Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Phase Locking of a 2.7 THz Quantum Cascade Laser to a Microwave Reference

We demonstrate the phase locking of a 2.7 THz metal-metal waveguide quantum cascade laser (QCL) to an external microwave signal. The reference is the 15th harmonic, generated by a semiconductor superlattice nonlinear device, of a signal at 182 GHz, which itself is generated by a multiplier chain (x 12) from a microwave synthesizer at approx. 15 GHz. Both laser and reference radiations are coupled into a bolometer mixer, resulting in a beat signal, which is fed into a phase-lock loop. The spectral analysis of the beat signal confirms that the QCL is phase locked. This result opens the possibility to extend heterodyne interferometers into the far-infrared range.

Khosropanah, P.↗

Input and Output Performance of M-MRAC in the Presence of Bounded Disturbances

This paper presents performance analysis of novel modified model reference adaptive control (M-MRAC) architecture in conjunction with different robust adaptive laws for the uncertain linear systems subject to unknown but bounded disturbances. It is shown that for any robust adaptive law the tracking error of the M-MRAC system can be arbitrarily decreased in transient and in the steady-state by increasing the adaptation rate, without generating high frequency oscillations in the control signal, which are unavoidable in conventional MRAC systems for large adaptation rates. Moreover, the generated adaptive control signal arbitrary closely tracks the ideal control signal when the error feedback gain is simultaneously increased with the adaptation rate, according to derived rule. The results are demonstrated via simulations.

Stepanyan, Vahram↗

Slew Timer For Symbol Display Generator

Slew-length timer generates delay and, at end of delay, signal indicating end of one of slews of electron beam in cathode-ray-tube display driven by symbol generator. End-of-slew signal constitutes "permission" for symbol generator to begin drawing next symbol segment.

Fisher, Paul A.↗

WE-A-17A-09: Exploiting Electromagnetic Technologies for Real-Time Seed Drop Position Validation in Permanent Implant Brachytherapy

Purpose: To report on preliminary results validating the performance of a specially designed LDR brachytherapy needle prototype possessing both electromagnetic (EM) tracking and seed drop detection abilities. Methods: An EM hollow needle prototype has been designed and constructed in collaboration with research partner Philips Healthcare. The needle possesses conventional 3D tracking capabilities, along with a novel seed drop detection mechanism exploiting local changes of electromagnetic properties generated by the passage of seeds in the needle's embedded sensor coils. These two capabilities are exploited by proprietary engineering and signal processing techniques to generate seed drop position estimates in real-time treatment delivery. The electromagnetic tracking system (EMTS) used for the experiment is the NDI Aurora Planar Field Generator. The experiment consisted of dropping a total of 35 seeds in a prismatic agarose phantom, and comparing the 3D seed drop positions of the EMTS to those obtained by an image analysis of subsequent micro-CT scans. Drop position error computations and statistical analysis were performed after a 3D registration of the two seed distributions. Results: Of the 35 seeds dropped in the phantom, 32 were properly detected by the needle prototype. Absolute drop position errors among the detected seeds ranged from 0.5 to 4.8 mm with mean and standard deviation values of 1.6 and 0.9 mm, respectively. Error measurements also include undesirable and uncontrollable effects such as seed motion upon deposition. The true accuracy performance of the needle prototype is therefore underestimated. Conclusion: This preliminary study demonstrates the potential benefits of EM technologies in detecting the passage of seeds in a hollow needle as a means of generating drop position estimates in real-time treatment delivery. Such tools could therefore represent a potentially interesting addition to existing brachytherapy protocols for rapid dosimetry validation. Equipments and fundings for this project were provided by Philips Medical.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonlinear optical response of metal-barrier-metal junctions

The optical response of metal-barrier-metal (MBM) junctions is discussed, with emphasis on the nonlinearity of response associated with reversal of polarity as optical intensity is increased. This nonlinear behavior can be used to measure correlation functions of optical pulses or to generate ultrashort electrical pulses. Expressions for the current flowing through the insulating barrier (junction), and for the rectification current, are given. Pulse signal and polarity of the electrical pulse evolves as the junction bias is varied about the null-signal bias. The apparatus used to obtain rectification pulse signals is described; the calculated evolution of the rectified pulse shape is found to correspond to that of pulse signals obtained experimentally. The generation of pulses six orders of magnitude smaller than a previously-obtained instrument-limited 1.6 nanosecond pulse has been observed.

Fan, B.↗

Methods, systems and apparatus for controlling operation of two alternating current (AC) machines

A system is provided for controlling two AC machines. The system comprises a DC input voltage source that provides a DC input voltage, a voltage boost command control module (VBCCM), a five-phase PWM inverter module coupled to the two AC machines, and a boost converter coupled to the inverter module and the DC input voltage source. The boost converter is designed to supply a new DC input voltage to the inverter module having a value that is greater than or equal to a value of the DC input voltage. The VBCCM generates a boost command signal (BCS) based on modulation indexes from the two AC machines. The BCS controls the boost converter such that the boost converter generates the new DC input voltage in response to the BCS. When the two AC machines require additional voltage that exceeds the DC input voltage required to meet a combined target mechanical power required by the two AC machines, the BCS controls the boost converter to drive the new DC input voltage generated by the boost converter to a value greater than the DC input voltage.

47 OTHER INSTRUMENTATION↗

Apparatus, system and method for highlighting activity-induced change in multi-pass synthetic aperture radar imagery

Described herein are various technologies relating to constructing a differenced change product (DCP) image. A plurality of synthetic aperture radar (SAR) images of a scene are generated based upon radar signals directed towards and reflected off of the scene, and a plurality of coherence change detection (CCD) images of the scene are generated based upon the SAR images. The CCD images are registered with one another, and their pixel values re-scaled according to a monotonic mapping function. The DCP image is generated based upon a computed pixel-wise difference between a pair of the re-scaled CCD images. The DCP image identifies locations in the scene where human activity-induced change is likely to have occurred between a pair of SAR passes of the scene.

42 ENGINEERING↗

WE-D-303-02: Applications of Volumetric Images Generated with a Respiratory Motion Model Based On An External Surrogate Signal

Purpose: Respiratory motion can vary significantly over the course of simulation and treatment. Our goal is to use volumetric images generated with a respiratory motion model to improve the definition of the internal target volume (ITV) and the estimate of delivered dose. Methods: Ten irregular patient breathing patterns spanning 35 seconds each were incorporated into a digital phantom. Ten images over the first five seconds of breathing were used to emulate a 4DCT scan, build the ITV, and generate a patient-specific respiratory motion model which correlated the measured trajectories of markers placed on the patients’ chests with the motion of the internal anatomy. This model was used to generate volumetric images over the subsequent thirty seconds of breathing. The increase in the ITV taking into account the full 35 seconds of breathing was assessed with ground-truth and model-generated images. For one patient, a treatment plan based on the initial ITV was created and the delivered dose was estimated using images from the first five seconds as well as ground-truth and model-generated images from the next 30 seconds. Results: The increase in the ITV ranged from 0.2 cc to 6.9 cc for the ten patients based on ground-truth information. The model predicted this increase in the ITV with an average error of 0.8 cc. The delivered dose to the tumor (D95) changed significantly from 57 Gy to 41 Gy when estimated using 5 seconds and 30 seconds, respectively. The model captured this effect, giving an estimated D95 of 44 Gy. Conclusion: A respiratory motion model generating volumetric images of the internal patient anatomy could be useful in estimating the increase in the ITV due to irregular breathing during simulation and in assessing delivered dose during treatment. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc. and Radiological Society of North America Research Scholar Grant #RSCH1206.

60 APPLIED LIFE SCIENCES↗

Wavelength modulation laser-induced fluorescence for plasma characterization

Laser-Induced Fluorescence (LIF) spectroscopy is an essential tool for probing ion and atom velocity distribution functions (VDFs) in complex plasmas. VDFs carry information about the kinetic properties of species that is critical for plasma characterization. Accurate interpretation of these functions is challenging due to factors such as multicomponent distributions, broadening effects, and background emissions. Our research investigates the use of Wavelength Modulation (WM) LIF to enhance the sensitivity of VDF measurements. Unlike standard Amplitude Modulation (AM) methods, WM–LIF measures the derivative of the LIF signal. This approach makes variations in VDF shape more pronounced. VDF measurements with WM–LIF were investigated with both numerical modeling and experimental measurements. The developed model enables the generation of both WM and AM signals, facilitating comparative analysis of fitting outcomes. Experiments were conducted in a weakly collisional argon plasma with magnetized electrons and non-magnetized ions. Measurements of the argon ion VDFs employed a narrow-band tunable diode laser, which scanned the 4p 4 D 7/2 –3d 4 F 9/2 transition centered at 664.553 nm in vacuum. A lock-in amplifier detected the second harmonic WM signal, which was generated by modulating the laser wavelength with an externally controlled piezo-driven mirror of the diode laser. Finally, our findings indicate that the WM–LIF signal is more sensitive to fitting parameters, allowing for better identification of VDF parameters such as the number of distribution components, their temperatures, and velocities. In addition, WM–LIF can serve as an independent method to verify AM measurements and is particularly beneficial in environments with substantial light noise or background emissions, such as those involving thermionic cathodes and reflective surfaces.

47 OTHER INSTRUMENTATION↗

Odd-bit symmetric QASK

Multiple-amplitude and phase-shift-keyed (MAPSK) signal set selection is influenced by factors such as average and/or peak signal-to-noise ratio for a given error probability, dynamic range of signal amplitudes, simplicity of generation and detection, and number of bit errors per adjacent symbol error. This paper compares two possible quadrature-amplitude-shift-keyed (QASK) signal sets for the case where the number of bits per symbol is odd (for the even-bit case, the square array is the only viable QASK choice). The symmetric QASK version out-performs the rectangular QASK set at a very modest implementation penalty. This permits symmetric QASK to be considered in future odd-bit system studies.

Smith, J. G.↗

Head related transfer function pseudo-stereophony

An apparatus for producing pseudo-stereophonic sound from a monaural signal is discussed. The apparatus includes a monaural source that has a speaker placed in an anechoic room and has a sound output generated by the monaural signal. The second, third, fourth, and fifth speakers are placed in the anechoic room symmetrically about a listener. The monaural signal from the source is processed to output processed signals to each of the second, third, fourth, and fifth speakers, each speaker producing a sound output corresponding to the received processed signal. A pair of microphones is placed in the ears of the listener for receiving the sound outputs of the first, second, third, fourth, and fifth speakers and producing two differentiated audio channels.

Begault, Durand R.↗

Membrane-associated signaling in human B-lymphoma lines

In B-non-Hodgkin lymphomas, Lyn and Cbp/PAG constitute the core of an oncogenic signalosome that captures the Phosphatidylinositol-3-kinase, the Spleen tyrosine kinase and the Signal transducer and activator of transcription-3 to generate pro-survival and proliferative signals. Lymphoma lines corresponding to follicular, mantle-cell and Burkitt-derived lymphomas display type-specific signalosome organizations that differentially activate PI3K, Syk and STAT3. In the follicular lymphoma line, PI3K, Syk and STAT3 were optimally activated upon association with the Lyn-Cbp/PAG signalosome, while in the Burkitt lymphoma-derived line, the association with Cbp/PAG and activation of PI3K were interfered with by the latent membrane proteins encoded by the Epstein-Barr virus. In the Jeko-1 mantle-cell line, a weak association of Syk with the Lyn-Cbp/PAG signalosome resulted in poor activation of Syk, but in those cells, as in the follicular and Burkitt-derived lines, efficient apoptosis induction by the Syk inhibitor R406 indicated that Syk is nonetheless an important prosurvival element and therefore a valuable therapeutic target. In all configurations described herein is the Lyn-Cbp/PAG signalosome independent of external signals and provides efficient means of activation for its associated lipid and protein kinases. In follicular and Burkitt-derived lines, Syk appears to be activated following binding to Cbp/PAG and no longer requires B-cell receptor-associated activation motifs for activation. Assessment of the different modalities of Lyn-Cbp/PAG signalosome organization could help in selecting the appropriate combination of kinase inhibitors to eliminate a particular type of lymphoma cells.

60 APPLIED LIFE SCIENCES↗

Microwave Transmitter With Multimode Output Section

Output-waveguide structure transports 400 kW of continuous-wave signal power at 34.5 GHz. Transmitter generates 400 kW of continuous-wave (CW) signal power. Main feature of conceptual design of this microwave transmitter is output section. Output waveguide structure includes mode converter, directional coupler, polarization monitor, and corrugated overmoded output section. Output directional pattern suitable for antenna illumination without flared feedhorn.

Hoppe, Daniel J.↗

Systems and methods for switched-inductor integrated voltage regulators

Power controller includes an output terminal having an output voltage, at least one clock generator to generate a plurality of clock signals and a plurality of hardware phases. Each hardware phase is coupled to the at least one clock generator and the output terminal and includes a comparator. Each hardware phase is configured to receive a corresponding one of the plurality of clock signals and a reference voltage, combine the corresponding clock signal and the reference voltage to produce a reference input, generate a feedback voltage based on the output voltage, compare the reference input and the feedback voltage using the comparator and provide a comparator output to the output terminal, whereby the comparator output determines a duty cycle of the power controller. An integrated circuit including the power controller is also provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Biomedical ultrasonoscope

The combination of a "C" mode scan electronics in a portable, battery powered biomedical ultrasonoscope having "A" and "M" mode scan electronics, the latter including a clock generator for generating clock pulses, a cathode ray tube having X, Y and Z axis inputs, a sweep generator connected between the clock generator and the X axis input of the cathode ray tube for generating a cathode ray sweep signal synchronized by the clock pulses, and a receiver adapted to be connected to the Z axis input of the cathode ray tube. The "C" mode scan electronics comprises a plurality of transducer elements arranged in a row and adapted to be positioned on the skin of the patient's body for converting a pulsed electrical signal to a pulsed ultrasonic signal, radiating the ultrasonic signal into the patient's body, picking up the echoes reflected from interfaces in the patient's body and converting the echoes to electrical signals; a plurality of transmitters, each transmitter being coupled to a respective transducer for transmitting a pulsed electrical signal thereto and for transmitting the converted electrical echo signals directly to the receiver, a sequencer connected between the clock generator and the plurality of transmitters and responsive to the clock pulses for firing the transmitters in cyclic order; and a staircase voltage generator connected between the clock generator and the Y axis input of the cathode ray tube for generating a staircase voltage having steps synchronized by the clock pulses.

Lee, R. D.↗

Implant for in-vivo parameter monitoring, processing and transmitting

The present invention relates to a completely implantable intracranial pressure monitor, which can couple to existing fluid shunting systems as well as other internal monitoring probes. The implant sensor produces an analog data signal which is then converted electronically to a digital pulse by generation of a spreading code signal and then transmitted to a location outside the patient by a radio-frequency transmitter to an external receiver. The implanted device can receive power from an internal source as well as an inductive external source. Remote control of the implant is also provided by a control receiver which passes commands from an external source to the implant system logic. Alarm parameters can be programmed into the device which are capable of producing an audible or visual alarm signal. The utility of the monitor can be greatly expanded by using multiple pressure sensors simultaneously or by combining sensors of various physiological types.

60 APPLIED LIFE SCIENCES↗

Digital noise generators using one-dimensional chaotic maps

This work shows how to improve the statistical distribution of signals produced by digital noise generators designed with one-dimensional (1-D) chaotic maps. It also shows that in a digital electronic design the piecewise linear chaotic maps (PWLCM) should be considered because they do not have stability islands in its chaotic behavior region, as it occurs in the case of the logistic map, which is commonly used to build noise generators. The design and implementation problems of the digital noise generators are analyzed and a solution is proposed. This solution relates the output of PWLCM, usually defined in the real numbers' domain, with a codebook of S elements, previously defined. The proposed solution scheme produces digital noise signals with a statistical distribution close to a uniform distribution. Finally, this work shows that it is possible to have control over the statistical distribution of the noise signal by selecting the control parameter of the PWLCM and using, as a design criterion, the bifurcation diagram.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theory of anomalous backscattering in second harmonic X-mode ECRH experiments

A quantitative model explaining generation of the anomalous backscattering signal in the second harmonic X-mode electron cyclotron resonance heating (ECRH) experiments at TEXTOR tokamak as a secondary nonlinear process which accompanies a primary low-threshold parametric decay instability (PDI) leading to excitation of two—upper hybrid (UH)—plasmons trapped in plasma is developed. The primary absolute PDI enhancing the UH wave fluctuations from the thermal noise level is supposed to be saturated due to a cascade of secondary low-threshold decays of the daughter UH wave leading to excitation of the secondary UH waves down-shifted in frequency and the ion Bernstein wave. A set of equations describing the cascade is derived and solved numerically. The results of numerical modelling are shown to be in agreement with the analytical estimations of the growth rate of the initial and secondary parametric decays and the saturation level. The generation of backscattering signal is explained by coupling of the daughter UH waves. The fine details of the frequency spectrum of the anomalously reflected extraordinary wave and the absolute value of the observed backscattering signal in the second harmonic X-mode ECRH experiments at TEXTOR are reproduced.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗