Search NASA⌕ Search

SEARCH · Search NASA

Results for “method of cells”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Characterization of Thermophotovoltaic Cells

Thermophotovoltaic (TPV) research has entered a period of rapid expansion after 30 years of effort, yet there is still no comprehensive method of TPV cell characterization. Simple procedures allow the derivation of temperature coefficients for Voc and Isc as well as the intensity coeffcient for Voc.

temperature thermophotovoltaic cells (TPV)↗

Layout optimization with algebraic multigrid methods

Finding the optimal position for the individual cells (also called functional modules) on the chip surface is an important and difficult step in the design of integrated circuits. This paper deals with the problem of relative placement, that is the minimization of a quadratic functional with a large, sparse, positive definite system matrix. The basic optimization problem must be augmented by constraints to inhibit solutions where cells overlap. Besides classical iterative methods, based on conjugate gradients (CG), we show that algebraic multigrid methods (AMG) provide an interesting alternative. For moderately sized examples with about 10000 cells, AMG is already competitive with CG and is expected to be superior for larger problems. Besides the classical 'multiplicative' AMG algorithm where the levels are visited sequentially, we propose an 'additive' variant of AMG where levels may be treated in parallel and that is suitable as a preconditioner in the CG algorithm.

Regler, Hans↗

Utilizing fluorescent life time imaging microscopy technology for identify carriers of BRCA2 mutation

Worldwide, more than one million women are diagnosed with breast cancer every year, making it the most common female malignancy in the developed world. Germline mutations in BRCA1 and BRCA2 genes are estimated to increase the risk for developing breast cancer by up to 87%. From a clinical point of view, identification of BRCA1 and BRCA2 mutation carriers offers an opportunity to early identify or prevent the development of malignancy; therefore the ability to determine which women are more likely to carry BRCA1 or BRCA2 mutations is of great importance. The available diagnostic tests for mutation analysis of BRCA1 and BRCA2 are time- and labor-intensive, expensive, and do not allow the identification of all the functional mutations. We utilized the Fluorescent lifetime (FLT) imaging microscopy method which allows recognizing different cell populations, in order to distinguish between lymphocytes from BRCA1 and BRCA2 mutation carriers and non-carrier women by using easily obtainable lymphocyte cells from peripheral blood. Our results demonstrate that cells originated from BRCA2-mutation carriers have significantly lower FLT values compared with BRCA1 mutation carriers and control cells. This simple, inexpensive and sensitive method may be utilized in the future to detect BRCA2 mutation carriers, particularly those bearing unknown functional mutations. - Highlights: • Fluorescent lifetime imaging microscopy (FLIM) technology can be used for recognizing BRCA mutation carriers. • Cells originated from BRCA2-mutation carriers have lower FLT values compared with BRCA1 mutation carriers and control cells. • The difference in FLT values were observed regardless irradiation. • FLIM method may be more informative in the detection of BRCA2-mutation carriers than BRCA1.

60 APPLIED LIFE SCIENCES↗

Parallel macromolecular delivery and biochemical/electrochemical interface to cells employing nanostructures

Systems and methods are described for parallel macromolecular delivery and biochemical/electrochemical interface to whole cells employing carbon nanostructures including nanofibers and nanotubes. A method includes providing a first material on at least a first portion of a first surface of a first tip of a first elongated carbon nanostructure; providing a second material on at least a second portion of a second surface of a second tip of a second elongated carbon nanostructure, the second elongated carbon nanostructure coupled to, and substantially parallel to, the first elongated carbon nanostructure; and penetrating a boundary of a biological sample with at least one member selected from the group consisting of the first tip and the second tip.

59 BASIC BIOLOGICAL SCIENCES↗

Preservation of rat hearts in subfreezing temperature isochoric conditions to – 8 °C and 78 MPa

Highlights: • A novel method of low-temperature organ preservation is tested using rat hearts. • Isochoric systems allow ice-free preservation at temperatures well below freezing. • Conventional heart preservation employs on-ice storage in atmospheric conditions. • Histological quality is improved in hearts preserved in a −4 °C isochoric system. Isochoric (constant volume) preservation at subfreezing temperatures is being investigated as a novel method for preserving cells and organs. This study is a first initial effort to evaluate the efficacy of this method for heart preservation, and to provide a preliminary outline of appropriate preservation parameters. To establish a baseline for further studies, rat hearts were preserved in a University of Wisconsin (UW) intracellular solution for one hour under isochoric conditions at: 0 °C (atmospheric pressure - 0.1 MPa), - 4 °C (41 MPa), - 6 °C (60 MPa) and – 8 °C (78 MPa). The viability of the heart was evaluated using Langendorff perfusion and histological examination. The physiological performance of hearts preserved at – 4 °C (41 MPa) was comparable to that of a heart preserved on ice at atmospheric pressure, with no statistically significant difference in histological injury score. However, hearts preserved at −4 °C displayed substantially reduced interstitial edema compared to hearts preserved by conventional hypothermic preservation in UW on ice at atmospheric pressure, suggesting significant protection from increased vascular permeability following preservation. Hearts preserved at – 6 °C (60 MPa) suffered injury from cellular swelling and extensive edema, and at – 8 °C (78 MPa) hearts experienced significant morphological disruption. To the best of our knowledge, this is the first publication showing that a mammalian organ can survive low subfreezing temperatures without the use of a cryoprotective additive. Lowering the preservation temperature reduces metabolism and improves preservation quality, and these results suggest that improvements in preservation are possible at subzero temperatures with low to moderate pressures observed at −4 °C. Notably, tissue damage was observed at lower temperatures (−6 °C or below) accompanying further elevation of pressure associated with isochoric preservation that may prove detrimental. Therefore, subfreezing temperature isochoric preservation protocols should optimize, a combination of temperature and pressure that will minimize the negative effects of elevated pressure while retaining the beneficial effect of lower temperatures and reduced metabolism.

60 APPLIED LIFE SCIENCES↗

SU-E-T-146: Effects of Uncertainties of Radiation Sensitivity of Biological Modelling for Treatment Planning

Purpose: The aim of this study was to evaluate the distribution of uncertainty of cell survival by radiation, and assesses the usefulness of stochastic biological model applying for gaussian distribution. Methods: For single cell experiments, exponentially growing cells were harvested from the standard cell culture dishes by trypsinization, and suspended in test tubes containing 1 ml of MEM(2x10{sup 6} cells/ml). The hypoxic cultures were treated with 95% N{sub 2}−5% CO{sub 2} gas for 30 minutes. In vitro radiosensitization was also measured in EMT6/KU single cells to add radiosensitizer under hypoxic conditions. X-ray irradiation was carried out by using an Xray unit (Hitachi X-ray unit, model MBR-1505R3) with 0.5 mm Al/1.0 mm Cu filter, 150 kV, 4 Gy/min). In vitro assay, cells on the dish were irradiated with 1 Gy to 24 Gy, respectively. After irradiation, colony formation assays were performed. Variations of biological parameters were investigated at standard cell culture(n=16), hypoxic cell culture(n=45) and hypoxic cell culture(n=21) with radiosensitizers, respectively. The data were obtained by separate schedule to take account for the variation of radiation sensitivity of cell cycle. Results: At standard cell culture, hypoxic cell culture and hypoxic cell culture with radiosensitizers, median and standard deviation of alpha/beta ratio were 37.1±73.4 Gy, 9.8±23.7 Gy, 20.7±21.9 Gy, respectively. Average and standard deviation of D{sub 50} were 2.5±2.5 Gy, 6.1±2.2 Gy, 3.6±1.3 Gy, respectively. Conclusion: In this study, we have challenged to apply these uncertainties of parameters for the biological model. The variation of alpha values, beta values, D{sub 50} as well as cell culture might have highly affected by probability of cell death. Further research is in progress for precise prediction of the cell death as well as tumor control probability for treatment planning.

60 APPLIED LIFE SCIENCES↗

Cubit for MCNP Unstructured Mesh Analysis of Oktavian Benchmarks

The Monte Carlo N-Particle (MCNP) transport code developed by Los Alamos National Laboratory (LANL) can be used to transport various particles across user defined three dimensional (3D) geometries. Traditionally, these geometries are created as constructive solid geometry (CSG), involving the use of Boolean operators on defined surfaces to create 3D regions known as cells. A newer method of geometry definition in the MCNP code is unstructured mesh (UM) embedded within a CSG cell using the universe and fill repeated-structure features. An MCNP UM calculation requires an MCNP input file and mesh geometry file. The MCNP code cannot be used to generate UM geometry models. A computer-aided design (CAD) software is typically used to construct a solid geometry model, and a CAD file is then imported into a mesh generation software to prepare and generate a mesh model. Some mesh generation software packages have the ability to create a solid geometry and thus a separate CAD software for creating a CAD model is not needed. In this work, Cubit, a geometry creation and meshing software developed by Sandia National Laboratories, is used to construct UM models for MCNP simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experiments with suspended cells on the Space Shuttle

Spaceflight experiments since 1981 have demonstrated that certain cell functions are altered by micro-g. Biophysical models suggest that cell membranes and organelles should not be affected directly by gravity, however, the chemical microenvironment surrounding the cell and molecular transport could be altered by reduced gravity. Most experiments have used suspended live cells in small chambers without stirring or medium exchange. Flight results include increased attachment of anchorage-dependent human cells to collagen coated microcarriers, reduced secretion of growth hormone from pituitary cells, decreased mitogenic response of lymphocytes, increased Interferon-alpha by lymphocytes, increased Interleukin-1 and Tumor Necrosis Factor secretion by macrophages. Related experiments on cells immediately postflight and on procaryotic cells have shown significant changes in secretory capacity, cell proliferation, differentiation and development. Postulated mechanism include altered cell-cell interactions, altered calcium ion transport, effects on cell cytoskeleton, transport of transmitters and interactions with receptors. The discussion includes use of new molecular methods, considerations for cell environmental control and a preview of several experiments planned for the Shuttle and Spacelab flights to study the basic effects of microgravity on cellular physiology and potential interactions of spaceflight with radiation damage and cellular repair mechanisms.

Review↗

Measurement of laser heating in spin exchange optical pumping by NMR diffusion sensitization gradients

This paper details pulsed gradient NMR measurements of the {sup 3}He diffusion coefficient in sealed cells during spin exchange optical pumping. The potential of ultra low field magnetic resonance imgaing (MRI) and NMR for noninvasive measurement of cell pressure is demonstrated. Diffusion sensitization gradients allow measurement of the {sup 3}He diffusion coefficient from which the pressure and/or temperature of the gas can be determined during optical pumping. The pressure measurements were compared with neutron time of flight transmission measurements. Good agreement was observed between the temperature/pressure measurements and predictions based on Chapman-Enskog theory. The technique had sufficient sensitivity to observe the diffusion coefficient increasing with temperature in a sealed cell. With this method, evidence for laser heating of the {sup 3}He during optical pumping was found. The results show that NMR diffusion measurements allow noninvasive measurement of the cell temperature and/or pressure in an optical pumping setup. The method can be expanded using MRI to probe the spatial distribution of the diffusion coefficient. These techniques can be applied to the further investigation of polarization limiting effects such as laser heating.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Method For Silicon Surface Texturing Using Ion Implantation

As the semiconductor industry continues to show more interest in the photovoltaic market, cheaper and readily integrable methods of silicon solar cell production are desired. One of these methods - ion implantation - is well-developed and optimized in all commercial semiconductor fabrication facilities. Here we have developed a silicon surface texturing technique predicated upon the phenomenon of surface blistering of H-implanted silicon, using only ion implantation and thermal annealing. We find that following the H implant with a second, heavier implant markedly enhances the surface blistering, causing large trenches that act as a surface texturing of c-Si. We have found that this method reduces total broadband Si reflectance from 35% to below 5percent;. In addition, we have used Rutherford backscattering/channeling measurements investigate the effect of ion implantation on the crystallinity of the sample. The data suggests that implantation-induced lattice damage is recovered upon annealing, reproducing the original monocrystalline structure in the previously amorphized region, while at the same time retaining the textured surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Preoperative Chemotherapy Versus Preoperative Chemoradiotherapy for Stage III (N2) Non-Small-Cell Lung Cancer

Purpose: To compare preoperative chemotherapy (ChT) and preoperative chemoradiotherapy (ChT-RT) in operable Stage III non-small-cell lung cancer. Methods and Materials: This retrospective study analyzed all patients with pathologically confirmed Stage III (N2) non-small-cell lung cancer who initiated preoperative ChT or ChT-RT at Duke University between 1995 and 2006. Mediastinal pathologic complete response (pCR) rates were compared using a chi-square test. The actuarial overall survival, disease-free survival, and local control were estimated using the Kaplan-Meier method and compared using the log-rank test. Multivariate Cox regression analysis was also performed. Results: A total of 101 patients who initiated preoperative therapy with planned resection were identified. The median follow-up was 20 months for all patients and 38 months for survivors. The mediastinal lymph nodes were reassessed after preoperative therapy in 88 patients (87%). Within this group, a mediastinal pCR was achieved in 35% after preoperative ChT vs. 65% after preoperative ChT-RT (p = 0.01). Resection was performed in 69% after ChT and 84% after ChT-RT (p = 0.1). For all patients, the overall survival, disease-free survival, and local control rate at 3 years was 40%, 27%, and 66%, respectively. No statistically significant differences were found in the clinical endpoints between the ChT and ChT-RT subgroups. On multivariate analysis, a mediastinal pCR was associated with improved disease-free survival (p = 0.03) and local control (p = 0.03), but not overall survival (p = 0.86). Conclusion: Preoperative ChT-RT was associated with higher mediastinal pCR rates but not improved survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exceeding 200 ns Lifetimes in Polycrystalline CdTe Solar Cells

CdTe photovoltaics has achieved one of the lowest levelized costs of electricity among all energy sources. However, for decades, carrier lifetimes have been inferior to those of other prevalent solar cell materials. This quality has inhibited common methods to improve solar cell efficiency such as back-surface fields, electron reflectors, or bifacial solar cells. In this work, a significant increase in carrier lifetime to values exceeding 200 ns in fully functional CdTe solar cells is demonstrated. The increased lifetime is achieved by large CdSeTe grains at the absorber/emitter interface, intragrain passivation in the absorber layer, and chemical passivation by forming nanoscale oxidized tellurium species at the transparent conducting oxide interface. The carrier lifetime is correlated to the open-circuit voltage and enables paths for back-surface manipulation and novel cell architectures to further improve CdTe photovoltaic performance.

14 SOLAR ENERGY↗

In Vitro Cytotoxicity of Low-Dose-Rate Radioimmunotherapy by the Alpha-Emitting Radioimmunoconjugate Thorium-227-DOTA-Rituximab

Purpose: To determine whether the low-dose-rate alpha-particle-emitting radioimmunoconjugate {sup 227}Th-1,4,7,10-p-isothiocyanato-benzyl-tetraazacyclododecane-1,4,7, 10-tetraacetic acid (DOTA)-rituximab can be used to inactivate lymphoma cells growing as single cells and small colonies. Methods and Materials: CD20-positive lymphoma cell lines were treated with {sup 227}Th-DOTA-rituximab for 1-5 weeks. To simulate the in vivo situation with continuous but decreasing supply of radioimmunoconjugates from the blood pool, the cells were not washed after incubation with {sup 227}Th-DOTA-rituximab, but half of the medium was replaced with fresh medium, and cell concentration and cell-bound activity were determined every other day after start of incubation. A microdosimetric model was established to estimate the average number of hits in the nucleus for different localizations of activity. Results: There was a specific targeted effect on cell growth of the {sup 227}Th-DOTA-rituximab treatment. Although the cells were not washed after incubation with {sup 227}Th-DOTA-rituximab, the average contribution of activity in the medium to the mean dose was only 6%, whereas the average contribution from activity on the cells' own surface was 78%. The mean dose rates after incubation with 800 Bq/mL {sup 227}Th-DOTA-rituximab varied from 0.01 to 0.03 cGy/min. The average delay in growing from 10{sup 5} to 10{sup 7} cells/mL was 15 days when the cells were treated with a mean absorbed radiation dose of 2 Gy alpha-particle radiation from {sup 227}Th-DOTA-rituximab, whereas it was 11 days when the cells were irradiated with 6 Gy of X-radiation. The relative biologic effect of the treatment was estimated to be 2.9-3.4. Conclusions: The low-dose-rate radioimmunoconjugate {sup 227}Th-DOTA-rituximab is suitable for inactivation of single lymphoma cells and small colonies of lymphoma cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Energy-preserving coupling of explicit particle-in-cell with Monte Carlo collisions

The particle-in-cell (PIC) and Monte Carlo collisions (MCC) methods are workhorses of many numerical simulations of physical systems. Recently, it was pointed out that, while the two methods can be exactly—or nearly—energy-conserving independently, combining the two leads to anomalous numerical heating. This paper reviews the standard explicit PIC-MCC algorithm, elucidates the origins of the anomalous numerical heating, and explains how to couple the two methods such that the anomalous numerical heating is avoided.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-151: Dosimetric Evaluation of DIR Mapped Contours for Image Guided Adaptive Radiotherapy with 4D Cone-Beam CT

Purpose: To estimate dosimetric errors resulting from using contours deformably mapped from planning CT to 4D cone beam CT (CBCT) images for image-guided adaptive radiotherapy of locally advanced non-small cell lung cancer (NSCLC). Methods: Ten locally advanced non-small cell lung cancer (NSCLC) patients underwent one planning 4D fan-beam CT (4DFBCT) and weekly 4DCBCT scans. Multiple physicians delineated the gross tumor volume (GTV) and normal structures in planning CT images and only GTV in CBCT images. Manual contours were mapped from planning CT to CBCTs using small deformation, inverse consistent linear elastic (SICLE) algorithm for two scans in each patient. Two physicians reviewed and rated the DIR-mapped (auto) and manual GTV contours as clinically acceptable (CA), clinically acceptable after minor modification (CAMM) and unacceptable (CU). Mapped normal structures were visually inspected and corrected if necessary, and used to override tissue density for dose calculation. CTV (6mm expansion of GTV) and PTV (5mm expansion of CTV) were created. VMAT plans were generated using the DIR-mapped contours to deliver 66 Gy in 33 fractions with 95% and 100% coverage (V66) to PTV and CTV, respectively. Plan evaluation for V66 was based on manual PTV and CTV contours. Results: Mean PTV V66 was 84% (range 75% – 95%) and mean CTV V66 was 97% (range 93% – 100%) for CAMM scored plans (12 plans); and was 90% (range 80% – 95%) and 99% (range 95% – 100%) for CA scored plans (7 plans). The difference in V66 between CAMM and CA was significant for PTV (p = 0.03) and approached significance for CTV (p = 0.07). Conclusion: The quality of DIR-mapped contours directly impacted the plan quality for 4DCBCT-based adaptation. Larger safety margins may be needed when planning with auto contours for IGART with 4DCBCT images. Reseach was supported by NIH P01CA116602.

60 APPLIED LIFE SCIENCES↗

Polarized 3He Gas Circulating Technologies for Neutron Analyzers

We describe the development of an integrated system for quasi-continuous operation of a large volume neutron analyzer. The system consists of a non-magnetic diaphragm compressor, a prototype large volume helium polarizer, a surrogate neutron analyzer, a non-depolarizing gas storage reservoir, a non-ferrous valve manifold for handling gas distribution, a custom rubidium-vapor gas return purifier, and wire-wound transfer lines, all of which are immersed in a two-meter external magnetic field. Over the Phase II period we focused on three major tasks required for the successful deployment of these types of systems: 1) design and implementation of gas handling hardware, 2) automation for long-term operation, and 3) improvements in polarizer performance, specifically fabrication of aluminosilicate optical pumping cells. In this report we describe the design, implementation, and testing of the gas handling hardware. We describe improved polarizer performance resulting from improved cell materials and fabrication methods. These improvements yielded valved 8.5 liter cells with relaxation times greater than 12 hours. Pumping this cell with 1500W laser power with 1.25nm linewidth yielded peak polarizations of 60%, measured both inside and outside the polarizer. Fully narrowing this laser to 0.25nm, demonstrated separately on one stack of the four, would have allowed 70% polarization with this cell. We demonstrated the removal of 5 liters of polarized helium from the polarizer with no measured loss of polarization. We circulated the gas through a titanium-clad compressor with polarization loss below 3% per pass. We also prepared for the next phase of development by refining the design of the polarizer so that it can be engineer-certified for pressurized operation. The performance of our system far exceeds comparable efforts elsewhere.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Terrestrial photovoltaic measurements workshop

Workshop proceedings review basic methodology for measurements and calibration of solar cells. Also included are decisions concerning interim method for terrestrial solar cell measurements in order that results may be correlated between organizations doing solar cell research.

Source record↗