Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

TH-AB-201-07: Filmless Treatment Localization QA for the CyberKnife System

Purpose: Accuray recommends daily evaluation of the treatment localization and delivery systems (TLS/TDS) of the CyberKnife. The vendor-provided solution is a Winston-Lutz-type test that evaluates film shadows from an orthogonal beam pair (known as AQA). Since film-based techniques are inherently inefficient and potentially inconsistent and uncertain, this study explores a method which provides a comparable test with greater efficiency, consistency, and certainty. This test uses the QAStereoChecker (QASC, Standard Imaging, Inc., Middleton, WI), a high-resolution flat-panel detector with coupled fiducial markers for automated alignment. Fiducial tracking is used to achieve high translational and rotational position accuracy. Methods: A plan is generated delivering five circular beams, with varying orientation and angular incidence. Several numeric quantities are calculated for each beam: eccentricity, centroid location, area, major-axis length, minor-axis length, and orientation angle. Baseline values were acquired and repeatability of baselines analyzed. Next, errors were induced in the path calibration of the CK, and the test repeated. A correlative study was performed between the induced errors and quantities measured using the QASC. Based on vendor recommendations, this test should be able to detect a TLS/TDS offset of 0.5mm. Results: Centroid shifts correlated well with induced plane-perpendicular offsets (p < 0.01). Induced vertical shifts correlated best with the absolute average deviation of eccentricities (p < 0.05). The values of these metrics which correlated with the threshold of 0.5mm induced deviation were used as individual pass/fail criteria. These were then used to evaluate induced offsets which shifted the CK in all axes (a clinically-realistic offset), with a total offset of 0.5mm. This test provided high and specificity and sensitivity. Conclusion: From setup to analysis, this filmless TLS/TDS test requires 4 minutes, as opposed to 15–20 minutes for film-based methods. The techniques introduced can potentially isolate errors in individual joints of the CK robot. Spectrum Medical Physics, LLC of Greenville, SC has a consulting contract with Standard Imaging of Middleton, WI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Control Volume Finite Element Method with Multidimensional Edge Element Scharfetter-Gummel upwinding. Part 2. Computational Study

In [3] we proposed a new Control Volume Finite Element Method with multi-dimensional, edge- based Scharfetter-Gummel upwinding (CVFEM-MDEU). This report follows up with a detailed computational study of the method. The study compares the CVFEM-MDEU method with other CVFEM and FEM formulations for a set of standard scalar advection-diffusion test problems in two dimensions. The first two CVFEM formulations are derived from the CVFEM-MDEU by simplifying the computation of the flux integrals on the sides of the control volumes, the third is the nodal CVFEM [2] without upwinding, and the fourth is the streamline upwind version of CVFEM [10]. The finite elements in our study are the standard Galerkin, SUPG and artificial diffusion methods. All studies employ logically Cartesian partitions of the unit square into quadrilateral elements. Both uniform and non-uniform grids are considered. Our results demonstrate that CVFEM-MDEU and its simplified versions perform equally well on rectangular or nearly rectangular grids. However, performance of the simplified versions significantly degrades on non-affine grids, whereas the CVFEM-MDEU remains stable and accurate over a wide range of mesh Peclet numbers and non-affine grids. Compared to FEM formulations the CVFEM-MDEU appears to be slightly more dissipative than the SUPG, but has much less local overshoots and undershoots.

97 MATHEMATICS AND COMPUTING↗

AGC-1 Sister Specimen Testing Data Report

The AGC-1 irradiation capsule will provide irradiation creep design data and data for the effects of irradiation creep on key physical properties of several candidate graphites for the Next Generation Nuclear Plant (NGNP). A further objective of the AGC-1 creep capsule is to provide design data for the effects of neutron irradiation on the properties of a range of NGNP candidate graphites, Characterization, both non-destructively and destructively, of AGC-1 graphite creep “sister” specimens for the major grades, i.e., NBG-17, NBG-18, H-451, PCEA, IG-110, and IG-430 has been performed and is reported here. The properties measured were: bulk density by mensuration and Hg-immersion; tensile properties, including strength, stress-strain behavior, static Young’s modulus, and strain to failure; compressive properties, including strength, stress-strain behavior, static elastic modulus, and strain to failure; elastic constants, including dynamic Young’s modulus (fundamental frequency method), and sonic elastic constants, including Young’s modulus, shear modulus, and Poisson’s ratio; pore size distribution (by Hg-intrusion); crystal structure (by x-ray diffraction, XRD); specific heat (elevated temperature), and thermal conductivity (elevated temperature). Significant differences were noted in the physical properties between the grades examined and are attributed to factors such as density, structure (filler particle size and pore size) and the forming method. Some difficulties were encountered with mechanical testing of small (sub-standard) size specimens due to volume and grain size-section size effects. These difficulties are well understood and are an inevitable consequence of conducting property evaluations on small irradiation specimens. These data are judged to be sufficient to yield adequate fractional change in properties when combined with post-irradiation characterization data. However, the complication associated with small specimen testing reinforces the need to conduct full characterization programs to establish the baseline design properties of the NGNP candidate graphites. A sufficient body of experimental data has been acquired from the AGC-1 creep “sister” specimens to fully characterize the properties of interest for the major grades included in the AGC-1 capsule. These data, in combination with the pre-irradiation characterization data packages for the actual AGC-1 creep and control specimens, provide a sound and sufficient pre-irradiation data set for determination of the effects of irradiation induced dimensional change and creep strain on the physical properties of the nuclear graphite grades in the AGC-1 capsule.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurements of Hydrogen Generation Rates using a Sealed Reactor System - 19428

Sealed reactor tests were performed to measure the hydrogen generation rate (HGR) from stored radioactive waste at the Savannah River Site. HGR may be very low, on the order of 7.5 x 10{sup -13} (m{sup 3}/h)/L [that is, cubic meters of H{sub 2} generated per hour per liter of radioactive liquid waste, or 10{sup -10} (ft{sup 3}/h)/gal]. Because the estimated HGR limit of detection for an open, continuous flow, system is approximately 7.5 x 10{sup -10} (m{sup 3}/h)/L [or 10{sup -7} (ft{sup 3}/h)/gal], a more sensitive method was needed. By accumulating generated gasses in a sealed system without a continuous purge gas, the resulting concentrations can increase the sensitivity of measurement, which is based on time of heating. In 2017, Savannah River Remediation declared a Potential Inadequacy in the Safety Analysis related to the potential thermal decomposition of organics that generate hydrogen in each of three Liquid Waste facilities: Concentration, Storage and Transfer Facility, Saltstone Production Facility, and the Defense Waste Processing Facility. The research for this study concerns low activity waste of Tank 50, which feeds the Saltstone Production Facility. This study evaluated the impact of organics including formate on the generation of H{sub 2}. Samples of SRS Tank 50 waste, which is a nominal 5 molar sodium salt solution, were sealed in stainless steel reactors and held at varying temperatures, e.g., 50 deg. C, 75 deg. C, 100 deg. C, and 120 deg. C, to determine if organic compounds are decomposing into H2. The experiments included trace solids used to stabilize waste in grout, e.g., grout-premix and Blast Furnace Slag, to determine if any solid phase reactions are present, which would accelerate or inhibit the generation of H{sub 2} at these temperatures. This paper describes the sealed reactors designed and constructed at Savannah River National Laboratory and the radioactive tests that were performed to measure HGR in both oxic and anoxic atmospheres. The shakedown tests showed the sealed reactors to be leak tight and hydrogen concentrations from calibrated standards could be accurately measured. Previous simulant tests helped to perfect the test methods and better design the radioactive tests. The radioactive results showed that the rate of hydrogen generated from Tank 50 waste, over a range of temperatures from 30 deg. C up to 120 deg. C, is bounded by an empirical relation (Hu Equation) that can be used to approximate HGRs in Tank 50 radioactive waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Some Observations About the Drop-weight Explosive Sensitivity Test

The apparent simplicity of the drop-weight apparatus for explosive sensitivity testing hides the reality that it is actually a complex integrated test of both ignition and growth of deflagration. Although the drop-weight test is undeniably a useful screening test for explosive properties, a misunderstanding of the technique’s limitations has blinded many researchers to its limited wider applicability. This monograph discusses how the test actually works, the significant engineering difficulties with standardization between machines, which types of explosives are suited to the test and which are not, and finally offers a few suggestions for alternatives when a more quantified understanding of a material’s response is required for other applications.

36 MATERIALS SCIENCE↗

Adaptive Reweighted Variance Estimation for Monte Carlo Eigenvalue Simulations

Monte Carlo (MC) simulation is used to solve the eigenvalue form of the Boltzmann transport equation to estimate various parameters such as fuel pin flux distributions that are crucial for the safe and efficient operation of nuclear systems (e.g., a nuclear reactor). Monte Carlo eigenvalue simulation uses a sample mean over many stationary cycles (iterations) to estimate various parameters important to nuclear systems. A variance estimate of the sample mean is often used for calculating the confidence intervals. However, MC eigenvalue simulation variance estimators that ignore the intercycle correlation underestimate the true variance of the estimated quantity. This paper presents novel data-adaptive approaches based on a simple autoregressive (AR) model and sigmoid functions to improve MC variance estimation. The standard MC sample-based variance estimator (or naïve estimator) and the spectral density–based MC variance estimator are enhanced by adding data-adaptive components that reduce their bias and improve performance. By investigating the frequency pattern of the AR(1) (order 1) model, two adaptive spectral estimators and one adaptive naïve estimator are proposed. The proposed estimators manifest superior performance when applied to three test problems compared to the standard spectral density–based estimator previously introduced by the authors. In conclusion, these new estimators are straightforward, as they use online algorithms and do not require storage of tallies from all active cycles.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Model-based verification of I and C specifications - 184

In the field of nuclear I and C (Instrumentation and Control), the late detection of errors in the specifications and the design of I and C has a strong impact in terms of time and money. The early verification in the V cycle of I and C functions is a key issue to capture inconsistencies and errors before the implementation and on-site tests. EDF, in the framework of the collaborative project CONNEXION, has investigated methods based on simulation to formalize I and C requirements and to evaluate them at the conceptual and basic design phases. Behavioral models of the physic parts of the system and I and C functions, described as functional diagrams, are co-simulated in an integration environment based on the FMI (Functional Mockup Interface) standard. In this specific environment, test scenarios are performed on these models. These scenarios are defined on the basis of a high level model of the studied system that takes into account the states to cover (in normal and degraded situations). Requirements, once formalized, are translated into observers that evaluate their fulfillment during the simulations. Simulation logs are then a tool for the designer to analyze the causes of the possible non-fulfillment of requirements and to fix the corresponding errors in the specifications. The proposed methodology enables to detect errors in the specifications of I and C functions, to generate automatically functional test scenarios taking into account the coverage of the requirements and all the different operational modes of the system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Role of Mathematical Methods in Efficiency Calibration and Uncertainty Estimation in Gamma Based Non-Destructive Assay - 12311

Mathematical methods are being increasingly employed in the efficiency calibration of gamma based systems for non-destructive assay (NDA) of radioactive waste and for the estimation of the Total Measurement Uncertainty (TMU). Recently, ASTM (American Society for Testing and Materials) released a standard guide for use of modeling passive gamma measurements. This is a testimony to the common use and increasing acceptance of mathematical techniques in the calibration and characterization of NDA systems. Mathematical methods offer flexibility and cost savings in terms of rapidly incorporating calibrations for multiple container types, geometries, and matrix types in a new waste assay system or a system that may already be operational. Mathematical methods are also useful in modeling heterogeneous matrices and non-uniform activity distributions. In compliance with good practice, if a computational method is used in waste assay (or in any other radiological application), it must be validated or benchmarked using representative measurements. In this paper, applications involving mathematical methods in gamma based NDA systems are discussed with several examples. The application examples are from NDA systems that were recently calibrated and performance tested. Measurement based verification results are presented. Mathematical methods play an important role in the efficiency calibration of gamma based NDA systems. This is especially true when the measurement program involves a wide variety of complex item geometries and matrix combinations for which the development of physical standards may be impractical. Mathematical methods offer a cost effective means to perform TMU campaigns. Good practice demands that all mathematical estimates be benchmarked and validated using representative sets of measurements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Update on Development of a U.S. Rail Transport Capability for Spent Nuclear Fuel and High-Level Waste - 19092

This paper provides an overview of the progress to date, and discussion of the path forward, related to designing, fabricating and testing prototype railcars that will comply with the safety standard S-2043. This standard was developed by the Association of American Railroads (AAR) specifically for railcars used to transport High-Level Radioactive Material (HLRM). AAR defines the term HLRM to include both spent nuclear fuel (SNF) and high-level radioactive waste (HLW). DOE is in the process of developing and testing prototype railcars that will satisfy Standard S-2043. This is a technical paper that does not take into account the contractual limitations under the Standard Contract for Disposal of Spent Nuclear Fuel and/or High-Level Radioactive Waste (Standard Contract) (10 CFR Part 961). Under the provisions of the Standard Contract, DOE does not consider spent nuclear fuel in multi-assembly canisters to be an acceptable waste form, absent a mutually agreed to contract amendment. To the extent discussions or recommendations in this paper conflict with the provisions of the Standard Contract, the Standard Contract provisions prevail. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Update on Development of a U.S. Rail Transport Capability for Spent Nuclear Fuel and High-Level Waste - 20466

This paper provides an overview of the progress to date, and discussion of the path forward, related to designing, fabricating and testing prototype railcars that will comply with the safety standard S-2043. This standard was developed by the Association of American Railroads (AAR) specifically for railcars used to transport High-Level Radioactive Material (HLRM). AAR defines the term HLRM to include both spent nuclear fuel (SNF) and high-level radioactive waste (HLW). DOE is in the process of developing and testing prototype railcars that will satisfy Standard S-2043. This is a technical paper that does not take into account contractual limitations or obligations under the Standard Contract for Disposal of Spent Nuclear Fuel and/or High-Level Radioactive Waste (Standard Contract) (10 CFR Part 961). For example, under the provisions of the Standard Contract, spent nuclear fuel in multi-assembly canisters is not an acceptable waste form, absent a mutually agreed to contract amendment. To the extent discussions or recommendations in this paper conflict with the provisions of the Standard Contract, the Standard Contract governs the obligations of the parties, and this paper in no manner supersedes, overrides, or amends the Standard Contract. This paper reflects technical work which could support future decision making by the Department of Energy (DOE or Department). No inferences should be drawn from this paper regarding future actions by DOE, which are limited both by the terms of the Standard Contract and a lack of Congressional appropriations for the Department to fulfill its obligations under the Nuclear Waste Policy Act including licensing and construction of a spent nuclear fuel repository. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of Different Variants of the U.S. Army Occupational Physical Assessment Test

The U.S. Army Occupational Physical Assessment Test (OPAT) is a pre-enlistment physical employment screening assessment developed to place recruits and soldiers into Military Occupational Specialties (MOSs) based on their physical capabilities in order to optimize performance and limit injury. The OPAT consists of the seated power throw (SPT), strength deadlift (SDL), standing long jump, and interval aerobic run. During the scientific validation of the OPAT, two variants of the SPT and two variants of the SDL were used. Although the OPAT was validated using both variants for each test, U.S. Army scientists and policymakers have received queries regarding how these variants compare to each other. Therefore, the purpose of this study was to compare different variants of the SPT and SDL. Thirty-two participants (14 male and 18 female) between the ages of 18 and 42 years visited the laboratory on one occasion and performed two variants of the SPT (seated on the ground [the current OPAT standard] versus seated in a chair with a 35 cm seat height) and two variants of the SDL (using a hex-bar [the current OPAT standard] versus using paired dumbbells). Testing order for the different variants was randomized. The protocol was approved by the U.S. Army Medical Research and Development Command Institutional Review Board. Performing the SPT from a chair significantly (P < .05) increased performance when compared to performing the SPT from the ground (5.4 ± 1.3 m versus 5.0 ± 1.4 m, respectively). Values for the two SPT variants were correlated (tau = 0.90). Performing the SDL using the hex-bar significantly increased the maximal weight lifted when compared to performing the SDL using paired dumbbells (86.9 ± 18.4 kg versus 83.1 ± 18.0 kg, respectively). Values for the two SDL variants were correlated (tau = 0.83). Performing different variants of the SPT and SDL influenced the resulting score. Although these findings do not alter the administration or scoring of the OPAT, they do provide a valuable reference in the event of future inquiries regarding the development of the OPAT.

General & Internal Medicine↗

Dark Energy in Light of Multi-Messenger Gravitational-Wave Astronomy

Gravitational waves (GWs) provide a new tool to probe the nature of dark energy (DE) and the fundamental properties of gravity. We review the different ways in which GWs can be used to test gravity and models for late-time cosmic acceleration. Lagrangian-based gravitational theories beyond general relativity (GR) are classified into those breaking fundamental assumptions, containing additional fields and massive graviton(s). In addition to Lagrangian based theories we present the effective theory of DE and the $\mu$-$\Sigma$ parametrization as general descriptions of cosmological gravity. Multi-messenger GW detections can be used to measure the cosmological expansion (standard sirens), providing an independent test of the DE equation of state and measuring the Hubble parameter. Several key tests of gravity involve the cosmological propagation of GWs, including anomalous GW speed, massive graviton excitations, Lorentz violating dispersion relation, modified GW luminosity distance and additional polarizations, which may also induce GW oscillations. We summarize present constraints and their impact on DE models, including those arising from the binary neutron star merger GW170817. Upgrades of LIGO-Virgo detectors to design sensitivity and the next generation facilities such as LISA or Einstein Telescope will significantly improve these constraints in the next two decades.

79 ASTRONOMY AND ASTROPHYSICS↗

Bounding Pressure and Flammability Evaluations of Aluminum-Clad Spent Nuclear Fuel Department of Energy Standard Canisters

This paper presents bounding pressure and flammability evaluations for DOE Standard Canister loaded with DOE-managed aluminum-clad spent nuclear fuel (ASNF). The objective of these evaluations is to gain confidence in the safety and feasibility of possible loading configurations for extended (>50 years) periods of dry storage, with particular focus on the dry storage canister pressures and potential for formation of a flammable atmosphere. The primary concern about the extended dry storage of ASNF is radiolytic gas generation. The aluminum cladding of these materials tends to corrode, and these corrosion products—typically aluminum oxides, such as boehmite, bayerite, or gibbsite—could carry water. This makes ASNF dry storage canisters difficult to dry. The gamma radiation field in dry storage environments could cause a radiolytic breakdown of residual water, forming chemical species such as molecular hydrogen (H2). The release of these species could increase the canister pressure and lead to the generation of a flammable canister atmosphere. The bounding evaluations presented within this study surmise conservative, but credible, conditions and processes. This includes the assumption of a full breakdown of a large quantity of free, physisorbed, and chemisorbed water (bound in a trihydrate, i.e., Al2O3 • 3H2O, layer). The considered dry storage configurations include a ~3 m (10 ft) long, ~46 cm (18 in) diameter (10 x 18) DOE Standard Canister loaded with 32 Advanced Test Reactor (ATR) ASNF elements, and a ~3 m (10 ft) long, ~61 cm (24 in) (10 x 24) diameter DOE Standard Canister loaded with 40 ATR ASNF elements. While the results of this study indicate the possibility of atmospheric hydrogen concentrations above the lower flammability limit, insufficient concentrations of oxygen will prevent the formation of flammable atmospheres. The maximum credible pressures remain well within the structural limits of the DOE Standard Canister.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultrasonic Testing (UT) and Computed Tomography (CT) Comparative Scanning of Proposed Additive Manufacturing Reference Standard

This report presents qualitative results of ultrasonic full matrix capture/total focusing method (FMC/TFM) scanning of two series of blocks, additively manufactured by powder bed fusion, containing a variety of internal features and structures that would not be achievable by conventional manufacturing techniques. The purpose of the first series of additively manufactured (AM) blocks was to explore the possibility of building calibration blocks for FMC/TFM ultrasonic testing (UT). It was confirmed that AM is a suitable candidate for generation of unusual and novel reflector forms, such as rotating slots, purposely embedded voids, and tapering holes, and that FMC/TFM was very capable of characterizing them. The intended use of the second series of AM blocks was as UT reference blocks to characterize the AM process quality or the interrogating UT technique. The larger block in this series was scanned from multiple faces, using multiple UT methods (conventional UT and FMC/TFM) and X-ray computed tomography for comparative purposes. The performance of each method was quantified by a metric corresponding to the detection limit of each feature, and the quantitative results are discussed.

36 MATERIALS SCIENCE↗

Adhesion Testing of Direct-Write Printed Ink on Metallic Structural Components

The successful adoption of additive manufacturing for the rapid prototyping of direct-write printed electronics requires the establishment of quantifiable metrics that can interrogate device performance. One measure of performance is the adhesion strength between the substrate and printed film interface, which is critical since the strength of this interface can dictate the accuracy and reliability of the printed device. In this work, a non-contact laser-induced spallation technique was used to quantify the adhesion of silver printed films on aluminum alloy substrates. The laser-based method was compared to a standardized pull-off adhesion test, which provided baseline measurements of adhesion strength. The sintering conditions were shown to play an important role in the film-substrate adhesion strength, as well as the cohesion and ductility of the film itself. The methods and results described in this work support the establishment of process control steps that are necessary for quickly verifying the reliability of printed devices prior to their deployment in critical experiments.

Adhesion test↗

ESTIMATION UNCERTAINTY IN THE DETERMINATION OF THE MASTER CURVE REFERENCE TEMPERATURE

The Master Curve Reference Temperature, T0, characterizes the fracture performance of structural steels in the ductile-to-brittle transition region. For a given material, this reference temperature is estimated via fracture toughness testing. A methodology is presented to compute the standard error of an estimated T0 value from a finite sample of toughness data, in a unified manner for both single temperature and multiple temperature test methods. Using the asymptotic properties of maximum likelihood estimators, closed-form expressions for the standard error of the estimate of T0 are presented for both test methods. This methodology includes statistically rigorous treatment of censored data, which represents an advance over the current ASTM E1921 methodology. Through Monte Carlo simulations of realistic single temperature and multiple temperature test plans, the recommended likelihood-based procedure is shown to provide better statistical performance than the methods in the ASTM E1921 standard.

36 MATERIALS SCIENCE↗

Standards and Best Practices for Solar Measurements

NREL leads and contributes to the development of radiometric standards and associated best practices through the American Society for Testing Materials (ASTM) International and others, such as the International Energy Agency (IEA) and International Organization for Standardization (ISO). Development of best practices and consensus standards in solar measurement enables industry to develop widely accepted protocols for various stages of solar project development and operations. This reduces barriers to seeking financing and reduces warranty costs. These standards and best practices play an essential role in all aspects of weathering and durability, including standard conditions, methods and instrumentation, accelerated testing, and service lifetime of materials systems.

14 SOLAR ENERGY↗