Search NASA⌕ Search

SEARCH · Search NASA

Results for “System Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Effects of bentonite heating on U(VI) adsorption

Engineered barrier systems designed to isolate high-level radioactive waste utilize bentonite, a montmorillonite rich material, to restrict contaminant transport due to its low hydraulic conductivity and high adsorption capacity. High temperatures (100–200 °C) near waste canisters resulting from radioactive decay may alter the clay's ability to adsorb contaminants. In this study, we examine U(VI) adsorption onto two different bentonite samples subjected to (1) 18 years of in situ heating during an underground experiment and (2) short-term (7-week), high temperature (300 °C) heating in the laboratory. Results show that U(VI) adsorption was lower for field-heated bentonite located closest to the heater, which experienced temperatures of approximately 95 °C, compared to a control sample, which experienced temperatures of approximately 20 °C, over a range of aqueous chemical conditions. On average, K d values for U(VI) adsorption were 31% lower for 95 °C heated samples. By contrast, U(VI) adsorption onto intermediate-heated bentonite (50 °C) was indistinguishable from the adsorption onto the cold-zone (20 °C) sample. U(VI) adsorption onto lab-heated bentonite was also lower than onto control bentonite over the pH range 4.5–8.0, with an average decrease in K d values of 50% after heating. Lower U(VI) adsorption to field-heated bentonite persisted after bentonite was purified to isolate the clay fraction. This allows us to rule out changes in pore-water chemistry or accessory mineral composition as causes of the lower adsorption. No evidence of montmorillonite illitization was observed in the heated samples. While some of the lower U(VI) adsorption in the lab-heated bentonite can be explained by changes in aqueous U(VI) speciation, we propose that lower U(VI) adsorption to field-heated bentonite may be primarily due to changes in the montmorillonite edge structure. The observed changes in U(VI) adsorption to bentonite after heating have implications for U(VI) diffusive transport through engineered barriers and must be considered when designing radioactive waste disposal repositories.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental and analytical study of the hydrodynamic and single and two-phase convective heat transfer performance of flexible PDMS microchannels with micropillar arrays

Various copper and silicon based thermal management systems are used in the cooling of electronics. However, the rigid nature of these materials along with their high thermal and electrical conductivity pose a difficulty in developing direct contact embedded flexible cooling systems that can offer robust cooling performance. The low density, thermal stability, chemical inertness, and electrical insulation of Polydimethylsiloxane (PDMS) make it an ideal material to develop lightweight direct contact thermal management systems for electronics. Its ease of fabrication with tunable flexibility provides the opportunity to go beyond traditional electronics and develop advanced active and passive thermal management systems for a wide–range of applications in foldable and wearable electronics, liquid cooling garments, microgravity, and electric motors. In this study, a flexible PDMS based microchannel with micropillar arrays, which enhance the thermal performance of the device through capillary-assisted flow, has been developed. The hydrodynamic and convection heat transfer performance of three PDMS wick pillar geometries, ranging from a porosity of 0.8–0.91, are investigated and compared under single-phase and two-phase conditions. Dielectric coolant FC-3283 is employed and permeability measurements are made for mass fluxes ranging from 53 kg/m 2 s to 369 kg/m 2 s. Given its conformability, the device demonstrates a deviation from Darcy’s Law, within the laminar regime, with an increasing permeability with mass flux at the rate of ~0.5–0.8 Darcy/(kg/m 2 s). A semi-analytical model has been developed and reported to quantify the conformability of the device. The heat transfer performance is experimentally evaluated using the same dielectric fluid for mass flux ranging from 105 kg/m 2 s to 420 kg/m 2 s with heat fluxes ranging from 1.5 W/cm 2 to 16 W/cm 2 . Heat transfer coefficients of up to 7000 W/m 2 K are observed, which are comparable to copper and silicon microchannels. The effect of porosity on the single phase thermal performance has been evaluated against the pumping power to provide a basis for thermal management system design. Finally, high-speed imaging is performed to study the two-phase flow characteristics to provide insight into the vapor formation and removal.

42 ENGINEERING↗

Multiscale modeling of microwave-heated multiphase systems

Modeling of microwave heating of multiphase systems requires resolving the electromagnetic field from the single particle to the entire cavity. We introduce a multiscale methodology for computationally affordable simulations of microwave heating of multiphase systems consisting of one phase dispersed in a continuum phase. The methodology homogenizes the original multiphase system, by taking advantage of the large separation of length scales, to calculate the effective permittivity, effective thermal conductivity, and volumetric power absorbed in each phase. The methodology is rigorously assessed against particle-resolved detailed numerical simulations of model systems. We demonstrate a significant reduction in computational cost while retaining the accuracy of detailed simulations. Lastly, the present methodology enables high throughput exploration of novel multiphase system designs utilizing microwave heating.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Long-term strength retrogression of silica-enriched oil well cement: A comprehensive multi-approach analysis

The strength retrogression of a Class G cement enriched by adding 60–80% silica cured under the condition of 200 °C and 50 MPa were investigated by multiple different analysis methods. Short-term strength analysis suggests sonic strength testing is a poor indicator of real mechanical strength at such curing condition. Long-term testing up to 142 d shows all designed systems experiences dramatic deterioration in physical and mechanical properties, such as compressive strength, Young's modulus, water permeability and gas permeability. Further testing was conducted using X-ray diffraction, thermal gravimetric analysis, mercury intrusion and scanning electron microscope. The study reveals that the set cement experiences significant microstructure coarsening with increasing curing time, especially after 30 d curing. The strength retrogression and microstructure coarsening seem to be accompanied with the continued consumption of silica, and are likely caused by the gradual conversion of semi-crystalline C-S-H into crystalline tobermorite and xonolite over the long-term curing.

36 MATERIALS SCIENCE↗

Data-driven simultaneous process optimization and adsorbent selection for vacuum pressure swing adsorption

Technologies for post-combustion carbon capture are essential for the reduction of greenhouse gas emissions to the atmosphere. However, they are still associated with high costs and energy consumption. Intensified processes for carbon capture have the potential to overcome these challenges due to their higher efficiency, lower capital cost, and increased operational flexibility. Here, this work investigates simultaneous optimization of process conditions and adsorbent selection for a modular Vacuum Pressure-Swing Adsorption system designed for CO 2 capture. Both surrogate-based Nonlinear Programming and Mixed-Integer Nonlinear Programming approaches are applied and compared in terms of computational efficiency and solution accuracy. Moreover, process performance results are examined by applying several data analytics techniques to gain insights into the material-process correlations. Data-driven classifiers and neural networks can accurately predict whether a material is likely to satisfy purity, recovery, and energy constraints when operated at optimal process conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermally driven electrokinetic energy conversion with liquid water microjets

One goal of current energy research is to design systems and devices that can efficiently exploit waste heat and utilize solar or geothermal heat energy for electrical power generation. We demonstrate a novel technique exploiting water's large coefficient of thermal expansion, wherein modest thermal gradients produce the requisite high pressure for driving fast-flowing liquid water microjets, which can effect the direct conversion of the kinetic energy into electricity and gaseous hydrogen. Waste heat in thermoelectric generating plants and combustion engines, as well as solar and geothermal energy could be used to drive these systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimization-based modeling and economic comparison of membrane distillation configurations for application in shale gas produced water treatment

Membrane distillation (MD) is an emerging membrane technology with great potential for treatment of hypersaline wastewater generated by unconventional (shale) oil and gas reservoirs. However, the low energy efficiency of this technology makes the operating cost of MD systems relatively high, especially in the absence of waste heat. There are several MD configurations with inherent advantages and disadvantages and varying performance. As such, there is a need for thermo-economic optimization of MD systems in a systematic manner to assess their economic performance. Here we present an optimization framework to model and compare the performance of six MD configurations (DCMD, AGMD, PGMD, CGMD, SGMD, and VMD) in continuous recirculation mode for treatment of hypersaline wastewater. The optimization results show that AGMD with small gap size operated at low stream Reynolds number outperforms all other configurations with treatment cost of 4.57 US $/m 3 of feed. However, restricting the system design to more practically relevant operating conditions, such as higher Reynolds number and larger gap size, diminishes the cost superiority of AGMD over other configurations. We also observed that treatment cost using PGMD configuration approaches those of CGMD and DCMD, particularly when modules with small gaps are used.

42 ENGINEERING↗

Revealing Occupancy Patterns in an Office Building through the Use of Occupancy Sensor Data

Energy simulation programs like DOE-2 and EnergyPlus are tools that have been proven to aid with energy calculations to predict energy use in buildings. Some inputs to energy simulation models are relatively easy to find, including building size, orientation, construction materials, and HVAC system size and type. Others vary with time (e.g. weather and occupancy) and some can be a challenge to estimate in order to create an accurate simulation. In this paper, the analysis of occupancy sensor data for a large commercial, multi-tenant office building is presented. It details occupancy diversity factors for private offices and summarizes the same for open offices, hallways, conference rooms, break rooms, and restrooms in order to better inform energy simulation parameters. Long-term data were collected allowing results to be presented to show variations of occupancy diversity factors in private offices for time of day, day of the week, holidays, and month of the year. The diversity factors presented differ as much as 46% from those currently published in ASHRAE 90.1 2004 energy cost method guidelines, a document referenced by energy modelers regarding occupancy diversity factors for simulations. This may result in misleading simulation results and may introduce inefficiencies in the final equipment and systems design.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Techno-economic feasibility of borehole thermal energy storage system connected to geothermal heat pumps for seasonal heating load of two buildings in Fairbanks, Alaska

Borehole thermal energy storage (BTES) is an effective solution for managing imbalanced heating and cooling loads in cold regions. This study evaluated the long-term feasibility of a BTES system in the Fairbanks area, Alaska, through building energy modeling, resource characterization, and numerical modeling. The system was designed to store waste heat from a nearby coal power plant during summer and provide thermal energy during winter to geothermal heat pumps supplying heating loads in two buildings. Heating load profiles were modeled for the buildings using EnergyPlus, and the results indicated the annual heating load was 5.6 times greater than the cooling load. 40 borehole heat exchangers were pre-designed approximately 100 m away from the two buildings in terms of land availability and regulatorily optimized depth. The 20-year performance of the designed BTES system under two operational scenarios—one with a 5-year preheating period and one without—was numerically modeled using subsurface temperature and properties characterized through the literature review and thermal response tests. Both scenarios demonstrated that the BTES has the capacity to fully cover the heating loads in the two buildings throughout the 20-year lifetime. Production temperatures at central wells were 33 % higher on average than at outer wells in both scenarios. The 5-year preheating period increased subsurface and extraction temperatures, and correspondingly annual average and total thermal energy production was higher for 8 years than in the scenario without the preheating period. These results highlight the long-term reliability and sustainability of the BTES system in meeting heating demands over its lifetime, with the preheating period offering potential performance improvements. Implementing the BTES system in cold regions with high heating demand, such as Fairbanks, Alaska, could provide a long-term, sustainable energy solution for managing imbalanced heating and cooling loads.

15 GEOTHERMAL ENERGY↗

Demonstrating non-isothermal vacuum membrane air dehumidification for efficient next-generation air conditioning

Vacuum membrane air dehumidification has gained significant interest in recent years as a highly efficient means of air dehumidification. Prior theoretical modeling work by the authors introduced the Active Membrane Energy Exchanger (AMX) concept, which combines active heat exchange and vacuum membrane dehumidification into one non-isothermal system, and found that it could outperform other air conditioning technologies under many conditions. However, no experimental literature exists on combining active heat exchangers and vacuum membrane dehumidification. Here, the goal of the present study is to evaluate the dehumidification (mass transfer) performance of the AMX concept relative to isothermal membrane dehumidification through three main methodologies: (1) membrane material-level characterization, (2) experimental prototype development and testing, and (3) computational fluid dynamics (CFD) simulations. The dense membranes used in this work showed up to a 40% increase in water vapor permeance at cooler temperatures, and the prototype system showed up to a 6% increase in humidity removal when the air was simultaneously cooled. Furthermore, the membrane module-integrated heat exchange tubes provided additional mixing and turbulence, leading to a 4–8% increase in humidity removal. The upper limit coefficient of performance was equal to approximately 2.2, necessitating advanced system designs to improve efficiency. This study is the first to highlight that combining the cooling and vacuum dehumidification processes can improve dehumidification performance.

30 DIRECT ENERGY CONVERSION↗

Advanced defrosting techniques in air source heat pumps: A review of vapor injection, thermal energy storage, and experimental frost accumulation data

Electrification is a critical step for reducing greenhouse gas emissions from heating. Air source heat pumps (ASHPs) are a promising alternative to fossil fuel-based systems due to their high coefficients of performance (COP), dual heating and cooling capability, and lower carbon footprint. However, for ASHPs to achieve widespread adoption, they must operate reliably across all climates, including cold regions. Additionally, defrosting techniques should be energy efficient and minimally disruptive to indoor comfort. Vapor injection (VI) technology can address the high-pressure and high-temperature lift challenges encountered in low ambient conditions. More recently, in addition to enhancing heating performance, VI has also been shown to improve the speed and efficiency of reverse cycle defrosting. Likewise, thermal energy storage (TES) has steadily gained attention for its ability to serve as an auxiliary heat source during both normal operation and defrosting. This review analyzes the benefits and limitations of VI- and TES-assisted defrosting approaches. While both technologies show strong potential individually, no studies to date have explored their combined use in ASHP systems. Additionally, to support continued development of defrosting strategies, both in modeling and experimental work, it is critical to establish frost accumulation data under a range of operating conditions. By compiling the available data from the literature, this paper also highlights the limited availability of such experimental data and the wide variation in frosting and defrosting durations and termination criteria, which are often influenced by system design and test setups.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatial and temporal characterization of municipal solid waste based on resource recovery pathways

This study presents a two-year, quarterly assessment of MSW across four source sectors (residential, schools, restaurants, and grocery stores) from sixteen sites across five U.S. states. MSW was manually sorted into 27 categories and aggregated into pathway fractions: high-moisture (HM) organics, low-moisture (LM) organics, recyclable (RC) materials, and residuals for disposal. Organics represented 89 % of the MSW stream. The largest fraction was HM organics consisting of food waste (31 %) and yard waste (3 %), with large coefficient of variations (CV), 79 and 278 %, respectively, reflecting high seasonal and site variability that varied significantly (p < 0.01) across sampling periods. The HM fraction showed properties favorable for anaerobic digestion, with moisture content ranging from 56 to 95 % and volatile solids ranges of 86-95 %. In contrast, the LM and RC fractions remained more stable (plastics CV = 41 %; paper CV = 53 %) with heating values up to 26.9 MJ/kg across sources, reflecting suitability for gasification. Microstructural analysis revealed less porosity in residential waste sampled at the landfill, which can influence preprocessing efficiency and microbial accessibility. Pathway informed allocations showed that 35 % of MSW is suitable for anaerobic digestion, 36 % for gasification, and 18 % for recycling, leaving 11 % requiring landfill disposal. These results provide quantitative evidence to determine feedstock allocation, waste-to-energy system design, and the development of data-driven sustainability and resource recovery strategies within a circular bioeconomy.

09 BIOMASS FUELS↗

Coal emissions adverse human health effects associated with ultrafine/nano-particles role and resultant engineering controls

There are multiple elements which enable coal geochemistry: (1) boiler and pollution control system design parameters, (2) temperature of flue gas at collection point, (3) feed coal and also other fuels like petroleum coke, tires and biomass geochemistry and (4) fuel feed particle size distribution homogeneity distribution, maintenance of pulverisers, etc. Even though there is a large number of hazardous element pollutants in the coal-processing industry, investigations on micrometer and nanometer-sized particles including their aqueous colloids formation reactions and their behaviour entering the environment are relatively few in numbers. X-ray diffraction (XRD), High Resolution-Transmission Electron microscopy (HR-TEM)/ (Energy Dispersive Spectroscopy) EDS/ (selected-area diffraction pattern) SAED, Field Emission-Scanning Electron Microscopy (FE-SEM)/EDS and granulometric distribution analysis were used as an integrated characterization techniques tool box to determine both geochemistry and nanomineralogy for coal fly ashes (CFAs) from Brazil´s largest coal power plant. Ultrafine/nano-particles size distribution from coal combustion emissions was estimated during the tests. In addition the iron and silicon content was determined as 54.6% of the total 390 different particles observed by electron bean, results aimed that these two particles represent major minerals in the environment particles normally. These data may help in future investigations to asses human health actions related with nano-particles.

54 ENVIRONMENTAL SCIENCES↗

Investigation of two concrete thermal energy storage system configurations for continuous power production

Two Modelica concrete thermal energy storage (CTES) models are built to analyze potential CTES system designs. One design is the single pipe network design wherein a heat transfer fluid (HTF) flows in one direction during heat deposition and the opposite direction during heat removal. All pipes in the network are used for either deposition (charging) or removal (discharging). The second design is a dual pipe network design in which a network of HTF pipes carries charging fluid and a separate piping network carries discharging HTF. Operation of these two configurations to produce constant steam is evaluated. Here, results indicate that the designs are likely appropriate for different applications with the single pipe network appearing appropriate for batch energy applications and the dual pipe network for continuous energy applications.

25 ENERGY STORAGE↗

Novel artificial neural network model for instantaneous power losses and operational efficiency mapping of MW-scale vanadium redox flow battery for improved technoeconomic analysis

A novel data-driven, machine-learning-based method for modeling the instantaneous power losses of a distribution-sited 2 MW/8MWh vanadium redox flow battery (VRFB), a grid-scale electrochemical storage technology, is introduced and compared against benchmark empirical modeling approaches, including symmetric and asymmetric models, as well as a recent convex hull modeling approach. The novel loss modeling method introduces several advantages over the benchmark models and over simplistic efficiency estimates, the most significant of which is that the model can accurately reflect the stepwise and non-linear parasitic losses associated with the duty cycles of mechanical auxiliary systems like pump motor drives and blower fans. Residuals of the models are compared; the proposed data driven model features significantly improved accuracy over the benchmark models. The model's coefficient of determination is also improved relative to that of the benchmark models. Furthermore, a novel method for visualization of operational efficiency of the grid-scale storage technology is introduced. To demonstrate the benefits of the novel data-driven method for modeling the VRFB, the benchmark models and the proposed models are embedded into an Open DSS distribution network model to study two applications of the grid-scale electrical storage system: load leveling for grid support and energy arbitrage. This article demonstrates that the accuracy of the instantaneous power loss model significantly impacts the understanding of the state of charge of the VRFB. In turn, the accuracy of the efficiency modeling of the VRFB impacts the understanding of the potential economic value and technical benefits to the distribution network operators. In conclusion, the presented power loss modeling approach is, therefore, highly relevant for utility-stakeholders, battery asset owners, system engineers, system designers, and financial planners interested in evaluating or optimizing the operation of grid-scale VRFBs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Convective heat transfer in the laminar-turbulent transition region with molten salt in a circular tube

In order to understand the heat transfer characteristics of molten salt and testify the validity of the well-known empirical convective heat transfer correlations, experimental study on transition convective heat transfer with molten salt in a circular tube was conducted. Molten salt circulations were realized and operated in a specially designed system over 1000 h. The average forced convective heat transfer coefficients of molten salt were determined by least-squares method based on the measured data of flow rates and temperatures. Finally, a heat transfer correlation of transition flow with molten salt in a circular tube was obtained and good agreement was observed between the experimental data of molten salt and the well-known correlations presented by Hausen and Gnielinski, respectively. (author)

36 MATERIALS SCIENCE↗

A machine-learning-aided data recovery approach for predicting multi-material thermal behaviors in advanced test reactor capsules

Instrumented experiments conducted at test reactors are essential to the deployment of new advanced reactor systems. Designing new experiments and generating data on specific reactor conditions require significant investments in terms of both time and cost. Finite element analysis software can be used to create high-fidelity models of experiment environments in order to support the actual experiments, but computation time remains a concern in terms of applying outcomes to real-time usage of data (e.g., a digital twin [DT]). Here, the present research proposes a machine-learning (ML) aided approach to making temperature and displacement predictions based on the thickness of the outer gas gap on the experimental capsule used for in-pile demonstration of a novel new thermal conductivity probe in the Advanced Test Reactor (ATR). This capsule consisted of U10Zr fuel, a rodlet, sodium, and inner and outer capsules. Gas gaps existed between the fuel and the rodlet, and between the inner and the outer capsule. The learning data pertained to an experimental capsule's radial distributions of temperature and displacement, as obtained based on Abaqus and the physical features. For the first step of ML sequence, the temperature was predicted using three positional parameters. Next, the displacement was predicted using seven additional parameters. Each physical feature was normalized in order to be both nondimensional and standardized. The temperature and displacement predictions showed good agreement with the simulation results in all cases involving interpolation and extrapolation. Furthermore, data similarity enhancement increased the similarity between the training and the target data, thereby increasing the predictive accuracy of the ML models. In certain extrapolation cases involving limited original ML model accuracy, data similarity enhancement and data recovery was able to somewhat improve this accuracy.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Medical Device Recalls in Radiation Oncology: Analysis of US Food and Drug Administration Data, 2002-2015

Purpose: To analyze all recalls involving radiation oncology devices (RODs) from the US Food and Drug Administration (FDA)'s recall database, comparing these with non–radiation oncology device recalls to identify discipline-specific trends that may inform improvements in device safety. Methods and Materials: Recall data on RODs from 2002 to 2015 were sorted into 4 product categories (external beam, brachytherapy, planning systems, and simulation systems). Outcomes included determined cause of recall, recall class (severity), quantity in commerce, time until recall termination (date FDA determines recall is complete), and time since 510(k) approval. Descriptive statistics were performed with linear regression of time-series data. Results for RODs were compared with those for other devices by Pearson χ{sup 2} test for categorical data and 2-sample Kolmogorov-Smirnov test for distributions. Results: There were 502 ROD recalls and 9534 other class II device recalls during 2002 to 2015. Most recalls were for external beam devices (66.7%) and planning systems (22.9%), and recall events peaked in 2011. Radiation oncology devices differed significantly from other devices in all recall outcomes (P≤.04). Recall cause was commonly software related (49% vs 10% for other devices). Recall severity was more often moderate among RODs (97.6% vs 87.2%) instead of severe (0.2% vs 4.4%; P<.001). Time from 510(k) market approval to recall was shorter among RODs (P<.001) and progressively shortened over time. Radiation oncology devices had fewer recalled devices in commerce than other devices (P<.001). Conclusions: Compared with other class II devices, RODs experience recalls sooner after market approval and are trending sooner still. Most of these recalls were moderate in severity, and software issues are prevalent. Comprehensive analysis of recall data can identify areas for device improvement, such as better system design among RODs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗