Search NASA⌕ Search

SEARCH · Search NASA

Results for “Software algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

The Viskores User's Guide, Release 1.1

High-performance computing relies on ever finer threading. Advances in processor technology include ever greater numbers of cores, hyperthreading, accelerators with integrated blocks of cores, and special vectorized instructions, all of which require more software parallelism to achieve peak performance. Traditional visualization solutions cannot support this extreme level of concurrency. Extreme scale systems require a new programming model and a fundamental change in how we design algorithms. To address these issues we created Viskores: the visualization toolkit for multi/many-core architectures. Viskores supports a number of algorithms and the ability to design further algorithms through a top-down design with an emphasis on extreme parallelism. Viskores also provides support for finding and building links across topologies, making it possible to perform operations that determine manifold surfaces, interpolate generated values, and find adjacencies. Although Viskores provides a simplified high-level interface for programming, its template-based code removes the overhead of abstraction.

97 MATHEMATICS AND COMPUTING↗

rapidMCR

rapidMCR is a user friendly software package that includes automatic preprocessing, analysis, and viewing of hyperspectral image data sets. Currently, this software package specifically preprocesses and analyzes hyperspectral fluorescence image data sets that have been created on Sandia hyperspectral imaging microscopes; however, this software can be modified to include spectroscopic image data sets from other (non-Sandia developed) instruments as well. This software relies on using prior information about the spectroscopic image data sets by conducting a rigorous characterization of the instrument. By characterizing the instrument for noise and artifacts, we can implement our algorithms to account for the effects specific to a particular instrument. This allows us to automate the data preprocessing while improving the analysis results.

Source record↗

Network Reduction Algorithm for Developing Distribution Feeders for Real-Time Simulators: Preprint

As advanced grid-support functions (AGF) become more widely used in grid-connected photovoltaic (PV) inverters, utilities are increasingly interested in their impacts when implemented in the field. These effects can be understood by modeling feeders in real-time systems and testing PV inverters using power hardware-in-the-loop (PHIL) techniques. This paper presents a novel feeder model reduction algorithm using a Monte Carlo method that enables large feeders to be solved and operated on real-time computing platforms. Two Hawaiian Electric feeder models in Synergi Electric's load flow software were converted to reduced order models in OpenDSS, and subsequently implemented in the OPAL-RT real-time digital testing platform. Smart PV inverters were added to the real-time model with AGF responses modeled after characterizing commercially available hardware inverters. Finally, hardware inverters were tested in conjunction with the real-time model using PHIL techniques so that the effects of AGFs on the choice feeders could be analyzed.

14 SOLAR ENERGY↗

Developing an Operational Testing Ground for Autonomous and Connected Vehicles

This paper provides a framework for developing a connected vehicle “sandbox” environment where connected vehicles equipped with Dedicated Short-Range Communication (DSRC) radios can interface with sensors that operate on a range of software architectures using open-source tools. In control system design, rapid prototyping for connected vehicle applications can be a challenge when the subsystems operate with different communication protocols, at different data rates, and with changing connectivity between subsystems. In this work, we showcase the use of open-source software tools, specifically the Robot Operating System (ROS), to facilitate connecting DSRC radios with embedded systems in both vehicle and infrastructure applications. Here, this integration helps in the rapid field testing of algorithms in an efficient manner in both hardware-in-the-loop applications as well as prototype deployments. Two examples are presented that demonstrate the use of this framework: 1) the use of DSRC systems for emergency responders in crash situations, and 2) using DSRC systems to reduce the fuel consumption of connected commercial trucks.

33 ADVANCED PROPULSION SYSTEMS↗

Development of Acoustic Model-Based Iterative Reconstruction Technique for Thick-Concrete Imaging

Ultrasound signals have been used extensively for non-destructive evaluation (NDE). However, typical reconstruction techniques, such as the synthetic aperture focusing technique (SAFT), are limited to quasi-homogenous thin media. New ultrasonic systems and reconstruction algorithms are in need for one-sided NDE of non-homogenous thick objects. An application example space is imaging of reinforced concrete structures for commercial nuclear power plants (NPPs). These structures provide important foundation, support, shielding, and containment functions. Identification and management of aging and degradation of concrete structures is fundamental to the proposed long-term operation of NPPs. Another example is geothermal and oil/gas production wells. These multi-layered structures are composed of steel, cement, and several types of soil and rocks. Ultrasound systems with greater penetration range and image quality will allow for better monitoring of the well's health and prediction of high-pressure hydraulic fracturing of the rock. These application challenges need to be addressed with an integrated imaging approach, where the application, hardware, and reconstruction software are highly integrated and optimized. Therefore, we are developing an ultrasonic system with Model-Based Iterative Reconstruction (MBIR) as the image reconstruction backbone. As the first implementation of MBIR for ultrasonic signals, this paper document the first implementation of the algorithm and show reconstruction results for synthetically generated data.

concrete NDE↗

Development of Acoustic Model-Based Iterative Reconstruction Technique for Thick-Concrete Imaging

Ultrasound signals have been used extensively for non-destructive evaluation (NDE). However, typical reconstruction techniques, such as the synthetic aperture focusing technique (SAFT), are limited to quasi-homogenous thin media. New ultrasonic systems and reconstruction algorithms are in need for one-sided NDE of non-homogenous thick objects. An application example space is imaging of reinforced concrete structures for commercial nuclear power plants (NPPs). These structures provide important foundation, support, shielding, and containment functions. Identification and management of aging and degradation of concrete structures is fundamental to the proposed long-term operation of NPPs. Another example is geothermal and oil/gas production wells. These multi-layered structures are composed of steel, cement, and several types of soil and rocks. Ultrasound systems with greater penetration range and image quality will allow for better monitoring of the well s health and prediction of high-pressure hydraulic fracturing of the rock. These application challenges need to be addressed with an integrated imaging approach, where the application, hardware, and reconstruction software are highly integrated and optimized. Therefore, we are developing an ultrasonic system with Model-Based Iterative Reconstruction (MBIR) as the image reconstruction backbone. As the first implementation of MBIR for ultrasonic signals, this paper document the first implementation of the algorithm and show reconstruction results for synthetically generated data.

Almansouri, Hani↗

Uniformly Ordered Binary Decision Algorithm for Benchmark Experiment Correlations in Whisper Validation

When performing a validation exercise for determining the upper subcritical limit of a nuclear criticality safety application, an analyst should select and perform a statistical analysis on a population of benchmark experiments that are neutronically similar to the application. The size of this population should be sufficiently large such that the statistical analysis has a high degree of confidence that the bias plus bias uncertainty (calculational margin) has been accurately quantified. A complication arises because many benchmark experiments share common components, leading to correlations in their measured effective multiplication factors. Correlations between benchmark experiments within the population reduces its predictive power. This motivates the need for methods that consider benchmark experiment correlations and ensure adequate statistical significance of results. The Whisper code is a statistical analysis pack- age that incorporates nuclear data sensitivity coefficients from MCNP to assess benchmark experiment similarity and then performs an extreme-value analysis to estimate the bias plus bias uncertainty. The original methodology in Whisper does not consider the effect of benchmark experiment correlations when making this estimation, and this summary proposes the uniformly ordered binary decision algorithm to address this shortcoming. The original methodology in Whisper computes similarity coefficients ck for an application compared to all benchmark experiments in its library and develops weighting factors for a selected population proportional to the ck values. The methodology can be interpreted as statistically emulating a validation exercise for a particular application where the weighting factors may be viewed as the likelihood that an analyst would include a particular benchmark experiment within the population. The effective sample size of the population is the expected or mean number of benchmark experiments in the population. The uniformly ordered binary decision algorithm identifies clusters of correlated benchmark experiments within the population and then computes adjusted weighting factors based on the magnitude of the correlation coefficients within the cluster to compute a reduced effective sample size accounting for the lower information content because of correlations. Benchmark experiments within the cluster are ordered randomly with equal probability and probabilistic decisions are made as to whether a benchmark. experiment within the cluster should treated as redundant with a previous one; if two redundant benchmark experiments are included, then the conservative worst case bias plus bias uncertainty is used and the pair is counted as a single benchmark experiment in the population. Results are provided for HEU solutions in a research version of the Whisper software using benchmark experiment correlations provided by DICE, the Database for the International Criticality Safety Benchmark Evaluation Project (ICSBEP). These show that there can be a significant increase in the bias plus bias uncertainty because the effective sample size is reduced, and therefore the algorithm, needing to meet sample size requirements, expands the benchmark experiment population by accepting less similar benchmark experiments that would have otherwise not been included.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HiSpatialCluster: A novel high‐performance software tool for clustering massive spatial points

Abstract In the era of big data, spatial clustering is a very important means for geo‐data analysis. When clustering big geo‐data such as social media check‐in data, geotagged photos, and taxi trajectory points, traditional spatial clustering algorithms are facing more challenges. On the one hand, existing spatial clustering tools cannot support the clustering of massive point sets; on the other hand, there is no perfect solution for self‐adaptive spatial clustering. In order to achieve clustering of millions or even billions of points adaptively, a new spatial clustering tool—HiSpatialCluster—was proposed, in which the CFSFDP (clustering by fast search and finding density peaks) idea to find cluster centers and the DBSCAN (density‐based spatial clustering of applications with noise) idea of density‐connect filtering for classification are introduced. The tool’s source codes and other resources have been released on Github, and experimental evaluation was performed through clustering massive taxi trajectory points and Flickr geotagged photos in Beijing, China. The spatial clustering results were compared with those through K‐means and DBSCAN as well. As a spatial clustering tool, HiSpatialCluster is expected to play a fundamental role in big geo‐data research. First, this tool enables clustering adaptively on massive point datasets with uneven spatial density distribution. Second, the density‐connect filter method is applied to generate homogeneous analysis units from geotagged data. Third, the tool is accelerated by both parallel CPU and GPU computing so that millions or even billions of points can be clustered efficiently.

Chen, Yiran↗

Incorporating Wind Energy in Power System Restoration Planning

Wind energy is rapidly growing. While wind brings us clean and inexpensive energy, its inherent variability and uncertainty present challenges for the power grid. In particular, employing wind energy for power system restoration is very challenging. A fast and reliable restoration plays a vital role to achieve the self-healing power grid. This paper develops a novel offline restoration planning tool for harnessing wind energy to enhance grid resilience. The Wind-for-Restoration problem is formulated as a stochastic mixed-integer linear programming problem with generated wind energy scenarios. The problem is then decomposed into two stages and solved with the integer Lshaped algorithm. Numerical experiments have been conducted through different case studies using the modified IEEE 57-bus system. The developed tool can provide the scheduled wind power at each restoration time. The impact of wind energy is investigated from the aspects of location and inertia capability, as well as wind penetration, fluctuation, and uncertainty. Moreover, a dynamic response validation tool is developed to validate the results of optimization problem in a dynamic simulation software. Finally, simulation results demonstrate that the optimal wind harnessing strategy can help improve system restoration process and enhance system resilience.

17 WIND ENERGY↗

SU-F-T-316: A Model to Deal with Dosimetric and Delivery Uncertainties in Radiotherapy Treatment Planning

Purpose The conventional way of dealing with uncertainties resulting from dose calculation or beam delivery in IMRT, is to do verification measurements for the plan in question. Here we present an alternative based on recommendations given in the AAPM 142 report and treatment specific parameters that model the uncertainties for the plan delivery. Methods Basis of the model is the assignment of uncertainty parameters to all segment fields or control point sequences of a plan. The given field shape is analyzed for complexity, dose rate, number of MU, field size related output as well as factors for in/out field position and penumbra regions. Together with depth related uncertainties, a 3D matrix is generated by a projection algorithm. Patient anatomy is included as uncertainty CT data set as well. Therefore, object density is classified in 4 categories close to water, lung, bone and gradient regions with additional uncertainties. The result is then exported as a DICOM dose file by the software tool (written in IDL, Exelis), having the given resolution and target point. Results Uncertainty matrixes for several patient cases have been calculated and compared side by side in the planning system. The result is not quite always intuitive but it clearly indicates high and low uncertainties related to OARs and target volumes as well as to measured gamma distributions.ConclusionThe imported uncertainty datasets may help the treatment planner to understand the complexity of the treatment plan. He then might decide to change the plan to produce a more suited uncertainty distribution, e.g. by changing the beam angles the high uncertainty spots can be influenced or try to use another treatment setup, resulting in a plan with lower uncertainties. A next step could be to include such a model into the optimization algorithm to add a new dose uncertainty constraint.

60 APPLIED LIFE SCIENCES↗

A Multiphase Validation of Atlas-Based Automatic and Semiautomatic Segmentation Strategies for Prostate MRI

Purpose: To perform a rigorous technological assessment and statistical validation of a software technology for anatomic delineations of the prostate on MRI datasets. Methods and Materials: A 3-phase validation strategy was used. Phase I consisted of anatomic atlas building using 100 prostate cancer MRI data sets to provide training data sets for the segmentation algorithms. In phase II, 2 experts contoured 15 new MRI prostate cancer cases using 3 approaches (manual, N points, and region of interest). In phase III, 5 new physicians with variable MRI prostate contouring experience segmented the same 15 phase II datasets using 3 approaches: manual, N points with no editing, and full autosegmentation with user editing allowed. Statistical analyses for time and accuracy (using Dice similarity coefficient) endpoints used traditional descriptive statistics, analysis of variance, analysis of covariance, and pooled Student t test. Results: In phase I, average (SD) total and per slice contouring time for the 2 physicians was 228 (75), 17 (3.5), 209 (65), and 15 seconds (3.9), respectively. In phase II, statistically significant differences in physician contouring time were observed based on physician, type of contouring, and case sequence. The N points strategy resulted in superior segmentation accuracy when initial autosegmented contours were compared with final contours. In phase III, statistically significant differences in contouring time were observed based on physician, type of contouring, and case sequence again. The average relative timesaving for N points and autosegmentation were 49% and 27%, respectively, compared with manual contouring. The N points and autosegmentation strategies resulted in average Dice values of 0.89 and 0.88, respectively. Pre- and postedited autosegmented contours demonstrated a higher average Dice similarity coefficient of 0.94. Conclusion: The software provided robust contours with minimal editing required. Observed time savings were seen for all physicians irrespective of experience level and baseline manual contouring speed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tokamak-independent software analysis suite for multi-spectral line-polarization MSE diagnostics

A tokamak-independent analysis suite has been developed to process data from Motional Stark Effect (mse) diagnostics. The software supports multi-spectral line-polarization mse diagnostics which simultaneously measure emission at the mse σ and π lines as well as at two "background" wavelengths that are displaced from the mse spectrum by a few nanometers. This analysis accurately estimates the amplitude of partially polarized background light at the σ and π wavelengths even in situations where the background light changes rapidly in time and space, a distinct improvement over traditional "time-interpolation" background estimation. The signal amplitude at many frequencies is computed using a numerical-beat algorithm which allows the retardance of the mse photo-elastic modulators (pem's) to be monitored during routine operation. It also allows the use of summed intensities at multiple frequencies in the calculation of polarization direction, which increases the effective signal strength and reduces sensitivity to pem retardance drift. The software allows the polarization angles to be corrected for calibration drift using a system that illuminates the mse diagnostic with polarized light at four known polarization angles within ten seconds of a plasma discharge. As a result, the software suite is modular, parallelized, and portable to other facilities.

97 MATHEMATICS AND COMPUTING↗

WE-G-BRD-07: Automated MR Image Standardization and Auto-Contouring Strategy for MRI-Based Adaptive Brachytherapy for Cervix Cancer

Purpose: MRI-based adaptive brachytherapy (ABT) is an emerging treatment modality for patients with gynecological tumors. However, MR image intensity non-uniformities (IINU) can vary from fraction to fraction, complicating image interpretation and auto-contouring accuracy. We demonstrate here an automated MR image standardization and auto-contouring strategy for MRI-based ABT of cervix cancer. Methods: MR image standardization consisted of: 1) IINU correction using the MNI N3 algorithm, 2) noise filtering using anisotropic diffusion, and 3) signal intensity normalization using the volumetric median. This post-processing chain was implemented as a series of custom Matlab and Java extensions in MIM (v6.4.5, MIM Software) and was applied to 3D T2 SPACE images of six patients undergoing MRI-based ABT at 3T. Coefficients of variation (CV=σ/µ) were calculated for both original and standardized images and compared using Mann-Whitney tests. Patient-specific cumulative MR atlases of bladder, rectum, and sigmoid contours were constructed throughout ABT, using original and standardized MR images from all previous ABT fractions. Auto-contouring was performed in MIM two ways: 1) best-match of one atlas image to the daily MR image, 2) multi-match of all previous fraction atlas images to the daily MR image. Dice’s Similarity Coefficients (DSCs) were calculated for auto-generated contours relative to reference contours for both original and standardized MR images and compared using Mann-Whitney tests. Results: Significant improvements in CV were detected following MR image standardization (p=0.0043), demonstrating an improvement in MR image uniformity. DSCs consistently increased for auto-contoured bladder, rectum, and sigmoid following MR image standardization, with the highest DSCs detected when the combination of MR image standardization and multi-match cumulative atlas-based auto-contouring was utilized. Conclusion: MR image standardization significantly improves MR image uniformity. The combination of MR image standardization and multi-match cumulative atlas-based auto-contouring produced the highest DSCs and is a promising strategy for MRI-based ABT for cervix cancer.

60 APPLIED LIFE SCIENCES↗

Interlaboratory comparison of secondary ion mass spectrometry analysis results from the 7th international technical nuclear forensics working group collaborative material exercise

A review and interlaboratory comparison of secondary ion mass spectrometry (SIMS) data obtained by laboratories participating in the International Technical Nuclear Forensics Working Group (ITWG) 7th Collaborative Material Exercise (CMX-7) has been conducted. The analyzed materials were two uranium compounds in powder form and two pieces of uranium metal. The instruments used in this comparison were a small-geometry (SG) SIMS, CAMECA IMS 7f from the Research Centre Rez, and a large-geometry (LG) SIMS, CAMECA IMS 1280 from Los Alamos National Laboratory. Despite the differences in instruments and analytical procedures, e.g., sample preparation, SIMS setups, and data post-processing, there was good agreement for the 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U ratios in the analyzed materials. The main difference was in the precision, which was, as expected, higher for the LG-SIMS. In addition, a comparison between the laboratories was also made for the image processing algorithms applied to raw data acquired in automated particle measurement (APM) mode. In conclusion, the result of this comparison has led to identification of best practices for setting up parameters of the APM software.

and nuclear chemistry↗

ProvSec: Open Cybersecurity System Provenance Analysis Benchmark Dataset with Labels

System provenance forensic analysis has been studied by a large body of research work. This area needs fine granularity data such as system calls along with event fields to track the dependencies of events. While prior work on security datasets has been proposed, we found a useful dataset of realistic attacks and details that are needed for high-quality provenance tracking is lacking. We created a new dataset of eleven vulnerable cases for system forensic analysis. It includes the full details of system calls including syscall parameters. Realistic attack scenarios with real software vulnerabilities and exploits are used. For each case, we created two sets of benign and adversary scenarios which are manually labeled for supervised machine-learning analysis. In addition, we present an algorithm to improve the data quality in the system provenance forensic analysis. We demonstrate the details of the dataset events and dependency analysis of our dataset cases.

97 MATHEMATICS AND COMPUTING↗

SU-F-BRD-13: Quantum Annealing Applied to IMRT Beamlet Intensity Optimization

Purpose: We report on the first application of quantum annealing (QA) to the process of beamlet intensity optimization for IMRT. QA is a new technology, which employs novel hardware and software techniques to address various discrete optimization problems in many fields. Methods: We apply the D-Wave Inc. proprietary hardware, which natively exploits quantum mechanical effects for improved optimization. The new QA algorithm, running on this hardware, is most similar to simulated annealing, but relies on natural processes to directly minimize the free energy of a system. A simple quantum system is slowly evolved into a classical system, representing the objective function. To apply QA to IMRT-type optimization, two prostate cases were considered. A reduced number of beamlets were employed, due to the current QA hardware limitation of ∼500 binary variables. The beamlet dose matrices were computed using CERR, and an objective function was defined based on typical clinical constraints, including dose-volume objectives. The objective function was discretized, and the QA method was compared to two standard optimization Methods: simulated annealing and Tabu search, run on a conventional computing cluster. Results: Based on several runs, the average final objective function value achieved by the QA was 16.9 for the first patient, compared with 10.0 for Tabu and 6.7 for the SA. For the second patient, the values were 70.7 for the QA, 120.0 for Tabu, and 22.9 for the SA. The QA algorithm required 27–38% of the time required by the other two methods. Conclusion: In terms of objective function value, the QA performance was similar to Tabu but less effective than the SA. However, its speed was 3–4 times faster than the other two methods. This initial experiment suggests that QA-based heuristics may offer significant speedup over conventional clinical optimization methods, as quantum annealing hardware scales to larger sizes.

07 ISOTOPE AND RADIATION SOURCES↗

Online 3D EPID-based dose verification: Proof of concept

Purpose: Delivery errors during radiotherapy may lead to medical harm and reduced life expectancy for patients. Such serious incidents can be avoided by performing dose verification online, i.e., while the patient is being irradiated, creating the possibility of halting the linac in case of a large overdosage or underdosage. The offline EPID-based 3D in vivo dosimetry system clinically employed at our institute is in principle suited for online treatment verification, provided the system is able to complete 3D dose reconstruction and verification within 420 ms, the present acquisition time of a single EPID frame. It is the aim of this study to show that our EPID-based dosimetry system can be made fast enough to achieve online 3D in vivo dose verification. Methods: The current dose verification system was sped up in two ways. First, a new software package was developed to perform all computations that are not dependent on portal image acquisition separately, thus removing the need for doing these calculations in real time. Second, the 3D dose reconstruction algorithm was sped up via a new, multithreaded implementation. Dose verification was implemented by comparing planned with reconstructed 3D dose distributions delivered to two regions in a patient: the target volume and the nontarget volume receiving at least 10 cGy. In both volumes, the mean dose is compared, while in the nontarget volume, the near-maximum dose (D2) is compared as well. The real-time dosimetry system was tested by irradiating an anthropomorphic phantom with three VMAT plans: a 6 MV head-and-neck treatment plan, a 10 MV rectum treatment plan, and a 10 MV prostate treatment plan. In all plans, two types of serious delivery errors were introduced. The functionality of automatically halting the linac was also implemented and tested. Results: The precomputation time per treatment was ∼180 s/treatment arc, depending on gantry angle resolution. The complete processing of a single portal frame, including dose verification, took 266 ± 11 ms on a dual octocore Intel Xeon E5-2630 CPU running at 2.40 GHz. The introduced delivery errors were detected after 5–10 s irradiation time. Conclusions: A prototype online 3D dose verification tool using portal imaging has been developed and successfully tested for two different kinds of gross delivery errors. Thus, online 3D dose verification has been technologically achieved.

60 APPLIED LIFE SCIENCES↗

SU-F-P-56: On a New Approach to Reconstruct the Patient Dose From Phantom Measurements

Purpose: The development of complex radiation treatment schemes emphasizes the need for advanced QA analysis methods to ensure patient safety. One such tool is the Delta4 DVH Anatomy software, where the patient dose is reconstructed from phantom measurements. Deviations in the measured dose are transferred to the patient anatomy and their clinical impact is evaluated in situ. Results from the original algorithm revealed weaknesses that may introduce artefacts in the reconstructed dose. These can lead to false negatives or obscure the effects of minor dose deviations from delivery failures. Here, we will present results from a new patient dose reconstruction algorithm. Methods: The main steps of the new algorithm are: (1) the dose delivered to a phantom is measured in a number of detector positions. (2) The measured dose is compared to an internally calculated dose distribution evaluated in said positions. The so-obtained dose difference is (3) used to calculate an energy fluence difference. This entity is (4) used as input to a patient dose correction calculation routine. Finally, the patient dose is reconstructed by adding said patient dose correction to the planned patient dose. The internal dose calculation in step (2) and (4) is based on the Pencil Beam algorithm. Results: The new patient dose reconstruction algorithm have been tested on a number of patients and the standard metrics dose deviation (DDev), distance-to-agreement (DTA) and Gamma index are improved when compared to the original algorithm. In a certain case the Gamma index (3%/3mm) increases from 72.9% to 96.6%. Conclusion: The patient dose reconstruction algorithm is improved. This leads to a reduction in non-physical artefacts in the reconstructed patient dose. As a consequence, the possibility to detect deviations in the dose that is delivered to the patient is improved. An increase in Gamma index for the PTV can be seen. The corresponding author is an employee of ScandiDos.

60 APPLIED LIFE SCIENCES↗