Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample collection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Ranking Biological Features in Soil-Based Microbial Multi-Omics Data with Integration Modeling

Distinguishing the most important features (e.g. proteins, metabolites, etc.) per group (e.g. control and treatment) is a critical challenge in feature-rich multi-omics experiments, especially in soil data. Traditional feature identification and ranking approaches, such as differential expression, are based on single omics and thus not directly translatable to multi-omics experiments. Here, 5 multi-omics integration models (DIABLO, JACA, MOFA, MultiMLP, and SLIDE) that were not explicitly built for soil data applications were tested using a soil-based multi-omics experiment. The data were obtained from an experimental setup of an autoclaved soil system inoculated with 8 bacteria and using chitin as the carbon source and including samples collected at 0- (control), 4-, 8-, and 12-weeks post-inoculation. The omics data included metaproteomics, 16S rRNA sequencing, and LC-MS/MS metabolomics (in positive and negative mode). Each multi-omics integration model was implemented, and top features were compared to differential univariate statistics per omic type, demonstrating that integration approaches cut the potential number of top features from 2957 identified by differential statistics to 13-224 (a 99.6% to 92.4% reduction). Interestingly, most top features across integration models were not shared; though, scaling and averaging ranks across models shared similar patterns. This work highlights the usefulness of multi-omics integration models in soil-based microbial studies and the power of using multiple integration models together to interpret results.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Organosulfates and Organonitrates in Vertically Resolved Aerosols over the Southern Great Plains Field Campaign Report

Aerosol is the largest individual source of uncertainty in assessing the Earth’s radiative balance due to poorly understood aerosol processes and aerosol-cloud interactions. Thus, to constrain aerosol’s climate impacts, it is critical to understand aerosol compositions at high elevations. Organic material accounts for about 20-80% of total aerosol mass in the atmosphere and is known to play a key role in aerosol processes and cloud formation. In prior research, characterization of aerosol molecular composition has been mostly carried out at ground level. In these ground-level measurements, total speciated organosulfates and organonitrates may contribute significantly to organic aerosol mass on the order of 10-40%, most of which are from abundant biogenic volatile organic compounds such as isoprene and monoterpenes. Organosulfates and organonitrates have also been shown to be present in substantial amounts in cloud water, suggesting that they can be transported and/or directly formed at high elevations. On the other hand, the less common and more expensive aircraft studies have performed high-altitude measurements, but were often limited in the number of different altitudes sampled and in sample collection under consistent conditions. Therefore, the vertical distributions of key aerosol components such as organosulfates and organonitrates are not well understood and have not been extensively studied. Nevertheless, it is important to understand how organosulfates and organonitrates in aerosols are distributed, transformed, participate in aqueous-phase processes, and interact with high-altitude clouds.

54 ENVIRONMENTAL SCIENCES↗

Filtration Performance of Simulated 200 West Area Waste Feeds

This report describes the scaled experimental system and approach used to examine dead-end filtration performance of representative 200W waste feeds. The scaled system, which was originally designed and assembled to test Tank Side Cesium Removal (TSCR) system performance with higher-than-expected solid loadings in 2021 (Schonewill et al. 2021), was repurposed to conduct the current experiments at ~1/145 of full scale (based on throughput). Six experimental runs were conducted with five different 200W waste feed simulants: three using a DEF module scaled for TSCR and three using a DEF module scaled for the 200W process modules (based on the current design for the Advanced Modular Pretreatment System). Each experiment was run continuously for multiple days with an operating approach prototypic of the full-scale system. Staff performing the experimental runs monitored performance, obtained data from calibrated process instruments, and collected samples for observation and analysis. The measured data are presented with a focus on assessing DEF performance – specifically, the filters’ differential pressure response to the five waste simulants, frequency and efficacy of backwashing, and baseline recovery between experimental runs; data related to ion exchange column performance are also discussed in cases where the opportunity arose. The experimental campaign demonstrated that the DEFs satisfied their primary function of protecting the ion exchange column from solid intrusion for all the representative simulants used. The filters readily handled solids loadings of =500 ppm (and even greater), especially the modules scaled to the 200W process modules. Adjustments to the processing flow rate and reductions in feed temperature were observed to affect the rate of differential pressure increase on the filters, but neither adversely affected the ability of the DEFs to perform their primary function. Backflushing reliably recovered filter performance in all runs, although it did not prevent irreversible fouling for one simulant. The run that exhibited irreversible fouling established that both the quantity and the nature of the solids being filtered need to be considered when projecting filter performance.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final report : results of the 2006 investigation of potential contamination at the former CCC/USDA facility in Ramona, Kansas.

The investigation reported here was conducted by the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) in 2006. The investigation addressed carbon tetrachloride contamination on the former CCC/USDA grain storage facility at Ramona, Kansas. The results clearly demonstrate that only minimal contamination is associated with the past use of carbon tetrachloride on the former CCC/USDA property. No soil contamination was detected at concentrations above Kansas Department of Health and Environment (KDHE) risk-based screening level (RBSL) Tier 2 standard of 200 {micro}g/kg for the soil-to-groundwater protection pathway. Carbon tetrachloride concentrations in groundwater above the RBSL and maximum contaminant level (MCL) value of 5.0 {micro}g/L were detected in only two samples, collected at adjacent locations on the southeast part of the property. The relatively low concentrations detected and the limited areal extent of the contamination demonstrate that no imminent threat exists on the former CCC/USDA property to warrant remediation. The soil and groundwater contamination detected on the former CCC/USDA property is clearly separate from contamination detected at off-site locations. The carbon tetrachloride and chloroform contamination in groundwater (at concentrations above the RBSL and MCL value) associated with past activities on the former CCC/USDA property is contained within the property boundaries. Data collected independently by the KDHE in 2006 validate these findings and, furthermore, provide additional evidence that the sources identified on the Co-op property (west of the former CCC/USDA property) are separate from the comparatively minor results of past activities on the former CCC/USDA property. The KDHE concluded in its 2006 report that the sources are separate and that the Co-op is the principally responsible party for the carbon tetrachloride contamination detected during its 2006 investigation.

54 ENVIRONMENTAL SCIENCES↗

Investigation of contaminant sources at Navarre, Kansas.

The results of the 2006 investigation of contaminant sources at Navarre, Kansas, clearly demonstrate the following: {sm_bullet} Sources of carbon tetrachloride contamination were found on the Navarre Co-op property. These sources are the locations of the highest concentrations of carbon tetrachloride found in soil and groundwater at Navarre. The ongoing groundwater contamination at Navarre originates from these sources. {sm_bullet} The sources on the Co-op property are in locations where the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) never conducted grain storage operations. {sm_bullet} No definitive sources of carbon tetrachloride were identified on the portion of the current Co-op property formerly used by the CCC/USDA. {sm_bullet} The source areas on the Co-op property are consistent with the locations of the most intense Co-op operations, both historically and at present. The Co-op historically stored carbon tetrachloride for retail sale and used it as a grain fumigant in these locations. {sm_bullet} The distribution patterns of other contaminants (tetrachloroethene and nitrate) originating from sources on the Co-op property mimic the carbon tetrachloride plume. These other contaminants are not associated with CCC/USDA operations. {sm_bullet} The distribution of carbon tetrachloride at the Co-op source areas, particularly the absence of contamination in soils at depths less than 20 ft below ground level, is consistent with vertical migration into the subsurface through a conduit (well Co-op 2), with subsequent lateral migration through the subsurface. {sm_bullet} The groundwater flow direction, which is toward the west-northwest, is not consistent with migration of carbon tetrachloride in groundwater from the former CCC/USDA property to the source areas on the Co-op property. {sm_bullet} The absence of soil and groundwater contamination along surface drainage pathways on the former CCC/USDA property is not consistent with migration of carbon tetrachloride in surface water runoff from the former CCC/USDA property to the source areas on the Co-op property. {sm_bullet} The contamination detected in soil and groundwater samples collected along the northern boundary of the former CCC/USDA facility can be attributed to migration from the Co-op sources or to operations of the Co-op on the property after CCC/USDA operations ended. {sm_bullet} The southern boundary of the Co-op property has expanded over time, so that the Co-op has operated for a lengthy period in all areas previously leased by the CCC/USDA (Figure S.1). The Co-op began expanding onto the former CCC/USDA property in 1969 and has operated on that property longer than the CCC/USDA did. The use of carbon tetrachloride as a grain fumigant was standard industry practice until 1985, when the compound was banned by the U.S. Environmental Protection Agency. {sm_bullet} Petroleum-related contamination was detected on the southern part of the former CCC/USDA property. This contamination is associated with aboveground storage tanks that are owned and operated by the Co-op. The major findings of the 2006 investigations are summarized in greater detail below. The 2006 investigation was implemented by the Environmental Science Division of Argonne National Laboratory on behalf of the CCC/USDA.

54 ENVIRONMENTAL SCIENCES↗

Top quark mass measurement

The top quark is the heaviest elementary particle. Its mass is one of the fundamental parameters of the standard model of particle physics, and an important input to precision electroweak tests. This thesis describes three measurements of the top-quark mass in the dilepton decay channel. The dilepton events have two neutrinos in the final state; neutrinos are weakly interacting particles that cannot be detected with a multipurpose experiment. Therefore, the signal of dilepton events consists of a large amount of missing energy and momentum carried off by the neutrinos. The top-quark mass is reconstructed for each event by assuming an additional constraint from a top mass independent distribution. Template distributions are constructed from simulated samples of signal and background events, and parametrized to form continuous probability density functions. The final top-quark mass is derived using a likelihood fit to compare the reconstructed top mass distribution from data to the parametrized templates. One of the analyses uses a novel technique to add top mass information from the observed number of events by including a cross-section-constraint in the likelihood function. All measurements use data samples collected by the CDF II detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Completion Report for the Well ER-6-2 Site Corrective Action Unit 97: Yucca Flat - Climax Mine

Well ER-6-2 and its satellite hole, Well ER-6-2 No.1, were drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office in support of the Nevada Environmental Restoration Project at the Nevada Test Site, Nye County, Nevada. Well ER-6-2 was drilled in two stages in 1993 and 1994; the satellite hole, Well ER-6-2 No.1 was drilled nearby in 1993 but was abandoned. The wells were drilled as part of a hydrogeologic investigation program for the Yucca Flat-Climax Mine Corrective Action Unit Number 97, in the northeastern portion of the Nevada Test Site. The wells are located in Yucca Flat, within Area 6 of the Nevada Test Site. The wells provided information regarding the radiological and hydrogeological environment in a potentially down-gradient position from tests conducted in northern and central Yucca Flat. Construction of Well ER-6-2 began with a 1.2-meter-diameter surface conductor hole, which was drilled and cased off to a depth of 30.8 meters below the surface. A 50.8-centimeter diameter surface hole was then rotary drilled to the depth of 578.5 meters and cased off to the depth of 530.4 meters. The hole diameter was then reduced to 27.0 centimeters, and the borehole was advanced to a temporary depth of 611.4 meters. The borehole was conventionally cored to a total depth of 1,045 meters with a diameter of 14.0 centimeters. Borehole sloughing required cementing and re-drilling of several zones. The open-hole completion accesses the lower carbonate aquifer, the CP thrust fault, and the upper clastic confining unit. A fluid level depth of 543.2 meters was most recently measured in the open borehole in September 2007. No radionuclides were encountered during drilling. The satellite hole Well ER-6-2 No.1 was drilled approximately 15.2 meters north of Well ER-6-2 on the same drill pad. This was planned to be used as an observation well during future hydrologic testing at Well ER-6-2; however, the satellite hole was abandoned at the depth of 399 meters due to stuck drill pipe, and was subsequently cemented to the surface. Detailed lithologic descriptions with stratigraphic assignments in this report are based on composite drill cuttings samples collected every 3 meters, cores taken between the depths of 619.3 and 1,042.4 meters, and geophysical log data. Stratigraphic assignments within the Paleozoic section are based on paleontological analyses. The well was collared in alluvium and at 30.8 meters penetrated Paleozoic carbonate rocks. These consisted of dolostone with minor shale and limestone of the Bonanza King Formation, and limestone with minor quartzite, sandstone, and dolostone assigned to the Guilmette Formation. The borehole reached total depth in a shale unit assigned to the Chainman Shale. The units below the Bonanza King Formation are overturned due to faulting and folding and, therefore, are stratigraphically upside-down.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surveillance of site A and plot M, report for 2007.

The results of the environmental surveillance program conducted at Site A/Plot M in the Palos Forest Preserve area for Calendar Year 2007 are presented. Based on the results of the 1976-1978 radiological characterization of the site, a determination was made that a surveillance program be established. The characterization study determined that very low levels of hydrogen-3 (as tritiated water) had migrated from the burial ground and were present in two nearby hand pumped picnic wells. The current surveillance program began in 1980 and consists of sample collection and analysis of surface and subsurface water. The results of the analyses are used to: (1) monitor the migration pathway of water from the burial ground (Plot M) to the hand-pumped picnic wells, (2) establish if other buried radionuclides have migrated, and (3) monitor the presence of radioactive materials in the environment of the area. Hydrogen-3 in the Red Gate Woods picnic wells was still detected this year, but the average and maximum concentrations were significantly less than found earlier. Hydrogen-3 continues to be detected in a number of wells, boreholes, dolomite holes, and a surface stream. Analyses since 1984 have indicated the presence of low levels of strontium-90 in water from a number of boreholes next to Plot M. The results of the surveillance program continue to indicate that the radioactivity remaining at Site A/Plot M does not endanger the health or safety of the public visiting the site, using the picnic area, or living in the vicinity.

54 ENVIRONMENTAL SCIENCES↗

TESTING OF A ROTARY MICROFILTER TO SUPPORT HANFORD APPLICATIONS

Savannah River National Laboratory (SRNL) researchers are investigating and developing a rotary microfilter for solid-liquid separation applications at the Savannah River Site (SRS). Because of the success of that work, the Hanford Site is evaluating the use of the rotary microfilter for its Supplemental Pretreatment process. The authors performed rotary filter testing with a full-scale, 25-disk unit with 0.5 {micro} filter media manufactured by Pall Corporation using a Hanford AN-105 simulant at solids loadings of 0.06, 0.29, and 1.29 wt%. The conclusions from this testing are: (1) The filter flux at 0.06 wt% solids reached a near constant value at an average of 0.26 gpm/ft{sup 2} (6.25 gpm total). (2) The filter flux at 0.29 wt% solids reached a near constant value at an average of 0.17 gpm/ft{sup 2} (4 gpm total). (3) The filter flux at 1.29 wt% solids reached a near constant value at an average of 0.10 gpm/ft{sup 2} (2.4 gpm total). (4) Because of differences in solids loadings, a direct comparison between crossflow filter flux and rotary filter flux is not possible. The data show the rotary filter produces a higher flux than the crossflow filter, but the improvement is not as large as seen in previous testing. (5) Filtrate turbidity measured < 4 NTU in all samples collected. (6) During production, the filter should be rinsed with filtrate or dilute caustic and drained prior to an extended shutdown to prevent the formation of a layer of settled solids on top of the filter disks. (7) Inspection of the seal faces after {approx} 140 hours of operation showed an expected amount of initial wear, no passing of process fluid through the seal faces, and very little change in the air channeling grooves on the stationary face. (8) Some polishing was observed at the bottom of the shaft bushing. The authors recommend improving the shaft bushing by holding it in place with a locking ring and incorporated grooves to provide additional cooling. (9) The authors recommend that CH2MHill Hanford test other pore size media to determine the optimum pore size for Hanford waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Volatile Organic Compound Investigation Results, 300 Area, Hanford Site, Washington

Unexpectedly high concentrations of volatile organic compounds (VOC) were discovered while drilling in the unconfined aquifer beneath the Hanford Site’s 300 Area during 2006. The discovery involved an interval of relatively finer-grained sediment within the unconfined aquifer, an interval that is not sampled by routine groundwater monitoring. Although VOC contamination in the unconfined aquifer has been identified and monitored, the concentrations of newly discovered contamination are much higher than encountered previously, with some new results significantly higher than the drinking water standards. The primary contaminant is trichloroethene, with lesser amounts of tetrachloroethene. Both chemicals were used extensively as degreasing agents during the fuels fabrication process. A biological degradation product of these chemicals, 1,2-dichloroethene, was also detected. To further define the nature and extent of this contamination, additional characterization drilling was undertaken during 2007. Four locations were drilled to supplement the information obtained at four locations drilled during the earlier investigation in 2006. The results of the combined drilling indicate that the newly discovered contamination is limited to a relatively finer-grained interval of Ringold Formation sediment within the unconfined aquifer. The extent of this contamination appears to be the area immediately east and south of the former South Process Pond. Samples collected from the finer-grained sediment at locations along the shoreline confirm the presence of the contamination near the groundwater/river interface. Contamination was not detected in river water that flows over the area where the river channel potentially incises the finer-grained interval of aquifer sediment. The source for this contamination is not readily apparent. A search of historical documents and the Hanford Waste Information Data System did not provide definitive clues as to waste disposal operations and/or spills that might have resulted in groundwater contamination in this sediment, although several relatively small accidental releases of VOCs have occurred in the past in the northern portion of the 300 Area. It is likely that large quantities of degreasing solutions were disposed to the North and South Process Ponds during the 1950s and 1960s, and that evidence for them in the upper portion of the unconfined aquifer has been removed because of groundwater movement through the much more transmissive sediment. Also, investigations to date have revealed no evidence to suggest that a dense, non-aqueous phase liquid remains undetected in the subsurface. Potential pathways for contamination to migrate from this finer-grained sediment include groundwater movement through the interval to offshore locations in the Columbia River channel, dispersion out of the finer-grained interval into the overlying transmissive sediment (again, with transport to the riverbed), and potential future withdrawal via water supply wells.

300 Area↗

Characterization of Vadose Zone Sediments from C Waste Management Area: Investigation of the C-152 Transfer Line Leak

The sodium data was removed due to potential contamination introduced during the acid extraction process. The rest of the text remains unchanged from the original report issued in January 2007. The overall goal of the Tank Farm Vadose Zone Project, led by CH2M HILL Hanford Group, Inc., is to define risks from past and future single-shell tank farm activities at Hanford. To meet this goal, CH2M HILL Hanford Group, Inc., tasked scientists from Pacific Northwest National Laboratory to perform detailed analyses on vadose zone sediments from within waste management area (WMA) C. Specifically, this report contains all the geologic, geochemical, and selected physiochemical characterization data compiled on vadose zone sediment recovered from direct-push samples collected around the site of an unplanned release (UPR), UPR-200-E-82, adjacent to the 241-C-152 Diversion Box located in WMA C.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of Accelerated Casing Corrosion in Two Wells at Waste Management Area A-AX

This report was revised in September 2008 to remove acid-extractable sodium data from Tables 3.13 and 3.14. The sodium data was removed due to potential contamination introduced during the acid extraction process. The rest of the text remains unchanged from the original report issued in August 2005. An overall goal of the Groundwater Performance Assessment Project, led by Pacific Northwest National Laboratory (PNNL) and per guidance in DOE Order 5400.1, includes characterizing and defining trends in the physical, chemical, and biological condition of the environment. To meet these goals, numerous Resource Conservation and Recovery Act (RCRA) monitoring wells have been installed throughout the Hanford Site. In 2003, it was determined that two RCRA monitoring wells (299-E24-19 and 299-E25-46) in Waste Management Area (WMA) A-AX failed due to rapid corrosion of the stainless steel casing over a significant length of the wells. Complete casing corrosion occurred between 276.6 and 277.7 feet below ground surface (bgs) in well 299- E24-19 and from 274.4 to 278.6 feet bgs in well 299-E25-46. CH2M HILL Hanford Group, Inc., asked scientists from PNNL to perform detailed analyses of vadose zone sediment samples collected in the vicinity of the WMA A-AX from depths comparable to those where the rapid corrosion occurred in hopes of ascertaining the cause of the rapid corrosion.

36 MATERIALS SCIENCE↗

Search for CP violation in B 0 s to JΨΦ

The CDF experiment, which uses p$\bar{p}$ collisions at √s = 1.9 TeV produced at the Fermilab Tevatron, is unique in its ability to observe all flavors of B hadrons and measure their properties. Among them, CP violation is of fundamental interest. In the B + and B 0 systems, measurements of CP violation parameters performed essentially at B factories have borne out the predictions of CKM model. Little is known, experimentally, about CP violation in the B s 0 system. The standard model predicts very little CP violation there, thus any nonzero measurement could be an indication of new physics. In this thesis, we will report on the very first flavor-tagged analysis of approximately 2000 B s 0 → J/ΨΦ decays reconstructed in a 1.35 fb -1 data sample collected at CDF. This channel is sensitive not only to the width difference ΔΓ in the B{sub s}{sup 0} system but also to the CP violation parameter β s . The final result we obtain is a confidence region in the two dimensional space of β s and ΔΓ. Assuming the standard model predictions of β s and ΔΓ, the probability is 15%, corresponding to 1.5 Gaussian standard deviations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of CP violation in B 0 s → J/ΨΦ decays at D0

In a universe dominated by matter, the source of CP violation may explain one of the greatest mysteries in particle physics: what happened to the antimatter? The Standard Model successfully describes CP violation in the B + and B d 0 systems, yet insufficiently accounts for the observed matter-antimatter asymmetry. The Standard Model predicts a small value of CP violation in the B s 0 meson system, which has only recently been experimentally tested. A measurement of large, anomalous CP violation in the B s 0 system would be a clear indication of new physics sources beyond the Standard Model. This dissertation describes a study of CP violation in approximately 2000 B s 0 → J/ΨΦ decays reconstructed in a 2.8 fb -1 data sample collected by the D0 Run II detector at Fermi National Accelerator Laboratory in Batavia, Illinois. This data was provided by p$\bar{p}$ collisions at √s = 1.96 TeV delivered by the Tevatron accelerator between April 2002 and August 2007. Flavor-tagged B s 0 → J/Ψ(μ + μ - )Φ(K + K - ) decays and an angular analysis are used to study the time evolution of the final state angular distributions. From this analysis, we measure the width difference between the heavy and light mass eigenstates, B s L and B s H , to be ΔΓ s = 0.19 ± 0.07 and the CP-violating phase Φ s = -0.57 -0.30 +0.24 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Surveillance of Site A and Plot M, Report for 2008.

The results of the environmental surveillance program conducted at Site A/Plot M in the Palos Forest Preserve area for Calendar Year 2008 are presented. Based on the results of the 1976-1978 radiological characterization of the site, a determination was made that a surveillance program be established. The characterization study determined that very low levels of hydrogen-3 (as tritiated water) had migrated from the burial ground and were present in two nearby hand pumped picnic wells. The current surveillance program began in 1980 and consists of sample collection and analysis of surface and subsurface water. The results of the analyses are used to (1) monitor the migration pathway of hydrogen-3 contaminated water from the burial ground (Plot M) to the hand-pumped picnic wells, (2) establish if other buried radionuclides have migrated, and (3) monitor for the presence of radioactive materials in the environment of the area. Hydrogen-3 in the Red Gate Woods picnic wells was still detected this year, but the average and maximum concentrations were significantly less than found earlier. Hydrogen-3 continues to be detected in a number of wells, boreholes, dolomite holes, and a surface stream. Analyses since 1984 have indicated the presence of low levels of strontium-90 in water from a number of boreholes next to Plot M. The results of the surveillance program continue to indicate that the radioactivity remaining at Site A/Plot M does not endanger the health or safety of the public visiting the site, using the picnic area, or living in the vicinity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measurement of the branching fraction Br (B 0 s → D s *D s * using the D0 detector at Fermilab

This thesis describes a measurement of the branching fraction Br (B 0 s → D s *D s *) made using a data sample collected from proton-antiproton collisions at a centre-of-mass energy of 1.96 TeV, corresponding to approximately 1.3 fb -1 of integrated luminosity collected in 2002--2006 by the D0 detector at the Fermilab Tevatron Collider. One D* s meson was partially reconstructed in the decay D s → Φμv, and the other D* s meson was identified using the decay D s → Φπ where no attempt was made to distinguish D s and D* s states. The resulting measurement is Br (B 0 s → D s *D s *) = 0.039 +0.019 -0.017 (stat) +0.016 -0.015 (syst). This was subsequently used to estimate the width difference ΔΓ CP s in the B 0 s -$\bar{B}$ 0 s system: ΔΓ CP s /Γ s = 0.079 +0.038 -0.035 (stat) +0.031 -0.030 (syst), and is currently one of the most precise estimates of this quantity and consistent with the Standard Model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ART CCIM Phase II-A Off-Gas System Evaluation Test Plan

This test plan defines testing to be performed using the Idaho National Laboratory (INL) engineering-scale cold crucible induction melter (CCIM) test system for Phase II-A of the Advanced Remediation Technologies (ART) CCIM Project. The multi-phase ART-CCIM Project is developing a conceptual design for replacing the joule-heated melter (JHM) used to treat high level waste (HLW) in the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS) with a cold crucible induction melter. The INL CCIM test system includes all feed, melter off-gas control, and process control subsystems needed for fully integrated operation and testing. Testing will include operation of the melter system while feeding a non-radioactive slurry mixture prepared to simulate the same type of waste feed presently being processed in the DWPF. Process monitoring and sample collection and analysis will be used to characterize the off-gas composition and properties, and to show the fate of feed constituents, to provide data that shows how the CCIM retrofit conceptual design can operate with the existing DWPF off-gas control system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Research, Monitoring, and Evaluation of Avian Predation on Salmonid Smolts in the Lower and Mid-Columbia River, 2008 Draft Season Summary.

This report describes investigations into predation by piscivorous colonial waterbirds on juvenile salmonids (Oncorhynchus spp.) from throughout the Columbia River basin during 2008. East Sand Island in the Columbia River estuary again supported the largest known breeding colony of Caspian terns (Hydroprogne caspia) in the world (approximately 10,700 breeding pairs) and the largest breeding colony of double-crested cormorants (Phalacrocorax auritus) in western North America (approximately 10,950 breeding pairs). The Caspian tern colony increased from 2007, but not significantly so, while the double-crested cormorant colony experienced a significant decline (20%) from 2007. Average cormorant nesting success in 2008, however, was down only slightly from 2007, suggesting that food supply during the 2008 nesting season was not the principal cause of the decline in cormorant colony size. Total consumption of juvenile salmonids by East Sand Island Caspian terns in 2008 was approximately 6.7 million smolts (95% c.i. = 5.8-7.5 million). Caspian terns nesting on East Sand Island continued to rely primarily on marine forage fishes as a food supply. Based on smolt PIT tag recoveries on the East Sand Island Caspian tern colony, predation rates were highest on steelhead in 2008; minimum predation rates on steelhead smolts detected passing Bonneville Dam averaged 8.3% for wild smolts and 10.7% for hatchery-raised smolts. In 2007, total smolt consumption by East Sand Island double-crested cormorants was about 9.2 million juvenile salmonids (95% c.i. = 4.4-14.0 million), similar to or greater than that of East Sand Island Caspian terns during that year (5.5 million juvenile salmonids; 95% c.i. = 4.8-6.2 million). The numbers of smolt PIT tags recovered on the cormorant colony in 2008 were roughly proportional to the relative availability of PIT-tagged salmonids released in the Basin, suggesting that cormorant predation on salmonid smolts in the estuary was less selective than tern predation. Cormorant predation rates in excess of 30%, however, were observed for some groups of hatchery-reared fall Chinook salmon released downstream of Bonneville Dam. Implementation of the federal plan 'Caspian Tern Management to Reduce Predation of Juvenile Salmonids in the Columbia River Estuary' was initiated in 2008 with construction by the Corps of Engineers of two alternative colony sites for Caspian terns in interior Oregon: a 1-acre island on Crump Lake in the Warner Valley and a 1-acre island on Fern Ridge Reservoir near Eugene. We deployed Caspian tern social attraction (decoys and sound systems) on these two islands and monitored for Caspian tern nesting. Caspian terns quickly colonized the Crump Lake tern island; about 430 pairs nested there, including 5 terns that had been banded at the East Sand Island colony in the Columbia River estuary, over 500 km to the northwest. No Caspian terns nested at the Fern Ridge tern island in 2008, but up to 9 Caspian terns were recorded roosting on the island after the nesting season. There were two breeding colonies of Caspian terns on the mid-Columbia River in 2008: (1) about 388 pairs nested at the historical colony on Crescent Island in the McNary Pool and (2) about 100 pairs nested at a relatively new colony site on Rock Island in the John Day Pool. Nesting success at the Crescent Island tern colony was only 0.28 young fledged per breeding pair, the lowest nesting success recorded at that colony since monitoring began in 2000, while only three fledglings were raised at the Rock Island tern colony. The diet of Crescent Island Caspian terns consisted of 68% salmonid smolts; total smolt consumption was estimated at 330,000. Since 2004, total smolt consumption by Crescent Island terns has declined by 34%, due mostly to a decline in colony size, while steelhead consumption has increased 10% during this same period. In 2008, approximately 64,000 steelhead smolts were consumed by Caspian terns nesting at Crescent Island. Based on smolt PIT tag recoveries on the Crescent Island Caspian tern colony, the average predation rate on in-river migrants from the Snake River (all species and run types combined based on interrogations at Lower Monumental Dam) was at least 1.4%. Predation rates on PIT-tagged steelhead smolts were greater than those for other salmonid species; 6.0% of wild steelhead smolts from the Snake River were consumed by Crescent Island terns. The double-crested cormorant colony on Foundation Island in the mid-Columbia River consisted of at least 360 pairs nesting in trees in 2008. The proportion of juvenile salmonids in stomach samples collected from cormorants nesting on Foundation Island during the peak of the smolt out-migration was about 45% of prey biomass.

13 HYDRO ENERGY↗