Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Atomic data and spectral line intensities for Ni XVII

Electron impact collision strengths, energy levels, oscillator strengths, and spontaneous radiative decay rates are calculated for Ni XVII. We include in the calculations the 23 lowest configurations, corresponding to 159 fine-structure levels: 3l3l', 3l4l'', and 3s5l''', with l, l' = s, p, d, l'' = s, p, d, f, and l''' = s, p, d. Collision strengths are calculated at five incident energies for all transitions at varying energies above the threshold of each transition. One additional energy, very close to the threshold of each transition, has also been included. Calculations have been carried out using the Flexible Atomic Code in the distorted wave approximation. Additional calculations have been performed with the University College London suite of codes for comparison. Excitation rate coefficients are calculated as a function of electron temperature by assuming a Maxwellian electron velocity distribution. Using the excitation rate coefficients and the radiative transition rates of the present work, statistical equilibrium equations for level populations are solved at electron densities covering the range of 10{sup 8} - 10{sup 14} cm{sup -3} and at an electron temperature of log T{sub e}(K) = 6.5, corresponding to the maximum abundance of Ni XVII. Spectral line intensities are calculated, and their diagnostic relevance is discussed. This dataset will be made available in the next version of the CHIANTI database.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Predicting Chest Wall Pain From Lung Stereotactic Body Radiotherapy for Different Fractionation Schemes

Purpose: Recent studies with two fractionation schemes predicted that the volume of chest wall receiving >30 Gy (V30) correlated with chest wall pain after stereotactic body radiation therapy (SBRT) to the lung. This study developed a predictive model of chest wall pain incorporating radiobiologic effects, using clinical data from four distinct SBRT fractionation schemes. Methods and Materials: 102 SBRT patients were treated with four different fractionations: 60 Gy in three fractions, 50 Gy in five fractions, 48 Gy in four fractions, and 50 Gy in 10 fractions. To account for radiobiologic effects, a modified equivalent uniform dose (mEUD) model calculated the dose to the chest wall with volume weighting. For comparison, V30 and maximum point dose were also reported. Using univariable logistic regression, the association of radiation dose and clinical variables with chest wall pain was assessed by uncertainty coefficient (U) and C statistic (C) of receiver operator curve. The significant associations from the univariable model were verified with a multivariable model. Results: 106 lesions in 102 patients with a mean age of 72 were included, with a mean of 25.5 (range, 12-55) months of follow-up. Twenty patients reported chest wall pain at a mean time of 8.1 (95% confidence interval, 6.3-9.8) months after treatment. The mEUD models, V30, and maximum point dose were significant predictors of chest wall pain (p < 0.0005). mEUD improved prediction of chest wall pain compared with V30 (C = 0.79 vs. 0.77 and U = 0.16 vs. 0.11). The mEUD with moderate weighting (a = 5) better predicted chest wall pain than did mEUD without weighting (a = 1) (C = 0.79 vs. 0.77 and U = 0.16 vs. 0.14). Body mass index (BMI) was significantly associated with chest wall pain (p = 0.008). On multivariable analysis, mEUD and BMI remained significant predictors of chest wall pain (p = 0.0003 and 0.03, respectively). Conclusion: mEUD with moderate weighting better predicted chest wall pain than did V30, indicating that a small chest wall volume receiving a high radiation dose is responsible for chest wall pain. Independently of dose to the chest wall, BMI also correlated with chest wall pain.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance evaluation of CMIP6 models on the Arctic-Siberian Plain teleconnection affecting the East Asian heat waves

The frequency and intensity of summer heat waves in East Asia have increased sharply in recent decades, significantly impacting public health and the economy. The Arctic-Siberian Plain (ASP) teleconnection pattern has been identified as a key driver, with ASP warming amplifying atmospheric circulation patterns conducive to extreme temperatures. This study evaluates the ability of Coupled Model Inter-comparison Project phase 6 models to simulate the ASP pattern across interannual variability (IAV) and intra-seasonal variability (ISV) timescales using the Common Basis Function method. The multi-model mean shows statistically significant pattern correlations with ERA5 reanalysis, with correlation coefficients of 0.90 and 0.99 for IAV and ISV, respectively. While the ASP pattern is generally well captured, models exhibit substantial inter-model diversity in the intensity and position of anticyclonic anomalies over the ASP and East Asia. Models with ASP pattern variability similar to reanalysis better reproduce extreme East Asian temperatures, whereas those over- or underestimating ASP variability exhibit lower skill. These performance differences are related to differences in simulating key variables associated with the development of the ASP pattern. Our findings highlight the role of the ASP pattern in modulating extreme heat events, as models with improved ASP simulations align more closely with observed temperature extremes. Refining ASP representations in models could enhance seasonal heat wave predictions, improving climate adaptation strategies.

Arctic-Siberian Plain (ASP)↗

Product fine-structure resolved photodissociation dynamics: The A band of H{sub 2}O

The photodissociation dynamics of H{sub 2}O in its first absorption band is investigated on an accurate potential energy surface based on a large number of high-level ab initio points. Several ro-vibrational states of the parent molecule are considered. Different from most previous theoretical studies, the spin-orbit and Λ-doublet populations of the open-shell OH fragment are reported from full-dimensional wave packet calculations. The populations of the two spin-orbit manifolds are in most cases close to the statistical limit, but the Λ-doublet is dominated by the A{sup ″} component, thanks largely to the fast in-plane dissociation of H{sub 2}O(A{sup ~1}A{sup ′′}). Comparisons with experimental data and a Franck-Condon model are generally very good, although some discrepancies exist.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Determining pseudoscalar meson photoproduction amplitudes from complete experiments

In preparation for a new generation of complete experiments with the goal of performing a high precision extraction of pseudoscalar meson photo-production amplitudes, we present expressions that allow the direct numerical calculation of matrix elements with arbitrary spin projections from Chew-Goldberger-Low-Nambu (CGLN) amplitudes. We use this numerical tool to verify the most general analytic form of the cross section, dependent upon the three polarization vectors of the beam, target and recoil baryon, including all single, double and triple-polarization terms involving 16 spin-dependent observables. Analytic expressions that determine the recoil baryon polarization are presented, together with examples of their potential use with quasi-4? detectors to deduce observables. We assemble the analytic equations relating the 16 experimental observables and the CGLN amplitudes and use our independent method of numerical evaluation to resolve sign differences that exist in the literature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determining the tilt of the Raman laser beam using an optical method for atom gravimeters

The tilt of a Raman laser beam is a major systematic error in precision gravity measurement using atom interferometry. The conventional approach to evaluating this tilt error involves modulating the direction of the Raman laser beam and conducting time-consuming gravity measurements to identify the error minimum. In this work, we demonstrate a method to expediently determine the tilt of the Raman laser beam by transforming the tilt angle measurement into characterization of parallelism, which integrates the optical method of aligning the laser direction, commonly used in freely falling corner-cube gravimeters, into an atom gravimeter. A position-sensing detector (PSD) is utilized to quantitatively characterize the parallelism between the test beam and the reference beam, thus measuring the tilt precisely and rapidly. After carefully positioning the PSD and calibrating the relationship between the distance measured by the PSD and the tilt angle measured by the tiltmeter, we achieved a statistical uncertainty of less than 30 µrad in the tilt measurement. Furthermore, we compared the results obtained through this optical method with those from the conventional tilt modulation method for gravity measurement. The comparison validates that our optical method can achieve tilt determination with an accuracy level of better than 200 µrad, corresponding to a systematic error of 20 µGal in g measurement. This work has practical implications for real-world applications of atom gravimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The study of C-13(a, n)O-16 reactions in the Majorana Demonstrator calibration data

Neutron captures and delayed decays of reaction products are common sources of backgrounds in ultra-rare event searches. In this work, we studied 13C(a, n)1640 O reactions induced by a-particles emitted within the calibration sources of the Majorana Demonstrator. These sources are thorium-based calibration standards enclosed in carbon-rich materials. The reaction rate was estimated by using the 6129 keV ?-rays emitted from the excited 1643 O states that are populated when the incoming a-particles have enough energy. Thanks to the excellent energy performance of the Demonstrator’s germanium detectors, these characteristic photons can be clearly observed in the calibration data. Facilitated by Geant4 simulations, a comparison between the observed 6129 keV photon rates and predictions by a TALYS-based software was performed. The measurements and predictions were found to be consistent with each other, albeit with large statistical uncertainties. This agreement provides supports for further background predictions for (a, n)-reactions in future double-beta decay search efforts.

6 ≤ A ≤ 19↗

Computer-aided detection of breast masses: Four-view strategy for screening mammography

Purpose: To improve the performance of a computer-aided detection (CAD) system for mass detection by using four-view information in screening mammography. Methods: The authors developed a four-view CAD system that emulates radiologists' reading by using the craniocaudal and mediolateral oblique views of the ipsilateral breast to reduce false positives (FPs) and the corresponding views of the contralateral breast to detect asymmetry. The CAD system consists of four major components: (1) Initial detection of breast masses on individual views, (2) information fusion of the ipsilateral views of the breast (referred to as two-view analysis), (3) information fusion of the corresponding views of the contralateral breast (referred to as bilateral analysis), and (4) fusion of the four-view information with a decision tree. The authors collected two data sets for training and testing of the CAD system: A mass set containing 389 patients with 389 biopsy-proven masses and a normal set containing 200 normal subjects. All cases had four-view mammograms. The true locations of the masses on the mammograms were identified by an experienced MQSA radiologist. The authors randomly divided the mass set into two independent sets for cross validation training and testing. The overall test performance was assessed by averaging the free response receiver operating characteristic (FROC) curves of the two test subsets. The FP rates during the FROC analysis were estimated by using the normal set only. The jackknife free-response ROC (JAFROC) method was used to estimate the statistical significance of the difference between the test FROC curves obtained with the single-view and the four-view CAD systems. Results: Using the single-view CAD system, the breast-based test sensitivities were 58% and 77% at the FP rates of 0.5 and 1.0 per image, respectively. With the four-view CAD system, the breast-based test sensitivities were improved to 76% and 87% at the corresponding FP rates, respectively. The improvement was found to be statistically significant (p<0.0001) by JAFROC analysis. Conclusions: The four-view information fusion approach that emulates radiologists' reading strategy significantly improves the performance of breast mass detection of the CAD system in comparison with the single-view approach.

60 APPLIED LIFE SCIENCES↗

Technical Report: Reference photon dosimetry data for Varian accelerators based on IROC-Houston site visit data

Purpose: Accurate data regarding linear accelerator (Linac) radiation characteristics are important for treatment planning system modeling as well as regular quality assurance of the machine. The Imaging and Radiation Oncology Core-Houston (IROC-H) has measured the dosimetric characteristics of numerous machines through their on-site dosimetry review protocols. Photon data are presented and can be used as a secondary check of acquired values, as a means to verify commissioning a new machine, or in preparation for an IROC-H site visit. Methods: Photon data from IROC-H on-site reviews from 2000 to 2014 were compiled and analyzed. Specifically, data from approximately 500 Varian machines were analyzed. Each dataset consisted of point measurements of several dosimetric parameters at various locations in a water phantom to assess the percentage depth dose, jaw output factors, multileaf collimator small field output factors, off-axis factors, and wedge factors. The data were analyzed by energy and parameter, with similarly performing machine models being assimilated into classes. Common statistical metrics are presented for each machine class. Measurement data were compared against other reference data where applicable. Results: Distributions of the parameter data were shown to be robust and derive from a student’s t distribution. Based on statistical and clinical criteria, all machine models were able to be classified into two or three classes for each energy, except for 6 MV for which there were eight classes. Quantitative analysis of the measurements for 6, 10, 15, and 18 MV photon beams is presented for each parameter; supplementary material has also been made available which contains further statistical information. Conclusions: IROC-H has collected numerous data on Varian Linacs and the results of photon measurements from the past 15 years are presented. The data can be used as a comparison check of a physicist’s acquired values. Acquired values that are well outside the expected distribution should be verified by the physicist to identify whether the measurements are valid. Comparison of values to this reference data provides a redundant check to help prevent gross dosimetric treatment errors.

60 APPLIED LIFE SCIENCES↗

Evaluation of sliding baseline methods for spatial estimation for cluster detection in the biosurveillance system

Background: The Centers for Disease Control and Prevention's (CDC's) BioSense system provides near-real time situational awareness for public health monitoring through analysis of electronic health data. Determination of anomalous spatial and temporal disease clusters is a crucial part of the daily disease monitoring task. Our study focused on finding useful anomalies at manageable alert rates according to available BioSense data history. Methods: The study dataset included more than 3 years of daily counts of military outpatient clinic visits for respiratory and rash syndrome groupings. We applied four spatial estimation methods in implementations of space-time scan statistics cross-checked in Matlab and C. We compared the utility of these methods according to the resultant background cluster rate (a false alarm surrogate) and sensitivity to injected cluster signals. The comparison runs used a spatial resolution based on the facility zip code in the patient record and a finer resolution based on the residence zip code. Results: Simple estimation methods that account for day-of-week (DOW) data patterns yielded a clear advantage both in background cluster rate and in signal sensitivity. A 28-day baseline gave the most robust results for this estimation; the preferred baseline is long enough to remove daily fluctuations but short enough to reflect recent disease trends and data representation. Background cluster rates were lower for the rash syndrome counts than for the respiratory counts, likely because of seasonality and the large scale of the respiratory counts. Conclusion: The spatial estimation method should be chosen according to characteristics of the selected data streams. In this dataset with strong day-of-week effects, the overall best detection performance was achieved using subregion averages over a 28-day baseline stratified by weekday or weekend/holiday behavior. Changing the estimation method for particular scenarios involving different spatial resolution or other syndromes can yield further improvement.

59 BASIC BIOLOGICAL SCIENCES↗

Impact of model improvements on 80 m wind speeds during the second Wind Forecast Improvement Project (WFIP2)

Abstract. During the second Wind Forecast Improvement Project (WFIP2; October 2015–March 2017, held in the Columbia River Gorge and Basin area of eastern Washington and Oregon states), several improvements to the parameterizations used in the High Resolution Rapid Refresh (HRRR – 3 km horizontal grid spacing) and the High Resolution Rapid Refresh Nest (HRRRNEST – 750 m horizontal grid spacing) numerical weather prediction (NWP) models were tested during four 6-week reforecast periods (one for each season). For these tests the models were run in control (CNT) and experimental (EXP) configurations, with the EXP configuration including all the improved parameterizations. The impacts of the experimental parameterizations on the forecast of 80 m wind speeds (wind turbine hub height) from the HRRR and HRRRNEST models are assessed, using observations collected by 19 sodars and three profiling lidars for comparison. Improvements due to the experimental physics (EXP vs. CNT runs) and those due to finer horizontal grid spacing (HRRRNEST vs. HRRR) and the combination of the two are compared, using standard bulk statistics such as mean absolute error (MAE) and mean bias error (bias). On average, the HRRR 80 m wind speed MAE is reduced by 3 %–4 % due to the experimental physics. The impact of the finer horizontal grid spacing in the CNT runs also shows a positive improvement of 5 % on MAE, which is particularly large at nighttime and during the morning transition. Lastly, the combined impact of the experimental physics and finer horizontal grid spacing produces larger improvements in the 80 m wind speed MAE, up to 7 %–8 %. The improvements are evaluated as a function of the model's initialization time, forecast horizon, time of the day, season of the year, site elevation, and meteorological phenomena. Causes of model weaknesses are identified. Finally, bias correction methods are applied to the 80 m wind speed model outputs to measure their impact on the improvements due to the removal of the systematic component of the errors.

17 WIND ENERGY↗

An experimental verification of laser-velocimeter sampling bias and its correction

The existence of 'sampling bias' in individual-realization laser velocimeter measurements is experimentally verified and shown to be independent of sample rate. The experiments were performed in a simple two-stream mixing shear flow with the standard for comparison being laser-velocimeter results obtained under continuous-wave conditions. It is also demonstrated that the errors resulting from sampling bias can be removed by a proper interpretation of the sampling statistics. In addition, data obtained in a shock-induced separated flow and in the near-wake of airfoils are presented, both bias-corrected and uncorrected, to illustrate the effects of sampling bias in the extreme.

Johnson, D. A.↗

Statistical analysis of turbulence data from the NASA Marshall Space Flight Center atmospheric boundary layer tower array facility

Statistical properties of atmospheric turbulence near the Earth's surface are presented. Emphasis is placed on the probability density distribution two point spatial correlation, length scale, and two point and single point spectrum. Comparison of the data with isotropic homogeneous models is made. In general, agreement with the models is poor. For the design of aircraft during operations in the lower levels associated with approach, takeoff, and terrain following, it appears necessary to improve existing models or develop new nonisotropic turbulence models.

Frost, W.↗

Three-dimensional analysis of magnetometer array data

A technique is developed for mapping magnetic variation fields in three dimensions using data from an array of magnetometers, based on the theory of optimal linear estimation. The technique is applied to data from the Scandinavian Magnetometer Array. Estimates of the spatial power spectra for the internal and external magnetic variations are derived, which in turn provide estimates of the spatial autocorrelation functions of the three magnetic variation components. Statistical errors involved in mapping the external and internal fields are quantified and displayed over the mapping region. Examples of field mapping and of separation into external and internal components are presented. A comparison between the three-dimensional field separation and a two-dimensional separation from a single chain of stations shows that significant differences can arise in the inferred internal component.

Richmond, A. D.↗

A review of near-wall Reynolds-stress

The advances made in second-order near-wall turbulence closures are summarized. All closures examined are based on some form of high Reynolds number models for the Reynolds stress and the turbulent kinetic energy dissipation rate equations. Consequently, most near-wall closures proposed to data attempt to modify the high Reynolds number models for the dissipation rate equation so that the resultant models are applicable all the way to the wall. The near-wall closures are examined for their asymptotic behavior so that they can be compared with the proper near-wall behavior of the exact equations. A comparison of the closure's performance in the calculation of a low Reynolds number plane channel flow is carried out. In addition, the closures are evaluated for their ability to predict the turbulence statistics and the limiting behavior of the structure parameters compared to direct simulation data.

So, R. M. C.↗

Stochastic estimation of coherent structures in turbulent boundary layers

The stochastic estimation technique is described as well as its extension to two-point and space-time conditional estimates. Based on the experimental data of Guezennec (1985), a comparison is made between the stochastic estimates and the conventional ensemble averaging results. As only the normal velocity and streamwise components were measured at each point on the sampling grid, the assumption of statistical symmetry in the spanwise direction about the centerline was used and the spanwise velocity component was reconstructed by integrating the continuity equation from the centerline outward.

Guezennec, Y. G.↗

A rule-based software test data generator

Rule-based software test data generation is proposed as an alternative to either path/predicate analysis or random data generation. A prototype rule-based test data generator for Ada programs is constructed and compared to a random test data generator. Four Ada procedures are used in the comparison. Approximately 2000 rule-based test cases and 100,000 randomly generated test cases are automatically generated and executed. The success of the two methods is compared using standard coverage metrics. Simple statistical tests showing that even the primitive rule-based test data generation prototype is significantly better than random data generation are performed. This result demonstrates that rule-based test data generation is feasible and shows great promise in assisting test engineers, especially when the rule base is developed further.

Deason, William H.↗

BATSE gamma-ray burst line search. 2: Bayesian consistency methodology

We describe a Bayesian methodology to evaluate the consistency between the reported Ginga and Burst and Transient Source Experiment (BATSE) detections of absorption features in gamma-ray burst spectra. Currently no features have been detected by BATSE, but this methodology will still be applicable if and when such features are discovered. The Bayesian methodology permits the comparison of hypotheses regarding the two detectors' observations and makes explicit the subjective aspects of our analysis (e.g., the quantification of our confidence in detector performance). We also present non-Bayesian consistency statistics. Based on preliminary calculations of line detectability, we find that both the Bayesian and non-Bayesian techniques show that the BATSE and Ginga observations are consistent given our understanding of these detectors.

Band, D. L.↗