Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectral methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

A TEST OF THICK-TARGET NONUNIFORM IONIZATION AS AN EXPLANATION FOR BREAKS IN SOLAR FLARE HARD X-RAY SPECTRA

Solar nonthermal hard X-ray (HXR) flare spectra often cannot be fitted by a single power law, but rather require a downward break in the photon spectrum. A possible explanation for this spectral break is nonuniform ionization in the emission region. We have developed a computer code to calculate the photon spectrum from electrons with a power-law distribution injected into a thick target in which the ionization decreases linearly from 100% to zero. We use the bremsstrahlung cross section from Haug, which closely approximates the full relativistic Bethe-Heitler cross section, and compare photon spectra computed from this model with those obtained by Kontar et al., who used a step-function ionization model and the Kramers approximation to the cross section. We find that for HXR spectra from a target with nonuniform ionization, the difference (DELTAgamma) between the power-law indexes above and below the break has an upper limit between approx0.2 and 0.7 that depends on the power-law index delta of the injected electron distribution. A broken power-law spectrum with a higher value of DELTAgamma cannot result from nonuniform ionization alone. The model is applied to spectra obtained around the peak times of 20 flares observed by the Ramaty High-Energy Solar Spectroscopic Imager from 2002 to 2004 to determine whether thick-target nonuniform ionization can explain the measured spectral breaks. A Monte Carlo method is used to determine the uncertainties of the best-fit parameters, especially on DELTAgamma. We find that 15 of the 20 flare spectra require a downward spectral break and that at least six of these could not be explained by nonuniform ionization alone because they had values of DELTAgamma with less than a 2.5% probability of being consistent with the computed upper limits from the model. The remaining nine flare spectra, based on this criterion, are consistent with the nonuniform ionization model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-Image Registration for an Enhanced Vision System

An Enhanced Vision System (EVS) utilizing multi-sensor image fusion is currently under development at the NASA Langley Research Center. The EVS will provide enhanced images of the flight environment to assist pilots in poor visibility conditions. Multi-spectral images obtained from a short wave infrared (SWIR), a long wave infrared (LWIR), and a color visible band CCD camera, are enhanced and fused using the Retinex algorithm. The images from the different sensors do not have a uniform data structure: the three sensors not only operate at different wavelengths, but they also have different spatial resolutions, optical fields of view (FOV), and bore-sighting inaccuracies. Thus, in order to perform image fusion, the images must first be co-registered. Image registration is the task of aligning images taken at different times, from different sensors, or from different viewpoints, so that all corresponding points in the images match. In this paper, we present two methods for registering multiple multi-spectral images. The first method performs registration using sensor specifications to match the FOVs and resolutions directly through image resampling. In the second method, registration is obtained through geometric correction based on a spatial transformation defined by user selected control points and regression analysis.

Hines, Glenn↗

Nanodisplacement measurement using spectral shifts in a white-light interferometer

We report a novel experimental method to measure nanometer displacements using wavelength shifts of spectral peaks around spectral switch or singular phase points in the interference spectra due to temporal correlation in a Michelson interferometer illuminated by a broadband white-light source. Dramatic changes in the spectral characteristics are recorded as a function of path difference between the interfering beams around the spectral switch position. These are then compared with measurements far from it in order to demonstrate the higher sensitivities involved in the proposed method.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Flash Lamp Integrating Sphere Technique for Measuring the Dynamic Reflectance of Shocked Materials

Accurate reflectance (R) measurements of metals undergoing shock wave compression can benefit high pressure research in several ways. For example, pressure dependent reflectance measurements can be used to deduce electronic band structure, and discrete changes with pressure or temperature may indicate the occurrence of a phase boundary. Additionally, knowledge of the wavelength dependent emissivity (1 -R, for opaque samples) of the metal surface is essential for accurate pyrometric temperature measurement because the radiance is a function of both the temperature and emissivity. We have developed a method for measuring dynamic reflectance in the visible and near IR spectral regions with nanosecond response time and less than 1.5% uncertainty. The method utilizes an integrating sphere fitted with a xenon flash-lamp illumination source. Because of the integrating sphere, the measurements are insensitive to changes in surface curvature or tilt. The in-situ high brightness of the flash-lamp exceeds the sample’s thermal radiance and also enables the use of solid state detectors for recording the reflectance signals with minimal noise. Using the method, we have examined the dynamic reflectance of gallium and tin subjected to shock compression from high explosives. The results suggest significant reflectance changes across phase boundaries for both metals. We have also used the method to determine the spectral emissivity of shock compressed tin at the interface between tin and a LiF window. The results were used to perform emissivity corrections to previous pyrometry data and obtain shock temperatures of the tin/LiF interface with uncertainties of less than 2%.

Stevens, Gerald↗

The eROSITA Final Equatorial-Depth Survey (eFEDS): The AGN catalog and its X-ray spectral properties

The eROSITA Final Equatorial Depth Survey (eFEDS), observed with eROSITA ahead of its planned 4-yr all-sky survey, is the largest contiguous-field X-ray survey at present. It yielded a large sample of X-ray sources with very rich multiband photometric and spectroscopic coverage. We present here the eFEDS active galactic nuclei (AGN) catalog and the eROSITA X-ray spectral properties of the eFEDS sources. Using a Bayesian method, we performed a systematic X-ray spectral analysis for all the eFEDS sources. We adopted multiple spectral models, including single-component power-law or hot-plasma models and double-component models of a power law plus soft excess. We investigated the capacity of eROSITA X-ray spectra for constraining AGN spectral shapes through a detailed analysis of the posterior parameter probability distribution functions. Hierarchical Bayesian modeling was used to recover the spectral parameter distribution of the sample. The source fluxes and luminosities were measured from the posterior of the spectral fitting. The eFEDS AGN catalog (22 079 sources) comprises ~80% of the eFEDS point sources. Despite a large number of faint sources, our spectral fitting provides reasonable measurements of spectral shapes and intrinsic luminosities for a majority of the sources. Because of sample selection bias, this AGN catalog is dominated by X-ray unobscured sources, with an obscured (logN H > 21.5) fraction of 8%; the power-law emission of the hot corona is also relatively soft, with a typical slope of 2.0. For type-I AGN, the X-ray emission is well correlated with the UV emission with the usual anticorrelation between the X-ray to UV spectral slope α OX and the UV luminosity. The X-ray spectral properties measured with various models are presented for all the eFEDS sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Recovering Aerodynamic Side Loads on Rocket Nozzles using Quasi-Static Strain-Gage Measurements

During over-expanded operation of rocket nozzles, which is defined to be when the exit pressure is greater than internal pressure over some part of the nozzle, the nozzle will experience a transverse forcing function due to the pressure differential across the nozzle wall. Over-expansion occurs during the nozzle start-up and shutdown transient, even in high-altitude engines, because most test facilities cannot completely reproduce the near-vacuum pressures at those altitudes. During this transient, the pressure differential moves axially down the nozzle as it becomes pressurized, but this differential is never perfectly symmetric circumferentially. The character of the forcing function is highly complex and defined by a series of restricted and free shock separations. The subject of this paper is the determination of the magnitude of this loading during sub-scale testing via measurement of the structural dynamic response of the nozzle and its support structure. An initial attempt at back-calculating this load using the inverse of the transfer function was performed, but this attempt was shown to be highly susceptible to numerical error. The final method chosen was to use statically calibrated strain data and to filter out the system fundamental frequency such that the measured response yields close to the correct dynamic loading function. This method was shown to capture 93% of the pressure spectral energy using controlled load shaker testing. This method is one of the only practical ways for the inverse determination of the forcing function for non-stationary excitations, and, to the authors' knowledge, has not been described in the literature to date.

Brown, Andrew↗

Ground-Based Correction of Remote-Sensing Spectral Imagery

Software has been developed for an improved method of correcting for the atmospheric optical effects (primarily, effects of aerosols and water vapor) in spectral images of the surface of the Earth acquired by airborne and spaceborne remote-sensing instruments. In this method, the variables needed for the corrections are extracted from the readings of a radiometer located on the ground in the vicinity of the scene of interest. The software includes algorithms that analyze measurement data acquired from a shadow-band radiometer. These algorithms are based on a prior radiation transport software model, called MODTRAN, that has been developed through several versions up to what are now known as MODTRAN4 and MODTRAN5 . These components have been integrated with a user-friendly Interactive Data Language (IDL) front end and an advanced version of MODTRAN4. Software tools for handling general data formats, performing a Langley-type calibration, and generating an output file of retrieved atmospheric parameters for use in another atmospheric-correction computer program known as FLAASH have also been incorporated into the present soft-ware. Concomitantly with the soft-ware described thus far, there has been developed a version of FLAASH that utilizes the retrieved atmospheric parameters to process spectral image data.

Alder-Golden, Steven M.↗

Effective methylation of phosphonic acids related to chemical warfare agents mediated by trimethyloxonium tetrafluoroborate for their qualitative detection and identification by gas chromatography-mass spectrometry

The effective methylation of phosphonic acids related to chemical warfare agents (CWAs) employing trimethyloxonium tetrafluoroborate (TMO·BF 4 ) for their qualitative detection and identification by gas chromatography-mass spectrometry (GC-MS) is presented. The methylation occurs in rapid fashion (1 h) and can be conveniently carried out at ambient temperature, thus providing a safer alternative to the universally employed diazomethane-based methylation protocols. Optimization of the methylation parameters led us to conclude that methylene chloride was the ideal solvent to carry out the derivatization, and that even though methylated products can be observed surfacing after only 1 h, additional time was not found to be detrimental but beneficial to the process particularly when dealing with analytes at low concentrations (~10 μg mL -1 ). Due to its insolubility in methylene chloride, TMO·BF 4 conveniently settles to the bottom during the reaction and does not produce additional interfering by-products that may further complicate the GC-MS analysis. We demonstrated the method to successfully methylate a variety of Schedule 2 phosphonic acids, including their half esters, resulting in derivatives that were readily detected and identified using the instrument's spectral library. Most importantly, the method was shown to simultaneously methylate a mixture of the organophosphorus-based nerve agent hydrolysis products: pinacolyl methylphosphonate (PMPA), cyclohexyl methylphosphonate (CyMPA) and ethyl methylphosphonate (EMPA) (at a 10 μg mL - 1 concentration each) in a fatty acid ester-rich organic matrix (OPCW-PT-O 3 ) featured in the 38th Organisation for the Prohibition of Chemical Weapons (OPCW) Proficiency Test. Additionally, the protocol was found to effectively methylate N,N-diethylamino ethanesulfonic acid and N,N-diisopropylamino ethanesulfonic acid that are products arising from the oxidative degradation of the V-series agents VR and VX respectively. This work described herein represents the first report on the use of TMO·BF 4 as a viable, stable and safe agent for the methylation of phosphonic acids and their half esters and within the context of an OPCW Proficiency Test sample analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

System-independent characterization of materials using dual-energy computed tomography

In this study, we present a new decomposition approach for dual-energy computed tomography (DECT) called SIRZ that provides precise and accurate material description, independent of the scanner, over diagnostic energy ranges (30 to 200 keV). System independence is achieved by explicitly including a scanner-specific spectral description in the decomposition method, and a new X-ray-relevant feature space. The feature space consists of electron density, ρ e , and a new effective atomic number, Z e , which is based on published X-ray cross sections. Reference materials are used in conjunction with the system spectral response so that additional beam-hardening correction is not necessary. The technique is tested against other methods on DECT data of known specimens scanned by diverse spectra and systems. Uncertainties in accuracy and precision are less than 3% and 2% respectively for the (ρ e , Z e ) results compared to prior methods that are inaccurate and imprecise (over 9%).

42 ENGINEERING↗

Studies of the Raman Spectra of Cyclic and Acyclic Molecules: Combination and Prediction Spectrum Methods

A combination of Raman spectroscopy and density functional methods was employed to investigate the spectral features of selected molecules: furfural, 5-hydroxymethyl furfural (HMF), methanol, acetone, acetic acid, and levulinic acid. The computed spectra and measured spectra are in excellent agreement, consistent with previous studies. Using the combination and prediction spectrum method (CPSM), we were able to predict the important spectral features of two platform chemicals, HMF and levulinic acid.The results have shown that CPSM is a useful alternative method for predicting vibrational spectra of complex molecules in the biomass transformation process.

Environmental Molecular Sciences Laboratory↗

Determination of alloy content from plume spectral measurements

The mathematical derivation for a method to determine the identities and amounts of alloys present in a flame where numerous alloys may be present is described. This method is applicable if the total number of elemental species from all alloys that may be in the flame is greater than or equal to the total number of alloys. Arranging the atomic spectral line emission equations for the elemental species as a series of simultaneous equations enables solution for identity and amount of the alloy present in the flame. This technique is intended for identification and quantification of alloy content in the plume of a rocket engine. Spectroscopic measurements reveal the atomic species entrained in the plume. Identification of eroding alloys may lead to the identification of the eroding component.

Madzsar, George C.↗

Determination of alloy content from plume spectral measurements

The mathematical derivation for a method to determine the identities and amounts of alloys present in a flame where numerous alloys may be present is described. This method is applicable if the total number of elemental species from all alloys that may be in the flame is greater than or equal to the total number of alloys. Arranging the atomic spectral line emission equations for the elemental species as a series of simultaneous equations enables solution for identify and amount of the alloy present in the flame. This technique is intended for identification and quantification of alloy content in the plume of a rocket engine. Spectroscopic measurements reveal the atomic species entrained in the plume. Identification of eroding alloys may lead to the identification of the eroding component.

Madzsar, George C.↗

Non-invasive material discrimination using spectral x-ray radiography

Current radiographic methods are limited in their ability to determine the presence of nuclear materials in containers or composite objects. A central problem is the inability to distinguish the attenuation pattern of high-density metals from those with a greater thickness of a less dense material. Here, we show that spectrally sensitive detectors can be used to discriminate plutonium from multiple layers of other materials using a single-view radiograph. An inverse algorithm with adaptive regularization is used. The algorithm can determine the presence of plutonium in simulated radiographs with a mass resolution per unit area of at least 0.07 g cm{sup −2}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An experimental topographic amplification study at Los Alamos National Laboratory using ambient vibrations

An experimental study aimed at investigating potential topographic amplification of seismic waves was conducted on a 50-m-tall and 185-m-wide soft-rock ridge located at Los Alamos National Laboratory near Los Alamos, New Mexico. Ten portable broadband seismograph stations were placed in arrays across the ridge and left to record ambient vibration data for ~9 hours. Clear evidence of topographic amplification was observed by comparing spectral ratios calculated from ambient noise recordings at the toe, slope, and crest of the instrumented ridge. The inferred resonance frequency of the ridge obtained from the experimental recordings was found to agree well with several simple estimates of the theoretical resonance frequency based on its geometry and stiffness. Results support the feasibility of quantifying the frequency range of topographic amplification solely using ambient vibrations, rather than strong or weak ground motions. Additionally, comparisons have been made between a number of widely used experimental methods for quantifying topographic effects, such as the standard spectral ratio, median reference method, and horizontal-to-vertical spectral ratio. As a result, differences in the amplification and frequency range of topographic effects indicated by these methods highlight the importance of choosing a reference condition that is appropriate for the site-specific conditions and goals associated with an experimental topographic amplification study.

58 GEOSCIENCES↗

ClassNMSW- a real-time classification approach for non-recycled municipal solid waste using hyperspectral imaging

Real-time classification of non-recycled municipal solid waste (NMSW) is essential for efficient valorization. This study introduces ClassNMSW, a comprehensive framework for classifying 22 NMSW subclasses under industrial constraints by using hyperspectral imaging (HSI). A primary innovation of this work is the development of a variance-controlled spectral extraction algorithm. Unlike traditional methods that rely on simple averaging, this approach systematically investigates the extent of pixel extraction to minimize the loss of critical chemical information while maximizing data reduction thus ensuring high spectral fidelity with low computational cost. The approach developed in this work integrates automated, computer-vision-based background removal, eliminating the need for the manual thresholding common in current literature. To resolve ambiguities among chemically similar subclasses, a tiered classification and multi-camera fusion strategy (NIR17 and NIR22) is implemented. Results demonstrate that ClassNMSW achieves an object-wise weighted accuracy of 98.70% for single-sensor configurations and 100% under sensor fusion. A novel rolling-window strategy satisfies desired end-to-end latency of <2 s, satisfying the strict deterministic requirements of high-speed industrial sorting environments. The ClassNMSW framework provides a scalable foundation for advancing circularity and resource recovery in large-scale waste valorization operations.

99 - GENERAL AND MISCELLANEOUS↗

First-principles electron-phonon interactions and polarons in the parent cuprate La 2 CuO 4

Understanding electronic interactions in high-temperature superconductors is an outstanding challenge. In the widely studied cuprate materials, experimental evidence points to strong electron-phonon ( e -ph) coupling and broad photoemission spectra. Yet, the microscopic origin of this behavior is not fully understood. Here, we study e -ph interactions and polarons in a prototypical parent (undoped) cuprate, La 2 CuO 4 (LCO), by means of first-principles calculations. Leveraging parameter-free Hubbard-corrected density functional theory, we obtain a ground state with the band gap and Cu magnetic moment in nearly exact agreement with experiments. This enables a quantitative characterization of e -ph interactions. Our calculations reveal two classes of longitudinal optical (LO) phonons with strong e -ph coupling to hole states. These modes consist of bond stretching and bond bending in the Cu-O plane as well as vibrations of apical O atoms. The hole spectral functions, obtained with a cumulant method that can capture strong e -ph coupling, exhibit broad quasiparticle peaks with a small spectral weight ( Z ≈ 0.25 ) and pronounced LO-phonon sidebands characteristic of polaron effects. Our calculations predict features observed in photoemission spectra, including a 40-meV peak in the e -ph coupling distribution function not explained by existing models. These results show that the universal strong e -ph coupling found experimentally in doped lanthanum cuprates is also present in the parent compound, and elucidate its microscopic origin. Published by the American Physical Society 2025

Chang, Benjamin K. (ORCID:0000000313049324)↗

Retrievals of surface reflectances from AVIRIS data

A method for retrieving surface reflectances from spectral data collected by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) is being developed. In this method, the integrated water vapor amount on a pixel by pixel basis is derived from the 0.94- and 1.14-micron water vapor features. The water vapor, carbon dioxide (CO2), oxygen (O2) and methane (CH4) transmission spectrum in the 0.4-2.5 micron region is calculated. The derived water vapor value and the solar and observational geometry are used in the calculation. The AVIRIS spectrum is ratioed against the transmission spectrum to obtain the surface reflectance spectrum. Major mineral absorption features near 2.2 microns in retrieved reflectance spectra can be identified. Different vegetation absorption characteristics are observed. At present, the method is most useful for deriving surface reflectances from AVIRIS data measured on clear days with high visibilities.

Gao, Bo-Cai↗

A Test of Thick-Target Nonuniform Ionization as an Explanation for Breaks in Solar Flare Hard X-Ray Spectra

Solar nonthermal hard X-ray (HXR) flare spectra often cannot be fitted by a single power law, but rather require a downward break in the photon spectrum. A possible explanation for this spectral break is nonuniform ionization in the emission region. We have developed a computer code to calculate the photon spectrum from electrons with a power-law distribution injected into a thick-target in which the ionization decreases linearly from 100% to zero. We use the bremsstrahlung cross-section from Haug (1997), which closely approximates the full relativistic Bethe-Heitler cross-section, and compare photon spectra computed from this model with those obtained by Kontar, Brown and McArthur (2002), who used a step-function ionization model and the Kramers approximation to the cross-section. We find that for HXR spectra from a target with nonuniform ionization, the difference (Delta-gamma) between the power-law indexes above and below the break has an upper limit between approx.0.2 and 0.7 that depends on the power-law index delta of the injected electron distribution. A broken power-law spectrum with a. higher value of Delta-gamma cannot result from nonuniform ionization alone. The model is applied to spectra obtained around the peak times of 20 flares observed by the Ramaty High Energy Solar Spectroscopic Imager (RHESSI from 2002 to 2004 to determine whether thick-target nonuniform ionization can explain the measured spectral breaks. A Monte Carlo method is used to determine the uncertainties of the best-fit parameters, especially on Delta-gamma. We find that 15 of the 20 flare spectra require a downward spectral break and that at least 6 of these could not be explained by nonuniform ionization alone because they had values of Delta-gamma with less than a 2.5% probability of being consistent with the computed upper limits from the model. The remaining 9 flare spectra, based on this criterion, are consistent with the nonuniform ionization model.

Holman, gordon↗