Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Design and Performance of the Antenna-Coupled Lumped-Element Kinetic Inductance Detector

Focal plane arrays consisting of low-noise, polarisation-sensitive detectors have made possible the pioneering advances in the study of the cosmic microwave background (CMB). To make further progress, the next generation of CMB experiments (e.g. CMB-S4) will require a substantial increase in the number of detectors compared to current instruments. Arrays of kinetic inductance detectors (KIDs) provide a possible path to realising such large-format arrays owing to their intrinsic multiplexing advantage and relative cryogenic simplicity. In this paper, we report on the design of a variant of the traditional KID design: the antenna-coupled lumped-element KID. A polarisation-sensitive twin-slot antenna placed behind an optimised hemispherical lens couples power onto a thin-film superconducting microstrip line. The power is then guided into the inductive section of an aluminium KID, where it is absorbed and modifies both the resonant frequency and quality factor of the KID. We present the various aspects of the design and preliminary results from the first set of seven-element prototype arrays and compare to the expected modelled performance.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Efficient scalable solid-state neutron detector

We report on scalable solid-state neutron detector system that is specifically designed to yield high thermal neutron detection sensitivity. The basic detector unit in this system is made of a {sup 6}Li foil coupled to two crystalline silicon diodes. The theoretical intrinsic efficiency of a detector-unit is 23.8% and that of detector element comprising a stack of five detector-units is 60%. Based on the measured performance of this detector-unit, the performance of a detector system comprising a planar array of detector elements, scaled to encompass effective area of 0.43 m{sup 2}, is estimated to yield the minimum absolute efficiency required of radiological portal monitors used in homeland security.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-energy x-ray detector calibration for T e and impurity density (n Z ) measurements of MCF plasmas

Here, soft x-ray detection with the new "multi-energy" PILATUS3 detector systems holds promise as a magnetically confined fusion (MCF) plasma diagnostic for ITER and beyond. The measured x-ray brightness can be used to determine impurity concentrations, electron temperatures, n 2 e Z eff products, and to probe the electron energy distribution. However, in order to be effective, these detectors which are really large arrays of detectors with photon energy gating capabilities must be precisely calibrated for each pixel. The energy-dependence of the detector response of the multi-energy PILATUS3 system with 100 K pixels has been measured at Dectris Laboratory. X-rays emitted from a tube under high voltage bombard various elements such that they emit x-ray lines from Zr-Lα to Ag-Kα between 1.8 and 22.16 keV. Each pixel on the PILATUS3 can be set to a minimum energy threshold in the range from 1.6 to 25 keV. This feature allows a single detector to be sensitive to a variety of x-ray energies, so that it is possible to sample the energy distribution of the x-ray continuum and line-emission. PILATUS3 can be configured for 1D or 2D imaging of MCF plasmas with typical spatial energy and temporal resolution of 1 cm, 0.6 keV, and 5 ms, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hyperspectral Infrared Images of Terrain

Images at 128 wavelengths allow direct identification of many earth surface materials. Two reports describe advanced airborne spectrometer that creates images of terrain at many wavelengths. Airborne imaging spectrometer (AIS) produces two-dimensional images in 128 spectral bands in 1.2-to-2.4-micrometer wavelength region. Images created by 32-by-32 array of mercury cadmium telluride detector elements. Array views swath of Earth below moving aircraft. Used for agricultural, geological, and other surveys.

Vane, G.↗

Array Technology for Terahertz Imaging

Heterodyne terahertz (0.3 - 3THz) imaging systems are currently limited to single or a low number of pixels. Drastic improvements in imaging sensitivity and speed can be achieved by replacing single pixel systems with an array of detectors. This paper presents an array topology that is being developed at the Jet Propulsion Laboratory based on the micromachining of silicon. This technique fabricates the array's package and waveguide components by plasma etching of silicon, resulting in devices with precision surpassing that of current metal machining techniques. Using silicon increases the versatility of the packaging, enabling a variety of orientations of circuitry within the device which increases circuit density and design options. The design of a two-pixel transceiver utilizing a stacked architecture is presented that achieves a pixel spacing of 10mm. By only allowing coupling from the top and bottom of the package the design can readily be arrayed in two dimensions with a spacing of 10mm x 18mm.

Terahertz↗

All-epitaxial resonant cavity enhanced long-wave infrared detectors for focal plane arrays

Here, we demonstrate a monolithic all-epitaxial resonant-cavity architecture for long-wave infrared photodetectors with substrate-side illumination. An nBn detector with an ultra-thin (t ≈ 350 nm) absorber layer is integrated into a leaky resonant cavity, formed using semitransparent highly doped (n⁺⁺) epitaxial layers, and aligned to the anti-node of the cavity’s standing wave. The devices are characterized electrically and optically and demonstrate an external quantum efficiency of 25% at T ¼ 180 K in an architecture compatible with focal plane array configurations.

42 ENGINEERING↗

Characterization of the CATRiNA neutron detector system

The Compound Array for Transfer Reactions in Nuclear Astrophysics (CATRiNA) is a neutron detector system which has been developed at Florida State University to measure neutrons from nuclear reactions aimed to help in the understanding of the structure of the atomic nucleus, the way nuclei interact among each other, and their impact in astrophysical processes. Detecting neutrons is difficult due to their lack of charge. CATRiNA is a novel neutron detector system which consists of 16 liquid scintillator detectors with deuterium (2H) as the interaction material. This paper describes the development and characterization of the CATRiNA detector array using neutron and gamma-ray sources, Monte-Carlo simulations, and neutrons with defined energy from the 7Li(p,n) nuclear reaction. CATRiNA is ready to be used in nuclear physics experimental research.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessment of a 1-D, Multi-colour X-ray Imaging System for the MAST ST

A design of the ID soft x-ray imaging system for future experiments at the Mega-Amper Spherical Tokamak (MAST) and results of the numerical simulations based on initial assumptions about the state of the tokamak plasma as well as the parameters and geometry of the detection system are presented. The imaging system consists of a set of arrays of detectors, pinholes and filters attached to each set, together with suitable readout electronics. In simulations, an array of semiconductor detectors is compared with an array of scintillator-photomultiplier combination. The measuring system is assumed to operate in the range 1-10 keV. In addition to the 1-D imaging of x-ray emission, the system gives the possibility to measure the energy slope of x-ray spectrum and thus the electron temperature of plasma.An extended numerical code simulates the imaging system for various parameters of plasma (spatial profiles of the plasma density and temperature) generated at the tokamak and for different configurations of the detection system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Mosaic-Detector-Based Fluorescence Spectral Imager

A battery-powered, pen-sized, portable instrument for measuring molecular fluorescence spectra of chemical and biological samples in the field has been proposed. Molecular fluorescence spectroscopy is among the techniques used most frequently in laboratories to analyze compositions of chemical and biological samples. Heretofore, it has been possible to measure fluorescence spectra of molecular species at relative concentrations as low as parts per billion (ppb), with a few nm spectral resolution. The proposed instrument would include a planar array (mosaic) of detectors, onto which a fluorescence spectrum would be spatially mapped. Unlike in the larger laboratory-type molecular fluorescence spectrometers, mapping of wavelengths to spatial positions would be accomplished without use of relatively bulky optical parts. The proposed instrument is expected to be sensitive enough to enable measurement of spectra of chemical species at relative concentrations <1 ppb, with spectral resolution that could be tailored by design to be comparable to a laboratory molecular fluorescence spectrometer. The proposed instrument (see figure) would include a button-cell battery and a laser diode, which would generate the monochromatic ultraviolet light needed to excite fluorescence in a sample. The sample would be held in a cell bounded by far-ultraviolet-transparent quartz or optical glass. The detector array would be, more specifically, a complementary metal oxide/ semiconductor or charge-coupled- device imaging photodetector array, the photodetectors of which would be tailored to respond to light in the wavelength range of the fluorescence spectrum to be measured. The light-input face of the photodetector array would be covered with a matching checkerboard array of multilayer thin film interference filters, such that each pixel in the array would be sensitive only to light in a spectral band narrow enough so as not to overlap significantly with the band of an adjacent pixel. The wavelength interval between adjacent pixels (and, thus, the spectral resolution) would typically be chosen by design to be approximately equal to the width of the total fluorescence wavelength range of interest divided by the number of pixels. The unitary structure comprising the photodetector array overlaid with the matching filter array would be denoted a hyperspectral mosaic detector (HMD) array.

Son, Kyung-Ah↗

Development of an array of liquid-scintillator-based bar detectors: SABRE

We present that an array of neutron detectors based on liquid scintillator technology has been developed for nuclear reaction studies, in particular measurements with radioactive ion beams (RIBs). Reaction measurements with RIBs often involve low reaction yields and high gamma-induced backgrounds, which requires high solid angle coverage, high efficiency, and background reduction capability. The kinematics of the reaction neutrons require energy and position determination with good resolution, but preferably without a large number of readouts to minimize cost. To address these requirements, the Scintillation Array of Bars for Reaction Experiments (SABRE) consists of five 12” long, 2” diameter bar detectors filled with organic liquid scintillator and capped at both ends with individually read-out superbialkali photomultiplier tubes (PMTs). Finally, in-house purification of the scintillator mixtures resulted in improved light collection. Discussion of the liquid scintillator development and the design and commissioning of SABRE will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SRAM As An Array Of Energetic-Ion Detectors

Static random-access memory (SRAM) designed for use as array of energetic-ion detectors. Exploits well-known tendency of incident energetic ions to cause bit flips in cells of electronic memories. Design of ion-detector SRAM involves modifications of standard SRAM design to increase sensitivity to ions. Device fabricated by use of conventional complementary metal oxide/semiconductor (CMOS) processes. Potential uses include gas densimetry, position sensing, and measurement of cosmic-ray spectrum.

Buehler, Martin G.↗

High resolution spectroscopy from low altitude satellites

The P 78 1 satellite to be placed in a synchronous polar orbit at an altitude of 550-660 km will carry two identical high resolution spectrometers each consisting of a single (approximately 85 cc) intrinsic germanium IGE detector. The payload also includes a pair of phoswitch scintillators, an array of CdTe detectors and several particle detectors, all of which are mounted on the wheel of the satellite. The intrinsic high purity IGE detectors receive cooling from two Stirling cycle refrigerators and facilitate the assembly of large and complex detector arrays planned for the next generation of high sensitivity instruments such as those planned for the gamma ray observatory. The major subsystems of the spectrometer are discussed as well as its capabilities.

Nakano, G. H.↗

Characterization of a novel two dimensional diode array the ''magic plate'' as a radiation detector for radiation therapy treatment

Purpose: Intensity modulated radiation therapy (IMRT) utilizes the technology of multileaf collimators to deliver highly modulated and complex radiation treatment. Dosimetric verification of the IMRT treatment requires the verification of the delivered dose distribution. Two dimensional ion chamber or diode arrays are gaining popularity as a dosimeter of choice due to their real time feedback compared to film dosimetry. This paper describes the characterization of a novel 2D diode array, which has been named the ''magic plate'' (MP). It was designed to function as a 2D transmission detector as well as a planar detector for dose distribution measurements in a solid water phantom for the dosimetric verification of IMRT treatment delivery. Methods: The prototype MP is an 11 x 11 detector array based on thin (50 {mu}m) epitaxial diode technology mounted on a 0.6 mm thick Kapton substrate using a proprietary ''drop-in'' technology developed by the Centre for Medical Radiation Physics, University of Wollongong. A full characterization of the detector was performed, including radiation damage study, dose per pulse effect, percent depth dose comparison with CC13 ion chamber and build up characteristics with a parallel plane ion chamber measurements, dose linearity, energy response and angular response. Results: Postirradiated magic plate diodes showed a reproducibility of 2.1%. The MP dose per pulse response decreased at higher dose rates while at lower dose rates the MP appears to be dose rate independent. The depth dose measurement of the MP agrees with ion chamber depth dose measurements to within 0.7% while dose linearity was excellent. MP showed angular response dependency due to the anisotropy of the silicon diode with the maximum variation in angular response of 10.8% at gantry angle 180 deg. Angular dependence was within 3.5% for the gantry angles {+-} 75 deg. The field size dependence of the MP at isocenter agrees with ion chamber measurement to within 1.1%. In the beam perturbation study, the surface dose increased by 12.1% for a 30 x 30 cm{sup 2} field size at the source to detector distance (SDD) of 80 cm whilst the transmission for the MP was 99%. Conclusions: The radiation response of the magic plate was successfully characterized. The array of epitaxial silicon based detectors with ''drop-in'' packaging showed properties suitable to be used as a simplified multipurpose and nonperturbing 2D radiation detector for radiation therapy dosimetric verification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrating 128 element InSb array - Recent results

There has been a continuing evolution toward larger arrays of infrared detectors, and the technology base derived from the Galileo Near Infrared Mapping Spectrometer (NIMS) has been expanded to linear arrays including from 128 to 512 elements. This advance is based on the commercial availability of high-quality InSb photodiodes and 128/256 element FET switch MUX's (multiplexing elements). The present investigation is concerned with an experimental 128-element linear imager using InSb detectors and silicon MUX for readout. Attention is given to detector array electrical characteristics, the detector readout architecture, noise, and special effects.

Bailey, G.↗

Spatially resolved x-ray detection with photonic crystal scintillators

We study the self-collimation phenomenon in photonic crystals (PhC) of wide bandgap materials for ultra-fast and high spatial resolution x-ray detection. We work on various heavy inorganic scintillators: BaF 2 , GaN, ZnO, CsI:Tl, NaI:Tl, LYSO, WO 4 compounds, and plastic scintillators. Conventional scintillator detectors do not rely on a direct detection mechanism; hence, they require intricate design and fabrication processes. We offer a PhC design to observe self-collimation phenomena and overcome the ongoing spatial resolution challenges with these types of materials. We investigate the photonic band diagrams and iso-frequency contours. Fourier transforms based on finite-difference time-domain and frequency domain simulations are done for verifying and analyzing the self-collimation with the selected material. Light extraction efficiency at the PhC–air interface, depending on the truncation distance from the excitation point, is measured. Beam divergence values are calculated at 1 mm propagation distance. The vertical field profiles are obtained to observe the confinement. For the spatial resolution analysis, cross-sectional beam profiles have been examined. Furthermore, Gaussian envelopes are fitted to beam profiles for a consistent data analysis, and full-width-at-half-maximum values are considered. As a result, we theoretically prove and demonstrate the spatially resolved x-ray detection at the sub-micrometer level for a wide range of scintillator materials.

36 MATERIALS SCIENCE↗

Cosmic ray experimental observations

The current experimental situation in cosmic ray studies is discussed, with special emphasis on the development of new detector systems. Topics covered are the techniques for particle identification, energy measurements, gas Cerenkov counters, magnet spectrometers, ionization spectrometers, track detectors, nuclear emulsions, multiparameter analysis using arrays of detectors, the Goddard ionization spectrometer, charge spectra, relative abundances, isotope composition, antinuclei in cosmic rays, electrons, the measurement of cosmic ray arrival directions, and the prehistory of cosmic rays.

Balasubrahmanyan, V. K.↗

MOLA II Laser Transmitter Calibration and Performance

The goal of the document is to explain the algorithm for determining the laser output energy from the telemetry data within the return packets from MOLA II. A simple algorithm is developed to convert the raw start detector data into laser energy, measured in millijoules. This conversion is dependent on three variables, start detector counts, array heat sink temperature and start detector temperature. All these values are contained within the return packets. The conversion is applied to the GSFC Thermal Vacuum data as well as the in-space data to date and shows good correlation.

Afzal, Robert S.↗