Search NASA⌕ Search

SEARCH · Search NASA

Results for “Accelerating cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Computational Science Research in Support of Petascale Electromagnetic Modeling

Computational science research components were vital parts of the SciDAC-1 accelerator project and are continuing to play a critical role in newly-funded SciDAC-2 accelerator project, the Community Petascale Project for Accelerator Science and Simulation (ComPASS). Recent advances and achievements in the area of computational science research in support of petascale electromagnetic modeling for accelerator design analysis are presented, which include shape determination of superconducting RF cavities, mesh-based multilevel preconditioner in solving highly-indefinite linear systems, moving window using h- or p- refinement for time-domain short-range wakefield calculations, and improved scalable application I/O.

43 PARTICLE ACCELERATORS↗

Slip-stacking Dynamics for High-Power Proton Beams at Fermilab

Slip-stacking is a particle accelerator configuration used to store two particle beams with different momenta in the same ring. The two beams are longitudinally focused by two radiofrequency (RF) cavities with a small frequency difference between them. Each beam is synchronized to one RF cavity and perturbed by the other RF cavity. Fermilab uses slip-stacking in the Recycler so as to double the power of the 120 GeV proton beam in the Main Injector. This dissertation investigates the dynamics of slip-stacking beams analytically, numerically and experimentally. In the analytic analysis, I find the general trajectory of stable slip-stacking particles and identify the slip-stacking parametric resonances. In the numerical analysis, I characterize the stable phase-space area and model the particle losses. In particular, I evaluate the impact of upgrading the Fermilab Booster cycle-rate from 15 Hz to 20 Hz as part of the Proton Improvement Plan II (PIP-II). The experimental analysis is used to verify my approach to simulating slip-stacking loss. I design a study for measuring losses from the longitudinal single-particle dynamics of slip-stacking as a function of RF cavity voltage and RF frequency separation. I further propose the installation of a harmonic RF cavity and study the dynamics of this novel slip-stacking configuration. I show the harmonic RF cavity cancels out parametric resonances in slip-stacking, reduces emittance growth during slip-stacking, and dramatically enhances the stable phase-space area. The harmonic cavity is expected to reduce slip-stacking losses to far exceed PIP-II requirements. These results raise the possibility of extending slip-stacking beyond the PIP-II era.

43 PARTICLE ACCELERATORS↗

Commissioning of SRF Cavity Analyzer System

Research and development in Superconducting Radio Frequency (SRF) cavities manufacturing, surface treatment, preparation, and doping techniques for the improvement of cavities performance necessitate reliable cavities’ intrinsic quality factor measurement with accurate and repeatable results. Fermilab Vertical Test Stand facility (VTS) performs ~270 cavities tests per year, including R&D cavities as well as production cavities at each step of their preparation for the placement in accelerator’s cryomodules. Current Fermilab VTS testing system is based on the scalar approach of power measurement, which neglects potential error factors of the RF networks with distributed parameters, hence the assessed measurement errors of such a system might be slightly underestimated. Alternative approach, utilizing a vector measurement (amplitude and phase) of RF signals in the setup with a cavity as a device under test, promises an enhanced accuracy and results traceability. New cavity an alyser system based on this approach (Vector VTS) was developed by D. Frolov et al. and currently undergoes a commissioning process. Basic underlying principles of the system will be presented with the methods of quality factor extraction from S-parameters measurement of multiport cavities and brief error analysis will be discussed. The system architecture will be shown with main components parameters and ensuing testing capabilities. Multiple tests results will be discussed with a cross-check comparison of the results obtained with a conventional testing method. System advantages such as automated calibration process and additional features as a built- in microphonics measurement capability will be presented.

Netepenko, A.↗

Status of the Short-Pulse X-ray Project (SPX) at the Advanced Photon Source (APS)

The Advanced Photon Source Upgrade project (APS-U) at Argonne includes implementation of Zholents’* deflecting cavity scheme for production of short x-ray pulses. This is a joint project between Argonne National Laboratory, Thomas Jefferson National Laboratory, and Lawrence Berkeley National Laboratory. This paper describes performance characteristics of the proposed source and technical issues related to its realization. Ensuring stable APS storage ring operation requires reducing quality factors of these modes by many orders of magnitude. These challenges reduce to those of the design of a single-cell SC cavity that can achieve the desired operating deflecting fields while providing needed damping of all these modes. The project team is currently prototyping and testing several promising designs for single-cell cavities with the goal of deciding on a winning design in the near future. Here

43 PARTICLE ACCELERATORS↗

Ingot Niobium RF Cavity Design and Development at BARC

This article presents the different activity of Ingot niobium in BARC. BARC is developing a technology for the accelerator driven subcritical system (ADSS) that will be mainly utilized for the transmutation of nuclear waste and enrichment of U{sup 233}. Design and development of superconducting medium velocity cavity has been taken up as a part of the ADSS project. The design and fabrication of f = 1050 MHz, {beta} = 0.49 with Ingot niobium will be presented. Positron annihilation studies are conducted on small samples of ingot niobium to understand the defect depth profile of the niobium surface. The results are presented here.

43 PARTICLE ACCELERATORS↗

Open Cavity Solutions to the rf in Magnetic Field Problem

It has been observed that breakdown in an 805 MHz pill-box cavity occurs at much lower gradients as an external axial magnetic field is increased. This effect was not observed with on open iris cavity. It is proposed that this effect depends on the relative angles of the magnetic and maximum electric fields: parallel in the pill-box case; at an angle in the open iris case. If so, using an open iris structure with solenoid coils in the irises should perform even better. A lattice, using this principle, is presented, for use in 6D cooling for a Muon Collider. Experimental layouts to test this principle are proposed.

43 PARTICLE ACCELERATORS↗

Statistical Analysis of the Eigenmode Spectrum in the SRF Cavities with Mechanical Imperfections

The superconducting radio frequency (SRF) technology is progressing rapidly over last decades toward high accelerating gradients and low surface resistance making feasible the particle accelerators operation with high beam currents and long duty factors. However, the coherent RF losses due to high order modes (HOMs) excitation becomes a limiting factor for these regimes. In spite of the operating mode, which is tuned separately, the parameters of HOMs vary from one cavity to another due to finite mechanical tolerances during cavities fabrication. It is vital to know in advance the spread of HOM parameters in order to predict unexpected cryogenic losses, overheating of beam line components and to keep stable beam dynamics. In this paper we present the method of generating the unique cavity geometry with imperfections while preserving operating mode frequency and field flatness. Based on the eigenmode spectrum calculation of series of randomly generated cavities we can accumulate the data for the evaluation the HOM statistics. Finally, we describe the procedure for the estimation of the probability of the resonant HOM losses in the SRF resonators. The study of these effects leads to specifications of SC cavity and cryomodule and can significantly impact on the efficiency and reliability of the machine operation

43 PARTICLE ACCELERATORS↗

Linear accelerator accelerating module to suppress back-acceleration of field-emitted particles

A method for the suppression of upstream-directed field emission in RF accelerators. The method is not restricted to a certain number of cavity cells, but requires similar operating field levels in all cavities to efficiently annihilate the once accumulated energy. Such a field balance is desirable to minimize dynamic RF losses, but not necessarily achievable in reality depending on individual cavity performance, such as early Q.sub.0-drop or quench field. The method enables a significant energy reduction for upstream-directed electrons within a relatively short distance. As a result of the suppression of upstream-directed field emission, electrons will impact surfaces at rather low energies leading to reduction of dark current and less issues with heating and damage of accelerator components as well as radiation levels including neutron generation and thus radio-activation.

43 PARTICLE ACCELERATORS↗

Simulations of field emitters and multipacting in PIP-II Single Spoke Resonator Type-2

It has been found in benchmark tests that some Single Spoke Resonator Type-2 (SSR2) cavities have early field emission onset as well as strong multipacting barriers. A longstanding hypothesis is that field-emitted electrons in the high electric field accelerating gap can migrate and ignite multipacting bands in the low electric field regions of the cavity periphery. In this study, we use simulation techniques to examine multipacting behavior in SSR2 cavities from electrons seeded in common field emitter locations. Additionally, we investigated seed locations for areas in SSR2 cavities which may have poor coverage during high pressure water rinsing and compared the multipacting behavior.

43 PARTICLE ACCELERATORS↗

US Contribution to the High Luminosity LHC Upgrade: Focusing Quadrupoles and Crab Cavities

In the early 2000's, the US High Energy Physics community contributing to the Large Hadron Collider (LHC) launched the LHC Accelerator R&D Program (LARP), a long-vision focused R&D program, intended contribute to a quick LHC commissioning and to bring the Nb3Sn and other technologies to a maturity level that would allow applications in HEP machines [1,2]. Around 2015, the technologies developed by LARP, CERN and other institutions were mature enough to allow the spin-off of a major upgrade project to the LHC complex, the High Luminosity LHC (HL-LHC) [3]. This paper will focus on the US contribution to HL-LHC, namely the large-aperture low-β focusing Nb3Sn quadrupoles and the Radio Frequency Dipole (RFD) Crab Cavities, located in close proximity to the ATLAS and CMS experiments. This contribution, called the HL-LHC Accelerator Upgrade Project (HL-LHC AUP), focuses on production of these quadrupoles and cavities by sharing the work among a consortium of US Laboratories (FNAL, LBNL, BNL and SLAC) and Universities and in close connection with the CERN-led HL-LHC Collaboration. The collaboration achieved commonality of specifications and uniformity of performance. Final development of design, construction and first results from the prototypes are described to indicate the status of these critical components for HL-LHC.

43 PARTICLE ACCELERATORS↗

HIGH POWER TEST OF A 3.9 GHZ 5-CELL DEFLECTING-MODE CAVITY IN A CRYOGENIC OPERATION

A 3.9 GHz deflecting mode (S, TM110) cavity has been long used for six-dimensional phase-space beam manipulation tests [1-5] at the A0 Photo-Injector Lab (16 MeV) in Fermilab and their extended applications with vacuum cryomodules are currently planned at the Advanced Superconducting Test Accelerator (ASTA) user facility (> 50 MeV). Despite the successful test results, the cavity, however, demonstrated limited RF performance during liquid nitrogen (LN2) ambient operation that was inferior to theoretical prediction. We have been performing full analysis of the designed cavity by analytic calculation and comprehensive system simulation analysis to solve complex thermodynamics and mechanical stresses. The re-assembled cryomodule is currently under the test with a 50 kW klystron at the Fermilab A0 beamline, which will benchmark the modeling analysis. The test result will be used to design vacuum cryomodules for the 3.9 GHz deflecting mode cavity that will be employed at the ASTA facility for beam diagnostics and phase-space control.

HEP↗

A Method for In-Situ Q₀ Measurements of High-Quality SRF Resonators

Accelerator projects such as LCLS-II naturally require low-loss superconducting (SRF) cavities. Due to strong demand for improving intrinsic quality factor (Q₀), importance of accurate cavity characterization increases. We propose a method to measure Q₀ in situ for an SRF resonator installed in its cryogenic module and connected with a RF feed source via a fixed RF coupler. The method exploits measurements of a response for an SRF resonator fed by an amplitude-modulated signal. Such a signal can be synthesized as a beat-wave composed of two frequencies that are close to the resonant frequency. Analyzing the envelope of the reflected signal, one can find the difference in reflection for the chosen frequencies and use them to compute the intrinsic Q. We also develop the methodology to carry out measurements of Q₀ at the nominal cavity operating voltage. We verified our method in experiments with a room temperature copper resonator and with two SRF resonators including Fermilab’s 650 MHz cavity and JLab’s 1500 MHz cavity.

43 PARTICLE ACCELERATORS↗

External and Internal Reconnection in Two Filament-Carrying Magnetic-Cavity Solar Eruptions

We observe two near-limb solar filament eruptions, one of 2000 February 26 and the other of 2002 January 4. For both we use 195 Angstroms Fe XII images from the Extreme-Ultraviolet (EUV) Imaging Telescope (EIT) and magnetograms from the Michelson Doppler Imager (MDI), both on the Solar and Heliospheric Observatory (SOHO) satellite. For the earlier event we also use soft X-ray telescope (SXT), hard X-ray telescope (HXT), and Bragg Crystal Spectrometer (BCS) data from the Yohkoh satellite, and hard X-ray data from the BATSE experiment on the Compton Gamma Ray Observatory (CGRO). Both events occur in quadrupolar magnetic regions, and both have coronal features that we infer belong to the same magnetic-cavity structures as the filaments. In both cases the cavity and filament first rise slowly at approximately 10 kilometers per second prior to eruption, and then accelerate to approximately 100 kilometers per second during the eruption, although the slow-rise movement for the higher-altitude cavity elements is clearer in the later event. We estimate both filaments and both cavities to contain masses of approximately 10(exp 14-15) g and approximately 10(exp 15-16) g respectively. We consider whether two specific magnetic-reconnection-based models for eruption onset, the tether cutting and the breakout models, are consistent with our observations. In the earlier event soft X-rays from SXT show an intensity increase during the 12-minute interval over whch fast eruption begins, which is consistent with tether-cutting-model predictions. Substantial hard X-rays, however, do not occur until after fast eruption is underway, and so this is a constraint the tether-cutting model must satisfy. During the same 12-minute interval over which fast eruption begins, there are brightenings and topological changes in the corona indicative of high-altitude reconnection early in the eruption, and this is consistent with breakout predictions. In both eruptions, however, the onset of the filament fast-rise phase occurs while overlying cavity-related coronal loops are still evolving from a "closed" state to an "open" state, and our observations of the time evolution of these loops compared to the eruption state in both events are constraints the breakout model must meet. Therefore our findings are consistent with runaway-tether-cutting-type reconnection and fast breakout-type reconnection both occurring early in the fast phase of the February eruption and with both types of reconnection being important in unleashing the explosion, but we are not able to say which, if either, type of reconnection actually triggered the fast phase. We have also found specific constraints that either model, or any other model, must satisfy if correct.

Sterling, Alphonse C.↗

Optimization of Dual Axis Asymmetric Cavity for Energy Recovery Linac

Optimization of the dual axis asymmetric cavity was performed to minimize the ratio of the peak magnetic and electric fields values to the accelerating voltage, to increase the distance between operating and neighbouring modes as well as to reduce the manufacturing cost of the cavity. To reach the goals several solutions have been suggested bringing the ratios to the acceptable values and leading to simplification of the manufacturing of the structure.

Shashkov, Ya. V.↗

Research in Superconducting Radiofrequency Systems

The aim of the program is to transfer our successes in single cell high gradient R&D to multi-cell cavities of advanced shapes. We have also developed a new technique for electropolishing (EP) which is much less expensive than the standard EP technique used at other labs. Our aim is to apply this technique to multi-cell cavities of advanced shapes. The scientific program of this grant was concluded in 2010. An extension of this grant al-lowed us to receive ARRA funding, which we used to improve the helium-liquefier system in Cornell's SRF laboratory. Part of this system had been purchased and installed by another grant. The extension to grant DE-FG02-04ER41354 was proposed to extend this system to sufficient power so that helium can be recovered from SRF-cavity test and simultaneously can be liquefied. This significantly increased the number of cavities we can test per week. This upgrade project was finished in the spring of 2010 and has been in regular use ever since.

43 PARTICLE ACCELERATORS↗

Fabrication and Measurements of 500 MHz Double Spoke Cavity

A 500 MHz β0=1 double spoke cavity has been designed and optimized for a high velocity application such as a compact electron accelerator at the Center for Accelerator Science at Old Dominion University [1] and the fabrication was recently completed at Jefferson Lab. The geometry specific to the double spoke cavity required a variety of tooling and fixtures. Also a number of asymmetric weld joints were expected to make it difficult to maintain minimal geometric deviation from the design. This paper will report the fabrication procedure, resulting tolerance from the design, initial test results and the lessons learned from the first β0=1 double spoke cavity fabrication.

Park, HyeKyoung↗

Highly Accurate Frequency Calculations of Crab Cavities Using the VORPAL Computational Framework

We have applied the Werner-Cary method [J. Comp. Phys. 227, 5200-5214 (2008)] for extracting modes and mode frequencies from time-domain simulations of crab cavities, as are needed for the ILC and the beam delivery system of the LHC. This method for frequency extraction relies on a small number of simulations, and post-processing using the SVD algorithm with Tikhonov regularization. The time-domain simulations were carried out using the VORPAL computational framework, which is based on the eminently scalable finite-difference time-domain algorithm. A validation study was performed on an aluminum model of the 3.9 GHz RF separators built originally at Fermi National Accelerator Laboratory in the US. Comparisons with measurements of the A15 cavity show that this method can provide accuracy to within 0.01% of experimental results after accounting for manufacturing imperfections. To capture the near degeneracies two simulations, requiring in total a few hours on 600 processors were employed. This method has applications across many areas including obtaining MHD spectra from time-domain simulations.

43 PARTICLE ACCELERATORS↗

On-Line Localization of the Lumpectomy Cavity Using Surgical Clips

Purpose: To present an on-line image guidance procedure for external beam accelerated partial breast irradiation based on cone-beam computed tomography (CBCT) imaging of surgical clips; and to estimate the possible clinical target volume (CTV) to planning target volume (PTV) margin reduction allowed by this technique. Methods and Materials: Clips in the CBCT image are detected automatically using in-house software. The treatment couch is translated according to the shift in the clips' center of mass between the planning and CBCT images. Three components for the PTV margin are considered: (1) breathing, (2) surrogate error (i.e., error in cavity position after perfect setup to clips), and (3) residual error (i.e., error arising from the inability to execute a perfect setup to clips due to technological limitations, such as couch travel precision). These factors were input into a standard formula for CTV-to-PTV margin calculation. Results: The average magnitude of clip-based corrections was 7 {+-} 2 mm (10 patients, 44 fractions). After localization, the residual error magnitude was 1.6 {+-} 1.3 mm, justifying an isotropic CTV-to-PTV margin of approximately 6 mm, including breathing and surrogate error. Conclusions: On-line localization of the lumpectomy cavity using surgical clips is technically feasible from the standpoint of equipment, time, and process, making possible a decreased CTV-to-PTV margin for accelerated partial breast irradiation. Because the procedure is exclusively target based, additional monitoring of critical structures may be advisable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗