Search NASA⌕ Search

SEARCH · Search NASA

Results for “height estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

A 33 yr constancy of the X-ray coronae of AR Lac and eclipse diagnosis of scale height

Extensive X-ray and EUV photometric observations of the eclipsing RS CVn system AR Lac were obtained over the years 1997-2013 with the Chandra X-Ray Observatory Extreme-Ultraviolet Explorer (EUVE). During primary eclipse, High Resolution Camera count rates decrease by ∼40%. A similar minimum is seen during one primary eclipse observed by EUVE but not in others owing to intrinsic source variability. Little evidence for secondary eclipses is present in either the X-ray or EUV data, reminiscent of earlier X-ray and EUV observations. Primary eclipses allow us to estimate the extent of a spherically symmetric corona on the primary G star of about 1.3 R {sub ☉}, or 0.86 R {sub *}, and indicate that the G star is likely brighter than the K component by a factor of 2-5. Brightness changes not attributable to eclipses appear to be dominated by stochastic variability and are generally non-repeating. X-ray and EUV light curves cannot therefore be reliably used to reconstruct the spatial distribution of emission assuming that only eclipses and rotational modulation are at work. Moderate flaring is observed, where count rates increase by up to a factor of three above quiescence. Combined with older ASCA, Einstein, EXOSAT, ROSAT, and BeppoSAX observations, the data show that the level of quiescent coronal emission at X-ray wavelengths has remained remarkably constant over 33 yr, with no sign of variation due to magnetic cycles. Variations in base level X-ray emission seen by Chandra over 13 yr are only ∼10%, while variations back to pioneering Einstein observations in 1980 amount to a maximum of 45% and more typically about 15%.

79 ASTRONOMY AND ASTROPHYSICS↗

A WISER way for simulating the performance of gratings

Soft X-ray monochromators for synchrotron radiation sources have been continuously developed over the years, improving energy resolution and stability. Great effort has been made in improving the surface quality of the optics involved, reaching values permitting diffraction-limited images. Still, one problem has not been solved, nor fully understood, yet: groove placing errors. Nowadays, these are one of the major factors responsible for resolving the power reduction of diffraction-gratings-based X-ray monochromators. Despite decades of use of gratings, there is not yet a universally established method for predicting and simulating the effect of groove placing errors on monochromator performance. This is especially important in the new scenario of high-coherent X-ray sources, i.e. diffraction-limited storage rings and free-electron lasers. To address this problem, in this article an approach based on WISER (Wavefront propagatIon Simulation codE libRary) is presented. WISER is a physical optics simulation package, also available in the user-friendly Orange Synchrotron Radiation Suite – OASYS. Even though it was originally conceived to assess the focusing performance of X-ray mirrors in the presence of height defects, it perfectly simulates the performance of a periodic (or quasi-periodic) structure like a diffraction grating. In this article, the way to use WISER and its application to a specific case, e.g. the design of a monochromator for the upgrade of a beamline at the Advanced Light Source, are shown. A simple rule for estimating how well the grooves are placed on a grating, based on calculation of the Strehl ratio, is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-117: Dose to Organs Outside of CT Scan Range- Monte Carlo and Hybrid Phantom Approach

Purpose: Epidemiological study of second cancer risk for cancer survivors often requires the dose to normal tissues located outside the anatomy covered by radiological imaging, which is usually limited to tumor and organs at risk. We have investigated the feasibility of using whole body computational human phantoms for estimating out-of-field organ doses for patients treated by Intensity Modulated Radiation Therapy (IMRT). Methods: Identical 7-field IMRT prostate plans were performed using X-ray Voxel Monte Carlo (XVMC), a radiotherapy-specific Monte Carlo transport code, on the computed tomography (CT) images of the torso of an adult male patient (175 cm height, 66 kg weight) and an adult male hybrid computational phantom with the equivalent body size. Dose to the liver, right lung, and left lung were calculated and compared. Results: Considerable differences are seen between the doses calculated by XVMC for the patient CT and the hybrid phantom. One major contributing factor is the treatment method, deep inspiration breath hold (DIBH), used for this patient. This leads to significant differences in the organ position relative to the treatment isocenter. The transverse distances from the treatment isocenter to the inferior border of the liver, left lung, and right lung are 19.5cm, 29.5cm, and 30.0cm, respectively for the patient CT, compared with 24.3cm, 36.6cm, and 39.1cm, respectively, for the hybrid phantom. When corrected for the distance, the mean doses calculated using the hybrid phantom are within 28% of those calculated using the patient CT. Conclusion: This study showed that mean dose to the organs located in the missing CT coverage can be reconstructed by using whole body computational human phantoms within reasonable dosimetric uncertainty, however appropriate corrections may be necessary if the patient is treated with a technique that will significantly deform the size or location of the organs relative to the hybrid phantom.

60 APPLIED LIFE SCIENCES↗

Aerosol and Cloud Optical Properties from the ARM Raman Lidars: The Feature Detection and Extinction (RLPROF-FEX) Value-Added Product

Aerosols and their interactions and influence on clouds are among the main sources of uncertainties in radiative direct and indirect forcing (IPCC 2013). Continuous height-resolved measurements of cloud and aerosol optical properties are needed to reduce these uncertainties. Here we describe the Raman Lidar Profiles – Feature detection and Extinction (RLPROF-FEX) Value-Added Product (VAP) derived using Raman lidar data at multiple U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility sites. RLPROF-FEX provides estimates of extinction, backscatter, and depolarization using the algorithm described by Thorsen et al. 2015 and Thorsen and Fu 2015. This document provides a description of the FEX algorithm, its input and output data, and related details about the Raman lidar (RL) system.

54 ENVIRONMENTAL SCIENCES↗

The relationship between the galactic matter distribution, cosmic-ray dynamics, and gamma-ray production

The concept that cosmic-ray density is related to the matter to which cosmic rays are dynamically coupled through magnetic fields on the scale of galactic arm segments is considered with specific reference to gamma-ray astronomy. A model of the galactic-matter and cosmic-ray distributions is developed on the basis of 21-cm radio surveys and recent observations of the 2.6-mm CO emission line by assuming that cosmic rays are galactic in origin, their column density is proportional to the total interstellar-gas column density, their scale height is considerably larger than that of the matter, and the Galaxy is a spiral with an arm/interarm density ratio of about 3 to 1. It is found that there is a good correlation between the observed gamma-ray intensity and that predicted on the basis of essentially complete coupling of cosmic rays to the best estimate of atomic and molecular hydrogen in the Galaxy. Individual maxima observed in gamma-radiation from the central region of the Galaxy are shown to be well correlated with those predicted to result from certain spiral-arm tangents if all the matter is assumed to be modulated in a particular spiral-arm segment pattern.

Kniffen, D. A.↗

Quiet Clean Short-Haul Experimental Engine (QCSEE) acoustic and aerodynamic tests on a scale model over-the-wing thrust reverser and forward thrust nozzle

An acoustic and aerodynamic test program was conducted on a 1/6.25 scale model of the Quiet, Clean, Short-Haul Experimental Engine (QCSEE) forward thrust over-the-wing (OTW) nozzle and OTW thrust reverser. In reverse thrust, the effect of reverser geometry was studied by parametric variations in blocker spacing, blocker height, lip angle, and lip length. Forward thrust nozzle tests determined the jet noise levels of the cruise and takeoff nozzles, the effect of opening side doors to achieve takeoff thrust, and scrubbing noise of the cruise and takeoff jet on a simulated wing surface. Velocity profiles are presented for both forward and reverse thrust nozzles. An estimate of the reverse thrust was made utilizing the measured centerline turning angle.

Stimpert, D. L.↗

The large-scale distribution of molecular gas in the first Galactic quadrant

The emission parameters for the molecular component of the interstellar medium are determined throughout the first Galactic quadrant. Face-on maps of the peak midplane molecular density, scale height, and offset from b = 0 deg with roughly 300 pc resolution are presented. These maps are compared with the distribution of cataloged H II regions to test whether both species trace the same Galactic locations. The properties of the spiral (or ringlike) arms are deduced from the derived images and pitch-angle upper limits are estimated. The H II regions are strongly correlated with the dense molecular rings.

Clemens, Dan P.↗

Geostationary satellite position determination for common-view two-way time transfer measurements

In common-view two-way time transfer, each earth station receives an unwanted return signal from its own transmission as well as the desired signal from the other earth station. National Institute of Standards and Technology (NIST), the National Research Council (NRC), and the U.S. Naval Observatory (USNO) have been cooperating in a three-corner common-view two-way time transfer experiment. Some systematic effects are known to depend on the position of the satellite (Sagnac effect and the cross-correlation pulling of the pseudo-random codes). A method is presented for deriving accurate satellite ranges from each of three stations doing common-view two-way satellite time transfer measurements, when one (and only one) station also takes ranging measurements on its 'unwanted return signal' for a brief period. The method is applied to determine the variations in position of the satellite used over the course of the NIST/NRC/USNO SBS-3 experiment, with ranging data taken at NRC, where no additional hardware was required to automate the process. The fit and extrapolation which are employed in this method have an estimated precision of 2 m. If the delays of SBS-3 satellite KU band transponder and earth station equipment were measured accurately as well as the tropospheric refractions were well modeled and corrected, we would expect a ranging accuracy of 2.5 m and satellite positioning accuracy would be 200 m (latitude) 50 m (longitude) and 20 m (height above ellipsoid).

Zhuang, Qixiang↗

Large-scale isentropic mixing properties of the Antarctic polar vortex from analyzed winds

Winds derived from analyzed geopotential height fields are used to study quasi-horizontal mixing by the large-scale flow in the lower stratosphere during austral spring. This is the period when the Antarctic ozone hole appears and disappears. Trajectories are computed for large ensembles of particles initially inside and outside the main polar vortex. Mixing and transport are diagnosed through estimates of finite time Lyapunov exponents and Lagrangian dispersion statistics of the tracer trajectories. At 450 K and above prior to the vortex breakdown: Lyapunov exponents are a factor of 2 smaller inside the vortex than outside; diffusion coefficients are an order of magnitude smaller inside than outside the vortex; and the trajectories reveal little exchange of air across the vortex boundary. At lower levels (425 and 400 K) mixing is greater, and there is substantial exchange of air across the vortex boundary. In some years there are large wave events that expel small amounts of vortex air into the mid-latitudes. At the end of the spring season during the vortex breakdown there is rapid mixing of air across the vortex boundary, which is evident in the mixing diagnostics and the tracer trajectories.

Bowman, Kenneth P.↗

Assimilation of TOPEX Sea Level Measurements with a Reduced-Gravity, Shallow Water Model of the Tropical Pacific Ocean

Sea surface height variability measured by TOPEX is analyzed in the tropical Pacific Ocean by way of assimilation into a wind-driven, reduced-gravity, shallow water model using an approximate Kalman filter and smoother. The analysis results in an optimal fit of the dynamic model to the observations, providing it dynamically consistent interpolation of sea level and estimation of the circulation. Nearly 80% of the expected signal variance is accounted for by the model within 20 deg of the equator, and estimation uncertainty is substantially reduced by the voluminous observation. Notable features resolved by the analysis include seasonal changes associated with the North Equatorial Countercurrent and equatorial Kelvin and Rossby waves. Significant discrepancies are also found between the estimate and TOPEX measurements, especially near the eastern boundary. Improvements in the estimate made by the assimilation are validated by comparisons with independent tide gauge and current meter observations. The employed filter and smoother are based on approximately computed estimation error covariance matrices, utilizing a spatial transformation and an symptotic approximation. The analysis demonstrates the practical utility of a quasi-optimal filter and smoother.

Fukumori, Ichiro↗

Soot Aerosol Properties in Laminar Soot-Emitting Microgravity Nonpremixed Flames

The spatial distributions and morphological properties of the soot aerosol are examined experimentally in a series of 0-g laminar gas-jet nonpremixed flames. The methodology deploys round jet diffusion flames of nitrogen-diluted acetylene fuel burning in quiescent air at atmospheric pressure. Full-field laser-light extinction is utilized to determine transient soot spatial distributions within the flames. Thermophoretic sampling is employed in conjunction with transmission electron microscopy to define soot microstructure within the soot-emitting 0-g flames. The microgravity tests indicate that the 0-g flames attain a quasi-steady state roughly 0.7 s after ignition, and sustain their annular structure even beyond their luminous flame tip. The measured peak soot volume fractions show a complex dependence on burner exit conditions, and decrease in a nonlinear fashion with decreasing characteristic flow residence times. Fuel preheat by approximately 140 K appears to accelerate the formation of soot near the flame axis via enhanced fuel pyrolysis rates. The increased soot presence caused by the elevated fuel injection temperatures triggers higher flame radiative losses, which may account for the premature suppression of soot growth observed along the annular region of preheated-fuel flames. Electron micrographs of soot aggregates collected in 0-g reveal the presence of soot precursor particles near the symmetry axis at midflame height, The observations also verify that soot primary particle sizes are nearly uniform among aggregates present at the same flame location, but vary considerably with radius at a fixed distance from the burner. The maximum primary size in 0-g is found to be by 40% larger than in 1-g, under the same burner exit conditions. Estimates of the number concentration of primary particles and surface area of soot particulate phase per unit volume of the combustion gases are also made for selected in-flame locations.

Konsur, Bogdan↗

Reynolds-Averaged Turbulence Model Assessment for a Highly Back-Pressured Isolator Flowfield

The use of computational fluid dynamics in scramjet engine component development is widespread in the existing literature. Unfortunately, the quantification of model-form uncertainties is rarely addressed with anything other than sensitivity studies, requiring that the computational results be intimately tied to and calibrated against existing test data. This practice must be replaced with a formal uncertainty quantification process for computational fluid dynamics to play an expanded role in the system design, development, and flight certification process. Due to ground test facility limitations, this expanded role is believed to be a requirement by some in the test and evaluation community if scramjet engines are to be given serious consideration as a viable propulsion device. An effort has been initiated at the NASA Langley Research Center to validate several turbulence closure models used for Reynolds-averaged simulations of scramjet isolator flows. The turbulence models considered were the Menter BSL, Menter SST, Wilcox 1998, Wilcox 2006, and the Gatski-Speziale explicit algebraic Reynolds stress models. The simulations were carried out using the VULCAN computational fluid dynamics package developed at the NASA Langley Research Center. A procedure to quantify the numerical errors was developed to account for discretization errors in the validation process. This procedure utilized the grid convergence index defined by Roache as a bounding estimate for the numerical error. The validation data was collected from a mechanically back-pressured constant area (1 2 inch) isolator model with an isolator entrance Mach number of 2.5. As expected, the model-form uncertainty was substantial for the shock-dominated, massively separated flowfield within the isolator as evidenced by a 6 duct height variation in shock train length depending on the turbulence model employed. Generally speaking, the turbulence models that did not include an explicit stress limiter more closely matched the measured surface pressures. This observation is somewhat surprising, given that stress-limiting models have generally been developed to better predict shock-separated flows. All of the models considered also failed to properly predict the shape and extent of the separated flow region caused by the shock boundary layer interactions. However, the best performing models were able to predict the isolator shock train length (an important metric for isolator operability margin) to within 1 isolator duct height.

Baurle, Robert A.↗

Respirable Release Fraction Measurement Chamber (RRFMC) - 18321

The Respirable Release Fraction Measurement Chamber (RRFMC) is designed to hoist a container to a predetermined height, drop it, and then utilize aerosol particle counters to measure the mass of powder that is released from failed containers. The RRFMC hoist mechanism is located inside an airtight (6.1 m high) steel enclosure that isolates the released test aerosol from the surrounding lab room environment. Accurate measurement of the released test powder is necessary for estimating the total released mass of material. Cerium oxide will be used as a surrogate for plutonium oxide. The range of the aerodynamic diameter of cerium oxide test powder was characterized both by cascade impaction and aerodynamic sizing. The scope of this paper includes the physical parameters required for accurately measuring the total mass of released powder, the fabrication of the tower, various strategies to optimize concentration sampling, and developing methods to accurately measure the respirable fraction, airborne release fraction, and the damage ratio. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of MMOD Impact on STS-115 Shuttle Payload Bay Door Radiator

The Orbiter radiator system consists of eight individual 4.6 m x 3.2 m panels located with four on each payload bay door. Forward panels #1 and #2 are 2.3 cm thick while the aft panels #3 and #4 have a smaller overall thickness of 1.3 cm. The honeycomb radiator panels consist of 0.028 cm thick Aluminum 2024-T81 facesheets and Al5056-H39 cores. The face-sheets are topped with 0.005 in. (0.127 mm) silver-Teflon tape. The radiators are located on the inside of the shuttle payload bay doors, which are closed during ascent and reentry, limiting damage to the on-orbit portion of the mission. Post-flight inspections at the Kennedy Space Center (KSC) following the STS-115 mission revealed a large micrometeoroid/orbital debris (MMOD) impact near the hinge line on the #4 starboard payload bay door radiator panel. The features of this impact make it the largest ever recorded on an orbiter payload bay door radiator. The general location of the damage site and the adjacent radiator panels can be seen in Figure 2. Initial measurements of the defect indicated that the hole in the facesheet was 0.108 in. (2.74 mm) in diameter. Figure 3 shows an image of the front side damage. Subsequent observations revealed exit damage on the rear facesheet. Impact damage features on the rear facesheet included a 0.03 in. diameter hole (0.76 mm), a approx.0.05 in. tall bulge (approx.1.3 mm), and a larger approx.0.2 in. tall bulge (approx.5.1 mm) that exhibited a crack over 0.27 in. (6.8 mm) long. A large approx.1 in. (25 mm) diameter region of the honeycomb core was also damaged. Refer to Figure 4 for an image of the backside damage to the panel. No damage was found on thermal blankets or payload bay door structure under the radiator panel. Figure 5 shows the front facesheet with the thermal tape removed. Ultrasound examination indicated a maximum facesheet debond extent of approximately 1 in. (25 mm) from the entry hole. X-ray examinations revealed damage to an estimated 31 honeycomb cells with an extent of 0.85 in. x 1.1 in. (21.6 x 27.9 mm). Pieces of the radiator at and surrounding the impact site were recovered during the repair procedures at KSC. They included the thermal tape, front facesheet, honeycomb core, and rear facesheet. These articles were examined at JSC using a scanning electron microscope (SEM) with an energy dispersive x-ray spectrometer (EDS). Figure 6 shows SEM images of the entry hole in the facesheet. The asymmetric height of the lip may be attributed to projectile shape and impact angle. Numerous instances of a glass-fiber organic matrix composite were observed in the facesheet tape sample. The fibers were approximately 10 micrometers in diameter and variable lengths. EDS analysis indicated a composition of Mg, Ca, Al, Si, and O. Figures 7 and 8 present images of the fiber bundles, which were believed to be circuit board material based on similarity in fiber diameter, orientation, consistency, and composition. A test program was initiated in an attempt to simulate the observed damage to the radiator facesheet and honeycomb. Twelve test shots were performed using projectiles cut from a 1.6 mm thick fiberglass circuit board substrate panel. Results from test HITF07017, shown in figures 9 and 10, correlates with the observed impact features reasonably well. The test was performed at 4.14 km/sec with an impact angle of 45 degrees using a cylindrical projectile with a diameter and length of 1.25 mm. The fiberglass circuit board material had a density of 1.65 g/cu cm, giving a projectile mass of 2.53 mg. An analysis was performed using the Bumper code to estimate the probability of impact to the shuttle from a 1.25 mm diameter particle. Table 1 shows a 1.6% chance (impact odds = 1 in 62) of a 1.25 mm or larger MMOD impact on the radiators of the vehicle during a typical ISS mission. There is a 0.4% chance (impact odds = 1 in 260) that a 1.25 mm or larger MMOD particle would impact the RCC wing leading edge and nose cap during a typical miion. Figure 11 illustrates the vulnerable areas of the wing leading edge reinforced carbon-carbon (RCC), an area of the vehicle that is very sensitive to impact damage. The highlighted red, orange, yellow, and light green areas would be expected to experience critical damage if impacted by an OD particle such as the one that hit the RH4 radiator panel on STS-115.

Hyde, J.↗

Fusion of AIRSAR and TM Data for Parameter Classification and Estimation in Dense and Hilly Forests

The expanded remotely sensed data space consisting of coincident radar backscatter and optical reflectance data provides for a more complete description of the Earth surface. This is especially useful where many parameters are needed to describe a certain scene, such as in the presence of dense and complex-structured vegetation or where there is considerable underlying topography. The goal of this paper is to use a combination of radar and optical data to develop a methodology for parameter classification for dense and hilly forests, and further, class-specific parameter estimation. The area to be used in this study is the H. J. Andrews Forest in Oregon, one of the Long-Term Ecological Research (LTER) sites in the US. This area consists of various dense old-growth conifer stands, and contains significant topographic relief. The Andrews forest has been the subject of many ecological studies over several decades, resulting in an abundance of ground measurements. Recently, biomass and leaf-area index (LAI) values for approximately 30 reference stands have also become available which span a large range of those parameters. The remote sensing data types to be used are the C-, L-, and P-band polarimetric radar data from the JPL airborne SAR (AIRSAR), the C-band single-polarization data from the JPL topographic SAR (TOPSAR), and the Thematic Mapper (TM) data from Landsat, all acquired in late April 1998. The total number of useful independent data channels from the AIRSAR is 15 (three frequencies, each with three unique polarizations and amplitude and phase of the like-polarized correlation), from the TOPSAR is 2 (amplitude and phase of the interferometric correlation), and from the TM is 6 (the thermal band is not used). The range pixel spacing of the AIRSAR is 3.3m for C- and L-bands and 6.6m for P-band. The TOPSAR pixel spacing is 10m, and the TM pixel size is 30m. To achieve parameter classification, first a number of parameters are defined which are of interest to ecologists for forest process modeling. These parameters include total biomass, leaf biomass, LAI, and tree height. The remote sensing data from radar and TM are used to formulate a multivariate analysis problem given the ground measurements of the parameters. Each class of each parameter is defined by a probability density function (pdf), the spread of which defines the range of that class. High classification accuracy results from situations in which little overlap occurs between pdfs. Classification results provide the basis for the future work of class-specific parameter estimation using radar and optical data. This work was performed in part by the Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA, and in part by the NASA Ames Research Center, Moffett Field, CA, both under contract from the National Aeronautics and Space Administration.

Moghaddam, Mahta↗

Pressurized subsampling system for pressured gas-hydrate-bearing sediment: Microscale imaging using X-ray computed tomography

A pressurized subsampling system was developed for pressured gas hydrate (GH)-bearing sediments, which have been stored under pressure. The system subsamples small amounts of GH sediments from cores (approximately 50 mm in diameter and 300 mm in height) without pressure release to atmospheric conditions. The maximum size of the subsamples is 12.5 mm in diameter and 20 mm in height. Moreover, our system transfers the subsample into a pressure vessel, and seals the pressure vessel by screwing in a plug under hydraulic pressure conditions. In this study, we demonstrated pressurized subsampling from artificial xenon-hydrate sediments and nondestructive microscale imaging of the subsample, using a microfocus X-ray computed tomography (CT) system. In addition, we estimated porosity and hydrate saturation from two-dimensional X-ray CT images of the subsamples.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The equatorial airglow and the ionospheric geomagnetic anomaly

OGO D observations of OI (6300A) emissions reveal a global pattern in the equatorial airglow undetected from the ground-based observations. The post sunset emission rate of OI is generally asymmetrical with respect to the geomagnetic equator and shows no apparent correlation with the ultraviolet airglow (OI 1304 and 1356A) and F region electron density measured simultaneously from the same spacecraft. Both the ultraviolet airglow and the ion density measured in the altitude region of 450 km follow similar latitudinal variations and exhibit properties of the equatorial ionospheric anomaly. The asymmetry in OI emission can be attributed to the asymmetry in the height of the F 2 maximum inferred from the height of the maximum emission. From correlative studies of the airglow and the ionospheric measurements, the mechanisms for the ultraviolet and the 6300A emission are discussed in terms of the processes involving radiative and dissociative recombinations. A relationship between molecular oxygen density and the integrated OI emission rate is derived and the feasibility of using this relationship for estimating O2 density is discussed.

Chandra, S.↗

Least squares collocation applied to local gravimetric solutions from satellite gravity gradiometry data

An autonomous spaceborne gravity gradiometer mission is being considered as a post Geopotential Research Mission project. The introduction of satellite diometry data to geodesy is expected to improve solid earth gravity models. The possibility of utilizing gradiometer data for the determination of pertinent gravimetric quantities on a local basis is explored. The analytical technique of least squares collocation is investigated for its usefulness in local solutions of this type. It is assumed, in the error analysis, that the vertical gravity gradient component of the gradient tensor is used as the raw data signal from which the corresponding reference gradients are removed to create the centered observations required in the collocation solution. The reference gradients are computed from a high degree and order geopotential model. The solution can be made in terms of mean or point gravity anomalies, height anomalies, or other useful gravimetric quantities depending on the choice of covariance types. Selected for this study were 30 x 30 foot mean gravity and height anomalies. Existing software and new software are utilized to implement the collocation technique. It was determined that satellite gradiometry data at an altitude of 200 km can be used successfully for the determination of 30 x 30 foot mean gravity anomalies to an accuracy of 9.2 mgal from this algorithm. It is shown that the resulting accuracy estimates are sensitive to gravity model coefficient uncertainties, data reduction assumptions and satellite mission parameters.

Robbins, J. W.↗