Dependence of magnetomechanical performance of CoGaxFe2-xO4 on temperature variation

The temperature dependence of the magnetoelastic properties of the CoGa{sub x}Fe{sub 2-x}O{sub 4} system (for x = 0.0, 0.2, and 0.4) has been studied. It has been shown that increase in temperature resulted in reduced magnetostrictive hysteresis. For both CoGa{sub 0.2}Fe{sub 1.8}O{sub 4} and CoGa{sub 0.4}Fe{sub 1.6}O{sub 4}, the measured magnetostriction amplitudes were higher at 250 K than at 150 K. It was also shown that the temperature stability of magnetostriction in CoGa{sub 0.2}Fe{sub 1.8}O{sub 4} is higher than that of the other compositions studied which is important for sensor applications. The highest strain sensitivity was obtained for CoGa{sub 0.2}Fe{sub 1.8}O{sub 4} at 250 K. Results demonstrate the possibility of tailoring magnetomechanical properties of the material to suit intended applications under varying temperature conditions.

36 MATERIALS SCIENCE↗

Scanning Microscopes Using X Rays and Microchannels

Scanning microscopes that would be based on microchannel filters and advanced electronic image sensors and that utilize x-ray illumination have been proposed. Because the finest resolution attainable in a microscope is determined by the wavelength of the illumination, the xray illumination in the proposed microscopes would make it possible, in principle, to achieve resolutions of the order of nanometers about a thousand times as fine as the resolution of a visible-light microscope. Heretofore, it has been necessary to use scanning electron microscopes to obtain such fine resolution. In comparison with scanning electron microscopes, the proposed microscopes would likely be smaller, less massive, and less expensive. Moreover, unlike in scanning electron microscopes, it would not be necessary to place specimens under vacuum. The proposed microscopes are closely related to the ones described in several prior NASA Tech Briefs articles; namely, Miniature Microscope Without Lenses (NPO-20218), NASA Tech Briefs, Vol. 22, No. 8 (August 1998), page 43; and Reflective Variants of Miniature Microscope Without Lenses (NPO-20610), NASA Tech Briefs, Vol. 26, No. 9 (September 2002) page 6a. In all of these microscopes, the basic principle of design and operation is the same: The focusing optics of a conventional visible-light microscope are replaced by a combination of a microchannel filter and a charge-coupled-device (CCD) image detector. A microchannel plate containing parallel, microscopic-cross-section holes much longer than they are wide is placed between a specimen and an image sensor, which is typically the CCD. The microchannel plate must be made of a material that absorbs the illuminating radiation reflected or scattered from the specimen. The microchannels must be positioned and dimensioned so that each one is registered with a pixel on the image sensor. Because most of the radiation incident on the microchannel walls becomes absorbed, the radiation that reaches the image sensor consists predominantly of radiation that was launched along the longitudinal direction of the microchannels. Therefore, most of the radiation arriving at each pixel on the sensor must have traveled along a straight line from a corresponding location on the specimen. Thus, there is a one-to-one mapping from a point on a specimen to a pixel in the image sensor, so that the output of the image sensor contains image information equivalent to that from a microscope.

Wang, Yu↗

Water linked 3D coordination polymers: Syntheses, structures and applications

Three new coordination polymers (CPs) based on Cd and Pb, [Cd(OBA)(μ-H{sub 2}O)(H{sub 2}O)]{sub n}1, [Pb(OBA)(μ-H{sub 2}O)]{sub n}2 [where OBA=4,4’-Oxybis(benzoate)] and [Pb(SDBA)(H{sub 2}O)]{sub n}.1/4DMF 3 (SDBA=4,4’-Sulfonyldibenzoate), have been synthesized and characterized. The single crystal structural studies reveal that CPs 1 and 2 have three dimensional structure. A water molecule bridges two metal centres which appears to the responsible for the dimensionality increase from 2D to 3D. Compound 3 has a supramolecular 3D structure involving water molecule and hydrogen bonds. A structural transformation is observed when 3 was heated at 100 °C or kept in methanol, forming [Pb(SDBA)]{sub n}4. Compound 4 is used as supporting matrix for palladium nanoparticles, PdNPs@4. The PdNPs@4 exhibits good catalytic activity toward the reduction of 4-nitrophenol (4-NP) to 4-aminophenol (4-AP) in the presence of NaBH{sub 4} at room temperature. Luminescence studies revealed that all CPs could be an effective sensor for nitroaromatic explosives. - Graphical abstract: Three new CPs based on Cd and Pb, have been synthesized and characterized. A water molecule bridges two metal centres which appears to the responsible for the dimensionality increase from 2D to 3D. One of the CP is used as supporting matrix for palladium nanoparticles, PdNPs@4. The PdNPs@4 exhibits good catalytic activity toward the reduction of 4-nitrophenol. Luminescence studies shown that all CPs could be an effective sensor for nitroaromatic explosives. - Highlights: • Three new CPs based on Cd and Pb, have been synthesized and characterized. • A water molecule bridges two metal centres which appears to the responsible for the dimensionality increase from 2D to 3D. • One of the CP is used as supporting matrix for palladium nanoparticles, PdNPs@4. • Luminescence studies shown that all CPs could be an effective sensor for nitroaromatic explosives.

36 MATERIALS SCIENCE↗

Fiber Optic Sensor for Corrosion Monitoring in Molten Salt Irradiation Experiments

Molten salt reactors (MSRs) are one of the more promising advanced reactor concepts because they offer passive safety, high-temperature process heat, and the potential for improved fuel cycle economics through online reprocessing [1]. However, before MSRs can be reliably deployed, structural materials must be identified that can survive extended exposure to highly-corrosive salts during irradiation at high temperatures. The U.S. Department of Energy (DOE) is funding the design and eventual construction of a Versatile Test Reactor (VTR) that will include experimental facilities for testing under conditions representative of several advanced reactors, including MSRs [2]. These facilities will allow testing of candidate structural materials during irradiation with flowing salt. If properly designed, these experiments will allow for post-irradiation characterization of weight loss in the structural material coupons. However, significantly more information could be gained if the corrosion could be monitored in situ.There are currently no commercially available sensors for in situ corrosion monitoring at temperatures in the range of 500–900°C [3]. An in situ corrosion sensor would also have to survive high-dose neutron irradiation and extended exposure chemically aggressive media (e.g., molten salts). While there are ongoing efforts to use the change in magnetic susceptibility of Cr-containing alloys, this technique is limited to Cr-containing structural materials and there are concerns when using a magnetic susceptibility sensor at temperatures approaching the Curie temperature of iron (770°C) [4].

Petrie, Christian M.↗

Summary of the Active Microwave Workshop, chapter 1

An overview is given of the utility, feasibility, and advantages of active microwave sensors for a broad range of applications, including aerospace. In many instances, the material provides an in-depth examination of the applicability and/or the technology of microwave remote sensing, and considerable documentation is presented in support of these techniques. An assessment of the relative strengths and weaknesses of active microwave sensor data indicates that satisfactory data are obtainable for several significant applications.

Source record↗

Compact Multi-Gas Monitor for Life Support Systems Control in Space: Evaluation Under Realistic Environmental Conditions

Advanced space life support systems require lightweight, low-power, durable sensors for monitoring critical gas components. A luminescence-based optical flow-through cell to monitor carbon dioxide, oxygen, and humidity has been developed and was demonstrated using bench-top instrumentation under environmental conditions relevant to portable life support systems, including initially pure oxygen atmosphere, temperature range from 50 F to 150 F, and humidity from dry to 100% RH and under conditions of water condensation. This paper presents the most recent progress in the development of this sensor technology. Trace gas contaminants in a space suit, originating from hardware and material off-gassing and crew member metabolism, are from many chemical families. The result is a gas mix much more complex than the pure oxygen fed into the space suit, and this complexity may interfere with gas sensor readings. This paper presents an evaluation of optical sensor performance when exposed to the most significant trace gases reported to be found in space suits. A study of the calibration stability of the sensors is also presented. For that purpose, a profile of temperature, pressure, humidity, and gas composition for the duration of an EVA has been defined, and the performance of sensors operated repeatedly under those conditions has been studied. Finally, this paper presents the first compact readout unit for these optical sensors, designed for the volume, power, and weight restrictions of a PLSS.

Alonso, Jesus Delgado↗

Raman spectra of aligned carbon micro-coils and their impedance characteristics under loads

Scanning and transmission electron microscopy were used to characterize the morphology of the carbon microcoils (CMCs). The Raman spectra showed that CMCs had local regular structure as I{sub D}/I{sub G} = 0.841. Then, aligned CMCs/silicone–rubber composites (5 × 5 × 1 mm{sup 3}) were fabricated by coating of silicone rubber on the CMCs. Their alternating current impedance characteristics were measured as a function of applied load and the pressure sensitivity was discussed. The results showed that the impedance decreased as the increasing applied load, and the sample with less CMCs owned high pressure sensitivity, which indicated a novel composite film could act as an alternative of tactile sensor.

36 MATERIALS SCIENCE↗

Robust, self-assembled, biocompatible films

The present invention provides a composite material including a substrate having an oxide surface, and, a continuous monolayer on the oxide surface, the monolayer including a silicon atom from a trifunctional alkyl/alkenyl/alkynyl silane group that attaches to the oxide surface, an alkyl/alkenyl/alkynyl portion of at least three carbon atoms, a polyalkylene glycol spacer group, and either a reactive site (e.g., a recognition ligand) or a site resistant to non-specific binding (e.g., a methoxy or the like) at the terminus of each modified SAM. The present invention further provides a sensor element, a sensor array and a method of sensing, each employing the composite material. Patterning is also provided together with backfilling to minimize non-specific binding.

59 BASIC BIOLOGICAL SCIENCES↗

Improved Performance of Zinc Oxide Thin Film Transistor Pressure Sensors and a Demonstration of a Commercial Chip Compatibility with the New Force Sensing Technology

Abstract A zinc oxide thin film transistor is developed and optimized that simultaneously functions as a transistor and a force sensor, thus allowing for scalable integration of sensors into arrays without the need for additional addressing elements. Through systematic material deposition, microscopy, and piezoelectric characterization, it is determined that an O 2 rich deposition condition improves the transistor performance and pressure sensing characteristics. With these optimizations, a sensitivity of 4 nA kPa −1 and a latency of below 1 ms are achieved, exceeding the criteria for successful commercialization of arrayed pressure sensors. The functionality of 16 × 16 pressure sensor arrays on thin bendable glass substrates for integrated low weight and flexible touchscreen displays is fabricated and demonstrated and read‐out electronics to interface with the arrays and to record their response in real‐time are developed. Finally, the application of these sensors for mobile displays via their operation with an existing commercial touch integrated circuit controller is demonstrated.

Vishniakou, Siarhei↗

Synthesis of graphene-like carbon from biomass pyrolysis and its applications

Two-dimensional graphene materials attracted much attention worldwide because of their superior performance in electronic devices, sensors, and energy storage. However, its application is limited by high cost and insufficient production. The work to find out a simple and environmentally friendly process is highly needed. Designed pyrolysis of biomass precursors can derive graphene-like materials. This review summarizes some typical preparation processes for graphene-like materials synthesis from biomass carbonization via pyrolysis, including salt-based activation, template-based confinement, chemical blowing, coupling with hydrothermal carbonization pretreatment, post exfoliation, and some other methods. The operation of these methods and the performance of obtained graphene-like materials were closely highlighted. The scalability of the techniques and the applications of the biomass graphene-like carbon were also discussed. Some advanced characterization methods, such as SEM, TEM, AFM, Raman, and XPS to determine the graphene-like structure and graphitization degree were also discussed. In the end, some current challenges and future perspectives of the synthesis of these graphene-like materials were concluded.

pyrolysis, graphene, biomass, application, scalabi↗

Correlation between sensors' signals and internal resolution of a strip detector

In this work, the theory of branching cascade processes is applied to the description of signal formation in a strip detector for soft X-rays. The theory is applicable to detectors' absorbers that have a single type of intrinsic particles. Intrinsic particles are particles that are generated by incident particle in detector's absorber and cause signals at the strip detector sensors' electronics. From this theory, it follows the new method of experimental determination of the Fano factor. It is shown, that the relative covariance between two signals of a strip detector depends on the fundamental combination of the Fano factor and the effective energy of the intrinsic particle creation in the absorber material. The important advantage of proposed method is its independence from the sensors' electronic gains and noises. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Biomimetic actuators using electroactive polymers (EAP) as artificial muscles

Evolution has resolved many of nature's challenges leading to lasting solutions with maximal performance and effective use of resources. Nature's inventions have always inspired human achievements leading to effective materials, structures, tools, mechanisms, processes, algorithms, methods, systems and many other benefits. The field of mimicking nature is known as Biomimetics and one of its topics includes electroactive polymers that gain the moniker artificial muscles. Integrating EAP with embedded sensors, self-repair and many other capabilities that are used in composite materials can add greatly to the capability of smart biomimetic systems. Such development would enable fascinating possibilities potentially turning science fiction ideas into engineering reality.

Electroactive Polymers (EAP)↗

Printed Strain Gauges for High Temperature Applications (>300°C)

The real-time understanding of strain and deformation of materials provides prognostic health monitoring of components of current operational reactors and valuable data that shortens the timeline for the development of new nuclear-relevant materials in test reactor experiments. This report discusses the current development and testing of additively manufactured strain gauges. This has potential to improve the sensor design and manufacturing techniques to meet the requirements of the current and advanced nuclear reactors (i.e., in terms of environment conditions, sample geometry, and materials compatibility). The developmental additively manufactured strain gauges are exposed to separate effects testing (i.e., mechanical strain, high temperature) to determine environmental factors that affect the strain gauge. In addition, sensor qualification methodologies are further developed for determining the reliability and robustness at the interface of the AM strain gauge materials.

36 MATERIALS SCIENCE↗

Tuning Ultrafast Photoinduced Strain in Ferroelectric-Based Devices

Ferroelectric materials exhibit coupled degrees of freedom and possess a switchable electric polarization coupled to strain, making them good piezoelectrics and enabling numerous devices including nonvolatile memories, actuators, and sensors. Moreover, novel photovoltaic effects are encountered through the interplay of electric polarization with the material optical properties. Consequently, light-induced deformation in ferroelectrics, or photostriction, combining photovoltaic and converse piezoelectric effects, is under investigation in the quest for multifunctional materials. Using time-resolved X-ray diffraction, the first control of ultrafast photoinduced strain is demonstrated through in situ tuning of the polarization state in ferroelectric-based devices. Both the magnitude and the sign of the photoinduced strain strongly depend on the transient photoinduced change of the internal electric field in the ferroelectric layer, and can be actively engineered to achieve two distinct remanent photostrictive responses. These results provide fundamental insight into light–matter interaction in ferroelectrics and exciting new avenues for materials functionality engineering.

36 MATERIALS SCIENCE↗

Enhanced piezoelectric performance of (0.98-x)Bi(Sc{sub 3/4}In{sub 1/4})O{sub 3}-xPbTiO{sub 3}-0.02Pb(Zn{sub 1/3}Nb{sub 2/3})O{sub 3} ternary high temperature piezoelectric ceramics

(0.98-x)Bi(Sc{sub 3/4}In{sub 1/4})O{sub 3}-xPbTiO{sub 3}-0.02Pb(Zn{sub 1/3}Nb{sub 2/3})O{sub 3} (BSI-PT-PZN) high temperature piezoelectric ceramics were prepared by traditional solid-state reaction method. Combining X-ray diffraction results with piezoelectric data, it was found that the morphotropic phase boundary (MPB) occurred at x = 0.575. The piezoelectric constant d{sub 33}, curie temperature T{sub c}, and electromechanical coupling factor k{sub p} of BIS-PT-PZN ceramics with MPB composition were 427 pC/N, 412 Degree-Sign C, and 0.51, respectively. Furthermore, the strain of BIS-PT-PZN ceramics reached up to 0.25% under the electric field of 40 kV/cm. Temperature-dependent electromechanical coupling coefficient for MPB composition was stable from room temperature up to 350 Degree-Sign C. The piezoelectric properties of BIS-PT-PZN ceramics were comparable to that of 0.36BiScO{sub 3}-0.64PbTiO{sub 3} (BS-PT) ceramics, and the piezoelectric constant d{sub 33} of BIS-PT-PZN ceramics was about twice that of our previous reported 0.4Bi(Sc{sub 3/4}In{sub 1/4})O{sub 3}-0.6PbTiO{sub 3} (BSI-PT) ceramics. The reduction in the expensive Sc{sub 2}O{sub 3} content and comparable piezoelectric properties with BS-PT ceramics indicated that BIS-PT-PZN ceramics were promising for commercial applications as high temperature actuators and sensors.

36 MATERIALS SCIENCE↗

OAST Space Theme Workshop. Volume 3: Working group summary. 7: Material (M-1). A. Statement. B. Technology needs (form 1). C. Priority assessment (form 2)

The approach of matching technology areas with various themes needs was not effective for the materials and thermal control discipline because of the diversity of requirements for each. Top priorities were evolved from the advanced space transportation system and the space power platform because these are essential building blocks in fulfilling some of the other themes. Important needs identified include life long-life cryogenic cooling systems for sensors, masers, and other devices and the needs for lightweight nuclear shielding materials for nuclear electric propulsion.

Source record↗

Solid State Carbon Monoxide Sensor

A means for detecting carbon monoxide which utilizes an un-heated catalytic material to oxidize carbon monoxide at ambient temperatures. Because this reaction is exothermic, a thermistor in contact with the catalytic material is used as a sensing element to detect the heat evolved as carbon monoxide is oxidized to carbon dioxide at the catalyst surface, without any heaters or external heating elements for the ambient air or catalytic element material. Upon comparison to a reference thermistor, relative increases in the temperature of the sensing thermistor correspond positively with an increased concentration of carbon monoxide in the ambient medium and are thus used as an indicator of the presence of carbon monoxide.

Upchurch, Billy T.↗

Adjustment of Sensor Locations During Thermal Property Parameter Estimation

The temperature dependent thermal properties of a material may be evaluated from transient temperature histories using nonlinear parameter estimation techniques. The usual approach is to minimize the sum of the squared errors between measured and calculated temperatures at specific locations in the body. Temperature measurements are usually made with thermocouples and it is customary to take thermocouple locations as known and fixed during parameter estimation computations. In fact, thermocouple locations are never known exactly. Location errors on the order of the thermocouple wire diameter are intrinsic to most common instrumentation procedures (e.g., inserting a thermocouple into a drilled hole) and additional errors can be expected for delicate materials, difficult installations, large thermocouple beads, etc.. Thermocouple location errors are especially significant when estimating thermal properties of low diffusively materials which can sustain large temperature gradients during testing. In the present work, a parameter estimation formulation is presented which allows for the direct inclusion of thermocouple positions into the primary parameter estimation procedure. It is straightforward to set bounds on thermocouple locations which exclude non-physical locations and are consistent with installation tolerances. Furthermore, bounds may be tightened to an extent consistent with any independent verification of thermocouple location, such as x-raying, and so the procedure is entirely consonant with experimental information. A mathematical outline of the procedure is given and its implementation is illustrated through numerical examples characteristic of light-weight, high-temperature ceramic insulation during transient heating. The efficacy and the errors associated with the procedure are discussed.

Milos, Frank S.↗