers is cycled. From the detailed analysis of the nuclear integration and the HTSE process design, a comprehensive cost estimation was conducted in the APEA and H2A models to elucidate capital and operational costs associated with the production, compression, and distribution of hydrogen from a nuclear facility. Alongside this costing analysis, market analyses were conducted by NREL and ANL on the electric and hydrogen markets respectively in the PJM interconnect. Utilizing the electricity data market projections in the PJM interconnect from NREL and hydrogen demand/pricing projections from ANL a five variable sweep over component capacities, discount rates, and hydrogen pricing was completed using the stochastic framework RAVEN (Risk Analysis Virtual ENVironment) through its resource dispatch plugin HERON (Heuristic Energy Resource Optimization Network). Each combination of variables was evaluated stochastically four times over a seventeen year timespan from 2026-2042 (inclusive) to determine the most economically advantageous solution. Following the five variable sweep an optimization was conducted about the best sweep point to determine optimal component sizing and setpoints. Results suggest positive gain is achievable at all projected hydrogen market pricing levels and at all discount rates. However, exact component sizing and net returns vary based on these values and if incorrect sizing is selected; major net losses can occur. The optimal result occurred with set points as follows: high hydrogen prices, the largest possible HTSE unit in the sweep set at 7.47 kg/sec [645.4 tpd], a contractual hydrogen market agreement 7.29 kg/sec [629.8 tpd], and a hydrogen storage size 115,188 kg. The analysis suggested that with a discount rate of 8%, a ΔNPV = 1.2 billion over the seventeen year span can be achieved. The results illuminate that by operating in multiple markets the nuclear facility is capable of avoiding sale of electricity during times of low electricity market pricing, while maintaining the ability to capitalize on the high electricity market pricing. It should be noted that the analysis conducted in this report is a differential cash flow analysis and as such does not present profit levels. Instead it highlights the net benefit between building and competing in the hydrogen market utilizing nuclear facilities and conducting business as usual in the electricity markets. Additionally, results presented in this report exhibit conservatism due to four key assumptions: Given the limited knowledge on SOFC stack degradation due to thermal gradients the high temperature steam electrolysis plant is not allowed to thermally cycle. This limitation decreases electricity generation capacity in the nuclear plant, reducing capacity payments and the maximum output to the electrical grid. This analysis considers building a separate hydrogen pipeline for use in the nuclear facility. Research is currently being conducted to determine if existing natural gas pipelines can accommodate direct hydrogen injection. If hydrogen can be integrated into existing natural gas pipelines then a capital savings of ~$19,000,000 per kg/sec [1 kg/sec = 86.4 tpd] of installed HTSE capacity could be realized. Fast transients in the electric grid are typically served by flywheels and electric batteries. With electrolysis only operation the nuclear plant can flex its electricity just as quickly. However, for this analysis, the ancillary services market has been neglected. Should the nuclear plant have the ability to operate in the ancillary services market during periods when it is producing hydrogen, an additional substantial income stream that would increase overall system profitability could be considered. Subsidies for non-emitting generation technologies are not introduced in the cash flow analysis, but instead are completed assuming zero subsidies. Profitability is based solely on electricity pricing. Electric pricing is assumed to never go negative. Instead, it is assumed overall system curtailment by the Independent System Operator (ISO) will occur in such a manner that pricing remains at or above zero. This assumption inflates the “business as usual” scenario, thus decreasing the ΔNPV calculated. If negative pricing scenarios continue to occur as they do today, one would expect a further increase in ΔNPV. Overall, results advocate that, through market diversification, nuclear power plants have the potential to substantially increase current profit margins, increase market penetration, and ultimately solidify their place as a mainstay in energy production.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Low-Cost Recuperative Heat Exchanger for Supercritical Carbon Dioxide Power Systems (Final Scientific/Technical Report)

Closed Brayton super-critical CO 2 power cycles are well suited to waste heat bottoming cycles, due to their increased efficiency and compactness, relative to Rankine steam bottoming cycles. Since waste heat applications would be retrofits, the power system compactness is important. To achieve high efficiency, these power cycles require high pressure recuperative type heat exchangers, of substantial heat duty. Current Printed Circuit Heat Exchangers (PCHE), originally developed for high pressure gas and oil applications, can be used as recuperators, but costs are higher than desired. Altex is developing a purpose-built high pressure and effectiveness recuperator to provide the reliability, compactness, performance and pressure capability of current recuperators, but at a reduced cost. The High Effectiveness Low Cost (HELC) recuperative heat exchanger design yields volume and weight metrics of .0024 m 3 /UA and 10.2 kg/UA, which are 4% and 77.3% below recuperator target metrics, respectively. A 50 kW test article was designed and fabricated. Performance tests on water and oil showed that the HELC design model could predict heat transfer, to within 10% of the measured value. This model was then used to project HELC performance, when operating on supercritical CO 2 . Besides performance tests, the test article was hydrostatically tested, for integrity at up to 4,000 psi pressure. At these conditions, some distortion of channels was encountered. To mitigate distortion, the inserts were redesigned and these results were used to project the cost of 500 kW and 5,083 kW HELC units. The cost metric for the 5,083 kW unit was determined to be $\$ $1,349/UA, which is 10% lower than the recuperator desired cost metric desired target of $\$ $1,500/UA. In addition, the 5,083 kW unit HELC cost of $\$ $61.09/kW is 33.6% lower than the $\$ $92/kW estimated cost for a PCHE. Hydrostatic pressure tests, at up to 4,000psi, showed that the unit did not leak. However, channels were distorted at this pressure differential. Design updates to minimize stress concentrations and distortion were prepared and analyzed, to show that distortion could be controlled, but to date tests have not been run to prove the design. Project results show the potential of the HELC approach, but more work is required to confirm this potential, at the larger scales of interest.

14 SOLAR ENERGY↗

Boosting Energy Efficiency and Economic Development through Chambers of Commerce (Final Technical Report)

The U.S. Department of Energy’s (DOE) Building Technology Office (BTO), in its mission to improve energy efficiency in commercial and residential buildings, recognized the unique challenges posed by small- and medium-sized commercial buildings. This project targeted these buildings by using a business-to-business model originally pioneered in Cleveland, Ohio, by the Greater Cleveland Partnership’s Council of Smaller Enterprises (COSE). Rather than attempting to take programs and materials designed for large commercial buildings and simply disseminate them to owners of small- and medium-sized buildings, COSE targeted the tenants and owners of these buildings directly through existing business partnership channels and built additional business partnerships with banks willing to finance cost-effective retrofits, and leveraging utility efficiency programs that enabled them to provide free audits via an established network of auditors. By delivering a customized message to their members and leveraging their connections in the local business community, Chambers of Commerce and other business-oriented organizations use their existing relationship and trust to deliver clear and concise messages about the opportunities, impacts, and value of energy efficiency investments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Preliminary Assessment of Post-Combustion Capture of Carbon Dioxide at the San Juan Generating Station [Draft]

This is a preliminary technical assessment of a proposal to retrofit the San Juan Generating Station in New Mexico, capturing the carbon dioxide (CO 2 ) generated by the power plant and transporting it via pipeline to the Permian Basin in Texas for use in CO 2 enhanced oil recovery (CO 2 -EOR). The assessment was conducted for the U.S. Department of Energy and relies on publicly available information, including a pre-feasibility study developed by Enchant Energy in partnership with Sargent & Lundy. It is focused on technical aspects of the project as related to the proposed capture of CO 2 , the proposed use/storage of CO2, and potential future options for use/storage of CO 2 in the Four Corners region.

02 PETROLEUM↗