Search NASA⌕ Search

SEARCH · Search NASA

Results for “VAPORIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Water vapor column abundance retrievals during FIFE

A variation of the modified Langley plot algorithm is reported here and applied to the retrieval of atmospheric water column abundance from a filtered sunphotometer. In this new methodology an absorption data base (LOWTRAN 7) is used to compute a water abundance versus transmittance curve of growth, rather than the square-root dependence previously assumed. Validation of the technique is provided from an uncertainty analysis, and plans to further validate using Fourier transform spectrometers are detailed. The new sunphotometer technique is used to report local column water vapor during the First ISLSCP Field Experiment (FIFE), and comparisons are made with abundances retrieved via FIFE radiosonde observations. The sunphotometer data can best be utilized, however, to in turn validate data from airborne or in-orbit measurements of water vapor. With these flight sensors, horizontal and topographic variability within the scene can be viewed. An example of the airborne data set is given using an image from the airborne visible infrared imaging spectrometer, as acquired on August 31, 1990.

Bruegge, Carol J.↗

Single liquid source plasma-enhanced metalorganic chemical vapor deposition of high-quality YBa2Cu3O(7-x) thin films

High quality YBa2Cu3O(7-x) films were grown in-situ on LaAlO3 (100) by a novel single liquid source plasma-enhanced metalorganic chemical vapor deposition process. The metalorganic complexes M(thd) (sub n), (thd = 2,2,6,6-tetramethyl-3,5-heptanedionate; M = Y, Ba, Cu) were dissolved in an organic solution and injected into a vaporizer immediately upstream of the reactor inlet. The single liquid source technique dramatically simplifies current CVD processing and can significantly improve the process reproducibility. X-ray diffraction measurements indicated that single phase, highly c-axis oriented YBa2Cu3O(7-x) was formed in-situ at substrate temperature 680 C. The as-deposited films exhibited a mirror-like surface, had transition temperature T(sub cO) approximately equal to 89 K, Delta T(sub c) less than 1 K, and Jc (77 K) = 10(exp 6) A/sq cm.

Zhang, Jiming↗

Isomerization reaction dynamics and equilibrium at the liquid-vapor interface of water. A molecular-dynamics study

The gauche-trans isomerization reaction of 1,2-dichloroethane at the liquid-vapor interface of water is studied using molecular-dynamics computer simulations. The solvent bulk and surface effects on the torsional potential of mean force and on barrier recrossing dynamics are computed. The isomerization reaction involves a large change in the electric dipole moment, and as a result the trans/gauche ratio is considerably affected by the transition from the bulk solvent to the surface. Reactive flux correlation function calculations of the reaction rate reveal that deviation from the transition-state theory due to barrier recrossing is greater at the surface than in the bulk water. This suggests that the system exhibits non-Rice-Ramsperger-Kassel-Marcus behavior due to the weak solvent-solute coupling at the water liquid-vapor interface.

Benjamin, Ilan↗

Numerical Study of the Transient Vaporization of an Oxygen Droplet at Sub- and Super-Critical Conditions

Unsteady vaporization of a droplet in a high-pressure quiescent environment has been studied. With spherical symmetry and constant pressure, the process is diffusion controlled. At low pressures droplet heating is significant for most of the droplet lifetime, and an unsteady analysis of the gas phase is required. Then, the vaporization of a liquid oxygen droplet in gaseous hydrogen at moderate and high pressures is considered. At super-critical pressures, the surface temperature reaches the computed critical mixture value where a model for super-critical combustion is needed. The details of the diffusion layer of dissolved hydrogen do not significantly affect the results. Various methods are explored to compute the gas-phase density. Under the model's assumptions, homogeneous nucleation is not likely to occur.

Delplanque, J.-P.↗

Ground-based microwave remote sensing of water vapor in the mesosphere and stratosphere

A ground-based, portable microwave radiometer that will be used to measure water vapor in the 30-80-km altitude region, and is to operate 24 hr a day, is described. The thermally excited 22.235-GHz rotational-transition line of water vapor is employed. The emission from this region produces a signal with an apparent brightness temperature of the order 0.1 to 0.5 K. A steerable reflector is used to provide optimal viewing angles, depending on the geographic location and season. Periodic tipping curve scans by this reflector permit determination of the amount of tropospheric correction that is applied to the data. All local oscillators in the receiver are crystal-controlled so that narrow-band spectral analysis of the received line shape can be performed.

Croskey, Charles L.↗

Intercomparison of stratospheric water vapor observed by satellite experiments - Stratospheric Aerosol and Gas Experiment II versus Limb Infrared Monitor of the Stratosphere and Atmospheric Trace Molecule Spectroscopy

A comparison is made of the stratospheric water vapor measurements made by the satellite sensors of the Stratospheric Aerosol and Gas Experiment II (SAGE II), the Nimbus-7 LIMS, and the Spacelab 3 Atmospheric Trace Molecule Spectroscopy (ATMOS) experiment. It was found that, despite differences in the measurement techniques, sampling bias, and observational periods, the three experiments have disclosed a generally consistent pattern of stratospheric water vapor distribution. The only significant difference occurs at high southern altitudes in May below 18 km, where LIMS measurements were 2-3 ppmv greater than those of SAGE II and ATMOS.

Chiou, E. W.↗

Comparison of Stratospheric Aerosol and Gas Experiment II and balloon-borne stratospheric water vapor measurements

The Stratospheric Aerosol and Gas Experiment II has one channel at 940 nm related to water vapor. Two inversion procedures were developed independently in order to obtain the water vapor profile: the Chahine method by the Langley Research Center, and the Mill method by the Laboratoire d'Optique Atmospherique. Comparisons were made between these two algorithms and some results are presented at midlatitudes (about 45 deg N) and tropical latitudes (12-25 deg S). They are compared with in situ frost point hygrometer data provided by balloon experiments from the Laboratoire de Meteorologie Dynamique. At +/- 0.5 ppmv, agreement between the inversion results and the experimental results was obtained in the altitude range from 18-19 to 26-27 km. Below 18-19 km and above 26-27 km the error is larger (sometimes 1 ppmv and more).

Pruvost, P.↗

Growth of thin films of organic nonlinear optical materials by vapor growth processes - An overview and examination of shortfalls

Research on the growth of second- and third-order nonlinear optical (NLO) organic thin film by vapor deposition is reviewed. Particular attention is given to the experimental methods for growing thin films of p-chlorophenylurea, diacetylenes, and phthalocyanines; characteristics of the resulting films; and approaches for advancing thin film technology. It is concluded that the growth of NLO thin films by vapor processes is a promising method for the fabrication of planar waveguides for nonlinear optical devices. Two innovative approaches are proposed including a method of controlling the input beam frequency to maximize nonlinear effects in thin films and single crystals, and the alternate approach to the molecular design of organic NLO materials by increasing the transition dipole moment between ground and excited states of the molecule.

Frazier, D. O.↗

Absorption coefficients for water vapor at 193 nm from 300 to 1073 K

Measurements of the water absorption coefficient at 193 nm from 300 to 1073 K are reported. The measurements were made using broadband VUV radiation and a monochromator-based detection system. The water vapor was generated by a saturator and metered into a flowing, 99 cm absorption cell via a water vapor mass flow meter. The 193 nm absorption coefficient measurements are compared to room temperature and high temperature shock tube measurements with good agreement. The absorption can be parameterized by a nu3 vibrational mode reaction coordinate and the thermal population of the nu3 mode.

Kessler, W. J.↗

Millimeter-wave imaging radiometer for cloud, precipitation and atmospheric water vapor studies

A millimeter-wave imaging radiometer (MIR) developed by NASA Goddard Space Flight Center is described. The MIR is a nine-channel total power radiometer developed for atmospheric research. Three dual-pass band channels are centered about the strongly opaque 183-GHz water vapor absorption line; the frequencies are 183 +/- 1, +/- 3, and +/- 7 GHz. Another channel is located on the wing of this band at 150 GHz. These four channels have varying degrees of opacity from which the water vapor profile can be inferred. The design and salient characteristics of this instrument are discussed, together with its expected benefits.

Racette, P. E.↗

Effects of detailed droplet heating models on turbulent sprays vaporization behavior

The effects of three different droplet heating models on the vaporization history and internal structure of turbulent liquid fuel sprays were investigated. The models considered were the infinite-diffusion, diffusion-limit, and effective-conductivity models. A numerical solution for the models was developed and implemented in the KIVA-II computer code. Low temperature and relatively high temperature numerical studies were conducted. The low temperature computations were compared with existing experimental data. The comparisons showed that while the infinite-diffusion and diffusion-limit models respectively overpredicted and underpredicted the fuel vapor peak concentration and distribution in the combustor, the effective-conductivity model gave results that were in better agreement with measurements. A limited study for the high temperature case was performed due to lack of experimental data and predictions using the three models were compared with each other.

Mawid, M. A.↗

One-parameter scaling and exponential-sum fitting for water vapor and CO2 infrared transmission functions

A medium-sized band model for water vapor and CO2 absorption is developed using the one-parameter scaling approximation. The infrared spectrum is divided into 10 bands. The Planck-weighted diffuse transmittance is reduced to a function dependent only upon the scaled absorber amount and fit by an exponential sum. By selecting specific sets of absorption coefficients for exponential-sum fitting, computations of fluxes and cooling rate are made very fast. Compared to a broadband model, the accuracy, speed, and versatility are all enhanced. With absorption due to water vapor line, continuum, CO2 as well as O3 included, the parameterization introduces an error of less than 1.5 W/sq m in fluxes and less than 0.15 C/day in the tropospheric and lower stratospheric cooling rates.

Chou, Ming-Dah↗

A comparison of observed (HALOE) and modeled (CCM2) methane and stratospheric water vapor

Recent measurements (21 September-15 October 1992) of methane and water vapor by the Halogen Occultation Experiment (HALOE) on the Upper Atmosphere Research Satellite (UARS) are compared with model results for the same season from a troposphere-middle atmosphere version of the National Center for Atmospheric Research (NCAR) Community Climate Model (CCM2). Several important features of the two constituent fields are well reproduced by the CCM2, despite the use of simplified methane photochemistry in the CCM2 and some notable differences between the model's zonal mean circulation and climatology. Observed features simulated by the model include the following: 1) subsidence over a deep layer in the Southern Hemisphere polar vortex; 2) widespread dehydration in the polar vortex; and 3) existence of a region of low water vapor mixing ratios extending from the Antarctic into the Northern Hemisphere tropics, which suggests that Antarctic dehydration contributes to midlatitude and tropical dryness in the stratosphere.

Mote, Philip W.↗

Chemical vapor deposition coatings for oxidation protection of titanium alloys

Results of an experimental investigation of the oxidation protection afforded to Ti-14Al-21Nb and Ti-14Al-23Nb-2V titanium aluminides and Ti-17Mo-3Al-3Nb titanium alloy by aluminum-boron-silicon and boron-silicon coatings are presented. These coatings are applied by a combination of physical vapor deposition (PVD) and chemical vapor deposition (CVD) processes. The former is for the application of aluminum, and the latter is for codeposition of boron and silicon. Coating thickness is in the range of 2 to 7 microns, and coating weights are 0.6 to 2.0 mg/sq cm. Oxidation testing was performed in air at temperatures to 1255 K in both static and hypersonic flow environments. The degree of oxidation protection provided by the coatings is determined from weight change measurements made during the testing and post test compositional analyses. Temperature-dependent total normal emittance data are also presented for four coating/substrate combinations. Both types of coatings provided excellent oxidation protection for the exposure conditions of this investigation. Total normal emittances were greater than 0.80 in all cases.

Cunnington, G. R.↗

Preliminary Tests on the Vaporization of Fuel Sprays

High-speed motion pictures were taken of fuel sprays injected into the combustion chamber of the N.A.C.A. combustion apparatus. Three fuels, ethyl alcohol, gasoline, and fuel oil, which differed considerably in volatility were tested. By maintaining the engine temperature below that required for ignition the spray could be studied from soon after the start of injection until 130 crank degrees later. The results show that the sprays vaporize appreciably so that it is possible for the ignition in high speed compression-ignition engines to take place from the vapor phase.

Rothrock, A M↗

Performance of a single fuel-vaporizing combustor with six injectors adapted for gaseous hydrogen

The combustor was operated over a range of inlet-air pressures from 5.3 to 24.0 inches of mercury absolute and inlet-air reference velocities from 60 to 100 feet per second. The combustion efficiencies obtained with the six configurations varied from about 65 to 95 percent for a combustor temperature-rise range of 200 degrees to 1400 degrees F. At a temperature rise of 1200 degrees F (near-rated engine conditions), the spread in efficiencies of the six configurations was about 5 percent. Efficiencies in the range of 65 to 85 percent were obtained at operating conditions beyond the burning range of conventional jet fuels. A fuel-injector configuration that fed only gaseous hydrogen fuel into the standard liquid-fuel-vaporizing tubes generally gave the highest efficiencies. This configuration minimizes the possibility of combustion in the fuel-vaporizing tubes and could be easily adapted to the full-scale engine combustor.

Wear, Jerrold D↗