Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensitivity methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Group-equivariant autoencoder for identifying spontaneously broken symmetries

We introduce the group-equivariant autoencoder (GE autoencoder), a deep neural network (DNN) method that locates phase boundaries by determining which symmetries of the Hamiltonian have spontaneously broken at each temperature. We use group theory to deduce which symmetries of the system remain intact in all phases, and then use this information to constrain the parameters of the GE autoencoder such that the encoder learns an order parameter invariant to these “never-broken” symmetries. This procedure produces a dramatic reduction in the number of free parameters such that the GE-autoencoder size is independent of the system size. We include symmetry regularization terms in the loss function of the GE autoencoder so that the learned order parameter is also equivariant to the remaining symmetries of the system. By examining the group representation by which the learned order parameter transforms, we are then able to extract information about the associated spontaneous symmetry breaking. We test the GE autoencoder on the 2D classical ferromagnetic and antiferromagnetic Ising models, finding that the GE autoencoder (1) accurately determines which symmetries have spontaneously broken at each temperature; (2) estimates the critical temperature in the thermodynamic limit with greater accuracy, robustness, and time efficiency than a symmetry-agnostic baseline autoencoder; and (3) detects the presence of an external symmetry-breaking magnetic field with greater sensitivity than the baseline method. Lastly, we describe various key implementation details, including a quadratic-programming-based method for extracting the critical temperature estimate from trained autoencoders and calculations of the DNN initialization and learning rate settings required for fair model comparisons.

42 ENGINEERING↗

LOCALIZATION OF SHORT DURATION GRAVITATIONAL-WAVE TRANSIENTS WITH THE EARLY ADVANCED LIGO AND VIRGO DETECTORS

The Laser Interferometer Gravitational wave Observatory (LIGO) and Virgo advanced ground-based gravitational-wave detectors will begin collecting science data in 2015. With first detections expected to follow, it is important to quantify how well generic gravitational-wave transients can be localized on the sky. This is crucial for correctly identifying electromagnetic counterparts as well as understanding gravitational-wave physics and source populations. We present a study of sky localization capabilities for two search and parameter estimation algorithms: coherent WaveBurst, a constrained likelihood algorithm operating in close to real-time, and LALInferenceBurst, a Markov chain Monte Carlo parameter estimation algorithm developed to recover generic transient signals with latency of a few hours. Furthermore, we focus on the first few years of the advanced detector era, when we expect to only have two (2015) and later three (2016) operational detectors, all below design sensitivity. These detector configurations can produce significantly different sky localizations, which we quantify in detail. We observe a clear improvement in localization of the average detected signal when progressing from two-detector to three-detector networks, as expected. Although localization depends on the waveform morphology, approximately 50% of detected signals would be imaged after observing 100-200 deg{sup 2} in 2015 and 60-110 deg{sup 2} in 2016, although knowledge of the waveform can reduce this to as little as 22 deg{sup 2}. This is the first comprehensive study on sky localization capabilities for generic transients of the early network of advanced LIGO and Virgo detectors, including the early LIGO-only two-detector configuration.

79 ASTRONOMY AND ASTROPHYSICS↗

Mercury Speciation of Hanford 241-AP-107 Tank Waste Samples - 20384

The concentration of key mercury species in the Hanford tank waste has not been previously measured. Based on process knowledge, an estimated inventory of 2,100 kg of mercury is assumed and was distributed in varied amounts across 149 single-shell tanks (SSTs) and 28 double-shell tanks (DSTs). Limited analyses of individual SSTs and DSTs for total mercury were all below detection, yielding upper limits in concentration estimates based solely on instrument detection limits, resulting in an uncertain mercury inventory for Hanford tanks. Accurate and reliable chemical speciation and quantification is desired to anticipate, predict, and abate the mass movements of various mercury species through the Hanford waste processing flowsheet. Highly sensitive separation and quantification methods for total, elemental, and monomethyl mercury species, in tank waste, have been developed at the Pacific Northwest National Laboratory's (PNNL) Radiochemical Processing Laboratory (RPL). A non-radiological environmental method to quantify mercury species has been adapted for application to Hanford tank 241-AP-107 raw supernatant feed, filtered feed, and cesium-decontaminated samples. These samples represent feed inventory and pretreatment process effluents prior to immobilization by vitrification. This method separates and preconcentrates total, elemental, and monomethyl mercury onto selective solid substrates with little-to-no radioactive background. The solid samples can then be released from strict radiological control, allowing for analytical work to be conducted in low-level radiological facilities. Separation of mercury species was demonstrated at PNNL's RPL in Richland, Washington before transport and analytical quantification using cold vapor atomic fluorescence spectrometry (CVAFS) at PNNL's Marine Science Laboratory (MSL) in Sequim, Washington. Additional studies were conducted to assess the stability of monomethyl mercury in distilled matrices and preconcentrated onto the Carbotrap{sup R} solid substrate to assess sample degradation over time during transport. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Cameras for the COSMO K-coronagraph

Digital image sensors are ubiquitous in astronomical instrumentation and it is well known that they suffer from issues that must be corrected for data to be scientifically useful. I present discussion on errors resulting from digitization and characterization of nonlinearity and ADC errors of the PhotonFocus MV-D1024E cameras selected for the K-coronagraph of the Coronal Solar Magnetism Observatory. I derive an analytic expression for quantization errors. The MV-D1024E camera has adequate bit depth for which quantization error is not an issue. I show that this is not the case for all cameras, particularly those with deep wells and low read noise. The impact of nonlinearity and ADC errors on science observations of the K-coronagraph is analyzed using a simplified telescope model. Errors caused by the camera ADCs result in systematic errors in the measurement of the polarimetric signal of several times 10{sup −9} B {sub ⊙}, which is about an order of magnitude above the desired sensitivity. I demonstrate a method for post-facto data correction using a lookup table and derive parameters from camera characterization measurements that were made with a lab setup. Nonlinearity is traditionally addressed with a global correction. I show through analysis of calibration data that for the MV-D1024E this correction leaves residual systematic errors after dark and gain correction of up to 1% of the signal. I demonstrate that a pixel-wise correction of nonlinearity reduces the errors to below 0.1%. These corrections are necessary for the K-coronagraph data products to meet the science requirements. They have been implemented in the instrument data acquisition system and data reduction pipeline. While no other instruments besides the K-coronagraph or cameras besides the MV-D1024E are discussed here, the results are illustrative for all instruments and cameras.

79 ASTRONOMY AND ASTROPHYSICS↗

Outgassing of casted and 3D printed silicones

Outgassing of 3D printed and casted silica-filled silicones was studied using a standard ASTM E-595 procedure and a modified Soreq’s method that allows very sensitive measurements of the outgassing kinetics even at low temperatures, 20 – 50 °C. We studied three different silica-filled silicones, non-porous cased M9787, and 3D printed LL50 and 40P materials. The present report shows that vacuum outgassing products of polysiloxane-based materials include multiple species. In addition to chemisorbed and physisorbed water outgassing, previously studied by TPD, polymer fragments of varying sizes evaporate as well. The chemical composition of the condensable volatile species collected on a Germanium substrate, was analyzed by FTIR. It was shown that all studied materials produce mostly PDMS-based outgassing products that form stable droplet-like structure on the Ge substrate. The highest amount of the condensable volatile species was measured for LL50. Isothermal TGA in nitrogen atmosphere of the LL50 material was compared to the standard vacuum outgassing. The results of TGA showed lower mass loss and higher water regain. The kinetics of the outgassing at relatively low temperatures of 20, 30 and 50 °C was studied using Thermoelectric Quartz Crystal Microbalance (TQCM). The TQCM surface was held at -10 °C to enhance condensation of the outgassed moisture. The analysis presented here, when combined with the extensive previous work on moisture outgassing, provides a better understanding of the aging mechanism of polysiloxane-based materials. In this work we show that outgassing techniques, usually applied for qualification of polymers for space-related applications, may be used as a complementary method to study thermal degradation and aging of silica-based silicones. Our results indicate that the long-term degradation mechanics and thermal degradation products depend primarily on the chemical composition of silicone-based material and only slightly affected by the manufacturing process. Surprisingly, the surface-to-volume ratio of the 3D printed vs. casted/molded materials showed only minor effect on the outgassing kinetic parameters.

36 MATERIALS SCIENCE↗

(U) Using the MCNP6 Perturbation Capability for Source Nuclide Density Sensitivities

The Taylor series (differential operator) perturbation method, as implemented in the PERT capability in MCNP6 (Ref. 1), can be used for first- and second-order sensitivity analyses in fixed-source problems. Unfortunately, the PERT capability does not yet work with point-detector (F5) or pulse-height (F8) tallies. Also, the second-order Taylor series term lacks the cross terms that would allow the calculation of mixed sensitivities. Finally, the PERT capability does not compute any sensitivities involving the source in a fixed-source problem. When neutrons or gamma rays are emitted due to radioactive decay, the source rate density depends intrinsically on the nuclide densities in the source material. When the PERT capability in MCNP6 is used to compute sensitivities of a response to nuclide and material densities, those sensitivities do not include the effect of the source.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-105: Development of 3D Dose Verification System for Volumetric Modulated Arc Therapy Using Improved Polyacrylamide-Based Gel Dosimeter

Purpose: The aim of this dosimetric study was to develop 3D dose verification system for volumetric modulated arc therapy (VMAT) using polyacrylamide-based gel (PAGAT) dosimeter improved the sensitivity by magnesium chloride (MgCl{sub 2}). Methods: PAGAT gel containing MgCl{sub 2} as a sensitizer was prepared in this study. Methacrylic-acid-based gel (MAGAT) was also prepared to compare the dosimetric characteristics with PAGAT gel. The cylindrical glass vials (4 cm diameter, 12 cm length) filled with each polymer gel were irradiated with 6 MV photon beam using Novalis Tx linear accelerator (Varian/BrainLAB). The irradiated polymer gel dosimeters were scanned with Signa 1.5 T MRI system (GE), and dose calibration curves were obtained using T{sub 2} relaxation rate (R{sub 2} = 1/T{sub 2}). Dose rate (100-600 MU min{sup −1}) and fractionation (1-8 fractions) were varied. In addition, a cubic acrylic phantom (10 × 10 × 10 cm{sup 3}) filled with improved PAGAT gel inserted into the IMRT phantom (IBA) was irradiated with VMAT (RapidArc). C-shape structure was used for the VMAT planning by the Varian Eclipse treatment planning system (TPS). The dose comparison of TPS and measurements with the polymer gel dosimeter was accomplished by the gamma index analysis, overlaying the dose profiles for a set of data on selected planes using in-house developed software. Results: Dose rate and fractionation dependence of improved PAGAT gel were smaller than MAGAT gel. A high similarity was found by overlaying the dose profiles measured with improved PAGAT gel dosimeter and the TPS dose, and the mean pass rate of the gamma index analysis using 3%/3 mm criteria was achieved 90% on orthogonal planes for VMAT using improved PAGAT gel dosimeter. Conclusion: In-house developed 3D dose verification system using improved polyacrylamide-based gel dosimeter had a potential as an effective tool for VMAT QA.

60 APPLIED LIFE SCIENCES↗

Understanding the Effect of Baseline Modeling Implementation Choices on Analysis of Demand Response Performance

Accurate evaluation of the performance of buildings participating in Demand Response (DR) programs is critical to the adoption and improvement of these programs. Typically, we calculate load sheds during DR events by comparing observed electric demand against counterfactual predictions made using statistical baseline models. Many baseline models exist and these models can produce different shed calculations. Moreover, modelers implementing the same baseline model can make different modeling implementation choices, which may affect shed estimates. In this work, using real data, we analyze the effect of different modeling implementation choices on shed predictions. We focused on five issues: weather data source, resolution of data, methods for determining when buildings are occupied, methods for aligning building data with temperature data, and methods for power outage filtering. Results indicate sensitivity to the weather data source and data filtration methods as well as an immediate potential for automation of methods to choose building occupied modes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Molten Salt Electrochemical Reactors Outside of a Glovebox

Molten salt electrochemical reduction (MSER) offers an electrified method for the reduction, refining, and recycling of metals such as iron and metallurgical grade silicon at high efficiency and lower temperatures than traditional methods, which use temperatures >1000C and carbon-based reductants. However, salts appropriate for MSER are moisture and air sensitive, necessitating air-free methods of processing and testing which is often acomplished with a glovebox. Glovebox operations are cumbersome and difficult to troubleshoot reactor issues. We have developed a robust method of testing chloride and carbonate salts in molten salt reactors outside of a glovebox for silicon and carbon production and steel carburization. We highlight a practical guide for glovebox-free testing of molten salt electrochemical reactors to reduce the barriers to performing this type of work. Our aim is to enable other research groups to step into this field with simple and repeatable reactor configurations.

47 OTHER INSTRUMENTATION↗

Sensitivity of the CUORE detector to 14.4 keV solar axions emitted by the M1 nuclear transition of {sup 57}Fe

In this paper we present a calculation of the sensitivity of the CUORE detector to the monoenergetic 14.4 keV solar axions emitted by the M1 nuclear transition of {sup 57}Fe in the Sun and detected by inverse coherent Bragg-Primakoff conversion in single-crystal TeO{sub 2} bolometers. The expected counting rate is calculated using density functional theory for the electron charge density of TeO{sub 2} and realistic background and energy resolution of CUORE. Monte Carlo simulations for 5y × 741 kg=3705 kg y of exposure are analyzed using time correlation of individual events with the theoretical time-dependent counting rate. We find an expected model-independent limit on the product of the axion-photon coupling and the axion-nucleon coupling g{sub aγγ}g{sub aN}{sup eff} < 1.105 × 10{sup −16} /GeV for axion masses less than 500 eV with 95% confidence level.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of exposure damage in composite materials using Fourier transform infrared technology.

Goal: to detect the subtle changes in laminate composite structures brought about by thermal, chemical, ultraviolet, and moisture exposure. Compare sensitivity of an array of NDI methods, including Fourier Transform Infrared Spectroscopy (FTIR), to detect subtle differences in composite materials due to deterioration. Inspection methods applied: ultrasonic pulse echo, through transmission ultrasonics, thermography, resonance testing, mechanical impedance analysis, eddy current, low frequency bond testing & FTIR. Comparisons between the NDI methods are being used to establish the potential of FTIR to provide the necessary sensitivity to non-visible, yet significant, damage in the resin and fiber matrix of composite structures. Comparison of NDI results with short beam shear tests are being used to relate NDI sensitivity to reduction in structural performance. Chemical analyses technique, which measures the infrared intensity versus wavelength of light reflected on the surface of a structure (chemical and physical information via this signature). Advances in instrumentation have resulted in hand-held portable devices that allow for field use (few seconds per scan). Shows promise for production quality assurance and in-service applications on composite aircraft structures (scarfed repairs). Statistical analysis on frequency spectrums produced by FTIR interrogations are being used to produce an NDI technique for assessing material integrity. Conclusions are: (1) Use of NDI to assess loss of composite laminate integrity brought about by thermal, chemical, ultraviolet, and moisture exposure. (2) Degradation trends between SBS strength and exposure levels (temperature and time) have been established for different materials. (3) Various NDI methods have been applied to evaluate damage and relate this to loss of integrity - PE UT shows greatest sensitivity. (4) FTIR shows promise for damage detection and calibration to predict structural integrity (short beam shear). (5) Detection of damage for medium exposure levels (possibly resin matrix degradation only) is more difficult and requires additional study. (6) These are initial results only - program is continuing with additional heat, UV, chemical and water exposure test specimens.

36 MATERIALS SCIENCE↗

MicroRNA-223 Enhances Radiation Sensitivity of U87MG Cells In Vitro and In Vivo by Targeting Ataxia Telangiectasia Mutated

Purpose: Ataxia telangiectasia mutated (ATM) protein is important in the DNA damage response because it repairs radiation-induced damage in cancers. We examined the effect of microRNA-223 (miR-223), a regulator of ATM expression, on radiation sensitivity of cancer cells. Methods and Materials: Human embryonic kidney 293 T (293T) cells were infected with pLL3.7-miR-223 plasmid to generate the pLL3.7-miR-223 and -empty virus (EV) lentivirus (miR-223 and EV). A dual luciferase assay in which the reporter contained wild-type 3′ untranslated region (UTR) of ATM was performed. U87MG cells were infected with miR-223 or EV to establish the overexpressed stable cell lines (U87-223 or U87-EV, respectively). Cells were irradiated in vitro, and dose enhancement ratios at 2 Gy (DER{sub 2}) were calculated. Hind legs of BALB/c athymic mice were injected with U87-223 or U87-EV cells; after 2 weeks, half of the tumors were irradiated. Tumor volumes were tracked for a total of 5 weeks. Results: The dual luciferase reporter assay showed a significant reduction in luciferase activity of 293T cells cotransfected with miR-223 and the ATM 3′UTR compared to that in EV control. Overexpression of miR-223 in U87MG cells showed that ATM expression was significantly downregulated in the U87-223 cells compared to that in U87-EV (ATM/β-actin mRNA 1.0 vs 1.5, P<.05). U87-223 cells were hypersensitive to radiation compared to U87-EV cells in vitro (DER{sub 2} = 1.32, P<.01). Mice injected with miR-223-expressing tumors had almost the same tumors after 3 weeks (1.5 cm{sup 3} vs 1.7 cm{sup 3}). However, irradiation significantly decreased tumor size in miR-223-expressing tumors compared to those in controls (0.033 cm{sup 3} vs 0.829 cm{sup 3}). Conclusions: miR-223 overexpression downregulates ATM expression and sensitizes U87 cells to radiation in vitro and in vivo. MicroRNA-223 may be a novel cancer-targeting therapy, although its cancer- and patient-specific roles are currently undefined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Video-rate optical dosimetry and dynamic visualization of IMRT and VMAT treatment plans in water using Cherenkov radiation

Purpose: A novel technique for optical dosimetry of dynamic intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) plans was investigated for the first time by capturing images of the induced Cherenkov radiation in water. Methods: A high-sensitivity, intensified CCD camera (ICCD) was configured to acquire a two-dimensional (2D) projection image of the Cherenkov radiation induced by IMRT and VMAT plans, based on the Task Group 119 (TG-119) C-Shape geometry. Plans were generated using the Varian Eclipse treatment planning system (TPS) and delivered using 6 MV x-rays from a Varian TrueBeam Linear Accelerator (Linac) incident on a water tank doped with the fluorophore quinine sulfate. The ICCD acquisition was gated to the Linac target trigger pulse to reduce background light artifacts, read out for a single radiation pulse, and binned to a resolution of 512 × 512 pixels. The resulting videos were analyzed temporally for various regions of interest (ROI) covering the planning target volume (PTV) and organ at risk (OAR), and summed to obtain an overall light intensity distribution, which was compared to the expected dose distribution from the TPS using a gamma-index analysis. Results: The chosen camera settings resulted in 23.5 frames per second dosimetry videos. Temporal intensity plots of the PTV and OAR ROIs confirmed the preferential delivery of dose to the PTV versus the OAR, and the gamma analysis yielded 95.9% and 96.2% agreement between the experimentally captured Cherenkov light distribution and expected TPS dose distribution based upon a 3%/3 mm dose difference and distance-to-agreement criterion for the IMRT and VMAT plans, respectively. Conclusions: The results from this initial study demonstrate the first documented use of Cherenkov radiation for video-rate optical dosimetry of dynamic IMRT and VMAT treatment plans. The proposed modality has several potential advantages over alternative methods including the real-time nature of the acquisition, and upon future refinement may prove to be a robust and novel dosimetry method with both research and clinical applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Determination of the solid angle and response function of a hemispherical spectrograph with injection lens for Auger electrons emitted from long lived projectile states

We present SIMION 8.1 Monte Carlo type simulations of the response function and detection solid angle for long lived Auger states (lifetime τ ∼ 10{sup −9} − 10{sup −5} s) recorded by a hemispherical spectrograph with injection lens and position sensitive detector used for high resolution Auger spectroscopy of ion beams. Also included in these simulations for the first time are kinematic effects particular to Auger emission from fast moving projectile ions such as line broadening and solid angle limitations allowing for a more accurate and realistic line shape modeling. Our results are found to be in excellent agreement with measured electron line shapes of both long lived 1s2s2p{sup 4}P and prompt Auger projectile states formed by electron capture in collisions of 25.3 MeV F{sup 7+} with H{sub 2} and 12.0 MeV C{sup 4+} with Ne recorded at 0{sup ∘} to the beam direction. These results are important for the accurate evaluation of the 1s2s2p {sup 4}P/{sup 2}P ratio of K-Auger cross sections whose observed non-statistical production by electron capture into He-like ions, recently a field of interesting interpretations, awaits further resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-FG-BRA-11: Theranostic Platinum Nanoparticle for Radiation Sensitization in Breast Cancer Radiotherapy

Purpose: We have developed a novel receptor-targeted theranostic platinum nanoparticle (HER-PtNP) for enhanced radiation sensitization in HER2-positive breast cancer radiation treatment. This study aims to evaluate receptor-targeting specificity, and radiation sensitization of the nanoparticle. Methods: The platinum nanoparticle (PtNP) was synthesized with the diameter of 2nm, and capped with cysteine. The nanoparticle was tagged with a fluorescent dye (cy5) for the fluoresence detection, and conjuated with HER2/3 targeted protein (HerPBK10) for HER2-targeting specificity. We evaluated the theranostic features using in vitro breast cancer cell models: HER2-positive BT-474, and HER2-negative MDA-MB-231. The HER2-targeting specificity was evaluated using immunofluorescence and confocal microscopy. For each cell line, three sets of samples, including non-stained control, fluorescence stained PtNP-cy5 treated, and HER-PtNP treated, were imaged by confocal microscopy. Two breast cancer cell lineages were incubated with PtNP and HER-PtNP at 10 µg/mL, and then irradiated with X-rays for 2 Gy dose at 50 kVp. A colonogenic assay was used to determine cellular survival fractions by immediately reseeding 300 cells after irradiation in growth media and allowing colonies to grow for 2 weeks. Results: The results of confocal images show that no apparent nanoparticle cellular uptake was observed in the HER2-(MDA-MB-231) cells with 1% for PtNP-cy5 and 0.5% for HER-PtNP. Similarly no apparent PtNP-cy5 uptake (<1%) for BT474 cells was observed. However, there was significant HER-PtNP uptake (73%) for the HER2+(BT474) cells. The clonogenic assay showed that BT474 cells treated with HER-PtNP had significantly lower survival compared to those treated with PtNP (32% vs 81%, p=0.01). However, no significant radiosensitivity enhancement was observed for MDA-MB-231 cell treated with PtNP and HER-PtNP (89% vs 92%, p=0.78). Conclusion: Our studies suggest that the HER2-targeted platinum nanoparticle has excellent receptor targeting specificity and enhanced radiation sensitization compared to nanoparticle alone, suggesting potential for clinical applications in breast cancer radiotherapy.

60 APPLIED LIFE SCIENCES↗

Ion transport in sub-5-nm graphene nanopores

Graphene nanopore is a promising device for single molecule sensing, including DNA bases, as its single atom thickness provides high spatial resolution. To attain high sensitivity, the size of the molecule should be comparable to the pore diameter. However, when the pore diameter approaches the size of the molecule, ion properties and dynamics may deviate from the bulk values and continuum analysis may not be accurate. In this paper, we investigate the static and dynamic properties of ions with and without an external voltage drop in sub-5-nm graphene nanopores using molecular dynamics simulations. Ion concentration in graphene nanopores sharply drops from the bulk concentration when the pore radius is smaller than 0.9 nm. Ion mobility in the pore is also smaller than bulk ion mobility due to the layered liquid structure in the pore-axial direction. Our results show that a continuum analysis can be appropriate when the pore radius is larger than 0.9 nm if pore conductivity is properly defined. Since many applications of graphene nanopores, such as DNA and protein sensing, involve ion transport, the results presented here will be useful not only in understanding the behavior of ion transport but also in designing bio-molecular sensors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cascade annealing simulations of bcc iron using object kinetic Monte Carlo

Simulations of displacement cascade annealing were carried out using object kinetic Monte Carlo based on an extensive MD database including various primary knock-on atom energies and directions. The sensitivity of the results to a broad range of material and model parameters was examined. The diffusion mechanism of interstitial clusters has been identified to have the most significant impact on the fraction of stable interstitials that escape the cascade region. The maximum level of recombination was observed for the limiting case in which all interstitial clusters exhibit 3D random walk diffusion. The OKMC model was parameterized using two alternative sets of defect migration and binding energies, one from ab initio calculations and the second from an empirical potential. The two sets of data predict essentially the same fraction of surviving defects but different times associated with the defect escape processes. This study provides a comprehensive picture of the first phase of long-term defect evolution in bcc iron and generates information that can be used as input data for mean field rate theory (MFRT) to predict the microstructure evolution of materials under irradiation. In addition, the limitations of the current OKMC model are discussed and a potential way to overcome these limitations is outlined.

36 MATERIALS SCIENCE↗

Projection imaging of photon beams by the Cerenkov effect

Purpose: A novel technique for beam profiling of megavoltage photon beams was investigated for the first time by capturing images of the induced Cerenkov emission in water, as a potential surrogate for the imparted dose in irradiated media. Methods: A high-sensitivity, intensified CCD camera (ICCD) was configured to acquire 2D projection images of Cerenkov emission from a 4 Multiplication-Sign 4 cm{sup 2} 6 MV linear accelerator (LINAC) x-ray photon beam operating at a dose rate of 400 MU/min incident on a water tank with transparent walls. The ICCD acquisition was gated to the LINAC sync pulse to reduce background light artifacts, and the measurement quality was investigated by evaluating the signal to noise ratio and measurement repeatability as a function of delivered dose. Monte Carlo simulations were used to derive a calibration factor for differences between the optical images and deposited dose arising from the anisotropic angular dependence of Cerenkov emission. Finally, Cerenkov-based beam profiles were compared to a percent depth dose (PDD) and lateral dose profile at a depth of d{sub max} from a reference dose distribution generated from the clinical Varian ECLIPSE treatment planning system (TPS). Results: The signal to noise ratio was found to be 20 at a delivered dose of 66.6 cGy, and proportional to the square root of the delivered dose as expected from Poisson photon counting statistics. A 2.1% mean standard deviation and 5.6% maximum variation in successive measurements were observed, and the Monte Carlo derived calibration factor resulted in Cerenkov emission images which were directly correlated to deposited dose, with some spatial issues. The dose difference between the TPS and PDD predicted by Cerenkov measurements was within 20% in the buildup region with a distance to agreement (DTA) of 1.5-2 mm and {+-}3% at depths beyond d{sub max}. In the lateral profile, the dose difference at the beam penumbra was within {+-}13% with a DTA of 0-2 mm, {+-}5% in the central beam region, and 2%-3% in the beam umbra. Conclusions: The results from this initial study demonstrate the first documented use of Cerenkov emission imaging to profile x-ray photon LINAC beams in water. The proposed modality has several potential advantages over alternative methods, and upon future refinement may prove to be a robust and novel dosimetry method.

61 RADIATION PROTECTION AND DOSIMETRY↗