Search NASA⌕ Search

SEARCH · Search NASA

Results for “error indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Accuracy of sea ice temperature derived from the advanced very high resolution radiometer

The accuracy of Arctic sea ice surface temperatures T(sub s) dericed from advanced very high resolution radiometer (AVHRR) thermal channels is evaluated in the cold seasons by comparing them with surface air temperatures T(sub air) from drifting buoys and ice stations. We use three different estimates of satellite surface temperatures, a direct estimate from AVHRR channel 4 with only correction for the snow surface emissivity but not for the atmosphere, a single-channel regression of T(sub s) with T(sub air), and Key and Haefliger's (1992) polar multichannel algorithm. We find no measurable bias in any of these estimates and few differences in their statistics. The similar performance of all three methods indicates that an atmospheric water vapor correction is not important for the dry winter atmosphere in the central Arctic, given the other sources of error that remain in both the satellite and the comparison data. A record of drifting station data shows winter air temperature to be 1.4 C warmer than the snow surface temperature. `Correcting' air temperatures to skin temperature by subtracting this amount implies that satellite T(sub s) estimates are biased warm with respect to skin temperature by about this amount. A case study with low-flying aircraft data suggests that ice crystal precipitation can cause satellite estimates of T(sub s) to be several degrees warmer than radiometric measurements taken close to the surface, presumably below the ice crystal precipitation layer. An analysis in which errors are assumed to exist in all measurements, not just the satellite measurements, gives a standard deviation in the satellite estimates of 0.9 C, about half the standard deviation of 1.7 C estimated by assigning all the variation between T(sub s) and T(sub air) to errors in T(sub s).

Yu, Y.↗

Precision orbit determination for TOPEX/POSEIDON

The TOPEX/POSEIDON mission objective requires that the radial position of the spacecraft be determined with an accuracy better than 13 cm RMS (root mean square). This stringent requirement is an order of magnitude below the accuracy achieved for any altimeter mission prior to the definition of the TOPEX/POSEIDON mission. To satislfy this objective, the TOPEX Precision Orbit determination (POD) Team was established as a joint effort between the NASA Goddard Space Flight Center and the University of Texas at Austin, with collaboration from the University of Colorado and the Jet Propulsion Laboratory. During the prelaunch development and the post launch verification phases, the POD team improved, calibrated, and validated the precision orbit determination computer software systems. The accomplishments include (1) increased accuracy of the gravity and surface force models and (2) improved peformance of both laser ranging and Doppler tracking systems. The result of these efforts led to orbit accuracies for TOPEX/POSEIDON which are significantly better than the original mission requirement. Tests based on data fits, covariance analysis, and orbit comparisons indicate that the radial component of the TOPEX/POSEIDON spacecraft is determined, relative to the Earth's mass center, with an root mean square (RMS) error in the range of 3 to 4 cm RMS. This orbit accuracy, together with the near continuous dual-frequency altimetry from this mission, provides the means to determine the ocean's dynamic topography with an unprecedented accuracy.

Tapley, B. D.↗

Reducing Tilt-Related Errors Of Inductive Proximity Sensors

Simple modification of inductive proximity sensor nearly eliminates tilt-related readout error occurring when sensor used to measure thickness of dielectric layer on metal substrate (e.g., to measure thickness of insulating blanket on boiler). Sensor indicates true thickness when equipped with hemispherical contact knob ensuring correct zero-offset distance at measurement location.

Cotty, Glenn M., Jr.↗

Sensor Spatial Distortion, Visual Latency, and Update Rate Effects on 3D Tracking in Virtual Environments

Several common defects that we have sought to minimize in immersing virtual environments are: static sensor spatial distortion, visual latency, and low update rates. Human performance within our environments during large amplitude 3D tracking was assessed by objective and subjective methods in the presence and absence of these defects. Results show that 1) removal of our relatively small spatial sensor distortion had minor effects on the tracking activity, 2) an Adapted Cooper-Harper controllability scale proved the most sensitive subjective indicator of the degradation of dynamic fidelity caused by increasing latency and decreasing frame rates, and 3) performance, as measured by normalized RMS tracking error or subjective impressions, was more markedly influenced by changing visual latency than by update rate.

Ellis, S. R.↗

Measurement and Simulation of Spontaneous Raman Scattering Spectra in High-Pressure, Fuel-Rich H2-Air Flames

Rotational vibrational spontaneous Raman spectra (SRS) of H2, N2, and H2O have been measured in H2-air flames at pressures up to 30 atm as a first stem towards establishing a comprehensive Raman spectral database for temperatures and species in high-pressure combustion. A newly developed high-pressure burner facility provides steady, reproducible flames with a high degree of flow precision. We have obtained an initial set of measurements that indicate the spectra are of sufficient quality in terms of spectral resolution, wavelength coverage, and signal-to-noise ratio for use in future reference standards. The fully resolved Stokes and anti-Stokes shifted SRS spectra were collected in the visible wavelength range (400-700 nm) using pulse-stretched 532 nm excitation and a non-intensified CCD spectrograph with a high-speed shutter. Reasonable temperatures were determined via the intensity distribution of rotational H2 lines at stoichiometry and fuel-rich conditions. Theoretical Raman spectra of H2 were computed using a semi-classical harmonic-oscillator model with recent pressure broadening data and were compared with experimental results. The data and simulation indicated that high-J rotational lines of H2 might interfere with the N2 vibrational Q-branch lines, and this could lead to errors in N2-Raman thermometry based on the line-fitting method. From a comparison of N2 Q-branch spectra in lean H2 low-pressure (1.2 atm) and high-pressure (30 atm) flames, we found no significant line-narrowing or -broadening effects at the current spectrometer resolution of 0.04 nm.

Kojima, Jun↗

Discovery of a Be/X-Ray Binary Consistent with the Location of GRO J2058+42

GRO J2058+42 is a 195 s transient X-ray pulsar discovered in 1995 with BATSE. In 1996, RXTE located GRO J2058+42 to a 90% confidence error circle with a 4 radius. On 2004 February 20, the region including the error circle was observed with Chandra ACIS-I. No X-ray sources were detected within the error circle; however, two faint sources were detected in the ACIS-I field of view. We obtained optical observations of the brightest object, CXOU J205847.5+414637, which had about 64 X-ray counts and was just 013 outside the error circle. The optical spectrum contains a strong Ha line and corresponds to an inhued object in the Two Micron All Sky Survey catalog, indicating a Be/X-ray binary system. Pulsations were not detected in the Chandra observations, but similar flux variations and distance estimates suggest that CXOU J205847.5+414637 and GRO J2058+42 are the same object. We present results from the Chandra observation, optical observations, new and previously unreported RXTE observations, and a reanalysis of a ROSAT observation.

Wilson, Colleen↗

Macro-Scale Findings of the DebriSat Debris Field Obtained from X-Rays of the Catch Panels

The DebriSat project analyzes the debris from a hypervelocity impact test conducted on a 56 kg-simulated satellite target in 2014. Its purpose is to generate a comprehensive database of the size, mass, material, shape, and the radar and optical properties of fragments generated from orbital collisions of modern-built spacecraft. Three hundred ninety-one foam catch panels from the DebriSat test have been X-rayed to locate the particles within them for subsequent extraction and assessment. The data from the tens of thousands of extracted particles has heretofore been the focus of the debris assessment. The work presented here connects the X-ray sample location images to reconstruct the 3D distribution of the entire fragment cloud. Although some errors are inherent to the process, this 3D database is valuable for qualitative studies of size and energy distributions. Further, the 3D database can indicate the extent of bending or breaking of the fragments as they decelerated to full capture. By virtue of its full sphere perspective, the 3D database allows graphical insight to the physics of the collision and breakup. This 3D representation has been developed as a “point and click” graphical interface to retrieve the full data set on individual recovered and assessed fragments within the growing database. Overall, this macro-level screening technique has added enormous insight to the experiment in unexpected ways.

Allen, Anthony↗

Estimating the concentration of total suspended solids in inland and coastal waters from Sentinel-2 MSI: A semi-analytical approach

Inland and coastal waters provide key ecosystem services and are closely linked to human well-being. In this study, we propose a semi-analytical method, which can be applied to Sentinel-2 MultiSpectral Instrument (MSI) images to retrieve high spatial-resolution total suspended solids (TSS) concentration in a broad spectrum of aquatic ecosystems ranging from clear to extremely turbid waters. The presented approach has four main steps. First, the remote sensing reflectance ( R rs ) at a band lacking in MSI (620 nm) is estimated through an empirical relationship from R rs at 665 nm. Second, waters are classified into four types (clear, moderately turbid, highly turbid, and extremely turbid). Third, semi-analytical algorithms are used to estimate the particulate backscattering coefficient ( b bp ) at a reference band depending on the water types. Last, TSS is estimated from bbp at the reference band. Validation and comparison of the proposed method with three existing methods are performed using a simulated dataset ( N = 1000), an in situ dataset collected from global inland and coastal waters ( N = 1265) and satellite matchups ( N = 40). Results indicate that the proposed method can improve TSS estimation and provide accurate retrievals of TSS from all three datasets, with a median absolute percentage error (MAPE) of 14.88 %, 31.50 % and 41.69 % respectively. We also present comparisons of TSS mapping between the Sentinel-3 Ocean and Land Colour Instrument (OLCI) and MSI in Lake Kasumigaura, Japan and the Tagus Estuary, Portugal. Results clearly demonstrate the advantages of using MSI for TSS monitoring in small water bodies such as rivers, river mouths and other nearshore waters. MSI can provide more detailed and realistic TSS estimates than OLCI in these water bodies. The proposed TSS estimation method was applied to MSI images to produce TSS time-series in Lake Kasumigaura, which showed good agreements with in situ and OLCI-derived TSS time-series.

Sentinel-2↗

WE-H-BRC-08: Examining Credentialing Criteria and Poor Performance Indicators for IROC Houston’s Anthropomorphic Head and Neck Phantom

Purpose: To analyze the most recent results of IROC Houston’s anthropomorphic H&N phantom to determine the nature of failing irradiations and the feasibility of altering pass/fail credentialing criteria. Methods: IROC Houston’s H&N phantom, used for IMRT credentialing for NCI-sponsored clinical trials, requires that an institution’s treatment plan must agree with measurement within 7% (TLD doses) and ≥85% pixels must pass 7%/4 mm gamma analysis. 156 phantom irradiations (November 2014 – October 2015) were re-evaluated using tighter criteria: 1) 5% TLD and 5%/4 mm, 2) 5% TLD and 5%/3 mm, 3) 4% TLD and 4%/4 mm, and 4) 3% TLD and 3%/3 mm. Failure/poor performance rates were evaluated with respect to individual film and TLD performance by location in the phantom. Overall poor phantom results were characterized qualitatively as systematic (dosimetric) errors, setup errors/positional shifts, global but non-systematic errors, and errors affecting only a local region. Results: The pass rate for these phantoms using current criteria is 90%. Substituting criteria 1-4 reduces the overall pass rate to 77%, 70%, 63%, and 37%, respectively. Statistical analyses indicated the probability of noise-induced TLD failure at the 5% criterion was <0.5%. Using criteria 1, TLD results were most often the cause of failure (86% failed TLD while 61% failed film), with most failures identified in the primary PTV (77% cases). Other criteria posed similar results. Irradiations that failed from film only were overwhelmingly associated with phantom shifts/setup errors (≥80% cases). Results failing criteria 1 were primarily diagnosed as systematic: 58% of cases. 11% were setup/positioning errors, 8% were global non-systematic errors, and 22% were local errors. Conclusion: This study demonstrates that 5% TLD and 5%/4 mm gamma criteria may be both practically and theoretically achievable. Further work is necessary to diagnose and resolve dosimetric inaccuracy in these trials, particularly for systematic dose errors. This work is funded by NCI Grant CA180803.

60 APPLIED LIFE SCIENCES↗

Carbon and Oxygen Isotope Measurements of Ordinary Chondrite (OC) Meteorites from Antarctica Indicate Distinct Carbonate Species Using a Stepped Acid Extraction Procedure

The purpose of this study is to characterize the stable isotope values of terrestrial, secondary carbonate minerals from five Ordinary Chondrite (OC) meteorites collected in Antarctica. These samples were identified and requested from NASA based upon their size, alteration history, and collection proximity to known Martian meteorites. They are also assumed to be carbonate-free before falling to Earth. This research addresses two questions involving Mars carbonates: 1) characterize terrestrial, secondary carbonate isotope values to apply to Martian meteorites for isolating in-situ carbonates, and 2) increase understanding of carbonates formed in cold and arid environments with Antarctica as an analog for Mars. Two samples from each meteorite, each approximately 0.5 grams, were crushed and dissolved in pure phosphoric acid for 3 sequential reactions: a) R times 0 for 1 hour at 30 degrees Centigrade (fine calcite extraction), b) R times 1 for 18 hours at 30 degrees Centigrade (course calcite extraction), and c) R times 2 for 3 hours at 150 degrees Centigrade (siderite and/or magnesite extraction). CO (sub 2) was distilled by freezing with liquid nitrogen from each sample tube, then separated from organics and sulfides with a TRACE GC using a Restek HayeSep Q 80/100 6 foot 2 millimeter stainless column, and then analyzed on a Thermo MAT 253 Isotope Ratio Mass Spectrometer (IRMS) in Dual Inlet mode. This system was built at NASA/JSC over the past 3 years and proof-tested with known carbonate standards to develop procedures, assess yield, and quantify expected error bands. Two distinct species of carbonates are found: 1) calcite, and 2) non-calcite carbonate (future testing will attempt to differentiate siderite from magnesite). Preliminary results indicate the terrestrial carbonates are formed at approximately sigma (sup 13) C equal to plus 5 per mille, which is consistent with atmospheric CO (sub 2) sigma (sup 13) C equal to minus 7 per mille and fractionation of plus12 per mille based upon polar temperature of -20 degrees Centigrade. The oxygen values fractionate sigma (sup 18) O equal to minus 10-20 per mille lighter between the R times 0 and R times 1 reactions at 30 degrees Centigrade. The carbonate oxygen isotope measurements are consistently heavier than expected with meteoric water and temperatures from Antarctica, perhaps due to secondary carbonate formation during curation in Houston, TX.

Evans, Michael E.↗

“Plug-and-Play” potentials: Investigating quantum effects in (H{sub 2}){sub 2}–Li{sup +}–benzene

Quantum and anharmonic effects are investigated in (H{sub 2}){sub 2}–Li{sup +}–benzene, a model for hydrogen adsorption in metal-organic frameworks and carbon-based materials, using rigid-body diffusion Monte Carlo (RBDMC) simulations. The potential-energy surface (PES) is calculated as a modified Shepard interpolation of M05-2X/6-311+G(2df,p) electronic structure data. The RBDMC simulations yield zero-point energies (ZPE) and probability density histograms that describe the ground-state nuclear wavefunction. Binding a second H{sub 2} molecule to the H{sub 2}–Li{sup +}–benzene complex increases the ZPE of the system by 5.6 kJ mol{sup −1} to 17.6 kJ mol{sup −1}. This ZPE is 42% of the total electronic binding energy of (H{sub 2}){sub 2}–Li{sup +}–benzene and cannot be neglected. Our best estimate of the 0 K binding enthalpy of the second H{sub 2} to H{sub 2}–Li{sup +}–benzene is 7.7 kJ mol{sup −1}, compared to 12.4 kJ mol{sup −1} for the first H{sub 2} molecule. Anharmonicity is found to be even more important when a second (and subsequent) H{sub 2} molecule is adsorbed; use of harmonic ZPEs results in significant error in the 0 K binding enthalpy. Probability density histograms reveal that the two H{sub 2} molecules are found at larger distance from the Li{sup +} ion and are more confined in the θ coordinate than in H{sub 2}–Li{sup +}–benzene. They also show that both H{sub 2} molecules are delocalized in the azimuthal coordinate, ϕ. That is, adding a second H{sub 2} molecule is insufficient to localize the wavefunction in ϕ. Two fragment-based (H{sub 2}){sub 2}–Li{sup +}–benzene PESs are developed. These use a modified Shepard interpolation for the Li{sup +}–benzene and H{sub 2}–Li{sup +}–benzene fragments, and either modified Shepard interpolation or a cubic spline to model the H{sub 2}–H{sub 2} interaction. Because of the neglect of three-body H{sub 2}, H{sub 2}, Li{sup +} terms, both fragment PESs lead to overbinding of the second H{sub 2} molecule by 1.5 kJ mol{sup −1}. Probability density histograms, however, indicate that the wavefunctions for the two H{sub 2} molecules are effectively identical on the “full” and fragment PESs. This suggests that the 1.5 kJ mol{sup −1} error is systematic over the regions of configuration space explored by our simulations. Notwithstanding this, modified Shepard interpolation of the weak H{sub 2}–H{sub 2} interaction is problematic and we obtain more accurate results, at considerably lower computational cost, using a cubic spline interpolation. Indeed, the ZPE of the fragment-with-spline PES is identical, within error, to the ZPE of the full PES. This fragmentation scheme therefore provides an accurate and inexpensive method to study higher hydrogen loading in this and similar systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MODIS Tree Cover Validation for the Circumpolar Taiga-Tundra Transition Zone

A validation of the 2005 500m MODIS vegetation continuous fields (VCF) tree cover product in the circumpolar taiga-tundra ecotone was performed using high resolution Quickbird imagery. Assessing the VCF's performance near the northern limits of the boreal forest can help quantify the accuracy of the product within this vegetation transition area. The circumpolar region was divided into longitudinal zones and validation sites were selected in areas of varying tree cover where Quickbird imagery is available in Google Earth. Each site was linked to the corresponding VCF pixel and overlaid with a regular dot grid within the VCF pixel's boundary to estimate percent tree crown cover in the area. Percent tree crown cover was estimated using Quickbird imagery for 396 sites throughout the circumpolar region and related to the VCF's estimates of canopy cover for 2000-2005. Regression results of VCF inter-annual comparisons (2000-2005) and VCF-Quickbird image-interpreted estimates indicate that: (1) Pixel-level, inter-annual comparisons of VCF estimates of percent canopy cover were linearly related (mean R(sup 2) = 0.77) and exhibited an average root mean square error (RMSE) of 10.1 % and an average root mean square difference (RMSD) of 7.3%. (2) A comparison of image-interpreted percent tree crown cover estimates based on dot counts on Quickbird color images by two different interpreters were more variable (R(sup 2) = 0.73, RMSE = 14.8%, RMSD = 18.7%) than VCF inter-annual comparisons. (3) Across the circumpolar boreal region, 2005 VCF-Quickbird comparisons were linearly related, with an R(sup 2) = 0.57, a RMSE = 13.4% and a RMSD = 21.3%, with a tendency to over-estimate areas of low percent tree cover and anomalous VCF results in Scandinavia. The relationship of the VCF estimates and ground reference indicate to potential users that the VCF's tree cover values for individual pixels, particularly those below 20% tree cover, may not be precise enough to monitor 500m pixel-level tree cover in the taiga-tundra transition zone.

Montesano, P. M.↗

Summary and Annotated Bibliography of Measurement Error Corrections with Potential Application in Future Quesst Mission Community Noise Studies

This document is motivated by likely needs of the Quesst mission community response tests, which will culminate in data collection and estimation of dose-response regression relationships for consideration by domestic and international aviation regulators. Furthermore, basic research questions evaluating interactions between rates of community annoyance, dose levels, and indicators of the presence of rattle, vibration, and startle hinge on hypothesis testing in the context of regression models. For a variety of reasons, noise doses may be known only imprecisely and may not reflect the actual level experienced by responding subjects. These differences between true dose and estimated dose, be they systematic or random, constitute covariate measurement error. Available statistics literature speaks to the impacts of measurement error on regression models, both in terms of bias in estimated coefficients and predicted values, and in terms of the loss of statistical power for hypothesis testing. Given the particulars of a categorical annoyance response variable and a continuous noise dose predictor variable subject to measurement error during testing, the emphasis of this report is on findings and methods pertinent to generalized linear (and mixed) models likely to be employed during the Quesst mission community tests. We reach the following conclusions: 1. Of four reviewed methods, structural Bayesian measurement error models and simulation extrapolation (SIMEX) may be the most readily applicable to Quesst mission community noise study objectives. 2. If warranted, a linear measurement model can help model systematic sources of measurement error that the classical measurement error does not. 3. For its ready implementation and small additional input requirements, simulation extrapolation may be ideally suited for addressing secondary research questions involving interactions between annoyance, noise dose, and other factors through hypothesis testing. 4. For their flexibility and ability to propagate uncertainty, structural Bayesian hierarchical models have great appeal for mission purposes; some care may be needed in developing appropriate probability models describing actual noise exposure during testing. An annotated bibliography logs additional papers and resources that may be of value to analysts in other projects and disciplines.

Dose-Response Model↗

Battery Charge Curve Prediction via Feature Extraction and Supervised Machine Learning

Real-time onboard state monitoring and estimation of a battery over its lifetime is indispensable for the safe and durable operation of battery-powered devices. In this study, a methodology to predict the entire constant-current cycling curve with limited input information that can be collected in a short period of time is developed. A total of 10 066 charge curves of LiNiO 2 -based batteries at a constant C-rate are collected. With the combination of a feature extraction step and a multiple linear regression step, the method can accurately predict an entire battery charge curve with an error of < 2% using only 10% of the charge curve as the input information. The method is further validated across other battery chemistries (LiCoO 2 -based) using open-access datasets. The prediction error of the charge curves for the LiCoO 2 -based battery is around 2% with only 5% of the charge curve as the input information, indicating the generalization of the developed methodology for predicting battery cycling curves. The developed method paves the way for fast onboard health status monitoring and estimation for batteries during practical applications.

25 ENERGY STORAGE↗

An a priori evaluation of a principal component and artificial neural network based combustion model in diesel engine conditions

A principal component analysis (PCA) and artificial neural network (ANN) based chemistry tabulation approach is presented. ANNs are used to map the thermochemical state onto a low-dimensional manifold consisting of five control variables that have been identified using PCA. Three canonical configurations are considered to train the PCA-ANN model: a series of homogeneous reactors, a nonpremixed flamelet, and a two-dimensional lifted flame. The performance of the model in predicting the thermochemical manifold of a spatially-developing turbulent jet flame in diesel engine thermochemical conditions is a priori evaluated using direct numerical simulation (DNS) data. The PCA-ANN approach is compared with a conventional tabulation approach (tabulation using ad hoc defined control variables and linear interpolation). The PCA-ANN model provides higher accuracy and requires several orders of magnitude less memory. Here, these observations indicate that the PCA-ANN model is superior for chemistry tabulation, especially for modelling complex chemistries that present multiple combustion modes as observed in diesel combustion. The performance of the PCA-ANN model is then compared to the optimal estimator, i.e. the conditional mean from the DNS. The results indicate that the PCA-ANN model gives high prediction accuracy, comparable to the optimal estimator, especially for major species and the thermophysical properties. Higher errors are observed for the minor species and reaction rate predictions when compared to the optimal estimator. It is shown that the prediction of minor species and reaction rates can be improved by using training data that exhibits a variation of parameters as observed in the turbulent flame. The output of the ANN is analysed to assess mass conservation. It is observed that the ANN incurs a mean absolute error of 0.05% in mass conservation. Furthermore, it is demonstrated that this error can be reduced by modifying the cost function of the ANN to penalise for deviation from mass conservation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing High-Pressure Structural Evolution in Polyurea with In Situ Energy-Dispersive X-ray Diffraction and Molecular Dynamics Simulations

Polyurea, an elastomer with a phase-segregated microstructure, has been proven as an effective coating in defense applications. To gain a more complete understanding of the high-pressure atomic-level morphology of these phases and to validate molecular dynamics (MD) simulations, multi-angle energy-dispersive X-ray diffraction experiments were performed in situ up to pressures of ~6 GPa at room temperature. Structure factors were obtained and compared to MD simulations with an average error of less than 5% between major peak positions. The first sharp diffraction peak shifted from 4.56 Å to lower d-spacing with pressure, indicating compression between hard segments. This was further supported by the behavior of a peak at ~3.86 Å from the pair distribution function (PDF), suspected to represent π-stacking and separation between soft segments. Compression within the hard segments themselves is minimal as low-r peaks in the PDF are not greatly affected by pressure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron tomography of axially symmetric objects using 14 MeV neutrons from a portable neutron generator

In nuclear boiling water reactor cores, the distribution of water and steam (void) is essential for both safety and efficiency reasons. In order to enhance predictive capabilities, void distribution assessment is performed in two-phase test-loops under reactor-relevant conditions. This article proposes the novel technique of fast-neutron tomography using a portable deuterium-tritium neutron generator to determine the time-averaged void distribution in these loops. Fast neutrons have the advantage of high transmission through the metallic structures and pipes typically concealing a thermal-hydraulic test loop, while still being fairly sensitive to the water/void content. However, commercially available fast-neutron generators also have the disadvantage of a relatively low yield and fast-neutron detection also suffers from relatively low detection efficiency. Fortunately, some loops are axially symmetric, a property which can be exploited to reduce the amount of data needed for tomographic measurement, thus limiting the interrogation time needed. In this article, three axially symmetric test objects depicting a thermal-hydraulic test loop have been examined; steel pipes with outer diameter 24 mm, thickness 1.5 mm, and with three different distributions of the plastic material POM inside the pipes. Data recorded with the FANTOM fast-neutron tomography instrument have been used to perform tomographic reconstructions to assess their radial material distribution. Here, a dedicated tomographic algorithm that exploits the symmetry of these objects has been applied, which is described in the paper. Results are demonstrated in 20 rixel (radial pixel) reconstructions of the interior constitution and 2D visualization of the pipe interior is demonstrated. The local POM attenuation coefficients in the rixels were measured with errors (RMS) of 0.025, 0.020, and 0.022 cm{sup −1}, solid POM attenuation coefficient. The accuracy and precision is high enough to provide a useful indication on the flow mode, and a visualization of the radial material distribution can be obtained. A benefit of this system is its potential to be mounted at any axial height of a two-phase test section without requirements for pre-fabricated entrances or windows. This could mean a significant increase in flexibility of the void distribution assessment capability at many existing two-phase test loops.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗