Search NASA⌕ Search

SEARCH · Search NASA

Results for “Analysis software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Analysis of Performance of Stereoscopic-Vision Software

A team of JPL researchers has analyzed stereoscopic vision software and produced a document describing its performance. This software is of the type used in maneuvering exploratory robotic vehicles on Martian terrain. The software in question utilizes correlations between portions of the images recorded by two electronic cameras to compute stereoscopic disparities, which, in conjunction with camera models, are used in computing distances to terrain points to be included in constructing a three-dimensional model of the terrain. The analysis included effects of correlation- window size, a pyramidal image down-sampling scheme, vertical misalignment, focus, maximum disparity, stereo baseline, and range ripples. Contributions of sub-pixel interpolation, vertical misalignment, and foreshortening to stereo correlation error were examined theoretically and experimentally. It was found that camera-calibration inaccuracy contributes to both down-range and cross-range error but stereo correlation error affects only the down-range error. Experimental data for quantifying the stereo disparity error were obtained by use of reflective metrological targets taped to corners of bricks placed at known positions relative to the cameras. For the particular 1,024-by-768-pixel cameras of the system analyzed, the standard deviation of the down-range disparity error was found to be 0.32 pixel.

Kim, Won↗

The SAS4A/SASSYS-1 Safety Analysis Code System

SAS4A/SASSYS-1 is a software simulation tool used to perform deterministic safety analysis of anticipated events as well as design basis and beyond design basis accidents for advanced nuclear reactors. This software can be used to assess the safety of a prescribed reactor design, but it cannot be used to configure a design to meet targeted performance objectives. Detailed, mechanistic models of steady-state and transient thermal,hydraulic, kinetic, and mechanical phenomena are employed to describe the response of the reactor core, the reactor primary and secondary coolant loops, the reactor control and protection systems and the balance-of-plant to accidents caused by changes in coolantflow, oss of heat rejection, or reactivity insertion. The consequences of single and double-fault accidents can be modeled, including fuel and coolant heating, fuel and cladding mechanical behavior, core reactivity feedbacks, coolant loop performance including natural circulation, and decay heat removal. Analyses are typically terminated upon demonstration of reactor and plant shutdown to permanently coolable conditions or upon violation of design basis margins. The objective of the analysis is to quantify accident consequences as measured by the transient behavior of system performance parameters, such as fuel and cladding temperatures, reactivity, and cladding strain. Originally developed for analysis of sodium cooled reactors with oxide fuel clad by stainless steel, the models In SAS4A/SASSYS-1 were subsequently extended and specialized to metallic fuel clad with advanced alloys and to several other coolant options including lead and LBE. METHOD OF SOLUTION: Each subassembly in the reactor core is represented with single or multiple-pin models. One channel represents one or more fuel pins and many channels are employed for a whole-core representation. Heat transfer in each pin is modeled with a two-dimensional (r/z) heat conduction equation. Single and two-phase coolant thermal-hydraulics are simulated with a unique, one-dimensional (axial) multiple-bubble liquid metal boiling model. The transient fuel and cladding mechanical oehavior models are integrated with fission product production,release, and transport models. UNIQUE FEATURES: The physical models in SAS4AJSASSYS-1 are highly detailed 1umerical representations of reactor accident conditions based on extensive laboratory and test reactor results. The models are specialized to liquid metal (sodium) cooled fast reactors with oxide or metallic fuel clad with stainless steel.

Source record↗

SAS4A/SASSYS-1 VERSION 5.2 SAFETY ANALYSIS CODE SYSTEM

SAS4A/SASSYS-1 is a software simulation tool used to perform deterministic safety analysis of anticipated events as well as design basis and beyond design basis accidents for advanced nuclear reactors. This software can be used to assess the safety of a prescribed reactor design, but it cannot be used to configure a design to meet targeted performance objectives. Detailed, mechanistic models of steady-state and transient thermal, hydraulic, kinetic, and mechanical phenomena are employed to describe the response of the reactor core, the reactor primary and secondary coolant loops, the reactor control and protection systems and the balance-of-plant to accidents caused by changes in coolant flow, oss of heat rejection, or reactivity insertion. The consequences of single and double-fault accidents can be modeled, including fuel and coolant heating, fuel and cladding mechanical behavior, core reactivity feedbacks, coolant loop performance including natural circulation, and decay heat removal. Analyses are typically terminated upon demonstration of reactor and plant shutdown to permanently coolable conditions or upon violation of design basis margins. The objective of the analysis is to quantify accident consequences as measured by the transient behavior of system performance parameters, such as fuel and cladding temperatures, reactivity, and cladding strain. Originally developed for analysis of sodium cooled reactors with oxide fuel clad by stainless steel, the models In SAS4A/SASSYS-1 were subsequently extended and specialized to metallic fuel clad with advanced alloys and to several other coolant options including lead and LBE. METHOD OF SOLUTION: Each subassembly in the reactor core is represented with single or multiple-pin models. One channel represents one or more fuel pins and many channels are employed for a whole-core representation. Heat transfer in each pin is modeled with a two-dimensional (r/z) heat conduction equation. Single and two-phase coolant thermal-hydraulics are simulated with a unique, one-dimensional (axial) multiple-bubble liquid metal boiling model. The transient fuel and cladding mechanical behavior models are integrated with fission product production,release, and transport models. UNIQUE FEATURES: The physical models in SAS4AJSASSYS-1 are highly detailed 1umerical representations of reactor accident conditions based on extensive laboratory and test reactor results. The models are specialized to liquid metal (sodium) cooled fast reactors with oxide or metallic fuel clad with stainless steel.«

Fanning, Thomas↗

SAS4A/SASSYS-1 Verification and Validation Plan for the Versatile Test Reactor

Software verification and validation (V&V) hold an important role in the safety analysis for nuclear facilities. Codes and models utilized in calculations that demonstrate the safety basis as part of a license application or authorization must demonstrate an acceptable pedigree with regard to key critical characteristics that are comprised of the functional and performance requirements of the software. This document describes the methodology for verification and validation of the SAS4A/SASSYS-1 systems-level liquid-metal safety analysis software in support of DOE authorization of the Versatile Test Reactor (VTR). The overall goal of this V&V effort is to demonstrate the suitability of SAS4A/SASSYS-1 for evaluation of safety performance and characterization of safety margins in VTR. To that end, the V&V methodology will be used to demonstrate the adequacy of the component and physical models of SAS4A/SASSYS-1 for the corresponding VTR design elements. This methodology, which has been derived as a generalized approach to the U.S. NRC’s evaluation model development and assessment process (EMDAP) of Regulatory Guide 1.203, entails four high-level activities: software requirements identification, assessment base development, determination of acceptance, and gap closure. The methodology has been generalized to be suitable for both verification and validation of the software for the VTR project. Several high-level engineering analysis quality assurance measures as well as supporting V&V methodology documentation are also described in this document to help support demonstration of software acceptance. To support initial development of the SAS4A/SASSYS-1 V&V basis, existing verification test problems and systems benchmarks are also identified and briefly described in this document.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantitative Uncertainty Analysis for Diffraction

Current software uses a least squares statistical method. For each model parameter, current software yields a point estimate and estimated standard error for each point estimate. In contrast, we have employed a Bayesian approach with sampling algorithm to provide a full posterior probability density function on each model parameter. This yields a different type of solution (probabilistic) with better fidelity. The Quantitative Uncertainty Analysis for Diffraction (QUAD) package returns a matrix of affect model parameters as a function of iteration through the MCMC analysis. QUAD is a Python code that allows for analysis of X-ray and neutron diffraction data to infer the structure of materials with quantifiable certainty. The code uses Bayesian statistics and Markov chain sampling algorithms to create posterior probability distributions on all material structure parameters that are modeled by a researcher. The statistical packages use the open source GSASII project as a library to calculate model diffraction patterns.

Fancher, ChristopherM↗

HEP Software Foundation Community White Paper Working Group - Data Analysis and Interpretation

At the heart of experimental high energy physics (HEP) is the development of facilities and instrumentation that provide sensitivity to new phenomena. Our understanding of nature at its most fundamental level is advanced through the analysis and interpretation of data from sophisticated detectors in HEP experiments. The goal of data analysis systems is to realize the maximum possible scientific potential of the data within the constraints of computing and human resources in the least time. To achieve this goal, future analysis systems should empower physicists to access the data with a high level of interactivity, reproducibility and throughput capability. As part of the HEP Software Foundation Community White Paper process, a working group on Data Analysis and Interpretation was formed to assess the challenges and opportunities in HEP data analysis and develop a roadmap for activities in this area over the next decade. In this report, the key findings and recommendations of the Data Analysis and Interpretation Working Group are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Integrated Sensitivity Analysis Workflow

Sensitivity analysis is a crucial element of rigorous engineering analysis, but performing such an analysis on a complex model is difficult and time consuming. The mission of the DART Workbench team at Sandia National Laboratories is to lower the barriers to adoption of advanced analysis tools through software integration. The integrated environment guides the engineer in the use of these integrated tools and greatly reduces the cycle time for engineering analysis.

97 MATHEMATICS AND COMPUTING↗

Software For Design Of Life-Support Systems

Design Assistant Workstation (DAWN) computer program is prototype of expert software system for analysis and design of regenerative, physical/chemical life-support systems that revitalize air, reclaim water, produce food, and treat waste. Incorporates both conventional software for quantitative mathematical modeling of physical, chemical, and biological processes and expert system offering user stored knowledge about materials and processes. Constructs task tree as it leads user through simulated process, offers alternatives, and indicates where alternative not feasible. Also enables user to jump from one design level to another.

Rudokas, Mary R.↗

Spectator Proton Detection and Reconstruction in Deep Inelastic D(E,EPS) Scattering

A Radial Time Projection Chamber (RTPC) was designed and installed in Jefferson Lab's Hall B as part of the BONuS12 (Barely Off-shell Nucleon Structure) experiment. The goal of BONuS12 is to accurately measure the structure function of the neutron by scattering 11 GeV electrons and detecting them with the CLAS12 spectrometer. Deuterium gas was used as an effective neutron target, and the new RTPC was used to detect low momentum spectator protons. Protons follow a curved path in the 5 Tesla solenoid that is part of CLAS12, ionizing the He-CO2 gas in an annular drift region surrounding the target. These ionization electrons are radially drifted outwards, amplified using cylindrical GEM (Gaseous Electron Multiplication) foils and recorded using readout pads located along the entire outer face of the cylindrical detector. The particle track reconstruction software discussed in detail in this thesis uses the signals from these pads to build tracks, which are reconstructed into the drift region using the arrival times of the signals and the positions of the pads. The proton momentum is measured from the track?s curvature and thus used to extract information about the struck neutron. This thesis introduces the theory of spectator tagging as an effective strategy for measuring neutron structure, by minimizing nuclear effects in the absence of a free neutron target. Along with discussing the many detectors that make up the CLAS12 spectrometer, the RTPC will be covered in detail, along with the tracking software designed to interpret the electronic signals to rebuild the low-momentum particle tracks, and fit them to extract the relevant kinematics. The results of the software, and preliminary analysis will be shown in the final chapter, as well as the discussion of possible improvements which could be made to the tracking software.

Payette, David↗

Selecting an image analysis minicomputer system

Factors to be weighed when selecting a minicomputer system as the basis for an image analysis computer facility vary depending on whether the user organization procures a new computer or selects an existing facility to serve as an image analysis host. Some conditions not directly related to hardware or software should be considered such as the flexibility of the computer center staff, their encouragement of innovation, and the availability of the host processor to a broad spectrum of potential user organizations. Particular attention must be given to: image analysis software capability; the facilities of a potential host installation; the central processing unit; the operating system and languages; main memory; disk storage; tape drives; hardcopy output; and other peripherals. The operational environment, accessibility; resource limitations; and operational supports are important. Charges made for program execution and data storage must also be examined.

Danielson, R.↗

Why Vascular Surgeons and Interventional Radiologists Collaborate or Compete: A Look at Endovascular Stent Placements

PurposeTo understand how cultural differences between vascular surgeons (VSs) and interventional radiologists (IRs) affect their clinical decision making and inter-specialty relationships.MethodsTwenty-four conversational interviews were conducted with IRs and VSs about their approaches to patient care, views of their specialty and others, and solutions to any expressed concerns. Interview transcripts were systematically analyzed to identify and compare key themes according to the constructivist grounded theory and content analysis using NVivo 10 software. These data were supplemented with a retrospective analysis of 3658 endovascular stent placements performed at a large medical academic center over 11 years. Aggregate counts were divided by provider specialty, and trends were assessed via correlation coefficients.ResultsEndovascular stent placements were relatively equally divided between IR and VS over 11 years with some variability from placements by cardiology. IRs tend to lay claim to treatments as masters of procedures, whereas VSs base their claims on being masters of the treated diseases, leading to collaboration in some practices and bitter competition in others. The level of perceived competition was most associated with specialists’ awareness of and appreciation for specialty-specific values rather than differences in practice structure/reimbursement.ConclusionsUnderstanding cultural differences between IRs and VSs is imperative for fostering better collaboration to grow shared territory rather than competing for the same slice of the pie.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Providencia Island High-Level Power System Capacity Expansion Analyses [Slides]

Results of a high level cost-benefit analysis using HOMER Pro software are presented for Providencia Island, Colombia. The analysis focuses on integrating solar photovoltaics (PV) and a battery energy storage system (BESS) into an existing diesel-only remote power system. The analysis uses fuel costs and discount rates provided by the stakeholders and NREL-derived capital cost estimates.

14 SOLAR ENERGY↗

The Analysis Description Language Ecosystem: Latest developments and physics applications

We present latest developments in Analysis Description Language (ADL), a declarative domain-specific language describing the physics algorithm of a HEP data analysis decoupled from software frameworks. Analyses written in ADL can be integrated into any framework for various tasks. ADL is a multipurpose construct with uses ranging from analysis design to preservation, reinterpretation, queries, visualisation, combination, etc. The most advanced infrastructure to execute ADL on events is the CutLang runtime interpreter. Recent technical developments include an automated interface with different data types, generation of the abstract syntax tree, a visualization tool that that auto-converts analysis flows to graphs, incorporation of trained machine learning models and a Jupyter-based plotting tool. We also report physics implications including a large scale LHC analysis implementation and validation effort for beyond the standard model reinterpretation purposes and studies with ATLAS and CMS open data.

Sekmen, Sezen [Kyungpook National Univ., Daegu (Ko↗

Spacelab experiment computer study. Volume 1: Executive summary (presentation)

A quantitative cost for various Spacelab flight hardware configurations is provided along with varied software development options. A cost analysis of Spacelab computer hardware and software is presented. The cost study is discussed based on utilization of a central experiment computer with optional auxillary equipment. Groundrules and assumptions used in deriving the costing methods for all options in the Spacelab experiment study are presented. The groundrules and assumptions, are analysed and the options along with their cost considerations, are discussed. It is concluded that Spacelab program cost for software development and maintenance is independent of experimental hardware and software options, that distributed standard computer concept simplifies software integration without a significant increase in cost, and that decisions on flight computer hardware configurations should not be made until payload selection for a given mission and a detailed analysis of the mission requirements are completed.

Lewis, J. L.↗

SU-C-201-04: Quantification of Perfusion Heterogeneity Based On Texture Analysis for Fully Automatic Detection of Ischemic Deficits From Myocardial Perfusion Imaging

Purpose: Texture-based quantification of image heterogeneity has been a popular topic for imaging studies in recent years. As previous studies mainly focus on oncological applications, we report our recent efforts of applying such techniques on cardiac perfusion imaging. A fully automated procedure has been developed to perform texture analysis for measuring the image heterogeneity. Clinical data were used to evaluate the preliminary performance of such methods. Methods: Myocardial perfusion images of Thallium-201 scans were collected from 293 patients with suspected coronary artery disease. Each subject underwent a Tl-201 scan and a percutaneous coronary intervention (PCI) within three months. The PCI Result was used as the gold standard of coronary ischemia of more than 70% stenosis. Each Tl-201 scan was spatially normalized to an image template for fully automatic segmentation of the LV. The segmented voxel intensities were then carried into the texture analysis with our open-source software Chang Gung Image Texture Analysis toolbox (CGITA). To evaluate the clinical performance of the image heterogeneity for detecting the coronary stenosis, receiver operating characteristic (ROC) analysis was used to compute the overall accuracy, sensitivity and specificity as well as the area under curve (AUC). Those indices were compared to those obtained from the commercially available semi-automatic software QPS. Results: With the fully automatic procedure to quantify heterogeneity from Tl-201 scans, we were able to achieve a good discrimination with good accuracy (74%), sensitivity (73%), specificity (77%) and AUC of 0.82. Such performance is similar to those obtained from the semi-automatic QPS software that gives a sensitivity of 71% and specificity of 77%. Conclusion: Based on fully automatic procedures of data processing, our preliminary data indicate that the image heterogeneity of myocardial perfusion imaging can provide useful information for automatic determination of the myocardial ischemia.

60 APPLIED LIFE SCIENCES↗

Development of a Standard for Verification and Validation of Software Used to Calculate Nuclear System Thermal Fluids Behavior

With the resurgence of nuclear power and increased interest in advanced nuclear reactors as an option to supply abundant energy without the associated greenhouse gas emissions of the more conventional fossil fuel energy sources, there is a need to establish internationally recognized standards for the verification and validation (V&V) of software used to calculate the thermal-hydraulic behavior of advanced reactor designs for both normal operation and hypothetical accident conditions. To address this need, ASME (American Society of Mechanical Engineers) Standards and Certification has established the V&V 30 Committee, under the responsibility of the V&V Standards Committee, to develop a consensus Standard for verification and validation of software used for design and analysis of advanced reactor systems. The initial focus of this committee will be on the V&V of system analysis and computational fluid dynamics (CFD) software for nuclear applications. To limit the scope of the effort, the committee will further limit its focus to software to be used in the licensing of High-Temperature Gas-Cooled Reactors. In this framework, the standard should conform to Nuclear Regulatory Commission (NRC) practices, procedures and methods for licensing of nuclear power plants as embodied in the United States (U.S.) Code of Federal Regulations and other pertinent documents such as Regulatory Guide 1.203, “Transient and Accident Analysis Methods” and NUREG-0800, “NRC Standard Review Plan”. In addition, the standard should be consistent with applicable sections of ASME Standard NQA-1 (“Quality Assurance Requirements for Nuclear Facility Applications (QA)”). This paper describes the general requirements for the V&V Standard, which includes; (a) the definition of the operational and accident domain of a nuclear system that must be considered if the system is to licensed, (b) the corresponding calculational domain of the software that should encompass the nuclear operational and accident domain to be used to study the system behavior for licensing purposes, (c) the definition of the scaled experimental data set required to provide the basis for validating the software, (d) the ensemble of experimental data sets required to populate the validation matrix for the software in question, and (e) the practices and procedures to be used when applying a validation standard. Although this initial effort will focus on software for licensing of High-Temperature Gas Reactors, it is anticipated that the practices and procedures developed for this standard can eventually be extended to other nuclear and non-nuclear applications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutron and X-ray Detectors

The Basic Energy Sciences (BES) X-ray and neutron user facilities attract more than 12,000 researchers each year to perform cutting-edge science at these state-of-the-art sources. While impressive breakthroughs in X-ray and neutron sources give us the powerful illumination needed to peer into the nano- to mesoscale world, a stumbling block continues to be the distinct lag in detector development, which is slowing progress toward data collection and analysis. Urgently needed detector improvements would reveal chemical composition and bonding in 3-D and in real time, allow researchers to watch “movies” of essential life processes as they happen, and make much more efficient use of every X-ray and neutron produced by the source The immense scientific potential that will come from better detectors has triggered worldwide activity in this area. Europe in particular has made impressive strides, outpacing the United States on several fronts. Maintaining a vital U.S. leadership in this key research endeavor will require targeted investments in detector R&D and infrastructure. To clarify the gap between detector development and source advances, and to identify opportunities to maximize the scientific impact of BES user facilities, a workshop on Neutron and X-ray Detectors was held August 1-3, 2012, in Gaithersburg, Maryland. Participants from universities, national laboratories, and commercial organizations from the United States and around the globe participated in plenary sessions, breakout groups, and joint open-discussion summary sessions. Sources have become immensely more powerful and are now brighter (more particles focused onto the sample per second) and more precise (higher spatial, spectral, and temporal resolution). To fully utilize these source advances, detectors must become faster, more efficient, and more discriminating. In supporting the mission of today’s cutting-edge neutron and X-ray sources, the workshop identified six detector research challenges (and two computing hurdles that result from the corresponding increase in data volume) for the detector community to overcome in order to realize the full potential of BES neutron and X-ray facilities. Resolving these detector impediments will improve scientific productivity both by enabling new types of experiments, which will expand the scientific breadth at the X-ray and neutron facilities, and by potentially reducing the beam time required for a given experiment. These research priorities are summarized in the table below. Note that multiple, simultaneous detector improvements are often required to take full advantage of brighter sources. High-efficiency hard X-ray sensors: The fraction of incident particles that are actually detected defines detector efficiency. Silicon, the most common direct-detection X-ray sensor material, is (for typical sensor thicknesses) 100% efficient at 8 keV, 25%efficient at 20 keV, and only 3% efficient at 50 keV. Other materials are needed for hard X-rays. Replacement for 3He for neutron detectors: 3He has long been the neutron detection medium of choice because of its high cross section over a wide neutron energy range for the reaction 3He + n —> 3H + 1H + 0.764 MeV. 3He stockpiles are rapidly dwindling, and what is available can be had only at prohibitively high prices. Doped scintillators hold promise as ways to capture neutrons and convert them into light, although work is needed on brighter, more efficient scintillator solutions. Neutron detectors also require advances in speed and resolution. Fast-framing X-ray detectors: Today’s brighter X-ray sources make time-resolved studies possible. For example, hybrid X-ray pixel detectors, initially developed for particle physics, are becoming fairly mature X-ray detectors, with considerable development in Europe. To truly enable time-resolved studies, higher frame rates and dynamic range are required, and smaller pixel sizes are desirable. High-speed spectroscopic X-ray detectors: Improvements in the readout speed and energy resolution of X-ray detectors are essential to enable chemically sensitive microscopies. Advances would make it possible to take images with simultaneous spatial and chemical information. Very high-energy-resolution X-ray detectors: The energy resolution of semiconductor detectors, while suitable for a wide range of applications, is far less than what can be achieved with X-ray optics. A direct detector that could rival the energy resolution of optics could dramatically improve the efficiency of a multitude of experiments, as experiments are often repeated at a number of different energies. Very high-energy-resolution detectors could make these experiments parallel, rather than serial. Low-background, high-spatial-resolution neutron detectors: Low-background detectors would significantly improve experiments that probe excitations (phonons, spin excitations, rotation, and diffusion in polymers and molecular substances, etc.) in condensed matter. Improved spatial resolution would greatly benefit radiography, tomography, phase-contrast imaging, and holography. Improved acquisition and visualization tools: In the past, with the limited variety of slow detectors, it was straightforward to visualize data as it was being acquired (and adjust experimental conditions accordingly) to create a compact data set that the user could easily transport. As detector complexity and data rates explode, this becomes much more challenging. Three goals were identified as important for coping with the growing data volume from high-speed detectors: Facilitate better algorithm development. In particular, algorithms that can minimize the quantity of data stored. Improve community-driven mechanisms to reduce data protocols and enhance quantitative, interactive visualization tools. Develop and distribute community-developed, detector-specific simulation tools. Aim for parallelization to take advantage of high-performance analysis platforms. Improved analysis work flows: Standardize the format of metadata that accompanies detector data and describes the experimental setup and conditions. Develop a standardized user interface and software framework for analysis and data management. The diversity of detector improvements required is necessarily as broad as the range of scientific experimentation at BES facilities. This workshop identified a variety of avenues by which detector R&D can enable enhanced science at BES facilities. The Research Directions listed above will be addressed by focused R&D and detector engineering, both of which require specialized infrastructure and skills. While U.S. leadership in neutron and X-ray detectors lags behind other countries in several areas, significant talent exists across the complex. A forum of technical experts, facilities management, and BES could be a venue to provide further definition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Extensible Reduced Order Model Builder for Simulation and Modeling

REVEAL is a software framework for building reduced order models (surrogate models) for high fidelity complex scientific simulations. REVEAL is designed to do reduced order modeling and sensitivity analysis for scientific simulations. REVEAL incorporates a range of sampling and regression methods. It provides complete user environment and is adaptable to new simulators, runs jobs on any computing platform of choice, automatically post processes simulation results and provides a range of data analysis tools. The software is generic and can easily be extended to incorporate new methods, simulators.

Source record↗