Search NASA⌕ Search

SEARCH · Search NASA

Results for “protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

A Phase II Study of Preradiotherapy Chemotherapy Followed by Hyperfractionated Radiotherapy for Newly Diagnosed High-Risk Medulloblastoma/Primitive Neuroectodermal Tumor: A Report From the Children's Oncology Group (CCG 9931)

Purpose: To verify feasibility and monitor progression-free survival and overall survival in children with high-risk medulloblastoma and noncerebellar primitive neuroectodermal tumors (PNETs) treated in a Phase II study with preradiotherapy chemotherapy (CHT) followed by high-dose, hyperfractionated craniospinal radiotherapy (CSRT). Methods and Materials: Eligibility criteria included age >3 years at diagnosis, medulloblastoma with either high M stage and/or >1.5 cm{sup 2} postoperative residual disease, and all patients with noncerebellar PNET. Treatment was initiated with five alternating monthly cycles of CHT (A [cisplatin, cyclophosphamide, etoposide, and vincristine], B [carboplatin and etoposide], A, B, and A) followed by hyperfractionated CSRT (40 Gy) with a boost to the primary tumor (72 Gy) given in twice-daily 1-Gy fractions. Results: The valid study group consisted of 124 patients whose median age at diagnosis was 7.8 years. Eighty-four patients (68%) completed the entire protocol according to study guidelines (within 9 months), and the median time to complete CSRT was 1.6 months. Major reasons for failure to complete CHT included progressive disease (17%) and toxic death (2.4%). The 5-year progression-free survival and overall survival rates were 43% {+-} 5% and 52% {+-} 5%, respectively. No significant differences were detected in subset analysis related to response to CHT, site of primary tumor, postoperative residual disease, or M stage. Conclusions: The feasibility of this intensive multimodality protocol was confirmed, and response to pre-RT CHT did not impact on survival. Survival data from this protocol can not be compared with data from other studies, given the protocol design.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Internal Audit of a Comprehensive IMRT Program for Prostate Cancer: A Model for Centers in Developing Countries?

Purpose: With improving regional prosperity, significant capital investments have been made to rapidly expand radiotherapy capacity across Southeast Asia. Yet little has been reported on the implementation of adequate quality assurance (QA) in patient management. The objective of this study is to perform an in-depth QA assessment of our definitive intensity-modulated radiotherapy (IMRT) program for prostate cancer since its inception. Methods and Materials: The department's prostate IMRT program was modeled after that of University of California San Francisco. A departmental protocol consisting of radiotherapy volume/dose and hormone sequencing/duration and a set of 18 dose objectives to the target and critical organs were developed, and all plans were presented at the weekly departmental QA rounds. All patients treated with definitive IMRT for nonmetastatic prostate cancer were retrospectively reviewed. Protocol adherence, dosimetry data, toxicities, and outcomes were evaluated. Results: Since 2005, 76 patients received IMRT: 54 with whole-pelvis and 22 with prostate-only treatment. Of the 1,140 recorded dosimetric end points, 39 (3.3%) did not meet the protocol criteria. At QA rounds, no plans required a revision. Only one major protocol violation was observed. Two and two cases of Grade 3-4 acute and late toxicities, respectively, were observed. Five (8.8%) patients developed proctitis, but only one required argon laser therapy. Conclusions: Our comprehensive, practice-adapted QA measures appeared to ensure that we were able to consistently generate conforming IMRT plans with acceptable toxicities. These measures can be easily integrated into other clinics contemplating on developing such a program.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Translational and Rotational Errors on Complex Dose Distributions With Off-Line and On-Line Position Verification

Purpose: To investigate the influence of translational and rotational errors on prostate intensity-modulated radiotherapy (IMRT) with an integrated boost to the tumor and to evaluate the effect of the use of an on-line correction protocol. Methods and Materials: For 19 patients, who had been treated with prostate IMRT and fiducial marker-based position verification, highly inhomogeneous IMRT plans, including an integrated tumor boost, were made using varying margins (2, 4, 6, and 8 mm). The measured translational and rotational errors were used to calculate the dose using two positioning strategies: an off-line and an on-line protocol to correct the translational shifts. The estimated dose to the targets and the organs at risk was compared with the intended dose. Results: Residual deviations after off-line correction led to statistically significant, but very small, reductions in dose coverage. Even when a 2-mm margin was used, the average reduction in dose to 99% of the volume was 1.4 {+-} 1.9 Gy for the tumor, 1.5 {+-} 1.5 Gy for the prostate without seminal vesicles (boost volume), and 4.3 {+-} 4.6 Gy, including the seminal vesicles (clinical target volume). Patients with large systematic rotational errors demonstrated a substantial decrease in dose, especially for the clinical target volume. If an on-line correction protocol was used, the average mean dose and dose to 99% of the volume of the targets improved. However, the extensive dose reduction for patients with large rotational errors barely recovered with on-line correction. Conclusion: For complex prostate IMRT with an integrated tumor boost, the use of an on-line correction protocol yields little improvement without the correction of rotational errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Retrospective, Multicenter Study of the Tolerance of Induction Chemotherapy With Docetaxel, Cisplatin, and 5-Fluorouracil Followed by Radiotherapy With Concomitant Cetuximab in 46 Cases of Squamous Cell Carcinoma of the Head and Neck

Purpose: To investigate, in a multicenter study, the tolerance of induction chemotherapy (ICT) and external radiotherapy (ERT) with concomitant cetuximab in the treatment of patients with squamous cell carcinoma of the head and neck (SCCHN). Patients and Methods: Clinical data from 46 patients with Stage III or IV nonmetastatic SCCHN who received docetaxel, cisplatin, and 5-fluorouracil as ICT, followed by ERT with concomitant cetuximab, were retrospectively analyzed. Clinical safety (weight, allergy, mucositis, and dermatitis) and paraclinical safety (levels of hemoglobin, polynuclear neutrophils, and creatinine clearance) were studied. The primary objective was the proportion of patients who completed the protocol. Results: The percentage of patients completing ICT was 73.9%, ERT 93.5%, and cetuximab 69.6%. Induction chemotherapy was better tolerated than that previously reported. The rates of temporary suspensions of radiation (39.1%, mean duration of 13 days) and hospitalization (26.1%) during ERT with concomitant cetuximab were high. Weight loss during treatment (21.4% of patients lost >10% of their body weight), radiodermatitis, and radiomucositis were the main causes of temporary suspension of treatment, although Grade 4 dermatitis was not experienced. There were no allergic reactions to cetuximab. Conclusion: The completed protocol rate for SCCHN patients receiving ICT and ERT with concomitant cetuximab is high and the toxicity acceptable. Future improvements to protocol will be possible through early action and systematic implementation of nutritional support coupled with antibiotic treatment upon the first signs of radiodermatitis. These data could be useful for prospective studies on the safety and efficacy of this protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Phase II Study of Bevacizumab in Combination With Definitive Radiotherapy and Cisplatin Chemotherapy in Untreated Patients With Locally Advanced Cervical Carcinoma: Preliminary Results of RTOG 0417

Purpose: Concurrent cisplatin-based chemoradiotherapy (CRT) is the standard treatment for locally advanced cervical cancer. RTOG 0417 was a Phase II study exploring the safety and efficacy of the addition of bevacizumab to standard CRT. Methods and Materials: Eligible patients with bulky tumors (Stage IB-IIIB) were treated with once-weekly cisplatin (40 mg/m{sup 2}) chemotherapy and standard pelvic radiotherapy and brachytherapy. Bevacizumab was administered at 10 mg/kg intravenously every 2 weeks for three cycles. Treatment-related serious adverse event (SAE) and other adverse event (AE) rates within the first 90 days from treatment start were determined. Treatment-related SAEs were defined as any Grade {>=}4 vaginal bleeding or thrombotic event or Grade {>=}3 arterial event, gastrointestinal (GI) bleeding, or bowel/bladder perforation, or any Grade 5 treatment-related death. Treatment-related AEs included all SAEs and Grade 3 or 4 GI toxicity persisting for >2 weeks despite medical intervention, Grade 4 neutropenia or leukopenia persisting for >7 days, febrile neutropenia, Grade 3 or 4 other hematologic toxicity, and Grade 3 or 4 GI, renal, cardiac, pulmonary, hepatic, or neurologic AEs. All AEs were scored using the National Cancer Institute Common Terminology Criteria (CTCAE) v 3.0 (MedDRA version 6.0). Results: A total of 60 patients from 28 institutions were enrolled between 2006 and 2009, and of these, 49 patients were evaluable. The median follow-up was 12.4 months (range, 4.6-31.4 months).The median age was 45 years (range, 22-80 years). Most patients had FIGO Stage IIB (63%) and were of Zubrod performance status of 0 (67%). 80% of cases were squamous. There were no treatment-related SAEs. There were 15 (31%) protocol-specified treatment-related AEs within 90 days of treatment start; the most common were hematologic (12/15; 80%). 18 (37%) occurred during treatment or follow-up at any time. 37 of the 49 patients (76%) had cisplatin and bevacizumab administered per protocol, and 46 of the 49 (94%) had both external beam and brachytherapy administered per protocol or with acceptable variation. Conclusion: Bevacizumab in addition to standard pelvic chemoradiotherapy for locally advanced cervical cancer is feasible and safe with respect to the protocol-specified treatment-related SAEs and AEs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes of Patients With Revised Stage I Clear Cell Sarcoma of Kidney Treated in National Wilms Tumor Studies 1-5

Purpose: To report the clinical outcomes of children with revised stage I clear cell sarcoma of the kidney (CCSK) using the National Wilms Tumor Study Group (NWTS)-5 staging criteria after multimodality treatment on NWTS 1-5 protocols. Methods and Materials: All CCSK patients enrolled in the National Wilms Tumor Study Group protocols had their pathology slides reviewed, and only those determined to have revised stage I tumors according to the NWTS-5 staging criteria were included in the present analysis. All patients were treated with multimodality therapy according to the NWTS 1-5 protocols. Results: A total of 53 children were identified as having stage I CCSK. All patients underwent primary surgery with radical nephrectomy. The chemotherapy regimens used were as follows: regimen A, C, F, or EE in 4 children (8%); regimen DD or DD4A in 33 children (62%); regimen J in 4 children (8%); and regimen I in 12 children (22%). Forty-six patients (87%) received flank radiation therapy (RT). Seven children (13%) did not receive flank RT. The median delay between surgery and the initiation of RT was 9 days (range, 3-61). The median RT dose was 10.8 Gy (range, 10-36). The flank RT doses were as follows: 10.5 or 10.8 Gy in 25 patients (47%), 11-19.9 Gy in 2 patients (4%), 20-29.9 Gy in 9 patients (17%), and 30-40 Gy in 10 patients (19%). The median follow-up for the entire group was 17 years (range, 2-36). The relapse-free and cancer-specific survival rate was 100% at the last follow-up examination. Conclusions: The present results have demonstrated that children with revised stage I CCSK using the NWTS-5 staging criteria have excellent survival rates despite the use of varying RT doses and chemotherapy regimens in the NWTS 1-5 protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-Beam Computed Tomography–Guided Positioning of Laryngeal Cancer Patients with Large Interfraction Time Trends in Setup and Nonrigid Anatomy Variations

Purpose: To investigate interfraction setup variations of the primary tumor, elective nodes, and vertebrae in laryngeal cancer patients and to validate protocols for cone beam computed tomography (CBCT)-guided correction. Methods and Materials: For 30 patients, CBCT-measured displacements in fractionated treatments were used to investigate population setup errors and to simulate residual setup errors for the no action level (NAL) offline protocol, the extended NAL (eNAL) protocol, and daily CBCT acquisition with online analysis and repositioning. Results: Without corrections, 12 of 26 patients treated with radical radiation therapy would have experienced a gradual change (time trend) in primary tumor setup ≥4 mm in the craniocaudal (CC) direction during the fractionated treatment (11/12 in caudal direction, maximum 11 mm). Due to these trends, correction of primary tumor displacements with NAL resulted in large residual CC errors (required margin 6.7 mm). With the weekly correction vector adjustments in eNAL, the trends could be largely compensated (CC margin 3.5 mm). Correlation between movements of the primary and nodal clinical target volumes (CTVs) in the CC direction was poor (r{sup 2}=0.15). Therefore, even with online setup corrections of the primary CTV, the required CC margin for the nodal CTV was as large as 6.8 mm. Also for the vertebrae, large time trends were observed for some patients. Because of poor CC correlation (r{sup 2}=0.19) between displacements of the primary CTV and the vertebrae, even with daily online repositioning of the vertebrae, the required CC margin around the primary CTV was 6.9 mm. Conclusions: Laryngeal cancer patients showed substantial interfraction setup variations, including large time trends, and poor CC correlation between primary tumor displacements and motion of the nodes and vertebrae (internal tumor motion). These trends and nonrigid anatomy variations have to be considered in the choice of setup verification protocol and planning target volume margins. eNAL could largely compensate time trends with minor prolongation of fraction time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rectal Toxicity After Proton Therapy For Prostate Cancer: An Analysis of Outcomes of Prospective Studies Conducted at the University of Florida Proton Therapy Institute

Purpose: Study goals were to characterize gastrointestinal effects of proton therapy (PT) in a large cohort of patients treated for prostate cancer, identify factors associated with rectal bleeding (RB), and compare RB between patients receiving investigational protocols versus those in outcome-tracking protocols. Methods and Materials: A total of 1285 consecutive patients were treated with PT between August 2006 and May 2010. Potential pre-existing clinical and treatment-related risk factors for rectal toxicity were recorded. Common Terminology Criteria for Adverse Events version 3.0 was used to score toxicity. Results: Transient RB was the predominant grade 2 or higher (GR2+) toxicity after PT, accounting for 95% of gastrointestinal events. GR1 RB occurred in 217 patients (16.9%), GR2 RB in 187 patients (14.5%), and GR3 in 11 (0.9%) patients. There were no GR4 or GR5 events. Univariate analyses showed correlations between GR2+ RB and anticoagulation therapy (P=.008) and rectal and rectal wall dose-volume histogram (DVH) parameters (P<.001). On multivariate analysis, anticoagulation therapy (P=.0034), relative volume of rectum receiving 75 Gy (V75; P=.0102), and relative rectal wall V75 (P=.0017) were significant predictors for G2+ RB. Patients treated with investigational protocols had toxicity rates similar to those receiving outcome-tracking protocols. Conclusions: PT was associated with a low rate of GR2+ gastrointestinal toxicity, predominantly transient RB, which was highly correlated with anticoagulation and rectal DVH parameters. Techniques that limit rectal exposure should be used when possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High throughput structure–property relationship for additively manufactured 316L/IN625 alloy mixtures leveraging 2-step Bayesian estimation

While the fabrication of graded materials by directed energy deposition (DED) has led to accelerated materials discovery, the ability to rapidly explore sufficiently large material composition spaces is limited due to the time-intensive nature of conventional materials characterization techniques. The present study investigates the viability of small punch test (SPT) protocols for rapidly evaluating DED-fabricated alloy mixtures of stainless steel 316L (316L) and Inconel 625 (IN625). The SPT protocols evaluated in this study include both the recently established two-step Bayesian estimation framework as well as the empirical relationships established in prior literature. It is shown that these protocols are capable of reliably and quantitatively tracking the changes in the mechanical properties of the alloy mixtures studied. Enhancement of mechanical properties was observed with the addition of IN625 to 316L, which is attributed to the austenite stabilization in the matrix and the formation of fine δ - Ni3Nb precipitates. It is shown that CALPHAD-based Scheil model simulations predicted the formation of different precipitate phases for each composition. The novel protocols presented in this paper open new avenues for high throughput material explorations for additive manufacturing.

2-step Bayesian estimation↗

Dosimetric evaluation of a three-phase adaptive radiotherapy for nasopharyngeal carcinoma using helical tomotherapy

Adaptive radiotherapy (ART) has been introduced to correct the radiation-induced anatomic changes in head and neck cases during a treatment course. This study evaluated the potential dosimetric benefits of applying a 3-phase adaptive radiotherapy protocol in nasopharyngeal carcinoma (NPC) patients compared with the nonadaptive single-phase treatment protocol. Ten NPC patients previously treated with this 3-phase radiation protocol using Hi-Art Tomotherapy were recruited. Two new plans, PII-ART and PIII-ART, were generated based on the up-to-date computed tomography (CT) images and contours and were used for treatment in phase two (PII; after 25th fraction) and phase three (PIII; after 35th fraction), respectively. To simulate the situation of no replanning, 2 hybrid plans denoted as PII-NART and PIII-NART were generated using the original contours pasted on the PII- and PIII-CT sets by CT-CT fusion. Dosimetric comparisons were made between the NART plans and the corresponding ART plans. In both PII- and PIII-NART plans, the doses to 95% of all the target volumes (D{sub 95}) were increased with better dose uniformity, whereas the organs at risk (OARs) received higher doses compared with the corresponding ART plans. Without replanning, the total dose to 1% of brainstem and spinal cord (D{sub 1}) significantly increased 7.87 {+-} 7.26% and 10.69 {+-} 6.72%, respectively (P = 0.011 and 0.001, respectively), in which 3 patients would have these structures overdosed when compared with those with two replannings. The total maximum doses to the optic chiasm and pituitary gland and the mean doses to the left and right parotid glands were increased by 10.50 {+-} 10.51%, 8.59 {+-} 6.10%, 3.03 {+-} 4.48%, and 2.24 {+-} 3.11%, respectively (P = 0.014, 0.003, 0.053, and 0.046, respectively). The 3-phase radiotherapy protocol showed improved dosimetric results to the critical structures while keeping satisfactory target dose coverage, which demonstrated the advantages of ART in helical tomotherapy of NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗

On the use of volumetric-modulated arc therapy for single-fraction thoracic vertebral metastases stereotactic body radiosurgery

To retrospectively evaluate quality, efficiency, and delivery accuracy of volumetric-modulated arc therapy (VMAT) plans for single-fraction treatment of thoracic vertebral metastases using image-guided stereotactic body radiosurgery (SBRS) after RTOG 0631 dosimetric compliance criteria. After obtaining credentialing for MD Anderson spine phantom irradiation validation, 10 previously treated patients with thoracic vertebral metastases with noncoplanar hybrid arcs using 1 to 2 3D-conformal partial arcs plus 7 to 9 intensity-modulated radiation therapy beams were retrospectively re-optimized with VMAT using 3 full coplanar arcs. Tumors were located between T2 and T12. Contrast-enhanced T1/T2-weighted magnetic resonance images were coregistered with planning computed tomography and planning target volumes (PTV) were between 14.4 and 230.1 cc (median = 38.0 cc). Prescription dose was 16 Gy in 1 fraction with 6 MV beams at Novalis-TX linear accelerator consisting of micro multileaf collimators. Each plan was assessed for target coverage using conformality index, the conformation number, the ratio of the volume receiving 50% of the prescription dose over PTV, R50%, homogeneity index (HI), and PTV-1600 coverage per RTOG 0631 requirements. Organs-at-risk doses were evaluated for maximum doses to spinal cord (D{sub 0.03} {sub cc}, D{sub 0.35} {sub cc}), partial spinal cord (D{sub 10%}), esophagus (D{sub 0.03} {sub cc} and D{sub 5} {sub cc}), heart (D{sub 0.03} {sub cc} and D{sub 15} {sub cc}), and lung (V{sub 5}, V{sub 10}, and maximum dose to 1000 cc of lung). Dose delivery efficiency and accuracy of each VMAT-SBRS plan were assessed using quality assurance (QA) plan on MapCHECK device. Total beam-on time was recorded during QA procedure, and a clinical gamma index (2%/2 mm and 3%/3 mm) was used to compare agreement between planned and measured doses. All 10 VMAT-SBRS plans met RTOG 0631 dosimetric requirements for PTV coverage. The plans demonstrated highly conformal and homogenous coverage of the vertebral PTV with mean HI, conformality index, conformation number, and R{sub 50%} values of 0.13 ± 0.03 (range: 0.09 to 0.18), 1.03 ± 0.04 (range: 0.98 to 1.09), 0.81 ± 0.06 (range: 0.72 to 0.89), and 4.2 ± 0.94 (range: 2.7 to 5.4), respectively. All 10 patients met protocol guidelines with maximum dose to spinal cord (average: 8.83 ± 1.9 Gy, range: 5.9 to 10.9 Gy); dose to 0.35 cc of spinal cord (average: 7.62 ± 1.7 Gy, range: 5.4 to 9.6 Gy); and dose to 10% of partial spinal cord (average 6.31 ± 1.5 Gy, range: 3.5 to 8.5 Gy) less than 14, 10, and 10 Gy, respectively. For all 10 patients, the maximum dose to esophagus (average: 9.41 ± 4.3 Gy, range: 1.5 to 14.9 Gy) and dose to 5 cc of esophagus (average: 7.43 ± 3.8 Gy, range: 1.1 to 11.8 Gy) were kept less than protocol requirements 16 Gy and 11.9 Gy, respectively. In a similar manner, all 10 patients met protocol compliance criteria with maximum dose to heart (average: 4.62 ± 3.5 Gy, range: 1.3 to 10.2 Gy) and dose to 15 cc of heart (average: 2.23 ± 1.8 Gy, range: 0.3 to 5.6 Gy) less than 22 and 16 Gy, respectively. The dose to the lung was retained much lower than protocol guidelines for all 10 patients. The total number of monitor units was, on average, 6919 ± 1187. The average beam-on time was 11.5 ± 2.0 minutes. The VMAT plans demonstrated dose delivery accuracy of 95.8 ± 0.7%, on average, for clinical gamma passing rate with 2%/2 mm criteria and 98.3 ± 0.8%, on average, with 3%/3 mm criteria. All VMAT-SBRS plans were considered clinically acceptable per RTOG 0631 dosimetric compliance criteria. VMAT planning provided highly conformal and homogenous dose distributions for the lower-dose vertebral PTV and the spinal cord as well as organs-at-risk such as esophagus, heart, and lung. Higher QA pass rates and shorter beam-on time suggest that VMAT-SBRS is a clinically feasible, fast, and effective treatment option for patients with thoracic vertebral metastases.

61 RADIATION PROTECTION AND DOSIMETRY↗

Immobilization and image-guidance methods for radiation therapy of limb extremity soft tissue sarcomas: Results of a multi-institutional survey

Radiation therapy for limb-extremity soft tissue sarcoma (STS) requires accurate, reproducible dose delivery. However, patient positioning is challenging and there is a lack of existing guidelines to assist institutional standardization. Therefore, we conducted a multi-institutional international survey of STS immobilization, image guidance methods, and treatment protocols to investigate current practice. Seventy-three UK radiotherapy centers and 15 hospitals in 7 other countries completed a questionnaire on STS immobilization and image-guidance procedures. Specifically, the survey collated information on the current usage of immobilization equipment, including custom devices, patient setup tolerances, the use of written protocols, the modality and frequency of image guidance, the method of treatment, allocated treatment times, and the application of surgical clips. Multiple combinations of immobilization devices were reported. In the UK, 12%, 40%, 30%, 12%, and 5% use 1, 2, 3, 4, and 5 types of device for lower limb STS. Vacuum bag plus either foot or ankle support was most common (66%). Of 15 international centers, 27%, 60%, 7%, 0%, 7% use 1, 2, 3, 4, 5 devices, with vacuum bags (73%) and thermoplastic (47%) predominant, similar to UK values of 77% and 52%. For image guidance, in the UK, 37% use kV planar, 34% use MV planar, and 16% use cone-beam CT for the first 3 fractions and then weekly. Internationally, daily imaging was more prevalent with 33% using kV planar, 7% MV planar, and 40% cone-beam CT daily. Custom devices plus combinations of devices, along with 5- and 10-mm set-up tolerances, were most commonly reported. Less than half of centers have written treatment protocols. Conventional treatment is most common in the UK, with only 42% using conformal techniques. Treatment is allocated between 10 and 30 minutes. Twenty-six percent of UK centers and 53% of international centers use surgical clips. Across treatment centers, there is no consistent approach to STS immobilization, image-guidance methods, or treatment protocols assessed by this survey. A wide variety of immobilization devices and configurations are utilized, and the frequency and modality of imaging are similarly diverse. In the absence of guidelines, the creation of an online repository of example immobilization techniques could enable centers to compare a diversity of cases. The availability of a forum for viewing and discussing a range of cases could potentially lead to improved patient setup and reduce the time taken to devise an individual immobilization strategy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Size effects of latex nanomaterials on lung inflammation in mice

Effects of nano-sized materials (nanomaterials) on sensitive population have not been well elucidated. This study examined the effects of pulmonary exposure to (latex) nanomaterials on lung inflammation related to lipopolysaccharide (LPS) or allergen in mice, especially in terms of their size-dependency. In protocol 1, ICR male mice were divided into 8 experimental groups that intratracheally received a single exposure to vehicle, latex nanomaterials (250 {mu}g/animal) with three sizes (25, 50, and 100 nm), LPS (75 {mu}g/animal), or LPS plus latex nanomaterials. In protocol 2, ICR male mice were divided into 8 experimental groups that intratracheally received repeated exposure to vehicle, latex nanomaterials (100 {mu}g/animal), allergen (ovalbumin: OVA; 1 {mu}g/animal), or allergen plus latex nanomaterials. In protocol 1, latex nanomaterials with all sizes exacerbated lung inflammation elicited by LPS, showing an overall trend of amplified lung expressions of proinflammatory cytokines. Furthermore, LPS plus nanomaterials, especially with size less than 50 nm, significantly elevated circulatory levels of fibrinogen, macrophage chemoattractant protein-1, and keratinocyte-derived chemoattractant, and von Willebrand factor as compared with LPS alone. The enhancement tended overall to be greater with the smaller nanomaterials than with the larger ones. In protocol 2, latex nanomaterials with all sizes did not significantly enhance the pathophysiology of allergic asthma, characterized by eosinophilic lung inflammation and Igs production, although latex nanomaterials with less than 50 nm significantly induced/enhanced neutrophilic lung inflammation. These results suggest that latex nanomaterials differentially affect two types of (innate and adaptive immunity-dominant) lung inflammation.

60 APPLIED LIFE SCIENCES↗

Platoon management with cooperative adaptive cruise control enabled by VANET

Previous studies have shown the ability of vehicle platooning to improve highway safety and throughput. With Vehicular Ad-hoc Network (VANET) and Cooperative Adaptive Cruise Control (CACC) system, vehicle platooning with small headway becomes feasible. In this paper, we developed a platoon management protocol for CACC vehicles based on wireless communication through VANET. This protocol includes three basic platooning maneuvers and a set of micro-commands to accomplish these maneuvers. Various platooning operations such as vehicle entry and vehicle (including platoon leader) leaving can be captured by these basic platoon maneuvers. The protocol operation is described in detail using various Finite State Machines (FSM), and can be applied in collaborative driving and intelligent highway systems. This protocol is determined in an integrated simulation platform, VENTOS, which is developed based on SUMO and OMNET++. The validity and effectiveness of our approach is shown by means of simulations, and different platooning setting are calibrated.

42 ENGINEERING↗

Simple Sodium Dodecyl Sulfate-Assisted Sample Preparation Method for LC-MS-based Proteomic Applications

Sodium dodecyl sulfate (SDS) is one of the most popular laboratory reagents used for highly efficient biological sample extraction; however, SDS presents a significant challenge to LC-MS-based proteomic analyses due to its severe interference with reversed-phase LC separations and electrospray ionization interfaces. This study reports a simple SDS-assisted proteomic sample preparation method facilitated by a novel peptide-level SDS removal protocol. After SDS-assisted protein extraction and digestion, SDS was effectively (>99.9%) removed from peptides through ion substitution-mediated DS- precipitation with potassium chloride (KCl) followed by {approx}10 min centrifugation. Excellent peptide recovery (>95%) was observed for less than 20 {mu}g of peptides. Further experiments demonstrated the compatibility of this protocol with LC-MS/MS analyses. The resulting proteome coverage from this SDS-assisted protocol was comparable to or better than those obtained from other standard proteomic preparation methods in both mammalian tissues and bacterial samples. These results suggest that this SDS-assisted protocol is a practical, simple, and broadly applicable proteomic sample processing method, which can be particularly useful when dealing with samples difficult to solubilize by other methods.

59 BASIC BIOLOGICAL SCIENCES↗

Impacts of Solvent Washing on the Electrochemical Remediation of Commercial End-of-Life Cathodes

Changes to surface structure and chemistry occurring throughout the functional lifetime of lithium-ion batteries (LIBs) may impact the effectiveness of end-of-life rejuvenation methods. Solvent washing prior to electrochemical relithiation is shown to both increase relithiation efficacy and beneficially alter the interfacial chemistry of heavily degraded industrial cathode material. Four common solvents (acetone, diethyl carbonate, isopropyl alcohol, propylene carbonate) are employed to investigate the role of varying physicochemical solvent properties on the mechanism of capacity recovery. Electrochemical (dQ/dV, EIS), structural (XRD), and chemical (SPME-GC-MS) analysis techniques are employed to comprehensively analyze solvent-cathode interactions. Highly nucleophilic solvents (acetone, DEC) are found to reduce cathode charge-transfer impedance and enable stable impedance growth throughout subsequent cycling. The use of nucleophilic solvents under mechanically aggressive washing conditions may also enable the reintroduction of bulk lattice oxygen, thereby restoring anionic redox capacity. Further, the four solvents are found to selectively remove a subset of surface species from the aged cathode material, including residual electrolyte, additives, and electrolyte-additive reaction products, which are qualitatively analyzed. Surface species removal by each solvent is correlated with the electrochemical performance of the correspondingly washed cathode, highlighting the importance of an optimized washing protocol to effective remediation in the context of direct LIB recycling. For the material under study, the use of a simple acetone washing protocol prior to electrochemical relithiation enables up to 174% capacity recovery relative to unwashed/relithiated black mass.

ADVANCED PROPULSION SYSTEMS↗

Effect of Water Vapor, Temperature, and Rapid Annealing on Formamidinium Lead Triiodide Perovskite Crystallization

Perovskite-based solar cells are one of the emerging candidates for radically lower cost photovoltaics. Herein, we report on the synthesis and crystallization of organic-inorganic formamidinium lead triiodide perovskite films under controlled atmospheric and environmental conditions. Using in situ (scanning) transmission electron microscopy, we make observations of the crystallization process of these materials in nitrogen and oxygen gas with and without the presence of water vapor. Complementary planar samples were also fabricated in the presence of water vapor and characterized by in situ X-ray diffraction. Direct observations of the material structure and final morphology indicate that the exposure to water vapor results in a porous film that is metastable, regardless of the presence of argon, nitrogen, or oxygen. However, the optimal crystallization temperature of 175 °C is unperturbed across conditions. Rapid modulation about the annealing temperature of 175 °C in ±25 °C steps (150-200 °C) promotes crystallization and significantly improves the film morphology by overcoming the presence of impregnated water trapped in the material. Following this processing protocol, we demonstrate substantial growth to micron-size grains via observation inside of an environmentally controlled transmission electron microscope. Adapting this insight from our in situ microscopy, we are able to provide an informed materials protocol to control the structure and morphology of these organic-inorganic semiconductors, which is readily applicable to benchtop device growth strategies.

36 MATERIALS SCIENCE↗

Determination of Phase Diagrams for Soluble and Membrane Protein Systems

Methods to efficiently determine the phase behavior of novel proteins have the potential to significantly benefit structural biology efforts. Here, we present protocols to determine both the solubility boundary and the supersolubility boundary for protein/precipitant systems using an evaporation-based crystallization platform. This strategy takes advantage of the well-defined rates of evaporation that occur in this platform to determine the state of the droplet at any point in time without relying on an equilibrium-based end point. The dynamic nature of this method efficiently traverses phase space along a known path, such that a solubility diagram can be mapped out for both soluble and membrane proteins while using a smaller amount of protein than what is typically used in optimization screens. Furthermore, a variation on this method can be used to decouple crystal nucleation and growth events, so fewer and larger crystals can be obtained within a given droplet. The latter protocol can be used to rescue a crystallization trial where showers of tiny crystals were observed. We validated both of the protocols to determine the phase behavior and the protocol to optimize crystal quality using the soluble proteins lysozyme and ribonuclease A as well as the membrane protein bacteriorhodopsin.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗