SU-E-T-495: Neutron Induced Electronics Failure Rate Analysis for a Single Room Proton Accelerator

Purpose: To determine the failure rate as a function of neutron dose of the range modulator's servo motor controller system (SMCS) while shielded with Borated Polyethylene (BPE) and unshielded in a single room proton accelerator. Methods: Two experimental setups were constructed using two servo motor controllers and two motors. Each SMCS was then placed 30 cm from the end of the plugged proton accelerator applicator. The motor was then turned on and observed from outside of the vault while being irradiated to known neutron doses determined from bubble detector measurements. Anytime the motor deviated from the programmed motion a failure was recorded along with the delivered dose. The experiment was repeated using 9 cm of BPE shielding surrounding the SMCS. Results: Ten SMCS failures were recorded in each experiment. The dose per monitor unit for the unshielded SMCS was 0.0211 mSv/MU and 0.0144 mSv/MU for the shielded SMCS. The mean dose to produce a failure for the unshielded SMCS was 63.5 ± 58.3 mSv versus 17.0 ±12.2 mSv for the shielded. The mean number of MUs between failures were 2297 ± 1891 MU for the unshielded SMCS and 2122 ± 1523 MU for the shielded. A Wilcoxon Signed Ranked test showed the dose between failures were significantly different (P value = 0.044) while the number of MUs between failures were not (P value = 1.000). Statistical analysis determined a SMCS neutron dose of 5.3 mSv produces a 5% chance of failure. Depending on the workload and location of the SMCS, this failure rate could impede clinical workflow. Conclusion: BPE shielding was shown to not reduce the average failure of the SMCS and relocation of the system outside of the accelerator vault was required to lower the failure rate enough to avoid impeding clinical work flow.

07 ISOTOPE AND RADIATION SOURCES↗

TU-F-BRF-09: Feasibility Study of Spatial and Temporal Fractionation Using a Table-Top Image-Guided MRT System

Purpose: Microbeam radiation therapy is a promising experimental radiotherapy method for cancer treatment. Synchrotron studies have shown that MRT can preferentially ablate tumors while mostly preserving the surrounding normal tissues. Our purpose is to develop a compact microbeam irradiator that can be accessible for laboratory research on MRT's therapeutic mechanism, with the ultimate goal of translating this technique for clinical applications. Utilizing a carbon nanotube field emission X-ray source array, our lab has developed a first of its kind table-top microbeam irradiator. The purpose of this study is to investigate the possibility of increasing the total dose to the tumor region using spatial and temporal fractionation. Methods: MRI and CT scans were acquired and registered to locate both the target region and the landmark in the treatment coordinate space. A crossbeam treatment configuration was planned to achieve the desired dosage and tumor coverage. One array of 300 μm-thick microbeams was delivered to the target on the first day. Another array, perpendicular to the first one, was delivered the next day targeting the same region. The feasibility of this image-guided MRT procedure was evaluated using a phantom. Gafchromic EBT2 film was employed to characterize the targeting accuracy and the delivered tumor dose. Results: The preliminary phantom study showed that a cross-pattern of microbeam arrays was successfully delivered with sub-millimeter targeting accuracy. The delivered dose in the target region was doubled. The fraction of tumor volume that received the peak dose was increased. Conclusion: Temporal fractionation of crosspatterned microbeams can be delivered to the same target region. The feasibility of this procedure was investigated with a phantom study. Once implemented, this procedure has the potential of increasing the tumor control effect of MRT and of achieving better normal tissue recovery.

60 APPLIED LIFE SCIENCES↗

Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam

Purpose: IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement of 0.75 times the inner cavity radius (0.75R) for heavy ion beams. Theoretical models by Palmans and by Bhullar and Watchman confirmed this value. However, the experimental results vary from author to author. The purpose of this study is to accurately measure the displacement and explain the past experimental discrepancies. Methods: In this work, we measured the EPOM of cylindrical ionization chambers with high accuracy by comparing the Bragg-peak position obtained with cylindrical ionization chambers (PTW 30013, PTW 31016) to that obtained using a plane-parallel ionization chamber (PTW 34045). Results: The EPOMs of PTW 30013 and 31016 were shifted by 0.92 ± 0.07 R with R = 3.05 mm and 0.90 ± 0.14 R with R = 1.45 mm, respectively, from the reference point toward the source. Conclusions: The EPOMs obtained were greater than the value of 0.75R proposed by the IAEA TRS-398 and the analytical results.

07 ISOTOPE AND RADIATION SOURCES↗

SU-D-213-03: Towards An Optimized 3D Scintillation Dosimetry Tool for Quality Assurance of Dynamic Radiotherapy Techniques

Purpose: The purpose of this work is to simulate a multi-focus plenoptic camera used as the measuring device in a real-time three-dimensional scintillation dosimeter. Simulating and optimizing this realistic optical system will bridge the technological gap between concept validation and a clinically viable tool that can provide highly efficient, accurate and precise measurements for dynamic radiotherapy techniques. Methods: The experimental prototype, previously developed for proof of concept purposes, uses an off-the-shelf multi-focus plenoptic camera. With an array of interleaved microlenses of different focal lengths, this camera records spatial and angular information of light emitted by a plastic scintillator volume. The three distinct microlens focal lengths were determined experimentally for use as baseline parameters by measuring image-to-object magnification for different distances in object space. A simulated plenoptic system was implemented using the non-sequential ray tracing software Zemax: this tool allows complete simulation of multiple optical paths by modeling interactions at interfaces such as scatter, diffraction, reflection and refraction. The active sensor was modeled based on the camera manufacturer specifications by a 2048×2048, 5 µm-pixel pitch sensor. Planar light sources, simulating the plastic scintillator volume, were employed for ray tracing simulations. Results: The microlens focal lengths were determined to be 384, 327 and 290 µm. A realistic multi-focus plenoptic system, with independently defined and optimizable specifications, was fully simulated. A f/2.9 and 54 mm-focal length Double Gauss objective was modeled as the system’s main lens. A three-focal length hexagonal microlens array of 250-µm thickness was designed, acting as an image-relay system between the main lens and sensor. Conclusion: Simulation of a fully modeled multi-focus plenoptic camera enables the decoupled optimization of the main lens and microlens specifications. This work leads the way to improving the 3D dosimeter’s achievable resolution, efficiency and build for providing a quality assurance tool fully meeting clinical needs. M.R. is financially supported by a Master’s Canada Graduate Scholarship from the NSERC. This research is also supported by the NSERC Industrial Research Chair in Optical Design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-D-210-04: Using Radiotherapy Biomaterials to Brand and Track Deadly Cancer Cells

Purpose: Metastasis accounts for over 90% of all cancer associated suffering and death and arguably presents the most formidable challenges in cancer management. The detection of metastatic or rare circulating tumor cells (CTCs) in blood or lymph nodes remains a formidable technological challenge. In this study, we investigated the time needed to label each cancer cell in-situ (right at the source tumor) with sufficient number of GNPs that will allow enhanced non-invasive detection via photoacoustic imaging in the lymph nodes. Such in-situ labeling can be achieved via sustained release of the GNPs from Radiotherapy (RT) biomaterials (e.g. fiducials, spacers) coated/loaded with the GNP. Methods: The minimum concentration (1000 GNPs/cell for 50nm GNPs) to detect GNPs with photoacoustic imaging method was experimentally measured by Mallidi et al. and fixed at the tumor sub-volume periphery. In this work, the GNPs were assumed to diffuse from a point source, placed in the middle of a 2–3cm tumor, with an initial concentration of 7–30 mg/g. The time required to label the cells with GNPs was calculated by solving the three dimensional diffusion-reaction equation analytically. The diffusion coefficient of 10nm GNPs was experimentally determined previously. Stokes-Einstein equation was used to calculate the diffusion coefficients for other sizes (2–50nm) of GNPs. The cellular uptake rate constants for several sizes of GNPs were experimentally measured by Jin et al. Results: The time required to label the cells was found 0.635–15.91 days for 2–50nm GNPs with an initial concentration of 7 mg/g GNPs in a 2 cm tumor; 1.379–34.633 days for 2–50nm GNPs with an initial concentration of 30 mg/g GNPs in a 3cm tumor. Conclusion: Our results highlight new potential for labeling CTCs with GNPs released from smart RT biomaterials (i.e. fiducials or spacers loaded with the GNP) towards enhanced non-invasive imaging/detection via photoacoustic imaging.

60 APPLIED LIFE SCIENCES↗

SU-E-T-365: Estimation of Neutron Ambient Dose Equivalents for Radioprotection Exposed Workers in Radiotherapy Facilities Based On Characterization Patient Risk Estimation

Purpose: Previous measurements with Bonner spheres{sup 1} showed that normalized neutron spectra are equal for the majority of the existing linacs{sup 2}. This information, in addition to thermal neutron fluences obtained in the characterization procedure{sup 3}3, would allow to estimate neutron doses accidentally received by exposed workers, without the need of an extra experimental measurement. Methods: Monte Carlo (MC) simulations demonstrated that the thermal neutron fluence distribution inside the bunker is quite uniform, as a consequence of multiple scatter in the walls{sup 4}. Although inverse square law is approximately valid for the fast component, a more precise calculation could be obtained with a generic fast fluence distribution map around the linac, from MC simulations{sup 4}. Thus, measurements of thermal neutron fluences performed during the characterization procedure{sup 3}, together with a generic unitary spectra{sup 2}, would allow to estimate the total neutron fluences and H*(10) at any point{sup 5}. As an example, we compared estimations with Bonner sphere measurements{sup 1}, for two points in five facilities: 3 Siemens (15–23 MV), Elekta (15 MV) and Varian (15 MV). Results: Thermal neutron fluences obtained from characterization, are within (0.2–1.6×10{sup 6}) cm−{sup 2}•Gy{sup −1} for the five studied facilities. This implies ambient equivalent doses ranging from (0.27–2.01) mSv/Gy 50 cm far from the isocenter and (0.03–0.26) mSv/Gy at detector location with an average deviation of ±12.1% respect to Bonner measurements. Conclusion: The good results obtained demonstrate that neutron fluence and H*(10) can be estimated based on: (a) characterization procedure established for patient risk estimation in each facility, (b) generic unitary neutron spectrum and (c) generic MC map distribution of the fast component. [1] Radiat. Meas (2010) 45: 1391 – 1397; [2] Phys. Med. Biol (2012) 5 7:6167–6191; [3] Med. Phys (2015) 42:276 - 281. [4] IFMBE (2012) 39: 1245–1248. [5] ICRU Report 57 (1998)

60 APPLIED LIFE SCIENCES↗

Multisource inverse-geometry CT. Part II. X-ray source design and prototype

Purpose: This paper summarizes the development of a high-power distributed x-ray source, or “multisource,” designed for inverse-geometry computed tomography (CT) applications [see B. De Man et al., “Multisource inverse-geometry CT. Part I. System concept and development,” Med. Phys. 43, 4607–4616 (2016)]. The paper presents the evolution of the source architecture, component design (anode, emitter, beam optics, control electronics, high voltage insulator), and experimental validation. Methods: Dispenser cathode emitters were chosen as electron sources. A modular design was adopted, with eight electron emitters (two rows of four emitters) per module, wherein tungsten targets were brazed onto copper anode blocks—one anode block per module. A specialized ceramic connector provided high voltage standoff capability and cooling oil flow to the anode. A matrix topology and low-noise electronic controls provided switching of the emitters. Results: Four modules (32 x-ray sources in two rows of 16) have been successfully integrated into a single vacuum vessel and operated on an inverse-geometry computed tomography system. Dispenser cathodes provided high beam current (>1000 mA) in pulse mode, and the electrostatic lenses focused the current beam to a small optical focal spot size (0.5 × 1.4 mm). Controlled emitter grid voltage allowed the beam current to be varied for each source, providing the ability to modulate beam current across the fan of the x-ray beam, denoted as a virtual bowtie filter. The custom designed controls achieved x-ray source switching in <1 μs. The cathode-grounded source was operated successfully up to 120 kV. Conclusions: A high-power, distributed x-ray source for inverse-geometry CT applications was successfully designed, fabricated, and operated. Future embodiments may increase the number of spots and utilize fast read out detectors to increase the x-ray flux magnitude further, while still staying within the stationary target inherent thermal limitations.

60 APPLIED LIFE SCIENCES↗

SU-F-T-08: Brachytherapy Film Dosimetry in a Water Phantom for a Ring and Tandem HDR Applicator

Purpose: The feasibility of dose measurement using new generation EBT3 film was explored in a water phantom for a ring and tandem HDR applicator for measurements tracking mucosal dose during cervical brachytherapy. Methods: An experimental fixture was assembled to position the applicator in a water phantom. Prior to measurement, calibration curves for EBT3 film in water and in solidwater were verified. EBT3 film was placed at different known locations around the applicator in the water tank. A CT scan of the phantom with applicator was performed using clinical protocol. A typical cervical cancer treatment plan was then generated by Oncentra brachytherapy planning system. A dose of 500 cGy was prescribed to point A (2 cm, 2 cm). Locations measured by film included the outer surface of the ring, measurement point A-m (2.2 cm, 2.2 cm), and profiles extending from point A-m parallel to the tandem. Three independent measurements were conducted. The doses recorded by film were carefully analyzed and compared with values calculated by the treatment planning system. Results: Assessment of the EBT3 films indicate that the dose at point A matches the values predicted by the planning system. Dose to the point A-m was 411.5 cGy, and the outer circumferential surface dose of the ring was between 500 and 1150 cGy. It was found that from the point A-m, the dose drops 60% within 4.5 cm on the line parallel to the tandem. The measurement doses agree with the treatment planning system. Conclusion: Use of EBT3 film is feasible for in-water measurements for brachytherapy. A carefully machined apparatus will likely improve measurement accuracy. In a typical plan, our study found that the ring surface dose can be 2.5 times larger than the point A prescription dose. EBT3 film can be used to monitor mucosal dose in brachytherapy treatments.

60 APPLIED LIFE SCIENCES↗

SU-G-201-03: Automation of High Dose Rate Brachytherapy Quality Assurance: Development of a Radioluminescent Detection System for Simultaneous Detection of Activity, Timing, and Positioning

Purpose: Accuracy of positioning, timing and activity is of critical importance for High Dose Rate (HDR) brachytherapy delivery. Respective measurements via film autoradiography, stop-watches and well chambers can be cumbersome, crude or lack dynamic source evaluation capabilities. To address such limitations, a single device radioluminescent detection system enabling automated real-time quantification of activity, position and timing accuracy is presented and experimentally evaluated. Methods: A radioluminescent sheet was fabricated by mixing Gd?O?S:Tb with PDMS and incorporated into a 3D printed device where it was fixated below a CMOS digital camera. An Ir-192 HDR source (VS2000, VariSource iX) with an effective active length of 5 mm was introduced using a 17-gauge stainless steel needle below the sheet. Pixel intensity values for determining activity were taken from an ROI centered on the source location. A calibration curve relating intensity values to activity was generated and used to evaluate automated activity determination with data gathered over 6 weeks. Positioning measurements were performed by integrating images for an entire delivery and fitting peaks to the resulting profile. Timing measurements were performed by evaluating source location and timestamps from individual images. Results: Average predicted activity error over 6 weeks was .35 ± .5%. The distance between four dwell positions was determined by the automated system to be 1.99 ± .02 cm. The result from autoradiography was 2.00 ± .03 cm. The system achieved a time resolution of 10 msec and determined the dwell time to be 1.01 sec ± .02 sec. Conclusion: The system was able to successfully perform automated detection of activity, positioning and timing concurrently under a single setup. Relative to radiochromic and radiographic film-based autoradiography, which can only provide a static evaluation positioning, optical detection of temporary radiation induced luminescence enables dynamic detection of position enabling automated quantification of timing with millisecond accuracy.

60 APPLIED LIFE SCIENCES↗

TU-H-BRA-09: Relationship Between B0 and the Contrast-To-Noise Ratio (CNR) of Tumour to Background for MRI/Radiotherapy Hybrids

Purpose: To investigate the relationship in MRI between B{sub 0} and the contrast-to-noise ratio (CNR) of various tumour/normal tissue pairs. This study is motivated by the current interest in MRI/radiotherapy hybrids, for which multiple magnetic field strengths have been proposed. CNR is the single most important parameter governing the ability of a system to identify a tumour in real time for treatment guidance. The MRI community has long since recognized that the SNR of a well-designed MR system is roughly proportional to B{sub 0}, the polarizing magnetic field. However, the CNR between two tissues is much more complicated - dependent not only on this signal behavior, but also on the different relaxation properties of the tissues. Methods: Experimentally-based models of B{sub 0}-dependant relaxation for various tumour and normal tissues from the literature were used in conjunction with signal equations for MR sequences suitable for rapid realtime imaging to develop field-dependent predictions for CNR. These CNR models were developed for liver, lung, breast, glioma, and kidney tumours for spoiled-gradient echo (SGE) and balanced steady-state free precession (bSSFP) sequences. Results: In all cases there was an improved CNR at lower fields compared to linear dependency. Further, in some tumour sites, the CNR at lower fields was found to be comparable to, or sometimes higher than those at higher fields (i.e. bSSFP CNR for glioma, kidney and liver tumours). Conclusion: Due to the variation of tissue relaxation parameters with field, lower B{sub 0} fields have been shown to perform as well or better (in terms of CNR) than higher fields for some tumour sites. In other sites this effect was less pronounced. It is the complex relationship between CNR and B{sub 0} that leads to greater CNR at 0.5 T for certain tumour types studied here for fast imaging. B. Gino Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta bi-planar linac MR for commercialization)

60 APPLIED LIFE SCIENCES↗

WE-AB-207A-09: Optimization of the Design of a Moving Blocker for Cone-Beam CT Scatter Correction: Experimental Evaluation

Purpose: A moving blocker based strategy has shown promising results for scatter correction in cone-beam computed tomography (CBCT). Different geometry designs and moving speeds of the blocker affect its performance in image reconstruction accuracy. The goal of this work is to optimize the geometric design and moving speed of the moving blocker system through experimental evaluations. Methods: An Elekta Synergy XVI system and an anthropomorphic pelvis phantom CIRS 801-P were used for our experiment. A blocker consisting of lead strips was inserted between the x-ray source and the phantom moving back and forth along rotation axis to measure the scatter signal. Accoriding to our Monte Carlo simulation results, three blockers were used, which have the same lead strip width 3.2mm and different gap between neighboring lead strips, 3.2, 6.4 and 9.6mm. For each blocker, three moving speeds were evaluated, 10, 20 and 30 pixels per projection (on the detector plane). Scatter signal in the unblocked region was estimated by cubic B-spline based interpolation from the blocked region. CBCT image was reconstructed by a total variation (TV) based algebraic iterative reconstruction (ART) algorithm from the partially blocked projection data. Reconstruction accuracy in each condition is quantified as CT number error of region of interest (ROI) by comparing to a CBCT reconstructed image from analytically simulated unblocked and scatter free projection data. Results: Highest reconstruction accuracy is achieved when the blocker width is 3.2 mm, the gap between neighboring lead strips is 9.6 mm and the moving speed is 20 pixels per projection. RMSE of the CT number of ROIs can be reduced from 436 to 27. Conclusions: Image reconstruction accuracy is greatly affected by the geometry design of the blocker. The moving speed does not have a very strong effect on reconstruction result if it is over 20 pixels per projection.

60 APPLIED LIFE SCIENCES↗

Automatic segmentation of the glenohumeral cartilages from magnetic resonance images

Purpose: Magnetic resonance (MR) imaging plays a key role in investigating early degenerative disorders and traumatic injuries of the glenohumeral cartilages. Subtle morphometric and biochemical changes of potential relevance to clinical diagnosis, treatment planning, and evaluation can be assessed from measurements derived from in vivo MR segmentation of the cartilages. However, segmentation of the glenohumeral cartilages, using approaches spanning manual to automated methods, is technically challenging, due to their thin, curved structure and overlapping intensities of surrounding tissues. Automatic segmentation of the glenohumeral cartilages from MR imaging is not at the same level compared to the weight-bearing knee and hip joint cartilages despite the potential applications with respect to clinical investigation of shoulder disorders. In this work, the authors present a fully automated segmentation method for the glenohumeral cartilages using MR images of healthy shoulders. Methods: The method involves automated segmentation of the humerus and scapula bones using 3D active shape models, the extraction of the expected bone–cartilage interface, and cartilage segmentation using a graph-based method. The cartilage segmentation uses localization, patient specific tissue estimation, and a model of the cartilage thickness variation. The accuracy of this method was experimentally validated using a leave-one-out scheme on a database of MR images acquired from 44 asymptomatic subjects with a true fast imaging with steady state precession sequence on a 3 T scanner (Siemens Trio) using a dedicated shoulder coil. The automated results were compared to manual segmentations from two experts (an experienced radiographer and an experienced musculoskeletal anatomist) using the Dice similarity coefficient (DSC) and mean absolute surface distance (MASD) metrics. Results: Accurate and precise bone segmentations were achieved with mean DSC of 0.98 and 0.93 for the humeral head and glenoid fossa, respectively. Mean DSC scores of 0.74 and 0.72 were obtained for the humeral and glenoid cartilage volumes, respectively. The manual interobserver reliability evaluated by DSC was 0.80 ± 0.03 and 0.76 ± 0.04 for the two cartilages, implying that the automated results were within an acceptable 10% difference. The MASD between the automatic and the corresponding manual cartilage segmentations was less than 0.4 mm (previous studies reported mean cartilage thickness of 1.3 mm). Conclusions: This work shows the feasibility of volumetric segmentation and separation of the glenohumeral cartilages from MR images. To their knowledge, this is the first fully automated algorithm for volumetric segmentation of the individual glenohumeral cartilages from MR images. The approach was validated against manual segmentations from experienced analysts. In future work, the approach will be validated on imaging datasets acquired with various MR contrasts in patients.

60 APPLIED LIFE SCIENCES↗

RNAseq analysis of Cellvibrio japonicus during starch utilization differentiates between genes encoding carbohydrate active enzymes controlled by substrate detection or growth rate

ABSTRACT Bacterial utilization of starch is increasingly of interest as the importance and contributions of animal gut microbiomes become more defined. Consequently, identifying and characterizing the bacterial enzymes responsible for the degradation, transport, and metabolism of starch will enable developments in pharmaceutical, biotechnological, and culinary industries searching for novel prebiotics, carrier molecules, and low glycemic index sweeteners. The current challenge is that bacteria proficient at starch utilization often have hundreds of carbohydrate active enzymes, and it is unclear which are essential for starch utilization using only homology-based bioinformatics or computational methods. Complementary experimental data are also needed, especially to understand the regulation of bacterial starch utilization. We have completed an RNAseq analysis of the Gram-negative bacterium Cellvibrio japonicus and found that it has sophisticated regulation that includes substrate sensing and growth rate components for genes that encode starch-degrading enzymes. Among the 22 genes predicted to encode starch-active enzymes, C. japonicus has 10 alpha-amylases, 4 alpha-glucosidases, 2 pullulnases, and 2 cyclomaltodextrin glucanotransferases, 15 of which were up-regulated during exponential growth on starch and 8 up-regulated in stationary phase. Growth analyses with an enzyme secretion deficient mutant of C. japonicus suggested that secreted amylases are essential for this bacterium to degrade starch. Our approach of coupling a physiological growth assay with transcriptomic data provides a platform to identify targets for further genetic or biochemical analysis that can be broadly applied to other starch-utilizing bacteria. IMPORTANCE Understanding the bacterial metabolism of starch is important as this polysaccharide is a ubiquitous ingredient in foods, supplements, and medicines, all of which influence gut microbiome composition and health. Our RNAseq and growth data set provides a valuable resource to those who want to better understand the regulation of starch utilization in Gram-negative bacteria. These data are also useful as they provide an example of how to approach studying a starch-utilizing bacterium that has many putative amylases by coupling transcriptomic data with growth assays to overcome the potential challenges of functional redundancy. The RNAseq data can also be used as a part of larger meta-analyses to compare how C. japonicus regulates carbohydrate active enzymes, or how this bacterium compares to gut microbiome constituents in terms of starch utilization potential.

59 BASIC BIOLOGICAL SCIENCES↗

Small-angle scattering study of Aspergillus awamori glycoprotein glucoamylase

Glucoamylase from fungus Aspergillus awamori is glycoside hydrolase that catalyzes the hydrolysis of α-1,4- and α-1,6-glucosidic bonds in glucose polymers and oligomers. This glycoprotein consists of a catalytic domain and a starch-binding domain connected by an O-glycosylated polypeptide chain. The conformation of the linker, the relative arrangement of the domains, and the structure of the full-length enzyme are unknown. The structure of the recombinant glucoamylase GA1 was studied by molecular modelling and small-angle neutron scattering (SANS) methods. The experimental SANS data provide evidence that glucoamylase exists as a monomer in solution and contains a glycoside component, which makes a substantial contribution to the scattering. The model of full-length glucoamylase, which was calculated without taking into account the effect of glycosylation, is consistent with the experimental data and has a radius of gyration of 33.4 ± 0.6 Å.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Generalized Ginzburg-Landau functional calculations of the structure and energy of the coherent interphase boundaries between austenite and martensite in iron

The earlier-developed methods and experimental data on the phonon spectra and thermodynamics of fcc and bcc iron are used to construct a generalized Ginzburg-Landau functional for microscopic investigations of the austenite-martensite phase transformations in iron. This functional is used to calculate the structure and properties of a plane austenite-martensite interface for arbitrary orientations of this interface at various temperatures. The transformation parameter profiles in the interface region are calculated. The interface width is found to substantially exceed the interatomic distances. The interfacial surface energy is 500-800 erg/cm{sup 2}, depends strongly on the orientation, and has a sharp maximum when the interface is parallel to a close-packed plane.

36 MATERIALS SCIENCE↗

Recoil studies in the reaction of {sup 12}C ions with the enriched isotope {sup 118}Sn

The recoil properties of the product nuclei from the interaction of 2.2 GeV/nucleon {sup 12}C ions from Nuclotron of the Laboratory of High Energies, Joint Institute for Nuclear Research at Dubna with a {sup 118}Sn target have been studied via catcher foils method. The experimental data were analyzed using the mathematical formalism of the standard two-step vector model. The results for {sup 12}C ions are compared with those for deuterons and protons. Three different Los Alamos versions of the Quark-Gluon String Model were used for comparison with our experimental data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reliability of Photonuclear Data: Various Experiments and Evaluations

The well-known problem of reliability of partial photoneutron cross-section data obtained using beams of quasimonoenergetic annihilation photons was discussed. Noticeable disagreements between data from various experiments were analyzed using physical data reliability criteria. The experimentally-theoretical method for evaluating of reaction cross sections satisfied physical criteria was used and new reliable data were obtained for many nuclei. The disagreements between newly evaluated cross sections and data from the IAEA Digital Photonuclear Data Library were discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Small-Angle Neutron Scattering Wave Interference on Ferromagnetic Alloys

The detection conditions and features of direct and scattered neutron wave interference are studied on magnetized Co{sub 67}Fe{sub 31}V{sub 2} alloy slabs. The angular intensity distributions of neutrons passed through a sample are measured for the opposite polarization directions of the initial neutron beam. The sought-for effect that is induced by the magnetic scattering on crystal structure irregularities in specimens manifest itself by different areas of peaks “without neutron spin flip.” The ratio of these areas depends on the thermal treatment mode, sample thickness and strength of the magnetic field applied to the sample. The peaks “with neutron spin flip” are due to the mechanism of neutron wave passage through magnetononcollinear boundaries. The methods for experimental data acquisition and processing are reported as well.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗