Search NASA⌕ Search

SEARCH · Search NASA

Results for “static testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Flow characteristics in an expansion tunnel as inferred from velocity measurements

A photoionization technique was used to study flow characteristics in an expansion tunnel. Vertical surveys of the axial component of flow velocity just downstream from the nozzle exit were obtained, and estimates of freestream density were inferred from the velocity measurement technique. The pitot pressure was measured and compared to the average axial component of velocity as a function of time for the two cases when air and CO2 were used as test gases. Vertical velocity and static density profiles at the nozzle exit are presented for the case when CO2 was used as test gas. Experimental results were used to determine the diameter and uniformity of the test core at the nozzle exit and the duration of the quasi-steady flow period. These data are relevant to evaluation of the suitability of operating an expansion tube as an expansion tunnel. The expansion tunnel is an expansion tube with a conical nozzle positioned at the exit of the acceleration section, so that nozzle entrance flow conditions are hypersonic and characterized by hypervelocity.

Miller, C. G.↗

Analysis and testing of a space crane articulating joint testbed

The topics are presented in viewgraph form and include: space crane concept with mobile base; mechanical versus structural articulating joint; articulating joint test bed and reference truss; static and dynamic characterization completed for space crane reference truss configuration; improved linear actuators reduce articulating joint test bed backlash; 1-DOF space crane slew maneuver; boom 2 tip transient response finite element dynamic model; boom 2 tip transient response shear-corrected component modes torque driver profile; peak root member force vs. slew time torque driver profile; and open loop control of space crane motion.

Thomas R Sutter↗

Microcracking, microcrack-induced delamination, and longitudinal splitting of advanced composite structures

A combined analytical and experimental study was conducted to analyze microcracking, microcrack-induced delamination, and longitudinal splitting in polymer matrix composites. Strain energy release rates, calculated by a variational analysis, were used in a failure criterion to predict microcracking. Predictions and test results were compared for static, fatigue, and cyclic thermal loading. The longitudinal splitting analysis accounted for the effects of fiber bridging. Test data are analyzed and compared for longitudinal splitting and delamination under mixed-mode loading. This study emphasizes the importance of using fracture mechanics analyses to understand the complex failure processes that govern composite strength and life.

Nairn, John A.↗

Evaluation of selected strapdown inertial instruments and pulse torque loops, volume 1

Design, operational and performance variations between ternary, binary and forced-binary pulse torque loops are presented. A fill-in binary loop which combines the constant power advantage of binary with the low sampling error of ternary is also discussed. The effects of different output-axis supports on the performance of a single-degree-of-freedom, floated gyroscope under a strapdown environment are illustrated. Three types of output-axis supports are discussed: pivot-dithered jewel, ball bearing and electromagnetic. A test evaluation on a Kearfott 2544 single-degree-of-freedom, strapdown gyroscope operating with a pulse torque loop, under constant rates and angular oscillatory inputs is described and the results presented. Contributions of the gyroscope's torque generator and the torque-to-balance electronics on scale factor variation with rate are illustrated for a SDF 18 IRIG Mod-B strapdown gyroscope operating with various pulse rebalance loops. Also discussed are methods of reducing this scale factor variation with rate by adjusting the tuning network which shunts the torque coil. A simplified analysis illustrating the principles of operation of the Teledyne two-degree-of-freedom, elastically-supported, tuned gyroscope and the results of a static and constant rate test evaluation of that instrument are presented.

Sinkiewicz, J. S.↗

The effect of 0.1 atomic percent zirconium on the cyclic oxidation behavior of beta-NiAl for 300 hours at 1200 C

The long time effect of 0.1 at percent Zr (0.2 wt percent Zr) on the cyclic oxidation behavior of hipped beta-NiAl was studied. Oxidation testing was performed in static air at 1200 C for up to 3000 one-hour exposure cycles. Specific weight change versus time data was modeled with the COSP computer program to analyze cyclic oxidation behavior. The Zr-free stoichiometric alloy oxidized and spalled randomly to bare metal between cycles at a rate high enough to deplete Al to a low enough level that oxidation breakaway took place as nonprotective NiO replaced the alpha-Al2O3/NiAl2O4 scale as the controlling oxide. The Zr minimized this severe type of spalling maintaining the protective alpha-Al2O3 scale even out to 3000 hours for the stoichiometric alloy with no significant Al depletion. A third beta-NiAl alloy containing 0.1 at percent Zr but with 10 percent less Al than the stoichiometric alloy was also tested and showed some depletion of Al, but the protective Al2O3/NiAl2O4 was still maintained to close to 2700 hours.

Barrett, C. A.↗

The effect of 0.1 atomic percent zirconium on the cyclic oxidation behavior of beta-NiAl for 3000 hours at 1200 C

The long time effect of 0.1 at percent Zr (0.2 wt percent Zr) on the cyclic oxidation behavior of hipped beta-NiAl was studied. Oxidation testing was performed in static air at 1200 C for up to 3000 one-hour exposure cycles. Specific weight change versus time data was modeled with the COSP computer program to analyze cyclic oxidation behavior. The Zr-free stoichiometric alloy oxidized and spalled randomly to bare metal between cycles at a rate high enough to deplete Al to a low enough level that oxidation breakaway took place as nonprotective NiO replaced the alpha-Al203/NiAl204 scale as the controlling oxide. The Zr minimized this severe type of spalling maintaining the protective alpha-Al203 scale even out to 3000 hours for the stoichiometric alloy with no significant Al depletion. A third beta-NiAl alloy containing 0.1 at percent Zr but with 10 percent less Al than the stoichiometric alloy was also tested and showed some depletion of Al, but the protective Al203/NiAl204 was still maintained to close to 2700 hours.

Barrett, C. A.↗

Renewed experimentation with Ranchero flux compression genereators

In the late 1990s, Los Alamos pursued a coaxial flux compression generator (FCG) concept that was described in several publications under the name 'Ranchero.' These FCGs were designed to be cost effective high current generators, and a variety of configurations were tested. The Ranchero armature is a 152 mm diameter aluminum cylinder with a 6 mm thick wall. The high explosive (HE) is detonated simultaneously on axis, and as the armature expands a factor of two, the wall thins to {approx}3 mm. At the final 300 mm diameter, the circumference is over 900 mm, and this should allow currents to be generated in the 90 MA range. No tests significantly over 50 MA have been performed but an experiment is planned. We have recently begun using Ranchero devices for a new application and we continue to improve the design. In this paper we describe recent tests of Ranchero and its subsystems. The load for our new application is an imploding aluminum liner that would deform due to the magnetic pressure applied during the initial flux loading. It will, however, implode properly when powered only during the {approx}29 {micro}s Ranchero flux compression time. This gives rise to a new system with explOSively formed fuse (EFF) opening switches and an integral closing switch that isolates the load. A capacitor bank delivers 2.8 MA to the Ranchero circuit in {approx}85 {micro}s. During this time, four parallel 63.5 mm wide EFFs, external to the coaxial system, complete the circuit. After armature motion begins, insulation which initially isolates the load is severed, connecting the load to the FCG in parallel with the EFFs. External HE charges are initiated on each of the EFFs to produce a resistance rise timed to not precede closure of the load isolation switch. The EFFs achieve significant resistance, and the flux remaining in the 191 nH generator and 3 nH transmission line is compressed to generate 30.85 MA in a {approx}12.5 nH static load. On three tests, the EFF system has operated flawlessly, and only {approx}100kA is driven back into the EFFs during peak voltage of the generator output. A test incorporating a 19.5 nH dual liner dynamic load has also been completed, and these results are also presented. Ranchero generators have been operated with armatures from 43 cm to 1.4 m long, corresponding to initial inductances from 56 to 191 nH. MHD code modeling gives better agreement with experiments using modules 43 cm long than the 1.4 m modules, and these results will also be presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Core/Combustor-Noise Measurements and Source Separation for the DGEN Aeropropulsion Research Turbofan

Acoustic data obtained using a small turbofan engine are further analyzed with the aim to ultimately enable improved prediction methods and mitigation techniques for turbofan core/combustor noise. The relative impact of this propulsion-noise source for civilian-transport aircraft on airport community noise is expected to significantly increase in the future. Simultaneous high-data-rate acoustic measurements acquired using a circumferential infinite-tube-probe array at the core-nozzle exit in conjunction with a far-field microphone array are processed. The test matrix contains engine operational points from idle to engine-maximum setting, with measurements repeated for different circumferential array configurations, as well as for redundancy. The combustor-noise contribution to the far-field noise signature is obtained using an advanced source-separation method that correlates far-field microphone measurements with a modal decomposition of the unsteady pressure field at the core-nozzle exit. The advantages of the present approach compared to the classical two-signal source-separation method are discussed.

Aeroacoustics↗

Seismic and LOCA safety testing and analysis program for Westinghouse PWR fuel under end of life conditions

The NRC issued Information Notice - IN 2012-09 in June 2012 which challenges approved assumptions based on the beginning of life (BOL) conditions in seismic and LOCA analysis. Westinghouse manufactures a variety of PWR fuel designs, including 14*14, 15*15, 16*16 and 17*17 array, also different fuel lengths from 12 feet to 14 feet. The fuels are supplied to the cores designed by Westinghouse and Combustion Engineering, and other cores around world. To address IN 2012-09 efficiently and economically, Westinghouse and PWR Owner Groups launched a testing and analysis program funded by PWROG. The program planed testing and analysis matrices based on types of fuel designs. The testing plan includes grid crush tests, fuel assembly mechanical tests and flowing water damping tests. Applying modelling technique, the program will reduce the number of test and cost. The ultimate goal of the program is to generate fuel assembly EOL models for all fuel designs manufactured by Westinghouse and to be ready for any plant specific seismic and LOCA analysis to address NRC IN for EOL effect. The phase I of PWROG for EOL conditions has been completed and several conclusions are obtained. First, the gapped grids reduce grid dynamic stiffness, local impact stiffness and crush strength. Also, due to gapped grids, both the fuel assembly natural frequency and stiffness are reduced. Secondly, applying higher fuel assembly damping due to the flowing water effect can significantly reduce fuel assembly impact forces. However, during a seismic event the reactor coolant pumps may trip resulting in a coast-down. As such, reduced flow rates that occur during the pump coast-down must be considered. Thirdly, the analytical model representation of a reactor core adequately characterizes the core response under seismic and LOCA excitations. Static and dynamic structural test results of a fuel assembly compared with analytical predictions indicate that the fuel assembly lateral and axial structural behavior can be fully determined with finite element models. Fourthly, analyses for EOL fuel assemblies under seismic and LOCA loads demonstrate EOL effect and flowing water damping effect. With flowing water damping benefit, significant margin can be recovered for fuel assemblies with EOL conditions and under seismic loads.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dynamic tester for rotor seals and bearings

A dynamic tester for testing vibration damping seals and bearings is constructed having a hollow shaft extending through the seal or bearing, with the shaft internally supported at each end by fluid bearings on hollow bosses connected to an interior of an enclosure, with no rolling members connected to the shaft is described. A high pressure working fluid is forced through the hollow bosses to operate the bearings. Additionally, the shaft is provided with a reaction turbine that angularly vents a portion of the high pressure working fluid in order to rotate the shaft at high speed, up to 40,000 rpm. The seal or bearing is mounted in a bushing, in turn supported by rods to a shaking device that vibrates the seal or bearing as the shaft is rotated. A plurality of proximity sensors are mounted from outside the enclosure to sense shaft and seal bushing vibrations, and a plurality of pressure ports are disposed in the enclosure to allow sensing of dynamic and static pressures of the testing apparatus.

Vonpragenau, George L.↗

Static performance of five twin-engine nonaxisymmetric nozzles with vectoring and reversing capability

Transonic tunnel test was performed to determine the static performance of five twin-engine nonaxisymmetric nozzles and a base-line axisymmetric nozzle at three nozzle power settings. Static thrust-vectoring and thrust-reversing performance were also determined. Nonaxisymmetric-nozzle concepts included two-dimensional convergent-divergent nozzles, wedge nozzles, and a nozzle with a single external-expansion ramp. All nonaxisymmetric nozzles had essentially the same statis performance as the axisymmetric nozzle. Effective thrust vectoring and reversing was also achieved.

Capone, F. J.↗

Determination of longitudinal and lateral directional aerodynamic characteristics of the B19B pressure-fed booster and the B19B booster/040A orbiter launch configuration

The 0.003366 scale models of the space shuttle pressure-fed booster and booster/orbiter configurations were tested in the MSFC 14-inch trisonic wind tunnel. The test was conducted as a static stability and control investigation over a Mach range of 0.60 to 5.00. The booster alone configuration was tested with various tail sizes, tail wedge angles, tail flaps, spoilers, and a body flare drag skirt. Two launch configurations were tested; one being the MSC orbiter location on the booster tank and the other being the North American Rockwell orbiter location. Orbiter buildup, longitudinal position, incidence angle, and booster tail on and off were the variables for launch configuration. Booster alone models were pitched over an angle of attack range of -4 to +14 and +20 to +60 deg at zero deg yaw angle and yawed over an angle of sideslip range of -10 to +10 deg at 52 deg angle of attack. Launch configuration models were yawed -10 to +10 deg at zero degrees angle of attack and yawed -10 to +10 deg at zero and -6 deg angle of attack. All models were rolled 45 deg during selected runs.

Mcginnis, R. F.↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Static and Dynamic Friction Behavior of Candidate High Temperature Airframe Seal Materials

The following report describes a series of research tests to evaluate candidate high temperature materials for static to moderately dynamic hypersonic airframe seals. Pin-on-disk reciprocating sliding tests were conducted from 25 to 843 C in air and hydrogen containing inert atmospheres. Friction, both dynamic and static, was monitored and serves as the primary test measurement. In general, soft coatings lead to excessive static friction and temperature affected friction in air environments only.

Dellacorte, C.↗

Experimental study of effects of forebody geometry on high angle of attack static and dynamic stability

A series of low speed wind tunnel tests on a generic fighter model with a cylindrical fuselage were made to investigate the effects of forebody shape on static and dynamic lateral/directional stability. Five forebodies, including a chine nose of unconventional cross-sectional shape, were tested. Conventional force tests were conducted to determine static stability characteristics and single degree-of-freedom free-to-roll tests were used to study the wing rock susceptibility of the model with the various forebodies. Flow visualization data were obtained to aid in analysis of the complex flow phenomena involved. The results show that forebody cross-sectional shape can strongly effect both static and dynamic (roll) stability at high angles of attack. Large variations in stability were obtained for the various forebody geometries. These characteristics result from the impact of cross-sectional shape on forebody vortex development, the behavior of the vortices at sideslip conditions, and their interaction with the wing and empennage flow fields.

Brandon, J. M.↗

Mechanical Properties of DU-xMo Alloys With x = 7-12 Weight Percent

Mechanical properties of six depleted uranium-molybdenum (U-Mo) alloys have been obtained using microhardness, quasistatic tensile tests, and scanning electron microscopy (SEM) failure analysis. U-Mo alloy foils are currently under investigation for potential conversion of high power research reactors to low enriched uranium fuel. Although mechanical properties take on a secondary effect during irradiation, an understanding of the alloy behavior during fabrication and the effects of irradiation on the integrity of the fuel is essential. In general, the microhardness, yield strength, Young’s modulus, and ultimate tensile strength improved with increasing Mo content. Microhardness measurements were very sensitive to local composition, while the failure mode was significantly controlled by the impurity concentration of the alloy, especially carbon. Values obtained from literature are also provided with reasonable agreement, even though processing conditions and applications were quite different in some instances.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

EM reconstruction of dual isotope PET using staggered injections and prompt gamma positron emitters

Purpose: The aim of dual isotope positron emission tomography (DIPET) is to create two separate images of two coinjected PET radiotracers. DIPET shortens the duration of the study, reduces patient discomfort, and produces perfectly coregistered images compared to the case when two radiotracers would be imaged independently (sequential PET studies). Reconstruction of data from such simultaneous acquisition of two PET radiotracers is difficult because positron decay of any isotope creates only 511 keV photons; therefore, the isotopes cannot be differentiated based on the detected energy. Methods: Recently, the authors have proposed a DIPET technique that uses a combination of radiotracer A which is a pure positron emitter (such as{sup 18}F or {sup 11}C) and radiotracer B in which positron decay is accompanied by the emission of a high-energy (HE) prompt gamma (such as {sup 38}K or {sup 60}Cu). Events that are detected as triple coincidences of HE gammas with the corresponding two 511 keV photons allow the authors to identify the lines-of-response (LORs) of isotope B. These LORs are used to separate the two intertwined distributions, using a dedicated image reconstruction algorithm. In this work the authors propose a new version of the DIPET EM-based reconstruction algorithm that allows the authors to include an additional, independent estimate of radiotracer A distribution which may be obtained if radioisotopes are administered using a staggered injections method. In this work the method is tested on simple simulations of static PET acquisitions. Results: The authors’ experiments performed using Monte-Carlo simulations with static acquisitions demonstrate that the combined method provides better results (crosstalk errors decrease by up to 50%) than the positron-gamma DIPET method or staggered injections alone. Conclusions: The authors demonstrate that the authors’ new EM algorithm which combines information from triple coincidences with prompt gammas and staggered injections improves the accuracy of DIPET reconstructions for static acquisitions so they reach almost the benchmark level calculated for perfectly separated tracers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗