Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Averaging Sampled Sensor Outputs To Detect Failures

Fluctuating signals smoothed by taking consecutive averages. Sampling-and-averaging technique processes noisy or otherwise erratic signals from number of sensors to obtain indications of failures in complicated system containing sensors. Used under both transient and steady-state conditions. Useful in monitoring automotive engines, chemical-processing plants, powerplants, and other systems in which outputs of sensors contain noise or other fluctuations in measured quantities.

Panossian, Hagop V.↗

Amplitude-Stabilized Oscillator for a Capacitance-Probe Electrometer

A multichannel electrometer voltmeter that employs a mechanical resonator maintained in sustained amplitude-stabilized oscillation has been developed for the space-based measurement of an Internal Electrostatic Discharge Monitor (IESDM) sensor. The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. Creating a stable oscillator from the mechanical resonator was achieved by employing magnetic induction for sensing the resonator s velocity, and forcing a current through a coil embedded in the resonator to produce a Lorentz actuation force that overcomes the resonator s dissipative losses. Control electronics employing an AGC loop provide conditions for stabilized, constant amplitude harmonic oscillation. The prototype resonator was composed of insulating FR4 printed-wireboard (PWB) material containing a flat, embedded, rectangular coil connected through flexure springs to a base PWB, and immersed in a magnetic field having two regions of opposite field direction generated by four neodymium block magnets. In addition to maintaining the mechanical movement needed for the electrometer s capacitor-probe transducer, this oscillator provides a reference signal for synchronous detection of the capacitor probe s output signal current so drift of oscillation frequency due to environmental effects is inconsequential.

Blaes, Brent R.↗

On the time lags of the LIGO signals

To date, the LIGO collaboration has detected three gravitational wave (GW) events appearing in both its Hanford and Livingston detectors. In this article we reexamine the LIGO data with regard to correlations between the two detectors. With special focus on GW150914, we report correlations in the detector noise which, at the time of the event, happen to be maximized for the same time lag as that found for the event itself. Specifically, we analyze correlations in the calibration lines in the vicinity of 35 Hz as well as the residual noise in the data after subtraction of the best-fit theoretical templates. The residual noise for the other two events, GW151226 and GW170104, exhibits similar behavior. A clear distinction between signal and noise therefore remains to be established in order to determine the contribution of gravitational waves to the detected signals.

79 ASTRONOMY AND ASTROPHYSICS↗

Bio‐Imaging quorum sensing signal molecules in a soil‐mimic gel

Rhizosphere, the narrow region surrounding plant roots directly influenced by root exudates and the root associated microbiome, plays an important role in plant productivity and the rhizosphere is well known for stimulating microbial metabolic activities. How microbial communities interact to form stable, metabolically interconnected functional communities is an area of intense interest. The question remains on how microbially produced secreted molecules that function as intercellular communication signals shape the structure and function of microbial communities. Our goal is to detect and quantify signal molecules produced by microbes or plants in the root‐soil environment, spatially and temporarily. As a proof‐of‐concept, we are imaging diffusible extracellular microbial metabolites involved in a bacteria‐bacteria communication process called quorum‐sensing. Quorum‐sensing relies on the accumulation of high concentrations of signal molecules in the environment to control bacterial gene expression, influencing rhizosphere colonization and plant health. Local concentration of quorum sensing molecules are determined using aptamer based sensors. Aptamers that can specifically bind the desired signal molecules are selected through SELEX and immobilized on the surface of nano‐porous membranes. Binding of the signal molecules and aptamer covered surface results in changes in surface charge distribution and steric hinderance and thus modifying the transmembrane ionic transport. Changes in transmembrane impedance can be measured through electrochemical impedance spectroscopy methods to monitor local concentrations of signal molecules. Sensor responses were determined for different concentrations of signal molecules and results showed detection of C4‐HSL in a soil‐mimic solution with K D of 10 nM. We demonstrate that the quorum‐sensing signal molecule C4‐homoserine lactone and (C4‐HSL) can rapidly diffuse in a soil‐mimic gel, providing evidence for our use of a soil‐mimic for further aptasensor development and validation. The sensors were then inserted into soil mimic gel for monitoring C4‐HSL diffusion and the resulted impedance changes were used to determine the C4‐HSL concentration at different positions in the gel. Measurements of local C4‐HSL concentrations variation and numerical solution of diffusion equation were used to create 4D images of C4‐HSL molecule diffusion in the soil‐mimic gel.

Jiang, Nianyu↗

Effect of filtering on noise and timing in nuclear particle detection

The relations between signal shaping, noise, and timing resolution in nuclear particle detection systems are examined in this paper. Mathematical analysis of five commonly used types of filters leads to numerical results for system noise components arising from sources in the preamplifier, detector, and bias resistors. These results are presented in the form of design curves for the various filters, showing the dependence of each output noise component on both the magnitude of the noise sources and the filter time constants. Three of the filters considered are simple RC types; the remaining two are combinations of delay lines and RC elements. The quantitative calculations specifically assume a silicon detector and a field-effect-transistor preamplifier. Those filters that exhibit bipolar step response are analyzed in terms of crossover timing resolution, based on the earlier noise calculations. Again, the results are summarized in sets of design curves for each filter. Finally, the comparative performance of the various filter types is discussed, and specific examples are given.

Gary, S. A.↗

Sensitive detection of narrowband pulses

Highly monochromatic signals, such as TV carriers, can be detected sensitively by using a narrow filter (b < or = 1 Hz) and performing power accumulation on its output. If instead a low-duty-cycle pulsed signal of the same total energy is present, the sensitivity of a square law device, followed by a thresholding operation (to eliminate most samples containing only noise), followed by the algorithm to be described, is greater by about 7 dB in typical cases. This is particularly interesting to SETI because such a pulsed signal is exactly what is sent by a rotating beacon with a directional antenna. Such a pulsed signal is, therefore, a good candidate for an extraterrestrial beacon. Software for detecting this signal type is now ready for field testing with the NASA Multichannel Spectrum Analyzer (MCSA).

NASA Discipline Number 52-60↗

Direct-detection optical communication with color coded pulse position modulation signaling

The performance characteristics of a direct-detection optical communication system which is based on a laser transmitter which produces single light pulses at selected nonoverlapping optical center frequencies are discussed. The signal format, called color coded pulse position modulation (CCPPM), uses more of the total available response bandwidth characteristics of the photodetector than does ordinary PPM signaling. The advantages of CCPPM signaling are obtained at the expense of an increased optical bandwidth of the transmitted signal and a more complicated transmitter and receiver structure. When the signal format is used in conjunction with block length Reed-Solomon codes, high data rates and reliable high-speed optical communications under conditions of optimal energy efficiency are obtained.

Davidson, F.↗

Digital Integrate-And-Dump Filter With Offset Sampling

Detection of weak signals improved slightly. Digital integrate-and-dump filter proposed for detection of weak rectangular-pulse signals corrupted by additive white Gaussian noise. Theory of filter takes account of degradation of performance caused by offset sampling.

Sadr, R.↗

THE IMPACT OF THE IONOSPHERE ON GROUND-BASED DETECTION OF THE GLOBAL EPOCH OF REIONIZATION SIGNAL

The redshifted 21 cm line of neutral hydrogen (H i), potentially observable at low radio frequencies (∼50–200 MHz), is a promising probe of the physical conditions of the intergalactic medium during Cosmic Dawn and the Epoch of Reionization (EoR). The sky-averaged H i signal is expected to be extremely weak (∼100 mK) in comparison to the Galactic foreground emission (∼10{sup 4} K). Moreover, the sky-averaged spectra measured by ground-based instruments are affected by chromatic propagation effects (∼tens of kelvin) originating in the ionosphere. We analyze data collected with the upgraded Broadband Instrument for Global Hydrogen Reionization Signal system deployed at the Murchison Radio-astronomy Observatory to assess the significance of ionospheric effects on the detection of the global EoR signal. The ionospheric effects identified in these data are, particularly during nighttime, dominated by absorption and emission. We measure some properties of the ionosphere, such as the electron temperature (T{sub e} ≈ 470 K at nighttime), magnitude, and variability of optical depth (τ{sub 100} {sub MHz} ≈ 0.01 and δτ ≈ 0.005 at nighttime). According to the results of a statistical test applied on a large data sample, very long integrations (∼100 hr collected over approximately 2 months) lead to increased signal-to-noise ratio even in the presence of ionospheric variability. This is further supported by the structure of the power spectrum of the sky temperature fluctuations, which has flicker noise characteristics at frequencies ≳10{sup −5} Hz, but becomes flat below ≈10{sup −5} Hz. Hence, we conclude that the stochastic error introduced by the chromatic ionospheric effects tends to zero in an average. Therefore, the ionospheric effects and fluctuations are not fundamental impediments preventing ground-based instruments from integrating down to the precision required by global EoR experiments, provided that the ionospheric contribution is properly accounted for in the data analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Pulsar timing sensitivity to very-low-frequency gravitational waves

We compute the sensitivity, constrained by instrumental, propagation, and other fundamental noises, of pulsar timing to very-low-frequency gravitational waves (GWs). Reaching predicted GW signal strengths will require suppression of time-of-arrival fluctuations caused by interstellar plasma turbulence and a reduction of white rms timing noise to < or approx. 100 ns. Assuming negligible intrinsic pulsar rotational noise, perfect time transfer from time standard to observatory, and stable pulse profiles, the resulting single-pulsar signal-to-noise ratio=1 sensitivity is limited by terrestrial time standards at h{sub rms}{approx}2x10{sup -16} [f/ (1 cycle/year)]-1/2 for f<3x10{sup -8} Hz, where f is the Fourier frequency and a bandwidth of 1 cycle/(10 years) is assumed. Since this sensitivity is comparable to predicted GW signal levels, a reliable detection will require substantial signal-to-noise ratio improvement via pulsar timing array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring results of the possibility on detecting cosmic ray particles by acoustic way

It has been demonstrated experimentally and theoretically that high energy particles produce detectable sounds in water. However, no one has been able to detect an acoustic signal generated by a high energy cosmic ray particle in water. Results show that transient ultrasonic signals in a large lake or reservoir are fairly complex and that the transient signals under water may arise mainly from sound radiation from microbubbles. This field is not explored in detail. Perhaps, the sounds created by cosmic ray particles hide in these ultrasonic signals. In order to develop the technique of acoustic detection, it is most important to make a thorough investigation of these ultrasonic signals in water.

Jiang, Y.↗

The eejj excess signal at the LHC and constraints on leptogenesis

We review the non-supersymmetric (Extended) Left-Right Symmetric Models (LRSM) and low energy E{sub 6}-based models to investigate if they can explain both the recently detected excess eejj signal at CMS and leptogenesis. The eejj excess can be explained from the decay of the right-handed gauge bosons (W{sub R}) with mass ∼ TeV in certain variants of the LRSM (with g{sub L}≠g{sub R}). However such scenarios can not accommodate high-scale leptogenesis. Other attempts have been made to explain leptogenesis while keeping the W{sub R} mass almost within the reach of the LHC by considering the resonant leptogenesis scenario in the context of the LRSM for relatively large Yukawa couplings. However, certain lepton number violating scattering processes involving the right-handed Higgs triplet and the right-handed neutrinos can stay in equilibrium till the electroweak phase transition and can washout the lepton asymmetry generated in the resonant leptogenesis scenario for mass range of W{sub R} as indicated by the CMS excess signal. Thus in such a scenario one needs to invoke post-sphaleron baryogenesis to explain the observed baryon asymmetry of the universe. Next, we consider three effective low energy subgroups of the superstring inspired E{sub 6} model having a number of additional exotic fermions which provides a rich phenomenology to be explored. We however find that these three effective low energy subgroups of E{sub 6} too cannot explain both the eejj excess signal and leptogenesis simultaneously.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A SENSITIVITY AND ARRAY-CONFIGURATION STUDY FOR MEASURING THE POWER SPECTRUM OF 21 cm EMISSION FROM REIONIZATION

Telescopes aiming to measure 21 cm emission from the Epoch of Reionization must toe a careful line, balancing the need for raw sensitivity against the stringent calibration requirements for removing bright foregrounds. It is unclear what the optimal design is for achieving both of these goals. Via a pedagogical derivation of an interferometer's response to the power spectrum of 21 cm reionization fluctuations, we show that even under optimistic scenarios first-generation arrays will yield low-signal-to-noise detections, and that different compact array configurations can substantially alter sensitivity. We explore the sensitivity gains of array configurations that yield high redundancy in the uv-plane-configurations that have been largely ignored since the advent of self-calibration for high-dynamic-range imaging. We first introduce a mathematical framework to generate optimal minimum-redundancy configurations for imaging. We contrast the sensitivity of such configurations with high-redundancy configurations, finding that high-redundancy configurations can improve power-spectrum sensitivity by more than an order of magnitude. We explore how high-redundancy array configurations can be tuned to various angular scales, enabling array sensitivity to be directed away from regions of the uv-plane (such as the origin) where foregrounds are brighter and instrumental systematics are more problematic. We demonstrate that a 132 antenna deployment of the Precision Array for Probing the Epoch of Reionization observing for 120 days in a high-redundancy configuration will, under ideal conditions, have the requisite sensitivity to detect the power spectrum of the 21 cm signal from reionization at a 3{sigma} level at k < 0.25 h Mpc{sup -1} in a bin of {Delta}ln k = 1. We discuss the tradeoffs of low- versus high-redundancy configurations.

79 ASTRONOMY AND ASTROPHYSICS↗

BRIGHT SOURCE SUBTRACTION REQUIREMENTS FOR REDSHIFTED 21 cm MEASUREMENTS

The H I 21 cm transition line is expected to be an important probe into the cosmic dark ages and epoch of reionization. Foreground source removal is one of the principal challenges for the detection of this signal. This paper investigates the extragalactic point source contamination and how accurately bright sources ({approx}>1 Jy) must be removed in order to detect 21 cm emission with upcoming radio telescopes such as the Murchison Widefield Array. We consider the residual contamination in 21 cm maps and power spectra due to position errors in the sky model for bright sources, as well as frequency-independent calibration errors. We find that a source position accuracy of 0.1 arcsec will suffice for detection of the H I power spectrum. For calibration errors, 0.05% accuracy in antenna gain amplitude is required in order to detect the cosmic signal. Both sources of subtraction error produce residuals that are localized to small angular scales, k{sub perpendicular} {approx}> 0.05 Mpc{sup -1}, in the two-dimensional power spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

Studies of uniformity of 50 μ m low-gain avalanche detectors at the Fermilab test beam

In this study, we report measurements of the uniformity of time resolution, signal amplitude, and charged particle detection efficiency across the sensor surface of low-gain avalanche detectors (LGAD). Comparisons of the performance of sensors with different doping concentrations and different active thicknesses are presented, as well as their temperature dependence and radiation tolerance up to 6 x 10 14 n/cm 2 . Results were obtained at the Fermilab test beam facility using 120 GeV proton beams, and a high precision pixel tracking detector. LGAD sensors manufactured by the Centro Nacional de Microelectrónica (CNM) and Hamamatsu Photonics (HPK) were studied. The uniformity of the sensor response in pulse height before irradiation was found to have a 2% spread. The signal detection efficiency and timing resolution in the sensitive areas before irradiation were found to be 100% and 30–40 ps, respectively. A “no-response” area between pads was measured to be about 130 μm for CNM and 170μm for HPK sensors. After a neutron fluence of 6 x 10 14 n/cm 2 the CNM sensor exhibits a large gain variation of up to a factor of 2.5 when comparing metalized and non-metalized sensor areas. An irradiated CNM sensor achieved a time resolution of 30 ps for the metalized area and 40 ps for the non-metalized area, while a HPK sensor irradiated to the same fluence achieved a 30 ps time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On infrasound generated by wind farms and its propagation in low-altitude tropospheric waveguides

Infrasound from a 60-turbine wind farm was found to propagate to distances up to 90 km under nighttime atmospheric conditions. Four infrasound sensor arrays were deployed in central New Mexico in February 2014; three of these arrays captured infrasound from a large wind farm. The arrays were in a linear configuration oriented southeast with 13, 54, 90, and 126 km radial distances and azimuths of 166°, 119°, 113°, and 111° from the 60 1.6 MW turbine Red Mesa Wind Farm, Laguna Pueblo, New Mexico, USA. Peaks at a fundamental frequency slightly below 0.9 Hz and its harmonics characterize the spectrum of the detected infrasound. The generation of this signal is linked to the interaction of the blades, flow gradients, and the supporting tower. The production of wind-farm sound, its propagation, and detection at long distances can be related to the characteristics of the atmospheric boundary layer. First, under stable conditions, mostly occurring at night, winds are highly stratified, which enhances the production of thickness sound and the modulation of other higher-frequency wind turbine sounds. Second, nocturnal atmospheric conditions can create low-altitude waveguides (with altitudes on the order of hundreds of meters) allowing long-distance propagation. Third, night and early morning hours are characterized by reduced background atmospheric noise that enhances signal detectability. This paper describes the characteristics of the infrasound from a quasi-continuous source with the potential for long-range propagation that could be used to monitor the lower part of the atmospheric boundary layer.

17 WIND ENERGY↗