Search NASA⌕ Search

SEARCH · Search NASA

Results for “diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Erratum: “Multi-point, high-speed passive ion velocity distribution diagnostic on the Pegasus Toroidal Experiment” [Rev. Sci. Instrum. 83, 10D516 (2012)]

This article corrects an error in M.G. Burke et al., 'Multi-point, high-speed passive ion velocity distribution diagnostic on the Pegasus Toroidal Experiment,' Rev. Sci. Instrum. 83, 10D516 (2012) pertaining to ion temperature. The conclusions of this paper are not altered by the revised ion temperature measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic for determining the mix in inertial confinement fusion capsule hotspot

A diagnostic is developed for determining the hotspot mix in inertial confinement fusion experiments. A multi-channel pinhole camera measures Bremsstrahlung emissions from implosion capsules ranging from 6 keV to 30 keV and records an image of the hotspot. Meanwhile, a planar crystal spectrometer measures Ar line emissions used to deduce the electron density of the hotspot. An X-ray streaked camera records the burn duration. With the Bremsstrahlung spectrum, electron density, hotspot volume, and burn duration, the mix quantity is determined by solving a pair of linear equations. This inferred mix amount has an uncertainty due to the uncertainty of the electron density, but with the help of the measured neutron product, the most likely mix quantity value can be determined. This technique is applied to experimental images to infer the quantity of CH ablator mix into the hotspot.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast imaging diagnostics on the C-2U advanced beam-driven field-reversed configuration device

The C-2U device employed neutral beam injection, end-biasing, and various particle fueling techniques to sustain a Field-Reversed Configuration (FRC) plasma. As part of the diagnostic suite, two fast imaging instruments with radial and nearly axial plasma views were developed using a common camera platform. To achieve the necessary viewing geometry, imaging lenses were mounted behind re-entrant viewports attached to welded bellows. During gettering, the vacuum optics were retracted and isolated behind a gate valve permitting their removal if cleaning was necessary. The axial view incorporated a stainless-steel mirror in a protective cap assembly attached to the vacuum-side of the viewport. For each system, a custom lens-based, high-throughput optical periscope was designed to relay the plasma image about half a meter to a high-speed camera. Each instrument also contained a remote-controlled filter wheel, set between shots to isolate a particular hydrogen or impurity emission line. The design of the camera platform, imaging performance, and sample data for each view is presented.

43 PARTICLE ACCELERATORS↗

Spatial and temporal analysis of DIII-D 3D magnetic diagnostic data

An extensive set of magnetic diagnostics in DIII-D is aimed at measuring non-axisymmetric "3D" features of tokamak plasmas, with typical amplitudes ~10 -3 to 10 -5 of the total magnetic field. We describe hardware and software techniques used at DIII-D to condition the individual signals and analysis to estimate the spatial structure from an ensemble of discrete measurements. Lastly, applications of the analysis include detection of non-rotating MHD instabilities, plasma control, and validation of MHD stability and 3D equilibrium models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of a two-color soft x-ray diagnostic for electron temperature measurement

The two-color soft x-ray (SXR) tomography diagnostic on the Madison Symmetric Torus is capable of making electron temperature measurements via the double-filter technique; however, there has been a 15% systematic discrepancy between the SXR double-filter (SXR{sub DF}) temperature and Thomson scattering (TS) temperature. Here we discuss calibration of the Be filters used in the SXR{sub DF} measurement using empirical measurements of the transmission function versus energy at the BESSY II electron storage ring, electron microprobe analysis of filter contaminants, and measurement of the effective density. The calibration does not account for the TS and SXR{sub DF} discrepancy, and evidence from experiments indicates that this discrepancy is due to physics missing from the SXR{sub DF} analysis rather than instrumentation effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validations of calibration-free measurements of electron temperature using double-pass Thomson scattering diagnostics from theoretical and experimental aspects

This paper evaluates the accuracy of electron temperature measurements and relative transmissivities of double-pass Thomson scattering diagnostics. The electron temperature (T{sub e}) is obtained from the ratio of signals from a double-pass scattering system, then relative transmissivities are calculated from the measured T{sub e} and intensity of the signals. How accurate the values are depends on the electron temperature (T{sub e}) and scattering angle (θ), and therefore the accuracy of the values was evaluated experimentally using the Large Helical Device (LHD) and the Tokyo spherical tokamak-2 (TST-2). Analyzing the data from the TST-2 indicates that a high T{sub e} and a large scattering angle (θ) yield accurate values. Indeed, the errors for scattering angle θ = 135° are approximately half of those for θ = 115°. The method of determining the T{sub e} in a wide T{sub e} range spanning over two orders of magnitude (0.01–1.5 keV) was validated using the experimental results of the LHD and TST-2. A simple method to provide relative transmissivities, which include inputs from collection optics, vacuum window, optical fibers, and polychromators, is also presented. The relative errors were less than approximately 10%. Numerical simulations also indicate that the T{sub e} measurements are valid under harsh radiation conditions. This method to obtain T{sub e} can be considered for the design of Thomson scattering systems where there is high-performance plasma that generates harsh radiation environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Particle X-ray Temporal Diagnostic (PXTD) for studies of kinetic, multi-ion effects, and ion-electron equilibration rates in Inertial Confinement Fusion plasmas at OMEGA (invited)

Here, a Particle X-ray Temporal Diagnostic (PXTD) has been implemented on OMEGA for simultaneous time-resolved measurements of several nuclear products as well as the x-ray continuum produced in High Energy Density Plasmas and Inertial Confinement Fusion implosions. The PXTD removes systematic timing uncertainties typically introduced by using multiple instruments, and it has been used to measure DD, DT, D 3 He, and T 3 He reaction histories and the emission history of the x-ray core continuum with relative timing uncertainties within ±10-20 ps. This enables, for the first time, accurate and simultaneous measurements of the x-ray emission histories, nuclear reaction histories, their time differences, and measurements of T i (t) and T e (t) from which an assessment of multiple-ion-fluid effects, kinetic effects during the shock-burn phase, and ion-electron equilibration rates can be made.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A new method of out-of-focus millimeter wave imaging in fusion plasma diagnostics using Bessel beams

Electron cyclotron emission imaging (ECEI) and microwave imaging reflectometry diagnostics have been employed on a number of magnetic fusion plasma confinement devices. The common approach is based on a Gaussian beam assumption, which generates good spatial resolution (centimeter level). However, the radial focal depth is limited by the poloidal resolution, which is comparable with the Rayleigh length (~150 mm). By contrast, a new Bessel beam approach has been developed and demonstrated to generate much longer focal depth with the property of propagation stability. To test the new approach, the DIII-D tokamak LCP ECEI optics have been re-designed to support a Bessel beam approach based on an axicon lens. The achievable radial coverage can exceed that of the current Gaussian approach by 3×. Finally, the imaging result is discussed in this paper based on the simulation analysis and laboratory testing result.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The single-line-of-sight, time-resolved x-ray imager diagnostic on OMEGA

We present that the single-line-of-sight, time-resolved x-ray imager (SLOS-TRXI) on OMEGA is one of a new generation of fast-gated x-ray cameras comprising an electron pulse-dilation imager and a nanosecond-gated, burst-mode, hybrid complementary metal-oxide semiconductor sensor. SLOS-TRXI images the core of imploded cryogenic deuterium–tritium shells in inertial confinement fusion experiments in the ~4- to 9-keV photon energy range with a pinhole imager onto a photocathode. The diagnostic is mounted on a fixed port almost perpendicular to a 16 channel, framing-camera–based, time-resolved Kirkpatrick–Baez microscope, providing a second time-gated line of sight for hot-spot imaging on OMEGA. SLOS-TRXI achieves ~40-ps temporal resolution and better than 10 μm spatial resolution. Finally, shots with neutron yields of up to 1 × 10 14 were taken without observed neutron-induced background signal. The implosion images from SLOS-TRXI show the evolution of the stagnating core.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Velocity correction for neutron activation diagnostics at the NIF

The velocity distribution of the hotspot in an inertial confinement fusion implosion changes the energy spectra of fusion neutrons emitted from the experiment as a function of viewing angle. These velocity-induced spectral changes affect the response of neutron activation diagnostics (NADs) positioned around the experiment and must be accounted for to correctly extract information about areal density (ρR) asymmetry from the data. Three mechanisms through which average hotspot velocity affects NAD activation are addressed: change in activation cross section due to the Doppler shift of the mean neutron energy, kinematic focusing of neutron fluence, and change in the scattering cross section due to the Doppler shift. Using the hotspot velocity inferred from neutron time-of-flight measurements of D-T and D-D fusion neutrons, the hotspot velocity is shown to account for the observed NAD activation asymmetry in a calibration shot with negligible fuel ρR. Finally, a robust method to evaluate uncertainties in spherical-harmonic fits to the NAD data due to the velocity correction and detector uncertainty is discussed.

47 OTHER INSTRUMENTATION↗

Plasma impurities observed by a pulse height analysis diagnostic during the divertor campaign of the Wendelstein 7-X stellarator

The paper reports on the optimization process of the soft X-ray pulse height analyzer installed on the Wendelstein 7-X (W7-X) stellarator. It is a 3-channel system that records X-ray spectra in the range from 0.6 to 19.6 keV. X-ray spectra, with a temporal and spatial resolution of 100 ms and 2.5 cm (depending on selected slit sizes), respectively, are line integrated along a line-of-sight that crosses near to the plasma center. In the second W7-X operation phase with a carbon test divertor unit, we report light impurities, e.g., carbon and oxygen, were observed as well as mid- to high-Z elements, e.g., sulfur, chlorine, chromium, manganese, iron, and nickel. In addition, X-ray lines from several tracer elements have been observed after the laser blow-off injection of different impurities, e.g., silicon, titanium, and iron, and during discharges with prefill or a gas puff of neon or argon. These measurements were achieved by optimizing light absorber-foil selection, which defines the detected energy range, and remotely controlled pinhole size, which defines photon flux. The identification of X-ray lines was confirmed by other spectroscopic diagnostics, e.g., by the High-Efficiency XUV Overview Spectrometer, HEXOS, and high-resolution X-ray imaging spectrometer, HR-XIS.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a spectroscopic diagnostic tool for electric field measurements in IShTAR (Ion cyclotron Sheath Test ARrangement)

IShTAR, Ion cyclotron Sheath Test ARrangement, is a linear device dedicated to the investigation of the edge plasma–ICRF (Ion Cyclotron Range of Frequencies) antenna interactions in tokamak edge-like conditions and serves as a platform for a diagnostic development for measuring the electric fields in the vicinity of ICRF antennas. We present here our progress in the development of an optical emission spectroscopy method for measuring the electric fields which concentrates on the changes in the helium spectral line profiles introduced by the external electrical field, i.e., the Stark effect. To be able to fully control the operating parameters, at the first stage of the study, the measurements are conducted on a planar electrode installed in the centre of the plasma column in IShTAR’s helicon plasma source. At the second stage, the measurements are performed in the vicinity of IShTAR’s ICRF antenna.

Kostic, Ana↗

Non-invasive low charge electron beam time-of-arrival diagnostic using a plasmonics-enhanced photoconductive antenna

The use of a plasmonics-enhanced photoconductive antenna (PCA) optically gated by a near infrared (NIR) pulse enables non-invasive time-of-arrival measurements of a low charge electron beam with respect to the NIR reference, achieving picosecond resolution. The measured signal values show the expected scaling with the beam charge and distance from PCA to the beam axis, as the PCA samples the electric field of the passing electron beam. We operate the device with an NIR spot size much larger than the PCA active-area, resulting in a very simple optical setup and alignment procedure, making the plasmonics-enhanced PCA a preferred alternative to more complex timing diagnostics for applications requiring non-invasive picosecond or sub-picosecond timestamping.

43 PARTICLE ACCELERATORS↗

The multi-spectral imaging diagnostic

The Multi-Spectral Imaging system is a new diagnostic that captures simultaneous spectrally filtered images from a common line of sight while maintaining a large étendue and high throughput. Simultaneously imaging several atomic line intensities may enable numerous measurement techniques. By making a novel modification of a polychromator layout, the MSI sequentially filters and focuses images onto commercial CMOS cameras while exhibiting minimal vignetting and aberrations. A four-wavelength system was initially installed and tested on Alcator C-Mod and subsequently moved to TCV. The images are absolutely calibrated and spatially registered enabling 2D mappings of atomic line ratios and absolute line intensities. The spectral transmission of the optical system was calibrated using an integrating sphere of known radiance. The images are inverted by cross-referencing points on TCV with a computer-aided design (CAD) model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A modular, multi-diagnostic, automated shock tube for gas-phase chemistry

A new shock tube has been constructed for investigations of high-temperature chemical kinetics with an emphasis on combustion chemistry. This instrument includes a diaphragmless driver and electrical control of valving. A diaphragmless design significantly improves repeatability of experimental conditions vs the use of diaphragms and leads to an approximate order of magnitude reduction in turnaround time between experiments. Electrical control of valves, combined with diaphragmless operation, also enables remote and automated operation of the shock tube. The design allows for both incident and reflected shock experiments with multiple diagnostics. The performance of the shock tube is demonstrated by reproducing previous literature measurements on the unimolecular decomposition of isobutyl nitrite and cyclohexene.

47 OTHER INSTRUMENTATION↗

First results from the implementation of the ITER diagnostic residual gas analyzer prototype at Wendelstein 7-X

Fusion reactors and long pulse fusion experiments heavily depend on a continuous fuel cycle, which requires detailed monitoring of exhaust gases. We have used a diagnostic residual gas analyzer (DRGA) built as a prototype for ITER and integrated it on the most advanced stellarator fusion experiment, Wendelstein 7-X (W7-X). The DRGA was equipped with a sampling tube and assessed for gas time of flight sample response, effects of magnetic field on gas detection and practical aspects of use in a state of the art fusion environment. The setup was successfully commissioned and operated and was used to observe the gas composition of W7-X exhaust gases. The measured time of flight gas response was found to be in the order of a second for a 7 m sample tube. High values of magnetic field were found to affect the partial pressure readings of the DRGA and suggest that additional shielding is necessary in future experimental campaigns.

47 OTHER INSTRUMENTATION↗

Optimization of switch diagnostics on the MAIZE linear transformer driver

The MAIZE Linear Transformer Driver is made of 40 capacitor-switch-capacitor `bricks' connected in parallel. When these 40 bricks are charged to 100-kV and then discharged synchronously, the MAIZE facility generates a 1-MA current pulse with a 100-ns rise time into a matched load impedance. Discharging each of the capacitors in a brick is carried out by the breakdown of a spark-gap switch, a process which results in the emission of light. Monitoring this output light with a fiber optic coupled to a photomultiplier tube (PMT) and an oscilloscope channel provides information on switch performance and timing jitter– whether a switch red early, late, or in phase with the other switches. However, monitoring each switch with a dedicated detector- oscilloscope channel can be problematic for facilities where the number of switches to be monitored (e.g., 40 on MAIZE) greatly exceeds the number of detector-oscilloscope channels available. The technique of using fibers to monitor light emission from switches can be optimized by treating a PMT as a binary digit or bit and using a combinatorial encoding scheme, where each switch is monitored by a unique combination of fiber- PMT-oscilloscope channels simultaneously. By observing the unique combination of ber-PMT-oscilloscope channels that are turned on, the pre-firing or late-firing of a single switch on MAIZE can be identified by as few as six PMT-oscilloscope channels. The number of PMT-oscilloscope channels, N , required to monitor X switches can be calculated by 2 N = X + 1, where the number '2' is selected because the PMT-oscilloscope acts as a bit. Here, we demonstrate the use of this diagnostic technique on MAIZE. In conclusion, we also present an analysis of how this technique could be scaled to monitor the tens of thousands of switches proposed for various next generation pulsed power facilities.

47 OTHER INSTRUMENTATION↗

Enhanced spatial resolution of Eljen-204 plastic scintillators for use in rep-rated proton diagnostics

A pixelated scintillator has been designed, fabricated, and tested using a laser-accelerated proton source for use in proton diagnostics at rep-rated laser facilities. The work presented here demonstrates the enhanced spatial resolution of thin, organic scintillators through a novel pixelation technique. Furthermore, experimental measurements using laser-generated protons incident onto 130 μm-thick scintillators indicate a >20% reduction in the scintillator point spread function (PSF) for the detectors tested. The best performing pixelated detector reduced the ~200 μm PSF of the stock material to ~150 μm. The fabrication technique may be tailored to reduce the pixel size and achieve higher spatial resolutions.

47 OTHER INSTRUMENTATION↗