Search NASA⌕ Search

SEARCH · Search NASA

Results for “human error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Hypofractionation Results in Reduced Tumor Cell Kill Compared to Conventional Fractionation for Tumors With Regions of Hypoxia

Purpose: Tumor hypoxia has been observed in many human cancers and is associated with treatment failure in radiation therapy. The purpose of this study is to quantify the effect of different radiation fractionation schemes on tumor cell killing, assuming a realistic distribution of tumor oxygenation. Methods and Materials: A probability density function for the partial pressure of oxygen in a tumor cell population is quantified as a function of radial distance from the capillary wall. Corresponding hypoxia reduction factors for cell killing are determined. The surviving fraction of a tumor consisting of maximally resistant cells, cells at intermediate levels of hypoxia, and normoxic cells is calculated as a function of dose per fraction for an equivalent tumor biological effective dose under normoxic conditions. Results: Increasing hypoxia as a function of distance from blood vessels results in a decrease in tumor cell killing for a typical radiotherapy fractionation scheme by a factor of 10{sup 5} over a distance of 130 {mu}m. For head-and-neck cancer and prostate cancer, the fraction of tumor clonogens killed over a full treatment course decreases by up to a factor of {approx}10{sup 3} as the dose per fraction is increased from 2 to 24 Gy and from 2 to 18 Gy, respectively. Conclusions: Hypofractionation of a radiotherapy regimen can result in a significant decrease in tumor cell killing compared to standard fractionation as a result of tumor hypoxia. There is a potential for large errors when calculating alternate fractionations using formalisms that do not account for tumor hypoxia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The development and verification of a highly accurate collision prediction model for automated noncoplanar plan delivery

Purpose: Significant dosimetric benefits had been previously demonstrated in highly noncoplanar treatment plans. In this study, the authors developed and verified an individualized collision model for the purpose of delivering highly noncoplanar radiotherapy and tested the feasibility of total delivery automation with Varian TrueBeam developer mode. Methods: A hand-held 3D scanner was used to capture the surfaces of an anthropomorphic phantom and a human subject, which were positioned with a computer-aided design model of a TrueBeam machine to create a detailed virtual geometrical collision model. The collision model included gantry, collimator, and couch motion degrees of freedom. The accuracy of the 3D scanner was validated by scanning a rigid cubical phantom with known dimensions. The collision model was then validated by generating 300 linear accelerator orientations corresponding to 300 gantry-to-couch and gantry-to-phantom distances, and comparing the corresponding distance measurements to their corresponding models. The linear accelerator orientations reflected uniformly sampled noncoplanar beam angles to the head, lung, and prostate. The distance discrepancies between measurements on the physical and virtual systems were used to estimate treatment-site-specific safety buffer distances with 0.1%, 0.01%, and 0.001% probability of collision between the gantry and couch or phantom. Plans containing 20 noncoplanar beams to the brain, lung, and prostate optimized via an in-house noncoplanar radiotherapy platform were converted into XML script for automated delivery and the entire delivery was recorded and timed to demonstrate the feasibility of automated delivery. Results: The 3D scanner measured the dimension of the 14 cm cubic phantom within 0.5 mm. The maximal absolute discrepancy between machine and model measurements for gantry-to-couch and gantry-to-phantom was 0.95 and 2.97 cm, respectively. The reduced accuracy of gantry-to-phantom measurements was attributed to phantom setup errors due to the slightly deformable and flexible phantom extremities. The estimated site-specific safety buffer distance with 0.001% probability of collision for (gantry-to-couch, gantry-to-phantom) was (1.23 cm, 3.35 cm), (1.01 cm, 3.99 cm), and (2.19 cm, 5.73 cm) for treatment to the head, lung, and prostate, respectively. Automated delivery to all three treatment sites was completed in 15 min and collision free using a digital Linac. Conclusions: An individualized collision prediction model for the purpose of noncoplanar beam delivery was developed and verified. With the model, the study has demonstrated the feasibility of predicting deliverable beams for an individual patient and then guiding fully automated noncoplanar treatment delivery. This work motivates development of clinical workflows and quality assurance procedures to allow more extensive use and automation of noncoplanar beam geometries.

60 APPLIED LIFE SCIENCES↗

Regulatory Decision-Making Process Using 'Weight of Evidence: An Evidence Integration Approach' by the State of Washington at the Hanford Site - 20163

Performance Assessment and Environmental Impact Statement Modeling, Human and Ecological Risk Assessments are the tools used by the Washington State Department of Ecology (Ecology) to make regulatory decisions for permitting and cleanup. These efforts all inherently have large amounts of uncertainty no matter how many alternative approaches are attempted. Professional feedback from tribal governments, stakeholders, federal and state regulators, the public and independent peer review groups are taken into account in this process of informed decision making. The process also includes full evaluation of the comments and the associated reviews made by the various peer review groups such as the Low -Level Waste Disposal Facility Federal Review Group (DOE order 435.1) and the Nuclear Regulatory Commission (NRC). The evolution of technology has produced quicker and more efficient fate and transport modeling tools with related quantification of uncertainties and their significance. Groundwater and vadose zone models have been expanded across the entire Hanford site. Many of the technical approaches identified in the Washington State Regulations are updated using current knowledge to better understand the complexities of the Hanford Site using the latest state of the art tools for risk assessment and modeling. More emphasis and time are directed on defining uncertainty and then managing the uncertainty. One added tool is to run sensitivity cases based on informed decision making. The weight of evidence approach considers all relevant information in an integrative assessment that takes into account the kinds of evidence available, the quality and quantity, the uncertainty and error associated with each type, and how they fit together. Evidence of integration involves looking at systematic reviews and evaluating their strengths and weaknesses. In conclusion, Ecology, Washington State's lead regulatory agency at the Hanford site, has had to modify its site closure approach compared to the rest of the state. A more holistic approach dealing with the Hanford site as an integrated system has evolved leading to a defensible informed approach for regulatory closure decisions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Work and Fatigue Characteristics of Unsuited and Suited Humans During Isolated, Isokinetic Joint Motions

The effects of a pressurized suit on human performance were investigated. The suit is known as an Extra-vehicular Mobility Unit (EMU) and is worn by astronauts while working outside of their space craft in low earth orbit. Isolated isokinetic joint torques of three female and three male subjects (all experienced users of the suit) were measured while working at 100% and 80% of their maximum voluntary torque (MVT). It was found that the average decrease in the total amount of work done when the subjects were wearing the EMU was 48% and 41% while working at 100% and 80% MVT, respectively. There is a clear relationship between the MVT and the time and amount of work done until fatigue. In general the stronger joints took longer to fatigue and did more work than the weaker joints. However, it is not clear which joints are most affected by the EMU suit in terms of the amount of work done. The average amount of total work done increased by 5.2% and 20.4% for the unsuited and suited cases, respectively, when the subject went from working at 100% to 80% MVT. Also, the average time to fatigue increased by 9.2% and 25.6% for the unsuited and suited cases, respectively, when the subjects went from working at 100% to 80% MVT. The EMU also decreased the joint range of motion. It was also found that the experimentally measured torque decay could be predicted by a logarithmic equation. The absolute average error in the predictions was found to be 18.3% and 18.9% for the unsuited and suited subject, respectively, working at 100% MVT, and 22.5% and 18.8% for the unsuited and suited subject, respectively, working at 80% MVT. These results could be very useful in the design of future EMU suits, and planning of Extra-Vehicular Activit). (EVA) for the upcoming International Space Station assembly operations.

Gonzalez, L. Javier↗

A Prognostics Framework Development for Swarm Satellite Formations

Prognostics is the science of predicting the failure(s) of a component or a system and understanding how the performance will change in the event of a failure or degradation mechanism. With accurate predictions of possible failures, autonomous mitigative actions can be taken to correct/repair any issues or alert human operators of a failure threshold exceedance requiring condition-based maintenance. Although there is extensive research on failure predictions for a component or a system, there are significantly more opportunities to foray into failure predictions and prognostics for a system of systems such as an airspace consisting of multiple aircraft, a fleet of unmanned aerial vehicles, and a swarm of intelligent satellite systems. Failure prediction and mitigation are particularly important in autonomous systems such as satellite swarm systems that need effective resource management and minimal human interactions. Based on NASA's decadal survey, there is a clear need to prioritize the development of satellite swarm technology for studies of space physics and Earth science. The science community will propose future missions that return in-situ measurements from a 3-D (three-dimensional) volume of space, with relative spacecraft motion and inter-satellite baselines controlled according to the mission objectives. For such multi-spacecraft missions, it is required that ground operations resources do not scale with the number of satellites, thus compromising the swarm or leading to inefficiencies in resource allocation. Swarms of tens or hundreds of small satellites will require autonomy in attitude control, navigation and failure. Although significant research has been conducted in the areas of autonomous formation flying algorithms, less attention has been given to the development of resilient systems robust to failures.The focus of this research paper is the integration of model-based prognostics into the swarm dynamics control and decision-making algorithms. We simulate swarm management strategies for a subsystem failure to demonstrate the importance of failure predictions by comparing two cases: (i) no health information is provided to the system and utilized in the decision-making process and (2) system health information is obtained using prognostics and employed by the control system. One example scenario presented is for the GPS (Global Positioning System) system of an individual satellite to perform off-nominally due to increasing estimated error. In this scenario, the keep-out zone for that satellite would become more conservative, thereby decreasing the risk of collision. This is achieved via tuning the individual artificial repulsive functions assigned to each satellite.This paper is structured as follows. First we provide an overview of current swarm technology development, where we specifically use the term swarm to define multiple satellites flying in formation in similar orbits, with cross-link communication and station-keeping capabilities. Second, we give an introduction to the Swarm Orbital Dynamics Advisor (SODA), a tool that accepts high-level configuration commands and provides the orbital maneuvers required to achieve the prescribed formation configuration. Third, we provide the details of the model-based prognostics algorithm implementation in SODA. Finally, we present different case studies for potential component/subsystem failures and the swarm responses based with and without failure prediction information.

prognostics↗

Issues for bringing digital libraries into public use

In much the same way that the field of artificial intelligence produced a cult which fervently believed that computers would soon think like human beings, the existence of electronic books has resurrected the paperless society as a utopian vision to some, an apocalyptic horror to others. In this essay we have attempted to provide realistic notions of what digital libraries are likely to become if they are a popular success. E-books are capable of subsuming most of the media we use today and have the potential for added functionality by being interactive. The environmental impact of having millions more computers will be offset to some degree, perhaps even exceeded, by the fact that televisions, stereos, VCR's, CD players, newspapers, magazines, and books will become part of the computer system or be made redundant. On the whole, large-scale use of digital libraries is likely to be a winning proposition. Whether or not this comes to pass depends on the directions taken by today's researchers and software developers. By involving the public, the effort being put into digital libraries can be leveraged into something which is big enough to make a real change for the better. If digital libraries remain the exclusive property of government, universities, and large research firms, then large parts of the world will remain without digital libraries for years to come, just as they have remained without digital phone service for far too long. If software companies try to scuttle the project by patenting crucial algorithms and using proprietary data formats, all of us will suffer. Let us reverse the errors of the past and create a truly open digital library system.

Flater, David W.↗

Supervised detection of anomalous light curves in massive astronomical catalogs

The development of synoptic sky surveys has led to a massive amount of data for which resources needed for analysis are beyond human capabilities. In order to process this information and to extract all possible knowledge, machine learning techniques become necessary. Here we present a new methodology to automatically discover unknown variable objects in large astronomical catalogs. With the aim of taking full advantage of all information we have about known objects, our method is based on a supervised algorithm. In particular, we train a random forest classifier using known variability classes of objects and obtain votes for each of the objects in the training set. We then model this voting distribution with a Bayesian network and obtain the joint voting distribution among the training objects. Consequently, an unknown object is considered as an outlier insofar it has a low joint probability. By leaving out one of the classes on the training set, we perform a validity test and show that when the random forest classifier attempts to classify unknown light curves (the class left out), it votes with an unusual distribution among the classes. This rare voting is detected by the Bayesian network and expressed as a low joint probability. Our method is suitable for exploring massive data sets given that the training process is performed offline. We tested our algorithm on 20 million light curves from the MACHO catalog and generated a list of anomalous candidates. After analysis, we divided the candidates into two main classes of outliers: artifacts and intrinsic outliers. Artifacts were principally due to air mass variation, seasonal variation, bad calibration, or instrumental errors and were consequently removed from our outlier list and added to the training set. After retraining, we selected about 4000 objects, which we passed to a post-analysis stage by performing a cross-match with all publicly available catalogs. Within these candidates we identified certain known but rare objects such as eclipsing Cepheids, blue variables, cataclysmic variables, and X-ray sources. For some outliers there was no additional information. Among them we identified three unknown variability types and a few individual outliers that will be followed up in order to perform a deeper analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Introducing and Evaluating the Climate Hazards Center IMERG with Stations (CHIMES) Timely Station-Enhanced Integrated Multisatellite Retrievals for Global Precipitation Measurement

As human exposure to hydroclimatic extremes increase and the number of in situ precipitation observations declines, precipitation estimates, such as those provided by the Integrated Multisatellite Retrievals for Global Precipitation Measurement (GPM) (IMERG) mission, provide a critical source of information. Here, we present a new gauge-enhanced dataset [the Climate Hazards Center IMERG with Stations (CHIMES)] designed to support global crop and hydrologic modeling and monitoring. CHIMES enhances the IMERG Late Run product using an updated Climate Hazards Center (CHC) high-resolution climatology (CHPclim) and low-latency rain gauge observations. CHPclim differs from other products because it incorporates long-term averages of satellite precipitation, which increases CHPclim ’s fidelity in data-sparse areas with complex terrain. This fidelity translates into performance increases in unbiased IMERGlate data, which we refer to as CHIME. This is augmented with gauge observations to produce CHIMES. The CHC’s curated rain gauge archive contains valuable contributions from many countries. There are two versions of CHIMES: preliminary and final. The final product has more copious and better-curated station data. Every pentad and month, bias-adjusted IMERGlate fields are combined with gauge observations to create pentadal and monthly CHIMESprelim and CHIMESfinal. Comparisons with pentadal, high-quality gridded station data show that IMERG late performs well (r = 0.75), but has some systematic biases which can be reduced. Monthly cross-validation results indicate that unbiasing increases the variance explained from 50% to 63% and decreases the mean absolute error from 48 to 39 mm month −1. Gauge enhancement then increases the variance explained to 75%, reducing the mean absolute error to 27 mm month −1.

Chris C funk↗

A Grid Intensity Map-Based Source Model for Monte Carlo Modeling of IMRT Field Irradiation - Paper 5

An accurate source model is important for TPS (Treatment Planning System) dose calculation and verification, especially for IMRT (Intensity Modulated Radiotherapy) irregular and inhomogeneous fields. Monte Carlo simulation is the most accurate way to calculate dose distributions in the heterogeneous media like human bodies. A full radiotherapy modeling generally includes Linac modeling and phantom dose calculation. Full Linac modeling is very time-consuming and requires highly detailed knowledge of the accelerator composition and structure, however, which is very difficult to obtain for commercial interests. Often all relevant parameters are not known with sufficient accuracy, and thus a time-consuming tuning of e.g. the electron beam spot size and energy must be performed. A multiple source model (MSM) regards particles coming from different parts of an accelerator as if they are coming from different virtual sources. MSM uses a set of virtual sources representing the treatment beam (e.g. primary photons, head scatter, electron contamination) by a set of analytic functions or histograms with parameters derived from dosimetric measurements or a full MC simulation. Tillikainen et al built a three sub-source model by matching with measurement data using an automatic process to optimize the free model parameters for a Varian 2100 C/D accelerator. Lin et al have built a convenient five-photon-sub-source model for Varian 2300C 6 MV-X beam based on Monte Carlo simulated Linac for ARTS (Accurate Radiotherapy System). The particle generation of MSM is very fast compared to full Linac simulation, and its sampling efficiency is not limited by the size of the phase space file (PSF). However, generally MSM is generated based on regular field PSF and needs an irregular component to form the beam shape meanwhile apt to bringing error Linac modeling and MSM producing from PSF analysis actually both are multi-freedom optimization process by adjusting several parameters (e.g. electron energy and angular divergence). Linac modeling adjusts its parameters from the beginning of electron hitting target through all components to fit the simulation to the measurement. MSM tunes its PSF-derived parameters by optimizing to minimize the deviations between the simulation and the measurement. Since the full Linac modeling and the MSM model both need to fine tune their parameters to match the simulation to the measurement, and sometimes maybe offsets the real accelerator for its multi-parameter optimization process. So, why not fine tune directly all source model parameters just behind all Linac components to fit the simulation to the measurement? A grid intensity-based surface source model was suggested here, which assumed the particle emitting from the bottom surface of Linac last beam trimmer MLC (Multi Leaf Collimator). The particle emitting position is sampled on the grid intensity map optimized by TPS, and the particle weight is adjusted by its original grid intensity. This source model not only takes advantage of the Monte Carlo method in the heterogeneous media, but also avoids effectively the transportation speed shortcoming of Monte Carlo simulation through Linac components. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Strategic Analysis of Complex Security Scenarios

Many advanced technical tools are available to prevent attacks on national infrastructure. Nevertheless, while traditional analyses of security problems have succeeded in producing good technical solutions, they have often ignored the human factor integral to these problems. Human attackers (who may be individuals or state-level attackers) expend substantial effort to breach security because they have the incentive for doing so. People involved in implementing security follow individual incentives, which need not align with global security concerns; consequently, desired security solutions are often implemented poorly, or not at all. This complex interplay between individual incentives and global (organizational and/or national) goals can be modeled and analyzed using game theoretic techniques. By analyzing not only what is possible, but also what is motivated, a holistic approach to security problems can be developed, informing policy and providing tools to policy makers. We study game theoretic models that unify several current incentive-based approaches to security, and develop simulation-based and mathematical optimization methods for analyzing such models that exploit the high-performance computing capabilities at Sandia. Our first model studies security in interdependent settings, offering a scalable local search heuristic to approximate optimal security decisions in general, and a linear programming approach, coupled with simulations of consequences, to optimally compute security in an important special case. Our second class of models addresses security patrolling problems when an adversary gets to observe the patrol location. We present a general framework, based on stochastic games, for computing optimal security policies in such settings, and present more scalable tools that apply in the important special cases. Our third contribution is a model of security that involves many defenders, but only models non-adaptive attackers (or natural disasters, inadvertent errors, etc). In this model, we demonstrate that the security decisions of many players result in global security configuration that is not very far from optimal, and is much more resilient to environment changes that an optimal solution. This positive effect dissipates, however, when the number of decision makers becomes too large.

Vorobeychik, Yevgeniy↗

Hologic QDR 2000 whole-body scans: a comparison of three combinations of scan modes and analysis software

This study reports on the short-term in vivo precision and absolute measurements of three combinations of whole-body scan modes and analysis software using a Hologic QDR 2000 dual-energy X-ray densitometer. A group of 21 normal, healthy volunteers (11 male and 10 female) were scanned six times, receiving one pencil-beam and one array whole-body scan on three occasions approximately 1 week apart. The following combinations of scan modes and analysis software were used: pencil-beam scans analyzed with Hologic's standard whole-body software (PB scans); the same pencil-beam analyzed with Hologic's newer "enhanced" software (EPB scans); and array scans analyzed with the enhanced software (EA scans). Precision values (% coefficient of variation, %CV) were calculated for whole-body and regional bone mineral content (BMC), bone mineral density (BMD), fat mass, lean mass, %fat and total mass. In general, there was no significant difference among the three scan types with respect to short-term precision of BMD and only slight differences in the precision of BMC. Precision of BMC and BMD for all three scan types was excellent: < 1% CV for whole-body values, with most regional values in the 1%-2% range. Pencil-beam scans demonstrated significantly better soft tissue precision than did array scans. Precision errors for whole-body lean mass were: 0.9% (PB), 1.1% (EPB) and 1.9% (EA). Precision errors for whole-body fat mass were: 1.7% (PB), 2.4% (EPB) and 5.6% (EA). EPB precision errors were slightly higher than PB precision errors for lean, fat and %fat measurements of all regions except the head, although these differences were significant only for the fat and % fat of the arms and legs. In addition EPB precision values exhibited greater individual variability than PB precision values. Finally, absolute values of bone and soft tissue were compared among the three combinations of scan and analysis modes. BMC, BMD, fat mass, %fat and lean mass were significantly different between PB scans and either of the EPB or EA scans. Differences were as large as 20%-25% for certain regional fat and BMD measurements. Additional work may be needed to examine the relative accuracy of the scan mode/software combinations and to identify reasons for the differences in soft tissue precision with the array whole-body scan mode.

NASA Discipline Musculoskeletal↗

Development of the Resource Prospector Planetary Rover

The Resource Prospector (RP) is an In-­‐Situ Resource Utilization (ISRU) lunar rover mission under study by NASA. RP is planned to launch in 2020 to prospect for subsurface volatiles and to extract oxygen from lunar regolith. The mission will address several of NASA's "Strategic Knowledge Gaps" for lunar exploration. The mission will also address the Global Exploration Roadmap's strategic goal of using local resources for human exploration. The distribution of lunar subsurface volatiles drives the mission requirement for mobility. The spatial distribution is hypothesized to be governed by impact cratering with the top 0.5 m being patchy at scales of 100 m. The mixing time scale increases with depth (less frequent larger impacts). Consequently, increased mobility reduces the depth requirement for sampling. The target RP traverse will extend 1 km radially from the landing site to sample craters of varying sizes. Sampling craters with different ages will reveal possible volatile emplacement history. In 1 Ga, approximately 60-­70 craters of 10 m diameter form per km2. Thus, the rover will need to sample at least ten of these craters, which may require a total traverse path length of 2-­‐3 km. During 2014-­2015, we developed an initial prototype rover for RP. The current design is a solar powered, four-­wheeled vehicle, with hub motor drive, offset four wheel steering, and active suspension. Active suspension provides capabilities including changing vehicle ride height, traversing comparatively large obstacles, and controlling load on the wheels. All-­wheel steering enables the vehicle to point arbitrarily while roving, e.g., to keep the solar array pointed at the sun while in motion. The offset steering combined with active suspension improves driving in soft soil. The rover's on-­board software utilizes NASA's Core Flight Software, which is a reusable flight software environment. During 2015, we completed the initial rover software build, which provides low-­level hardware interfaces, basic mobility control, waypoint driving, odometry, basic error checking, and camera services. Development of the prototype rover has enabled maturation of many of the subsystems to TRL 5. During the next year, we will conduct integrated testing of concepts of operation, navigation, and remote driving tools. In addition, we will perform environmental tests including radiation (avionics), thermal and thermal/vacuum (mechanisms), and gravity offload (mobility).

robotics↗

Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass

OBJECTIVE: To determine whether near infrared spectroscopic measurement of tissue pH and Po2 has sufficient accuracy to assess variation in tissue perfusion resulting from changes in blood pressure and metabolic demand during cardiopulmonary bypass. DESIGN: Prospective clinical study. SETTING: Academic medical center. SUBJECTS: Eighteen elective cardiac surgical patients. INTERVENTION: Cardiac surgery under cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: A near infrared spectroscopic fiber optic probe was placed over the hypothenar eminence. Reference Po2 and pH sensors were inserted in the abductor digiti minimi (V). Data were collected every 30 secs during surgery and for 6 hrs following cardiopulmonary bypass. Calibration equations developed from one third of the data were used with the remaining data to investigate sensitivity of the near infrared spectroscopic measurement to physiologic changes resulting from cardiopulmonary bypass. Near infrared spectroscopic and reference pH and Po2 measurements were compared for each subject using standard error of prediction. Near infrared spectroscopic pH and Po2 at baseline were compared with values during cardiopulmonary bypass just before rewarming commenced (hypotensive, hypothermic), after rewarming (hypotensive, normothermic) just before discontinuation of cardiopulmonary bypass, and at 6 hrs following cardiopulmonary bypass (normotensive, normothermic) using mixed-model analysis of variance. Near infrared spectroscopic pH and Po2 were well correlated with the invasive measurement of pH (R2 =.84) and Po2 (R 2 =.66) with an average standard error of prediction of 0.022 +/- 0.008 pH units and 6 +/- 3 mm Hg, respectively. The average difference between the invasive and near infrared spectroscopic measurement was near zero for both the pH and Po2 measurements. Near infrared spectroscopic Po2 significantly decreased 50% on initiation of cardiopulmonary bypass and remained depressed throughout the bypass and monitored intensive care period. Near infrared spectroscopic pH decreased significantly during cardiopulmonary bypass, decreased significantly during rewarming, and remained depressed 6 hrs after cardiopulmonary bypass. Diabetic patients responded differently than nondiabetic subjects to cardiopulmonary bypass, with lower muscle pH values (p =.02). CONCLUSIONS: Near infrared spectroscopic-measured muscle pH and Po2 are sensitive to changes in tissue perfusion during cardiopulmonary bypass.

Non-NASA Center↗

Radiation-induced genomic instability

Quantitative assessment of the heritable somatic effects of ionizing radiation exposures has relied upon the assumption that radiation-induced lesions were 'fixed' in the DNA prior to the first postirradiation mitosis. Lesion conversion was thought to occur during the initial round of DNA replication or as a consequence of error-prone enzymatic processing of lesions. The standard experimental protocols for the assessment of a variety of radiation-induced endpoints (cell death, specific locus mutations, neoplastic transformation and chromosome aberrations) evaluate these various endpoints at a single snapshot in time. In contrast with the aforementioned approaches, some studies have specifically assessed radiation effects as a function of time following exposure. Evidence has accumulated in support of the hypothesis that radiation exposure induces a persistent destabilization of the genome. This instability has been observed as a delayed expression of lethal mutations, as an enhanced rate of accumulation of non-lethal heritable alterations, and as a progressive intraclonal chromosomal heterogeneity. The genetic controls and biochemical mechanisms underlying radiation-induced genomic instability have not yet been delineated. The aim is to integrate the accumulated evidence that suggests that radiation exposure has a persistent effect on the stability of the mammalian genome.

NASA Discipline Radiation Health↗

Using EMG to anticipate head motion for virtual-environment applications

In virtual environment (VE) applications, where virtual objects are presented in a see-through head-mounted display, virtual images must be continuously stabilized in space in response to user's head motion. Time delays in head-motion compensation cause virtual objects to "swim" around instead of being stable in space which results in misalignment errors when overlaying virtual and real objects. Visual update delays are a critical technical obstacle for implementing head-mounted displays in applications such as battlefield simulation/training, telerobotics, and telemedicine. Head motion is currently measurable by a head-mounted 6-degrees-of-freedom inertial measurement unit. However, even given this information, overall VE-system latencies cannot be reduced under about 25 ms. We present a novel approach to eliminating latencies, which is premised on the fact that myoelectric signals from a muscle precede its exertion of force, thereby limb or head acceleration. We thus suggest utilizing neck-muscles' myoelectric signals to anticipate head motion. We trained a neural network to map such signals onto equivalent time-advanced inertial outputs. The resulting network can achieve time advances of up to 70 ms.

Clinical Trial↗

Composting on Mars or the Moon: I. Comparative evaluation of process design alternatives

As a candidate technology for treating solid wastes and recovering resources in bioregenerative Advanced Life Support, composting potentially offers such advantages as compactness, low mass, near ambient reactor temperatures and pressures, reliability, flexibility, simplicity, and forgiveness of operational error or neglect. Importantly, the interactions among the physical, chemical, and biological factors that govern composting system behavior are well understood. This article comparatively evaluates five Generic Systems that describe the basic alternatives to composting facility design and control. These are: 1) passive aeration; 2) passive aeration abetted by mechanical agitation; 3) forced aeration--O2 feedback control; 4) forced aeration--temperature feedback control; 5) forced aeration--integrated O2 and temperature feedback control. Each of the five has a distinctive pattern of behavior and process performance characteristics. Only Systems 4 and 5 are judged to be viable candidates for ALS on alien worlds, though which is better suited in this application is yet to be determined.

Review↗

Lessons Learned from the Clementine Mission

According to BMDO, the Clementine mission achieved many of its technology objectives during its flight to the Moon in early 1994 but, because of a software error, was unable to test the autonomous tracking of a cold target. The preliminary analyses of the returned lunar data suggest that valuable scientific measurements were made on several important topics but that COMPLEX's highest-priority objectives for lunar science were not achieved. This is not surprising given that the rationale for Clementine was technological rather than scientific. COMPLEX lists below a few of the lessons that may be learned from Clementine. Although the Clementine mission was not conceived as a NASA science mission exactly like those planned for the Discovery program, many operational aspects of the two are similar. It is therefore worthwhile to understand the strengths and faults of the Clementine approach. Some elements of the Clementine operation that led to the mission's success include the following: (1) The mission's achievements were the responsibility of a single organization and its manager, which made that organization and that individual accountable for the final outcome; (2) The sponsor adopted a hands-off approach and set a minimum number of reviews (three); (3) The sponsor accepted a reasonable amount of risk and allowed the project team to make the trade-offs necessary to minimize the mission's risks while still accomplishing all its primary objectives; and (4) The development schedule was brief and the agreed-on funding (and funding profile) was adhered to. Among the operational shortcomings of Clementine were the following: (1) An overly ambitious schedule and a slightly lean budget (meaning insufficient time for software development and testing, and leading ultimately to human exhaustion); and (2) No support for data calibration, reduction, and analysis. The principal lesson to be learned in this category is that any benefits from the constructive application of higher risk for lower cost and faster schedule will be lost if the schedule does not allow adequate time for the development of all essential systems or makes no allowance for human frailties. Another lesson to be drawn is that despite its limitations, if judged strictly as a science mission, Clementine attested that significant scientific information can be gathered during a technology-demonstration mission. In the current era of limited funds, when science missions will be infrequent, the opportunity to fly scientific instruments aboard missions whose objectives might be other than science must be seized and, indeed, encouraged. During such opportunities it would be inexcusable to do second-class science. Thus the scientific community must be actively involved in such projects from their initiation.

Source record↗

Non-exercise Estimation of V02max Using a Dichotomy of Meeting or Not Meeting DHHS Physical Activity Recommendations

The physical activity guidelines (PAG) established by the US Dept. of Health and Human Services in 2008 is consistent with a rating of >/= 6 on the 11-point NASA Physical Activity Status Scale (PASS). Wier, et. al. developed non-exercise models for estimating VO2(sub max) from a combination of PASS, age, gender and either waist girth (WG) (R = 0.810, SEE= 4.799 ml/kg/min), %Fat (R = 0. 817, SEE = 4.716 ml/kg/min) or BMI (R = 0.802, SEE = 4.900 ml . kg-1. min -1 ). PURPOSE: to develop non-exercise models to estimate VO2max from age, gender, body composition (WG, %Fat, BMI) and PASS dichotomized at meets or does not meet the PAG (PAG-PASS), and to compare the accuracy of the PAG-PASS models with the models using the 11-point PASS. METHODS: 2417 men and 384 women were measured for VO2max by indirect calorimetry (RER >1.1); age (yr), gender by M = 1, W = 0; WG at the umbilicus; %fat by skin-folds, BMI by weight (kg) divided by height squared (m 2 ) , and PAGPASS by PASS < 6 = 0 and =/> 6 = 1. RESULTS: Three models were developed by multiple regression to estimate VO2(sub max) from age, gender, PAG-PASS and either WG (R = 0.790, SEE=5.019 ml/kg/min), %FAT (R= 0.080, SEE = 4.915 ml/kg/min) or BMI (R = 0.777, SEE = 5.162ml/kg/min). Cross-validation by the PRESS technique confirmed these statistics. Simple correlations between measured VO2(sub max) and estimates from the PAG-PASS models with WG, %Fat and BMI were 0.790, 0.800 and 0.777, minimally different from the correlations obtained with the PASS models (0.810, 0.810, and 0.802). PAG-PASS and PASS model constant errors were also similar: < 1 ml/kg/min for subsamples of age, gender, PASS and for VO2(sub max) between 30 and 50 ml/kg/min (70% of the sample) but > 1 ml/kg/min for VO2(sub max) <30 and >50 ml/kg/min. CONCLUSIONS: Non-exercise models using the combined effects of age, gender, body composition and the dichotomized PAG-PASS provide estimates of VO2(sub max) that are accurate for most adults, and the accuracy of these models are similar to previously published models using the 11-point PASS.

Wier, Larry T.↗