Holographic entanglement distillation from the surface state correspondence

We study correlations between geometric subfactors living on the Ryu-Takayanagi surface that bounds the entanglement wedge. Using the surface-state correspondence and the bit threads program, we are able to calculate mutual information and conditional mutual information between subfactors. This enables us to count the shared Bell pairs between subfactors, and we propose an entanglement distillation procedure over these subsystems via a SWAP gate protocol. We comment on extending to multipartite entanglement.

99 GENERAL AND MISCELLANEOUS↗

A comparative study between real-world and laboratory accelerated aging of Cu/SSZ-13 SCR catalysts

Elucidating aging mechanisms in real-world applications is a critical component for developing and maintaining Cu/SSZ-13 SCR catalysts. To reveal gaps between laboratory accelerated aging and real-world aging, herein we report thorough comparative studies between 6 representative catalysts. Here, we apply a wide range of catalyst characterization methods, including surface area/porosity analysis, X-ray diffraction (XRD), H 2 -temperature programmed reduction, NH3-temperaure programmed desorption, solid-state nuclear magnetic resonance (NMR), in situ X-ray photoelectron (XPS) and electron paramagnetic resonance (EPR) spectroscopies, to gain atomic-level knowledge on Cu transformation under different aging protocols. We then correlate such knowledge to SCR, NH 3 /NO oxidation kinetic behavior of the catalysts. We found that sulfur aging plays the most important role in interpreting catalyst degradation during real-world application, including direct sulfur poisoning of isolated Cu II SCR active species to CuSO 4 -like species, the agglomeration of such species to multinuclear CuSO 4 clusters, and eventually, CuO formation during desulfation treatments. Such chemistries convert SCR active Cu to SCR inert Cu moieties without severely deteriorating catalyst support integrity. These characteristics are partially replicated by hydrothermal aging in the presence of SOx but are poorly mimicked by hydrothermal aging alone.

36 MATERIALS SCIENCE↗

Expression, purification, characterization and crystallization of non- and phosphorylated states of JAK2 and JAK3 kinase domain

Janus-associated kinases (JAKs) play critical roles in cytokine signaling, and have emerged as viable therapeutic targets in inflammation and oncology related diseases. To date, targeting JAK proteins with highly selective inhibitor compounds have remained elusive. We have expressed the active kinase domains for both JAK2 and JAK3 and devised purification protocols to resolve the non-, mono- (Y1007) and diphosphorylated (Y1007 and Y1008) states of JAK2 and non- and monophosphorylated states of JAK3 (Y980). An optimal purified protein yield of 20, 29 and 69 mg per 20 L cell culture was obtained for the three JAK2 forms, respectively, and 12.2 and 2.3 mg per 10 L fermentation for the two JAK3 forms allowing detailed biochemical and biophysical studies. To monitor the purification process we developed a novel HPLC activity assay where a sequential order of phosphorylation was observed whereby the first tyrosine residue was completely phosphorylated prior to phosphorylation of the tandem tyrosine residue. A Caliper-based microfluidics assay was used to determine the kinetic parameters (K{sub m} and k{sub cat}) for each phosphorylated state, showing that monophosphorylated (Y1007) JAK2 enzyme activity increased 9-fold over that of the nonphosphorylated species, and increased an additional 6-fold for the diphosphorylated (Y1007/Y1008) species, while phosphorylation of JAK3 resulted in a negligible increase in activity. Moreover, crystal structures have been generated for each isolated state of JAK2 and JAK3 with resolutions better than 2.4 {angstrom}. The generation of these reagents has enabled kinetic and structural characterization to inform the design of potent and selective inhibitors of the JAK family.

59 BASIC BIOLOGICAL SCIENCES↗

Assessment of TMT Labeling Efficiency in Large-Scale Quantitative Proteomics: The Critical Effect of Sample pH

Isobaric labeling via tandem mass tag (TMT) reagents enables sample multiplexing prior to LC–MS/MS, facilitating high-throughput large-scale quantitative proteomics. Consistent and efficient labeling reactions are essential to achieve robust quantification; therefore, embedded in our clinical proteomic protocol is a quality control (QC) sample that contains a small aliquot from each sample within a TMT set, referred to as “Mixing QC.” This Mixing QC enables the detection of TMT labeling issues by LC–MS/MS before combining the full samples to allow for salvaging of poor TMT labeling reactions. While TMT labeling is a valuable tool, factors leading to poor reactions are not fully studied. We observed that relabeling does not necessarily rescue TMT reactions and that peptide samples sometimes remained acidic after resuspending in 50 mM HEPES buffer (pH 8.5), which coincided with low labeling efficiency (LE) and relatively low median reporter ion intensities (MRIIs). To obtain a more resilient TMT labeling procedure, we investigated LE, reporter ion missingness, the ratio of mean TMT set MRII to individual channel MRII, and the distribution of log 2 reporter ion ratios of Mixing QC samples. We discovered that sample pH is a critical factor in LE, and increasing the buffer concentration in poorly labeled samples before relabeling resulted in the successful rescue of TMT labeling reactions. Moreover, resuspending peptides in 500 mM HEPES buffer for TMT labeling resulted in consistently higher LE and lower missing data. By better controlling the sample pH for labeling and implementing multiple methods for assessing labeling quality before combining samples, we demonstrate that robust TMT labeling for large-scale quantitative studies is achievable.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Globus service enhancements for exascale applications and facilities

Many extreme-scale applications require the movement of large quantities of data to, from, and among leadership computing facilities, as well as other scientific facilities and the home institutions of facility users. These applications, particularly when leadership computing facilities are involved, can touch upon edge cases (e.g., terabyte files) that had not been a focus of previous Globus optimization work, which had emphasized rather the movement of many smaller (megabyte to gigabyte) files. We report here on how automated client-driven chunking can be used to accelerate both the movement of large files and the integrity checking operations that have proven to be essential for large data transfers. In conclusion, we present detailed performance studies that provide insights into the benefits of these modifications in a range of file transfer scenarios.

97 MATHEMATICS AND COMPUTING↗

Development of a Mine Rescue Drilling System (MRDS)

Sandia National Laboratories (Sandia) has a long history in developing compact, mobile, very high-speed drilling systems and this technology could be applied to increasing the rate at which boreholes are drilled during a mine accident response. The present study reviews current technical approaches, primarily based on technology developed under other programs, analyzes mine rescue specific requirements to develop a conceptual mine rescue drilling approach, and finally, proposes development of a phased mine rescue drilling system (MRDS) that accomplishes (1) development of rapid drilling MRDS equipment; (2) structuring improved web communication through the Mine Safety & Health Administration (MSHA) web site; (3) development of an improved protocol for employment of existing drilling technology in emergencies; (4) deployment of advanced technologies to complement mine rescue drilling operations during emergency events; and (5) preliminary discussion of potential future technology development of specialized MRDS equipment. This phased approach allows for rapid fielding of a basic system for improved rescue drilling, with the ability to improve the system over time at a reasonable cost.

42 ENGINEERING↗

Ion chamber absorbed dose calibration coefficients, N{sub D,w}, measured at ADCLs: Distribution analysis and stability

Purpose: To analyze absorbed dose calibration coefficients, N{sub D,w}, measured at accredited dosimetry calibration laboratories (ADCLs) for client ionization chambers to study (i) variability among N{sub D,w} coefficients for chambers of the same type calibrated at each ADCL to investigate ion chamber volume fluctuations and chamber manufacturing tolerances; (ii) equivalency of ion chamber calibration coefficients measured at different ADCLs by intercomparing N{sub D,w} coefficients for chambers of the same type; and (iii) the long-term stability of N{sub D,w} coefficients for different chamber types by investigating repeated chamber calibrations. Methods: Large samples of N{sub D,w} coefficients for several chamber types measured over the time period between 1998 and 2014 were obtained from the three ADCLs operating in the United States. These are analyzed using various graphical and numerical statistical tests for the four chamber types with the largest samples of calibration coefficients to investigate (i) and (ii) above. Ratios of calibration coefficients for the same chamber, typically obtained two years apart, are calculated to investigate (iii) above and chambers with standard deviations of old/new ratios less than 0.3% meet stability requirements for accurate reference dosimetry recommended in dosimetry protocols. Results: It is found that N{sub D,w} coefficients for a given chamber type compared among different ADCLs may arise from differing probability distributions potentially due to slight differences in calibration procedures and/or the transfer of the primary standard. However, average N{sub D,w} coefficients from different ADCLs for given chamber types are very close with percent differences generally less than 0.2% for Farmer-type chambers and are well within reported uncertainties. Conclusions: The close agreement among calibrations performed at different ADCLs reaffirms the Calibration Laboratory Accreditation Subcommittee process of ensuring ADCL conformance with National Institute of Standards and Technology standards. This study shows that N{sub D,w} coefficients measured at different ADCLs are statistically equivalent, especially considering reasonable uncertainties. This analysis of N{sub D,w} coefficients also allows identification of chamber types that can be considered stable enough for accurate reference dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

Scaling open-weight large language models for hydropower regulatory information extraction: A systematic analysis

Information extraction from regulatory and technical documents using large language models (LLMs) involves practical trade-offs between extraction quality and computational cost. We evaluate eight open-weight LLMs spanning 0.6B–70B parameters on hydropower licensing documents and report deployment-oriented evidence under a unified extraction schema and evaluation protocol. Across the model set, we observe clear scale-dependent trends in both baseline extraction quality and the effectiveness of reflective reasoning (self-checking) under our fixed-prompt, no-augmentation setting. Mid-scale models often provide a favorable balance of accuracy and efficiency, whereas the smallest models show limited or inconsistent gains from the reasoning variants tested. Larger models achieve the highest overall F1 scores but incur substantially greater compute and infrastructure requirements. We further find that reliability failure modes can distort conventional metrics in this domain: in particular, high recall can coincide with systematic extraction errors when models fabricate values for fields that are absent from the source text, underscoring the importance of conservative null handling and evidence-grounded evaluation. Overall, our study provides a reproducible resource–performance comparison for open-weight LLM-based extraction in hydropower regulatory documentation and offers practical guidance for model selection under different deployment constraints.

Evaluation protocol↗

SU-E-T-370: Evaluating Plan Quality and Dose Delivery Accuracy of Tomotherapy SBRT Treatments for Lung Cancer

Purpose: This study evaluated the plan quality and dose delivery accuracy of stereotactic body radiotherapy (SBRT) helical Tomotherapy (HT) treatments for lung cancer. Results were compared with those previously reported by our group for flattening filter (FF) and flattening filter free (FFF) VMAT treatments. This work forms part of an ongoing multicentre and multisystem planning and dosimetry audit on FFF beams for lung SBRT. Methods: CT datasets and DICOM RT structures delineating the target volume and organs at risk for 6 lung cancer patients were selected. Treatment plans were generated using the HT treatment planning system. Tumour locations were classified as near rib, near bronchial tree or in free lung with prescribed doses of 48Gy/4fr, 50Gy/5fr and 54Gy/3fr respectively. Dose constraints were specified by a modified RTOG0915 protocol used for an Australian SBRT phase II trial. Plan quality was evaluated using mean PTV dose, PTV volume receiving 100% of the prescribed dose (V100%), target conformity (CI=VD100%/VPTV) and low dose spillage (LDS=VD50%/VPTV). Planned dose distributions were compared to those measured using an ArcCheck phantom. Delivery accuracy was evaluated using a gamma-index pass rate of 95% with 3% (of max dose) and 3mm criteria. Results: Treatment plans for all patients were clinically acceptable in terms of quality and accuracy of dose delivery. The following DVH metrics are reported as averages (SD) of all plans investigated: mean PTV dose was 115.3(2.4)% of prescription, V100% was 98.8(0.9)%, CI was 1.14(0.03) and LDS was 5.02(0.37). The plans had an average gamma-index passing rate of 99.3(1.3)%. Conclusion: The results reported in this study for HT agree within 1 SD to those previously published by our group for VMAT FF and FFF lung SBRT treatments. This suggests that HT delivers lung SBRT treatments of comparable quality and delivery accuracy as VMAT using both FF and FFF beams.

60 APPLIED LIFE SCIENCES↗

Design and evaluation of the MAMMI dedicated breast PET

Purpose: A breast dedicated positron emission tomography (PET) scanner has been developed based on monolithic LYSO crystals coupled to position sensitive photomultiplier tubes (PSPMTs). In this study, we describe the design of the PET system and report on its performance evaluation. Methods: MAMMI is a breast PET scanner based on monolithic LYSO crystals. It consists of 12 compact modules with a transaxial field of view (FOV) of 170 mm in diameter and 40 mm axial FOV that translates to cover up to 170 mm. The patient lies down in a prone position that facilitates maximum breast elongation. Quantitative performance analysis of the calculated method for the attenuation correction specifically developed for MAMMI, and based on PET image segmentation, has also been conducted in this evaluation. In order to fully determine the MAMMI prototype's performance, we have adapted the measurements suggested for National Electrical Manufacturers Association (NEMA) NU 2-2007 and NU 4-2008 protocol tests, as they are defined for whole-body and small animal PET scanners, respectively. Results: Spatial resolutions of 1.6, 1.8, and 1.9 mm were measured in the axial, radial, and tangential directions, respectively. A scatter fraction of 20.8% was obtained and the maximum NEC was determined to be 25 kcps at 44 MBq. The average sensitivity of the system was observed to be 1% for an energy window of (250 keV-750 keV) and a maximum absolute sensitivity of 1.8% was measured at the FOV center. Conclusions: The overall performance of the MAMMI reported on this evaluation quantifies its ability to produce high quality PET images. Spatial resolution values below 3 mm were measured in most of the FOV. Only the radial component of spatial resolution exceeds the 3 mm at radial positions larger than 60 mm. This study emphasizes the need for standardized testing methodologies for dedicated breast PET systems similar to NEMA standards for whole-body and small animal PET scanners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rapid and high-throughput determination of sorghum ( Sorghum bicolor ) biomass composition using near infrared spectroscopy and chemometrics

Compositional characterization of biomass is vital for the biofuel industry. Traditional wet chemistry-based methods for analyzing biomass composition are laborious, time-consuming, and require extensive use of chemical reagents as well as highly skilled personnel. In this study, near-infrared (NIR) spectroscopy was used to quickly assess the composition of above-ground vegetative biomass from 113 diverse, photoperiod-sensitive, biomass-type sorghum (Sorghum bicolor) accessions cultivated under field conditions in Central Illinois. Biomass samples were analyzed using NIR spectra collected in the spectral range of 867–2536 nm, with their chemical compositions determined following the National Renewable Energy Laboratory (NREL) protocol. Advanced spectral pre-treatment and band selection techniques were utilized to develop calibration models using partial least squares regression (PLSR). The models’ effectiveness was assessed through cross-validation and independent data tests. The predictions for moisture, ash, extractives, glucan, xylan, acid-soluble lignin (ASL), acid-insoluble lignin (AIL), and total lignin were accurate and reliable, demonstrating the capability of NIR spectroscopy to provide rapid and precise characterization of sorghum biomass. The results demonstrated that NIR spectroscopy is an efficient tool for rapidly characterizing sorghum biomass, making it a sustainable option for screening desirable feedstock for biofuel or bioproduct production.

09 BIOMASS FUELS↗

An assessment of the long-term persistence of prion infectivity in aquatic environments

The environment plays a key role in horizontal transmission of prion diseases, since prions are extremely resistant to classical inactivation procedures. In prior work, we observed the high stability of bovine spongiform encephalopathy (BSE) infectivity when these prions were incubated in aqueous media such as phosphate-buffered saline (PBS) or wastewater for nearly nine months. As a continuation of this experiment, the same samples were maintained in PBS or wastewater for five additional years and residual BSE infectivity was assessed in bovine PrP{sup C} transgenic mice. Over this long time period (more than six years), BSE infectivity was reduced by three and one orders of magnitude in wastewater and PBS respectively. To rule out a possible agent specific effect, sheep scrapie prions were subjected to the same experimental protocol, using eight years as the experimental end-point. No significant reduction in scrapie infectivity was observed over the first nine months of wastewater incubation while PBS incubation for eight years only produced a two logarithmic unit reduction in infectivity. By contrast, the dynamics of PrP{sup Res} persistence was different, disappearing progressively over the first year. The long persistence of prion infectivity observed in this study for two different agents provides supporting evidence of the assumed high stability of these agents in aquatic environments and that environmental processes or conventional wastewater treatments with low retention times would have little impact on prion infectivity. These results could have great repercussions in terms of risk assessment and safety for animals and human populations. - Highlights: • Prion infectivity resists long term incubations in aquatic environments. • Infectivity persistence in wastewater is reduced when compared to PBS. • In this study PrPRes fails as a marker for prion detection. • Mice bioassay is the most powerful tool for assessing prion presence. • Wastewater conventional treatment would not eliminate prion infectivity.

54 ENVIRONMENTAL SCIENCES↗

Identifying Patients Who Are Unsuitable for Accelerated Partial Breast Irradiation Using Three-dimensional External Beam Conformal Techniques

Purpose: Several recent studies reported that severe late toxicities including soft-tissue fibrosis and fat necrosis are present in patients treated with accelerated partial breast irradiation (APBI) and that these toxicities are associated with the large volume of tissue targeted by high-dose irradiation. The present study was performed to clarify which patients are unsuitable for APBI to avoid late severe toxicities. Methods and Materials: Study subjects comprised 50 consecutive patients with Stage 0-II unilateral breast cancer who underwent breast-conserving surgery, and in whom five or six surgical clips were placed during surgery. All patients were subsequently replanned using three-dimensional conformal radiotherapy (3D-CRT) APBI techniques according to the National Surgical Adjuvant Breast and Bowel Project (NSABP) B-39 and Radiation Therapy Oncology Group (RTOG) 0413 protocol. The beam arrangements included mainly noncoplanar four- or five-field beams using 6-MV photons alone. Results: Dose-volume histogram (DVH) constraints for normal tissues according to the NSABP/RTOG protocol were satisfied in 39 patients (78%). Multivariate analysis revealed that only long craniocaudal clip distance (CCD) was correlated with nonoptimal DVH constraints (p = 0.02), but that pathological T stage, anteroposterior clip distance (APD), site of ipsilateral breast (IB) (right/left), location of the tumor (medial/lateral), and IB reference volume were not. DVH constraints were satisfied in 20% of patients with a long CCD ({>=}5.5 cm) and 92% of those with a short CCD (p < 0.0001). Median IB reference volume receiving {>=}50% of the prescribed dose (IB-V{sub 50}) of all patients was 49.0% (range, 31.4-68.6). Multivariate analysis revealed that only a long CCD was correlated with large IB-V{sub 50} (p < 0.0001), but other factors were not. Conclusion: Patients with long CCDs ({>=}5.5 cm) might be unsuitable for 3D-CRT APBI because of nonoptimal DVH constraints and large IB-V{sub 50}.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Stepwise "Micellization-Crystallization" Route to Oblate Ellipsoidal, Cylindrical, and Bilayer Micelles with Polyethylene Cores in Water

Micellar polymorphism from block copolymers has been well documented, but most attention has focused on noncrystalline hydrophobic systems. We have investigated the micellization in water of model diblock copolymers with semicrystalline polyethylene (PE) as the core-forming component. Poly(N,N-dimethylacrylamide)–polyethylene (AE) diblock copolymers were synthesized by a combination of anionic and RAFT polymerizations. The bulk nanostructures were probed by small-angle X-ray scattering (SAXS) and AE diblock copolymers were found to be moderately segregated at 140 °C. Dispersions of AE amphiphiles in water were prepared by direct dissolution at 120 °C (i.e., above the melting transition of PE) followed by cooling to 25 °C. By manipulating the composition of AE diblock copolymers, discrete structures with oblate ellipsoidal, cylindrical, and bilayer morphologies were produced, as evidenced in cryogenic transmission electron microscopy (cryo-TEM). The self-assembled aggregates were also studied by small-angle neutron scattering (SANS) and dilute solution rheology. The semicrystalline nature of the nanostructures was further revealed by differential scanning calorimetry (DSC) and wide-angle X-ray scattering (WAXS). A stepwise “micellization–crystallization” process was proposed as the micelle formation mechanism, as supported by the existence of similar nanostructures at 120 °C using SANS. This strategy holds promise for a general protocol toward the production of giant wormlike micelles and vesicles with semicrystalline polymeric cores.

Yin, Ligeng↗

Sub 20 cm -1 computational prediction of the CH bond energy – a case of systematic error in computational thermochemistry

Here, the bond dissociation energy of methylidyne, D 0 (CH), is studied using an improved version of the High-Accuracy Extrapolated ab initio Thermochemistry (HEAT) approach as well as the Feller–Peterson–Dixon (FPD) model chemistry. These calculations, which include basis sets up to nonuple (aug-cc-pCV9Z) quality, are expected to be capable of providing results substantially more accurate than the ca. 1 kJ mol -1 level that is characteristic of standard high-accuracy protocols for computational thermochemistry. The calculated 0 K CH bond energy (27 954 ± 15 cm -1 for HEAT and 27 956 ± 15 cm -1 for FPD), along with equivalent treatments of the CH ionization energy and the CH + dissociation energy (85 829 ± 15 cm -1 and 32 946 ± 15 cm -1 , respectively), were compared to the existing benchmarks from Active Thermochemical Tables (ATcT), uncovering an unexpected difference for D 0 (CH). This has prompted a detailed reexamination of the provenance of the corresponding ATcT benchmark, allowing the discovery and subsequent correction of a systematic error present in several published high-level calculations, ultimately yielding an amended ATcT benchmark for D 0 (CH). Finally, the current theoretical results were added to the ATcT Thermochemical Network, producing refined ATcT estimates of 27 957.3 ± 6.0 cm -1 for D0(CH), 32 946.7 ± 0.6 cm -1 for D 0 (CH + ), and 85 831.0 ± 6.0 cm -1 for IE(CH).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN↗

Reflections on one million compounds in the open quantum materials database (OQMD)

Abstract Density functional theory (DFT) has been widely applied in modern materials discovery and many materials databases, including the open quantum materials database (OQMD), contain large collections of calculated DFT properties of experimentally known crystal structures and hypothetical predicted compounds. Since the beginning of the OQMD in late 2010, over one million compounds have now been calculated and stored in the database, which is constantly used by worldwide researchers in advancing materials studies. The growth of the OQMD depends on project-based high-throughput DFT calculations, including structure-based projects, property-based projects, and most recently, machine-learning-based projects. Another major goal of the OQMD is to ensure the openness of its materials data to the public and the OQMD developers are constantly working with other materials databases to reach a universal querying protocol in support of the FAIR data principles.

08 HYDROGEN↗

Neutral-atom entanglement using adiabatic Rydberg dressing

Here we revisit the implementation of a two-qubit entangling gate, the Mølmer-Sørensen gate, using the adiabatic Rydberg dressing paradigm for neutral atoms as studied in [A. Mitra et al., Phys. Rev. A 101, 030301(R) (2020)]. We study the implementation of rapid adiabatic passage using a two-photon transition, which does not require the use of an ultraviolet laser, and can be implemented using only amplitude modulation of one field with all laser frequencies fixed. We find that entangling gate fidelities, comparable to the one-photon excitation, are achievable with the two-photon excitation. Moreover, we address how the adiabatic dressing protocol can be used to implement entangling gates outside the regime of a perfect Rydberg blockade. We show that, by using adiabatic dressing, we can achieve scaling of the gate fidelity set by the fundamental limits to entanglement generated by the Rydberg interactions while simultaneously retaining a limited population in the doubly excited Rydberg state. This allows for fast high-fidelity gates for atoms separated beyond the blockade radius.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗