Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Efficient prediction of attosecond two-colour pulses from an X-ray free-electron laser with machine learning

Abstract X-ray free-electron lasers are sources of coherent, high-intensity X-rays with numerous applications in ultra-fast measurements and dynamic structural imaging. Due to the stochastic nature of the self-amplified spontaneous emission process and the difficulty in controlling injection of electrons, output pulses exhibit significant noise and limited temporal coherence. Standard measurement techniques used for characterizing two-coloured X-ray pulses are challenging, as they are either invasive or diagnostically expensive. In this work, we employ machine learning methods such as neural networks and decision trees to predict the central photon energies of pairs of attosecond fundamental and second harmonic pulses using parameters that are easily recorded at the high-repetition rate of a single shot. Using real experimental data, we apply a detailed feature analysis on the input parameters while optimizing the training time of the machine learning methods. Our predictive models are able to make predictions of central photon energy for one of the pulses without measuring the other pulse, thereby leveraging the use of the spectrometer without having to extend its detection window. We anticipate applications in X-ray spectroscopy using XFELs, such as in time-resolved X-ray absorption and photoemission spectroscopy, where improved measurement of input spectra will lead to better experimental outcomes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deep learning with mixup augmentation for improved pore detection during additive manufacturing

In additive manufacturing (AM), process defects such as keyhole pores are difficult to anticipate, affecting the quality and integrity of the AM-produced materials. Hence, considerable efforts have aimed to predict these process defects by training machine learning (ML) models using passive measurements such as acoustic emissions. This work considered a dataset in which keyhole pores of a laser powder bed fusion (LPBF) experiment were identified using X-ray radiography and then registered both in space and time to acoustic measurements recorded during the LPBF experiment. Due to AM’s intrinsic process controls, where a pore-forming event is relatively rare, the acoustic datasets collected during monitoring include more non-pores than pores. In other words, the dataset for ML model development is imbalanced. Moreover, this imbalanced and sparse data phenomenon remains ubiquitous across many AM monitoring schemes since training data is nontrivial to collect. Hence, we propose a machine learning approach to improve this dataset imbalance and enhance the prediction accuracy of pore-labeled data. Specifically, we investigate how data augmentation helps predict pores and non-pores better. This imbalance is improved using recent advances in data augmentation called Mixup, a weak-supervised learning method. Convolutional neural networks (CNNs) are trained on original and augmented datasets, and an appreciable increase in performance is reported when testing on five different experimental trials. When ML models are trained on original and augmented datasets, they achieve an accuracy of 95% and 99% on test datasets, respectively. We also provide information on how dataset size affects model performance. Lastly, we investigate the optimal Mixup parameters for augmentation in the context of CNN performance.

36 MATERIALS SCIENCE↗

Three- and four-body nonadditivities in nucleic acid tetramers: a CCSD(T) study

Three- and four-body nonadditivities in the uracil tetramer (in DNA-like geometry) and the GC step (in crystal geometry) were investigated at various levels of the wave-function theory: HF, MP2, MP3, L-CCD, CCSD and CCSD(T). All of the calculations were performed using the 6-31G**(0.25,0.15) basis set, whereas the HF, MP2 and the MP3 nonadditivities were, for the sake of comparison, also determined with the much larger aug-cc-pVDZ basis set. The HF and MP2 levels do not provide reliable values for many-body terms, making it necessary to go beyond the MP2 level. The benchmark CCSD(T) three- and four-body nonadditivities are reasonably well reproduced at the MP3 level, and almost quantitative agreement is obtained (fortuitously) either on the L-CCD level or as an average of the MP3 and the CCSD results. Reliable values of many-body terms (especially their higher-order correlation contributions) are obtained already when the rather small 6-31G**(0.25,0.15) basis set is used. The four-body term is much smaller when compared to the three-body terms, but it is definitely not negligible, e.g. in the case of the GC step it represents about 16% of all of the three- and four-body terms. While investigating the geometry dependence of many-body terms for the GG step at the MP3/6-31G**(0.25,0.15) level, we found that it is necessary to include at least three-body terms in the determination of optimal geometry parameters.

59 BASIC BIOLOGICAL SCIENCES↗

Direct and rapid uranium isotopic analysis of environmental sample swipes via microextraction – LS-APGD/Orbitrap mass spectrometry

Accurate and precise isotopic analysis of actinides collected on environmental sample swipes from within nuclear facilities is an important safeguarding measure for detecting undeclared materials and activities. Traditional isotope ratio (IR) analysis of actinides using a bulk digestion approach can be laborious and time-consuming. Recently, direct analysis of environmental swipe samples using a microextraction approach has been explored as an alternative to conventional bulk digestion methods. The present study further evaluates this approach for accurate and precise isotopic analysis of uranium (U) in cotton swipe samples using the liquid sampling-atmospheric pressure glow discharge (LS-APGD)/Orbitrap-FTMS Booster detection system. The instrumental parameters were optimized, and quantitative capabilities were demonstrated through excellent linearity (R2 = 0.99) across a deposited mass range of 1 to 500 ng, with a limit of detection of 90 pg (in a 2 × 4 mm region) for total U; well below typical U concentrations (ng–mg range) in environmental sample swipes. The 235U/238U ratio showed excellent accuracy (−0.3% relative difference from the certificate value), with ∼20× improvement over previous microextraction-Orbitrap methods. Precision (∼1% relative standard deviation) was also greatly enhanced by ∼5×. This study also demonstrates that figures of merit achieved with neat U solution were not highly degraded when various external interfering elements/matrices were introduced. Finally, the developed method was successfully applied to analyze practical swipe samples representative of laboratory and outdoor environments. The presented figures of merit and applicability to practical samples further validate the capability of the platform for rapid analysis (<7 minutes) of environmental swipe samples.

Shrestha, Suraj [Clemson University, SC]↗

Construction of a Generalized Gradient Approximation by Restoring the Density-gradient Expansion and Enforcing a Tight Lieb-Oxford Bound

The research described in this product was performed in part in the Environmental Molecular Sciences Laboratory, a national scientific user facility sponsored by the Department of Energy's Office of Biological and Environmental Research and located at Pacific Northwest National Laboratory. Recently, a generalized gradient approximation (GGA) to the density functional, called PBEsol, was optimized (one parameter) against the jellium-surface exchange-correlation energies, and this, in conjunction with changing another parameter to restore the first-principles gradient expansion for exchange, was sufficient to yield accurate lattice constants of solids. Here, we construct a new GGA that has no empirical parameters, that satisfies one more exact constraint than PBEsol, and that performs 20% better for the lattice constants of 18 previously studied solids, although it does not improve on PBEsol for molecular atomization energies (a property that neither functional was designed for). The new GGA is exact through second order, and it is called the second-order generalized gradient approximation (SOGGA). The SOGGA functional also differs from other GGAs in that it enforces a tighter Lieb–Oxford bound. SOGGA and other functionals are compared to a diverse set of lattice constants, bond distances, and energetic quantities for solids and molecules (this includes the first test of the M06-L meta-GGA for solid-state properties). We find that classifying density functionals in terms of the magnitude µ of the second-order coefficient of the density gradient expansion of the exchange functional not only correlates their behavior for predicting lattice constants of solids versus their behavior for predicting small-molecule atomization energies, as pointed out by Perdew and co-workers

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sulphide Ga{sub x}Ge{sub 25-x}Sb{sub 10}S{sub 65(x=0,5)} sputtered films: Fabrication and optical characterizations of planar and rib optical waveguides

We report the fabrication and the physical and optical characterizations of sulphide Ga{sub x}Ge{sub 25-x}Sb{sub 10}S{sub 65(x=0,5)} rib waveguides. High quality films fabricated on SiO{sub 2}/Si wafer substrates were obtained using the sputtering magnetron rf deposition method. The slab waveguides obtained without annealing present propagation losses of about 0.6 dB/cm at 1550 nm. These optical losses are not important for implementation in optical devices based on silicon-on-insulator or polymer, for instance, atomic force microscopy measurements revealed low interface roughness between the different media (substrate/film and film/air). Reactive ion etching was used to pattern rib waveguides between 2 and 300 {mu}m wide. The parameters were optimized to obtain a dry etching process that had low surface roughness, vertical sidewalls, etch depth of more than 1 {mu}m, and reasonable etching rate. This technique was used to fabricate Y optical junctions for optical interconnections on chalcogenide amorphous films. Their optical transmission was demonstrated by optical near field of guided modes and optical losses were measured and discussed.

36 MATERIALS SCIENCE↗

Elongation of extreme ultraviolet (at 13.5 nm) emission with time-of-flight controlled discharges and lateral fuel injection

A way toward a quasicontinuous extreme ultraviolet (EUV) radiation source is proposed and explored. Tin and lithium vapor discharges with the lateral laser-ablation injection are experimentally studied as possible efficient sources of quasicontinuous emission of EUV radiation at a wavelength of 13.5 nm. It is shown that the time-of-flight control of optimal plasma parameters by means of varying ablating laser pulse parameters provides a considerable elongation of maximal-power EUV emission with an overall efficiency of 0.1% and with an energy output exceeding 1% of the energy deposited in the discharge plasma. Along with a high average power and a stable position, such an emitter may have its size small enough to be used in the projection lithography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High brightness extreme ultraviolet (at 13.5 nm) emission from time-of-flight controlled discharges with coaxial fuel injection

Extreme ultraviolet (EUV) emission from discharge produced plasma with the coaxial injection of fuel vapor (tin and lithium) produced by laser ablation is experimentally studied. Multiple plasma pinches preceding a strong and long recombination radiation of EUV are observed in the first half cycle of a sinusoidal discharge current. Due to the time-of-flight control type of the discharge, the shape of pinch radiation pulses is almost identical. With the coaxial injection of time-of-flight controlled discharges, the highest brightness of EUV emission (maximum extracted energy of 244.3 mJ/2{pi} sr per pulse with the emitter size of {approx}1x0.3 mm{sup 2} in full width at half maximum) is provided with efficiency exceeding 2% of deposited energy into the plasma (or 1% of dissipated energy in the discharge) due to a much better matching with the optimal plasma parameters in the recombination regime and a decrease in the off-duty factor. Stability of emitting plasma of the repetitive pinches is essentially improved with use of a second laser pulse.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultrafast imaging of transient electronic plasmas produced in conditions of femtosecond waveguide writing in dielectrics

Femtosecond laser-induced plasmas in bulk dielectrics are imaged under waveguide writing conditions, for different polarizations, pulse durations, and processing depths, and their temporal evolution is measured using ultrafast pump-probe microscopy. The irradiation beam profile is elliptically shaped yielding a disklike focal volume. We demonstrate for doped phosphate glass that increasing the pulse duration improves the spatial distribution of deposited energy by minimizing beam filamentation and prefocal depletion effects. As a consequence, energy deposition in the desired volume is greatly enhanced. Our results identify key parameters for optimizing femtosecond laser processing of dielectrics and different strategies to minimize energy loss channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase contrast imaging simulation and measurements using polychromatic sources with small source-object distances

Phase contrast imaging is a technique widely used in synchrotron facilities for nondestructive analysis. Such technique can also be implemented through microfocus x-ray tube systems. Recently, a relatively new type of compact, quasimonochromatic x-ray sources based on Compton backscattering has been proposed for phase contrast imaging applications. In order to plan a phase contrast imaging system setup, to evaluate the system performance and to choose the experimental parameters that optimize the image quality, it is important to have reliable software for phase contrast imaging simulation. Several software tools have been developed and tested against experimental measurements at synchrotron facilities devoted to phase contrast imaging. However, many approximations that are valid in such conditions (e.g., large source-object distance, small transverse size of the object, plane wave approximation, monochromatic beam, and Gaussian-shaped source focal spot) are not generally suitable for x-ray tubes and other compact systems. In this work we describe a general method for the simulation of phase contrast imaging using polychromatic sources based on a spherical wave description of the beam and on a double-Gaussian model of the source focal spot, we discuss the validity of some possible approximations, and we test the simulations against experimental measurements using a microfocus x-ray tube on three types of polymers (nylon, poly-ethylene-terephthalate, and poly-methyl-methacrylate) at varying source-object distance. It will be shown that, as long as all experimental conditions are described accurately in the simulations, the described method yields results that are in good agreement with experimental measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quasimonoenergetic proton beam from ultraintense-laser irradiation of a target with holed backside

A scheme for producing quasimonoenergetic proton beams is presented. In the scheme, a thin solid target with a tiny hole on its backside is employed. The optimal hole diameter is of the order of the laser spot size so that a localized uniform sheath field can be generated in the hole. Particle-in-cell simulations demonstrate that the highly localized uniform fields can produce monoenergetic target normal sheath acceleration protons in the hole. The transverse electric fields can well suppress the transverse divergence of the protons. The dependence of the proton beam quality on the focal radius and hole structure is also investigated. This special tailed target together with optimized laser parameters can serve as sources for collimated as well as quasimonoenergetic proton beams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DETECTION OF LACK OF FUSION WELD DEFECTS BY RADIOGRAPHY

In this work, radiography was employed as the NDT technique for detection of flaws in circumferential girth welds of steel pipelines used in offshore installations in the petroleum industry. The kind of defect specifically focused was lack of fusion. It is currently accepted in the literature that radiography is not as sensitive as ultrasonics to detect lack of fusion defects. Unfortunately, the radiographic inspection can barely detect lack of fusion and only when it is associated to inclusions and voids of considerable size. However, in a previous article ('Reliability of radiographic inspection of steel pipeline girth welds', QNDE Conference, 2007), the authors showed that it is possible to detect lack of fusion defects if, in the radiographic tests, the angle of incidence is the same angle that the weld bevel makes with the test piece surface, which means lowering the angle of disorientation between the flaw and the radiographic beam. However, no concerns were made to sizing the defects. Computational simulation was used with XRSIM software to establish the optimal radiographic parameters to reach the lower limit for detection for this kind of defect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Use of Sequential Injection Analysis to construct a Potentiometric Electronic Tongue: Application to the Multidetermination of Heavy Metals

An automated potentiometric electronic tongue (ET) was developed for the quantitative determination of heavy metal mixtures. The Sequential Injection Analysis (SIA) technique was used in order to automate the obtaining of input data, and the combined response was modeled by means of Artificial Neural Networks (ANN). The sensor array was formed by four sensors: two based on chalcogenide glasses Cd sensor and Cu sensor, and the rest on poly(vinyl chloride) membranes Pb sensor and Zn sensor. The Ion Selective Electrode (ISE) sensors were first characterized with respect to one and two analytes, by means of high-dimensionality calibrations, thanks to the use of the automated flow system; this characterization enabled an interference study of great practical utility. To take profit of the dynamic nature of the sensor's response, the kinetic profile of each sensor was compacted by Fast Fourier Transform (FFT) and the extracted coefficients were used as inputs for the ANN in the multidetermination applications. In order to identify the ANN which provided the best model of the electrode responses, some of the network parameters were optimized. Finally analyses were performed employing synthetic samples and water samples of the river Ebro; obtained results were compared with reference methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computation of methodology-independent single-ion solvation properties from molecular simulations. IV. Optimized Lennard-Jones interaction parameter sets for the alkali and halide ions in water

The raw single-ion solvation free energies computed from atomistic (explicit-solvent) simulations are extremely sensitive to the boundary conditions and treatment of electrostatic interactions used during these simulations. However, as shown recently [M. A. Kastenholz and P. H. Huenenberger, J. Chem. Phys. 124, 224501 (2006); M. M. Reif and P. H. Huenenberger, J. Chem. Phys. 134, 144103 (2010)], the application of appropriate correction terms permits to obtain methodology-independent results. The corrected values are then exclusively characteristic of the underlying molecular model including in particular the ion-solvent van der Waals interaction parameters, determining the effective ion size and the magnitude of its dispersion interactions. In the present study, the comparison of calculated (corrected) hydration free energies with experimental data (along with the consideration of ionic polarizabilities) is used to calibrate new sets of ion-solvent van der Waals (Lennard-Jones) interaction parameters for the alkali (Li{sup +}, Na{sup +}, K{sup +}, Rb{sup +}, Cs{sup +}) and halide (F{sup -}, Cl{sup -}, Br{sup -}, I{sup -}) ions along with either the SPC or the SPC/E water models. The experimental dataset is defined by conventional single-ion hydration free energies [Tissandier et al., J. Phys. Chem. A 102, 7787 (1998); Fawcett, J. Phys. Chem. B 103, 11181] along with three plausible choices for the (experimentally elusive) value of the absolute (intrinsic) hydration free energy of the proton, namely, {Delta}G{sub hyd} {sup O-minus} [H{sup +}]=-1100, -1075 or -1050 kJ mol{sup -1}, resulting in three sets L, M, and H for the SPC water model and three sets L{sub E}, M{sub E}, and H{sub E} for the SPC/E water model (alternative sets can easily be interpolated to intermediate {Delta}G{sub hyd} {sup O-minus} [H{sup +}] values). The residual sensitivity of the calculated (corrected) hydration free energies on the volume-pressure boundary conditions and on the effective ionic radius entering into the calculation of the correction terms is also evaluated and found to be very limited. Ultimately, it is expected that comparison with other experimental ionic properties (e.g., derivative single-ion solvation properties, as well as data concerning ionic crystals, melts, solutions at finite concentrations, or nonaqueous solutions) will permit to validate one specific set and thus, the associated {Delta}G{sub hyd} {sup O-minus} [H{sup +}] value (atomistic consistency assumption). Preliminary results (first-peak positions in the ion-water radial distribution functions, partial molar volumes of ionic salts in water, and structural properties of ionic crystals) support a value of {Delta}G{sub hyd} {sup O-minus} [H{sup +}] close to -1100 kJ{center_dot}mol{sup -1}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single quantum dot emission at telecom wavelengths from metamorphic InAs/InGaAs nanostructures grown on GaAs substrates

We report on the growth by molecular beam epitaxy and the study by atomic force microscopy and photoluminescence of low density metamorphic InAs/InGaAs quantum dots. subcritical InAs coverages allow to obtain 10{sup 8} cm{sup -2} dot density and metamorphic In{sub x}Ga{sub 1-x}As (x=0.15,0.30) confining layers result in emission wavelengths at 1.3 {mu}m. We discuss optimal growth parameters and demonstrate single quantum dot emission up to 1350 nm at low temperatures, by distinguishing the main exciton complexes in these nanostructures. Reported results indicate that metamorphic quantum dots could be valuable candidates as single photon sources for long wavelength telecom windows.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Break-out afterburner ion acceleration in the longer laser pulse length regime

Kinetic simulations of break-out-afterburner (BOA) ion acceleration from nm-scale targets are examined in a longer pulse length regime than studied previously. It is shown that when the target becomes relativistically transparent to the laser, an epoch of dramatic acceleration of ions occurs that lasts until the electron density in the expanding target reduces to the critical density in the non-relativistic limit. For given laser parameters, the optimal target thickness yielding the highest maximum ion energy is one in which this time window for ion acceleration overlaps with the intensity peak of the laser pulse. A simple analytic model of relativistically induced transparency is presented for plasma expansion at the time-evolving sound speed, from which these times may be estimated. The maximum ion energy attainable is controlled by the finite acceleration volume and time over which the BOA acts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microbubbles as contrast agent for in-line x-ray phase-contrast imaging

In the present study, we investigated the potential of gas-filled microbubbles as contrast agents for in-line x-ray phase-contrast imaging (PCI) in biomedical applications. When imaging parameters are optimized, the microbubbles function as microlenses that focus the incoming x-rays to form bright spots, which can significantly enhance the image contrast. Since microbubbles have been shown to be safe contrast agents in clinical ultrasonography, this contrast-enhancement procedure for PCI may have promising utility in biomedical applications, especially when the dose of radiation is a serious concern. In this study, we performed both numerical simulations and ex vivo experiments to investigate the formation of the contrast and the effectiveness of microbubbles as contrast agents in PCI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bilayer Polymer Solar Cells with Improved Power Conversion Efficiency and Enhanced Spectrum Coverage

We demonstrate the construction of an efficient bilayer polymer solar cell comprising of Poly(3-hexylthiophene)(P3HT) as a p-type semiconductor and asymmetric fullerene (C{sub 70}) as n-type counterparts. The bilayer configuration was very efficient compared to the individual layer performance and it behaved like a regular p-n junction device. The photovoltaic characteristic of the bilayers were studied under AM 1.5 solar radiation and the optimized device parameters are the following: Voc = 0.5V, Jsc = 10.1 mA/cm{sup 2}, FF = 0.60 and power conversion efficiency of 3.6 %. A high fill factor of {approx}0.6 was achieved, which is only slightly reduced at very intense illumination. Balanced mobility between p-and n-layers is achieved which is essential for achieving high device performance. Correlation between the crystallinity, morphology and the transport properties of the active layers is established. The External quantum efficiency (EQE) spectral distribution of the bilayer devices with different processing solvents correlates well with the trends of short circuit current densities (J{sub sc}) measured under illumination. Efficiency of the bilayer devices with rough P3HT layer was found to be about 3 times higher than those with a planar P3HT surface. Hence it is desirable to have a larger grains with a rough surface of P3HT layer for providing larger interfacial area for the exciton dissociation.

14 SOLAR ENERGY↗