Recent Diagnostic Platform Accomplishments for Studying Vacuum Power Flow Physics at the Sandia Z Accelerator.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Scientists, engineers and programmers at Fermilab are tackling today’s most challenging computational problems. Their solutions, motivated by the needs of worldwide research in particle physics and accelerators, help America stay at the forefront of innovation.
Machine learning (ML) has emerged as a tool for understanding data at scale. However, this new methodology comes at a cost because ML requires the use of even more HPC resources to generate ML algorithms. In addition to the compute resources required to develop ML algorithms, ML does not sidestep one of the biggest challenges on leading-edge HPC systems: the increasing gap between compute performance and I/O bandwidth. This has led to a strong push towards in situ, processing the data as it is generated, strategies to mitigate the I/O bottleneck. Unfortunately, there are no in situ frameworks dedicated to coupling scientific visualization and ML at scale to develop ML algorithms for scientific visualization. To address the ML and in situ visualization gap, we introduce PAVE. PAVE is an in situ framework which addresses the data management needs between visualisation and machine learning tasks. We demonstrate our framework with a case study that accelerates physically-based light rendering, path-tracing, through the use of a conditional Generative Adversarial neural Network (cGAN). PAVE couples the training over path-traced images resulting in a generative model able to produce scene renderings with accurate light transport and global illumination of a quality comparable to offline approaches in a more efficient manner.
Explore the source record for details and available documents.
A framework for high level accelerator application software is being developed for the Linac Coherent Light Source (LCLS). The framework is based on plug-in technology developed by an open source project, Eclipse. Many existing functionalities provided by Eclipse are available to high-level applications written within this framework. The framework also contains static data storage configuration and dynamic data connectivity. Because the framework is Eclipse-based, it is highly compatible with any other Eclipse plug-ins. The entire infrastructure of the software framework will be presented. Planned applications and plug-ins based on the framework are also presented.
Neutron capture cross sections on unstable nuclei are important for many applications in nuclear structure and astrophysics. Measuring these cross sections directly is a major challenge and often impossible. An indirect approach for measuring these cross sections is the surrogate reaction method, which makes it possible to relate the desired cross section to a cross section of an alternate reaction that proceeds through the same compound nucleus. To benchmark the validity of using the (d,p{gamma}) reaction as a surrogate for (n,{gamma}), the {sup 171,173}Yb(d,p{gamma}) reactions were measured with the goal to reproduce the known [1] neutron capture cross section ratios of these nuclei.
A recent theory of transverse centroid oscillations in solenoidally focused beam transport lattices presented in Ref. [1] is applied to statistically analyze properties of the centroid orbit in the Neutralized Drift Compression Experiment (NDCX) at the Lawrence Berkeley National Laboratory. Contributions to the amplitude of the centroid oscillations from mechanical misalignments and initial centroid errors exiting the injector are analyzed. Measured values of the centroid appear consistent with expected alignment tolerances. Correction of these errors is discussed.
The DA{Phi}NE collider has been recently upgraded in order to implement a new collision scheme based on large Piwinski angle and cancellation of the synchro-betatron resonances by means of electromagnetic sextupoles (Crab-Waist compensation). The novel approach has proved to be effective in improving beam-beam interaction and collider luminosity. The results and the measurements taken during commissioning as well as the perspectives for the SIDDHARTA run are presented and discussed.
The United States of America currently relies on foreign suppliers to meet all of it needs for molybdenum-99 (Mo-99) used in medical diagnostic procedures. The current US demand is at least 5000 six-day curies per week. Neutronics calculations have been performed to assess whether the proposed Materials Test Station (MTS) could potentially generate Mo-99. Two target material options have been explored for Mo-99 production in the MTS: low enriched uranium (LEU) and Tc-99. For LEU, scoping calculations indicate that MTS can supply nearly half of the current US demand with only minor neutronic impact on the MTS primary mission. For the Tc-99 option, the MTS could produce about one-tenth of the US demand.
This work measures and compares the energy spectra of four dosimetrically matched 6 MV beams, generated from four physically different linear accelerators. The goal of this work is twofold. First, this study determines whether the spectra of dosimetrically matched beams are measurably different. This study also demonstrates that the spectra of clinical photon beams can be measured as a part of the beam data collection process for input to a three-dimensional (3D) treatment planning system. The spectra of 6 MV beams that are dosimetrically matched for clinical use were studied to determine if the beam spectra are similarly matched. Each of the four accelerators examined had a standing waveguide, but with different physical designs. The four accelerators were two Varian 2100C/Ds (one 6 MV/18 MV waveguide and one 6 MV/10 MV waveguide), one Varian 600 C with a vertically mounted waveguide and no bending magnet, and one Siemens MD 6740 with a 6 MV/10 MV waveguide. All four accelerators had percent depth dose curves for the 6 MV beam that were matched within 1.3%. Beam spectra were determined from narrow beam transmission measurements through successive thicknesses of pure aluminum along the central axis of the accelerator, made with a graphite Farmer ion chamber with a Lucite buildup cap. An iterative nonlinear fit using a Marquardt algorithm was used to find each spectrum. Reconstructed spectra show that all four beams have similar energy distributions with only subtle differences, despite the differences in accelerator design. The measured spectra of different 6 MV beams are similar regardless of accelerator design. The measured spectra show excellent agreement with those found by the auto-modeling algorithm in a commercial 3D treatment planning system that uses a convolution dose calculation algorithm. Thus, beam spectra can be acquired in a clinical setting at the time of commissioning as a part of the routine beam data collection.
This thesis covers work performed for the Accelerator Neutrino Neutron Interaction Experiment (ANNIE) between 2015 and 2020. ANNIE is a beamline neutrino experiment located at the Fermi National Accelerator Laboratory in Chicago. Its primary physics goals are the measurement of neutrino interaction cross-sections on oxygen, and a measurement of the multiplicity of final state neutrons from these interactions, both as functions of final state kinematics. In order to achieve these goals ANNIE will be pioneering the use of Large Area Picosecond Photodetectors and the use of gadolinium doping to enhance neutron visibility in a water Cherenkov detector. Over the time period of this thesis the ANNIE detector was constructed, an initial 'Phase I' background run was completed, the detector was decommissioned and then substantially upgraded in preparation for the main 'Phase II' physics run. At the time of writing ANNIE is being re-commissioned, with Phase II data taking anticipated to begin in 2021. During this time I spent 21/2 years on-site contributing to almost all aspects of hardware work, while performing software development for the simulation and analysis frameworks. As my first software task I developed Monte Carlo simulations of the detector response, based on the WCSim framework. While thismore » framework provided a starting point for the tank simulation significant modifications were required to implement the complete ANNIE detector system. This included a rewrite of the geometry, along with modifications to the photosensor definitions, hit collections, digitization, triggering, input and output interfaces, etc. To take advantage of improved modelling of neutrons in Geant4.10 the physics lists were also reimplemented in the new version format. As part of this work I determined performance metrics based on the output files, calculating kinematic acceptance, detector efficiency and expected event rates. My contributions on reconstruction focused primarily on the MRD, for which I implemented two track reconstruction algorithms, specialised for high and low energy muons. The high energy algorithm achieves >90% efficiency for tracks with at least 8 hits, and is robust against dead paddles and unrelated hits. The low energy algorithm performs a search in combination with tank information to provide sensitivity down to a single MRD hit. Early data handling work for the Phase I background run included writing the code for handling TDC hits and performing studies on neutron detection without the requirement of multi-hit coincidence. As the collaboration moved to a new framework for the Phase II analysis I performed a substantial amount of work to develop the codebase, implementing tools to perform tasks such as file IO, data parsing, waveform processing, event building, timestamp alignment, time clustering, hit residual calculation, event visualisation etc. I helped develop the python API for integrating multi-language tools, and ported the framework into a Singularity container to provide a self-contained environment that…« less
The pverarching purpose is to accelerate and expand the scope of discoveries from high energy physics (HEP) particle accelerators by enabling the design of accelerators that are significantly more compact and cheaper to build and run. This will be realized through (i) developing high-performance computing (HPC) accelerator and beam modeling capabilities to design the full range of systems required (ii) developing community simulation ecosystems that seamlessly integrate accelerator elements to facilitate the design and control of next-generation accelerators.
The MESA accelerator will operate for particle and nuclear physics experiments in two different modes. A first option is conventional c.w. acceleration yielding 150-200MeV spin-polarized external beam. Second, MESA will be operated as a superconducting multi-turn energy recovery linac (ERL), opening the opportunity to perform experiments with a windowless target with beam current of up to 10 mA. The perspectives for innovative experiments with such a machine are discussed together with a sketch of the accelerator physics issues that have to be solved.
GANIL presently offers unique opportunities in nuclear physics and many other fields that arise from not only the provision of low-energy stable beams, fragmentation beams and re-accelerated radioactive species, but also from the availability of a wide range of state-of-the-art spectrometers and instrumentation. A few examples of recent highlights are presented.With the construction of SPIRAL2 over the next few years, GANIL is in a good position to retain its world-leading capability. As selected by the ESFRI committee, the next generation of ISOL facility in Europe is represented by the SPIRAL2 project to be built at GANIL (Caen, France). SPIRAL 2 is based on a high power, CW, superconducting LINAC, delivering 5 mA of deuteron beams at 40 MeV (200 KW) directed on a C converter+ Uranium target and producing therefore more 10{sup 13} fissions/s. The expected radioactive beams intensities in the mass range from A = 60 to A = 140, will surpass by two order of magnitude any existing facilities in the world. These unstable atoms will be available at energies between few KeV/n to 15 MeV/n. The same driver will accelerate high intensity (100*A to 1 mA), heavier ions (Ar up to Xe) at maximum energy of 14 MeV/n.Under the 7FP program of European Union called*Preparatory phase*, the SPIRAL2 project has been granted a budget of about 4 MEuro to build up an international consortium around this new venture. The status of the construction of SPIRAL2 accelerator and associated physics instruments in collaboration with EU and International partners will be presented.
GANIL presently offers unique opportunities in nuclear physics and many other fields that arise from not only the provision of low-energy stable beams, fragmentation beams and re-accelerated radioactive species, but also from the availability of a wide range of state-of-the-art spectrometers and instrumentation. A few examples of recent highlights are discussed in the present paper.With the construction of SPIRAL2 over the next few years, GANIL is in a good position to retain its world-leading capability. As selected by the ESFRI committee, the next generation of ISOL facility in Europe is represented by the SPIRAL2 project to be built at GANIL (Caen, France). SPIRAL 2 is based on a high power, CW, superconducting LINAC, delivering 5 mA of deuteron beams at 40 MeV (200 KW) directed on a C converter+ Uranium target and producing therefore more than 10{sup 13} fissions/s. The expected radioactive beam intensities in the mass range from A = 60 to A = 140, will surpass by two orders of magnitude any existing facilities in the world. These unstable atoms will be available at energies between few KeV/n to 15 MeV/n. The same driver will accelerate high intensity (100 {mu}A to 1 mA), heavier ions (Ar up to Xe) at maximum energy of 14 MeV/n. Under the 7FP program of European Union called *Preparatory phase*, the SPIRAL2 project has been granted a budget of about 4MEuro to build up an international consortium around this new venture. The status of the construction of SPIRAL2 accelerator and associated physics instruments in collaboration with EU and International partners will be presented.
Physical parameters relevant to the acceleration and propagation of energetic electrons during the impulsive phase of a solar flare are studied in hard X-ray, microwave and both type III and decimetric radio bursts associated with the December 4, 1978 solar flare. A one-to-one association between single type III bursts and hard X-ray peaks is established, along with a burst delay with respect to the peaks of 0.5 sec. The observed increase of the high frequency cutoff of the metric type III bursts during the impulsive phase is examined in terms of the decreasing altitude of the electron acceleration/injection region, increasing electron spectrum hardness, and decreasing acceleration time. A pulsating decimetric continuum was found to be present during and before the impulsive phase whose high frequency cutoff also systematically increased during the rise of the impulsive phase.
The CMB temperature power spectrum offers ambiguous evidence for the existence of horizon-scale power in the primordial power spectrum due to uncertainties in spatial curvature and the physics of cosmic acceleration as well as the observed low quadrupole. Current polarization data from WMAP provide evidence for horizon-scale power that is robust to these uncertainties. Polarization on the largest scales arises mainly from scattering at z < or approx. 6 when the Universe is fully ionized, making the evidence robust to ionization history variations at higher redshifts as well. A cutoff in the power spectrum is limited to C=k{sub C}/10{sup -4} Mpc{sup -1}<5.2 (95% C.L.) by polarization, only slightly weaker than joint temperature and polarization constraints in flat {lambda}CDM (C<4.2). Planck should improve the polarization limit to C<3.6 for any model of the acceleration epoch and ionization history as well as provide tests for foreground and systematic contamination.