At least 1,693 records · Page 94

Capturing plume behavior in complex terrain: an overview of the Nevada National Security Site Meteorological Experiment (METEX21)

METEX21 was an atmospheric tracer release experiment executed at the Department of Energy’s Nevada National Security Site (NNSS) in the southwestern U.S to study terrain-induced wind and thermodynamic conditions that influence local-scale (<5-km) plume transport under varying atmospheric forcing conditions. Meteorological observations were collected using 10-m tall meteorological towers, 2-m tall tripods with 3-d sonic anemometers, a 3-m tall eddy covariance flux tower, Doppler profiling lidars, Doppler scanning lidars, weather-balloon launched radiosondes, and a tethered balloon equipped with wind, temperature, and aerosol sensors at heights up to 800 m. A smoke tracer was released along three transects in the horizontal and vertical directions and observed with video cameras, aerosol sensors and lidars (via aerosol backscatter). The observations showed evidence of large-scale/synoptic transience as well as local-scale upslope and downslope flows, along-axis valley flows, recirculation eddies on leeward slopes, and periods of strong shear and veer aloft. The release days were classified as either synoptically-driven or locally-driven, and a single case day is presented in detail for each. Synoptically-forced days show relatively narrow smoke plumes traveling down the valley from north to south (with the predominant wind direction), with little deviation in transport direction regardless of the elevation or ground locations of the smoke releases, except near the presence of leeside recirculation eddies. Locally-forced days exhibit a wider range of plume behavior due to the combination of thermally-induced valley and slope flows, which are often flowing in different cardinal directions, and wind shear found aloft at higher altitudes and elevations. We saw evidence of smoke lofting on top of the mesas due to strong upslope flows on these days. A major finding of this experiment was the effectiveness of scanning lidars to measure 2-dimensional plume transport out to a 2–3 km distance; much farther than could be visibly observed. METEX21 was the first of three planned tracer experiments at NNSS, and future experiments will incorporate multiple tracers to improve individual plume identification so that finer resolution flow details can be attained from these measurements, as well as deploy a larger suite of meteorological instrumentation, including more temperature profiling data.

54 ENVIRONMENTAL SCIENCES↗

Remote sensing of snow

The snow parameters affecting sensor responses at different wavelengths are discussed. The effects of snow depth and background radiation on gamma ray sensors and of crystal size, contaminants, snow depth, liquid water, and surface roughness on visible and near-infrared sensors are considered. The influence of temperature, crystal size, and liquid water on thermal infrared sensors and of liquid water, crystal size, water equivalent depth, stratification, snow surface roughness, density, temperature, and soil condition on microwave sensors are addressed.

Foster, J. L.↗

Sensitivity of thermodynamic profiles retrieved from ground-based microwave and infrared observations to additional input data from active remote sensing instruments and numerical weather prediction models

Accurate and continuous estimates of the thermodynamic structure of the lower atmosphere are highly beneficial to meteorological process understanding and its applications, such as weather forecasting. In this study, the Tropospheric Remotely Observed Profiling via Optimal Estimation (TROPoe) physical retrieval is used to retrieve temperature and humidity profiles from various combinations of input data collected by passive and active remote sensing instruments, in situ surface platforms, and numerical weather prediction models. Among the employed instruments are microwave radiometers (MWRs), infrared spectrometers (IRSs), radio acoustic sounding systems (RASSs), ceilometers, and surface sensors. TROPoe uses brightness temperatures and/or radiances from MWRs and IRSs, as well as other observational inputs (virtual temperature from the RASS, cloud-base height from the ceilometer, pressure, temperature, and humidity from the surface sensors) in a physical iterative retrieval approach. This starts from a climatologically reasonable profile of temperature and water vapor, with the radiative transfer model iteratively adjusting the assumed temperature and humidity profiles until the derived brightness temperatures and radiances match those observed by the MWR and/or IRS instruments within a specified uncertainty, as well as within the uncertainties of the other observations, if used as input. In this study, due to the uniqueness of the dataset that includes all the above-mentioned sensors, TROPoe is tested with different observational input combinations, some of which also include information higher than 4 km above ground level (a.g.l.) from the operational Rapid Refresh numerical weather prediction model. These temperature and humidity retrievals are assessed against independent collocated radiosonde profiles under non-cloudy conditions to assess the sensitivity of the TROPoe retrievals to different input combinations.

54 ENVIRONMENTAL SCIENCES↗

Chemical Tool Peer Review Summary.

Chemical tracers are commonly used to characterize fracture networks and to determine the connectivity between the injection and production wells. Currently, most tracer experiments involve injecting the tracer at the injection well, manually collecting liquid samples at the wellhead of the production well, and sending the samples off for laboratory analysis. While this method provides accurate tracer concentration data, it does not provide information regarding the location of the fractures conducting the tracer between wellbores. The goal of this project is to develop chemical sensors and design a prototype tool to help understand the fracture properties of a geothermal reservoir by monitoring tracer concentrations along the depth of the well. The sensors will be able to detect certain species of the ionic tracers (mainly iodide) and pH in-situ during the tracer experiment. The proposed high-temperature (HT) tool will house the chemical sensors as well as a standard logging sensor package of pressure, temperature, and flow sensors in order to provide additional information on the state of the geothermal reservoir. The sensors and the tool will be able to survive extended deployments at temperatures up to 225 °C and high pressures to provide real-time temporal and spatial feedback of tracer concentration. Data collected from this tool will allow for the real-time identification of the fractures conducting chemical tracers between wellbores along with the pH of the reservoir fluid at various depths.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Temperature Thermometer Using Cr-Doped GdAlO3 Broadband Luminescence

A new concept has been developed for a high-temperature luminescence-based optical thermometer that both shows the desired temperature sensitivity in the upper temperature range of present state-of-the-art luminescence thermometers (above 1,300 C), while maintaining substantial stronger luminescence signal intensity that will allow these optical thermometers to operate in the presence of the high thermal background radiation typical of industrial applications. This objective is attained by using a Cr-doped GdAlO3 (Cr:GdAlO3) sensor with an orthorhombic perovskite structure, resulting in broadband luminescence that remains strong at high temperature due to the favorable electron energy level spacing of Cr:GdAlO3. The Cr:GdAlO3 temperature (and pressure) sensor can be incorporated into, or applied onto, a component s surface when a non-contact surface temperature measurement is desired, or alternatively, the temperature sensor can be attached to the end of a fiber-optic probe that can then be positioned at the location where the temperature measurement is desired. In the case of the fiber-optic probe, both the pulsed excitation and the luminescence emission travel through the fiber-optic light guide. In either case, a pulsed light source provides excitation of the luminescence, and the broadband luminescence emission is collected. Real-time temperature measurements are obtain ed using a least-squares fitting algorithm that determines the luminescence decay time, which has a known temperature dependence established by calibration. Due to the broad absorption and emission bands for Cr:GdAlO3, there is considerable flexibility in the choice of excitation wavelength and emission wavelength detection bands. The strategic choice of the GdAlO3 host is based on its high crystal field, phase stability, and distorted symmetry at the Cr3+ occupation sites. The use of the broadband emission for temperature sensing at high temperatures is a key feature of the invention and is novel since broadband luminescence emission normally shows severe thermal quenching. The tightly bound AlO6 octahedra in GdAlO3 results in a larger energy barrier to nonradiative decays than in other materials and therefore makes using broadband emission for temperature sensing possible at high temperatures. This approach results in a substantial increase in temperature capability. For example, the most commonly used Cr-doped crystal used for luminescence-based temperature measurements, ruby, has only been demonstrated up to 600 C, whereas the Cr:GdAlO3 optical thermometer under development has already been shown to exhibit useful luminescence up to 1,300 C. Because GdAlO3 is non-reactive and is stable in harsh, high-temperature environments, sensors composed of Cr:GdAlO3 will be very well suited for remote high-temperature measurements in engine or industrial environments where its intense high-temperature luminescence will stand out above significant thermal radiation background levels.

Eldridge, Jeffrey↗

Multi-Functional Applications of H-Glass Embedded with Stable Plasmonic Gold Nanoislands

Metal nanoparticles (MNPs) are synthesized using various techniques on diverse substrates that significantly impact their properties. However, among the substrate materials investigated, the major challenge is the stability of MNPs due to their poor adhesion to the substrate. Herein, it is demonstrated how a newly developed H-glass can concurrently stabilize plasmonic gold nanoislands (GNIs) and offer multifunctional applications. The GNIs on the H-glass are synthesized using a simple yet, robust thermal dewetting process. The H-glass embedded with GNIs demonstrates versatility in its applications, such as i) acting as a room temperature chemiresistive gas sensor (70% response for NO 2 gas); ii) serving as substrates for surface-enhanced Raman spectroscopy for the identifications of Nile blue (dye) and picric acid (explosive) analytes down to nanomolar concentrations with enhancement factors of 4.8 × 10 6 and 6.1 × 10 5 , respectively; and iii) functioning as a nonlinear optical saturable absorber with a saturation intensity of 18.36 × 10 15 W m -2 at 600 nm, and the performance characteristics are on par with those of materials reported in the existing literature. In conclusion, this work establishes a facile strategy to develop advanced materials by depositing metal nanoislands on glass for various functional applications.

36 MATERIALS SCIENCE↗

Design and analysis of actively-cooled, edge-transport diagnostic for long-pulsed operation in WEST

Next step fusion devices that will operate in steady-state will require complex plasma-facing components (PFCs) that can survive the harsh environment over long timescales not common in current devices. This will require robust plasma facing surfaces that are integrated with active cooling systems. In a collaboration between CEA and ORNL, a plasma-interacting diagnostic is being designed for the W Environment in Steady-state Tokamak (WEST) in Cadarache, France which requires plasma-facing protection like those needed for steady-state PFCs. This integrated diagnostic studies edge transport and impurity migration within WEST, and is planned to include imbedded temperature Langmuir probe sensors, as well as removeable sample slots for ex-situ surface analysis of plasma-material interactions. The entire assembly is expected to move into the plasma edge for periods up to 1000 s having an energy removeable capability of ∼6 kW and seeing a peak heat flux of more than 7 MW/m2. The assembly compliments WEST high fluence campaigns that plan for multiple 1000 s pulses. Within these specifications, the assembly will require a refractory metal plasma facing surface and integral cooling in order to function within the limited space allotted for such diagnostics. Because of the limited space and linear actuator needs, additive manufacturing of the high heat flux working end of the assembly is being considered which could allow for precision cooling-channels and lighter weight designs. Conceptual design along with simulation and analysis results will be presented for this complex diagnostic with novel PFCs.

Lumsdaine, Arnold↗

Chemical gases sensing properties of diamond nanocone arrays formed by plasma etching

A uniform diamond nanocone array was formed by plasma etching of diamond film in a hot filament chemical vapor deposition (HFCVD) system. A surface amorphous carbon coating layer, which is formed during CH{sub 4}/H{sub 2} plasma-etching process, was removed by Ar plasma in a reactive ion etching system. The hydrogenation of diamond nanocones was performed in H{sub 2} ambience by using the same HFCVD system. The air-diluted NH{sub 3} and NO{sub 2} gases sensing properties of the diamond cone arrays had been studied by using electric current versus measurement time characteristics at room temperature. The repeatable chemical sensing properties of the hydrogenated diamond cone array sensor are enhanced, in comparison with as-formed diamond film. Surface two-dimensional hole gas structure and greatly increased surface-to-volume ratio both play a key role for the excellent detection performance. As-formed diamond nanocone arrays show a promising prospect for applications as chemical sensor for both reducing (NH{sub 3}) and oxidizing (NO{sub 2}) gases.

36 MATERIALS SCIENCE↗

Unraveling sources of emission heterogeneity in Silicon Vacancy color centers with cryo-cathodoluminescence microscopy

Diamond color centers have proven to be versatile quantum emitters and exquisite sensors of stress, temperature, electric and magnetic fields, and biochemical processes. Among color centers, the silicon-vacancy (SiV - ) defect exhibits high brightness, minimal phonon coupling, narrow optical linewidths, and high degrees of photon indistinguishability. Yet the creation of reliable and scalable SiV - -based color centers has been hampered by heterogeneous emission, theorized to originate from surface imperfections, crystal lattice strain, defect symmetry, or other lattice impurities. Here, we advance high-resolution cryo-electron microscopy combined with cathodolumines cence spectroscopy and 4D scanning transmission electron microscopy (STEM) to elucidate the structural sources of heterogeneity in SiV - emission from nanodiamond with sub-nanometer-scale resolution. Our diamond nanoparticles are grown directly on TEM membranes from molecular-level seedings, representing the natural formation conditions of color centers in diamond. We show that individual subcrystallites within a single nanodiamond exhibit distinct zero-phonon line (ZPL) energies and differences in brightness that can vary by 0.1 meV in energy and over 70% in brightness. These changes are correlated with the atomic-scale lattice structure. We find that ZPL blue shifts result from tensile strain, while ZPL red shifts are due to compressive strain. We also find that distinct crystallites host distinct densities of SiV - emitters and that grain boundaries impact SiV - emission significantly. Finally, we interrogate nanodiamonds as small as 40 nm in diameter and show that these diamonds exhibit no spatial change to their ZPL energy. Our work provides a foundation for atomic-scale structure-emission correlation, e.g., of single atomic defects in a range of quantum and two-dimensional materials.

36 MATERIALS SCIENCE↗

Nonnuclear Experimental Capabilities to Support Design, Development, and Demonstration of Microreactors

This work provides a summary of selected experimental capabilities being developed to support nonnuclear testing and demonstration of technology in support of microreactors under the U.S. Department of Energy’s (DOE’s) Microreactor Program. Major capabilities include the Single Primary Heat Extraction and Removal Emulator (SPHERE) and the Microreactor Agile Non-nuclear Experimental Test Bed (MAGNET). The SPHERE facility allows for controlled testing of the steady-state and transient heat rejection capabilities of a single heat pipe using electrical heaters that simulate nuclear heating. The facility is capable of monitoring axial temperature profiles along the heat pipe and surrounding test articles during startup, steady-state operation, and transients. Instrumentation includes noncontact infrared thermal imaging, surface thermocouples, spatially distributed fiber optic temperature and strain sensors, electrical power meters, and a water-cooled, gas-gap calorimeter for quantifying heat rejection from the heat pipe. The facility can be operated under both vacuum and inert-gas conditions. The MAGNET facility is a large-scale, 250-kW electrically heated microreactor test bed to enable nonnuclear experimental evaluation of a variety of microreactor concepts. It can be supplied to electrically heat a scaled section of a microreactor and further test the capabilities of heat rejection systems. The initial MAGNET experiments will support technology maturation and reduce uncertainty and risk associated with the design, operation, and deployment of monolithic heat pipe–based reactors. However, this test bed can broadly be applied to multiple microreactor concepts to evaluate a wide range of thermal-hydraulic and structural phenomena such as interface coupling with power conversion units and other collocated systems. MAGNET can evaluate integral thermomechanical effects during electrical heating of an array of heat pipes in a larger test article. Examples of initial testing will include thermal stresses in the monolith and the impact of debonding of a heat pipe from the core block and how that failure could impact surrounding heat pipes, i.e., understanding the potential for cascading failure. This work also discusses some modeling capabilities that can support experiment design, analysis, and interpretation, including the heat pipe code Sockeye and a comparison of thermal-structural simulations performed using ABAQUS and STAR-CCM+.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Vortex Induced Vibration Test of the WITT Device in a Tidal Channel

Fluid flow around a bluff body causes vibrations as the boundary layer separates and vortices are shed. This phenomenon, called vortex induced vibration (VIV), is minimized in most engineering applications, but can be utilized for power generation. Vortex induced vibration has potential for energy harvesting in low velocity water flows and therefore could open many locations to marine renewable energy. Here we present the results of a field test of a device that utilizes VIV to harvest energy from flow in a tidal channel. The pendulum-type device has been designed to generate electricity from motion around and along three axes. It is named the Whatever Input to Torsion Transfer (WITT) energy device and in this test is mounted on top of a pipe. During the field test, the WITT generated electricity at flow velocities from 0.27 to 2.82 m/s. The field test has proven that the WITT can utilize VIV to produce electricity and charge a battery in tidal flows with velocities as low as 0.27 m/s. In the future, the electricity could be used to charge a battery for ocean observation instruments such as temperature and nitrate sensors. In-situ power generation by the WITT would extend deployment times and increase the frequency of measurements.

Branch, Ruth A.↗

Epidermal Electronics

We report classes of electronic systems that achieve thicknesses, effective elastic moduli, bending stiffnesses, and areal mass densities matched to the epidermis. Unlike traditional wafer-based technologies, laminating such devices onto the skin leads to conformal contact and adequate adhesion based on van der Waals interactions alone, in a manner that is mechanically invisible to the user. We describe systems incorporating electrophysiological, temperature, and strain sensors, as well as transistors, light-emitting diodes, photodetectors, radio frequency inductors, capacitors, oscillators, and rectifying diodes. Solar cells and wireless coils provide options for power supply. Furthermore, we used this type of technology to measure electrical activity produced by the heart, brain, and skeletal muscles and show that the resulting data contain sufficient information for an unusual type of computer game controller.

42 ENGINEERING↗

Aerosol Observing System Surface Meteorology (AOSMET) Instrument Handbook

The U.S. Department of Energy (DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Aerosol Observing System (AOS) surface meteorology instrument is an ancillary sensor that provides temperature, relative humidity, pressure, wind speed and direction, and precipitation data relevant to the AOS. It consists of a Vaisala WXT520 Weather Transmitter mounted on top of the AOS aerosol inlet, at a height of approximately 10 meters.

54 ENVIRONMENTAL SCIENCES↗

Microcalorimetry for High-Resolution X-Ray Spectroscopy

Magnetic Microcalorimeters (MMCs) are gamma-ray detectors with an energy resolution 10x higher than high-purity germanium detectors. They can increase the accuracy of non-destructive analysis of nuclear materials, enable the detection of new isotopes (e.g. Pu-242 of U-236), and improve nuclear data in cases where Ge detectors are limited by line overlap. MMCs consist of a magnetic sensor operated at temperatures below 50 mK, and they infer gamma-ray energies from the change in magnetization due to the temperature increase after gamma-ray absorption. The goal of this project is to further increase the energy resolution and sensitivity of MMC gamma detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FY17 Safeguards Factsheet for LL16-MagMicro-PD1La

Magnetic Microcalorimeters (MMCs) are gamma-ray detectors with an energy resolution 10x higher than high-purity germanium detectors. They can improve nuclear data, enable the detection of new isotopes (e.g. Pu-242 of U-236), and increase the accuracy of non-destructive analysis of nuclear materials in cases where Ge detectors are limited by line overlap. MMCs consist of a magnetic sensor operated at temperatures below 50 mK, and they infer gamma-ray energies from the change in magnetization due to the temperature increase after gamma-ray absorption. The goal of this project is to further increase the energy resolution and sensitivity of MMC gamma detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Raman Spectroscopy for the On-Line Analysis of Oxidation States of Oxygen Carrier Particles (Final Report)

The need for cleaner energy systems, including CO 2 capture technologies, is driving the current development of chemical looping technologies such as chemical looping combustion (CLC) and chemical looping gasification (CLG). Specific processes that are under development for using solid fuels are in-situ Gasification Chemical-Looping Combustion (iG-CLC) and Chemical Looping with Oxygen Uncoupling (CLOU). Chemical looping is based on using oxygen carriers (e.g., iron oxides, copper oxides, calcium sulfates, etc.) to provide the oxygen for the reaction with the fuel. In order to optimize the overall process performance, it is critical that the properties of the oxygen carriers are well-defined and maintained for their specific purpose during the different stages of the CLC process. One of the critical properties of the oxygen carrier is its oxidation state (e.g., content of Fe 2 O 3 vs. Fe 3 O 4 ) as it affects the fundamental operation of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of oxygen carriers is lacking and new sensors need to be developed. The goal of this project was to evaluate the potential of Raman spectroscopy as a sensor for the on-line analysis of the oxidation state of oxygen carrier particles. Oxygen carrier particles (OCPs) of interest include iron oxides, copper oxides, calcium sulfite, and calcium sulfate, with particle sizes typically less than 0.5 mm diameter. The expected operating conditions of the sensor include OCP temperatures in the range of 800 °C to 1000 °C, and pressures of about 10 atm. We evaluated continuous wave (cw), Quasi cw, pulsed, and time-gated Raman spectroscopy at multiple wavelengths (355 nm, 360 nm, 532 nm, 633 nm, 785 nm). Samples included iron oxides, copper oxides, calcium sulfate, and a custom sample provided by NETL for temperatures beyond 1000 °C. Our findings can be summarized as follows: Calcium sulfate can be detected via cw and pulsed 532 nm Raman spectroscopy at temperatures above 1100 °C.; Hematite (Fe 2 O 3 ) Raman spectra can be detected at temperatures of 700 °C via cw 360 nm, 1089 °C with cw 532 nm, 400 °C with cw 633 and 600 °C with cw 785 nm lasers; Magnetite (Fe 3 O 4 ) can be detected via cw 532 nm Raman spectroscopy up to 600 °C; Mixtures of Fe2O3 and Fe 3 O 4 can be distinguished for temperatures up to 600 °C using 532 nm; Copper oxides did not yield suitable signals at elevated temperatures; The custom NETL samples did not yield suitable signals at elevated temperatures. Raman spectroscopy would be a suitable approach for calcium sulfate as this material provides a very strong Raman signal at high temperatures. Oxygen carrier particles of higher interest such as metal oxides, however, do not yield a strong-enough signal at elevated temperatures. As such, Raman spectroscopy is not suitable to differentiate the oxidation state of these materials at temperatures above 600 °C.

01 COAL, LIGNITE, AND PEAT↗

Aerosol Observing System Surface Meteorology (AOSMET) Instrument Handbook

The aerosol observing system (AOS) surface meteorology instrument is an ancillary sensor that provides temperature, relative humidity, pressure, wind speed and direction, and precipitation data relevant to the AOS. It consists of a Vaisala weather transmitter (WXT520 or WXT530) mounted on top of the AOS aerosol inlet, at a height of approximately 10 meters.

54 ENVIRONMENTAL SCIENCES↗

Raman Spectroscopy for the On-Line Analysis of Oxidation States of Oxygen Carrier Particles

The need for cleaner energy systems, including CO 2 capture technologies, is driving the current development of chemical looping technologies such as chemical looping combustion (CLC) and chemical looping gasification (CLG). Specific processes that are under development for using solid fuels are in-situ Gasification Chemical-Looping Combustion (iG-CLC) and Chemical Looping with Oxygen Uncoupling (CLOU). Chemical looping is based on using oxygen carriers (e.g., iron oxides, copper oxides, calcium sulfates, etc.) to provide the oxygen for the reaction with the fuel. In order to optimize the overall process performance, it is critical that the properties of the oxygen carriers are well-defined and maintained for their specific purpose during the different stages of the CLC process. One of the critical properties of the oxygen carrier is its oxidation state (e.g., content of Fe 2 O 3 vs. Fe 3 O 4 ) as it affects the fundamental operation of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of oxygen carriers is lacking and new sensors need to be developed. The goal of this project was to evaluate the potential of Raman spectroscopy as a sensor for the on-line analysis of the oxidation state of oxygen carrier particles. Oxygen carrier particles (OCPs) of interest include iron oxides, copper oxides, calcium sulfite, and calcium sulfate, with particle sizes typically less than 0.5 mm diameter. The expected operating conditions of the sensor include OCP temperatures in the range of 800 °C to 1000 °C, and pressures of about 10 atm. We evaluated continuous wave (cw), Quasi cw, pulsed, and time-gated Raman spectroscopy at multiple wavelengths (355 nm, 360 nm, 532 nm, 633 nm, 785 nm). Samples included iron oxides, copper oxides, calcium sulfate, and a custom sample provided by NETL for temperatures beyond 1000 °C. Our findings can be summarized as follows: Calcium sulfate can be detected via cw and pulsed 532 nm Raman spectroscopy at temperatures above 1100 °C. Hematite (Fe 2 O 3 ) Raman spectra can be detected at temperatures of 700 °C via cw 360 nm, 1089 °C with cw 532 nm, 400 °C with cw 633 and 600 °C with cw 785 nm lasers. Magnetite (Fe 3 O 4 ) can be detected via cw 532 nm Raman spectroscopy up to 600 °C. Mixtures of Fe 2 O 3 and Fe 3 O 4 can be distinguished for temperatures up to 600 °C using 532 nm. Copper oxides did not yield suitable signals at elevated temperatures. The custom NETL samples did not yield suitable signals at elevated temperatures. Raman spectroscopy would be a suitable approach for calcium sulfate as this material provides a very strong Raman signal at high temperatures. Oxygen carrier particles of higher interest such as metal oxides, however, do not yield a strong-enough signal at elevated temperatures. As such, Raman spectroscopy is not suitable to differentiate the oxidation state of these materials at temperatures above 600 °C.